Digital Fiber Sensors E3X-DA-S/MDA OMRON's Next-generation Platform for a Wide Range of Detection Features a Power Tuning function that optimizes light reception at the press of a button. Combines newly developed 4-element LEDs with an APC circuit to ensure stable, long-term LED performance. Utilizes OMRON's innovative wire-saving connector. 2-channel models achieve the thinnest profile in the industry, at only 5 mm per channel. 2-channel models also offer AND/OR control output. Be sure to read Safety Precautions on page 15. Features Equipped with an Industry's First Power Tuning (Optimum Light Setting) Function The E3X-DA-S/MDA features a Power Tuning function that optimizes power at the press of a button. This function easily but securely resolves saturation due to short sensing distances or insufficient incident light due to long sensing distances. In addition, the response speed does not change as mode selection has tuned the power. Conventional New proposal Incident level Threshold High-speed mode Incident level Low Short-range mode Appropriate Standard mode Appropriate Long-range mode Saturation Super-long-range mode Saturation Up to approx. 5 times Press Modeless Up to approx. 1/25 times Available without mode setting. Press the MODE key once to adjust high or low incident levels to be appropriate. Selected from various power mode according to applications Adoption of Newly Developed 4-Element LEDs and an APC (Auto Power Control) Circuit Achieves Long-term Reliable Detection at the Highest Level in the Industry Newly developed 3-element LEDs + APC 4-element LEDs + APC Incident level Conventional Incident level The long-term reliable detection at the highest level in the industry is achieved with the innovative APC circuit whose performance is proved by E3X-DA-N series and the newly developed high-power LEDs (4-element type) to ensure super stable, long-term LED performance. Stable performance is always available without the ON/OFF setting of an APC circuit. Long-term stability No APC circuit No APC circuit Time Time OMRON's Innovative Wire-saving Connector Inherited from the E3X-DA-N Wire-saving Connector Model Reduced Wiring and Space Requirements for Power Lines Up to 16 amplifier units connectable Amplifier units with connectors No relay connector required Clear Optical communications Power supply pin Master connector Slave connector The power is supplied from a master unit to slave units via a master connector. 7 lines Relay connector installation work, cost and space are saved. Output lines Amplifier units with cables Power line Only output lines 1. Greatly reduced wiring work 2. Improved space usability due to the unnecessity of relay connectors 3. Simple stock management due to the unnecessity of distinction between master and slave for amplifiers Power and output lines are required respectively. 15 lines Power lines The amplifier units with connectors supply the power to slave connectors via a master connector. This offers three following advantages. Relay connector 1 E3X-DA-S/MDA Models available for a wide variety of applications at manufacturing sites Industry Leading Two Amplifiers Loaded in a Small Body . . . . 2-channel models Two amplifiers are loaded in a 10 mm-wide body. Liquid crystal board installation and alignment check Space usability can be approximately doubled. In addition, approximately 40% of the energy can be saved. (compared to the value per channel of the former model) 20mm Simpler Digital Fiber Sensors 10mm 2-channel models E3X-MDA . . . . Simple & Easy Single-function Models UP/DOWN keys Threshold value adjustment Current value Threshold value Required performance and functions have been reviewed from basic points to improve high-performance but hard-to-use digital models. Digital