Film Capacitors Metallized Polypropylene Film Capacitors (MKP) Series/Type: B32669 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product see following page Date of Withdrawal 2014-04-11 Deadline Last Orders 2014-07-15 Last Shipments 2014-10-15 For further information please contact your nearest EPCOS sales office, which will also support you in selecting a suitable substitute. The addresses of our worldwide sales network are presented at www.epcos.com/sales. EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company. Affected products (Ordering code) B32669B6105J000 B32669B6105K000 B32669B6155J000 B32669B6155K000 B32669B6205K000 B32669B6255K000 B32669B6305J150 B32669B6305K000 B32669B6405K000 B32669B6505K000 B32669B6605K000 B32669C1156K000 B32669C3106J000 B32669C3205J000 B32669C3205K000 B32669C3225K000 B32669C3255J000 B32669C3255K000 B32669C3305K000 B32669C3405K000 B32669C3605K000 B32669C3805K000 B32669S1104K500 B32669S3105K500 B32669S3105K501 B32669S3106K500 B32669S3126K550 B32669S3156K550 B32669S3225K500 B32669S3405K506 B32669S3505K550 B32669S3564K600 B32669S3605K500 B32669S3684K500 B32669S3684K600 Metallized polypropylene film capacitors (MKP) B32669 AC applications (wound) Not suitable for "across the line" applications! Dimensional drawing Typical applications Energy storage Filtering Climatic Max. operating temperature: 85 C Climatic category (IEC 60068-1): 40/085/21 Construction Dielectric: polypropylene (PP) Cylindrical winding Insulating sleeve Face ends sealed with epoxy resin Features Good self-healing properties RoHS-compatible Terminals Axial leads, lead-free tinned Axial leads, insulated, tinned copper wires gathered together by a tin cover (fray), AWG 22 Dimensions in mm When bending leads, take care to leave a clearance of 1 mm to the capacitor body. Marking Manufacturer Series number rated capacitance (coded), capacitance tolerance (code letter), rated AC voltage, frequency, date code Delivery mode Bulk (untaped) Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 15 B32669 AC applications (wound) Overview of available types Version Tinned leads Page 4 VRMS (V AC) 250 Insulated leads 5 400 250 CR (F) 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0 8.0 10 Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 15 400 B32669 AC applications (wound) Ordering codes and packing units (tinned leads) VRMS CR V AC 250 F 1.0 1.5 2.0 2.5 3.0 4.0 6.0 8.0 10 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0 400 Max. dimensions dxl mm 9.0 x 32.0 11.0 x 32.0 12.5 x 32.0 14.0 x 32.0 15.5 x 32.0 15.0 x 47.0 17.0 x 47.0 19.5 x 47.0 21.5 x 47.0 13.0 x 32.0 15.0 x 32.0 19.0 x 32.0 21.0 x 32.0 18.0 x 47.0 21.0 x 47.0 22.0 x 47.0 25.5 x 47.0 Ordering code (composition see below) B32669C3105+000 B32669C3155+000 B32669C3205+000 B32669C3255+000 B32669C3305+000 B32669C3405+000 B32669C3605+000 B32669C3805+000 B32669C3106+000 B32669B6105+000 B32669B6155+000 B32669B6205+000 B32669B6255+000 B32669B6305+000 B32669B6405+000 B32669B6505+000 B32669B6605+000 Untaped pcs./MOQ 1000 1000 800 800 600 600 400 200 200 1000 800 800 600 600 400 600 200 MOQ = Minimum Order Quantity, consisting of 4 packing units. Further E series and intermediate capacitance values on request. Composition of ordering code + = Capacitance tolerance code: K = 10% J = 5% Please read Cautions and warnings and Important notes at the end of this document. Page 4 of 15 B32669 AC applications (wound) Ordering codes and packing units (insulated leads) VRMS CR V AC 250 F 1.0 1.5 2.0 2.5 3.0 4.0 6.0 8.0 10 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0 400 Max. dimensions dxl mm 9.0 x 32.0 11.0 x 32.0 12.5 x 32.0 14.0 x 32.0 15.5 x 32.0 15.0 x 47.0 17.0 x 47.0 19.5 x 47.0 21.5 x 47.0 13.0 x 32.0 15.0 x 32.0 19.0 x 32.0 21.0 x 32.0 18.0 x 47.0 21.0 x 47.0 22.0 x 47.0 25.5 x 47.0 Ordering code (composition see below) B32669S3105+*** B32669S3155+*** B32669S3205+*** B32669S3255+*** B32669S3305+*** B32669S3405+*** B32669S3605+*** B32669S3805+*** B32669S3106+*** B32669S6105+*** B32669S6155+*** B32669S6205+*** B32669S6255+*** B32669S6305+*** B32669S6405+*** B32669S6505+*** B32669S6605+*** Untaped pcs./MOQ 1000 1000 1000 1000 800 800 600 600 600 1000 1000 1000 600 600 600 600 600 MOQ = Minimum Order Quantity, consisting of 4 packing