8-2 Endurance
Item Specification and Requirement Test Method
Thermal Shock Inductance change : Within ± 5%
Without distinct damage in
appearance
(1) Repeat 100 cycle as follow :
(-55 ± 2℃,30 ± 3minutes)
→(Room temperature, 5 minutes)
→(+125 ± 2℃,30 ± 3minutes)
→(Room temperature, 5 minutes)
(2) Recovery : 48 + 4 / - 0 hours of
recovery under the standard
condition after the test.
( See Note1 )
High Temperature
resistance
Inductance change : Within ± 5%
Without distinct damage in
appearance
(1) Environment condition :85 ± 2℃
Applied Current : Rated current
(2) Duration : 1,000 + 4 / - 0 hours
( See Note1 )
Humidity
resistance
Inductance change : Within ± 5%
Without distinct damage in
appearance
(1) Environment condition :60 ± 2℃
Humidity :90~95﹪
Applied Current : Rated current
(2) Duration : 1,000 + 4 / - 0 hours
( See Note1 )
Low Temperature
Store
Inductance change : Within ± 5%
Without distinct damage in
appearance
(1) Store temperature :
-55 ± 2℃ for total
1,000 + 4 / - 0 hours
High
Temperature Store
Inductance change : Within ± 5%
Without distinct damage in
appearance
(1) Store temperature :
+125 ± 2℃ for total
1,000 + 4 / - 0 hours
Note1 : When there are questions concerning measurement result : measurement shall be made after
48 ± 2 hours of recovery under the standard condition