fiber sensors, used in the sense as if using volume type sensors, are added to the basic functions such as an APC function and digital display. Key lock switch Operation mode selection switch TEACH key Threshold value teaching Yes/No: Teaching at two points to be detected Automatic: Automatic teaching by feeding workpieces Analog Control Output . . . .Advanced Analog Output Models High-speed and High Resolution The voltage in the range of 1 to 5 V is output according to the incident level (digital display). Wide variety of applications is possible including positioning control or difference detection with multiple levels. Detection modes can be switched in accordance with applications. High-speed response of 80 Ps (super-high-speed mode) supports the positioning controls that require high-speed control. High-speed and High-resolution Analog Output Supports Wide Variety of Applications Sheet Displacement ON/OFF Analog Area Output Function Area Judgment Is Possible . . . .Advanced, Twinoutput Models Only one sensor is enough for area judgment for height or others that has required multiple sensors. Area Output Tablet length detection Incident level 2000 Threshold value 1 1000 Threshold value 2 Setting two threshold values allows easy output inside and outside range. Time Output ON OFF Remote Input Function Sensors Controlled from Outside . . . .Advanced, External- Sticker detection input Models Remote settings for teaching/power tuning/light OFF are possible with input signals. The remote input function meets the diversifying demands such as remote settings made for frequent teaching due to level change corresponding to workpiece change or remote operation check of sensors before operation. Equipped with an Industry's First ATC Function that Resolves Problems at Manufacturing Sites . . . .Advanced ATC Models OMRON's unique algorism is equipped to Fixed Threshold Value Method (Conventional Models) Corrected Threshold Value Method (ATC Models) distinguish dust or dirt and the change of Threshold value 2000 2000 -10% 1800 set as a relative workpieces. Automatic correction of threshold Threshold value value set as an values by sensors in accordance with changes Incident level Incident level absolute value (digital value) prevents malfunctions and improves the operating (digital value) Threshold value is corrected every 30 seconds * rates of machines. The ATC function is especially Malfunctions are prevented Malfunction Adjustment is required effective for the applications that require highTime Time resolution detection. ON ON Output Output OFF OFF * Monitoring range is defined in sensors according to threshold values. Threshold values are corrected in this definition range. 2 E3X-DA-S/MDA Ordering Information Amplifier Units Amplifier Units with Cables Item Appearance Model Functions Single-function models --- Standard models Green LED Mark-detecting models (multiple color light sourc- Blue LED es) Infrared LED External-input models Twin-output models Advanced models ATC function models Analog output models Timer, Response speed change NPN output PNP output E3X-DA11SE-S E3X-DA41SE-S E3X-DA11-S E3X-DAG11-S E3X-DAB11-S E3X-DAH11-S E3X-DA41-S E3X-DAG41-S E3X-DAB41-S E3X-DAH41-S Remote setting, counter, differential E3X-DA11RM-S operation Area output, self-diagnosis, differential E3X-DA11TW-S operation ATC (Threshold value automatic correcE3X-DA11AT-S tion) 2-channel models E3X-DA41RM-S E3X-DA41TW-S E3X-DA41AT-S Analog output models E3X-DA11AN-S E3X-DA41AN-S AND/OR output E3X-MDA11 E3X-MDA41 Amplifier Units with Connectors Item Appearance Model Functions Single-function models Standard models --- NPN output E3X-DA6SE-S E3X-DA6-S E3X-DAG6-S E3X-DAB6-S E3X-DAH6-S PNP output E3X-DA8SE-S E3X-DA8-S E3X-DAG8-S E3X-DAB8-S E3X-DAH8-S