Circuit Protection Products for the Electrical Industry New Products for All Markets For product data sheets, visit www.cooper.bussmann.com/products/datasheet.asp Circuit Protection Products for the Electrical Industry Table of Contents RED indicates NEW information Selecting Circuit Protection . . . . . . . . . . . . . . . . . .6-10 2005 NEC(R) guide to fuse selection for various applications . . . .6-10 Low Voltage, Branch Circuit Rated Fuses . . . . . . .11-42 Holders & blocks for branch circuit rated fuses . . . . . . . . . . . .12-14 Dimensions data for branch circuit rated fuses . . . . . . . . . . . . .15-16 Class CC LP-CC Low-Peak(R) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 FNQ-R CC-Tron(R) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 KTK-R Limitron(R) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Class CF TCF, TCF_RN & TCFH_N CUBEFuse(R) and holders . . . . . . . . . . .20-21 Class G SC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Class J LPJ-_SP & LPJ-_SPI Low-Peak . . . . . . . . . . . . . . . . . . . . . . . . . .23 JKS Limitron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Class K5 & H NON (250V) & NON (600V) One time . . . . . . . . . . . . . . . . . . . . . .25 Class L KRP-C_SP Low-Peak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26-27 KRP-CL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 KTU & KLU Limitron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Class RK1 LPN-RK_SP & LPN-RK_SPI (250V) Low-Peak . . . . . . . . . . . . .29-31 LPS-RK_SP & LPS-RK_SPI (600V) Low-Peak . . . . . . . . . . . . . .29-31 KTN-R (250V) Limitron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 KWS-R (600V) Limitron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 Class RK5 DLN-R (250V) & DLS-R (600V) Dura-Lag . . . . . . . . . . . . . . . . . . .34 FRN-R (250V) Fusetron(R) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 FRS-R (600V) Fusetron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 PVS-R (600V) Limitron PV fuse . . . . . . . . . . . . . . . . . . . . . . . . . . .37 Class T JJN (300V) T-Tron(R) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 JJS (600V) T-Tron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 Edison Base & Rejection Plug Fuses Plug Fuses (S, SL, T, TL & W) . . . . . . . . . . . . . . . . . . . . . . . . .40-41 MB Edison Base Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . .42 SA Rejection-base plug fuse adapters . . . . . . . . . . . . . . . . . . . . . .42 Low Voltage Supplementary Fuses . . . . . . . . . . .43-56 Holders & blocks for supplemental fuses . . . . . . . . . . . . . . . . .44-45 Cable (K Series) & Welder (64000/68000 Series) Limiters . . . . . . .46 13 32" x 1 12" fuses BAF, KTK, KLM & DCM . . . . . . . . . . . . . . . . . . . .47 10x38mm Solar PV fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 13 32" x 1 12" fuses FNM & FNQ . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Low Voltage Supplementary Fuses (Continued) 32" x 1 38" fuses BBS & KTQ . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 Pin indication fuses GBA/GLD, MIC & MIN, FNA, MIS & KAZ . . .51-52 Limiters & blocks ANL & ANN . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 In-line size rejecting fuses and holders GLQ, GMQ, HLQ . . . . . . . . .53 In-line non-rejecting fuses and holders GLR, GMF, GRF, HLQ . . . . .54 Automotive blade fuses and holders ATM, ATC, MAX . . . . . . . .55-56 13 Electronic - PC Board and Small Dimension Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57-70 5 x 15mm Ferrule fuses C515, C516, C517, C518, C519, C520 . .58 5 x 20mm European (IEC) fuses S500, S501, S505, S506, GDA, GDB, GDC . . . . . . . . . . . . .59-60 5 x 20mm North American (UL) fuses GMA, GMC, GMD- . . . . . . . .61 1 4" Diameter x 58" to 1" length ferrule fuses AGA, AGW, AGX . . . . . .62 1 4" Diameter x 1 14" length fast-acting ferrule fuses ABC, AGC, GBB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 1 4" Diameter x 1 14" length time-delay ferrule fuses MDA, MDL, MDQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 PC Board mount fuse holders HTC-, HBH-, HBV-, HBW-, FBI, FBM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65-66 PC Board fuseclips HTC-_M, 1A_, 56_ . . . . . . . . . . . . . . . . . .67-70 Medium Voltage Fuses . . . . . . . . . . . . . . . . . . . . .71-91 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72 E-Rated fuses for transformers & feeders . . . . . . . . . . . . . . . .73-75 E-Rated fuses: CL-14 & bolt-in . . . . . . . . . . . . . . . . . . . . . . . .76-77 E-Rated fuses for potential & small power transformers . . . . . .78-79 R-Rated fuses for motor circuit protection . . . . . . . . . . . . . . . .80-82 British Standard IEC fuses for motor circuit protection . . . . . . . . . .83 DIN IEC fuses for transformers . . . . . . . . . . . . . . . . . . . . . . . . . . .84 Potential transformer fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85 British Standard IEC fuses for oil filled switchgear . . . . . . . . . .86-87 EEI-NEMA Type K & T, and Type H & N fuses . . . . . . . . . . . . . . . . .88 BBU Boric acid fuses BBU . . . . . . . . . . . . . . . . . . . . . . . . . . . .89-90 Fuseclips for medium voltage fuses . . . . . . . . . . . . . . . . . . . . . . .91 High Speed Semiconductor Fuses . . . . . . . . . . .93-216 General Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94-95 North American fuses and accessories DFJ, FWA, FWH, FWJ, FWP, FWX, KAC, KBC, . . . . . . . . . .96-113 Square body fuses and accessories DIN 43 620, DIN 43 653, flush-end contact, French Style, US Style 170E, 170F, 170H, 170M . . . . . . . . . . . . . . . . .114-186 British BS 88 fuses and accessories