219 Series - Industrial Relays DPDT, up to 6PST, 10 Amps Al Versatile. Rugged. Proven. These are but a few words used by customers to describe the 219 series. File No, 13224 When long life and cost of down time / service are important the 219 solves the problem. Its a of up to four poles double throw or six poles single throw. Contact arrangements are easily @ standard throughout industrial applications which many other relays are measured against. Capable customized for special applications. NUCLEAR versions are available that utilize special platings and materials to minimize wear. All 219s are built with materials that meet the UL 94-VO requirements. GENERAL SPECIFICATIONS (@ 25 C) Contacts: Contact Configuration Contact Material Contact Rating 120 / 240VAC Resistive 28VDC Resistive Contact Resistance, Initial Coil: Coils Available Nominal Coil Power Input Voltage Tolerance - AC Input Voltage Tolerance - DC Drop-out voltge Duty Timing: Operate Time (max) Release Time (max) Dielectric Strength: Across Open Contacts Between mutually insulated point Insulation resistance Temperature: Operating Storage Life Expectancy: Electrical (full load) Mechanical (no load) Miscellaneous: Mounting Position Enclosure Weight (Approximately) Mating socket (UL Listed when used) Up to 4PDT or 6PST Silver Alloy-Gold Diffused 10 Amp / 5 Amp 10 Amp 50 milliohms max @ 6vde AC and DC AC 5VA DC 1.8-2.5W 85% to 110% of nominal 80% to 110% of nominal 10% of nominal Continuous 25mS 20mS 500Vrms 1500Vrms 1,000 Mohms min @ 500VDC AC = -20 to 60C (-4 to 140F) DC = -20 to 70C (-4 to 158F) -40 to 105C (-40 to 221F) 100,000 10,000,000 Any Clear Polycarbonate 8.50z (241 grams) 12 PIN: 27390 (D) 14 PIN: 33377 (D) (D) is option for DIN Rail Mount www.struthers-dunn.com (843) 346-4427 Optional Manual Actuator August 2017Ordering Code 219. Series 219 Contact Arrangement XBX (DPDT) ABA (1 Pole N.O. + DPDT + 1 Pole N.C.) BBX (2 Pole NO & DPDT) XDX (4PDT) FXX (6 Pole-NO) DXB (4 Pole - NO & 2 Pole-NC) *See our website configurator for more contact configurations Optional Features |< Is Permanent Magnet Blowout - CODE 69 Polycarbonate Cover - CODE P Indicator Lamp - CODE L Manual Actuator - CODE M Bifurcated Contacts - CODE 33 Coil Suppression Diode - CODE V Coil Voltage AC: 12, 24, 120, 240, (Add VAC) DC: 6, 12, 24/28, 32, 48, 115/125, 250 (Add VDC) *Coil voltages and frequencies must be specified August 2017 UL Contact Load Ratings Contact Load Load Configuration Smrennilr Voltage | Frequency ea 10 Amp 120 VAC 50/60Hz Resistive 5 Amp 240 VAC 50/60Hz Resistive ee 10Amp | 28VDC pc Resistive Code 33 0.5 Amp 125 VDC DC Resistive 1/6HP 120 VAC 50/60Hz Motor 1/3HP 240 VAC 50/60Hz Motor Code 33 5 Amp 120 VAC 50/60HzZ General Purpose 2.5 Amp 240 VAC 50/60Hz General Purpose Additional UL Contact Ratings for Code 69 relays incorporating a blowout magnet. Contact Load Load Configuration Career Voltage | Frequency Tape er heed All Styles 3 Amp 125 VDC DC Resistive EXCEPT Code 33 1 Amp 250 VDC DC Resistive See the next page for additional Contact Ratings Use Code 33 for bifurcated contacts when switching low level current below 50mA. 219 Coil Specifications DC Coils AC Coils, 50/60HZ Nominal, Resistance | Milliamperes voltage | ohms Cold +10% 6 14 1500 12 4.2 750 24 15.5 375 120 540 75 240 2100 32 Hot 840 410 200 40 17 Impedance , Nominal ohms t.2 27 120 2,700 13,400 voltage 6 12 24 /28* 32 37.5 48 115/125* 250 Resistance ohms +10% 15.5 63.5 250 375 375 975 6200 27777 Milliamperes Cold Hot 385 304 189 147 96 