DATASHEET IEC Inlet Filters FN 9290 Ultra Compact and Versatile Filtered Power Entry Module Approvals Dual stage filter Ultra compact design Rated currents up to 10 A Dual fuse holder 2-pole rocker switch Good attenuation performance Faston or spring cage terminals Check the video of our IEC Inlet Filters FN 9280 and FN 9290 on Youtube! Performance indicators (CQC except HI-types; Patent US 20110227692/US 8766761; CN ZL201080069589.0) Choosing FN 9280/90 product line brings you the rapid availability of a standard filter associated with the necessary safety acceptances and a high attenuation performance. For higher attenuation performance the FN 9290 family with a dual stage filter and identical panel cut-out can be used. Standard IEC connector filters are a practical solution to pass EMI system approval in a short time. A wide selection of amperage ratings, mounting possibilities and also filters for medical applications are designed to offer you the best solution. Features and benefits Good conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior Technical specifications 1 to 10 A @ 40C max. Deep-drawn iron-sheet housing for best possible shielding against magnetic fields DC to 400 Hz Rear/front flange mounting or snap-in versions Standard: <500 uA at 250 VAC/50 Hz Medical: <5 uA at 250 VAC/50 Hz Dual and additional spare fuse holder Maximum continuous operating voltage Rated currents Operating frequency Leakage current 250 VAC, 50/60 Hz High potential test voltage P -> PE 2000 VAC for 2 sec (standard types) P -> PE 2500 VAC for 2 sec (B types) P -> N 760 VAC for 2 sec Design corresponding to UL 1283, CSA 22.2 No. 8 1986, EN 60939, EN 60950, EN 60601-1, UL 544, EN 60320 Flammability corresponding to Temperature range (operation and storage) Protection category Terminals Spring cage wire range UL 94 V-2 or better - 25C to +85C (25/85/21) IP 40 according to IEC 60529 (front side) 2-pole rocker switch Faston or spring cage terminals for more flexible assembly Medical version (B Type) according IEC/EN 60601-1 All versions according IEC/EN 62368-1 Typical applications IP 20 spring cage safe against finger touch Portable electrical and electronic equipment 0.2 -1.5 mm2/24 -16 AWG single or flexible wire Consumer goods MTBF @ 40C/230 V (Mil-HB-217F) Switch ratings > 1,000,000 hours EDP and office equipment Rocker switch USA (UL) and Canada (C-UL) Europe (ENEC) Mechanical life Electrical specifications 2-pole, dark not illuminated, Marking I - 0 Fuse holder 2 fuses (O5 x 20 mm) max. 250 V (certified to IEC 60127-6) Single-phase and switch-mode power supplies 10 A, 125 VAC; 10 A, 250 VAC; 1/3 HP 10 A (4 A), 250 VAC** 50,000 cycles Inrush current 82 A 6,000 on-off operations according to UL 1054 10,000 on-off operations according to ENEC * 10 A version is 8 A UL and CSA approved ** Value in () relates to the inductive current charge: cos = 0.65 Test and measurement equipment Medical electrical devices (MD) and In-VitroDiagnostics (IVD) equipment Audio/Video, information and communication technologies Typical electrical schematic 2 EMC/EMI Products Schaffner Group Datasheets 08 Mar 2019 Filter selection table Filter* Rated current Leakage current** Inductance Capacitance Resistance Output Weight connections @ 40C @ 250 VAC /50 Hz L1 L2 Cx Cy1 Cy2 R (@ 120 VAC /60 Hz) [A] [mA] [mH] [mH] [nF] [nF] [nF] [kOhm] FN 9290-1-.. 1 0.28 (0.16) 10.9 10.9 220 1.5 0.47 1000 -06 -100 147 FN 9290-2-.. 2 0.28 (0.16) 4.4 4.4 220 1.5 0.47 1000 -06 -100 148 FN 9290-4-.. 4 0.28 (0.16) 1.7 1.7 220 1.5 0.47 1000 -06 -100 148 FN 9290-6-.. 6 0.28 (0.16) 0.78 0.78 220 1.5 0.47 1000 -06 -100 153 FN 9290-10-.. 10 0.28 (0.16) 0.32 0.32 220 1.5 0.47 1000 -06 -100 154 FN 9290 B-1-.. 1 0.00 10.9 10.9 220 0 0 1000 -06 -100 147 FN 9290 B-2-.. 2 0.00 4.4 4.4 220 0 0 1000 -06 -100 148 FN 9290 B-4-.. 4 0.00 1.7 1.7 220 0 0 1000 -06 -100 148 FN 9290 B-6-.. 6 0.00 0.78 0.78 220 0 0 1000 -06 -100 153 FN 9290 B-10-.. 10 0.00 0.32 0.32 220 0 0 1000 -06 -100 154 FN 9299-1-.. 1 0.28 (0.16) 10.9 10.9 220 1.5 0.47 1000 -06 -100 147 FN 9299-2-.. 