CT, ET, EET, FE, FEE, FM, FMM, LCT, LET, LMMT, LMT, MMT, MT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187-195 Ferrule fuses and accessories FWA, FWC, FWH, FWJ, FWK, FWL, FWP, FWS, FWX . . . . .196-216 Cooper Bussmann circuit protection solutions comply with major industrial standards and agency requirements such as: BS, IEC, DIN, UL, NEMA, CSA, CE, C-UL, etc. and are manufactured at facilities that are ISO 9000 certified. This catalog is intended to present product data and provide technical information that will help the end user with design application. Cooper Bussmann reserves the right, without notice, to change design or construction or any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this catalog. Once a product has been selected, it should be tested by the user in all possible applications. Further, Cooper Bussmann takes no responsibility for errors or omissions contained in this catalog, or for mis-application of any Cooper Bussmann product. Extensive product information is available in the Bussmann product data sheets available on line at www.cooperbussmann.com/products/datasheet.asp. (c)2010 Cooper Bussmann For product Data Sheets, visit www.cooperbussmann.com/datasheets/ulcsa 3 Circuit Protection Products for the Electrical Industry Table of Contents RED indicates NEW information IEC & British Standard Fuses . . . . . . . . . . . . . .217-235 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217-218 CSA Type P and Type D fuses CDN, CDS, PON . . . . . . . . . . . . . .219 HRC Form II Class C Tron(R) fuses CGL . . . . . . . . . . . . . . . . . . . . .220 HRCI Industrial ceramic body fuses CIF . . . . . . . . . . . . . . . . . . . .221 HRCI-J Fast-acting fuses CJ . . . . . . . . . . . . . . . . . . . . . . . . . . . .222 MRCI-Miscellaneous Type K fuses CIH, CIK, CIL . . . . . . . . . . . . . .223 HRC Form II Current-limiting fuses H07C, K07C, L09C, L14C, M09C, M14C, P09C, P11C, R11C . . . . . . . . . . . . . . . . . . . . .224 BS 88 British Standard low voltage fuses AAO, AC, AD, BAO, BC, BD, CD, CEO, DD, DEO, ED, EF, EFS, ESD, FF, FG, GF, GG, GH, NITD, NSD, OSD, SSD, STD . . . . . . . . . . . . . . . . . . . . . . .225-226 DIN Type D and Neozed low voltage fuses D16, D27, D33, D125, NZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227 NH HRC Fuse links & bases NHG . . . . . . . . . . . . . . . . . . . . .228-231 Class gG/gL IEC 60 269 fuses C08G, C08M, C10G, C10M, C14G, C14M, C22G, C22M . . . . . . . . . . . . . . . . . . . . . .232-234 HRC Fuse holders CAMaster, SAFEloc . . . . . . . . . . . . . . . . . . . . .235 Quik-SpecTM Electrical Gear . . . . . . . . . . . . . . .237-247 Quik-SpecTM Coordination Panelboards . . . . . . . . . . . . . . . .238-239 Quik-SpecTM Power ModuleTM Elevator Disconnect Switches & Panels PS, PMP . . . . . . . . . . . . . . . . . . . . . .240-241 Quik-SpecTM DC Safety Switches BD . . . . . . . . . . . . . . . . . . . . .242 Quik-SpecTM Solar Combiner Boxes . . . . . . . . . . . . . . . . . .243-244 Quik-SpecTM AC Safety Switches CF . . . . . . . . . . . . . . . . . .245-246 HVAC Disconnects B221, B222 . . . . . . . . . . . . . . . . . . . . . . . . .247 Fuse Holders and Blocks . . . . . . . . . . . . . . . . .249-291 Optima(R) - fuse holder module and disconnect switch . . . . . . . . .250 Optima fuse holder module . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251 Optima NG 3-pole overcurrent protection module . . . . . . . . .252-253 CH Series Class J global modular fuse holders CH . . . . . . . . . . . .254 Safety J Class J (finger-safe) fuse holder JT, JTN . . . . . . . . .255-256 CH Series Class CC, midget & metric global modular fuse holders CHCC, CHPV, CHM, CH08, CH14, CH22 . . . . . . . . . . . . . .257-258 SAMITM fuse covers SAMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259 Class H(K) and R fuse blocks - 250V . . . . . . . . . . . . . . . . . .260-262 Class H(K) and R fuse blocks - 600V . . . . . . . . . . . . . . . . . .263-265 Class J fuse blocks J600, JP . . . . . . . . . . . . . . . . . . . . . . .266-268 Class T fuse blocks - 300V . . . . . . . . . . . . . . . . . . . . . . . . .269-270 Class T fuse blocks - 600V . . . . . . . . . . . . . . . . . . . . . . . . .271-272 Add-on fuse blocks BCA, BMA . . . . . . . . . . . . . . . . . . . . . . . . . .273 Class CC, Type M and Class G fuse blocks BC, BCCM, BG, BM, G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .274 Modular fuse blocks BH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .275 Box cover units for plug fuses SCY, SKA, SOU, SOW, SOX, SOY, SRU, SRW, SRX, SRY, SSN, SSU, SSW, SSX, SSY, STY, . . . . . . . . . . .276 In-line fuse holders HFA, HFB, HHB, HHT, HM, HR, HRK . . . . .277-278 Tron(R) in-line fuse holders HEB, HEC, HEG, HEH, HEJ, HET, HEX, HEY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .279-280 Panel mounted fuse holders (including indicating) HJL, HK, HKP, HLD, HPC, HPD, HPF, HPG, HPM, HPS, HPS, HTB, HTC . . . . . . .281-287 Fuse blocks for 14" x 1 14" and 14" x 1" fuses . . . . . . . . . . . .288-289 4 Fuse Holders and Blocks (Continued) Fuse blocks for 1332" x 1 12" fuses . . . . . . . . . . . . . . . . . . . . . . . .290 Rail mount fuse blocks & holders . . . . . . . . . . . . . . . . . . . . . . . .291 Power Distribution Blocks . . . . . . . . . . . . . . . . . . . .293 Power Distribution Block Selection Chart . . . . . . . . . . . . . . . . . . .294 PDBFS Series finger-safe power distribution blocks . . . . . . . . . .295 PDB Series power distribution blocks . . . . . . . . . . . . . . . . . . . . .296 163 Series power terminal blocks . . . . . . . . . . . . . . . . . . . .297-298 Series 11675 & 11725 power terminal blocks . . . . . . . . . . . . . .299 Series 160, 162, 163 & 165 power terminal blocks . . . . . . . . . .299 Series 162, 163 & 165 power stud terminal blocks . . . . . . . . . . .300 Series 160, 162, 163 & 165 power splicer terminal blocks . . . . .300 Series 14002 (barrier) & 14004 (dead front) terminal blocks . . . .301 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . .303-324 Rail mount terminal and disconnect terminal blocks . . . . . . .304-308 Sectional terminal blocks . . . . . . . . . . . . . . . . . . . . . . . . . .309-310 Quick connect terminal blocks . . . . . . . . . . . . . . . . . . . . . . . . . .311 Series TB100, 200 and 300/345 double row terminal blocks 312-317 Marking options and covers for double row terminal blocks .318-319 Series TB400 double row terminal blocks . . . . . . . . . . . . . . . . . .320 Series KU double row terminal blocks . . . . . . . . . . . . . . . . . . . . .321 Standard, flat and raised terminal blocks . . . . . . . . . . . . . . .322-324 Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . .325-386 Compact Circuit Protector (CCP) fused disconnect switches .326-329 Fused, dead front disconnect switches . . . . . . . . . . . . . . . . . . . .329 Fusible Disconnect Switch Overview . . . . . . . . . . . . . . . . . . . . . .330 30A Base & DIN rail mount fusible disconnect switches . . . .331-333 60-100A Base & DIN rail mount fusible disconnect switches 334-336 200A Base & DIN rail mount fusible disconnect switches . . .337-339 400-800A Base & DIN rail mount fusible disconnect switches . .340-343 30-400A Side operated fusible disconnect switches . . . . . . . . . .344 30-100A Flange operated fusible disconnect switches . . . . . . . . .345 30-800A Cable operated fusible disconnect switches . . . . . . . . .346 UL/cULus & IEC Technical data for fusible disconnect switches . .347-349 Non-fusible Disconnect Switch Overview . . . . . . . . . . . . . . .350-351 16-100A Base & DIN rail mount non-fusible disconnect switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .352-355 16-100A Door mounted non-fusible disconnect switches . . .356-358 125A Non-fusible disconnect switches . . . . . . . . . . . . . . . .359-360 200A Non-fusible disconnect switches . . . . . . . . . . . . . . . .361-362 400A Non-fusible disconnect switches . . . . . . . . . . . . . . . .363-364 600-800A Non-fusible disconnect switches . . . . . . . . . . . . .365-366 1200-1350A Non-fusible disconnect switches . . . . . . . . . . .367-368 30-600A Side operated non-fused disconnects . . . . . . . . . . . . . .369 30-200A Flange operated non-fused disconnects . . . . . . . . . . . .370 30-200A Cable operated non-fused disconnects . . . . . . . . . . . . .371 UL/cULus & IEC Technical data for non-fusible disconnect switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .372-377 30-800A Enclosed fusible disconnect switches . . . . . . . . . .378-380 16-3150A Enclosed fusible disconnect switches . . . . . . . . .381-383 Technical data for enclosed non-fusible disconnect switches 384-386 For product Data Sheets, visit www.cooperbussmann.com/datasheets/ulcsa Circuit Protection Products for the Electrical Industry Table of Contents RED indicates NEW information Telpower(R) compact fused disconnect switch . . . . . . . . . . . . . . . .388 Telpower miniature fused disconnect switch . . . . . . . . . . . . . . . .389 Fused disconnect switches for TPA fuses . . . . . . . . . . . . . . .390-391 Fused disconnect switches for TPS fuses . . . . . . . . . . . . . . . . . .392 Fused disconnect switches . . . . . . . . . . . . . . . . . . . . . . . . .393-399 Telpower specialty fuses . . . . . . . . . . . . . . . . . . . . . . . . . . .400-401 Telpower high-current switch . . . . . . . . . . . . . . . . . . . . . . .400-401 Filtered terminal blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .402 Power feed through terminal blocks . . . . . . . . . . . . . . . . . . .403-404 Catalog Sections Page Low Voltage Low Voltage Branch Supplementary Electronic Fuses Circuit Fuses Telcom Protection Devices . . . . . . . . . . . . . . . .387-404 Low Voltage, Branch Circuit Rated Fuses . . . . . 11 Low Voltage Supplementary Fuses . . . . . . . . . . 43 Electronic - PC Board and Small Dimension Fuses . .Small . . . . . . . . . . . . . . . 57 Electronic - PC Board and Transient voltage surge protectors TVS . . . . . . . . . . . . . . . . . . . .406 Transient surge protection limiters TVSS . . . . . . . . . . . . . . . . . . .407 Medium Voltage Fuses Surge Protection Devices . . . . . . . . . . . . . . . . .405-407 Medium Voltage Fuses and Fuse Links . . . . . . . 71 High Speed Fuses Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .409 High Speed Fuses . . . . . . . . . . . . . . . . . . . . . 93 IEC & British Fuses Cooper Bussmann service kits and assortments . . . . . . . . . .410-412 Clip clamps and rail adapters (DIN & American) . . . . . . . . . . . . . .413 Spare fuse holders, pullers, testers and cabinets . . . . . . . . . . . . .414 Fuse reducers and dummy "neutrals" . . . . . . . . . . . . . . . . . . . . .415 IEC & British Standard Fuses . . . . . . . . . . . . . 217 Quik-SpecTM Electrical Gear . . . . . . . . . . . . . .237 Fuse Holders & Blocks Fuse Holders and Blocks . . . . . . . . . . . . . . . . 249 Power Distribution Blocks Power Distribution & Terminal Blocks . . . . . . . 293 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . 303 Competitive Fuse Cross Reference and Low-Peak(R) Upgrade . . . . . . . . . . . . . . . . .Inside back cover Disconnects . . . . . . . . . . . . . . . . . . . . . . . . 