www.white-rodgers.com 115
RELAYS and
TRANSRORMERS
13
56
2 4
1.500
MAX.
1.265
MAX.
1.265
.500
1.842 2.156 2.670
.150 DIA.
HEAVY-DUTY
ENCLOSED FAN RELAYS
90-360 THRU 90-486 WR/RBM TYPE 184
Heavy-Duty General Purpose Relay Operates in Any Position
SPECIFICATIONS
Temperature Range . . . . . . . . . . . . . . . . –40°F to 150°F
Mechanical Life (no load) . . . . . . . . . . . . 1,000,000 operations, 120 operations/min.
Electrical Life (rated load). . . . . . . . . . . . 100,000 operations, 6 operations/min.
Load test making inrush rating (0.4 to
0.5 P.F.); breaking 100% continuous rating
(0.65 to 0.8 P.F.)
Weight (approximate) . . . . . . . . . . . . . . . 2.3 oz.
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. le number E12139 or E22381
C.S.A. le number LR13360
Coils, Frequency. . . . . . . . . . . . . . . . . . . 50/60 Hz
Coils, Insulation . . . . . . . . . . . . . . . . . . . Class B
Coils, Termination . . . . . . . . . . . . . . . . . . 1/4 Quick Connect
Coils, Operate. . . . . . . . . . . . . . . . . . . . . 85% of nominal coil voltage;
110% maximum safe operate
Coils, Duty Cycle . . . . . . . . . . . . . . . . . . Continuous
FEATURES
Compact, totally enclosed design.
For heating and cooling applications and general switching.
Quiet, reliable and economical.
Coil Data
Model Number Coil Voltage AC Res DC Nom. Current Nominal Inrush
SPNO SPDT SPNO/SPNC (50/60 Hz) OHMS MA VA Sealed VA
90-360 90-370 90-380 24 77 125 3 4
90-362 90-372 90-382 120 2,000 25 3 4
90-364 90-374 90-384 240 6,050 12.5 3 4
90-466 90-476 90-486 277 10,300 10.8 3 4
SINGLE POLE NORMALLY OPEN, SINGLE POLE DOUBLE THROW (SPDT) ISOLATED CONTACTS (SPNO/SPNC)
Inductive Resistive
12 Amps. Continuous
60 Amps. Inrush 18 Amps.
@ 125 VAC Continuous
8 Amps. Continuous @ 277 VAC
48 Amps. Inrush
@ 250 VAC
CONTACT RATING
SPNO
SPDT
WIRING DIAGRAMS
SPNO/SPNC
Totally Enclosed Relay
Operates in Any Position
Isolated Coil and Mounting Bracket
C