1
POWER RELAY
ULTRA SMALL HIGH VOLTAGE DC RELAY
FTR-J2 Series
FEATURES
10A, 450VDC high-voltage switching (2 x 10A, 200VDC switching)
Contact voltage drop: typical 0.1V
Inrush current 150A (capacitive load)
Compact size (L x W X H= 24x23.5x27mm)
2 x 1 form A tween contacts and coil
Insulation distance: Clearance/creepage > 6mm
Dielectric strength: 4 ,000 VAC
Surge strength: 10,000 V (1.2 x 50µsec)
Plastic materials conform to UL94 ame class V-0
Flux proof, RTII
RoHS compliant (Please see page 9 for more information)
Part Numbers
[Example] FTR-J2 - A K 012 W
(a) (b) (c) (d) (e)
(a) Relay type FTR-J21 : FTR-J2 series
(b) Contact conguration A : 2 x 1 form A
(c) Coil power K : Standard sensitivity
(d) Coil rated voltage 012 : 5....110VDC
Coil rating table at page 4
(e) Contact material W : Silver alloy
Actual marking does not carry the type name: "FTR"
E.g.: Ordering code: "FTR-J2AK012W", actual marking: "J2AK012W"
2
FTR-J2 Series
Specications (1/2)
Item FTR-J2 Remarks / conditions
Contact
data
Conguration 1 form A x 2
Material Silver alloy
Resistance Max.100 at 1A, 6VDC between contact terminals
Note1
Contact rating 10A, 450VDC (resistive load) When 2 contacts connected in series
through a common load
10A, 200VDC (resistive load) When each NO contact is used inde-
pendently
Overload switching 10A, 500VDC (resistive load) 50 ops. When 2 contacts connected in series
through a common load
10A, 250VDC (resistive load) 50 ops. When each NO contact is used inde-
pendently
Max. carrying current 12A per contact 2 contacts connected in series through
a common load is counted as 1 contact
Note2
Inrush current Peak 150A per contact 2 contacts connected in series through
a common load is counted as 1 contact
Note2
Max. switching voltage 600VDC When 2 contacts connected in series
through a common load
300VDC When each NO contact is used inde-
pendently
Contact voltage drop (initial) Max. 0.1V per contact At 10A, between contact terminals Note1
Minimum switching load
(reference * )
100mA 5VDC per contact 2 contacts connected in series through
a common load is counted as 1 contact
Note2
Coil Rated power 530mW Standard single coil at 20°C (Please
refer to Coil Rating for 2 coils)
Operate voltage Maximum 70% of nominal voltage At 20°C
Release voltage Maximum 5% of nominal voltage At 20°C
Operating temperature range -40ºC ~ +85ºC No frost Note3
Timing
data
Operate Max. 15ms (without bounce) At nominal voltage, 20°C, with varistor
Release Max. 5ms (without bounce)
Life Mechanical Min. 2M operations per contact 2 contacts connected in series through
a common load is counted as 1 contact
Note2
Electrical Min. 10K operations per contact 2 contacts connected in series through
a common load is counted as 1 contact
Note2
Insula-
tion
Insulation resistance (initial) Min. 1000MΩ at 500VDC
Dielectric
strength
Open
contacts
1000VAC (50/60Hz), 1 minute Note2
Adjacent
contact
1000VAC (50/60Hz), 1 minute Note1
Coil contacts 4000VAC (50/60Hz), 1 minute Note1
Surge strength Coil to con-
tacts
10000V / 1.2 x 50µm standard wave Note2
3
FTR-J2 Series
Specications (2/2)
Other Vibration resis-
tance
Misoperation 10Hz ~ 55Hz ~ 10Hz single amplitude
0.75mm
Coil ON/OFF, 3 axes, total 6 cycles
Endurance 10Hz ~ 55Hz ~ 10Hz single amplitude
0.75mm
Coil OFF, 3 axes, total 6 hours
Shock resis-
tance
Misoperation Min. 200m/s² (11 ± 1ms) Coil ON/OFF, 3 axes,
total 36 operations
Endurance Min. 1,000m/s² (6 ± 1ms) Coil OFF, 3 axes,
total 18 operations
Dimensions / weight 23.5 x 24.0 x 27.0 mm / approx. 26g
Sealing Flux proof RTII
Values of electrical characteristics are under 15 to 35 degC, 25 to 75%RH, air pressure 86kPa to 106kPa (JIS standard condition) unless otherwise specied.
