GaAs Infrared Emitting Diode
in Side Looking Package
OP142A, OP142B, OP142C, OP142D
OPTEK Technology Inc.— 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (800) 341-4747 FAX: (972) 323– 2396 sensors@optekinc.com www.optekinc.com
Electrical Characteristics (TA = 25°C unless otherwise noted)
Absolute Maximum Ratings
TA = 25o C unless otherwise noted
Storage Temperature Range -40° C to +100° C
Operating Temperature Range -40° C to +85° C
Lead Soldering Temperature [1/16 inch (1.6mm) from case for 5 sec with soldering iron] 260° C(1)
Reverse Voltage 5.0 V
Continuous Forward Current (IF) 50 mA
Power Dissipation 75 mW(2)
Notes:
1. RMA flux is recommended. Duration can be extended to 10 sec when flow soldering. A maximum 5 seconds and 20 grams of force may
be applied to the leads when hand soldering.
2. De-rate linearly at 1.25 mW/° C above 25° C.
SYMBOL PARAMETER MIN MAX UNITS CONDITIONS
EE(APT) Apertured Radiant Incidence
OP142A
OP142B
OP142C
OP142D
0.40
0.30
0.20
0.10
-
0.55
0.40
mW/cm2 IF = 20 mA(3)
VF Forward Voltage 1.2 1.5 V IF = 20 mA
IR Reverse Current 20 µA VR = 10.0V
λp Wavelength at Peak Emission 935 nm IF = 20 mA
ΘHP Emission Angle at Half Power Points 40 Degrees
tr Output Rise Time 1000 ns
tf Output Fall Time 500 ns
IF(PK) = 100mA, PW = 10µs,
Duty Cycle = 10%
IE Radiant Intensity
OP142A
OP142B
OP142C
OP142D
1.12
0.84
0.56
0.28
-
1.54
1.12
-
mW/sr IF = 20 mA
Issue 1.0 09.05
Page 2 of 4
3. EE(APT) is a measurement of the average apertured radiant incidence upon a sensing area 0.180” (4.57 mm) diameter perpendicular to and
centered on the mechanical axis of the lens and 0.653” (16.6 mm) from the lens tip. EE(APT) is not necessarily uniform within the measured
area.