Pre-Regulator Module PR036A480T012FP vicorpower.com Rev. 1.1 Page 1 of 13
Product Grade Temperatures (°C)
Grade Operating Storage
T = -40 to +100 -40 to +125
Baseplate
F= Slotted flange
T= Transverse heat sink[a]
[a]Contact factory
PRMTM Regulator
Product Overview
The VI BRICK Pre-Regulator Module is a very efficient non-isolated regulator specifically
designed to provide a controlled Factorized Bus distribution voltage for powering
downstream VI BRICK Voltage Transformation Modules. In combination, VI BRICK PRMs
and VTMsTM form a complete DC-DC converter subsystem offering all of the unique
benefits of Vicor’s Factorized Power Architecture (FPA): high density and efficiency; low
noise operation; architectural flexibility; extremely fast transient response; elimination of
bulk capacitance at the Point-of-Load (POL); in a thermally enhanced package.
Applications
Solid state lighting
Stadium displays
Industrial controls
Avionics
Underseas
RF Amplifiers
Microprocessor and DSP
requiring fast response
100°C baseplate operation
Vin range: 18 – 60 Vdc
Factorized Power
High density: up to 156 W/in3
Small footprint: 1.64 and 2.08 in2
Height above board: 0.37 in (9.5 mm)
Low weight: 1.07 oz (30.4 g)
ZVS buck-boost regulator
Typical efficiency: 95%
1.35 MHz switching frequency
Low noise operation
Architectural flexibility
Lead free wave solder compatible
Agency approvals
Features
PR 036 A 480 T 012 F P
Output
Voltage
Designator
(=VOUT x10)
Output
Power
Designator
(=POUT /10)
Part Numbering
Pre-Regulator
Module
Input
Voltage
Designator
Package
Size
Pin Style
P = Through hole
Size:
1.91 x 1.09 x 0.37 in
48,6 x 27,7 x 9,5 mm
Pre-Regulator Module PR036A480T012FP vicorpower.com Rev. 1.1 Page 2 of 13
Parameter Values Unit Notes
+In to -In -1.0 to 85.0 Vdc
PC to -In -0.3 to 6.0 Vdc
PR to -In -0.3 to 9.0 Vdc
IL to -In -0.3 to 6.0 Vdc
VC to -In -0.3 to 18.0 Vdc
+Out to -Out -0.3 to 59 Vdc
SC to -Out -0.3 to 3.0 Vdc
VH to -Out -0.3 to 9.5 Vdc
OS to -Out -0.3 to 9.0 Vdc
CD to -Out -0.3 to 9.0 Vdc
SG to -Out 100 mA
Continuous output current 2.5 Adc
Continuous output power 120 W
Operating temperature -40 to +100 °C T-Grade; baseplate
Storage temperature -40 to +125 °C T-Grade
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
Absolute Maximum Ratings
SPECIFICATIONS
Parameter Min Typ Max Unit Notes
Input voltage range 18 36 60 Vdc
Input dV/dt 1 V/µs
Input undervoltage turn-on 17 17.6 Vdc
Input undervoltage turn-off 15.2 15.9 Vdc
Input overvoltage turn-on 60 62 Vdc
Input overvoltage turn-off 63 65 Vdc
Input quiescent current 0.5 1 mA PC low
Input current 3.5 Adc
Input reflected ripple current 586 mA p-p See Figures 3 & 4
No load power dissipation 3 6 W
Internal input capacitance 5 µF Ceramic
Recommended external input capacitance 100 µF See Figure 4 for input filter circuit.
Source impedance dependent
Input Specifications (Conditions are at 36 Vin, 48 Vf [a], full load, and 25°C ambient unless otherwise specified)
Note: Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any other conditions
in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability.
[a] Vf is factorized bus voltage (see Figure 15).
Pre-Regulator Module PR036A480T012FP vicorpower.com Rev. 1.1 Page 3 of 13
SPECIFICATIONS (CONT.)