units. Further E series and intermediate capacitance values on request. Composition of ordering code + = Capacitance tolerance code: K = 10% J = 5% Please read Cautions and warnings and Important notes at the end of this document. *** = Code number for lead version and length: 504 = Insulated leads (lead length 160 mm) 508 = Insulated leads (lead length 65 mm) Page 5 of 15 B32669 AC applications (wound) Technical data Operating temperature range Dissipation factor tan at 20 C (upper limit values) Time constant = CR Rins at 20 C, rel. humidity 65% (minimum as-delivered values) DC test voltage AC test voltage Damp heat test Limit values after damp heat test Max. operating temperature Top,max Upper category temperature Tmax Lower category temperature Tmin Rated temperature TR 2 10-3 at 1 kHz 2500 s VR = 250 V AC: 430 V DC, 1 s VR = 400 V AC: 700 V DC, 1 s VR = 250 V AC: 440 V AC, 1 s VR = 400 V AC: 700 V AC, 1 s 21 days/40 C/93% relative humidity Capacitance change C/C Dissipation factor change tan Time constant = CR Rins Pulse handling capability (rate of voltage rise Vpp/) +85 C +85 C 40 C +85 C 3% 0.5 10-3 (at 1 kHz) 1.0 10-3 (at 10 kHz) 50% of minimum as-delivered values 10 V/s Permissible AC voltage VRMS versus frequency f Values can be obtained on request. In specific cases please provide a scaled voltage/ time graph and state operating conditions. Please read Cautions and warnings and Important notes at the end of this document. Page 6 of 15 B32669 AC applications (wound) Mounting guidelines 1 Soldering 1.1 Solderability of leads The solderability of terminal leads is tested to IEC 60068-2-20, test Ta, method 1. Before a solderability test is carried out, terminals are subjected to accelerated ageing (to IEC 60068-2-2, test Ba: 4 h exposure to dry heat at 155 C). Since the ageing temperature is far higher than the upper category temperature of the capacitors, the terminal wires should be cut off from the capacitor before the ageing procedure to prevent the solderability being impaired by the products of any capacitor decomposition that might occur. Solder bath temperature 235 5 C Soldering time 2.0 0.5 s Immersion depth 2.0 +0/0.5 mm from capacitor body or seating plane Evaluation criteria: Visual inspection Wetting of wire surface by new solder 90%, free-flowing solder 1.2 Resistance to soldering heat Resistance to soldering heat is tested to IEC 60068-2-20, test Tb, method 1A. Conditions: Series Solder bath temperature Soldering time MKT boxed (except 2.5 x 6.5 x 7.2 mm) 260 5 C coated uncoated (lead spacing > 10 mm) MFP MKP (lead spacing > 7.5 mm) MKT boxed (case 2.5 x 6.5 x 7.2 mm) MKP (lead spacing 7.5 mm) MKT uncoated (lead spacing 10 mm) insulated (B32559) Please read Cautions and warnings and Important notes at the end of this document. Page 7 of 15 10 1 s 5 1 s <4s recommended soldering profile for MKT uncoated (lead spacing 10 mm) and insulated (B32559) B32669 AC applications (wound) Immersion depth 2.0 +0/0.5 mm from capacitor body or seating plane Shield Heat-absorbing board, (1.5 0.5) mm thick, between capacitor body and liquid solder Evaluation criteria: Visual inspection C/C0 tan Please read Cautions and warnings and Important notes at the end of this document. No visible damage 2% for MKT/MKP/MFP 5% for EMI suppression capacitors As specified in sectional specification Page 8 of 15 B32669 AC applications (wound) 1.3 General notes on soldering Permissible heat exposure loads on film capacitors are primarily characterized by the upper category temperature Tmax. Long exposure to temperatures above this type-related temperature limit can lead to changes in the plastic dielectric and thus change irreversibly a capacitor's electrical characteristics. For short exposures (as in practical soldering processes) the heat load (and thus the possible effects on a capacitor) will also depend on other factors like: Pre-heating temperature and time Forced cooling immediately after soldering Terminal characteristics: diameter, length, thermal resistance, special configurations (e.g. crimping) Height of capacitor above solder bath Shadowing by neighboring components Additional heating due to heat dissipation by neighboring components Use of solder-resist coatings The overheating associated with some of