The retainer features added protection
against non-insertion or disconnection.
• Housing lance
• Secondary retainers
• Inner-housing lock
• Panel lock construction
Model No.
Note: 1. Punch holes in the panel according to the figures and table shown
above. Burrs must be removed.
2. The strength of the panel must be considered when punching two or
more holes.
3. The connector must be inserted from the same side as the hole is
punched.
Standards ––––––––––––––––––––
0Recognized E60389
1Certified LR20812
2R9351052
Panel Layout and Assembly layout
1
Specifications –––––––––––––––––––
• Current rating:
10 A AC, DC max. (7 A when retainers are mounted)
• Voltage rating: 300 V AC, DC max.
• Temperature range: -25˚C to +90˚C
(including temperature rise in applying
electrical current)
• Contact resistance: Initial value/ 7 mΩmax.
After environmental tests/ 10 mΩmax.
• Insulation resistance: 1,000 MΩmin.
• Withstanding voltage: 1,500 VAC/minute
• Applicable wire: AWG #26 to #16
0.13 to 1.25 mm2
• Applicable panel thickness: 0.7 to 2.0 mm
Note: The current rating varies depending on the number of circuits and the wire
size used in each connector. The table below lists the current rating as a
function of the number of circuits and the wire size.
*Refer to "General Instruction and Notice when using
Terminals and Connectors" at the end of this catalog.
* Contact JST for details.
*Compliant with RoHS.