Figure 3 Input reflected ripple current
+IN
–IN
100 μF
Al-Electrolytic
Reflected
Ripple
Measurement 2.37 kΩ
+ OUT
– OUT
10 A
PRM
VH
SC
SG
OS
NC
CD
VC
PC
TM
IL
NC
PR
+IN +OUT
-OUT
-IN
Figure 4 Input filter capacitor recommendation
INPUT WAVEFORMS
Figure 1 Vf and PC response from power up Figure 2 Vf turn-on waveform with inrush current – PC enabled
[a] See Input Fuse Recommendations section
[a]
Pre-Regulator Module PR036A480T012FP vicorpower.com Rev. 1.1 Page 4 of 13
Parameter Min Typ Max Unit Note
Output voltage range 26 48 55 Vdc Factorized Bus voltage (Vf) set by ROS
Output power 0 120 W
Output current 0 2.5 Adc
DC current limit 2.6 2.96 3.3 Adc ILpin floating
Average short circuit current 1.25 A Auto recovery
Set point accuracy 1.5 %
Line regulation 0.1 0.2 % Low line to high line
Load regulation 0.1 0.2 % No CD resistor
Load regulation (at VTM output) 1.0 2.0 % Adaptive Loop
Current share accuracy 5 10 %
Efficiency
Full load 95 % See Figure 5,6 & 7
Output overvoltage set point 56 59.4 Vdc
Output ripple voltage
No external bypass 1.51 3.5 % Factorized Bus, see Figure 12
With 10 µF capacitor 0.42 1.0 % Factorized Bus, See Figure 13
Switching frequency 1.26 1.35 1.46 MHz Fixed frequency - across entire operating range
Output turn-on delay
From application of power 74 250 ms See Figure 1
From PC pin high 100 µs See Figure 2
Internal output capacitance 5 µF Ceramic
Factorized Bus capacitance 47 µF
Output Specifications (Conditions are at 36 Vin, 48 Vf [a], full load, and 25°C ambient unless otherwise specified)
SPECIFICATIONS (CONT.)
Pre-Regulator Module PR036A480T012FP vicorpower.com Rev. 1.1 Page 5 of 13
SPECIFICATIONS (CONT.)
Efficiency vs. Output Current
75.
80
85
90
95
100
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Output Current (A)
Efficiency (%)
18 V
36 V
60 V
Vin
Figure 5 Efficiency vs. output current at 48 Vf
Efficiency vs. Output Current
65
70
75
80
85
90
95
100
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Output Current (A)
Efficiency (%)
18 V
36 V
60 V
Vin
Figure 6 Efficiency vs. output current at 36 Vf
OUTPUT WAVEFORMS
Efficiency vs. Output Current
65
70
75
80
85
90
95
100
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Output Current (A)
Efficiency (%)
18 V
36 V
60 V
Vin
Figure 7 Efficiency vs. output current at 26 Vf
Pre-Regulator Module PR036A480T012FP vicorpower.com Rev. 1.1 Page 6 of 13
SPECIFICATIONS (CONT.)
OUTPUT WAVEFORMS
Figure 9 — Transient response; PRM alone 18 Vin, 0-2.5-0 A no load
capacitance, local loop
Figure 8 — Transient response; PRM alone 36 Vin, 0-2.5-0 A, no load
capacitance, local loop
Figure 10 Transient response; PRM alone 60 Vin, 0-2.5-0 A no load
capacitance, local loop.
Figure 11 PC during fault – frequency will vary as a function of line voltage
Figure 12 Output ripple full load no bypass capacitance. Vf = 48 Vdc Figure 13 Output ripple full load 10 µF bypass capacitance. Vf = 48 Vdc
Pre-Regulator Module PR036A480T012FP vicorpower.com Rev. 1.1 Page 7 of 13
SPECIFICATIONS (CONT.)