these factors can usually be reduced by suitable countermeasures. For example, if a pre-heating step cannot be avoided, an additional or reinforced cooling process may possibly have to be included. EPCOS recommends the following conditions: Pre-heating with a maximum temperature of 110 C Temperature inside the capacitor should not exceed the following limits: MKP/MFP 110 C MKT 160 C When SMD components are used together with leaded ones, the leaded film capacitors should not pass into the SMD adhesive curing oven. The leaded components should be assembled after the SMD curing step. Leaded film capacitors are not suitable for reflow soldering. Uncoated capacitors For uncoated MKT capacitors with lead spacings 10 mm (B32560/B32561) the following measures are recommended: pre-heating to not more than 110 C in the preheater phase rapid cooling after soldering Please read Cautions and warnings and Important notes at the end of this document. Page 9 of 15 B32669 AC applications (wound) Cautions and warnings Do not exceed the upper category temperature (UCT). Do not apply any mechanical stress to the capacitor terminals. Avoid any compressive, tensile or flexural stress. Do not move the capacitor after it has been soldered to the PC board. Do not pick up the PC board by the soldered capacitor. Do not place the capacitor on a PC board whose PTH hole spacing differs from the specified lead spacing. Do not exceed the specified time or temperature limits during soldering. Avoid external energy inputs, such as fire or electricity. Avoid overload of the capacitors. The table below summarizes the safety instructions that must always be observed. A detailed description can be found in the relevant sections of the chapters "General technical information" and "Mounting guidelines". Topic Storage conditions Flammability Resistance to vibration Safety information Reference chapter "General technical information" Make sure that capacitors are stored within the 4.5 specified range of time, temperature and humidity "Storage conditions" conditions. Avoid external energy, such as fire or electricity 5.3 (passive flammability), avoid overload of the "Flammability" capacitors (active flammability) and consider the flammability of materials. Do not exceed the tested ability to withstand 5.2 vibration. The capacitors are tested to "Resistance to vibration" IEC 60068-2-6. EPCOS offers film capacitors specially designed for operation under more severe vibration regimes such as those found in automotive applications. Consult our catalog "Film Capacitors for Automotive Electronics". Please read Cautions and warnings and Important notes at the end of this document. Page 10 of 15 B32669 AC applications (wound) Topic Safety information Soldering Do not exceed the specified time or temperature limits during soldering. Cleaning Use only suitable solvents for cleaning capacitors. Embedding of When embedding finished circuit assemblies in capacitors in plastic resins, chemical and thermal influences finished assemblies must be taken into account. Caution: Consult us first, if you also wish to embed other uncoated component types! Please read Cautions and warnings and Important notes at the end of this document. Page 11 of 15 Reference chapter "Mounting guidelines" 1 "Soldering" 2 "Cleaning" 3 "Embedding of capacitors in finished assemblies" B32669 AC applications (wound) Symbols and terms Symbol C A C C CR C C/C C/CR dt t T tan V dV/dt V/t E ESL ESR f f1 f2 fr FD FT i IC English Heat transfer coefficient Temperature coefficient of capacitance Capacitor surface area Humidity coefficient of capacitance Capacitance Rated capacitance Absolute capacitance change Relative capacitance change (relative deviation of actual value) Capacitance tolerance (relative deviation from rated capacitance) Time differential Time interval Absolute temperature change (self-heating) Absolute change of dissipation factor Absolute voltage change Time differential of voltage function (rate of voltage rise) Voltage change per time interval Activation energy for diffusion Self-inductance Equivalent series resistance Frequency Frequency limit for reducing permissible AC voltage due to thermal limits German Warmeubergangszahl Temperaturkoeffizient der Kapazitat