325 Disconnects Index by Part Number . . . . . . . . . . . . . . . . . . . .436-440 Wire Connection Products Engineering Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .418 OSCARTM 2.0 Compliance Software . . . . . . . . . . . . . . . . . .419-420 Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .421 Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .422 Custom Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .423 Application Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .424-434 Bussmann fuse technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . .424 Motor Circuit Branch Circuit Protection . . . . . . . . . . . . . . . . . . . .431 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .432-434 Out-of-Stock Substitutions/Upgrades . . . . . . . . . . . . . . . . . . . . . .434 Commercial & industrial fuse applications . . . . . . . . . . . . . . . . . .435 Quik-SpecTM Electrical Gear Services & Application Guide . . . . . . . . . . . . . . . . . .417 Telcom Protection Devices Telecom Protection Devices . . . . . . . . . . . . . 387 Surge Protection Devices Surge Protection Devices . . . . . . . . . . . . . . 405 Services & Accessories Application Guide Accessories . . . . . . . . . . . . . . . . . . . . . . . . 409 Services & Application Guide . . . . . . . . . . . . 417 For product Data Sheets, visit www.cooperbussmann.com/products/datasheet.asp 5 Circuit Protection Products for the Electrical Industry Selecting Circuit Protection The following fuse selection guides are based on the 2005 NEC(R) and provided fuse recommendations for the various applications listed. These are only suggestions. Final fuse selection should be performed only by qualified personnel able to fully assess an application's circuit protection requirements. If you need assistance in selecting a fuse for a particular application, call the Cooper Bussmann Application Engineering team. This team is staffed by degreed electrical engineers and available by phone for technical and application support Monday - Friday, 8:00 a.m. - 5:00 p.m. Central Time. Application Engineering can be reached via phone, fax or e-mail: * Phone: 636-527-1270 * Fax: 636-527-1607 * E-mail: fusetech@cooperindustries.com Ballasts Indoor Fluorescent Consult fixture manufacturer for size and type. All Other (Mercury, Sodium, etc.) Consult fixture manufacturer for size and type. Fuse & Holder Recommendations Fuse GLR GMF GRF Holder(s) HLR Fuse GLQ GMQ Holder(s) HLQ Fuse & Holder Recommendations Fuse BAF KTK FNM FNQ Holder(s) HPF HPS Fuse KTK-R FNQ-R LP-CC Holder(s) HPS-RR HPF-RR KTQ BBS HPS-L HPF-L Fuse SC 0-15 Holder(s) HPF-EE HPS-EE SC 20 HPF-JJ HPS-JJ SC 25-30 HPF-FF HPS-FF Fuse & Holder Recommendations Outdoor Mercury, Sodium, etc. Consult fixture manufacturer for size and type. Fuse BAF KTK FNM FNQ Holder(s) HEB HEX HPC-D Fuse KTK-R FNQ-R LP-CC Holder(s) HEY Capacitors (NEC(R) 460) Protected by Time-Delay Fuses. 150% to 175% of Full Load Current Protected by Non-Time-Delay Fuses. 250% to 300% of Full Load Current. On Load Side of Motor Running Overcurrent Device. 6 Fuse Recommendations Volts 0-250 0-600 0-600 Protection recommended as shown, but not required. For product Data Sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse(s) LPN-RK_SP, FRN-R LPS-RK_SP, FRS-R LPJ_SP, LP-CC, FNQ-R, TCF Fuse Recommendations Volts 0-250 0-300 0-600 0-600 0-600 Fuse(s) KTN-R, NON JJN KTS-R, NOS JKS, KTK-R JJS Circuit Protection Products for the Electrical Industry Selecting Circuit Protection Electric Heat (NEC(R) 424) Size at 125% or next size larger but in no case larger than 60 amps for each subdivided load. Electric Space Heating Fuse Recommendation Volts 0-250 0-300 0-480 0-600 0-600 0-600 Electric Boilers with Resistance Type Immersion Heating Elements in an ASME Rated and Stamped Vessel Size at 125% or next size larger but in no case larger than 150 amps for each subdivided load. Fuse(s) LPN-RK_SP FRN-R, NON JJN SC 25 to SC 60 LPS-RK_SP FRS-R, NOS JJS LPJ_SP, LP-CC FNQ-R, JKS, KTK-R, TCF, SC 12 to SC 20 Mains, Feeders, Branches (NEC(R) 430) Feeder Circuits (600A & Less) No Motor Load 100% of non-continuous load plus 125% of continuous load. Fuse Recommendations Volts 0-250 0-300 0-600 0-600 0-600 Combination Motor Loads and Other Loads Motor Loads 150%* of the FLA of largest motor (if there are two or more motors of same size, one is considered to be the largest) plus the sum of all the FLA for all other motors plus 100% of non-continuous, nonmotor load plus 125% of continuous, non-motor load. 150%* of the FLA of largest motor (if there are two or more motors of same size, one is considered to be the largest) plus the sum of all the FLA for all other motors. Fuse(s) LPN-RK_SP, FRN-R JJN LPS-RK_SP, FRS-R JJS LPJ_SP, LP-CC JKS, KTK-R, LPT Fuse Recommendations Volts 0-25O 0-600 0-600 Fuse(s) LPN-RK_SP, FRN-R LPS-RK_SP, FRS-R LPJ- SP, LP-CC *A max. of 175% (or the next standard size if 175% does not correspond to a standard size) is allowed for all but wound rotor and all dc motors. Main, Branch & Feeder Circuits (601-6000A) 150% to 225% of full load current of largest motor plus 100% of full load current of all other motors plus 125% of continuous nonmotor load plus 100% of non-continuous non-motor load. For product Data Sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Recommendation Volts 0-600 Fuse(s) KRP-C_SP 7 Circuit Protection Products for the Electrical Industry Selecting Circuit Protection Motor Loads (NEC(R) 430) Fuse Sized For: 600V & Less Protected by TimeDelay Fuses Backup Overload w/ Motor Starter & ShortCircuit Protection Fuse Recommendations 125% of motor FLA or next size larger. Volts 0-250 0-600 Fuse(s) FRN-R FRS-R Fuse Recommendations 130% of motor FLA or next size larger. Short-Circuit Only Protected by Non-Time Delay Fuses & all Class CC Fuses Short-Circuit Only 175%* of motor FLA or next size larger. (If 175% does not correspond to a standard size). If this will not allow motor to start, due to