SUNON SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : AXIAL AC FAN DIMENSIONS : 80X80X38 mm MODEL : SF23080A P/N : 2083HBL.GN SUNON SPEC. NO. : A08000560G-00 CUSTOMER : APPROVAL NO. APPROVED BY : CUSTOMER (AUTHORIZED) DRAWN Jeff 06/03 CHECKED Kiddy March APPROVED Jacky SPEC.NO A08000560G-00 ISSUE DATE 05. 10. 2005 EDITION 2 REVISION DATE 06. 03. 2013 E.SPEC EA80035 SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD. TEL:886-7-8135888 NO. 30, LN. 296, XINYA RD., QIANZHEN DIST., KAOHSIUNG CITY 80673, TAIWAN (R.O.C) FAX:886-7-8230505/8230606/8231010 E-mail: sunon@email.sunon.com.twD.C.C. URL:http://www.sunon.com 2013.07.15 SUNON AXIAL AC FAN MODEL : SF23080A P/N : 2083HBL.GN CHARACTERISTICS 1. Motor Design : Reliable Shaded-Pole Motor Construction. 2. Insulation Resistance : 500Megohms minimum at 500 VDC. 3. Dielectric Strength : 1500 VAC for one second . 4. Motor Protection : Impedance protected. 5. Noise Level : Measured in a semi-anechoic chamber with background noise level below 15 dB(A). The fan is running in free air with the microphone at a distance of one meter from the fan intake. 6. Tolerance : 15% on rated power and current. 7. Air Performance : Measured by a double chamber. The values : are recorded when the fan speed has stabilized : at rated voltage. SPEC.NO A08000560G-00 REVISION DATE 06. 03. 2013 ISSUE DATE 05. 10. 2005 E D I T I O N 2 SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD. P A G E 2 OF 9 D.C.C. 2013.07.15 SUNON SPECIFICATIONS MODEL: SF23080A P/N : 2083HBL.GN 1-1. Rated Voltage : 220-240 VAC 50/60 Hz 1-2. Operating Voltage Range : 185-245 VAC 1-3. Starting Voltage : 185 VAC(25 deg. C POWER ON/OFF) 1-4. Rated Speed : 2400/2850 RPM 10% 1-5. Air Delivery : 24/31 CFM 1-6. Static Pressure : 0.13/0.19 Inch-H2O 1-7. Rated Current : 0.09/0.08 AMP 1-8. Rated Power : 14/13.5 WATTS 1-9. Noise Level : 32/36.5 dB(A) 1-10. Direction of Rotation : Counter-clockwise viewed from front of fan blade 1-11. Operating Temperature : -10 to +70 deg. C 1-12. Storage Temperature : -40 to +70 deg. C 1-13. Bearing System : Precision ball bearing system 1-14. Weight : 340g 1-15. Safety : UL/CUR/TUV/CE Approvals 1-16. Protection : Automatic Restart Capability Note: In a situation where the fan is locked by an external force while the electricity is on, an increase in coil temperature will be prevented by temporarily turning off the electrical power to the motor. The fan will automatically restart when the locked rotor condition is released Polarity Protection SPEC.NO A08000560G-00 REVISION DATE 06. 03. 2013 ISSUE DATE 05. 10. 2005 E D I T I O N 2 SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD PAGE 3 OF 9 D.C.C. 2013.07.15 SUNON MODEL : SF23080A P/N : 2083HBL.GN PERFORMANCE CURVES STATIC PRESSURE mm-H2O Inch-H2O 6 0.20 50 HZ 4 60 HZ 0.10 2 0 0 0 20 40 0.57 1.13 CFM m3/min SPEC.NO A08000560G-00 REVISION DATE 06. 03. 2013 ISSUE DATE 05. 10. 2005 E D I T I O N 2 SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD PAGE 4 OF 9 D.C.C. 2013.07.15 SUNON MATERIAL 2. Material 2-1. Frame : DIE-CAST ALUMINUM 2-2. Impeller : Thermoplastic PBT of UL 94V-0 2-3. Lead Wire : UL3266, 24 awg, GRAY DIMENSIONS Air Flow Direction: Toward label side. UNITSmm SPEC.NO A08000560G-00 REVISION DATE 06. 03. 2013 ISSUE DATE 05. 10. 2005 E D I T I O N 2 SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD PAGE 5 OF 9 D.C.C. 2013.07.15 SUNON Notes .SAFETY 1. DO NOT use or operate this fan in excess of the limitations set forth in this specification. SUNON is not responsible for the non-performance of this fan and/or any damages resulting from its use, if it is not used or operated in accordance with the specifications. 2. SUNON recommends adding a protection circuit to the product or application in which this fan is installed, such as a thermo-fuse, or current-fuse or thermoprotector. The failure to use such a device may result in smoke, fire, electric shock by insulation degradation in cases of motor lock, motor lead short circuit, overload, or over voltage, and/or other failure. 3. SUNON recommends installing a protection device to the product or application in which this fan is installed if there is a possibility of reverseconnection between VDC (+) and GND (-). The failure to install such a device may result in smoke, fire, and/or destruction, although these conditions may not manifest immediately. 4. This fan must be installed and used in compliance with all applicable safety standards and regulations. 5. Use proper care when handling and/or installing this fan. Improper handling or installation of this fan may cause damage that could result in unsafe conditions. 6. Use proper care during installation and/or wiring. Failure to use proper care may cause damage to certain components of the fan including, but not limited to, the coil and lead wires, which could result in smoke and/or fire. 7. DO NOT use power or ground PWM to control the fan speed. If the fan speed needs to be adjusted, please contact SUNON to customize the product design for your application. 8. For critical or extreme environments, including non stop operation, please contact SUNON and we will gladly provide assistance with your product selection to ensure an appropriate cooling product for your application. SPEC.NO A08000560G-00 REVISION DATE 06. 03. 2013 ISSUE DATE 05. 10. 