SPECIFICATION CONTROL DRAWING TITLE 82A0811 Date WIRE, RADIATION-CROSSLINKED, MODIFIED FLEXIBLE ETFE-INSULATED, NORMAL WEIGHT, GENERAL PURPOSE, 600 VOLT Revision 11-5-13 F This specification sheet forms a part of the latest issue of Raychem Specification 80. JACKET - RADIATION-CROSSLINKED, MODIFIED FLEXIBLE ETFE CONDUCTOR - TIN-COATED COPPER PRIMARY INSULATION - RADIATION-CROSSLINKED, MODIFIED FLEXIBLE ETFE COLOR - LIGHT GREEN TABLE I. CONSTRUCTION DETAILS WIRE SIZE (AWG) PART NUMBER 1/ CONDUCTOR STRANDING (number x AWG) DIAMETER OF STRANDED CONDUCTOR (inch) MINIMUM MAXIMUM FINISHED WIRE MAXIMUM RESISTANCE AT 20C (ohms/1000 ft.) DIAMETER (inch) MAXIMUM WEIGHT (lbs/1000 ft.) 82A0811-24-* 24 105 x 44 .023 .027 28.2 .044 .003 2.5 82A0811-22-* 22 154 x 44 .029 .033 19.2 .054 .003 3.7 82A0811-20-* 20 154 x 42 .037 .043 11.7 .064 .004 5.2 82A0811-18-* 18 259 x 42 .047 .053 7.14 .076 .004 8.0 82A0811-16-* 16 259 x 40 .061 .067 4.53 .092 .005 11.9 82A0811-14-* 14 665 x 42 .078 .086 2.96 .116 .005 19.3 82A0811-12-* 12 665 x 40 .096 .106 1.89 .137 .006 27.9 1.12 82A0811-10-* 10 665 x 38 .126 .140 .187 .008 50.0 82A0811-8-* 8 665 x 36 .157 .173 .714 .230 .008 77.3 82A0811-6-* 6 1045 x 36 .192 .208 .490 .277 .010 118. 82A0811-4-* 4 1665 x 36 .265 .285 .326 .359 .010 189. 82A0811-2-* 2 1665 x 34 .325 .345 .204 .433 .016 282. 82A0811-1-* 1 2109 x 34 .370 .400 .163 .488 .016 348. 82A0811-0-* 0 2660 x 34 .435 .465 .133 .558 .016 442. 82A0811-00-* 00 3325 x 34 .485 .515 .102 .612 .016 544. 82A0811-000-* 000 4123 x 34 .540 .575 .087 .678 .016 668. 82A0811-0000-* 0000 5320 x 34 .615 .655 .066 .771 .022 863. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Page 1 of 2 DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL. THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Raychem Wire & Cable 501 Oakside Avenue Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297 (c) 2013 Tyco Electronics Corporation. All rights reserved. SPECIFICATION CONTROL DRAWING 82A0811 Page Revision 2 of 2 F TABLE II. PERFORMANCE DETAILS BEND TESTING PART NUMBER 1/ MANDREL DIAMETER (inch) ( 3%) WEIGHT (lbs) ( 3%) CROSSLINKING PROOF TEST CROSSLINKING PROOF TEST 82A0811-24-* .500 82A0811-22-* .500 1.00 82A0811-20-* .500 1.50 .750 2.00 82A0811-18-* .750 82A0811-16-* 1.00 2.00 82A0811-14-* 1.00 3.00 82A0811-12-* 1.50 3.00 82A0811-10-* 2.00 3.00 82A0811-8-* 3.00 4.00 82A0811-6-* 4.00 4.00 82A0811-4-* 5.00 4.00 82A0811-2-* 6.00 6.00 82A0811-1-* 8.00 6.00 82A0811-0-* 8.00 6.00 82A0811-00-* 10.0 8.00 82A0811-000-* 10.0 8.00 82A0811-0000-* 10.0 8.00 WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level CONCENTRICITY: 70% (minimum) CROSSLINKING PROOF TEST: 300 3C for 7 hours IDENTIFICATION AND COLOR STRIPING DURABILITY: 125 cycles (250 strokes) (minimum), 500 g weight INSULATION ELONGATION AND TENSILE STRENGTH: AWG 24-10: Elongation, 75% (minimum) Tensile Strength, 3500 lbf/in (minimum) AWG 8-0000: Elongation, 125% (minimum) Tensile Strength, 3000 lbf/in (minimum) INSULATION FLAWS: Primary Insulation, Spark Test, 1.5 kV (rms) at 3 kHz Impulse Dielectric Test, 6.0 kV (peak) Finished Wire, Spark Test, 3.0 kV (rms) at 3 kHz Impulse Dielectric Test, 8.0 kV (peak) INSULATION THICKNESS: AWG 24-18: .004 in. (minimum) for primary insulation .004 in. (minimum) for outer jacket AWG 16-10: .005 in. (minimum) for primary insulation .005 in. (minimum) for outer jacket AWG 8-4: .008 in. (minimum) for primary insulation .012 in. (minimum) for outer jacket AWG 2-0000: .010 in. (minimum) for primary insulation .015 in. (minimum) for outer jacket JACKET COLOR: White preferred SECANT MODULUS (Test per ASTM D 882): AWG 24-10: 5.0 x 104 lbf/in2 (maximum) AWG 8-0000: 4.0 x 104 lbf/in2 (maximum) 2% strain, 2 inch jaw separation, 0.2 inch/minute SHRINKAGE: 150 3C for 6 hours, AWG 24-10: 0.13 in. (maximum) in 12 inches AWG 8-0000: 0.25 in. (maximum) in 12 inches VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz 1/ PART NUMBER: The "*" in the part numbers on pages 1 and 2 shall be replaced by a color code designator. Example: AWG 12, white: 82A0811-12-9 AWG 12, white with a black stripe: 82A0811-12-90 1/ See footer section on page 1 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TE Connectivity: 82A0811-4-9-F874