HI-AMP Reset Circuit Protectors Series 180
Signle Pole Ther mal Type Breakers
Auto, Manual & Switchable
Form No. 180 Hi-Amp
Page 1 of 1
BIF Document: 2065
Bussmann®
Rev. ASB98107
12-16-98
SPECIFICATIONS
Single Pole Thermal Type Breakers
Ratings: 40A to 150A; 30 VDC.
Operating Temperature: –25°F (–32°C) to 180°F (82°C).
Storage Temperature: –30°F (–34°C) to 300°F (149°C).
Applications: Typically used in auxiliary and accessory circuits -- trucks,
buses, RV’s and marine applications. Others might include battery chargers
and DC audio systems. Series 181, 184 & 185 are sealed for engine com-
partment and bilge area applications.
Housing: Thermoset plastic; UL rated 94VO; 311°F (155°C). Stud insulators
are provided on all covered units.
Mounting: Panel or surface.
Indicator: Series 184 & 185 have a unique reset mechanism which provides
visible indication of tripped condition.
Approvals: Complies with SAE Standard J1625
PART NUMBERING SYSTEM
Series
❏❏❏
18
181 – Auto Reset
183 – Auto Reset
184 – Manual Reset
185 – Switchable/Manual
Rating
❏❏❏
040 – 40amps
050 – 50 amps
060 – 60 amps
070 – 70 amps
080 – 80 amps
090 – 90 amps
100 – 100 amps
110 – 110 amps
120 – 120 amps
135 – 135 amps
150 – 150 amps
Mounting
❏–
F – Surface Mount
P – Panel Mount
Terminal Hdwr.
❏❏
00 – Ship w/o nuts
01 – Sems nuts installed
02 – Sems nuts shipped bulk
03 – Stainless Steel Std. nuts &
washers installed
04 – Stainless Steel Std. nuts &
washers shipped bulk
05 – Sems nuts - bulk/eyelets installed
06 – Sems nuts & eyelets installed
07 – Flange gasket & Sems nuts installed
08 – Threaded insert & Sems nuts installed
Marking
❏❏
0 – Blank cover
1 – Standard Marking; Part Number,
Amp Rating
181, 184, 185 Series - Top Surface
183 Series - Side Surface
Consult factory for special markings.
.26" (6.60) dia.
.26" (6.60) dia. Mtg.holes (2) Reset lever