3-way isolating amplifier for the electrical isolation of analog signals, I/O can be configured via DIP switches, with
screw connection, standard configuration
Product Features
Power supply possible via the foot element (T-connector)
Up to 36 signal combinations can be configured using DIP switches
Low power consumption
Highly-compact isolating amplifier for electrical isolation, conversion, amplification, and filtering of standard analog signals
3-way isolation
Key commercial data
Packing unit 1 pc
Weight per Piece (excluding packing) 85.0 GRM
Custom tariff number 85437090
Country of origin Germany
Technical data
Note:
Utilization restriction EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width 6.2 mm
Height 93.1 mm
Depth 102.5 mm
Ambient conditions
https://www.phoenixcontact.com/us/products/2864150
04/09/2014Page2/8
Signal conditioner-MINI MCR-SL-UI-UI-NC-2864150
Technical data
Ambient conditions
Ambient temperature (operation) -20 °C ... 65 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Degree of protection IP20
Input data
Configurable/programmable Yes, unconfigured
Voltage input signal 0 V ... 10 V
0 V ... 5 V
1 V ... 5 V
2 V ... 10 V
Current input signal 0 mA ... 20 mA
4 mA ... 20 mA
Max. input voltage 30 V
Max. input current 50 mA
Input resistance of voltage input approx. 100 kΩ
Input resistance current input approx. 50 Ω
Output data
Configurable/programmable Yes, unconfigured
Voltage output signal 0 V ... 10 V
0 V ... 5 V
1 V ... 5 V
2 V ... 10 V
Current output signal 0 mA ... 20 mA (please indicate if different setting when ordering)
4 mA ... 20 mA
Max. output voltage approx. 12.5 V
Max. output current 28 mA
Short-circuit current approx. 22 mA
Load/output load voltage output ≥ 10 kΩ
Load/output load current output < 500 Ω (at 20 mA)
Power supply
Nominal supply voltage 24 V DC
Supply voltage range
19.2 V DC ... 30 V DC (The T connector (ME 6,2 TBUS-2 1,5/5-ST-3,81
GN, Order No. 2869728) can be used to bridge the supply voltage. It can
be snapped onto a 35 mm DIN rail according to EN60715))
Max. current consumption < 19 mA (Current output, at 24 V DC incl. load)
< 9 mA (Voltage output, at 24 V DC incl. load)
Power consumption < 450 mW (Current output)
< 200 mW (Voltage output)
https://www.phoenixcontact.com/us/products/2864150
04/09/2014Page3/8
Signal conditioner-MINI MCR-SL-UI-UI-NC-2864150
Technical data
Connection data
Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section AWG/kcmil min. 26
Conductor cross section AWG/kcmil max 12
Conductor cross section stranded min. 0.2 mm²
Conductor cross section stranded max. 2.5 mm²
Stripping length 12 mm
Screw thread M3
General
No. of channels 1
Maximum transmission error ≤ 0.1 % (of final value)
< 0.4 % (Without adjustment)
Maximum temperature coefficient < 0.01 %/K
Temperature coefficient, typical < 0.002 %/K
Limit frequency (3 dB) approx. 100 Hz
Step response (10-90%) approx. 3.2 ms
Protective circuit Transient protection
Electrical isolation Basic insulation according to EN 61010
Surge voltage category II
Pollution degree 2
Rated insulation voltage 50 V AC/DC
Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC
Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal
deviations.
Color green
Housing material PBT
Mounting position any
Assembly instructions The T connector can be used to bridge the supply voltage. It can be
snapped onto a 35 mm DIN rail according to EN 60715.
