www.osram-americas.com/LED PrevaLED(R) Flex Linear Flexible LED light engine Key Features & Benefits ---- FPC board with a 76mm (3") bending radius to allow for curved luminaire design ---- Poke-in style connector to allow for multiple attachment points throughout the module length ---- Available in two reel lengths - 28m (91.9ft) and 5.6m (18.4ft) ---- Thermally independent requiring no additional heat sinking ---- Multiple cutting points allow custom- ---- Fully dimmable ers to tailor to desired product length ---- Long life: greater than 50,000 (L70) ---- Available 93mm (3.7") cutting resohours minimizing maintenance frelution after the minimum length of quency at operating temperatures 1 SEU of 281mm (11") is reached up to 75C ---- Zhaga Book 7 mounting hole pattern ---- 5 year system warranty when paired with OPTOTRONIC(R) constant current LED power supplies The PrevaLED Flex Linear LED offers a high efficiency flexible light engine for use in general lighting luminaires or creative luminaire designs with curved surfaces, long linear lengths, or unique dimensions. The flexible printed circuit (FPC) board with 3" bending radius and multiple cut points simplifies incorporation into luminaires. Product Offering Length 18.4 ft (5.6m), 91.9 ft (28m) Lumens per ft. 1100 Color Temperature 3000, 3500, 4000, 5000K The PrevaLED Flex Linear LED light engines are optimally paired with OPTOTRONIC constant current LED power supplies and such systems are covered by a 5 year warranty. Application Information Applications ---- Cove lighting ---- Curved luminaires ---- General lighting ---- Industrial lighting ---- Retail LED402R2 2-16 Specifications and Certifications The OSRAM PrevaLED Flex Linear is UL8750 Recognized for the US and Canada Class 2 Units (UL File # E320662) Specification Data Catalog # Type Project Comments Prepared by Ordering Information Item Ordering Number Abbreviation 73863 PFLZ1-LIN-1100-830-20X281X40 73864 PFLZ1-LIN-1100-835-20X281X40 73865 PFLZ1-LIN-1100-840-20X281X40 73866 PFLZ1-LIN-1100-850-20X281X40 73867** PFLZ1-LIN-1100-830-100X281X40 73868** PFLZ1-LIN-1100-835-100X281X40 73869** PFLZ1-LIN-1100-840-100X281X40 73870** PFLZ1-LIN-1100-850-100X281X40 Nominal Wattage (W)* 7.2 7.2 7.2 6.5 7.2 7.2 7.2 6.5 Max Wattage (W) 11 11 11 11 11 11 11 11 Input Voltage (V) 30 30 30 30 30 30 30 30 OperatingLED Current (mA)* Pitch Typical Max. (mm) 245 360 9.3 245 360 9.3 245 360 9.3 224 360 9.3 245 360 9.3 245 360 9.3 245 360 9.3 224 360 9.3 Initial Lumens Dimensions (lm)* CCT CRI LPW (LxW) 1100 3000K >80 153 281x40 1100 3500K >80 153 281x40 1100 4000K >80 153 281x40 1100 5000K >80 169 281x40 1100 3000K >80 153 281x40 1100 3500K >80 153 281x40 1100 4000K >80 153 281x40 1100 5000K >80 169 281x40 281mm/ Reel Qty. 20 20 20 20 100 100 100 100 Case Qty. 8 8 8 8 6 6 6 6 * Data refers to 1 Smallest Electrical Unit (SEU) of 281mm (11") length. The LED Modules are designed to have consistent lumen output across all CCTs. Nominal rating at board Tc of 45C. ** Coming soon. Ordering Guide PFL Z1 - LIN - 1100 - 8 Product Zhaga Gen 1 Linear Lumen Package CRI >80 PrevaLED (R) Flex Linear 30 - 100 x 281 x 40 CCT Number of 281mm Size of Smallest Width in mm 30 = 3000K modules per 28m reel Electrical Unit (SEU) 35 = 3500K in mm 40 = 4000K 50 = 5000K Power Supply Information OPTOTRONIC(R) Compact Programmable PFLZ1-LIN-1100-8xx-20x281x40 OPTOTRONIC Linear Programmable OPTOTRONIC Linear Step-Dim OT25W OT40W OT30W OT48W OT50W OTi85 OT30W OT50W * * * * * * * * Notes: Please check power rating (wattage, current and voltage) limitations of driver when connecting module. For up to 5 SEUs length module can be powered up from either end or middle. For lengths >5 SEUs up to 8 SEUs, the module needs to be powered from the middle. For applications requiring more than 8 SEUs, cut the modules at designated cut points and connect directly to the output of the power supply. Ensure the total power drawn by the module is within the power supply limit. Minimum and Maximum Ratings Parameter Operating Tc Temperature Storage Temperature Minimum Operating Length Values 75C (158F) -20 to 85C (-40 to 176F) 1 SEU of 281mm (11") Assembly Diagram 281 LED Pitch: 9,37 Cut line 12,7 3,90 31 4 0,50 Cut line 93,67 6 x 1,85 0,2 93,67 3 4,70 18,40 56 1206 Pitch: 93,66 Maximum operable length : 1.405m --> 5 x 281mm modules supplied from one end 2.248m --> 8 x 281mm modules supplied from the middle Slot Pattern Pitch: 93,33 9,25 4,05 33,34 3,90 16,67 4 0,50 4 0,50 4,68 3 x 1,85 0,20 15 3 20 40 7,70 Wiring Diagram Modules up to 5 SEUs in length can be wired from either end. + - LED Driver RED + - BLUE RED BLUE + - LED Driver + - Modules in lengths of >5 SEUs to 8 SEUs need to be powered from the middle. Modules can also be connected in parallel branches up to 5 SEUs