Green LED Mark-detecting models (multiple color light sourc- Blue LED es) Infrared LED External-input models Twin-output Advanced models models ATC function models Remote setting, counter, differential operation Area output, self-diagnosis, differential operation ATC (Threshold value automatic correction) E3X-DA6RM-S E3X-DA8RM-S E3X-DA6TW-S E3X-DA8TW-S E3X-DA6AT-S E3X-DA8AT-S 2-channel models AND/OR output E3X-MDA6 E3X-MDA8 Timer, Response speed change Ratings and Specifications Light source Single-function models Standard models Mark-de- E3X-DA@G-S 3X-DA@B-S tecting models E3X-DA@H-S Twin-output models External-inAdput models vanced models ATC function models Red LED Green LED 50Ps to 4ms Blue LED Infrared LED Only main 50Ps to 4ms Only main --- Red LED Main + sub 130Ps to 4ms (2 lines) Only main Main + main 130Ps to 4ms (2 independent lines) Timer --- Functions Interference Differential prevention detection counter ATC --- --- --- --- --- --- ----- --- 80Ps to 4ms Red LED --- Power tuning --- (1 line) 80Ps to 4ms Analog output 2-channel models Control output/input ON/OFF Analog Input output output 1ms Only ----main 50Ps to 4ms Response time --(1 line) --- --- ----- ----- --- 3 E3X-DA-S/MDA Amplifier Unit Connectors (Order Separately) Item Cable length Appearance No. of conductors Model 3 E3X-CN11 4 E3X-CN21 1 E3X-CN12 2 E3X-CN22 Master Connector 2m Slave Connector Combining Amplifier Units and Connectors Amplifier Units and Connectors are sold separately. Refer to the following tables when placing an order. Model Single-function models Standard models Mark-detecting models (multiple color light sources) Advanced models 2-channel models Amplifier Unit NPN output E3X-DA6SE-S E3X-DA6-S Applicable Connector (Order Separately) Master Connector Slave Connector PNP output E3X-DA8SE-S E3X-DA8-S E3X-DAG6-S E3X-DAG8-S E3X-DAB6-S E3X-DAB8-S E3X-DAH6-S E3X-DAH8-S E3X-DA6TW-S E3X-DA6RM-S E3X-DA6AT-S E3X-MDA6 E3X-DA8TW-S E3X-DA8RM-S E3X-DA8AT-S E3X-MDA8 + E3X-CN11 E3X-CN12 E3X-CN21 E3X-CN22 When Using 5 Amplifier Units Amplifier Units (5 Units) + 1 Master Connector + 4 Slave Connectors Mobile Console (Order Separately) Appearance Model Remarks E3X-MC11-SV2 (model number of set) Mobile Console with Head, Cable, and AC adapter provided as accessories E3X-MC11-C1-SV2 Mobile Console E3X-MC11-H1 Head E39-Z12-1 Cable (1.5 m) Note: Use the E3X-MC11-SV2 Mobile Console for the E3X-DA-S/MDA-series Amplifier Units. The E3X-MC11-SV2 is an upgraded version of the E3X-MC11-S that is fully interchangeable with the older model. Accessories (Order Separately) Mounting Bracket Appearance End Plate Model E39-L143 Quantity 1 Appearance Model PFP-M Quantity 1 4 E3X-DA-S/MDA Ratings and Specifications Refer to pages 17 to 20 for dimensions. Amplifier Units Type Single-function models Standard models Mark-detecting models (multiple color light sources) Green LED Blue LED Infrared LED E3X-DAG@-S E3X-DAB@-S E3X-DAH@-S Green LED (525 nm) Blue LED (470 nm) Infrared LED (870nm) Item Model E3X-DA@SE-S E3X-DA@-S Light source (wavelength) Red LED (635 nm) Power supply voltage 12 to 24 VDC 10%, ripple (p-p) 10% max. Power consumption 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC) Load power supply voltage: 26.4 VDC; NPN/PNP open collector; Control output load current: 50 mA max.; residual voltage: 1 V max. Protection circuits Reverse polarity for power supply connection, output short-circuit Super-high-speed mode --Operate: 48 s, reset: 50 s *1, *2 --Operate/reset: 250 s Response High-speed mode time Standard mode Operate or reset: 1 ms High-resolution mode --Operate or reset: 4 ms Sensitivity setting Teaching or manual method Power tuning --Light emission power and reception gain, digital control method Select from OFF-delay, ON-delay, or one-shot