SCHRACK General Purpose Relays Power Relay RF n 1 pole 16 A, 1 NO or 1 NC contact n Switching capacity 4000 VA n Coil power 400 mW n Reinforced insulation (EN 61810, 60335, 60730) n Ambient temperature up to 105C n Quick connect terminals for load side n WG version: Materials in accordance to IEC 60335-1 Applications Oven control, electric heating, power supplies, air conditioning, microwares, hobs F0273-BI Approvals V REG.-Nr. A652, Z E214025 Technical data of approved types on request Contact data Contact configuration Contact set Type of interruption Rated voltage / max. switching voltage AC Rated current Maximum breaking capacity AC Limiting making capacity, max 4 s, duty factor 10% Contact material Minimum contact load Rated frequency of operation with / without load Operate- / release time Bounce time NO / NC contact Contact ratings Type Contact Load IEC 61810 RF334; RFH34 RF334; RFH34 RF334; RFH34 RF334; RFH34 RF354; RFH54 RF354; RFH54 RF354; RFH54 RFH34 RFH34 RFH34 RFH34 16 A, 250 VAC, cos=1 11 A, 250 VAC, cos=1 20 A, 250 VAC, cos=1 25 A, 250 VAC, cos=1 16 A, 250 VAC, cos=1 20 A, 250 VAC, cos=1 25 A, 250 VAC, cos=1 16 A, 250 VAC, cos=1 11 A, 250 VAC, cos=1 18.5 A, 250 VAC, cos=1 10 A, 400 VAC, cos=1 NO NO NO NO NC NC NC NO NO NO NO 1NO or 1NC single contact micro disconnection 250 / 400 VAC 16 A 4000 VA 25 A AgNi90/10 12VAC / 500mA 6 / 1200 min-1 max. 11 / 7 ms max. 4 / 4 ms Ambient temp. [C] Cycles 85C 85C 85C 70C 85C 85C 70C 105C 105C 105C 105C 100x103 250x103 25x103 15x103 100x103 50x103 20x103 100x103 250x103 20x103 150x103 Coil data Rated coil voltage DC coil Operative range to IEC 61810 Coil insulation system according UL1446 5...60 VDC 2 Class F 1 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the `Schrack' section. Specifications subject to change. SCHRACK General Purpose Relays Power Relay RF (Continued) Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ohm mW 005 5 3.5 0.5 62+10% 403 006 6 4.2 0.6 90+10% 400 009 9 6.3 0.9 203+10% 399 012 12 8.4 1.2 360+10% 400 024 24 16.8 2.4 1440+10% 400 048 48 33.6 4.8 5520+10% 417 060 60 42.0 6.0 8570+10% 420 All figures are given for coil without preenergization, at ambient temperature +23C Other coil voltages on request Insulation Dielectric strength coil-contact circuit open contact circuit Clearance / creepage coil-contact circuit Material group of insulation parts Tracking index of relay base Insulation to IEC 60664-1 Type of insulation coil-contact circuit open contact circuit Rated insulation voltage Pollution degree Rated voltage system Overvoltage category 4000 Vrms 1000 Vrms W 8 / 8 mm W IIIa PTI 250 PCB layout / terminal assignment Bottom view on solder pins reinforced micro disconnection 250 V 3 230 / 400 V III S0256-CA Other data Mechanical endurance 10x106 cycles Material RoHS - Directive 2002/95/EC compliant Resistance to heat and fire, WG version according EN60335-1, par.30 Environment Ambient temperature range -40...+105C Vibration resistance (function) NO / NC cont. (55...500Hz) 20 / 5 ms Shock resistance (destruction) 100 g Category of protection RTII - flux proof; RTIII - wash tight Processing Mounting pcb Resistance to soldering heat flux-proof version 270C / 10 s wash-tight version 260C / 5 s Relay weight 20 g Packaging unit 150 / 300 pcs 1 NO contact S0256-CB 1 NC contact S0256-CC Dimensions Quick connect terminals vertical Quick connect terminals horizontal S0282-CI S0282-CJ 2 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the `Schrack' section. Specifications subject to change. SCHRACK General Purpose Relays Power Relay RF (Continued) Product key Typical product key RF 3 3 4 012 WG Type RF Power Relay RF Version 3 16 A, 85C H 16 A, 105C Contact configuration 3 1 NO contact (1 form A), quick connect term. vertical 5 1 NC contact (1 form B), quick connect term. vertical D 1 NO contact (1 form A), quick connect term. horizontal F 1 NC contact (1 form B), quick connect term. horizontal Contact material 4 AgNi 90/10 Coil Coil code: please refer to coil versions table Version Blank Standard version WG Product in accordance with IEC 60335-1 (domestic appliances) Wash tight version on request Product key RF334006 RF334009 RF334012 RF334024 RF354006 RF354009 RF354012 RF354024 RFH34006 RFH34009 RFH34012 RFH34024 RFH54006 RFH54009 RFH54012 RFH54024 RF334006WG RF334009WG RF334012WG RF334024WG RF354006WG RF354012WG RF354024WG RF354048WG RFH34006WG RFH34009WG RFH34012WG RFH34024WG RFH54006WG RFH54009WG RFH54012WG RFH54024WG Version 16 A 85C Configuration 1 NO contact quick connect term. vertical Cont. material AgNi 90/10 1 NC contact quick connect term. vertical 16 A 105C 1 NO contact quick connect term. vertical 1 NC contact quick connect term. vertical 16 A 85C materials according IEC 60335-1 1 NO contact quick connect term. vertical 1 NC contact quick connect term. vertical 16 A 105C materials according IEC 60335-1 1 NO contact quick connect term. vertical 1 NC contact quick connect term. vertical Coil 6 VDC 9 VDC 12 VDC 24 VDC 6 VDC 9 VDC 12 VDC 24 VDC 6 VDC 9 VDC 12 VDC 24 VDC 6 VDC 9 VDC 12 VDC 24 VDC 6 VDC 9 VDC 12 VDC 24 VDC 6 VDC 9 VDC 12 VDC 24 VDC 6 VDC 9 VDC 12 VDC 24 VDC 6 VDC 9 VDC 12 VDC 24 VDC Part number 5-1415513-1 7-1415513-1 8-1415513-1 9-1415513-1 2-1415514-1 3-1415514-1 4-1415514-1 5-1415514-1 8-1415510-1 9-1415510-1 6-1415510-1 1415511-1 4-1415511-1 5-1415511-1 6-1415511-1 7-1415511-1 5-1415517-1 6-1415517-1 7-1415517-1 8-1415517-1 2-1415518-1 4-1415518-1 5-1415518-1 6-1415518-1 3-1415520-1 4-1415520-1 5-1415520-1 6-1415520-1 1415521-1 1-1415521-1 2-1415521-1 3-1415521-1 3 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the `Schrack' section. Specifications subject to change.