higher than normal inrush currents or longer than normal acceleration times (5 sec. or greater), fuse may be sized up to 225% or next size smaller. Max. of 300%* of motor FLA or next size larger (if 300% does not correspond to a standard size). If this will not allow motor to start due to higher than normal inrush currents or longer than normal acceleration times (5 sec. or greater), fuses through 600 amps may be sized up to 400% or next size smaller. Volts 0-250 0-600 Fuse Recommendations Volts 0-250 0-600 0-600 Compare the min. melting time-current characteristics of the fuses with the time-current characteristics of the overload relay curve. The size fuse which is selected should be such that short.circuit protection is provided by the fuse and overload protection is provided by the controller overload relays. Fuse(s) LPN-RK_SP, FRN-R LPS-RK_SP, FRS-R LPJ_SP, TCF Fuse Recommendations Volts 0-250 0-300 0-600 0-600 0-600 *150% for wound rotor and all DC motors. Above 600V Fuse(s) LPN-RK_SP LPS-RK_SP Fuse(s) KTN-R, NON JJN KTS-R, NOS JJS LP-CC, JKS, KTK-R, LPT Fuse Recommendations Volts 2400 4800 7200 Fuse(s) JCK, JCK-A, JCH JCL, JCL-A, JCG JCR, 7.2 WKMSJ Solenoids (Coils) Branch Circuit Fuses Fuse Recommendation Size at 125% or next size smaller. Volts 0-250 0-600 0-600 Supplementary Fuses Size at 125% or next size larger. Fuse Recommendation Volts 0-32 0-125 0-250 0-500 8 For product Data Sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse(s) Best: LPN-RK_SP FRN-R LPS-RK_SP FRS-R LPJ_SP, LP-CC FNQ-R, TCF Fuse(s) MDL 9-30A, FNM 20-30A MDA 25-30A, FNM 12-15A MDL 116-8A, MDA 210-20A, FNM 110-10A, MDQ 1100-7A FNQ 110-30A Circuit Protection Products for the Electrical Industry Selecting Circuit Protection Transformers 600V Nominal or Less (NEC(R) 450.3) Primary Protection Only Primary and Secondary Protection Note: Components on the secondary still need overcurrent protection Rated primary current less than 2 amps 125% or next size larger Max. 300% or next size smaller (See NEC(R) 430.72(C) for control circuit transformer maximum of 500% Rated primary current greater than or equal to 2 amps but less than 9 amps 125% or next size larger Max. 167% or next size smaller Rated primary current greater than or equal to 9 amps 125% or next size larger Max. of 125% or next larger* Rated secondary current less than 9 amps Without Thermal Overload Protection NEC(R) Maximums Optimum Protection A A Maximum Fuse Size Rated secondary current 9 amps or greater With Thermal Overload Protection Transformer Impedance of 6% or Less Rated secondary current less than 9 amps Rated secondary current 9 amps or greater Transformer Impedance of More Than 6% But Less Than 10% Rated secondary current less than 9 amps Rated secondary current 9 amps or greater B B C D C Primary and secondary fuses at 125% of primary and secondary FLA or next size larger D E E F F % of Primary FLA (or next FLA size smaller) A = 250% B = 250% C = 600% D = 600% E = 400% F = 400% % of Secondary FLA A = 167% or next size smaller B = 125% or next size larger* C = 167% or next size smaller D = 125% or next size larger* E = 167% or next size smaller F = 125% or next size larger* *When 125% of FLA corresponds to a standard rating, the next larger size is not permitted. Fuse Recommendations Volts 250V 600V Fuse(s) LPN-RK_SP, FRN-R KRP-C_SP, LPJ_SP, LPS-RK_SP, FNQ-R, FRS-R, TCF For product Data Sheets, visit www.cooperbussmann.com/datasheets/ulcsa 9 Circuit Protection Products for the Electrical Industry Selecting Circuit Protection Transformers Over 600V Nominal (NEC(R) 450.3) Supervised Installations Primary Protection Only Primary at code max. of 250% or next standard size if 250% does not correspond to a standard rating Primary and Secondary Protection Transformer Impedance Less Than or Equal to 6% Transformer Impedance Greater Than 6% But Less Than 10% Primary at code max. of 300% Primary at code max.of 300% Note: Components on the secondary still need overcurrent protection Secondary Over 600V Secondary at code max. of 250% Secondary 600V or Below Secondary at code max. of 250% Secondary Over 600V Secondary at code max. of 225% Secondary 600V or Below Secondary at code max. of 250% Fuse Recommendations Volts 250V 600V 2475V 2750V 2750/5500V 5500V 7200V Unsupervised Installations Transformer Impedance Less Than or Equal to 6% Transformer Impedance Greater Than 6% But Less Than 10% Primary at code max. of 300% or next standard size if 300% does not correspond to a standard rating Primary at code max. of 300% or next standard size if 300% does not correspond to a standard rating Secondary Over 600V Secondary at code max. of 250% or next standard size if 250% does not correspond to a standard rating Secondary 600V or Below Secondary at code max. of 125% or next standard size if 125% does not correspond to a standard rating Secondary Over 600V Secondary at code max. of 225% or next standard size if 225% does not correspond to a standard rating Secondary 600V or Below Secondary at code max. of 125% or next standard size if 125% does not correspond to a standard rating 8300V 15500V 17500V 24000V 36000V 38000V Fuse(s) LPN-RK_SP, FRN-R LPS-RK_SP, LPJ-_SP, KRP-C_SP, FRS-R, FNQ-R, TCF JCD JCX JCW MV05, 5.5 ABWNA, 5.5 AMWNA, 5.5 FFN 7.2 AMWNA, 7.2 TDLSJ, 7.2 TFLSJ JCZ, JDZ, 8.25 FFN MV155, 15.5 CAVH 17.5 CAV, 17.5 TDM 24 TDM, 24 TFM, 24 FFM 36 CAV, 36 TDQ, 36 TFQ 38 CAV Solid State Devices (Diodes, SCRs, Triacs, Transistors) Short-Circuit Protection Only Fuse Recommendations "F," "S," "K," & 170M Series fuses sized up to several sizes larger than full load RMS or dc rating of device. Volts 0-130 0-250 0-500 0-600 0-700 0-1000 10 For product Data Sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse(s) FWA FWX FWH FWC, KAC, KBC FWP, 170M Series, SPP FWJ, 170M Series, SPJ Low Voltage, Branch Circuit Rated Fuses Page 12-14 15-16 Class Fuses Volts CC . . . . . . LP-CC . . . . . . . . . . . . . . . 