timer. Timer function --1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments) Automatic power High-speed control method for emission current Functions control (APC) Zero-reset --Negative values can be displayed. (Threshold value is shifted.) Initial reset Settings can be returned to defaults as required. Mutual interferPossible for up to 10 Units *3 ence prevention Operation indicator Display Operation indicator (orange), Power Tuning indicator (orange) (orange) incident level + Digital display Select from incident level + threshold or other 6 patterns threshold Display orientation --Switching between normal/reversed display is possible. Ambient illumination Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max. (Receiver side) Ambient temperature range Ambient humidity range Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Connection method Weight (packed state) Case Materials Cover Accessories Operating: Groups of 1 to 2 Amplifiers: -25C to 55C Groups of 3 to 10 Amplifiers: -25C to 50C Groups of 11 to 16 Amplifiers: -25C to 45C Storage: -30C to 70C (with no icing or condensation) Operating and storage: 35% to 85% (with no condensation) 20 M min. (at 500 VDC) 1,000 VAC at 50/60 Hz for 1 minute Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions Destruction: 500 m/s2, for 3 times each in X, Y and Z directions IEC 60529 IP50 (with Protective Cover attached) Pre-wired or amplifier unit connector Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g Polybutylene terephthalate (PBT) Polycarbonate (PC) Instruction manual *1. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention and the Mobile Console will not function. *2. PNP output is as follows: Operate: 53 s, reset: 55 s. *3. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled. 5 E3X-DA-S/MDA Advanced models 2-channel models External input models Twin output models ATC function models Analog output models Item Model E3X-DA@RM-S E3X-DA@TW-S E3X-DA@AT-S E3X-DA@AN-S E3X-MDA@ Light source (wavelength) Red LED (635 nm) Power supply voltage 12 to 24 VDC 10%, ripple (p-p) 10% max. Power consumption 1,080mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC) Load power supply voltage: 26.4 VDC; NPN/PNP open collector; ON/OFF output load current: 50 mA max.; residual voltage: 1 V max. Control output Voltage output: 1 to 5 VDC (Connection load 10 k: min.) Temperature characteristics Control 0.3%F.S./C output Response speed/ --Analog output --repeat accuracy Super-high-speed mode: 80 Ps/1.5%F.S. High-speed mode: 250 Ps/1.5%F.S. Standard mode: 1 ms/1%F.S. High-resolution mode: 4 ms/0.75%F.S. Protection circuits Reverse polarity for power supply connection, output short-circuit Operate: 48 Ps, Operate or reset: Operate or reset: Operate or reset: Operate or reset: Super-high-speed mode reset: 50 Ps *1, *2, *3 80Ps *1 130 Ps *1 80 Ps *1 130 Ps *1, *4 Response High-speed mode Operate or reset: 250 Ps Operate or reset: 450 Ps time Standard mode Operate or reset: 1ms High-resolution mode Operate or reset: 4ms Sensitivity setting Teaching or manual method Power tuning Light emission power and reception gain, digital control method Switchable between single edge and double edge detection mode Differential deSingle edge: Can be set to 250 Ps, 500 Ps, 1 ms, 10 ms, or 100 ms. --tection Double edge: Can be set to 500 Ps, 1 ms, 2 ms, 20 ms, or 200 ms. Select from OFF-delay, ON-delay, or one-shot timer. Timer function 1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100ms increments, and 1 to 5 s set in 1 s-increments) Automatic power High-speed control method for emission current control (APC) Zero-reset Negative values can be displayed. (Threshold value is shifted.) Initial reset Settings can be returned to defaults as required. Functions Mutual interferPossible