M5200 Industrial Pressure Transducer
M5200 www.meas-spec.com April 2014
1/6
CE Compliant
Wide Temperature Range
Compact
Variety of Pressure Ports and Electrical
Configurations
Optional Stainless Steel Snubber
Weatherproof
Gage, Sealed, Compound Gage
DESCRIPTION
The M5200 pressure transducers from the Microfused™ line of MEAS, with their modular design, offer
maximum flexibility for different configurations. This latest series sets a new price performance standard for
demanding commercial and heavy industrial applications. This series is suitable for measurement of liquid or gas
pressure, even for difficult media such as contaminated water, steam, and mildly corrosive fluids.
The pressure port material is machined from a solid piece of 17-4 PH stainless steel. Its durability is excellent
and there are no o-rings, welds or organics exposed to the pressure media. The M5200 is weatherproof and exceeds
the latest heavy industrial CE requirements including surge protection. The circuit is protected from reverse wiring at
input and short circuit at output.
This product is geared to the OEM customer for low to high volumes. MEAS stands ready to provide a
custom design of the M5200 where the volume and application warrants. Additional configurations not listed are either
available or possible. Please inquire for further information.
FEATURES APPLICATIONS
Heavy Industrial CE Approval
Industrial Process Control and Monitoring
10 V/m EMI Protection
Advanced HVAC Systems
Reverse Polarity Protection on Input
Refrigeration Systems
Short Circuit Protection on Output
Automotive Test Stands
±0.25% Accuracy
Off-Road Vehicles
±1.0% Total Error Band
Pumps and Compressors
Compact Outline
Hydraulic/Pneumatic Systems
-40°C to +125°C Operating Temperature
Agriculture Equipment
Weatherproof
Energy Generation and Management
STANDARD RANGES
Range (psi)
Gage
Sealed
Compound
Range (Bar)
Sealed
Compound
0 to 50
0 to 3.5
0 to 100
0 to 007
0 to 200
0 to 014
0 to 300
0 to 020
0 to 500
0 to 035
0 to 01k
0 to 070
0 to 03k
0 to 200
0 to 05k
0 to 350
0 to 07k
0 to 500
0 to 10k
0 to 700
0 to 15k
0 to 01k
Intermediate ranges available upon request.
M5200 Industrial Pressure Transducer
M5200 www.meas-spec.com April 2014
2/6
PERFORMANCE SPECIFICATIONS
Ambient Temperature: 25°C (unless otherwise specified)
PARAMETERS
MIN
TYP
MAX
UNITS
NOTES
Accuracy
(combined non linearity, hysteresis, and repeatability)
-0.25
0.25
%F.S.
BFSL
Isolation, Body to any Lead
100
@500VDC
Dielectric Strength
2
mA
@500VAC, 1min
Pressure Cycles
1.00E+6
0~FS Cycles
Proof Pressure
2X
Rated
Burst Pressure
5X
20k psi
Rated
Long Term Stability (1 year)
-0.25
0.25
%F.S.
Total Error Band
-1.0
1.0
%F.S.
Over compensated
temperature range
Compensated Temperature
-20
+85
°C
Operating Temperature
-40
+125
°C
Except cable 105°C max
Storage Temperature
-40
+125
°C
Load Resistance (RL)
RL > 100k
Ω
Voltage Output
Load Resistance (RL)
< (Supply Voltage -9V) / 0.02A
Ω
Current Output
Current Consumption
5
mA
Voltage Output
Rise Time (10% to 90%)
<2ms (Voltage Output); <3ms (Current Output); Without Snubber
Wetted Material
17-4PH Port, 316 Stainless Steel Snubber
Gage Pressure Reference Vent
Under 1k psi, customer to ensure venting through mating connector
Bandwidth
DC to 1KHz (Typical)
Shock
50g, 11msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A
Vibration
±20g, MIL-STD-810C, Procedure 514.2, Fig 514.2-2, Curve L
For custom configurations, consult factory.