Parameter Min Typ Max Unit Notes
MTBF
MIL-HDBK-217F 2.2 Mhrs 25°C, GB
Agency approvals CTÜVus UL/CSA 60950-1, EN60950-1
CE Mark Low voltage directive
RoHS Complies wih RoHS
Mechanical parameters See Mechanical Drawings, Figures 19 & 20
Weight 1.07/30,4 oz/g
Dimensions
Length 1.91/48,6 in/mm
Width 1.09/27,7 in/mm
Height 0.37/9,5 in/mm
Thermal
Over temperature shutdown 130 135 140 °C junction temperature
Thermal capacity 23.8 Ws/°C
Baseplate to ambient 8.8 °C/W
Baseplate to ambient; 1000 LFM 3.0 °C/W
Baseplate to sink; flat, greased surface 0.40 °C/W
Baseplate to sink; thermal pad 0.36 °C/W
General Specifications
Parameter Min Typ Max Unit Notes
VC (VTM Control)
Pulse width 81218ms
Peak voltage 12 14 18 V Referenced to –Out
PC (Primary Control)
DC voltage 4.8 5.0 5.2 Vdc Referenced to –In
Module disable voltage 2.3 2.4 Vdc Referenced to –In
Module enable voltage 2.5 2.6 Vdc
Disable hysteresis 100 mV
Source only after start up; not to be used for
Current limit 1.75 1.90 mA aux. supply; 100 kΩminimum load
impedance to assure start up.
Enable delay time 100 µs
Disable delay time 1 µs
IL (Current Limit Adjust)
Voltage 1 V
Accuracy ± 15 % Based on DC current limit set point
PR (Parallel Port)
Voltage 0.5 3.5 V Referenced to SG; See description Page 8
Source current 1 mA
External capacitance 100 pF
VH (Auxiliary Voltage) Typical internal bypass C=0.1 µF
Range 8.7 9.0 9.3 Vdc Maximum external C=0.1 µF, referenced to SG
Regulation 0.04 %/mA
Current 5 mA p
SC (Secondary Control)
Voltage 1.23 1.24 1.25 Vdc Referenced to SG
Internal capacitance 0.22 µF
External capacitance 0.7 µF
OS (Output Set)
Set point accuracy ± 1.5 % Includes 1% external resistor
Reference offset ± 4 mV
CD (Compensation Device)
External resistance 20 ΩOmit resistor for regulation at output of PRM
Auxiliary Pins
Pre-Regulator Module PR036A480T012FP vicorpower.com Rev. 1.1 Page 8 of 13
PIN / CONTROL FUNCTIONS
Figure 14 — VI BRICK PRM pin configuration (viewed from pin side).
+In / -In DC Voltage Ports
The VI BRICK maximum input voltage should not be exceeded. PRMs have
internal over / undervoltage lockout functions that prevent operation
outside of the specified input range. PRMs will turn on when the input
voltage rises above its undervoltage lockout. If the input voltage exceeds
the overvoltage lockout, PRMs will shut down until the overvoltage fault
clears. PC will toggle indicating an out of bounds condition.
+Out / -Out Factorized Voltage Output Ports
These ports provide the Factorized Bus voltage output. The –Out port is
connected internally to the –In port through a current sense resistor. The
PRM has a maximum power and a maximum current rating and is
protected if either rating is exceeded. Do not short –Out to –In.
VC – VTM Control
The VTM Control (VC) port supplies an initial VCC voltage to downstream
VTMs, enabling the VTMs and synchronizing the rise of the VTM output
voltage to that of the PRM. The VC port also provides feedback to the
PRM to compensate for voltage drop due to the VTM output resistance.
The PRM’s VC port should be connected to the VTM VC port. A PRM VC
port can drive a maximum of two (2) VTM VC ports.
PC – Primary Control
The PRM voltage output is enabled when the PC pin is open circuit
(floating). To disable the PRM output voltage, the PC pin is pulled low.
Open collector optocouplers, transistors, or relays can be used to control
the PC pin. When using multiple PRMs in a high power array, the PC ports
must be tied together to synchronize their turn on. During an abnormal
condition the PC pin will pulse (Fig.11) as the PRM initiates a restart cycle.
This will continue until the abnormal condition is rectified. The PC should
not be used as an auxiliary voltage supply, nor should it be switched at a
rate greater than 1 Hz.
TM – Factory Use Only
IL – Current Limit Adjust
The PRM has a preset, maximum, current limit set point. The IL port may
be used to reduce the current limit set point to a lower value. See “adjust-
ing current limits” on page 11.
