ACM06 Series AC-DC Power Supplies
Output
Characteristic Minimum Typical Maximum Units Notes & Conditions
Output Voltage 5 12 V See Models and Ratings table
Minimum Load 0ANo minimum load required
Start Up Delay 4s
Start Up Rise Time 30 ms
Hold Up Time 10 ms Full load and 100 VAC
Total Regulation 5%See Models and Ratings table
Transient Response 4 % deviation For a 50% step load change at 0.15 A/µs
Ripple & Noise 150 mV pk-pk Measured with 20 MHz bandwidth and 10 µF electrolytic in
parallel with 0.1 µF ceramic capacitor
Short Circuit Protection Continuous, trip and restart (hiccup mode) with auto recovery
Temperature Coefficient 0.05 %/ ˚C
xxx Series
www.xppower.com
1
Models & Ratings
Notes
1. Model number is for body only. AC input plugs must be ordered separately, see
AC input plug section.
2. Other output voltages available, contact sales for details.
3. Total regulation includes initial set accuracy, line and load regulation.
4. Typical average value measured at 115 VAC.
5. For white case version add suffix ‘-W’ e.g. ACM06US12-W. MOQ applies, contact
sales for details.
6. For 5 V version with optional USB type A connector in case, add suffix -BB,
e.g ACM06US05-BB.
Dimensions:
ACM (body only):
2.89 x 1.21 x 1.67” (73.5 x 30.7 x 42.5 mm)
6 Watt
Output Power Output Voltage Output Current Total Regulation(3) Efficiency(4) Model Number(1,2,5)
6 W
5.0 V 1000 mA 5% 80.0% ACM06US05(6)
9.0 V 600 mA 5% 79.8% ACM06US09
12.0 V 500 mA 5% 82.0% ACM06US12
• Energy Efficiency Level VI
• European CoC Tier 2
• Medical and ITE Approvals
• Interchangeable Mains Connectors
• Optional White Versions
• Output Voltages from 5 V to 12 V
• Class II Construction
• 3 Years Warranty
Input
Characteristic Minimum Typical Maximum Units Notes & Conditions
Input Voltage 90 264 VAC
Input Frequency 47 63 Hz
Input Current 0.2 A 100 VAC
Inrush Current 70 A 240 VAC, cold start at 25 °C
Power Factor EN61000-3-2, class A
No Load Input Power 75 mW
Input Protection Internal fuse in line
The ACM06 series of wall plug adaptors comply with the latest energy efficiency level VI standards
with high active mode efficiency and extremely low no load power consumption. Available with a
standard jack plug connector as well as USB versions, these adaptors suit a wide variety of cost
sensitive industrial and medical applications while maintaining industry leading performance.