Notes
All configurations are built with supply voltage reverse and output short-circuit protections.
CE Compliance
EN 55022 Emissions Class A & B
IEC 61000-4-2 Electrostatic Discharge Immunity (8kV contact/15kV air)
IEC 61000-4-3 Radiated, Radio-Frequency Electromagnetic Field Immunity (10V/m, 80M-1GHz)
IEC 61000-4-4 Electrical Fast Transient Immunity (1kV)
IEC 61000-4-5 Surge Immunity (V+ to V-: ±2KV/42Ω; L to Case: ±1KV/12Ω; V- to V0: ±1KV/4)
IEC 61000-4-6 Immunity to Conducted Disturbances Induced by Radio Frequency
Fields (150K~80MHz, 10V level for voltage output models, 3V level for current output model)
IEC 61000-4-9 Pulse Magnetic Field Immunity (100A/m peak)
For all CE compliance tests, max allowed output deviation ±1.5 %F.S.
M5200 Industrial Pressure Transducer
M5200 www.meas-spec.com April 2014
3/6
DIMENSIONS [mm]
Note: For Sumitomo and 1/2 NPT Conduit, contact factory for additional
information.
CODE
CONNECTION TYPE
DIM A
1
CABLE 2 FT
2.19 [55.6]
E
CABLE 3 FT
2.19 [55.6]
2
CABLE 4 FT
2.19 [55.6]
3
CABLE 10 FT
2.19 [55.6]
4
PACKARD CONNECTOR A
2.25 [57.2]
5
BAYONET CONNECTOR
2.11 [53.6]
6
FORM C
1.95 [49.5]
7
FORM A
2.10 [53.3]
9
PACKARD CONNECTOR B
2.25 [57.2]
D
M12 CONNECTOR
1.95 [49.5]
M
CABLE 1 M
2.19 [55.6]
N
CABLE 2 M
2.19 [55.6]
P
CABLE 5 M
2.19 [55.6]
R
CABLE 10 M
2.19 [55.6]
A
AMP CONNECTOR
2.10 [53.3]
S
SUMITOMO CONNECTOR
1.95 [49.5]
C
1/2" NPT CONDUIT
2.10 [53.3]
PRESSURE PORT TYPE
CODE
PORT
DIM B
DIM C REF.
2
1/4-19 BSPP
0.47
0.366
[11.94]
[9.3]
3
G3/8 JIS B2351
0.54
0.366
[13.72]
[9.3]
4
7/16-20UNF MALE SAE J514
STRAIGHT THREAD
0.45
0.366
[11.43]
[9.3]
5
1/4-18 NPT
0.60
0.366
[15.24]
[9.3]
6
1/8-27 NPT
0.39
0.366
[9.91]
[9.3]
B
G1/4 JIS B2351
0.47
0.366
[11.94]
[9.3]
E
1/4-19 BSPT
0.50
0.366
[12.7]
[9.3]
F
1/4-19 BSPP FEMALE
0.70
0.366
[17.78]
[9.3]
P
7/16-20UNF FEMALE SAE
J514 STRAIGHT THREAD
WITH INTEGRAL VALVE
DEPRESSOR
0.43
0.506
[10.92]
[12.85]
Q
M10 x 1.0 mm ISO 6149-2
0.42
0.366
[10.67]
[9.3]
S
M12 x 1.5 mm ISO 6149-2
0.53
0.366
[13.46]
[9.3]
U
G/14 DIN 3852 FORM E
GASKET DIN3869-14 NBR
0.47
0.445
[11.94]
[11.3]
W
M20 x 1.5 mm ISO 6149-2
0.70
0.366
[17.78]
[9.3]
G
M14 x 1.5 mm ISO 6149-2
0.40
0.366
[10.16]
[9.3]
1
4
3
2
2
1
3
2
1
3
21 3
2
1 3
M5200 Industrial Pressure Transducer
M5200 www.meas-spec.com April 2014
4/6
WIRING