PR – Parallel Port
The PR port signal, which is proportional to the PRM output power,
supports current sharing of two PRMs. To enable current sharing, PR ports
should be interconnected. Bypass capacitance should be used when
interconnecting PR ports and steps should be taken to minimize coupling
noise into the interconnecting bus. Terminate this port with a 10 k
equivalent resistance to SG, e.g. 10 k for a single PRM, 20 k each for 2
PRMs in parallel, 30 k each for 3 PRMs in parallel etc.. Please consult Vicor
Applications Engineering regarding additional considerations when
paralleling more than two PRMs.
VH – Auxiliary Voltage
VH is a gated (e.g. mirrors PC), non-isolated, nominally 9 Volt, regulated
DC voltage (see “Auxiliary Pins” specifications, on Page 7) that is
referenced to SG. VH may be used to power external circuitry having a
total current consumption of no more than 5 mA under either transient or
steady state conditons including turn-on.
SC – Secondary Control
The load voltage may be controlled by connecting a resistor or voltage
source to the SC port referenced to SG. The slew rate of the output
voltage may be controlled by controlling the rate-of-rise of the voltage at
the SC port (e.g., to limit inrush current into a capacitive load).
SG – Signal Ground
This port provides a low inductance Kelvin connection to –In and should be
used as reference for the OS, CD, SC,VH and IL ports.
OS – Output Set
The application-specific value of the Factorized Bus voltage (Vf) is set by
connecting a resistor between OS and SG. Resistor value selection is shown
in Table 1 on Page 9, and described on Page 10. If no resistor is connected,
the PRM output will be approximately one volt. If set resistor is not collo-
cated with the PRM, a local bypass capacitor of ~200 pF may be required.
CD – Compensation Device
Adaptive Loop control is configured by connecting an external resistor
between the CD port and SG. Selection of an appropriate resistor value
(see Equation 2 on Page 10 and Table 1 on Page 9) configures the PRM to
compensate for voltage drops in the equivalent output resistance of the
VTM and the PRM-VTM distribution bus. If no resistor is connected to CD,
the PRM will be in Local Loop mode and will regulate the
+Out / –Out voltage to a fixed value.
Pre-Regulator Module PR036A480T012FP vicorpower.com Rev. 1.1 Page 9 of 13
APPLICATION INFORMATION
Overview of Adaptive Loop Compensation
Adaptive Loop compensation, illustrated in Figure 15, contributes to the
bandwidth and speed advantage of Factorized Power. The PRM moni-
tors its output current and automatically adjusts its output voltage to
compensate for the voltage drop in the output resistance of the VTM.
ROS sets the desired value of the VTM output voltage, Vout; RCD is set to
a value that compensates for the output resistance of the VTM (which,
ideally, is located at the point of load). For selection of ROS and RCD,
refer to Table 1 below or Page 10.
The VI BRICK’s bi-directional VC port :
1. Provides a wake up signal from the PRM to the VTM that
synchronizes the rise of the VTM output voltage to that of the PRM.
2. Provides feedback from the VTM to the PRM to enable the PRM to
compensate for the voltage drop in VTM output resistance, RO.
L
O
A
D
Factorized
Bus (Vf)
Vo = VL ± 1.0%
(Io•Ro)
K
Vf = VL +
K
Vin
ROS
RCD
PRM
VH
SC
SG
OS
NC
CD
VC
PC
TM
IL
NC
PR
+IN +OUT
-OUT
-IN
VTM
+IN +OUT
-OUT
+OUT
-OUT
-IN
TM
VC
PC
Figure 15 — With Adaptive Loop control, the output of the VTM is regulated over the load current range with only a single interconnect between the PRM and
VTM and without the need for isolation in the feedback path.
