1
Power entry modules without line filter DF11
www.schurter.com/pg05
Connectors
IEC Appliance Inlet C14 with recessed Circuit Breaker TA45
C14
70° C
Description
- Panel Mount:
Screw-on version from front or rear side, snap-in version from front
side
- 2 Functions:
Appliance Inlet Protection class I, circuit breaker type TA45 2-pole
- Quick connect terminals 6.3 x 0.8 mm
Approvals
- VDE Certificate Number: 40011305
- UL File Number: E96454
Characteristics
- All single elements are already wired
- Switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage- or remote trip release
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
- Unwired versions
- Line switch 1-pole
- Other rocker marking
- Variant with notch for V-Lock mating Cordsets
References
Alternative: version with line filter DF12
Substitute for type 6145
Weblinks
General Product Information, Approvals, RoHS, CHINA-RoHS, Mating
Connectors, e-Store, SCHURTER-Stock-Check, Distributor-Stock-
Check, Accessories
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC 10 A / 250 VAC; 50 Hz
Ratings UL/CSA 1 - 15 A / 250 VAC; 60 Hz
Dielectric Strength > 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
Allowable Operation Temp. -10 °C to 55 °C
Degree of Protection from front side IP 40 acc. to IEC 60529
Protection Class Suitable for appliances with protection
class 1 acc. to IEC 61140
Terminal Quick connect terminals 6.3 x 0.8 mm
Panel Thickness s Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1/1.5/2/2.5/3 mm
Material: Housing Thermoplastic, black, UL 94V-0
Appliance Inlet C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
Circuit Breakers Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In 3A/240VAC : 300A
Line Switch Rocker switch 2-pole, non-illuminated
or illuminated, acc. to IEC 61058-1
Technical details
2
Power entry modules without line filter
DF11
www.schurter.com/pg05
Connectors
Dimensions 91.5 mm
* Version TA45 with undervoltage release
Diagrams
Diagram
1) Line
2) Load
3
Power entry modules without line filter DF11
www.schurter.com/pg05
Connectors
4
Power entry modules without line filter
DF11
www.schurter.com/pg05
Connectors
Technical data (continued)
Circuit breaker
Tripping characteristics
In < 3 A
Tripping characteristics
In >_ 3… <_ 15 A
Effect of ambient temperature 1)
The unit is calibrated for an ambient temperature of +23 °C. To
deter mine the rated current for a lower or higher ambient tempera-
ture, use a correction factor from the table below.
* Ambient temperature [°C] Correction factor
–10 0,89
5 0,91
0 0,92
+23 1,00
+30 1,03
+40 1,08
+55 1,16
Please note that Schurter will establish an internal part number for logistical use in addition to the order
code. The format of this internal part number is, for example DF11.xxxxxxx
* Temperature must be measured at the rear of the breaker next
to the terminals after equipment operating temperature has been
reached.
1) Example
Rated current at +23 °C 6,0 A
Ambient temperature +40 °C
Correction factor 1,08
Chosen rated current at
+ 40 °C ambient temperature 6 A x 1,08 = 6,5 A
10’000
60
2000
1000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
10
5
1
30
20
1,05
Multiple of rated current [ x In ]
10854321,32
Tripping time
Type TA45
Rated current In < 3 A
1-pole protected
2-pole protected
Ambient temp. +23 °C
10’000
60
2’000
1’000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
10
5
1
30
20
1,05
[ x In ]
10854321,32
Type TA45
Rated current I > 3...
< 15 A
1-pole protected
2-pole protected
Ambient temp. +23 °C
Multiple of rated current
Tripping time
n
Order code TA 45
(2-pole rocker-switch without
accessories)
ABTWF150C0 . 0010.019
see table 1
Order code (Order example)
Specials
9 V-Lock-Notch
Wiring
1 wired
2 unwired
Protection class
0 Protection class I
Mounting
0 Screw
1 Snap-in s = 1.0 mm
2 Snap-in s = 1.5 mm
3 Snap-in s = 2.0 mm
4 Snap-in s = 2.5 mm
5 Snap-in s = 3.0 mm
Terminals
1 Quick connect 6.3 x 0.8
00 Without line filter
Type
DF11 .
5
Power entry modules without line filter DF11
www.schurter.com/pg05
Connectors
Packaging unit 20 Pcs
Accessories
Description
0859.0109
Rear Cover
Assorted Covers
Rear Cover
Mating Outlets/Connectors
Category / Description
Appliance OutletOverview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 5092
Appliance Outletfurther types toDF11
ConnectorOverview complete
IEC Connector C15, Rewireable, Straight 0101
IEC Connector C15A, Rewireable, Straight 0102
IEC Connector C15A, Rewireable, Straight 0102-G
IEC Connector C15A, Rewireable, Angled 0112
IEC Connector C13, Rewireable, Angled 4012
Connectorfurther types toDF11 ...
Power CordOverview complete
Power Cord with IEC Connector C13, Angled 0311
Power Cord with IEC Connector C13, Angled 3011
Power Cord with IEC Connector C13, Angled 3012
Power Cord with IEC Connector C13, Angled 3013
Power Cord with IEC Connector C13 3020
Power Cordfurther types toDF11 ...
The specifications, descriptions and illustrations indicated in this document are based on
current information. All content is subject to modifications and amendments.