2 0.28 (0.16) 4.4 4.4 220 1.5 0.47 1000 -06 -100 148 FN 9299-4-.. 4 0.28 (0.16) 1.7 1.7 220 1.5 0.47 1000 -06 -100 148 FN 9299-6-.. 6 0.28 (0.16) 0.78 0.78 220 1.5 0.47 1000 -06 -100 153 FN 9299-10-.. 10 0.28 (0.16) 0.32 0.32 220 1.5 0.47 1000 -06 -100 154 FN 9299 B-1-.. 1 0.00 10.9 10.9 220 0 0 1000 -06 -100 147 FN 9299 B-2-.. 2 0.00 4.4 4.4 220 0 0 1000 -06 -100 148 FN 9299 B-4-.. 4 0.00 1.7 1.7 220 0 0 1000 -06 -100 148 FN 9299 B-6-.. 6 0.00 0.78 0.78 220 0 0 1000 -06 -100 153 FN 9299 B-10-.. 10 0.00 0.32 0.32 220 0 0 1000 -06 -100 154 * To compile a complete part number, please replace the -.. with the required output connection style (e.g. FN 9289-1-06, FN 9282-4-100) ** Maximum leakage current under normal conditions (according to IEC60939-3) Product selector: [g] 3 EMC/EMI Products Schaffner Group Datasheets 08 Mar 2019 All FN 9280/FN 9290 are equipped with a dual fuse holder with a spare fuse holder. Note: All FN 9280/FN 9280 B/FN 9289/FN 9289 B/FN 9290/FN 9290 B/FN 9299/FN 9299 B are stock types from our distribution partners. Order Examples: FN 9280 B-6-100: Medical version of single stage, dual fuse EMC/EMI filter, flange set for vertical/horizontal/front/rear mounting, 6 A, spring cage terminals, from stock available. FN 9298-6-06-30: Dual stage, dual fuse EMC/EMI filter, snap-in version, snappers for snap-in panel thickness range >2.5 to 3.5 mm, snapper on vertical side, 6 A, fast-on terminals, non-stock order type Typical filter attenuation FN 9290 Series | Typical filter attenuation | Per CISPR 17; A=50 /50 sym; B=50 /50 asym 1 A types 2 A types 4 - 6 A types 10 A types B A FN 9290 B Series | Typical filter attenuation | Per CISPR 17; A=50 /50 sym; B=50 /50 asym 1 A types 2 A types 4 - 6 A types 10 A types B A 4 EMC/EMI Products Schaffner Group Mechanical Data FN 9290-x-06/FN 9290 B-x-06 FN 9290-x-100/FN 9290 B-x-100 FN 9299-x-06/FN 9299 B-x-06 FN 9299-x-100/FN 9299 B-x-100 Datasheets 08 Mar 2019 5 EMC/EMI Products Schaffner Group Datasheets 08 Mar 2019 Assembly Instructions Terminal -100 clamping range, solid wire / flex wire 0,20 mm -1,5 mm, AWG24 -AWG16 operating force of slider recommended stripped length max. 40 N 8 mm Push the knob above the terminal to insert the wire. Removal of the combined switch / fuse holder unit An additional fuse mark on the switch indicates the fuses holders behind the switch. The red frame shows the outline of the removable unit. With a simple tool like a Swiss Army knife or a screwdriver No 1 or smaller the unit (1) can be removed from the filter. On the topside (2) behind the switch there are two fuse holders for each live connection. On the bottom side (3) is a clip to carry an additional spare fuse. Please visit www.schaffner.com to find more details on filter connectors. 6 EMC/EMI Products Schaffner Group Datasheets 08 Mar 2019 Accessories for IEC Inlet Filters and Power Entry Modules The accessories displayed are a selection of available accessories for IEC Inlet filters and IEC Power entry modules. As they are displayed in a general way there might be variants of the filters where the accessories are not available. For further information please ask your local Schaffner Sales Partner and visit our homepage https://www.schaffner.com/. Power Cor Cord d with LLock ocking ing Syst System em ffor or IInlet nlet FFilt ilters ers IL 13, IL 13 P P,, IL 19 Link to Datasheet: Datasheet IEC C13/ C19 locking cable The locking system has a tensile force of typical 200N. It is recommended to use it with flange mount filters. Lock Power Cords with IEC Inlets and Filters" Schaffner power cords with IEC lock guard against accidental disconnection of all electrical appliances with an IEC inlet. No exchange or modification of the IEC inlet or IEC inlet filter system is needed. Easy retrofit for all electronic equipments and devices. IEC C13 R Re ewir wireable eable Connec Connecttor for individual P Po ower Cor Cord d with Lock ocking ing Syst System em Link to Datasheet: Datasheet IEC C13 rewireable The locking system has a tensile force of typical 300N. It is recommended to use it with flange mount filters. For details refer to our Application Note "Using IEC Lock Power Cords with IEC Inlets and Filters" Schaffner power connector with IEC lock guard against accidental disconnection of all electrical appliances with an IEC inlet. No exchange or modification of the IEC inlet or IEC inlet filter system is needed. Easy retrofit for all electronic equipments and devices. 