RAIL /// TTDS-022 – HTCM-SCE CABLE MARKER
PAGE 2
CLASS 1 DATA CLASSIFICATION - SEE POLICY TEC-02-04 TE Proprietary Information
Where possible, TE has tested product as a finished item, including the print. Operational tests are followed by an
assessment of mark adherence to validate fit form and function. Further details can be found in TE standard RW-2524.
TECHNICAL DATA SHEET
TTDS-022
High temperature performance
Low vacuum out gassing identification
marker - suitable for use on Spacecraft
Self-extinguishing, non-flame
propagating
Resistant to key military, aviation, rail
and heavy industrial fluids (defined by
RW-2524)
Features
Applications
Post termination Cable Identification
Identification of large cables, wire bundles or pipework
Installation friendly – easy to replace, ideal for retrofitting and repairs. Cable ties are required for fixing
Mass transit, Rail, Aerospace, Marine and Heavy Industrial
Environmental
Does not contain any declarable or prohibited substances from the UNIFE Railway Industry
Substances List
Does not promote mould growth (ASTM G21 – zero rating)
No evolution of substances which may corrode electrical conductors or contacts – up to 200°C (392°F)
Further information and a downloadable declaration covering RoHS and REACH compliance can be
found at the ‘TE Product Compliance Support Centre’:
http://www.te.com/en/resources/product-compliance.html
Temperature Rating
Operating Temperature Range -55°C to 225°C (-67°F to 437°F)
Specifications / Approvals
TE Connectivity Standard RW-2524
Rail EN45545-2, Hazard Classification 3,
In accordance with requirement set R24
Aerospace Airbus Directive ABD0031 Issue F, Fire worthiness require-
ments pressured section of fuselage, (15 s horizontal test –
AITM 2.0003)