Standard AC Output Modules Features Rugged construction 4000 volts of optical isolation between the field devices and the control logic (transient) Zero voltage turn-on and zero current turn-off Description AC output modules are used for controlling or switching AC loads. Each module providesup to 4000 volts (transient) of optical isolation between the field devices and the control logic. With the exception of the OAC5A5 module, all AC output modules are equivalent to a single pole, single throw, normally open contact (FORM A, SPST-NO, Make). The OAC5A5 is equivalent to a single pole, single throw, normally closed contact (FORM B, SPST-NC, Break). All AC output modules feature zero voltage turn-on and zero current turn-off. Typical uses and applications for AC output modules include switching the following loads: * Relays * Solenoids * Motor starters * Heaters * Lamps or indicators Standard AC Output Modules OAC5 Module Part Numbers Part Description OAC5 AC Output 12-140 VAC, 5 VDC Logic OAC5A AC Output 24-280 VAC, 5 VDC Logic OAC5H* AC Output 24-280 VAC, 5 VDC Logic, higher current rating OAC5A5 AC Output 24-280 VAC, 5 VDC Logic, NC OAC15 AC Output 12-140 VAC, 15 VDC Logic OAC15A AC Output 24-280 VAC, 15 VDC Logic OAC24 AC Output 12-140 VAC, 24 VDC Logic OAC24A AC Output 24-280 VAC, 24 VDC Logic OAC24H* AC Output 24-280 VAC, 24 VDC Logic, higher current rating (c) 2006-2012 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. DATA SHEET Opto 22 * 43044 Business Park Drive * Temecula, CA 92590-3614 * www.opto22.com SALES 800-321-6786 * 951-695-3000 * FAX 951-695-3095 * sales@opto22.com * SUPPORT 800-835-6786 * 951-695-3080 * FAX 951-695-3017 * support@opto22.com Form 449-120920 * Not UL approved PAGE 1 Standard AC Output Modules Specifications Form 449-120920 DATA SHEET Standard AC Output Modules General PAGE 2 One Cycle Surge 80 amps peak Peak Repetitive Voltage 500 Volts Operating Ambient Temperature -30 to 70 C Isolation, Input-to-Output (Transient) 4,000 Vrms Minimum Load Current 20 milliamps Operating Frequency 25-65 Hz Turn-on Time 1/2 cycle maximum-zero voltage Turn-off Time 1/2 cycle maximum-zero current DV/DT - Off-State 200 volts/microseconds DV/DT - Commutating Snubbed for rated 0.5 power factor load Output Voltage Drop Maximum Peak 1.6 volts Off-State Leakage @ Nominal Voltage - 60 Hz 5 milliamps rms 2.5 milliamps rms for OAC5A OAC15A, and OAC24A @120 VAC Module Specifications Units OAC5 OAC5A OAC5H OAC5A5 (NC) OAC153 OAC15A3 OAC243 OAC24A3 OAC24H3 Line Voltage - Nominal VAC 120 240 240 120/240 120 240 120 240 240 Operating Voltage Range VAC 12-140 24-280 24-280 24-280 12-140 24-280 12-140 24-280 24-280 Current Rating @ 45 C Ambient @ 70 C Ambient amps amps 3 2 3 2 4 2 3 2 3 2 3 2 3 2 3 2 4 2 UL Motor Load Rating amps 1.5 1.5 -- * 1.5 1.5 1.5 1.5 1.5 -- 1 Logic Voltage - Nominal VDC 5 5 5 5 15 15 24 24 24 Logic Voltage Range (Vcc)2 VDC 2.5-8 2.5-8 2.5-8 2.5-8 9-16 9-16 18-32 18-32 18-32 Logic Pickup Voltage1 VDC 2.5 2.5 2.5 2.5 9 9 18 18 18 Logic Dropout Voltage VDC 1 1 1 1 1 1 1 1 1 Logic Input Current-@ Normal Logic Voltage (Iout in schematic diagram) mA 12 12 12 12 15 15 18 18 18 Control Resistance (Rc in schematic diagram) Ohms 220 220 220 220 1K 1K 2.2K 2.2K 2.2K 1 Not UL approved 2 Module only 3 Not for use with Opto 22 brains Opto 22 * 43044 Business Park Drive * Temecula, CA 92590-3614 * www.opto22.com SALES 800-321-6786 * 951-695-3000 * FAX 951-695-3095 * sales@opto22.com * SUPPORT 800-835-6786 * 951-695-3080 * FAX 951-695-3017 * support@opto22.com (c) 2006-2012 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. Standard AC Output Modules Dimensions Standard AC Output Modules Form 449-120920 (c) 2006-2012 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. DATA SHEET Opto 22 * 43044 Business Park Drive * Temecula, CA 92590-3614 * www.opto22.com SALES 800-321-6786 * 951-695-3000 * FAX 951-695-3095 * sales@opto22.com * SUPPORT 800-835-6786 * 951-695-3080 * FAX 951-695-3017 * support@opto22.com PAGE 3 Standard AC Output Modules Standard AC Output Modules Connections Form 449-120920 DATA SHEET Schematics PAGE 4 Opto 22 * 43044 Business Park Drive * Temecula, CA 92590-3614 * www.opto22.com SALES 800-321-6786 * 951-695-3000 * FAX 951-695-3095 * sales@opto22.com * SUPPORT 800-835-6786 * 951-695-3080 * FAX 951-695-3017 * support@opto22.com (c) 2006-2012 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. More About Opto 22 Products Opto 22 develops and manufactures