2005 E D I T I O N 2 SUNONWEALTH ELECTRIC D.C.C. MACHINE INDUSTRY CO., LTD. P A G E 6 OF 9 2013.07.15 SUNON Notes II. SPECIFICATION MODIFICATION 1. SUNON offers engineering assistance on fan installation and cooling system design. 2. All changes, modifications and/or revisions to the specifications, if any, are incorporated in the attached specifications. 3. No changes, modifications and/or revisions to these specifications are effective absent agreement, by both SUNON and the customer, in writing. 4. This fan will be shipped in accordance with the attached specification unless SUNON and the customer have agreed otherwise, in writing, as specified in Paragraph 3, above. III. OTHER 1. When building your device, please examine thoroughly any variation of EMC, temperature rise, life data, quality, etc. of this product by shock/drop/vibration testing, etc. If there are any problems or accidents in connection with this product, it should be mutually discussed and examined. 2. Use proper care when handling this fan. Components such as fan holders or bearings may be damaged, if touched with fingers or other objects. Additionally, static electricity (ESD) may damage the internal circuits of the fan. 3. DO NOT operate this fan in proximity to hazardous materials such as organic silicon, cyanogens, formalin, phenol, or corrosive gas environments including, but not limited to, H2S, SO2, NO2, or Cl2. 4. SUNON recommends that you protect this fan from exposure to outside elements such as dust, condensation, humidity or insects. Exposure of this fan to outside elements such as dust, condensation, humidity or insects may affect its performance and may cause safety hazards. SUNON does not warrant against damage to the product caused by outside elements. SPEC.NO A08000560G-00 REVISION DATE 06. 03. 2013 ISSUE DATE 05. 10. 2005 E D I T I O N 2 SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD. P A G E 7 OF 9 D.C.C. 2013.07.15 SUNON Notes 5. This fan must be installed properly and securely. Improper mounting may cause harsh resonance, vibration, and noise. 6. Fan guards may prevent injury during handling or installation of the fan and are available for sale with this fan. 7. Unless otherwise noted, all testing of this fan is conducted at 25C ambient temperature and sixty-five percent (65%) relative humidity. 8. DO NOT store this fan in an environment with high humidity. This fan must be stored in accordance with the attached specifications regarding storage temperature. If this fan is stored for more than 6 months, SUNON recommends functional testing before using. 9. SUNON reserves the right to use components from multiple sources at its discretion. The use of components from other sources will not affect the specifications as described herein. 10. The "Life Expectancy" of this fan has not been evaluated for use in combination with any end application. Therefore, the Life Expectancy Test Reports (L10 and MTTF Report) that relate to this fan are only for reference. VI. WARRANTY This fan is warranted against all defects which are proved to be fault in our workmanship and material for one year from the date of our delivery. The sole responsibility under the warranty shall be limited to the repair of the fan or the replacement thereof, at SUNON's sole discretion. SUNON will not be responsible for the failures of its fans due to improper handing, misuse or the failure to follow specifications or instructions for use. In the event of warranty claim, the customer shall immediately notify SUNON for verification. SUNON will not be responsible for any consequential damage to the customer's equipment as a result of any fans proven to be defective. SPEC.NO A08000560G-00 REVISION DATE 06. 03. 2013 ISSUE DATE 05. 10. 2005 E D I T I O N 2 SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD. P A G E 8 OF 9 D.C.C. 2013.07.15 SUNON Declaration of RoHS Control declaration of environment- related substances/ materials 1. In accordance with the Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, SUNON product have complied with law and discipline not to employ the forbidden substances, and restrict the allowable concentration of some limited substances deliberately in our components. No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Substance CFCs & HCFCs (ozone depleting substances) Chlorinated Organic Solvent Plastic (Frame, Impeller, wire harness, etc.) Solder Lead and its compounds Steel alloy Aluminium alloy Copper alloy Solder Parts composed of metals containing zinc Cadmium and its compounds (e.g. brass, zinc for die casting) Plastic PBBs and PBDEs PCB and PCT CP, Short-chain Chlorinated paraffins C10-13, Cl 48 wt% Mirex PCN Hexavalent Chromium compounds Mercury and its compounds Asbestos Organic Tin compounds Azo compounds TBBP-A in external case plastic parts of products (PCB is exempted) Nickel in external case parts, which are likely to result in prolonged skin exposure Hexabromocyclododecane (HBCDD) Di-butyl Phthalate (DBP) Benzyl butyl Phthalate (BBP) Di-ethylhexyl Phthalate (DEHP) Di-isobutyl Phthalate (DIBP) Criteria Forbidden Forbidden <100ppm <1000ppm <3500ppm <4000ppm <4wt% <20ppm <100ppm <5ppm Forbidden Forbidden Forbidden Forbidden Forbidden <100ppm Forbidden Forbidden Forbidden Forbidden <1000ppm <1000ppm <1000ppm <1000ppm <1000ppm <1000ppm <1000ppm SPEC.NO A08000560G-00 REVISION DATE 06. 03. 2013 ISSUE DATE 05. 10. 2005 E D I T I O N 2 SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD. P A G E 9 OF 9 D.C.C. 2013.07.15