Conformance CE-compliant
ATEX  II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GL GL EMC 2 D
https://www.phoenixcontact.com/us/products/2864150
04/09/2014Page4/8
Signal conditioner-MINI MCR-SL-UI-UI-NC-2864150
Technical data
EMC data
Name Electromagnetic RF field
Standards/regulations EN 61000-4-3
Typical deviation from the measuring range final value 5 %
Name Fast transients (burst)
Standards/regulations EN 61000-4-4
Typical deviation from the measuring range final value 5 %
Name Conducted interferences
Standards/regulations EN 61000-4-6
Typical deviation from the measuring range final value 5 %
Classifications
eCl@ss
eCl@ss 4.0 27210120
eCl@ss 4.1 27210120
eCl@ss 5.0 27210120
eCl@ss 5.1 27210120
eCl@ss 6.0 27210120
eCl@ss 7.0 27210120
eCl@ss 8.0 27210120
ETIM
ETIM 2.0 EC001485
ETIM 3.0 EC001485
ETIM 4.0 EC001485
ETIM 5.0 EC001485
UNSPSC
UNSPSC 6.01 30211506
UNSPSC 7.0901 39121008
UNSPSC 11 39121008
UNSPSC 12.01 39121008
UNSPSC 13.2 39121008
Approvals
Approvals
https://www.phoenixcontact.com/us/products/2864150
04/09/2014Page5/8
Signal conditioner-MINI MCR-SL-UI-UI-NC-2864150
Approvals
Approvals
UL Recognized / cUL Recognized / GL / cULus Recognized
Ex Approvals
UL Listed / cUL Listed / ATEX / cULus Listed
Approvals submitted
Approval details
UL Recognized
cUL Recognized
GL
cULus Recognized
Accessories
Accessories
DIN rail connector
Electronic housing-ME 6,2 TBUS-2 1,5/5-ST-3,81 GN-2869728
DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos.
Marking material
https://www.phoenixcontact.com/us/products/2864150
04/09/2014Page6/8
Signal conditioner-MINI MCR-SL-UI-UI-NC-2864150
Accessories
Transparent cover-MINI MCR DKL-2308111
Fold up transparent cover for MINI MCR modules with additional labeling option using insert strips and flat Zack marker
strip 6.2 mm
Marking label-MINI MCR-DKL-LABEL-2810272
Label for extended marking of MINI MCR modules in connection with the MINI MCR-DKL
Power module
Power terminal block-MINI MCR-SL-PTB-2864134
MCR power terminal block for supplying several MINI Analog modules via the T-connector, with screw connection,
maximum current consumption of up to 2A
Power terminal block-MINI MCR-SL-PTB-SP-2864147
MCR power terminal block for supplying several MINI Analog modules via the T-connector, with spring-cage connection,
maximum current consumption of up to 2A
Power supply
Power supply unit-MINI-SYS-PS-100-240AC/24DC/1.5-2866983
DIN rail power supply unit, primary-switched mode, slim design, output: 24 V DC / 1.5 A
https://www.phoenixcontact.com/us/products/2864150
04/09/2014Page7/8
Signal conditioner-MINI MCR-SL-UI-UI-NC-2864150
Accessories
Power supply unit-MINI-PS-100-240AC/24DC/1.5/EX-2866653
DIN rail power supply unit, primary-switched mode, slim design, output: 24 V DC / 1.5 A, ATEX approval
System adapter
System adapter-MINI MCR-SL-V8-FLK 16-A-2811268
Eight MINI analog signal converters with screw connection method can be connected to a control system using a system
adapter and system cabling with a minimum of wiring and very low error risk.
Drawings
Block diagram
Zone 2
Div. 2
passive
IN
Sensor / Field
OUT
PLC / DCS
4-wire
+
+
+
+
+24V
+24V
+24V
GND 3
GND 3
GND 2
active
GND 3
GND 1
OUT U,IIN U,I
1 5
26
7
8
3
4
OUT
U,I
GND
US
5
6
1
2
Dimensioned drawing
93,1 6,2
102,5
https://www.phoenixcontact.com/us/products/2864150
04/09/2014Page8/8
Signal conditioner-MINI MCR-SL-UI-UI-NC-2864150
Application drawing
0...20mA
24V
0...10V
24V
MINIMCR-SL-UI-UI
51
2
3
4
6
7
8
GND3
GND1
IN
GND2
OUT
UB+ UB+
GND3
Controlsystem
Levelgauge
Mainsvoltage