for up to 9 Possible for up to 10 Units *5 ence prevention Units (18 channels) *6 Switchable between up counter and down Counter counter. --Set count: 0 to 9,999,999 External input setOutput setting (SeOutput setting Output setting ting (Select from lect from channel 2 (Select from channel (Select from channel Analog output setteaching, power tunoutput, area output, 2 output, AND, OR, I/O setting 2 output, area outting (offset voltage ing, zero reset, light self-diagnosis outleading edge sync, put, or self-diagnoadjustable) OFF, or counter reput, or ATC error falling edge sync, or sis.) set.) output) differential output) Operation indicator Operation indicator Operation indicator for (orange), Power Operation indicator for channel 1 (orange), (orange), channel 1 (orange), Display Tuning indicator (or- Operation indicator for channel 2 (orange) Power Tuning indiOperation indicator for ange) cator (orange) channel 2 (orange) Type *1. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention and the Mobile Console will not function. *2. PNP output is as follows: Operate: 53 Ps, reset: 55 Ps. *3. When counter is enabled: 80 Ps for operate and reset respectively. *4. When differential output is selected for the output setting, the second channel output is 200 Ps for operation and reset respectively. *5. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled. *6. Mutual interference prevention can be used for up to 5 Units (10 channels) if power tuning is enabled. 6 E3X-DA-S/MDA Advanced models External input models Twin-output models ATC function models Analog output models Model E3X-DA@RM-S E3X-DA@TW-S E3X-DA@AT-S E3X-DA@AN-S Type Item Select from incident level + threshold or other 7 patterns Digital display Display orientation Ambient illumination (Receiver side) Ambient temperature range Ambient humidity range Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Connection method Weight (packed state) Case Materials Cover Accessories Select from incident level + threshold or other 6 patterns Model E3X-MDA@ Select from incident level for channel 1 + incident level for channel 2 or other 7 patterns Switching between normal/reversed display is possible. Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max. Operating: Groups of 1 to 2 Amplifiers: 25C to 55C Groups of 3 to 10 Amplifiers: 25C to 50C Groups of 11 to 16 Amplifiers: 25C to 45C Storage: 30C to 70C (with no icing or condensation) Operating and storage: 35% to 85% (with no condensation) 20 M: min. (at 500 VDC) 1,000 VAC at 50/60 Hz for 1 minute Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions Destruction: 500 m/s2, for 3 times each in X, Y and Z directions IEC 60529 IP50 (with Protective Cover attached) Pre-wired or amplifier unit connector Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g Polybutylene terephthalate (PBT) Polycarbonate (PC) Instruction manual Mobile Console Amplifier Unit Connectors Item 2-channe models E3X-CN11/21/22 E3X-CN12 Item Model E3X-MC11-SV2 Rated current 2.5 A Rated voltage 50 V Applicable Sensors Contact resistance 20 m: max. (20 mVDC max., 100 mA max.) (The figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.) E3X-DA-S E3X-MDA E3C-LDA E2C-EDA Power supply voltage Charged with AC adapter No. of insertions Destruction: 50 times (The figure for the number of insertions is for connection to the Amplifier Unit and the adjacent Connector.) Connection method Connected via adapter Mate- Housing rials Contacts Polybutylene terephthalate (PBT) Weight Approx. 580 g (Console (packed state) only: 120 g) Weight (packed state) Approx. 55 g Phosphor bronze/gold-plated nickel Approx. 25 g Refer to Instruction Manual provided with the Mobile Console for details. 