* Minimum switching loads mentioned above are reference values. Please perform the conrmation test with actual load before production since reference values
may vary according to switching frequencies, environmental conditions and expected reliability levels.
Note 1: The specication value is applied to each contact in case 2 coils are connected in series through a common load.
Note 2: The contacts connected in series are considered as an integrated contact in case 2 coils are connected in series through a common load.
Note 3: There are cases where the relay does not operate when it is used at high ambient temperature. Please refer to characteristic data and apply adequate coil
voltage.
!There would be a possibility that high voltage DC relay loses breaking current ability as one of failure modes.
Please provide fail safeness design on the circuit. To secure safety, the relay shall not be used in exceeding its specications including operation life, and
handle the relay as a periodic maintenance component.
!Relay contact terminals have polarity. Please connect higher potential side of the load to (+). Please refer to recommended circuit layout.
!Please always use a varistor to protect the coil from back electromotive force. Use of other protection element may shorten relay life excessively.
!Varistor shall be connected in parallel to the relay coil.
Please refer to recommended circuit layout.
Varistor voltage shall have 3 times as high as applied coil voltage.
!Care shall be taken on the heat generated on PC board when maximum carrying current exceeds 10A. Please perform the conrmation test with actual
conditions.
4
FTR-J2 Series
Coil Data
Standard single coil
Coil code Rated Coil Voltage
(VDC)
Coil Resistance +/-10%
(Ω)
Must Operate Voltage*
(VDC)
Must Release Voltage*
(VDC)
Rated Power (W)
(±10%)
005 5 47 3.5 0.25
Approx.
0.53
006 6 68 4.2 0.3
012 12 270 8.4 0.6
024 24 1,100 16.8 1.2
048 48 4,400 33.6 2.4
060 60 6,790 42.0 3
110 110 22,800 77.0 5.5
2 coils in series (Connect relay coil terminal No.2 to No.3) See note 2.
Coil code Rated Coil Voltage
(VDC)
Coil Resistance +/-10%
(Ω)
Must Operate Voltage*
(VDC)
Must Release Voltage*
(VDC)
Rated Power (W)
(±10%)
005 10 94 7.0 0.5
1.06
006 12 136 8.4 0.6
012 24 540 16.8 1.2
024 48 2,200 33.6 2.4
048 96 8,800 67.2 4.8
060 120 13,580 84 6
110 220 45,60 154 11
2 coils in parallel (Connect relay coil terminal No.1 to No.3 and No.2 to No.4)
Coil code Rated Coil Voltage
(VDC)
Coil Resistance +/-10%
(Ω)
Must Operate Voltage*
(VDC)
Must Release Voltage*
(VDC)
Rated Power (W)
(±10%)
005 5 23.5 3.5 0.25
1.06
006 6 34 4.2 0.3
012 12 135 8.4 0.6
024 24 550 16.8 1.2
048 48 2,200 33.6 2.4
060 60 3,395 42.0 3
110 110 11,400 77.0 5.5
Note 1: All values in the tables are valid for 20°C and zero contact current.
Note 2: Nominal voltage is different from indication of part number
Note 3: Please use at rated coil voltage. Please refer to characteristic data and set up adequate voltage in case of use at over voltage.
* Specied operate values are valid for pulse wave voltage.
Safety Standards
Type Compliance Contact rating
UL UL 508
File No. E63615
10A, 450VDC, resistive, 10,000 cycles
for series connection of each NO contact.
10A, 400VDC, resistive, 10,000 cycles
for series connection of each NO contact.
