262 Series LED Digital Indicators Applications * Genset panels Features * Food industry equipment Sealed case front * Process monitor systems Clear bright LED digits allow easy reading from up to 25 feet Customised scaling allows OEM logo and engineering units * Test equipment * Control panels * Dirty environments. Introduction The 262 series are a range of digital panel meters. These meters are versatile in the their measuring range which includes A.C. and D.C. current/voltage. Some versions allow display blanking and hold. Advanced and rugged design allows simple installation and use UL Approved File No. E140758 IP66 (front of panel using optional gasket) The meter front is totally sealed and when panel mounted with an optional gasket is hose proof to IP66, allowing washing and use in wet areas, e.g. food industry, quarries, portable test gear. Other parameters, e.g. Watts, VAr, VA , PF, temperature etc. may be measured using an additional transducer from our transducer range. Panel mounting is quick, with two corner clamps tensioned by thumb screws or alternatively by a quick-fix ratchet. Other than the frequency versions, these instruments can be powered by a variety of A.C. or D.C. supplies. Care has been taken to provide isolation from the measured input signal. Product Code Additionally for DD: Dummy RH zero D.C. Current Multiple D.C. inputs Front External zero + span adjustment External scaling 312 Digits 4 Digits 262-DDA 262-DGA A.C. Current 262-DDB 262-DGB Transducer Input 262-DDT 262-DGT D.C. Voltage 262-DDV 262-DGV A.C. Voltage 262-DDW 262-DGW Tachometer Input 262-DD2 262-DG2 Line Frequency 412 Digits 262-DGH Non-standard update rates Dummy Zero Power Factor 262-DPF 262-DDZ Adjustable brightness display 50mV, 1, 10, 200 & 600V D.C. 262-DDJ Panel Cut-out Additionally for DG: Display blanking Update rate adjustment Display hold - not on DGH/DGF For digital indicators with setpoints, analogue output and Modbus see 262-30 Digital Meter Relays Digital Indicators 1 Web: www.crompton-instruments.com * Email: crompton.info@tycoelectronics.com 2002 262 Series LED Digital Indicators Specification 262-DD RANGE Current & Voltage 262-DG RANGE Current & Voltage 10mV to 600V bipolar 19.99A to 1.999A bipolar 199.9V to 600V A.C. 20mA to 10A A.C. 40Hz to 2kHz including C.T. outputs 1A, 2A, 5A, 10A 50, 60, 75 or 150mV at shunt accuracy 200.0mV to 600V 1mA to 1A bipolar 10-600V A.C. 40Hz to 2kHz 115/230 415 & 480V A.C. 15% 50, 60, 75 or 150mV at shunt accuracy N/A Transducer: 1,5, 10, 20mA, 4 to 20mA 1,5, 10, 20mA, 4 to 20mA N/A N/A Frequency: N/A N/A 35.00 to 99.99Hz 10-99.99Hz 10-999.9Hz 10-9999Hz Signal Conditions Impedance: 10k /Volt D.C., 1k ohm/Volt A.C. 1M D.C. 1k / Volt A.C. Connection Diagrams 262-DGH Line Frequency Self Powered 262-DGF Signal Frequency Input Signal (Specify) 262-DG * Blanking hold common is not isolated from the input. Therefore separate contact must be used for individual isolation. D.C. Voltage D.C. Current A.C. Voltage A.C. Current Shunt N/A or 35.0 to 999.9Hz 262-DGH/F 10 to 60V A.C. 50 to 300V A.C. 100 to 600V A.C. 50k, 270k, 540k Burden Input: - - 3VA at 50Hz - Conversion: Average Sensing A.C. RMS