7 E3X-DA-S/MDA Sensing Distance Through-beam Models (Unit: mm) Model Type Flexible (new standard) Standard models Standard Breakresistant Specialbeam models E32-T11R/E32-T12R/E32-T15XR/ E32-TC200BR(B4R) E32-T14LR/E32-T15YR/E32-T15ZR E32-T21R/E32-T22R/E32-T222R/ E32-T25XR/E32-TC200FR(F4R) E32-T24R/E32-T25YR/E32-T25ZR E32-TC200/E32-T12/E32-T15X/ E32-TC200B(B4) E32-T14L/E32-T15Y/E32-T15Z E32-TC200A E32-TC200E/E32-T22/E32-T222/ E32-T25X/E32-TC200F(F4) E32-T24/E32-T25Y/E32-T25Z E32-T11/E32-T12B/E32-T15XB E32-T21/E32-T221B/E32-T22B E32-T25XB Fluorine coating E32-T11U Longdistance, high power E32-T17L E32-TC200 + E39-F1 E32-T11R + E39-F1 E32-T11 + E39-F1 E32-T14 E32-T11L/E32-T12L E32-T11L + E39-F2 E32-T11R + E39-F2 E32-T11 + E39-F2 E32-T21L/E32-T22L Ultracompact, ultrafine sleeve E3X-DA@-S E3X-MDA@ Highresolution mode Standard mode Highspeed mode Superhighspeed mode Highresolution mode Standard mode Highspeed mode Superhighspeed mode 700 530 350 140 450 350 230 140 270 210 130 50 170 130 85 50 160 130 75 30 100 75 50 30 60 50 25 10 35 27 18 10 1,000 760 500 200 650 500 330 200 600 900 460 680 300 450 120 180 390 580 300 450 200 300 120 180 270 220 125 50 170 130 85 50 160 900 240 180 130 680 200 150 75 450 110 85 30 180 45 35 100 580 150 125 70 450 110 95 45 300 70 60 30 180 45 35 900 680 450 180 580 450 300 180 4,000 13,000 10,000 1,500 4,000 3,700 970 3,100 2,400 930 3,000 2,300 900 2,900 2,200 350 1,100 870 180 600 520 100 330 260 160 530 430 100 340 260 6,500 2,400 1,600 1,500 1,450 580 340 170 280 170 4,000 1,500 970 930 900 350 180 100 160 100 20,000*1 20,000*1 10,000 4,000*2 4,000*2 2,600 4,000*2 3,700 2,400 4,000*2 3,600 2,300 4,000*2 3,400 2,250 1,700 1,330 870 910 800 500 520 400 250 820 660 430 540 440 250 E32-T223R 160 130 75 30 110 85 55 30 E32-T33-S5 53 44 25 10 35 28 18 10 E32-T333-S5 12 10 6 4 8 6 5 4 E32-T334-S5 6 5 3 2 4 3 2 2 E32-T22S 2,500 1,900 1,250 500 1,600 1,250 830 500 E32-T24S 1,750 1,300 870 350 1,100 870 580 350 1,100 1,500 980 1,300 1,700 2,300 3,700 750 840 1,100 750 1,000 1,300 1,800 2,800 610 560 750 480 650 850 1,150 1,850 350 220 300 190 260 340 450 740 140 730 970 600 800 1,100 1,400 2,400 470 560 750 480 650 860 1,100 1,800 360 370 500 320 430 570 730 1,200 240 220 300 190 260 340 450 740 140 Fine beam E32-T16PR E32-T16P E32-T16JR E32-T16J Area sensing E32-T16WR E32-T16W E32-T16 E32-M21 *1. The optical fiber for the E32-T17L is 10 m long on each side, so the value is 20,000 mm *2. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm. 8 E3X-DA-S/MDA Model Type Heatresistant Environment resistive models Chemical resistant Vacuum resistant E3X-DA@-S Highresolution mode 1,000 300 360 600 4,000 1,750 600 2,500 4,000* 500 1,800 920 260 1,350 210 660 630 E32-T51 E32-T54 E32-T81R-S E32-T61-S + E39-F2 E32-T61-S + E39-F1 E32-T84S-S E32-T61-S E32-T11F E32-T12F E32-T14F E32-T51F E32-T81F-S E32-T51V E32-T51V + E39-F1V E32-T54V E32-T54V + E39-F1V E32-T84SV Standard mode Highspeed mode 760 230 280 450 3,400 1,300 450 2,000 3,000 400 1,400 700 200 1,000 130 500 480 500 150 180 300 2,200 870 300 1,300 2,000 250 900 460 130 680 100 330 320 E3X-MDA@ Superhighspeed mode 200 60 70 120 900 350 120 520 800 100 350 190 50 260 35 180 130 Highresolution mode 650 190 230 390 3,000 1,100 390 1,600 2,600 320 1,190 600 170 850 110 420 410 Standard mode Highspeed mode 500 150 180 300 2,200 870 300 1,300 2,000 250 920 460 130 650 85 320 310 330 100 120 200 1,450 570 200 850 1,300 160 600 300 85 430 55 210 200 Superhighspeed mode 200 60 70 120 900 350 120 520 800 100 350 190 50 260 35 180 130 * The optical fiber for the E32-T12F is 2 m long on each side, so the sensing distance is 4,000 mm. Reflective Models (Unit: mm) Model Type Flexible (new standard) Standard models Standard Breakresistant Fluorine coating E32-D11R/E32-D12R/E32-D15XR/ E32-DC200BR(B4R) E32-D14LR E32-D15YR/E32-D15ZR