Cell Type HR-AAUC Specifications Type : Nickel-Metal Hydride Battery Size : AA Typical 1200mAh Minimum 1100mAh Capacity 1) 14.2 mm Nominal Voltage 1.2V Charging Current x Time 50.0 mm 1200 mA x about 1.1h Fast Charge 2) Charge Fast Charge 2) Condition 0C - 40C Discharge Condition 0C - 50C Less than 30days -20C - 50C Storage Less than Condition 90days -20C - 40C Less than 1year -20C - 30C Ambient Temp. Internal Impedance 3) (after discharge to E.V.=1.0V) Approx. 20m(at 1000Hz) Weight 4) Approx. 22 g Size 4) :(Diameter) x (Height) Dimensions (with tube) D 14.2 mm H 50.0 mm 14.2(D) x 50.0(H) mm 1)Single cell capacity under the following condition. Charge : 120mAx16h, Discharge : 240mA(E.V.=1.0V) at 20C 2)Use recommended charging system. 3)After a few charge and discharge cycles under the above 1) condition. 4)With tube. Typical Characteristics Charge Discharge 1.8 1.6 0C Charge : 1200mA (-DV=10mV) Rest : 1h Discharge : 240mA, 1200mA, 2400mA (E.V.=1.0V) Ambient Temp. : 25C 1.5 25C 1.6 Cell Voltage (V) Cell Voltage (V) 1.7 40 1.5 1.4 1.3 1.2 Charge : 1200mA (-DV=10mV) Ambient Temp. : 0C,25C,40C 1.1 10 20 30 40 50 60 Charge Time (min) 240mA 1200mA 1.3 1.2 1.1 2400mA 1.0 1.0 0 1.4 70 80 0.9 0 200 400 600 800 1000 1200 Discharge Capacity (mAh) 2013/7