reliable, flexible, easy-touse hardware and software products for industrial automation, energy management, remote monitoring, and data acquisition applications. OptoEMU Energy Management System The easy-to-use OptoEMU Sensor monitors electrical energy use in your facility and delivers detailed, real-time data you can see and analyze. The Sensor can monitor energy data from pulsing meters, electrical panels or subpanels, and equipment. View energy data online using a software service or incorporate the data into your control system for complete energy management. SNAP PAC System Designed to simplify the typically complex process of selecting and applying an automation system, the SNAP PAC System consists of four integrated components: * SNAP PAC controllers * PAC ProjectTM Software Suite * SNAP PAC brains * SNAP I/OTM SNAP PAC Controllers Programmable automation controllers (PACs) are multifunctional, modular controllers based on open standards. Opto 22 has been manufacturing PACs for over two decades. The standalone SNAP PAC S-series and the rack-mounted SNAP PAC R-series both handle a wide range of digital, analog, and serial functions for data collection, remote monitoring, process control, and discrete and hybrid manufacturing. SNAP PACs are based on open Ethernet and Internet Protocol (IP) standards, so you can build or extend a system easily, without the expense and limitations of proprietary networks and protocols. PAC Project Software Suite Opto 22's PAC Project Software Suite provides full-featured, cost-effective control programming, HMI (human machine interface) development and runtime, OPC server, and database connectivity software for your SNAP PAC System. Control programming includes both easy-to-learn flowcharts and optional scripting. Commands are in plain English; variables and I/O point names are fully descriptive. PAC Project Basic offers control and HMI tools and is free for download on our website, www.opto22.com. PAC Project Professional, available for separate purchase, adds OptoOPCServer, OptoDataLink, options for controller redundancy or segmented networking, and support for legacy Opto 22 serial misticTM I/O units. SNAP PAC Brains While SNAP PAC controllers provide central control and data distribution, SNAP PAC brains provide distributed intelligence for I/O processing and communications. Brains offer analog, digital, and serial functions, including thermocouple linearization; PID loop control; and optional high-speed digital counting (up to 20 kHz), quadrature counting, TPO, and pulse generation and measurement. SNAP I/O I/O provides the local connection to sensors and equipment. Opto 22 SNAP I/O offers 1 to 32 points of reliable I/O per module, depending on the type of module and your needs. Analog, digital, and serial modules are all mixed on the same mounting rack and controlled by the same processor (SNAP PAC brain or rack-mounted controller). Quality Founded in 1974, Opto 22 has established a worldwide reputation for high-quality products. All are made in the U.S.A. at our manufacturing facility in Temecula, California. Because we do no statistical testing and each part is tested twice before leaving our factory, we can guarantee most solid-state relays and optically isolated I/O modules for life. Free Product Support Opto 22's California-based Product Support Group offers free, comprehensive technical support for Opto 22 products. Our staff of support engineers represents decades of training and experience. Support is available in English and Spanish by phone or email, Monday-Friday, 7 a.m. to 5 p.m. PST. Additional support is always available on our website: how-to videos, OptoKnowledgeBase, self-training guide, troubleshooting and user's guides, and OptoForums. In addition, hands-on training is available for free at our Temecula, California headquarters, and you can register online. Purchasing Opto 22 Products Opto 22 products are sold directly and through a worldwide network of distributors, partners, and system integrators. For more information, contact Opto 22 headquarters at 800-3216786 or 951-695-3000, or visit our website at www.opto22.com. www.opto22.com www.opto22.com * Opto 22 * 43044 Business Park Drive * Temecula, CA 92590-3614 * Form 1335-110907 SALES 800-321-6786 * 951-695-3000 * FAX 951-695-3095 * sales@opto22.com * SUPPORT 800-835-6786 * 951-695-3080 * FAX 951-695-3017 * support@opto22.com (c) 2012 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.