10A, 200VDC, resistive, 10,000 cycles for each NO contact.
VDE IEC/EN61810-1 10A, 400VDC, resistive, 10,000 cycles
for series connection of each NO contact.
10A, 200VDC, resistive, 10,000 cycles for each NO contact
5
FTR-J2 Series
Characteristic Data (Reference)
* Characteristic data is not a guaranteed value, but measured values of samples from production line.
60
50
40
30
20
10
0
0 2 4 6 8 10 12
450VDC
60
50
40
30
20
10
0
0 2 4 6 8 10 12
200VDC
00.2 1.2
0.8
0.60.4 1 1.6
1.4
70
60
50
40
30
20
10
0
10A
0 10 20 30 40 50 60 70 80 90 100
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
10A
Coil temperature rise
(contacts connected in series)
Life curve
(contacts connected in series in the same load)
Life curve
(Each contact is used independently)
0A
0A
Operating range
(contacts connected in series)
Temperature rise (°C)
Coil power (W)
Service live (x 10
operations)
Service live (x 10
operations)
Contact current load (A)
Contact current load (A)
Note: When each contact is used independently, above
graph shall be read; same voltage is applied on 2 coils,
coil power is sum of 2 coils, applied current 10A is 10A
apply on each contact set.
Note: When each contact is used independently, above
graph shall be read; same voltage is applied on 2 coils,
applied current 10A is 10A apply on each contact set.
Nominal voltage multiplying factor
Ambient temperature (°C)
Operate voltage (hot coil)
Operate voltage (cool coil)
resistive resistive
6
FTR-J2 Series
Dimensions
Dimensions
* Dimensions of the terminals do not include thickness of pre-solder.
Schematics
(BOTTOM VIEW)
PC Board Mounting Hole Layout
(BOTTOM VIEW)
( ): Reference value
Unit: mm
* Tolerance of PC board mounting hole layout : ±0.1 unless otherwise specied.
.
.
24+0.3 23+0.3
27+0.3
(1.8) 16.5
φ0.5
3.5 5
1
1
7.5
7.5
8- pre solder
0.35
3.3
0.4
Relay contact terminals have polarity.
Please connect higher potential side of the load to (+).
Please always use a varistor to protect the coil from back
electromotive force.
Use of other protection element may shorten relay life exces-
sively. Varistor must connect in parallel to the relay coil.
Please refer to Recommended Circuit.
4
37
2
1
6
8+
5+
7.5±0.1
7.5±0.1
7.5±0.1
(23.5)
(1.75)
4- φ1.3±0.1
4- φ0.9±0.1
3.5±0.1
3.5±0.1
16.5±0.1
16.5±0.1
(1.8)
(24)
5±0.1
5±0.1
7.5±0.1
7
FTR-J2 Series
Circuit
■ Recommended Circuit (2 contacts connected in series under the same common load)
■ Recommended Circuit (each contact is used independently)
BOTTOM VIEW
BOTTOM VIEW
1
2
3
4
5
6
7
8
V
1
2
3
4
5
6
7
8
V
1
2
3
4
5
6
7
8
V
1
2
3
4
5
6
7
8
VV
Load circuit and input circuit (coil sides) for 10A 450VDC
(2 coils connect in series)
Load circuit and input circuit (coil sides) for 10A, 200VDC
(dual circuit) 2 coils connect in series
Load circuit and input circuit (coil sides) for 10A, 200VDC
(dual circuit) Each coil is used independently
Load circuit and input circuit (coil sides) for 10A 450VDC
(2 coils connect in parallel)
Surge protection
device (Varistor)
Surge protection
device (Varistor)
Surge protection
device (Varistor)
Surge protection
device (Varistor)
Nominal
coil voltage
Nominal
coil voltage
Nominal
coil voltage
Nominal
coil voltage
Nominal
coil voltage
Connect on PC board
Connect on PC board
Connect on PC board
Current: 10A
Current: 10A
Current:10A
Current: 10A
Current: 10A Current: 10A
Current:10A
Current:10A
(+)
(+) (+)
(+)
(+)
(+)
(+)
(+)
Load
circuit
Load
circuit
Load
circuit
Load
circuit
Load
circuit
Load
circuit
Power
supply
450VDC
Power
supply
200VDC
Power
supply
200VDC
Power
supply
200VDC
Power
supply
200VDC
Power
supply
450VDC
Load circuit contact terminals has polarities (+) and (-). Coils do not have polarity.