77 86 62 100 80 49 39 20 16 9 7 Note: Stock 24VDC and 115VDC relays have nameplates stamped 24/28VDC and 115/125VDC respectively. These relays operate at 80% of the lower voltages and operate within allowable temperature rises at higher voltages. www.struthers-dunn.com (843) 346-4427General Purpose Relays Additional Contact Ratings Highest Load for Standard Contacts *Current - A, Resistive unless otherwise noted Voltage Current, A Switching Type 28 VDC, 69 10A Make & Break 48 VDC, 69 10A Make & Carry 5A Make & Break 10A Make & Carry 125 VDC, 69 4A Carry & Break 3A Make & Break 4A Make & Carry 250 VDC, 69 2A Carry & Break 1A Make & Break 120 VAC 10A, 3A Inductive, 1/6 HP Make & Break 240 VAC 10A, 1/3 HP Make & Break 10A Make & Carry 277 VAC 7A Carry & Break 4.5A Make & Break Lowest Load for Standard Contacts *Current - A, Resistive unless otherwise noted Voltage Current, A Switching Type 5 VDC 1A Make & Break 12 VDC 0.75A Make & Break 28 VDC 0.050A Make & Break 48 VDC 0.050A Make & Break 125VDC 0,050A Make & Break 250 VDC 0.050A Make & Break 120 VAC 0.050A Make & Break 240 VAC 0.050A Make & Break 480 VAC 0.050A Make & Break Highest Load for Bifurcated Contacts *Current - A, Resistive unless otherwise noted Vv 125VDC 250 VDC 120 VAC 240 VAC 277 VAC 480 VAC A 5A 3A 2.5 3A 2A 1A 0.5 Make & Carry & Break Make & Break Make & Ca Carry & Break Make & Break Make & Carry & Break Make & Break Make & Ca Carry & Break Make & Break Make & Carry & Break Make & Break Make & Ca Carry & Break Make & Break Make & Carry & Break Make & Break Make & Ca Make & Break Lowest Load for Bifurcated Contacts *Current - A, Resistive unless otherwise noted Use Code 69 for blowout magnet when switching voltages above 40VDC. Use Code 33 for bifurcated contacts when switching low level current below 50mA. Voltage Current, A Switching Type 5 VDC 0.14 Make & Break 12 VDC 0.075A Make & Break 28 VDC 0.01A Make & Break 48 VDC 0.005A Make & Break 125VDC 0.005A Make & Break 250 VDC 0.001A Make & Break 120 VAC 0.01A Make & Break 240 VAC 0.0054 Make & Break 480 VAC 0.001A Make & Break www.struthers-dunn.com (843) 346-4427 August 2017219 Series - Industrial Relays DPDT, Up To 6PST, 10 Amps Outline Dimensions Dimensions Shown in inches & (millimeters) 12 Pin Plug-in 14 Pin Plug-in Optional manual actuator = g 95 Optional manual actuator 9 25 \ 2.52 (6.3) \ 301 (6.3) my (64.1) = (76.4) " Locking clip Locking clip 1.45 (36.8) 1.45 (36.8) 10 x .43 (2.5 x 11.0) DIA. Typical 10 x .43 (2.5 x 11.0) DIA. Typical 1 tira 4 of all pin dimensions of all pin dimensions A August 2017 www.struthers-dunn.com (843) 346-4427219 Wire Diagram (Top View) 12-Pin 219ABX 219ABA 219BBX 219BXB (SPST-N.O. + DPDT) (DPDT+SP-NO+1P-NC ) (DPDT+2P- N.O.) (DPDT+2P- N.O.) 65 43 2 1 .. 432. 1 65) 4 ay ai ut tt bytes + tit td fh oath rh sili ch e 7 8 10 11 12 10 11 12 7 8 9 10 11 12 Many additional contact combinations and 219XBX 2149XCX wiring schematics are available. Contact sales (DPDT) (3PDT) with requirements. Standard Diode Suppression Wiring (applies to relays with option V", alternative polarity/wiring is also available as a special) (12-Pin) +6 4@ 7- 219 Wire Diagram (14-Pin) (Top View) 14-Pin +7 \ 8- 219BXD 219CXC 219DXB 219EXA (2P-NO+4P-NC) (3P-NO+3P-NC) (4P-NO+2P-NC) (5P-NO+1P-NC) | | 3 er vo ue tH oy 8 9 10 ie : 13 14 219F XX 219XJX ISE-NO) (3PST-DM) (4PDT) (DPDT-DM/DB) | file. gl 8 - 10 11 iv 13 14 UL LISTED when used with mating sockets 27390 for 12 pin or 33377 for 14 pin www.struthers-dunn.com (843) 346-4427 August 2017