Desired Load Voltage (Vdc) VI BRICK VTM P/N(1) Max VTM Output Current (A)(2) ROS (kΩ)(3) RCD (Ω)(3)
1.0 VT048A015T100FP 100 3.57 26.1
1.2 VT048A015T100FP 100 2.94 32.4
1.5 VT048A015T100FP 100 2.37 39.2
1.8 VT048A020T080FP 80 2.61 35.7
2.0 VT048A020T080FP 80 2.37 39.2
3.0 VT048A030T070FP 70 2.37 39.2
3.3 VT048A040T050FP 50 2.89 32.6
5.0 VT048A060T040FP 40 2.87 33.2
8.0 VT048A080T030FP 30 2.37 32.9
9.6 VT048A096T025FP 25 2.37 32.9
10 VT048A120T025FP 25 2.86 32.9
12 VT048A120T025FP 25 2.37 39.2
15 VT048A160T015FP 15 2.49 37.4
24 VT048A240T012FP 12.5 2.37 39.2
28 VT048A320T009FP 9.4 2.74 35.7
36 VT048A480T006FP 6.3 3.16 30.1
48 VT048A480T006FP 6.3 2.37 39.2
Table 1 — Configure the VI BRICK PRM/VTM for the desired output voltage.
Note:
(1) See Table 2 on page 10 for nominal Vout range and K factors.
(2) See “PRM output power vs. VTM output power” on Page 11
(3) 1% precision resistors recommended
Pre-Regulator Module PR036A480T012FP vicorpower.com Rev. 1.1 Page 10 of 13
APPLICATION INFORMATION
L
O
A
D
Factorized
Bus (Vf)
(IL•Ro)
K
Vf = VL +
K
Vin
R
OS
R
CD
0.4 μH
PRM-AL
VH
SC
SG
OS
NC
CD
VC
PC
TM
IL
NC
PR
+IN +OUT
-OUT
-IN
VTM
+IN +OUT
-OUT
+OUT
-OUT
-IN
TM
VC
PC
Output Voltage Setting with Adaptive Loop
The equations for calculating ROS and RCD to set a VTM output
voltage are:
93100
ROS =(VL• 0.8395 ) 1(1)
K
RCD =91238 + 1 (2)
ROS
VL= Desired load voltage
VOUT = VTM output voltage
K = VTM transformation ratio
(available from appropriate VTM data sheet)
Vf= PRM output voltage, the Factorized Bus (see Figure 16)
RO= VTM output resistance
(available from appropriate VTM data sheet)
IL= Load Current
(actual current delivered to the load)
Output Voltage Trimming (optional)
After setting the output voltage from the procedure above the output
may be margined down (26 Vf min) by a resistor from SC-SG using this
formula:
RdΩ=10000 Vfd
Vfs - Vfd
Where Vfd is the desired factorized bus and Vfs is the set factorized bus.
A low voltage source can be applied to the SC port to margin the load
voltage in proportion to the SC reference voltage.
An external capacitor can be added to the SC port as shown in Figure 16
to control the output voltage slew rate for soft start.
Figure 16 — Adaptive Loop compensation with soft start using the SC port.
Nominal Vout VTM
Range (Vdc) K Factor
0.8
1.6 1/32
1.1
2.2 1/24
1.6
3.3 1/16
2.2
4.4 1/12
3.3
6.6 1/8
4.3
8.8 1/6
6.5
13.4 1/4
8.7
17.9 1/3
13.0
26.9 1/2
17.4
36.0 2/3
26.0
54.0 1
Table 2 — 048 input series VTM K factor selection guide
Pre-Regulator Module PR036A480T012FP vicorpower.com Rev. 1.1 Page 11 of 13
APPLICATION NOTES
OVP – Overvoltage Protection
The output Overvoltage Protection set point of the PR036A480T012FP is
factory preset for 56 V. If this threshold is exceeded the output shuts down
and a restart sequence is initiated, also indicated by PC pulsing. If the
condition that causes OVP is still present, the unit will again shut down.
This cycle will be repeated until the fault condition is removed. The OVP set
point may be set at the factory to meet unique high voltage requirements.
PRM Output Power Versus VTM Output Power
As shown in Figure 17, the PR036A480T012FP is rated to deliver 2.5 A
maximum, when it is delivering an output voltage in the range from 26 V
to 48 V, and 120 W, maximum, when delivering an output voltage in the
range from 48 V to 55 V. When configuring a PRM for use with a specific
VTM, refer to the appropriate VTM data sheet. The VTM input power can
be calculated by dividing the VTM output power by the VTM efficiency
(available from the VTM data sheet). The input power required by the VTM
should not exceed the output power rating of the PRM.