CONNECTION +SUPPLY -SUPPLY P REF VENT
Bayonet A B F
Packard, A A B
Hole Through
Connector
Packard, B B A
Hole Through
Connector
Cable RED BLK In Cable
1/2NPT CONDUIT RED BLK In Cable
M12 1 3
Hole Through
Connector
AMP/TE 1 2
Hole Through
Connector
FORM C 1 2
Threads Through
Connector
FORM A 1 2
Threads Through
Connector
Sumitomo 1 2
Hole Through
Connector
CONNECTION +SUPPLY +OUTPUT COMMON NC. PINS P REF VENT
Bayonet A B C D,E F
Packard, A A C B
Hole Through
Connector
Packard, B B C A
Hole Through
Connector
Cable RED WHT BLK In Cable
1/2NPT CONDUIT RED WHT BLK In Cable
M12 1 2 3 4
Hole Through
Connector
AMP/TE 1 3 2
Hole Through
Connector
FORM C 1 2 3 4
Threads Through
Connector
FORM A 1 3 2 4
Threads Through
Connector
Sumitomo 1 3 2
Hole Through
Connector
Current Output Wiring
Voltage Output Wiring
NC. PINS
C,D,E
C
C
2,4
3
3,4
3,4
3
Notes:
1. NC pins are reserved for factory use only. Customers should not use these connections.
2. For cable connection, the drain wire is internally terminated to pressure port.
M5200 Industrial Pressure Transducer
M5200 www.meas-spec.com April 2014
5/6
CONNECTION TYPES
Note: Transmitter of gage pressure type requires vent to atmosphere on the pressure reference side. This is accomplished via cable from
the transmitter (the end of the cable should be terminated to clean and dry area) or through the customer mating connector/cable assembly
which has internal vent path.
WEATHERPROOF
Note: Weatherproof ratings are met when the mating connectors are installed properly and the cable termination is to dry and clean area.
OUTPUTS
CONNECTION DESCRIPTION
MATING HOUSING
P/N MATING TERMINAL
P/N RUBBER SEAL
P/N
Bayonet BAYONET PTIH-10-6P OR EQUIV PT06A-10-6S MIL-C-26482 - -
Packard 3-PIN METRI-PACK 150 12078090 12103881, QTY 3 -
Cable &
1/2NPT
Conduit
4-WIRE,22 AWG, SHIELDED,
PVC JACKET, 105 DEGC
- - -
M12
BINDER SERIES 713,
09 0439 387 04 OR EQUIV
4-POS FEMALE CONNECTOR - -
AMP/TE
AMP / TE 3-PIN ECONOSEAL
J SERIES
174357-2 & 174358-7
171630-1 (AWG 20~24)
171662-1 (AWG 16~20)
QTY 3
172746-1 (AWG 20~24)
172888-2 (AWG 16~20)
QTY 3
FORM C
INDUSTRIAL STANDARD 9.4MM
FORM C
HIRSCHMANN 933 024-100,OR,
ATAM KD046000B7 (SEAL INCL.)
- HIRSCHMANN 730 185-002
FORM A DIN EN 175 301-803-A 18MM
HIRSCHMANN 931 969-100,OR,
ATAM KA245000B4 (SEAL INCL.)
