UP030( )A-( )( )(I)(H) SERIES
30 Watt AC/DC Switching Modules
Small Size
Universal Input 90 to 264 VAC
Conductive EMI Meets FCC/CISPR 22 Class B
Designed to Meets UL,CSA,TUV Safety Standards
SPECIFICATIONS
All specifications are typical at nominal line, full load and
25°C unless otherwise noted.
INPUT SPECIFICATIONS
Input Voltage Range …………………….……… 90-264VAC
Input Frequency …………………………….……… 47-63 Hz
Inrush Current …………..…….…… 30A max.(Cold Start)
Line Regulation1……………….…..……± 1%
GENERAL SPECIFICATIONS
Hold-up Time…………….……….…….…….… 16mS typ.
Short Circuit Protection …………………………. Continuous
Overvoltage Protection……………….….5VDC Output Only
Hi-pot Isolation: Input/ Output………………..……4242 VDC
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature Range ……….……. 0°C to 50°C
Derating 40°C to 5C………….. 2%/°C
Temperature Coefficient ± 0.02%/°C
Storage Temperature Range …………..…. –40°C to +85°C
Humidity, Non-Condensing ……………… 0 to 95% RH
Cooling …………………………………. Free- Air Convection
EMI Filter(on Board):
Conducted ……………….…. Meets FCC/CISPR 22 Class B
Specification
NOTE
1. Measured from 90 to 264 VAC.
OUTPUT SPECIFICATIONS
Load Regulation3
Model Number Output Voltage1
(Volts) Output Current
(mA) Ripple2P-P
(mV) Efficiency
(%) Load Change
25-100% Case
UP0301A-01I
UP0301A-02I
UP0301A-03I
UP0302A-01I
UP0302A-02I
UP0302A-03I
5
12
15
± 5
± 12
± 15
5000
2500
2000
± 2500
± 1250
± 1000
50
120
150
50
120
150
69
75
75
69
75
75
± 1%
± 1%
± 1%
± 5%
± 3%
± 3%
I2
I2
I2
I2
I2
I2
UP0301A-01H
UP0301A-02H
UP0301A-03H
UP0302A-01H
UP0302A-02H
UP0302A-03H
5
12
15
± 5
± 12
± 15
5000
2500
2000
± 2500
± 1250
± 1000
50
120
150
50
120
150
69
75
75
69
75
75
± 1%
± 1%
± 1%
± 5%
± 3%
± 3%
H
H
H
H
H
H
NOTES:
1. The single output voltage is set to ±1% ,dual output voltage is set to ±2% at rated load. Voltage balance for dual output at rated load is 2%
max..
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to the output cable. Peak to peak and RMS metering equipment shall have a 20
MHz response with probes and cables maintaining frequency response from 200 Hz to 100MHz band width. Output ripple and spikes are
measured directly at the output terminals of the power supply without the use of the probe ground clip.
3. Load regulation is measured at 115VAC or 230VAC input , while the output being measured is loaded 25% to 100% of rated load. All other
outputs at rated load.
PHYSICAL SPECIFICATIONS
Weight : Case I2:270g, Case H:420g
Case Material : Non conductive black plastic
NOTES:
1. All dimensions in inches(mm).
2. Tolerance: .xx 0.04
.xxx =± 0.020
UNIVERSAL
MICROELECTRONICS