E32-D211R/E32-D21R/E32-D22R/ E32-D25XR/E32-DC200FR(F4R) E32-D24R E32-D25YR/E32-D25ZR E32-DC200/E32-D15X/ E32-DC200B(B4) E32-D12 E32-D14L E32-D15Y/E32-D15Z E32-D211/E32-DC200E/E32-D22/ E32-D25X/E32-DC200F(F4) E32-D24 E32-D25Y/E32-D25Z E32-D11/E32-D15XB E32-D21B/E32-D221B E32-D21/E32-D22B E32-D25XB E32-D11U E3X-DA@-S Highresolution mode Standard mode 300 170 120 80 70 45 40 50 E3X-MDA@ SuperHighhighspeed speed mode mode Highresolution mode Standard mode Highspeed mode Superhighspeed mode 50 170 120 80 50 30 26 14 12 45 40 33 29 22 19 14 12 30 20 8 30 22 14 8 26 14 15 8 10 5 4 2 15 8 10 5 6 3.3 4 2 500 300 200 90 300 210 130 90 400 200 170 230 110 100 160 80 65 70 36 30 230 110 100 160 80 70 100 50 45 70 36 30 130 80 50 22 80 55 35 22 50 35 300 110 50 85 30 20 170 70 30 50 20 12 120 45 20 30 8 6 50 20 8 15 30 20 170 70 30 50 22 14 125 50 22 35 14 9 80 30 14 23 8 6 50 20 8 15 300 170 120 50 170 125 80 50 9 E3X-DA-S/MDA Model Type E32-D16 Long distance, high power Ultracompact, ultrafine sleeve Environmentresistive models Heatresistant Chemicalresistant 40 to 700 40 to 450 40 to 240 Standard mode Highspeed mode Superhighspeed mode 40 to 600 40 to 490 40 to 300 40 to 240 400 260 110 400 270 180 110 E32-D21L/E32-D22L 210 130 80 35 130 85 55 35 E32-D33 25 16 10 4 16 10 6 4 E32-D331 5 3 2 0.8 3 2 1.3 0.8 E32-C41 + E39-F3A-5 E32-C31 + E39-F3A-5 E32-C41 + E39-F3B E32-C31 + E39-F3B E32-C31 + E39-F3C Area sensing E32-D36P1 Convergentreflective 40 to 1,000 Highresolution mode 650 E32-C42 + E39-F3A Coaxial/small E32-D32 + E39-F3A spot Retroireflective Standard mode E3X-MDA@ SuperHighhighspeed speed mode mode E32-D11L E32-CC200R E32-CC200 E32-D32L E32-C31/E32-D32 Specialbeam models E3X-DA@-S Highresolution mode 250 150 100 45 150 105 65 45 500 300 200 90 300 210 140 90 250 150 100 45 150 100 65 45 120 75 50 22 75 50 30 22 Spot diameter variable in the range 0.1 to 0.6 mm at distances in the range 6 to 15 mm. Spot diameter variable in the range 0.5 to 1mm at distances in the range 6 to 15 mm. 0.1-mm dia. spot at a distance of 7 mm. 0.5-mm dia. spot at a distance of 7 mm. 0.2-mm dia. spot at a distance of 17 mm. 0.5-mm dia. spot at a distance of 17 mm. Spot diameter of 4 mm max. at distances in the range 0 to 20 mm. 250 150 100 45 150 100 65 45 E32-R21 + E39-R3 (provided) 10 to 250 E32-R16 + E39-R1 (provided) 150 to 1,500 E32-L25/E32-L25A E32-L24S E32-L24L E32-L25L E32-L86 E32-L16 E32-D51 E32-D81R-S E32-D61-S E32-D73-S 3.3 0 to 4 2 to 6 (center 4) 5.4 to 9 (center 7.2) 4 to 10 0 to 12 0 to 15 160 72 230 165 400 0 to 15 230 110 0 to 12 72 150 90 60 27 90 63 40 27 100 60 40 18 60 40 25 18 E32-D12F 160 95 65 30 95 70 45 30 E32-D14F 70 40 30 10 40 28 18 10 10 E3X-DA-S/MDA Application-specific Models (Unit: mm) Model E3X-DA@-S Highresolution mode Type Label detection Liquid-level detection Standard mode E32-G14 E32-T14 Wafer mapping Highspeed mode Superhighspeed mode 4,000* 3,400 2,250 900 2,900 2,200 1,450 900 Applicable tube: Transparent tube with a diameter in the range 8 to 10 mm and a recommended wall thickness of 1 mm E32-D36T Applicable tube: Transparent tube (no restriction on diameter) E32-A01 Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm and a recommended wall thickness of 1 mm Applicable tube: Transparent tube with a diameter in the range 6 to 13 mm and a recommended wall thickness of 1 mm Liquid-contact model E32-L16 0 to 15 0 to 12 0 to 15 0 to 12 E32-A08 10 to 20 --- 10 to 20 --- E32-A07E1(E2) 15 to 25 --- 15 to 25 --- E32-L66 Glasssubstrate Mapping Standard mode 10 E32-D82F1(F2) Glasssubstrate alignment Highresolution mode E32-L25T E32-A02 Applicationspecific models E3X-MDA@ SuperHighhighspeed speed mode mode 5 to 18 5 to 16 --- 5 to 18 5 to 14 --- E32-A09/E32-A09H 15 to 38 --- 15 to 38 --- E32-A09H2 20 to 30 --- 20 