600V . . . . . 17 FNQ-R . . . . . . . . . . . . . . . KTK-R . . . . . . . . . . . . . . . 600V . . . . . 600V . . . . . 18 19 600V . . . . . 20-21 CF . . . . . . . TCF* & TCFH_N . . . . . . . . . Low Voltage Branch Circuit Fuses Fuse Holder & Block Selection Guide Class Fuse Dimensions Fuses By Fuse Class *Class J performance G....... SC . . . . . . . . . . . . . . . . . . 600/480V . . 22 J....... LPJ-_SP . . . . . . . . . . . . LPJ-_SPI Indicator . . . . . JKS . . . . . . . . . . . . . . . . . 600V . . . . . 600V . . . . . 600V . . . . . 23 23 24 K5 & H . . . NON . . . . . . . . . . . . . . . . NOS . . . . . . . . . . . . . . . . 250V . . . . . 600V . . . . . 25 25 L....... KRP-C_SP . . . . . . . . . . . . KRP-CL . . . . . . . . . . . . . . KLU . . . . . . . . . . . . . . . . . KTU . . . . . . . . . . . . . . . . . 600V . . . . . 26-27 600V . . . . . 27 600V . . . . . 28 600V . . . . . 28 RK1 . . . . . LPN-RK_SP . . . . . . . . . . . LPN-RK_SPI Indicator . . . LPS-RK_SP . . . . . . . . . . . LPS-RK_SPI Indicator . . . KTN-R . . . . . . . . . . . . . . . KWS-R . . . . . . . . . . . . . . . 250V . . . . . 250V . . . . . 600V . . . . . 600V . . . . . 250V . . . . . 600V . . . . . 29-31 29-31 29-31 29-31 32 33 RK5 . . . . . DLN-R . . . . . . . . . . . . . . . DLS-R . . . . . . . . . . . . . . . FRN-R . . . . . . . . . . . . . . . FRS-R . . . . . . . . . . . . . . . PVS-R . . . . . . . . . . . . . . . 250V . . . . . 600V . . . . . 250V . . . . . 600V . . . . . 600V . . . . . 34 34 35 36 37 T....... JJN . . . . . . . . . . . . . . . . . JJS . . . . . . . . . . . . . . . . . 300V . . . . . 600V . . . . . 38 39 Plug Fuses W, SL, TL, S, T, P, TC Series & MB Edison Base Circuit Breakers, SA . . . . . . . . . . . 125V . . . . . 40-42 RED indicates NEW information 11 Low Voltage, Branch Circuit Rated Fuses Holders & Blocks For Branch Circuit Rated Fuses Class Fuses Volts CC LP-CC FNQ-R KTK-R 600V . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . Page 17 18 19 Holders * * * * * * OPM-NG-SC3 3-pole, panel/DIN rail mount . . . . . . . . . . . . OPM-1038R 3-pole, panel/DIN rail mount . . . . . . . . . . . . . OPM-1038RSW 3-pole w/ switch, panel/DIN rail mount . . CHCC_D 1 to 3-pole, DIN rail mount . . . . . . . . . . . . . . . . . HPF-RR, front panel mount . . . . . . . . . . . . . . . . . . . . . . . HPS-RR, front panel mount . . . . . . . . . . . . . . . . . . . . . . . 252 251 250 257 286 286 OPM-1038R & OPM-1038RSW OPM-NG-SC3 CHCC_D Blocks * BC Series, panel mount . . . . . . . . . . . . . . . . . . . . . . . . . . 274 Disconnects * CDF30J3 fusible disconnect switches. . . . . . . . . . . . . . . . . * FD400J3 fusible disconnect switches . . . . . . . . . . . . . . . . . 330 340 HPF-RR HPS-RR BC Series FD400J3 CFD30J3 EFJ30X-3PB6 Class Fuses Volts G SC 600/480V . . . . . . . . . . . . . . . . . Page 22 Holders * HP Series front panel accessible, front panel mount . . . . . 286 Blocks * BG Series, panel/DIN rail with adapters . . . . . . . . . . . . . . * G Series, panel/DIN rail with adapters . . . . . . . . . . . . . . . HP Series 274 274 Class Fuses Volts K5 & H NON NOS 250V . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . BG & G Series Page 25 25 Blocks * Modular Type Fuse Blocks 250/600V, panel mount . . . . . . * H250 Series 1 to 3-pole 250V, panel mount . . . . . . . . . . . . * H600 Series 1 to 3-pole 600V, panel mount . . . . . . . . . . . 275 260 263 Modular Type H250 Series H600 Series 12 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage, Branch Circuit Rated Fuses Holders & Blocks For Branch Circuit Rated Fuses Fuses Volts L KRP-C_SP KRP-CL KLU KTU 600V . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . Page Low Voltage Branch Circuit Fuses Class 26 27 28 28 Blocks * 51215 1-pole, panel mount* * 51235 3-pole, panel mount* FD400J3 *Call our customer satisfaction team at 636-527-3877 for more information. 51235 51215 Disconnects * FD800L3 fusible disconnect switches . . . . . . . . . . . . . . . . . 340 Class Fuses Volts RK1 LPN-RK_SP LPS-RK_SP KTN-R KWS-R 250V . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . Page 29 29 32 33 Blocks * R250 Series 1- to 3-pole 250V, panel mount . . . . . . . . . . . . * R600 Series 1- to 3-pole 600V, panel mount . . . . . . . . . . . . 260 263 Class Fuses Volts RK5 DLN-R DLS-R FRN-R FRS-R 250V . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . 34 34 35 36 * R250 Series 1- to 3-pole 250V, panel mount . . . . . . . . . . . . * R600 Series 1- to 3-pole 600V, panel mount . . . . . . . . . . . . 260 263 R250 Series R600 Series Page Blocks Class Fuses Volts T JJN JJS 300V . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . R600 Series R250 Series Page 38 39 Blocks * BH Series modular-style, panel mount (<60A) . . . . . . . . . . * T300 Series 1 to 4-pole 300V, panel mount . . . . . . . . . . . . * T600 Series 1 to 3-pole 600V, panel mount . . . . . . . . . . . . 275 269 271 BH Series Disconnects * CDF30J3 fusible disconnect switches. . . . . . . . . . . . . . . . . * FD400J3 fusible disconnect switches . . . . . . . . . . . . . . . . . T300 Series T600 Series 330 340 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 13 Low Voltage, Branch Circuit Rated Fuses Holders & Blocks For Branch Circuit Rated Fuses Class Fuses Volts J, CF TCF* LPJ-SP JKS 600V . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . Page 20 23 24 *Class J performance Holders * TCFH CUBEFuseTM holder, panel/DIN rail mount . . . . . . . * CH Series Class J modular 1- to 3-pole, panel/ DIN rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . * Safety JTM Series modular holders, panel/DIN rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21 TCFH CH Series Safety JTM Series Modular Type 254 255 Blocks * * * * Modular Type Fuse Blocks 600V, panel mount . . . . . . . . . . J600 Series, panel mount . . . . . . . . . . . . . . . . . . . . . . . . . JP Series pyramid blocks, panel mount . . . . . . . . . . . . . . . BH Series modular-style open blocks, panel mount . . . . . 275 266 267 275 J600 Series JP Series BH Series Disconnects Disconnects * CDF30J3 fusible disconnect switches. . . . . . . . . . . . . . . . . * FD400J3 fusible disconnect switches . . . . . . . . . . . . . . . . . 330 340 FD400J3 CFD30J3 Class Fuses Volts Plug Fuses W, SL, TL, S, T, P and TC Series 125V . . . . . . . . . . . . . . . . . . 40-41 Box Cover Units * Standard electrical box mounting . . . . . . . . . . . . . . . . . . . 276 Page Fuse Only Fuse Reducers For Class R Fuses 250V Equipment Desired Fuse Fuse Clip Amps (Case) Amp Size 60 100 200 400 600 30 30 60 60 100 100 200 100 200 400 *Single reducer only (pair not required). 14 EFJ30X-3PB6 Catalog No. (Pairs) 250V NO.263-R NO.213-R NO.216-R NO.226-R NO.2621-R NO.2641-R NO.242-R NO.2661-R NO.2662-R NO.2664-R* With Grounded Outlet With Switch Fuse Reducers For Class R Fuses 600V Equipment Desired Fuse Fuse Clip Amps (Case) Amp Size 60 100 200 400 600 30 30 60 60 100 100 200 100 200 400 *Single reducer only (pair not required). For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Catalog No. (Pairs) 600V NO.663-R NO.216-R NO.616-R NO.626-R NO.2621-R NO.2641-R NO.642-R NO.2661-R NO.2662-R NO.2664-R* Low Voltage, Branch Circuit Rated Fuses Branch Circuit Rated Fuse Dimensions Low Voltage Branch Circuit Fuses Class J Dimensions - in (mm) Low-Peak(R) and Limitron(R) Fuses LPJ & JKS -- 600V Amp Range A B 1-30 2.25 (57.2) 0.81 (20.6) -- C -- D 0.50 (12.7) E -- -- -- -- 35-60 2.38 (60.3) 1.06 (27.0) -- -- 0.63 (15.9) -- -- -- -- 65-100 4.63 (117.5) 1.13 (28.6) 3.63 (92.1) 2.63 (66.7) 1.00 (25.4) 0.75 (28.6) 0.13 (3.2) 0.41 (10.4) 0.28 (7.1) 110-200 5.75 (146.1) 1.63 (41.4) 4.38 (111.1) 3.00 (76.2) 1.38 (34.9) 1.13 (28.6) 0.19 (4.8) 0.38 (9.5) 0.28 (7.1) 225-400 7.12 (181.0) 2.11 (53.6) 5.25 (133.3) 3.26 (82.8) 1.87 (47.6) 1.62 (41.2) 0.25 (6.4) 0.56 (14.2) 0.40 (10.3) 450-600 8.00 (203.2) 2.60 (66.0) 6.00 (152.4) 3.31 (84.0) 2.12 (54.0) 2.00 (50.8) 0.53 (13.5) 0.72 (18.3) 0.53 (13.5) G A C D A E F B H 1A to 60A I F E H I B G 65A to 600A Class CC Dimensions - in (mm) 1.5" (0.031) (38.1mm) 0.41" (0.005) (10.3mm) Class RK1 & RK5 Dimensions - in (mm) Basic dimensions are same as Class H (formerly NEC) One-Time (NON & NOS) and Superlag Renewable RES & REN fuses. NOTE: These fuses can be used to replace existing Class H, RK1 and RK5 fuses relating to dimensional compatibility. Ferrule Styles Amp Range 250V A 600V A B B 1 10-30 2 (50.8) 0.56 (14.3) 5.0 (127.0) 0.81 (20.6) 35-60 3 (76.2) 0.81 (20.6) 5.5 (139.7) 1.06 (27.0) A B Fusetron(R) -- (FRN-R & FRS-R)& Limitron(R) -- (KTN-R & KTS-R) Amp Range 250V A B 600V A B 70-100 5.88 (149.2) 1.06 (26.9) 7.88 (200.0) 1.34 (34.0) 110-200 7.13 (181.0) 1.56 (39.6) 9.63 (244.5) 1.84 (46.7) 225-400 8.63 (219.1) 2.38 (60.5) 11.63 (295.3) 2.59 (65.8) 450-600 10.38 (263.5) 2.88 (73.2) 13.38 (339.7) 3.13 (79.5) B 600V A B 7.88 (200.0) 1.16 (29.5) A B Low-Peak(R) -- (LPN-RK & LPS-RK) 15 Amp Range 250V A 70-100 5.88 (149.2) 1.16 (29.5) 110-200 7.13 (181.0) 1.66 (42.2) 9.63 (244.5) 1.66 (42.2) 225-400 8.63 (219.1) 2.38 (60.5) 11.63 (295.3) 2.38 (60.5) 450-600 10.38 (263.5) 2.88 (73.2) 13.38 (339.7) 2.88 (73.2) For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa A B 15 Low Voltage, Branch Circuit Rated Fuses Branch Circuit Rated Fuse Dimensions Class L Dimensions - in (mm) Low-Peak(R) and Limitron(R) Fuses Amp Range A B C1 C2 D F G I J1 J2 J3 J4 601-800 8.63 (219.1) 2.40 (61.0) 6.75 (171.5) 5.75 (146.1) 3.75 (95.3) 2.00 (50.8) 0.38 (9.5) 0.63 (15.9) -- -- -- -- 801-1200 10.75 (273.1) 2.40 (61.0) 6.75 (171.5) 5.75 (146.1) 3.75 (95.3) 2.00 (50.8) 0.38 (9.5) 0.63 (15.9) -- -- -- -- 1350-1600 10.75 (273.1) 3.00 (76.2) 6.75 (171.5) 5.75 (146.1) 3.75 (95.3) 2.38 (60.3) 0.44 (11.1) 0.63 (15.9) -- -- -- -- 1800-2000 10.75 (273.1) 3.50 (88.9) 6.75 (171.5) 5.75 (146.1) 3.75 (95.3) 2.75 (69.9) 0.50 (12.7) 0.63 (15.9) -- -- -- -- 2001-2500 10.75 (273.1) 4.80 (122.0) 6.75 (171.5) 5.75 (146.1) 3.75 (95.3) 3.50 (88.9) 0.75 (19.1) 0.63 (15.9) 1.75 (44.5) 1.38 (34.9) 0.88 (22.2) 0.81 (20.6) 3000 10.75 (273.1) 5.00 (127.0) 6.75 (171.5) 5.75 (146.1) 3.75 (95.3) 4.00 (101.6) 0.75 (19.1) 0.63 (15.9) 1.75 (44.5) 1.38 (34.9) 0.88 (22.2) 0.81 (20.6) 3500-4000 10.75 (273.1) 5.75 (146.1) 6.75 (171.5) 5.75 (146.1) 3.75 (95.3) 4.75 (120.7) 0.75 (19.1) 0.63 (15.9) 1.75 (44.5) 1.38 (34.9) 1.63 (41.3) 0.88 (22.2) 4500-5000 10.75 (273.1) 6.25 (158.8) 6.75 (171.5) 5.75 (146.1) 3.75 (95.3) 5.25 (133.4) 1.00 (25.4) 0.63 (15.9) 1.75 (44.5) 1.38 (34.9) 1.63 (41.3) 0.88 (22.2) 6000 10.75 (273.1) 7.13 (181.0) 6.75 (171.5) 5.75 (146.1) 3.75 (95.3) 5.75 (146.1) 1.00 (25.4) 0.63 (15.9) 1.75 (44.5) 1.38 (34.9) 1.63 (41.3) 0.88 (22.2) NOTE: KRP-CL (150A to 600A) fuses have same dimensions as 601-800A case size. KTU (200-600A) have same dimensions, except tube 3" length x 2" diameter (76.2 x 50.8mm); terminal 158" width x 114" thick (41.3 x 31.8mm). J3 J3 J2 J1 J4 C1 C2 J4 I 801A to 2000A A A 601A to 800A All Slots and Holes J2 J1 2001A to 3000A 3500A to 4000A 4500A to 6000A G D F B Class T Dimensions - in (mm) T-Tron(R) Fuses JJN -- 300V Amp Range A B C D 1-30 0.88 (22.2) 0.41 (10.3) -- -- 35-60 0.88 (22.2) 0.56 (14.3) -- -- 70-100 2.16 (54.8) 0.75 (19.1) 1.56 (39.7) 0.84 (21.4) 110-200 2.44 (61.9) 0.88 (22.2) 1.69 (42.9) 0.84( 21.4) 225-400 2.75 (69.9) 1.00 (25.4) 1.84 (46.8) 