Kondensatoroberflache Feuchtekoeffizient der Kapazitat Kapazitat Nennkapazitat Absolute Kapazitatsanderung Relative Kapazitatsanderung (relative Abweichung vom Ist-Wert) Kapazitatstoleranz (relative Abweichung vom Nennwert) Differentielle Zeit Zeitintervall Absolute Temperaturanderung (Selbsterwarmung) Absolute Anderung des Verlustfaktors Absolute Spannungsanderung Differentielle Spannungsanderung (Spannungsflankensteilheit) Spannungsanderung pro Zeitintervall Aktivierungsenergie zur Diffusion Eigeninduktivitat Ersatz-Serienwiderstand Frequenz Grenzfrequenz fur thermisch bedingte Reduzierung der zulassigen Wechselspannung Frequency limit for reducing permissible Grenzfrequenz fur strombedingte AC voltage due to current limit Reduzierung der zulassigen Wechselspannung Resonant frequency Resonanzfrequenz Thermal acceleration factor for diffusion Therm. Beschleunigungsfaktor zur Diffusion Derating factor Deratingfaktor Current (peak) Stromspitze Category current (max. continuous Kategoriestrom (max. Dauerstrom) current) Please read Cautions and warnings and Important notes at the end of this document. Page 12 of 15 B32669 AC applications (wound) Symbol IRMS iz k0 LS 0 test Pdiss Pgen Q R R Ri Rins RP RS S t T tan tan D tan P tan S TA Tmax Tmin tOL Top TR Tref tSL VAC English (Sinusoidal) alternating current, root-mean-square value Capacitance drift Pulse characteristic Series inductance Failure rate Constant failure rate during useful service life Failure rate, determined by tests Dissipated power Generated power Heat energy Density of water vapor in air Universal molar constant for gases Ohmic resistance of discharge circuit Internal resistance Insulation resistance Parallel resistance Series resistance severity (humidity test) Time Temperature Time constant Dissipation factor Dielectric component of dissipation factor Parallel component of dissipation factor Series component of dissipation factor Ambient temperature Upper category temperature Lower category temperature Operating life at operating temperature and voltage Operating temperature Rated temperature Reference temperature Reference service life AC voltage Please read Cautions and warnings and Important notes at the end of this document. German (Sinusformiger) Wechselstrom Inkonstanz der Kapazitat Impulskennwert Serieninduktivitat Ausfallrate Konstante Ausfallrate in der Nutzungsphase Experimentell ermittelte Ausfallrate Abgegebene Verlustleistung Erzeugte Verlustleistung Warmeenergie Dichte von Wasserdampf in Luft Allg. Molarkonstante fur Gas Ohmscher Widerstand des Entladekreises Innenwiderstand Isolationswiderstand Parallelwiderstand Serienwiderstand Scharfegrad (Feuchtetest) Zeit Temperatur Zeitkonstante Verlustfaktor Dielektrischer Anteil des Verlustfaktors Parallelanteil des Verlfustfaktors Serienanteil des Verlustfaktors Umgebungstemperatur Obere Kategorietemperatur Untere Kategorietemperatur Betriebszeit bei Betriebstemperatur und -spannung Beriebstemperatur Nenntemperatur Referenztemperatur Referenz-Lebensdauer Wechselspannung Page 13 of 15 B32669 AC applications (wound) Symbol VC VC,RMS English Category voltage Category AC voltage VCD Vch VDC VFB Vi Vo Vop Vp Vpp VR Corona-discharge onset voltage Charging voltage DC voltage Fly-back capacitor voltage Input voltage Output voltage Operating voltage Peak pulse voltage Peak-to-peak voltage Impedance Rated voltage Amplitude of rated AC voltage R VRMS German Kategoriespannung (Sinusformige) Kategorie-Wechselspannung Teilentlade-Einsatzspannung Ladespannung Gleichspannung Spannung (Flyback) Eingangsspannung Ausgangssspannung Betriebsspannung Impuls-Spitzenspannung Spannungshub Nennspannung Amplitude der Nenn-Wechselspannung VSC Vsn (Sinusoidal) alternating voltage, root-mean-square value S-correction voltage Snubber capacitor voltage Z Impedance Spannung bei Anwendung "S-correction" Spannung bei Anwendung "Beschaltung" Scheinwiderstand Lead spacing Rasterma Please read Cautions and warnings and Important notes at the end of this document. (Sinusformige) Wechselspannung Page 14 of 15 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CeraLink, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, FilterCap, FormFit, MiniBlue, MiniCell, MKD, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 15 of 15