as long as the load is within the power supply output rating. + + - LED Driver + - - RED LED Driver BLUE + - RED BLUE + - Modules powered in a series connection is not recommended. LED Driver RED + - BLUE + + + + - - - - Note: In all cases ensure that output (current, voltage, wattage) is within power supply limitations/spec. Safety Information WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION. TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OF THE POWER SUPPLIES AND/OR MODULES. Failure to install the power supplies and/or LED modules in accordance with the National Electric Code (NEC), all applicable Federal, State and local electric codes as well as the specific Underwriters Laboratories (UL) safety standards for the installation, location and application may cause serious personal injury, death, property damage and/or product malfunction. 1. T he LED module itself and all its components shall not be subjected to mechanical stress and assembly must not damage or destroy conducting paths on the circuit board. 2. O bserve correct electrical polarity, incorrect polarity may destroy the module. (Depending on the product, incorrect polarity may lead to emission of red or no light.) 3. Ensure the power supply is of adequate power to operate the total load. 4. Electrostatic Discharge (ESD) precautions shall be incorporated when handling or installing the module. (For more information, reference document # LED093 ESD Protection for LED Systems.) 5. Installation of LED modules shall be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. 6. Modules may be hot to the touch. Use caution when handling. 7. D amage by corrosion and improper heat sinking will not be honored as a materials defect claim. It is the user's responsibility to ensure adequate heat sink and protection against corrosive agents such as moisture, condensation and other harmful elements. Assembly Information 1. The PrevaLED Flex Linear LED module needs no supplemental heat sinking when the temperature at Tc point is maintained at or below 75C. 2. Service life is 60,000 hours/L 70 when the Tc temperature is maintained. 3. W hen the environment is unknown, PrevaLED Flex Linear modules should be installed in luminaires designed to provide proper thermal management to avoid premature failure of the product and to obtain expected service life. a. S ervice life (i.e. lumen depreciation) is primarily a function of LED temperature, which is to be monitored on the circuit board at the designated "Tc Point." b. Tc Point temperature measurements should be taken with the modules operating at thermal equilibrium in potential fixture designs installed in an appropriate environment. c. Due to variation in fixture designs, there is no exact installation prescription for obtaining an appropriate Tc point temperature. 4. The Smallest Electrical Unit can be removed by cutting with scissors on the designated cut points. a. C utting points are clearly marked every 93mm on each module. Cutting can only start at length longer than 281mm. Using less than 281mm is not approved for UL. b. Poke-in style connectors are present every 281mm. Power can be applied to any connection along the module length, typically at the end or in the middle based on application requirement. c. 18 AWG solid core wire is preferred for connections to driver. d. The module can be mounted onto a fixture or any metal surface by means of mechanical fasteners (screws, rivets, push-to fix, fixing elements). Typical assembly requires minimum of three mechanical fasteners per every 2ft length of the module for secure mounting. If choosing metal screws/fasteners ensure the metal screw head does not go beyond the designated screw area. 5. P arallel connection is highly recommended as safe electrical mode. Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload and damage the LED module. Note: For additional product and installation instructions please see application guide Warranty OSRAM LED products are covered by our LED Module, OPTOTRONIC (R) Power Supply or Control warranty. The PrevaLED (R) Flex Linear is covered under this warranty as long as the temperature at the Tc point does not exceed 70C; exceeding this temperature will void all warranties. For additional information or to download the warranty registration form, refer to the latest version of the warranty (LED089) available in the literature section of www.osram-americas.com. Module Warranty: 3 years System Warranty: 5 years Americas Headquarters OSRAM SYLVANIA Inc. 200 Ballardvale Street Wilmington, MA 01887 USA Phone 1-800-LIGHTBULB (1-800-544-4828) www.osram-americas.com OSRAM, PrevaLED, LED CREATING TOMORROW and OPTOTRONIC are registered trademarks of OSRAM GmbH. Specifications subject to change without notice. . (c) 2016 OSRAM