- HIRSCHMANN 730 801-002
Sumitomo SUMITOMO 3-PIN HV040
6189-6907
8100-3067 (AWG 20~22)
8100-3068 (AWG 16~18)
QTY 3
7165-1075 (INS. DIA 1.1~1.6MM)
7176-0621 (INS. DIA 1.6~1.9MM)
7165-0622 (INS. DIA 1.8~2.2MM)
QTY 3
CONNECTION TYPES
CONNECTION IP CODE
Bayonet IP67
Packard IP66
Cable IP67
1/2NPT CONDUIT IP67
M12 IP67
AMP/TE NOT RATED
FORM C IP65
FORM A IP65
Sumitomo IP67
WEATHER-PROOF RATING
CODE
OUTPUT SIGNAL SUPPLY VOLTAGE
3
0.5 - 4.5V
RATIOMETRIC
5 ± 0.25V
PROTECTED to 30V
4
1 - 5V 8 - 30V
5
4 - 20mA 9 - 30V
6
0 - 5V 8 - 30V
7
0 - 10V 12 - 30V
8
1 - 6V 8 - 30V
9
0.5 - 4.5V 5 - 30V
M5200 Industrial Pressure Transducer
M5200 www.meas-spec.com April 2014
6/6
ORDERING INFORMATION
M52
3
1
-
0
0
00
0
5
-
100P
G
Model
Output
Signal
Connection Type
-
Port
Material
Snubber
00
Label
Pressure
Port
-
Pressure
Range
Pressure
Type
M52
3 = 0.5 4.5V
Ratiometric
4 = 1 5V
5 = 4 20mA
6 = 0 5V
7 = 0 10V
8 = 1 6V
9 = 0.5 4.5V
1 = Cable 2 ft
E = Cable 3 ft
2 = Cable 4 ft
3 = Cable 10 ft
4 = Packard Connector A
5 = Bayonet Connector
6 = Form C
7 = Form A
9 = Packard Connector B
D = M12 Connector
M = Cable 1 m
N = Cable 2 m
P = Cable 5 m
R = Cable 10 m
A = Amp Connector
S = Sumitomo Connector
C = 1/2“ NPT Conduit
-
0 = 17-4PH
0 = No
Snubber
1 = Oxygen
Clean B40.1
Level IV
2 = With
Snubber
00
0 = Adhesive
Label
1 = Laser
Marking
2 = 1/4-19 BSPP
3 = G3/8 JIS
B2351
4 = 7/16-20UNF
Male SAE J514
Straight Thread
5 = 1/4-18 NPT
6 = 1/8-27NPT
B = G1/4 JIS
B2351
E = 1/4-19 BSPT
F = 1/4-19 BSPP
Female
P = 7/16-20UNF
Female SAE J514
with Integral Valve
Depressor
Q = M10 x 1.0 mm
ISO 6149-2
S = M12 x 1.5 mm
ISO 6149-2
U = G1/4 DIN
3852 Form E
Gasket DIN3869-
14 NBR
W = M20 x 1.5
mm ISO 6149-2
G = M14 x 1.5 mm
ISO 6149-2
-
050P
100P
200P
300P
500P
01KP
03KP
05KP
07KP
10KP
15KP
3.5B
007B
010B
020B
035B
070B
200B
350B
500B
700B
01KB
G = Gage
S = Sealed
(≥1k psi)
C = Compound
Gage
Note: For Sumitomo and 1/2 NPT Conduit, contact factory for additional information.
NORTH AMERICA
EUROPE
ASIA
Measurement Specialties
45738 Northport Loop West
Fremont, CA 94538
Tel: 1-800-767-1888
Fax: 1-510-498-1578
Sales: pfg.cs.amer@meas-spec.com
Measurement Specialties
(Europe), Ltd.
26 Rue des Dames
78340 Les Clayes-sous-Bois, France
Tel: +33 (0) 130 79 33 00
Fax: +33 (0) 134 81 03 59
Sales: pfg.cs.emea@meas-spec.com
Measurement Specialties
(China), Ltd.
No. 26 Langshan Road
Shenzhen High-Tech Park (North)
Nanshan District, Shenzhen 518057
China
Tel: +86 755 3330 5088
Fax: +86 755 3330 5099
Sales: pfg.cs.asia@meas-spec.com
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for
inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the
manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement
Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does
Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims
any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different
applications. All operating parameters must be validated for each customer application by customer’s technical experts. Measurement
Specialties, Inc. does not convey any license under its patent rights nor the rights of others.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TE Connectivity:
M5231-000005-500PG M5231-000005-100PG M5251-000005-01KPG M5251-000005-250PG M5241-000005-
250PG