https://www.phoenixcontact.com/us/products/2902993 Power supply unit-UNO-PS/1AC/24DC/100W-2902993 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/100 W Product Description UNO POWER power supplies with basic functionality Thanks to their high power density, compact UNO POWER power supplies are the ideal solution for loads up to 240 W, particularly in compact control boxes. The power supply units are available in various performance classes and overall widths. Their high degree of efficiency and low idling losses ensure a high level of energy efficiency. Your advantages Flexible mounting by simply snapping onto the DIN rail More space in the control cabinet with up to 20 % higher power density Maximum energy efficiency, thanks to over 90 % efficiency and extremely low idling losses under 0.3 W Outdoor installation, thanks to the wide temperature range from -25C to +70C Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356729215 Weight per Piece (excluding packing) 390.000 g Custom tariff number 85044030 Country of origin Vietnam Technical data Dimensions Width 55 mm 03/22/2021Page1/9 https://www.phoenixcontact.com/us/products/2902993 Power supply unit-UNO-PS/1AC/24DC/100W-2902993 Technical data Dimensions Height 90 mm Depth 84 mm Installation distance right/left 0 mm / 0 mm Installation distance top/bottom 30 mm / 30 mm Ambient conditions Degree of protection IP20 Inflammability class in acc. with UL 94 (housing / terminal blocks) V0 Ambient temperature (operation) -25 C ... 70 C (> 55 C Derating: 2.5 %/K) Ambient temperature (start-up type tested) -40 C Ambient temperature (storage/transport) -40 C ... 85 C Max. permissible relative humidity (operation) 95 % (at 25 C, non-condensing) Climatic class 3K3 (in acc. with EN 60721) Degree of pollution 2 Input data Nominal input voltage range 100 VAC ... 240 VAC Input voltage range 85 VAC ... 264 VAC Frequency range (fN) 50 Hz ... 60 Hz 10% Current consumption 2.1 A (100VAC) 0.95 A (240VAC) Nominal power consumption 242.6 VA Inrush current < 40 A (typical) Mains buffering time > 20 ms (120VAC) > 100 ms (230 V AC) Input fuse 4 A (slow-blow, internal) Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K) Power factor (cos phi) 0.47 Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 24 VDC 1% Nominal output current (IN) 4.2 A (-25C...55C) Derating 55 C ... 70 C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series yes Feedback voltage resistance < 35 VDC Protection against overvoltage at the output (OVP) 35 VDC 03/22/2021Page2/9 https://www.phoenixcontact.com/us/products/2902993 Power supply unit-UNO-PS/1AC/24DC/100W-2902993 Technical data Output data Control deviation < 1 % (change in load, static 10 % ... 90 %) < 2 % (Dynamic load change 10 % ... 90 %, 10 Hz) < 0.1 % (change in input voltage 10 %) Residual ripple < 30 mVPP (with nominal values) Output power 100 W Typical response time <1s Maximum power dissipation in no-load condition < 0.5 W Power loss nominal load max. < 11 W General Net weight 0.34 kg Efficiency typ. 88 % (120VAC) typ. 89 % (230 V AC) MTBF (IEC 61709, SN 29500) > 738000 h (40C) Insulation voltage input/output 4 kV AC (type test) 3 kV AC (routine test) Degree of protection IP20 Protection class II (in closed control cabinet) Inflammability class in acc. with UL 94 (housing / terminal blocks) V0 Housing material Polycarbonate Foot latch material POM (Polyoxymethylen) Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions alignable: 0mm horizontally, 30mm vertically Connection data, input Connection method Screw connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 2.5 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 2.5 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 Stripping length 8 mm Screw thread M3 Connection data, output Connection method Screw connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 2.5 mm 03/22/2021Page3/9 https://www.phoenixcontact.com/us/products/2902993 Power supply unit-UNO-PS/1AC/24DC/100W-2902993 Technical data Connection data, output Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 2.5 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 Stripping length 8 mm Screw thread M3 Standards EMC requirements for noise immunity EN61000-6-1 EN61000-6-2 EMC requirements for noise emission EN61000-6-3 EN61000-6-4 Standard - Safety of transformers EN61558-2-16 Standard - Electrical safety IEC62368-1/VDE0805 (SELV) Standard - Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN50178/VDE0160 (PELV) Standard - Safety extra-low voltage IEC62368-1 (SELV) und EN60204-1 (PELV) Standard - Safe isolation DINVDE0100-410 Standard - Limitation of mains harmonic currents EN61000-3-2 Mains variation/undervoltage EN61000-4-11 Conformance/approvals UL approvals UL/C-UL listed UL 508 UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) UL/C-UL Recognized UL 60950-1 CSA CAN/CSA-C22.2 No.60950-1-07 CSA-C22.2 No.107.1-01 CAN/CSA-C22.2 No. 213 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) EMC data Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC Electrostatic discharge EN 61000-4-2 Contact discharge 6 kV (Test Level 3) Discharge in air 8 kV (Test Level 3) Electromagnetic HF field EN61000-4-3 Frequency range 80 MHz ... 1 GHz Test field strength 10 V/m 03/22/2021Page4/9 https://www.phoenixcontact.com/us/products/2902993 Power supply unit-UNO-PS/1AC/24DC/100W-2902993 Technical data EMC data Frequency range 1 GHz ... 2 GHz Test field strength 10 V/m Frequency range 2 GHz ... 3 GHz Test field strength 10 V/m Comments Criterion A Fast transients (burst) EN61000-4-4 Input 4 kV (Test Level 4 - asymmetrical) Output 2 kV (Test Level 3 - asymmetrical) Comments Criterion A Surge voltage load (surge) EN61000-4-5 Input 2 kV (Test Level 3 - symmetrical) 4 kV (Test Level 4 - asymmetrical) Output 1 kV (Test Level 2 - symmetrical) 2 kV (Test Level 1 - asymmetrical) Comments Criterion B Conducted interference EN61000-4-6 Frequency range 150 kHz ... 80 MHz Voltage 10 V (Test Level 3) Comments Criterion A Voltage dips EN61000-4-11 Criterion A Normal operating behavior within the specified limits. Criterion B Temporary impairment to operational behavior that is corrected by the device itself. Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 25; For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Block diagram L N + + - - 03/22/2021Page5/9 https://www.phoenixcontact.com/us/products/2902993 Power supply unit-UNO-PS/1AC/24DC/100W-2902993 Classifications eCl@ss eCl@ss 10.0.1 27040701 eCl@ss 11.0 27040701 eCl@ss 4.0 27040700 eCl@ss 4.1 27040700 eCl@ss 5.0 27049000 eCl@ss 5.1 27049000 eCl@ss 6.0 27049000 eCl@ss 7.0 27049002 eCl@ss 9.0 27040701 ETIM ETIM 3.0 EC001039 ETIM 4.0 EC000599 ETIM 6.0 EC002540 ETIM 7.0 EC002540 UNSPSC UNSPSC 6.01 30211502 UNSPSC 7.0901 39121004 UNSPSC 11 39121004 UNSPSC 12.01 39121004 UNSPSC 13.2 39121004 UNSPSC 18.0 39121004 UNSPSC 19.0 39121004 UNSPSC 20.0 39121004 UNSPSC 21.0 39121004 Approvals Approvals Approvals UL Listed / UL Recognized / cUL Recognized / IECEE CB Scheme / cUL Listed / EAC / EAC / cULus Recognized / cULus Listed Ex Approvals UL Listed / cUL Listed / cULus Listed 03/22/2021Page6/9 https://www.phoenixcontact.com/us/products/2902993 Power supply unit-UNO-PS/1AC/24DC/100W-2902993 Approvals Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 214596 cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 214596 IECEE CB Scheme http://www.iecee.org/ DK-39228-A1-UL cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 EAC EAC-Zulassung EAC RU*DE*08.B.01873/19 cULus Recognized cULus Listed 03/22/2021Page7/9 https://www.phoenixcontact.com/us/products/2902993 Power supply unit-UNO-PS/1AC/24DC/100W-2902993 Accessories Accessories Device circuit breakers Electronic circuit breaker-CBMC E4 24DC/1-4A NO-2906031 Multi-channel electronic circuit breaker for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails. Electronic circuit breaker-CBMC E4 24DC/1-10A NO-2906032 Multi-channel electronic circuit breaker for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails. Device protection Type 3 surge protection device-PLT-SEC-T3-230-FM-UT-2907919 Type2/3 surge protection, consisting of protective plug and base element with screw connection. For single-phase power supply network with integrated status indicator and remote signaling. Nominal voltage: 230VAC/DC Type 3 surge protection device-PLT-SEC-T3-24-FM-UT-2907916 Type3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote signaling for single-phase power supply networks. Nominal voltage: 24VAC/DC Redundancy module 03/22/2021Page8/9 https://www.phoenixcontact.com/us/products/2902993 Power supply unit-UNO-PS/1AC/24DC/100W-2902993 Accessories Redundancy module-UNO-DIODE/5-24DC/2X10/1X20-2905489 Redundancy module, 5 V - 24 V DC, 2 x 10 A, 1 x 20 A. Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 03/22/2021Page9/9