https://www.phoenixcontact.com/us/products/2864150 Signal conditioner - MINI MCR-SL-UI-UI-NC - 2864150 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://download.phoenixcontact.com) 3-way isolating amplifier for the electrical isolation of analog signals, I/O can be configured via DIP switches, with screw connection, standard configuration Product Features Power supply possible via the foot element (T-connector) Up to 36 signal combinations can be configured using DIP switches Low power consumption Highly-compact isolating amplifier for electrical isolation, conversion, amplification, and filtering of standard analog signals 3-way isolation Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 85.0 GRM Custom tariff number 85437090 Country of origin Germany Technical data Note: Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 6.2 mm Height 93.1 mm Depth 102.5 mm Ambient conditions 04/09/2014 Page 1 / 8 https://www.phoenixcontact.com/us/products/2864150 Signal conditioner - MINI MCR-SL-UI-UI-NC - 2864150 Technical data Ambient conditions Ambient temperature (operation) -20 C ... 65 C Ambient temperature (storage/transport) -40 C ... 85 C Degree of protection IP20 Input data Configurable/programmable Yes, unconfigured Voltage input signal 0 V ... 10 V 0 V ... 5 V 1 V ... 5 V 2 V ... 10 V Current input signal 0 mA ... 20 mA 4 mA ... 20 mA Max. input voltage 30 V Max. input current 50 mA Input resistance of voltage input approx. 100 k Input resistance current input approx. 50 Output data Configurable/programmable Yes, unconfigured Voltage output signal 0 V ... 10 V 0 V ... 5 V 1 V ... 5 V 2 V ... 10 V Current output signal 0 mA ... 20 mA (please indicate if different setting when ordering) 4 mA ... 20 mA Max. output voltage approx. 12.5 V Max. output current 28 mA Short-circuit current approx. 22 mA Load/output load voltage output 10 k Load/output load current output < 500 (at 20 mA) Power supply Nominal supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (The T connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) Max. current consumption < 19 mA (Current output, at 24 V DC incl. load) < 9 mA (Voltage output, at 24 V DC incl. load) Power consumption < 450 mW (Current output) < 200 mW (Voltage output) 04/09/2014 Page 2 / 8 https://www.phoenixcontact.com/us/products/2864150 Signal conditioner - MINI MCR-SL-UI-UI-NC - 2864150 Technical data Connection data Connection method Screw connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 2.5 mm Conductor cross section AWG/kcmil min. 26 Conductor cross section AWG/kcmil max 12 Conductor cross section stranded min. 0.2 mm Conductor cross section stranded max. 2.5 mm Stripping length 12 mm Screw thread M3 General No. of channels 1 Maximum transmission error 0.1 % (of final value) < 0.4 % (Without adjustment) Maximum temperature coefficient < 0.01 %/K Temperature coefficient, typical < 0.002 %/K Limit frequency (3 dB) approx. 100 Hz Step response (10-90%) approx. 3.2 ms Protective circuit Transient protection Electrical isolation Basic insulation according to EN 61010 Surge voltage category II Pollution degree 2 Rated insulation voltage 50 V AC/DC Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color green Housing material PBT Mounting position any Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. Conformance CE-compliant ATEX II 3 G Ex nA IIC T4 Gc X UL, USA / Canada UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL GL EMC 2 D 04/09/2014 Page 3 / 8 https://www.phoenixcontact.com/us/products/2864150 Signal conditioner - MINI MCR-SL-UI-UI-NC - 2864150 Technical data EMC data Name Electromagnetic RF field Standards/regulations EN 61000-4-3 Typical deviation from the measuring range final value 5% Name Fast transients (burst) Standards/regulations EN 61000-4-4 Typical deviation from the measuring range final value 5% Name Conducted interferences Standards/regulations EN 61000-4-6 Typical deviation from the measuring range final value 5% Classifications eCl@ss eCl@ss 4.0 27210120 eCl@ss 4.1 27210120 eCl@ss 5.0 27210120 eCl@ss 5.1 27210120 eCl@ss 6.0 27210120 eCl@ss 7.0 27210120 eCl@ss 8.0 27210120 ETIM ETIM 2.0 EC001485 ETIM 3.0 EC001485 ETIM 4.0 EC001485 ETIM 5.0 EC001485 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 Approvals Approvals 04/09/2014 Page 4 / 8 https://www.phoenixcontact.com/us/products/2864150 Signal conditioner - MINI MCR-SL-UI-UI-NC - 2864150 Approvals Approvals UL Recognized / cUL Recognized / GL / cULus Recognized Ex Approvals UL Listed / cUL Listed / ATEX / cULus Listed Approvals submitted Approval details UL Recognized cUL Recognized GL cULus Recognized Accessories Accessories DIN rail connector Electronic housing - ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - 2869728 DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos. Marking material 04/09/2014 Page 5 / 8 https://www.phoenixcontact.com/us/products/2864150 Signal conditioner - MINI MCR-SL-UI-UI-NC - 2864150 Accessories Transparent cover - MINI MCR DKL - 2308111 Fold up transparent cover for MINI MCR modules with additional labeling option using insert strips and flat Zack marker strip 6.2 mm Marking label - MINI MCR-DKL-LABEL - 2810272 Label for extended marking of MINI MCR modules in connection with the MINI MCR-DKL Power module Power terminal block - MINI MCR-SL-PTB - 2864134 MCR power terminal block for supplying several MINI Analog modules via the T-connector, with screw connection, maximum current consumption of up to 2 A Power terminal block - MINI MCR-SL-PTB-SP - 2864147 MCR power terminal block for supplying several MINI Analog modules via the T-connector, with spring-cage connection, maximum current consumption of up to 2 A Power supply Power supply unit - MINI-SYS-PS-100-240AC/24DC/1.5 - 2866983 DIN rail power supply unit, primary-switched mode, slim design, output: 24 V DC / 1.5 A 04/09/2014 Page 6 / 8 https://www.phoenixcontact.com/us/products/2864150 Signal conditioner - MINI MCR-SL-UI-UI-NC - 2864150 Accessories Power supply unit - MINI-PS-100-240AC/24DC/1.5/EX - 2866653 DIN rail power supply unit, primary-switched mode, slim design, output: 24 V DC / 1.5 A, ATEX approval System adapter System adapter - MINI MCR-SL-V8-FLK 16-A - 2811268 Eight MINI analog signal converters with screw connection method can be connected to a control system using a system adapter and system cabling with a minimum of wiring and very low error risk. Drawings Block diagram Dimensioned drawing 93,1 + 1 IN U,I OUT U,I 5 + 5 active 4-wire GND 2 - 2 + 3 - 4 GND 1 +24V passive GND 2 6 - +24V GND 3 6,2 PLC / DCS 6 7 + GND 3 8 - 102,5 OUT 1 U,I US OUT IN Sensor / Field +24V GND 3 Zone 2 Div. 2 04/09/2014 Page 7 / 8 https://www.phoenixcontact.com/us/products/2864150 Signal conditioner - MINI MCR-SL-UI-UI-NC - 2864150 Application drawing 24V Level gauge 0...10V 0...20mA 1 IN OUT 5 2 GND1 GND2 6 Control system 3 UB+ UB+ 7 4 GND3 GND3 8 MINI MCR-SL-UI-UI 24V Mains voltage Phoenix Contact 2014 (c) - all rights reserved http://www.phoenixcontact.com 04/09/2014 Page 8 / 8