Load circuit contact terminals has polarities (+) and (-). Coils do not have polarity.
Note 1: In case 2 coils are connected in series, connect coil terminal #2 to #3 on PCB circuit. In case 2 coils are connected in parallel,
connect coil terminal #1 to #3 and connect coil terminal #2 to #4 on PCB. Regarding terminal number, refer to schematics data.
Note 2: Please use varistor as surge protection device. If varistor will not be used, the electrical life need to be derated.
Note 3: Varistor surge protection device should be connect parallel to coil(s). Suitable voltage of varistor is 3 times the coil voltage.
Note 4: For max. contact life and correct functioning of the relay, positive polarity of load should be connected to pin 8 and pin 5.
If not, damage to the relay can occur.
!Warning: At current loads at max. switching capacity 10A (200VDC) correct polarity is vital for the correct and safe functioning of the relay
8
FTR-J2 Series
WARNING
We highly recommend to use the circuit layouts on this datasheet to switch 10A 450VDC or 10A 200VDC.
Polarity of the terminals shall be kept as specied, otherwise re or electric shock may occur. There would be a
possibility that high voltage DC relay loses breaking current ability as one of failure modes. Please provide fail
safeness design on the circuit not to result in any injury or deaths or damages. To secure safety, the relay shall
not be used in exceeding its specications including operation life, and handle the relay as a periodic mainte-
nance component.
Caution
!Each coil shall be synchronized completely in case 2 coils are used separately at 10A 450VDC switching. In-
complete synchronization may shorten relay life excessively.
!Magnetic eld is generated on the top surface of relay. Please consider its inuence to other components.
When 2 or more relays are mounted quite closely, please conrm operation before actual use.
!All values mentioned in this datasheet are provided under ideal conditions. Please perform the conrmation
test before actual use.
!Reow soldering is prohibited
!Do not use FTR-J2 relays for automotive applications.
!Do not use relays in the atmosphere with sulde gas, chloride gas or nitric oxide. Contact resistance may
increase.
!Do not use silicon or silicon-containing product or materials near relays. It may cause contact failure.
!
9
FTR-J2 Series
GENERAL INFORMATION
1. ROHS Compliance
All relays produced by Fujitsu Components are compliant with RoHS directive 2011/65/EU including amend-
ments.
Use of Cadmium in electrical contacts is exempted as per Annex III of the RoHS directive 2011/65/EU.
Please consider expiry date of exemption. Relays with Cadmium containing contacts are not to be used for
new designs.
All relays are lead-free. Please refer to Lead-Free Status Info for older date codes at:
http://www.fujitsu.com/downloads/MICRO/fcai/relays/lead-free-letter.pdf
Characteristic data is not guaranteed values, but measured values of samples from production line.
2. Recommended lead free solder condition
Lead free solder plating on relay terminals is Sn-3.0Ag-0.5Cu, unless otherwise specied. This material has
been veried to be compatible with PbSn assembly process.
Recommended solder for assembly: Sn-3.0Ag-0.5Cu.
3. Moisture Sensitivity
Moisture Sensitivity Level standard is not applicable to electromechanical relays, unless otherwise indicat-
ed.
4. Tin Whiskers
Dipped SnAgCu solder is known as presenting a low risk to tin whisker development. No considerable
length whisker was found by our in house test.
We highly recommend that you conrm your actual solder conditions
Flow Solder Condition:
Pre-Heating: maximum 120˚C
within 90 sec.