The Factorized Bus voltage should not exceed an absolute limit of 55 V,
including steady state, ripple and transient conditions. Exceeding this limit
may cause the internal OVP set point to be exceeded.
Parallel Considerations
The PR port is used to connect two PRMs in parallel to form a higher
power array. When configuring arrays, PR port interconnection terminating
impedance is 10 k to SG. See note Page 8 and refer to Application Note
AN002. Additionally one PRM should be designated as the master while all
other PRMs are set as slaves by shorting their SC pin to SG. The PC pins
must be directly connected (no diodes) to assure a uniform start up
sequence. Consult Vicor applications engineering for applications requiring
more than two PRMs.
Adjusting Current Limit
The current limit can be lowered by placing an external resistor between
the ILand SG ports (see Figure 18 for resistor values) . With the ILport
open-circuit, the current limit is preset to be within the range specified in
the output specifications table on Page 4.
Input Fuse Recommendations
A fuse should be incorporated at the input to the PRM, in series with the
+In port. A fast acting fuse, NANO2 FUSE 451/453 Series 10 A 125 V, or
equivalent, may be required to meet certain safety agency Conditions of
Acceptability. Always ascertain and observe the safety, regulatory, or other
agency specifications that apply to your specific application. For agency
approvals and fusing conditions, click on the link below:
http://www.vicorpower.com/technical_library/technical_documentation/quality_and_
certification/safety_approvals/
Product Safety Considerations
If the input of the PRM is connected to SELV or ELV circuits, the output of
the PRM can be considered SELV or ELV respectively.
If the input of the PRM is connected to a centralized DC power system
where the working or float voltage is above SELV, but less than or equal to
75 V, the input and output voltage of the PRM should be classified as a
TNV-2 circuit and spaced 1.3 mm from SELV circuitry or accessible
conductive parts according to the requirements of UL60950-1,
CSA 22.2 60950-1, EN60950-1, and IEC60950-1.
Application Notes
For PRM and VI BRICK application notes on soldering, board layout, and
system design please click on the link below:
http://www.vicorpower.com/technical_library/application_information/
Applications Assistance
Please contact Vicor Applications Engineering for assistance,
1-800-927-9474, or email at apps@vicorpower.com.
Desired PRM Output Current Limit (A)
1
10
100
0 0.5 1 1.5 2 2.5 3
Resistance (kΩ)
Figure 18 — Calculated external resistor value for adjusting current limit, actual
value may vary.
26 30 34 38 42 46 50 54
Factorized Bus Voltage (Vf)
2.30
2.35
2.40
2.45
2.50
2.55
Current (A)
28 32 36 40 44 48 52
2.25
2.20
2.15
60
20
~
~
0
22 24 56 58
Safe Operating Area
Figure 17 — PR036A480T012FP rating based on Factorized Bus voltage
Pre-Regulator Module PR036A480T012FP vicorpower.com Rev. 1.1 Page 12 of 13
Figure 19 Module outline
Figure 20 PCB mounting specifications
MECHANICAL DRAWINGS
Recommended PCB Pattern
(Component side shown)
Baseplate - Slotted Flange Heat Sink (Transverse)
Pre-Regulator Module PR036A480T012FP vicorpower.com Rev. 1.1 5/08
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in
normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application
or maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original
purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING,
BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty,
the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products
returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning
the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this
warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve
reliability, function, or design. Vicor does not assume any liability arising out of the application or use of any product or
circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not
recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten
life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes
all risks of such use and indemnifies Vicor against all damages.
Vicor’s comprehensive line of power solutions includes high density AC-DC and
DC-DC modules and accessory components, fully configurable AC-DC and DC-DC
power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for
its use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or
malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available
upon request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intel-
lectual Property Department.
The products described on this data sheet are protected by the following U.S. Patents Numbers:
5,945,130; 6,403,009; 6,710,257; 6,788,033; 6,940,013; 6,969,909; 7,038,917; 7,154,250; 7,166,898;
7,187,263; 7,202,646; 7,361,844; 7,368,957; RE40,072; D496,906; D506,438; D509,472; and for use under
U.S. Pat. Nos. 6,975,098 and 6,984,965