calibrated Average Sensing A.C. RMS calibrated Average Sensing A.C. RMS calibrated Average Sensing A.C. RMS calibrated Overload Protection: Range x 1.2 continuous. Voltage x 1.5 for 10 secs Current x 10 for 3 secs Range x 1.2 continuous. Voltage x 1.5 for 10 secs Current x 10 for 3 secs 1.2 x continuous 1.5 x for 10 seconds 1.2 x continuous 1.5 x for 10 seconds Test Voltage: 2kV rms @ 50Hz for 1 minute input/ auxiliary/case 2kV rms @ 50Hz for 1 minute input/ auxiliary/case 2kV rms @ 50Hz for 1 minute input/ auxiliary/case 2kV rms @ 50Hz for 1 minute input/ auxiliary/case 0.1% of reading 1 count 0.2% of reading 2 counts 0.1% of reading 1 count 0.2% of reading 2 counts 0.2% of reading 2 counts 0.2% of reading 2 counts 0.05% 0.01% 1 count 1 count 120, 230, 240, 415V 15%, 480V optional (40/60Hz) 120, 230, 240, 415V 15%, 480V optional (40/60Hz) N/A 115, 230, 415 D.C. Voltage 12, 24, 48, 120V 20% others on request (max input 156V D.C.) D.C. ripple 30% pk-pk 50/60Hz not available on A.C. ammeters 1 Amp & over 12, 24, 48, 120V 20% others on request (max input 156V D.C.) D.C. ripple 30% pk-pk 50/60Hz not available on A.C. ammeters 1 Amp & over No D.C. auxiliary available No D.C. auxiliary available Display Digits: 1999 full scale 9999 full scale 9999 full scale 9999 Full scale Display Size: 0.56", 14.2mm 7 segment, red 0.56", 14.2mm 7 segment, red 0.56", 14.2mm 7 segment, red 0.56", 14.2mm 7 segment, red Decimal Point: External selection External selection Internal Selection Internal Selection Update: 1 second, (optional up0.4 seconds, optional date rates on application) 0.4 to 6 seconds 2 seconds 2 seconds Over range: 3 R/H digits blank when 1999 is exceeded 3 R/H digits blank when 1999 is exceeded Display blanks (digits only) Display blanks (digits only) Hold: - - Non isolated display hold facility available Non isolated display hold facility available Weight: 0.4kg Ammeters 0.35kg Voltmeters 0.4kg Ammeters 0.35kg Voltmeters 0.25kg 0.35kg Accuracy at 23C 5C OPTION BRIGHTNESS 20K D.C.: A.C.: 262-DDA/B/T/V/W Resolution: Power Supply A.C. Voltage 262-DDJ Information applicable to all Environmental Operating: 0 to 60C (32 to 140F) Burden Auxiliary: Storage: -20 to +70C (-40 to 158F) DIN Case Housing Coefficient: 0.015% per C Zero stability: 1 digit, 0 to 60C (32 to 140F) Humidity: 90% RH non-condensing Warm-up: 1 minute Recalibration: 1 year Shock: 30g in 3 planes 3VA @ 50Hz Enclosure: Totally sealed case front. IP66, NEMA 4. Material: Flame retardant polycarbonate, UL94-V2 Terminals: Barrier type screw clamp - M3.5 (terminal cover provided) Digital Indicators Web: www.crompton-instruments.com * Email: crompton.info@tycoelectronics.com 2002 262 Series LED Digital Indicators A.C. Current, Voltage and Frequency A.C. Current 40-2000Hz - Accuracy 0.2%, 2 Counts Input 1.999mA 20mA 100mA 200mA 1A 2A 5A 10A 3 12 Digit Catalogue No. 4 Digit Catalogue No. *262-DDBU-FG**-C6-PQ** *262-DDBU-HF**-C6-PQ** *262-DDBU-JR**-C6-PQ** *262-DDBU-KA**-C6-PQ** *262-DDBU-LA**-C6-PQ** *262-DDBU-LE**-C6-PQ** *262-DDBU-LS**-C6-PQ** *262-DDBU-MT**-C6-PQ** *262-DGBU-HF**-C6-PQ** *262-DGBU-JR**-C6-PQ** *262-DGBU-KA**-C6-PQ** *262-DGBU-LA**-C6-PQ** *262-DGBU-LE**-C6-PQ** *262-DGBU-LS**-C6-PQ** *262-DGBU-MT**-C6-PQ** A.C. Voltage 