UP030( )A-( )( )(I)(H) SERIES 30 Watt AC/DC Switching Modules Small Size Universal Input 90 to 264 VAC Conductive EMI Meets FCC/CISPR 22 Class B Designed to Meets UL,CSA,TUV Safety Standards SPECIFICATIONS All specifications are typical at nominal line, full load and 25C unless otherwise noted. INPUT SPECIFICATIONS Input Voltage Range .................................. 90-264VAC Input Frequency ........................................... 47-63 Hz Inrush Current .............................. 30A max.(Cold Start) Line Regulation1 ................................................ 1% GENERAL SPECIFICATIONS Hold-up Time .............................................. 16mS typ. Short Circuit Protection ............................... Continuous Overvoltage Protection.......................5VDC Output Only Hi-pot Isolation: Input/ Output..........................4242 VDC ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range .................... 0C to 50C Derating 40C to 50C...................................... 2%/C Temperature Coefficient ........................ 0.02%/C Storage Temperature Range .................. -40C to +85C Humidity, Non-Condensing ........................ 0 to 95% RH Cooling ........................................ Free- Air Convection EMI Filter(on Board): Conducted ....................... Meets FCC/CISPR 22 Class B Specification NOTE 1. Measured from 90 to 264 VAC. OUTPUT SPECIFICATIONS Model Number UP0301A-01I UP0301A-02I UP0301A-03I UP0302A-01I UP0302A-02I UP0302A-03I UP0301A-01H UP0301A-02H UP0301A-03H UP0302A-01H UP0302A-02H UP0302A-03H Output Voltage1 (Volts) 5 12 15 5 12 15 5 12 15 5 12 15 Output Current (mA) Ripple2P-P (mV) Efficiency (%) 5000 2500 2000 2500 1250 1000 5000 2500 2000 2500 1250 1000 50 120 150 50 120 150 50 120 150 50 120 150 69 75 75 69 75 75 69 75 75 69 75 75 Load Regulation3 Load Change 25-100% 1% 1% 1% 5% 3% 3% 1% 1% 1% 5% 3% 3% Case I2 I2 I2 I2 I2 I2 H H H H H H NOTES: 1. The single output voltage is set to 1% ,dual output voltage is set to 2% at rated load. Voltage balance for dual output at rated load is 2% max.. 2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to the output cable. Peak to peak and RMS metering equipment shall have a 20 MHz response with probes and cables maintaining frequency response from 200 Hz to 100MHz band width. Output ripple and spikes are measured directly at the output terminals of the power supply without the use of the probe ground clip. 3. Load regulation is measured at 115VAC or 230VAC input , while the output being measured is loaded 25% to 100% of rated load. All other outputs at rated load. PHYSICAL SPECIFICATIONS Weight : Case I2:270g, Case H:420g Case Material : Non conductive black plastic NOTES: 1. All dimensions in inches(mm). 2. Tolerance: .xx = 0.04 .xxx = 0.020 UNIVERSAL MICROELECTRONICS