Soldering: dip within 5 sec. at
255˚C ± 5˚C solder bath
Relay must be cooled by air immediately
after soldering
Solder by Soldering Iron:
Soldering Iron: 30-60W
Temperature: maximum 350-360˚C
Duration: maximum 3 sec.
10
FTR-J2 Series
Fujitsu Components International Headquarter Ofces
©2018 Fujitsu Components Europe B.V. All rights reserved. All trademarks or registered trademarks are the property of their respective owners.
The contents, data and information in this datasheet are provided by Fujitsu Component Ltd. as a service only to its user and only for general
information purposes.
The use of the contents, data and information provided in this datasheet is at the users’ own risk.
Fujitsu has assembled this datasheet with care and will endeavor to keep the contents, data and information correct, accurate, comprehensive,
complete and up to date.
Fujitsu Components Europe B.V. and afliated companies do however not accept any responsibility or liability on their behalf, nor on behalf of its
employees, for any loss or damage, direct, indirect or consequential, with respect to this datasheet, its contents, data, and information and related
graphics and the correctness, reliability, accuracy, comprehensiveness, usefulness, availability and completeness thereof.
Nor do Fujitsu Components Europe B.V. and afliated companies accept on their behalf, nor on behalf of its employees, any responsibility or liability
for any representation or warrant of any kind, express or implied, including warranties of any kind for merchantability or tness for particular use,
with respect to these datasheets, its contents, data, information and related graphics and the correctness, reliability, accuracy, comprehensiveness,
usefulness, availability and completeness thereof. Rev. March 16, 2018
Japan
FUJITSU COMPONENT LIMITED
Shinagawa Seaside Park Tower 19F,
12-4, Higashi-shinagawa 4-chome, Shinagawa-ku,
Tokyo,140-0002, Japan
Tel: (81-3) 3450-1682
Fax: (81-3) 3474-2385
Email: fcl-contact@cs.jp.fujitsu.com
Web: www.fujitsu.com/jp/fcl/
North and South America
FUJITSU COMPONENTS AMERICA, INC
2290 North First Street, Suite 212
San Jose, CA 95131, USA
Tel: (1-408) 745-4900
Fax: (1-408) 745-4970
Email: components@us.fujitsu.com
Web: us.fujitsu.com/components
Europe
FUJITSU COMPONENTS EUROPE B.V.
Diamantlaan 25
2132 WV Hoofddorp
Netherlands
Tel: (31-23) 5560910
Fax: (31-23) 5560950
Email: info@fceu.fujitsu.com
Web: www.fujitsu.com/uk/components
Asia Pacic
FUJITSU COMPONENTS ASIA, LTD.
102E Pasir Panjang Road
#01-01 Citilink Warehouse Complex
Singapore 118529
Tel: (65) 6375-8560
Fax: (65) 6273-3021
Email: fcal@sg.fujitsu.com
Web: www.fujitsu.com/sg/products/devices/components
China
FUJITSU ELECTRONIC COMPONENTS (SHANGHAI) CO., LTD.
Unit 4306, InterContinental Center
100 Yu Tong Road, Shanghai 200070,
China
Tel: (86-21) 3253 0998
Fax: (86-21) 3253 0997
Email: fcal@sg.fujitsu.com
Web: www.fujitsu.com/sg/products/devices/components
Hong Kong
FUJITSU COMPONENTS HONG KONG CO., LTD
Unit 506, Inter-Continental Plaza
No.94 Granville Road, Tsim Sha Tsui, Kowloon,
Hong Kong
Tel: (852) 2881-8495
Tex: (852) 2894-9512
Email: fcal@sg.fujitsu.com
Web: www.fujitsu.com/sg/products/devices/components/
Korea
FUJITSU COMPONENTS KOREA LIMITED
Alpha Tower #403, 645 Sampyeong-dong,
Bundang-gu, Seongnam-si, Gyeonggi-do,
13524 Korea
Tel: (82) 31-708-7108
Fax: (82) 31-709-7108
Email: fcal@sg.fujitsu.com
www.fujitsu.com/sg/products/devices/components/