40-60Hz Accuracy 0.2% 2 Counts at >20% F.S. Input 3 12 Digit Catalogue No. 4 Digit Catalogue No. 10V 100V 150V 200V 250V 300V 500V 600V *262-DDWU-MTMT-C6-PQ** *262-DDWU-PKPK-C6-PQ** *262-DDWU-PZ**-C6-PQ** *262-DDWU-RLRL-C6-PQ** *262-DDWU-RSRS-C6-PQ** *262-DDWU-RXRX-C6-PQ** *262-DDWU-SFSF-C6-PQ** *262-DDWU-SJSJ-C6-PQ** *262-DGWU-MTMT-C6-PQ** *262-DGWU-PKPK-C6-PQ** *262-DGWU-PZ**-C6-PQ** *262-DGWU-RLRL-C6-PQ** *262-DGWU-RSRS-C6-PQ** *262-DGWU-RXRX-C6-PQ** *262-DGWU-SFSF-C6-PQ** *262-DGWU-SJSJ-C6-PQ** A.C. Frequency Self Powered 4 Digit Input Range MULTI-TAP 120,240 or 480V 35-99.99Hz 35-999.99Hz Catalogue No. *262-DGHU-B5AU-AU-28 *262-DGHU-B5AU-AV-28 A.C. Frequency Aux Powered 4 Digit - Crystal reference time base Input 10-60V 50-300V 100-600V Range PE PG PI 10-99.99Hz 10-999.9Hz 10-9999Hz Catalogue No. 262-DGFU-**PK-PK-PQ-28 262-DGFU-**SS-SS-PQ-28 262-DGFU-**UZ-UZ-PQ-28 Digital Indicators Web: www.crompton-instruments.com * Email: crompton.info@tycoelectronics.com 2002 262 Series LED Digital Indicators D.C. Current and Voltage D.C. Current Accuracy 0.1% 1 Count Input 1mA 2mA 5mA 10mA 20mA 200mA 1/5mA 4-20mA 1AMP 50mV 100mV 3 12 Digit Catalogue No. 4 Digit Catalogue No. *262-DDAU-FA-**-PQ-** *262-DDAU-FG-**-PQ-** *262-DDAU-FX-**-PQ-** *262-DDAU-GZ-**-PQ-** *262-DDAU-HF-**-PQ-** *262-DDAU-KA-**-PQ-** *262-DDAU-GM-**-PQ-** *262-DDAU-HG-**-PQ-** *262-DDAU-LA-**-PQ-** *262-DDAU-EC-**-PQ-** *262-DDAU-GB-**-PQ-** *262-DGAU-FA**-PQ-** *262-DGAU-FG**-PQ-** *262-DGAU-FX**-PQ-** *262-DGAU-GZ**-PQ-** *262-DGAU-HF**-PQ-** *262-DGAU-KA**-PQ-** *262-DGAU-GM**-PQ-** *262-DGAU-HG**-PQ-** *262-DGAU-LA**-PQ-** *262-DGAU-EC**-PQ-** *262-DGAU-GB**-PQ-** D.C. Transducer Indicator - Accuracy 0.1% 1 Count Input 1mA 20mA 4-20MA 3 12 Digit Catalogue No. 4 Digit Catalogue No. *262-DDTU-FA**-PQ-** *262-DDTU-HF**-PQ-** *262-DDTU-HG**-PQ-** *262-DGTU-FA**-PQ-** *262-DGTU-HF**-PQ-** *262-DGTU-HG**-PQ-** Multiple D.C. Voltage Input Customer Selectable 3 12 Digit and Decimal point Inputs Catalogue No. 50mV, 1V, 10V, 200V, 600V *262-DDJU-ZZ**-PQ-** D.C. Voltage 0.1% 1 Count Input 20mV 200mV 2V 10V 20V 200V 250V 300V 500V 600V 3 12 Digit Catalogue No. 4 Digit Catalogue No. *262-DDVU-HF**-PQ-** *262-DDVU-KA**-PQ-** *262-DDVU-LE**-PQ-** *262-DDVU-MT**-PQ-** *262-DDVU-NG**-PQ-** *262-DDVU-RL**-PQ-** *262-DDVU-RS**-PQ-** *262-DDVU-RX**-PQ-** *262-DDVU-SF**-PQ-** *262-DDVU-SJ**-PQ-** *262-DGVU-KA**-PQ-** *262-DGVU-LE**-PQ-** *262-DGVU-MT**-PQ-** *262-DGVU-NG**-PQ-** *262-DGVU-RL**-PQ-** *262-DGVU-RS**-PQ-** *262-DGVU-RX**-PQ-** *262-DGVU-SF**-PQ-** *262-DGVU-SJ**-PQ-** Options 262-DDZ 412 digit with fixed zero least significant Digit (19990 counts) Offset calibration i.e., 1-5V Neoprene panel mounting gasket Externally adjustable display dimming (only DD) D.C. auxiliary supply (isolated) Externally adjustable span potentiometer back panel accessible 12V D.C. or 24V D.C. Switchboard mounting adaptor 48V D.C. - 125V D.C. ** Specify preferred range, option, input option and auxiliary supply. * UL recognized Digital Indicators Web: www.crompton-instruments.com * Email: crompton.info@tycoelectronics.com 2002