http://www.tracopower.com Page 1 of 4
AC/DC Enclosed Power Supply TXL 150 Series, 150 Watt
Models
Compact metal case with screw
terminal block
Universal input 85 - 264 Vac
EMI/EMC compliance with EN 61000-6-3
and EN 61000-6-1
Compliance to EN 61000-3-2
Active power factor correction
Short circuit and overvoltage protection
International safety approvals
3 year product warranty
The TRACOPOWER TXL series is a family of encased power supplies designed
for a wide range of cost critical applications. With a low profile metal case and
screw terminal block connection, they are easy to install in any equipment.
These power supplies have universal input and comply with European EMC stan-
dards and the Low Voltage Directive (LVD).
Order Code Power max. Output voltage nom. Output current max. Efficiency typ.
TXL 150-05S 150 W 5 VDC 30.0 A 77 %
TXL 150-12S 150 W 12 VDC 12.5 A 84 %
TXL 150-24S 151 W 24 VDC 6.3 A 85 %
TXL 150-48S 154 W 48 VDC 3.2 A 86 %
Models
C B
Scheme
U L 6 0 950 -1
TXL 150 Series, 150 Watt
http://www.tracopower.com Page 2 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input voltage range – nominal 100 – 240 VAC
– AC range (universal input) 85 – 264 VAC
– DC range 120 – 375 VDC
Input frequency 47 – 63 Hz
Input current at full load – at 100 VAC 2.2 A max.
Input inrush current – at 115 VAC / 230 VAC 35 A max. / 70 A max.
Power Factor Correction (PFC) PF > 0.95
Recommended circuit breaker (characteristic C or slow bow fuse) 10 A
Output Specifications
Output voltage adjustment range ±10 %
Regulation – Input variation 1.0 % max.
– Load variation (20 - 100%) 1.0 % max.
Minimum load not required
Temperature coefficient 0.02 %/K
Start-up time 3 s max.
Rise time 20 ms max.
Hold-up time – at 230 VAC 20 ms min.
Ripple and noise (20Mhz Bandwidth) 5 Vout model: 70 mVp-p typ.
12 Vout model: 120 mVp-p typ.
24 & 48 Vout models: 200 mVp-p typ.
– measured with external capacitors:
0.1 F and 47 F parallel capacitor
Overload protection by current limitation 105 – 150 % of Iout max.
Short circuit protection hiccup mode (automatic recovery)
Overvoltage protection (Latch off, recovery after restart) 115 – 140 % of nominal Vout
Capacitive load www.tracopower.com/products/txl-capload.pdf
General Specifications
Temperature ranges – Operating 20°C to +7C
(with derating)
– Storage
–40°C to +85°C
Output power derating – Temperature 2.5 %/K above +50°C
– Low input voltage 0.7 %/V below 100 VAC
Cooling natural convection (20 lfm), no internal fan
Over Temperature Protection over 90°C thermal shutdown, auto. recovery
Humidity (non condensing) 20 – 90 % rel. H max.
Altitude during operation 2000 m
Isolation voltage (60 sec.) – Input / Output 3000 VAC
– Input / PE 1500 VAC
– Output / PE 500 VAC
Isolation resistance (at 500 VDC) 100 MOhm min.
Leakage current (at 264 VAC/60Hz) 1.5 mA max.
Remote Sense open or connected to the load (RS+, RS–)
Remote on/off – Power On: 0 – 0.7 VDC
– Power Off: 3 – 10 VDC
– Off idle current 3 – 10 mA
TXL 150 Series, 150 Watt
http://www.tracopower.com Page 3 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
General Specifications (continued)
Switching frequency 65 kHz typ. (pulse width modulation)
Reliability (calculated MTBF) > 230‘000 h
Electromagnetic compatibility (EMC), emissions
– Conducted input RI suppression EN 55022 class B, FCC Part 15 level B
– Harmonic current emissions IEC/EN 61000-3-2, class D
– Voltage flicker IEC/EN 61000-3-3
Electromagnets compatibility (EMC), immunity according EN 55024
– Electrostatic discharge ESD IEC/EN 61000-4-2, 4 kV / 8 kV, perf. criteria A
– RF field immunity IEC/EN 61000-4-3, 3 V/m, perf. criteria A
– Electrical fast transients/burst immunity IEC/EN 61000-4-4, ±2 kV, perf. criteria A
– Surge IEC/EN 61000-4-5, 1 kV / 2 kV, perf. criteria A
– Conducted RF IEC/EN 61000-4-6, 3 Vrms perf. criteria A
– Magnetic field IEC/EN 61000-4-8, 3 A/m perf. criteria A
– Voltage dip IEC/EN 61000-4-11
>95 %, perf. criteria A, 0.5 periods
30 %, perf. criteria A, 25 periods
>95 % perf. criteria B, 250 periods
Safety standards UL 60950-1, IEC/EN 60950-1
Safety approvals – UL/cUL www.ul.com → certifications → File: e188913
– CB report www.tracopower.com/overview/txl
Environmental compliance – Reach www.tracopower.com/products/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
Casing material aluminium (chassis and cover)
Weight 0.84 kg
TXL 150 Series, 150 Watt
www.tracopower.com
© Copyright 2020 Traco Electronic AG Specifications can be changed without notice!
Page 4 of 4
Rev. June 8, 2020
Outline Dimensions
RC Remote Control On/Off: RC+/RC–
On = 0 – 0.7 VDC, Off = 3 – 10 VDC
RS Remote Sense: RS+/RS–
Can be open or connected to the load
under regard of polarity.
Connector type: JS-1001R-XX
Remote Connector
198
13 max.
(0.51 max.)
(7.83)
10
(0.39)
28
(1.10)
79
(3.11)
10
(0.39)
168
(6.61)
Vout
L
N
+
+
49.5
(1.95)
2 x M4 thread
(bottom)
65
(2.56)
63
(2.48)
117
(4.61)
56
25
(0.98)
12.5
(0.49)
(2.20)
11.5
(0.45)
(0.83)
21
(0.49)
12.5
176.5
(6.95)
6 x M4 THD
4 x M3 THD
(bottom)
Top view
99
(3.9)
50
(1.97)
V adj.
RC
RS
+
-
-
+
4 TXL-CMB chassis mount
brackets included in shipment
Order Code TXL-CMB
Package contains 4 pcs brackets and screws
Chassis Mount Brackets
17.5
5.6
15.0
16.8
7.5 7.5
15.0
5.012.5
Ø4.2
R0.5
7.5 7.5
5.0 10.0
4x7
R1.0
Dimensions in [mm], () = Inch
Tolerances ±0.5 (±0.02)