7 EMC/EMI Products Schaffner Group Datasheets 08 Mar 2019 Headquarters, global innovation and development Sales and application centers Switzerland Schaffner Group Nordstrasse 11 4542 Luterbach T +41 32 681 66 26 info@schaffner.com China Schaffner EMC Ltd. Shanghai T20-3 C, No 565 Chuangye Road, Pudong district 201201 Shanghai T +86 21 3813 9500 cschina@schaffner.com www.schaffner.com.cn Spain Schaffner EMC Espana Calle Calendula 93, Miniparc III, Edificio E El Soto de Moraleja, Alcobendas 28109 Madrid T +34 917 912 900 F +34 917 912 901 spainsales@schaffner.com Finland Schaffner Oy Sauvonrinne 19 H 08500 Lohja T +358 50 468 7284 finlandsales@schaffner.com Sweden Schaffner EMC AB Tegeluddsvagen 76, 2tr 115 28 Stockholm T +46 8 5050 2425 swedensales@schaffner.com www.schaffner.com France Schaffner EMC S.A.S. 16-20 Rue Louis Rameau 95875 Bezons T +33 1 34 34 30 60 F +33 1 39 47 02 28 francesales@schaffner.com Germany Schaffner Deutschland GmbH Schoemperlenstrasse 12B 76185 Karlsruhe T +49 721 56910 F +49 721 569110 germanysales@schaffner.com India Schaffner India Pvt. Ltd REGUS WORLD TRADE CENTRE WTC, 22nd Floor Unit No 2238, Brigade Gateway Campus, 26/1, Dr. Rajkumar Road Malleshwaram (W) 560055 Bangalore T +91 80 67935355 indiasales@schaffner.com To find your local partner within Schaffner`s global network: www.schaffner.com (c) 2018 Schaffner Group The content of this document has been carefully checked and understood. However, neither Schaffner nor its subsidiaries assume any liability whatsoever for any errors or inaccuracies of this document and the consequences thereof. Published specifications are subject to change without notice. Product suitability for any area of application must ultimately be determined by the customer. In all cases, products must never be operated outside their published specifications. Schaffner does not guarantee the availability of all published products. This disclaimer shall be governed by substantive Swiss law and resulting disputes shall be settled by the courts at the place of business of Schaffner Holding AG. Latest publications and a complete disclaimer can be downloaded from the Schaffner website. All trademarks recognized. Italy Schaffner EMC S.r.l. Via Ticino, 30 20900 Monza (MB) T +39 039 21 41 070 italysales@schaffner.com Japan Schaffner EMC K.K. 1-32-12, Kamiuma, Setagaya-ku 7F Mitsui-seimei Sangenjaya Bldg. 154-0011 Tokyo T +81 3 5712 3650 F +81 3 5712 3651 japansales@schaffner.com www.schaffner.jp Singapore Schaffner EMC Pte Ltd. #05-09, Kg Ubi Ind. Estate 408705 Singapore T +65 6377 3283 F +65 6377 3281 singaporesales@schaffner.com Switzerland Schaffner EMV AG Nordstrasse 11 4542 Luterbach T +41 32 681 66 26 switzerlandsales@schaffner.com Taiwan R.O.C. Schaffner EMV Ltd. 20 Floor-2, No 97, Section 1, XinTai 5th Road 22175 XiZhi District New Taipei City 22175 T +886 2 2697 5500 F +886 2 2697 5533 taiwansales@schaffner.com www.schaffner.com.tw Thailand Schaffner EMC Co. Ltd. Northern Region Industrial Estate 67 Moo 4 Tambon Ban Klang Amphur Muangg P.O. Box 14 51000 Lamphun T +66 53 58 11 04 F +66 53 58 10 19 thailandsales@schaffner.com United Kingdom Schaffner Ltd. 5 Ashville Way, Molly Millars Lane Wokingham RG41 2PL Berkshire T +44 118 9770070 F +44 118 9792969 uksales@schaffner.com USA Schaffner EMC Inc. 52 Mayfield Avenue Edison, New Jersey T +1 732 225 9533 F +1 732 225 4789 usasales@schaffner.com www.schaffnerusa.com Schaffner North America 6722 Thirlane Road 24019 Roanoke, Virginia T +1 276 228 7943 F +1 276 228 7953 Schaffner North America 823 Fairview Road 24382 Wytheville, Virginia T +1 276 228 7943 F +1 276 228 7258