SOLID STATE RELAYS DC SOLID STATE RELAYS TS SERIES 50 TO 250 mA MEETS MIL-R-28750/5,6, & 7 1 7 CONTROL SOURCE LOAD 3 5 DC SUPPLY + + CONTROL SOURCE 1 7 LOAD 3 5 AC OR DC SUPPLY TERMINAL VIEW FEATURES Hermetically sealed TO-5 package Transformer coupled High speed switching TS5-1Y switches AC or DC INPUT CHARACTERISTICS INPUT VOLTAGE RANGE 4.0 - 7.0 Vdc MAXIMUM TURN-ON VOLTAGE 5.0 Vdc MINIMUM TURN-OFF VOLTAGE 1.0 Vdc I/O DIELECTRIC 1000 Vac pk-pk OUTPUT CHARACTERISTICS MAX. OUTPUT CURRENT (CONTINUOUS, 25C) 50 mAac or mAdc (TS5-1Y) 250 mAdc (TS6-1Y) 100 mAdc (TS7-1Y) MAX. OUTPUT VOLTAGE 40 Vac or Vdc (TS5-1Y) 40 Vdc (TS6-1Y) 250 Vdc (TS7-1Y) MAX. ON-RESISTANCE 5 ohms (TS5-1Y) TURN-ON TIME TURN-OFF TIME 10 sec. 15 sec. ENVIRONMENTAL CHARACTERISTICS SHOCK 1500 G's, 0.5 ms. VIBRATION 100 G's, 10 to 2000 Hz OPERATING AMBIENT TEMPERATURE -55 to +125C 46 Tyco Electronics Corporation www.tycoelectronics.com 800-522-6752 (U.S.A.) or 717-564-0100 Specifications subject to change. CII and TYCO are trademarks. (c)2003 by Tyco Electronics Corporation DC SOLID STATE RELAYS 400 3 100 40 30 50 40 7 Vdc INPUT 6 Vdc INPUT -55C 4 Vdc INPUT 90 80 70 60 5 Vdc INPUT RATED CURRENT -125C 5 Vdc INPUT RATED CURRENT 100 90 80 70 60 50 OUTPUT CURRENT (mA) 10 9 8 7 6 5 4 200 -125C -55C OUTPUT CURRENT (mA) 4 Vdc INPUT -125C 5 Vdc INPUT RATED CURRENT 7 Vdc INPUT 6 Vdc INPUT 200 6 Vdc INPUT -55C OUTPUT CURRENT (mA) 300 7 Vdc INPUT 30 20 400 300 4 Vdc INPUT 30 20 20 2 10 1 -60 -40 -20 0 20 40 60 80 100 120 140 10 -60 -40 -20 0 20 40 60 80 100 120 140 AMBIENT TEMPERATURE (C) -60 -40 -20 0 20 40 60 80 100 120 140 AMBIENT TEMPERATURE (C) TS5-1Y TS6-1Y AMBIENT TEMPERATURE (C) TS7-1Y OUTPUT CURRENT VS. INPUT CONTROL VOLTAGE AND AMBIENT TEMPERATURE SOLID STATE RELAYS 100 90 80 70 60 50 40 EW .370 DIA MAX (9.40) .335 DIA MAX (8.51) .275 MAX (12.70) .50 MIN (12.70) .017 DIA (0.43) .031 45 .032 (REF) (0.81) .100 (2.54) .200 (5.08) TS5/TS6/TS7 NOTES: 1) Reversing polarity of input (or output except for TS5-1) may cause permanent damage. 2) Input must be a step function. Rise or fall time, as applicable, not to exceed 100 sec. 3) Inductive loads must be diode suppressed. 4) For any control voltage, the maximum load current shown on graphs must not be exceeded. Attempting to draw currents in excess of those specified on graphs can cause permanent damage. 47 Tyco Electronics Corporation www.tycoelectronics.com 800-522-6752 (U.S.A.) or 717-564-0100 Specifications subject to change. CII and TYCO are trademarks. (c)2003 by Tyco Electronics Corporation