to 30 --- E32-A03/E32-A03-1 1,150 890 600 250 750 580 380 250 E32-T24S 1,750 1,300 870 350 1,100 870 580 350 460 340 225 100 300 220 145 100 E32-A04/E32-A04-1 * The optical fiber for the E32-T14 is 2 m long on each side, so the sensing distance is 4,000 mm. 11 E3X-DA-S/MDA Green, Blue, and Infrared Light Sources (Unit: mm) Model Type Throughbeam models Reflective models Applicationspecific models E32-T11R/E32-T12R/E32-T15XR/ E32-TC200BR(B4R) E32-T14LR/E32-T15YR/ E32-T15ZR Standard E32-TC200/E32-T12/E32-T15X/ E32-TC200B(B4) E32-T14L/E32-T15Y/E32-T15Z Special beam E32-T11L/E32-T12L E32-D11R/E32-D12R/E32-D15XR/ E32-DC200BR(B4R) E32-D14LR E32-D15YR/E32-D15ZR Standard E32-DC200/E32-D15X/ E32-DC200B(B4) E32-D14L E32-D15Y/E32-D15Z E32-D11L E32-CC200R Special beam E32-CC200 E32-D32L E32-C31/E32-D32 Label detection E32-T14 E32-G14 E3X-DAG@-S/DAB@-S HighSuperStan- Highresohighdard speed lution speed mode mode mode mode E3X-DAH@-S Highresolution mode Standard mode Highspeed mode Superhighspeed mode 65 50 35 30 280 190 130 55 25 20 22 12 100 75 80 21 100 75 50 45 400 280 180 80 50 150 40 120 30 85 25 75 240 700 160 490 110 320 45 140 17 14 10 8 120 90 60 21 4.4 4.2 3.5 3.3 2.5 2.2 2.2 2.1 32 28 24 20 16 13 5.5 5 32 25 16 16 200 150 100 35 11 10 44 15 32 15 7.5 9 8 35 12 25 12 6 6 5.5 22 8 16 8 4 5.5 5 22 7.5 16 7.5 3.5 80 65 260 100 200 100 50 60 50 190 75 150 75 37 40 33 130 50 100 50 25 14 11 45 17 35 17 8.5 320 260 220 160 1,800 1,200 820 360 10 10 Refer to E32 Series for details on Fiber Units. 12 E3X-DA-S/MDA Dimensions (Unit: mm) Amplifier Units Amplifier Units with Cables E3X-DA11-S E3X-DA41-S E3X-DAG11-S E3X-DAG41-S E3X-DAB11-S E3X-DAB41-S E3X-DA11RM-S E3X-DA41RM-S E3X-DA11TW-S E3X-DA41TW-S E3X-DA11SE-S E3X-DA41SE-S E3X-DA11AT-S E3X-DA41AT-S E3X-DA11AN-S E3X-DA41AN-S E3X-MDA11 E3X-MDA41 Operation indicator Round ( ): Power tuning indicator Oblong ( ): Operation indicator for channel 2 Main display Sub-display Vinyl-insulated round cable Standard length: 2 m* CH2 CH1 (E3X-DA@-S) (E3X-MDA@) *Cable Specifications E3X-DA11-S -DA41-S -DAG11-S -DAG41-S -DAB11-S -DAB41-S 4-dia., 3-conductor (Conductor cross section: 0.2 mm2, insulator diameter: 1.1 mm) E3X-DA11TW-S -DA41TW-S -DA11RM-S -DA41RM-S 4-dia., 4-conductor (Conductor cross section: 0.2 mm2, insulator diameter, 1.1 mm) E3X-MDA11 -MDA41 4-dia., 2-conductor (Conductor cross section: 0.2 mm2, insulator diameter: 1.1 mm) With Mounting Bracket Attached 3.9 x 3 = 11.7 32.8 29.8 3.9 x 3 15.1 =11.7 12.15 3.25 * The Mounting Bracket can also be used on this side. 4.3 10 10 A* 70 Two, 2.4 dia. 4.5 32 Four, 2.4 dia. 7 4.5 4.5 5.65 5.65 (E3X-DA@-S) 9.9 12.5 3.4 (E3X-MDA@) 28.1 18.7 16 34.8 Hole for optical communications 44.3 Two, 3.2 dia. holes 3.4 Two, M3 16 28.1 Mounting Bracket (E39-L143) SUS304 stainless steel 4.4 16 Mounting Holes 17 E3X-DA-S/MDA Amplifier Units with Connectors E3X-DA6-S E3X-DA8-S E3X-DAG6-S E3X-DAG8-S E3X-DAB6-S E3X-DAB8-S E3X-DA6RM-S E3X-DA8RM-S CH2 E3X-DA6TW-S E3X-DA8TW-S E3X-DA6SE-S E3X-DA8SE-S E3X-DA6AT-S CH1 E3X-DA8AT-S (E3X-DA@-S) E3X-MDA6 E3X-MDA8 Round ( ): Power tuning indicator Oblong ( ): Operation indicator for channel 2 Operation indicator Main display Sub-display (E3X-MDA@) *1 The Mounting Bracket can also be used on this side. *2 Cable Diameters With Mounting Bracket Attached 3.9 x 3 = 11.7 32.8 29.8 3.9 x 3 15.1 =11.75 12.15 3.25 10 10 A *1 E3X-CN22 (2 conductors) E3X-CN21 (4 conductors) E3X-CN11 (3 conductors) 4.0-mm dia. E3X-CN12 (1 conductor) 2.6-mm dia. 70 4.3 8.1 Connector Two, 2.4 dia. Four, 2.4 dia. 4.5 Dia. A*2 32 7 4.5 4.5 5.65 5.65 (E3X-DA@-S) 9.9 12.95 3.4 (E3X-MDA@) 28.1 18.7 16 34.8 44.3 Two, 3.2-dia. holes 3.4 Two, M3 Mounting Bracket (E39-L143) SUS304 stainless steel 4.4 16 Mounting Holes 28.1 Hole for optical communications 16