0.86 (21.8) 450-600 3.06 (77.8) 1.25 (31.8) 2.03 (51.6) 0.88 (22.2) 601-800 3.38 (85.7) 1.75 (44.5) 2.22 (56.4) 0.89 (22.6) 801-1200 4.00 (101.6) 2.00 (50.8) 2.53 (64.3) 1.08 (27.4) JJN 70A to 1200A JJS 70A to 800A JJS -- 600V Amp Range A B C D 1-30 1.50 (14.3) 0.56 (38.1) -- -- 35-60 1.56 (20.6) 0.81 (39.7) -- -- 70-100 2.95 (19.1) 0.75 (75.0) 2..36 (59.9) 1.64 (41.7) 110-200 3.25 (22.2) 0.88 (82.6) 2.50 (63.5) 1.66 (42.1) 225-400 3.63 (25.4) 1.00 (92.1) 2.72 (69.1) 1.73 (44.1) 450-600 3.98 (31.8) 1.25 (101.2) 2.96 (75.0) 1.78 (45.2) 601-800 4.33 (44.5) 1.75 (109.9) 3.17 (80.6) 1.88 (47.6) 16 JJS 35A to 60A For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 16 Low Voltage, Branch Circuit Rated Fuses Low-Peak(R) Time-delay, Rejection-Type Fuses LP-CC-3-12 LP-CC-12 LP-CC-1-14 LP-CC-4 LP-CC-15 LP-CC-1-410 LP-CC-4-12 LP-CC-20 LP-CC-1- 2 LP-CC-5 LP-CC-25 LP-CC-1-610 LP-CC-5-610 LP-CC-30 LP-CC-1-8 10 LP-CC-6 LP-CC-2 LP-CC-6-14 LP-CC-2-14 LP-CC-7 1 20 25 30 3 3/TM 4 4/TM 6 8 10 12 15 /TM fl/ / 1 1/ 1000 100 10 1 AMP RATING 30 25 20 15 1,000 800 600 500 400 2-8/10 300 1-1/4 200 100 80 60 50 40 30 20 TIME IN SECONDS 10 2,000 LP-CC-10 LP-CC-1- 8 1 2,000 800 1,000 LP-CC-3-810 LP-CC-1 3,000 400 500 600 LP-CC-9 4,000 300 LP-CC-3 Current Limitation Curves 200 LP-CC-810 CURRENT IN AMPS 80 100 LP-CC-8 .01 40 50 60 LP-CC-7 2 LP-CC-2-810 .1 30 LP-CC-2- 2 LP-CC-610 1 1 20 LP-CC- 2 1 10 10 Typical Applications * Specialized Circuits * Industrial Control * Isolated, In-Line Fuse Holder Catalog Numbers (Amps) 100 .4 Features and Benefits * Time delay coupled with Class CC current-limiting response provides close sizing on small motor and relay circuits, and maximum component short-circuit current rating protection. * 200kA interrupting rating provides high ratings for control circuit locations. * Class CC rejection feature, with appropriate fuse block, prevents inserting lesser-rated supplementary fuses. * Inventory consolidation of 1332 x 1 12 inch supplementary fuses reduces SKU investment and minimizes potential for misapplying fuse. * Selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit. AMP RATING 200 INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS Specifications Description: Time-delay, current-limiting, rejection-type fuse - 12 seconds (minimum) at 200% rated amps. Dimensions: 1332" x 1 12" (10.3 x 38.1mm). Ratings: Volts -- 600Vac (or less) -- 300Vdc (12-2810A & 20-30A) -- 150Vdc (3-15A) Amps -- 12-30A IR -- 200kA RMS Sym. -- 20kA DC Agency Information: CE, Std. 248-4, Class CC, UL Listed, Guide JDDZ, File E4273, CSA Certified; Class 1422-02, File 53787. 1 Low Voltage Branch Circuit Fuses Time Current Characteristics--Average Melt LP-CC Class CC PROSPECTIVE SHORT-CIRCUIT CURRENT-SYMMETRICAL RMS AMPS Recommended Fuse Holders & Blocks For Class CC Fuses * See page 12 Data Sheet: 1023 17 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 17 Low Voltage, Branch Circuit Rated Fuses CC-Tron(R) Rejection-type Fuses Features and Benefits * Time delay compatible with inrush characteristic of small control transformers. * Current limitation at Class CC levels provides maximum component short-circuit current rating protection. * 200kA interrupting rating provides high ratings for control circuit locations. * Class CC rejection feature, with appropriate fuse block, prevents inserting lesser-rated supplementary fuses. Typical Applications * Line Protection, Small Control Transformers * Industrial Control * Isolated, In-Line Fuse Holders Catalog Numbers (Amps) FNQ-R-7-1/2 FNQ-R-5 FNQ-R-3 FNQ-R-1 10 1 FNQ-R-7 FNQ-R-12 FNQ-R-2-14 FNQ-R-7-12 FNQ-R-610 FNQ-R-2-12 FNQ-R-8 FNQ-R- 4 FNQ-R-2-810 FNQ-R-9 FNQ-R-810 FQN-R-3 FNQ-R-10 FNQ-R-1 FNQ-R-3-210 FNQ-R-12 FNQ-R-1-18 FNQ-R-3-12 FNQ-R-15 FNQ-R-1-14 FNQ-R-4 FNQ-R-17-12 FNQ-R-1-310 FNQ-R-4-12 FNQ-R-20 FNQ-R-1-410 FNQ-R-5 FNQ-R-25 FNQ-R-1-12 FNQ-R-5-610 FNQ-R-30 0.01 200 FNQ-R-6-14 FNQ-R-2 300 400 500 FNQ-R-1-810 FNQ-R-410 100 FNQ-R-310 10 FNQ-R-6 0.08 FNQ-R-1-610 1 0.01 FNQ-R-14 3 AMP RATING 100 TIME IN SECONDS Specifications Description: Time-delay, branch circuit, rejection-type fuse. Dimensions: 1332" x 1 12" (10.3 x 38.1mm). Ratings: Volts -- 600Vac (or less); 300Vdc (15-20A) Amps -- 14-30A IR -- 200kA RMS Sym.; 20kA DC Agency Information: CE, Std. 248-4, Class CC, UL Listed, Guide JDDZ, File E4273 CSA Certified, Class 1422-01, File 53787. FNQ-R-1/2 Time-Current Characteristic Curves--Average Melt FNQ-R Class CC CURRENT IN AMPS For superior electrical protection, Cooper Bussmann recommends upgrading FNQ-R fuse applications to Low-Peak LP-CC fuses See page 17. Recommended Fuse Holders & Blocks For Class CC 600V Fuses Data Sheet: 1014 18 * See page 12 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 18 Low Voltage, Branch Circuit Rated Fuses Limitron(R) Rejection-type Fuses Branch Circuit Fuses Time-Current Characteristic Curves--Average Melt KTK-R Class CC Specifications Description: Fast-acting, branch circuit, rejection-type fuse. Dimensions: 1332" x 1 12" (10.3 x 38.1mm). Ratings: Volts -- 600Vac (or less) Amps -- 110-30A IR -- 200kA RMS Sym. Agency Information: CE, Std. 248-4, Class CC, UL Listed, Guide JDDZ, File E4273 CSA Certified, File 53787, Class 1422-02. Features and Benefits * Current limitation at Class CC levels provides maximum component short-circuit current protection. * 200kA interrupting rating provides high ratings for control circuit locations. * Class CC rejection feature, with appropriate fuse block, prevents inserting lesser-rated supplementary fuses. Typical Applications * Specialized Circuits * Industrial Control * Isolated, In-Line Fuse Holders (street lighting) Catalog Numbers (Amps) KTK-R-110 KTK-R-1 KTK-R-18 KTK-R-1-12 KTK-R-7 KTK-R-8 KTK-R-210 KTK-R-2 KTK-R-9 KTK-R-14 KTK-R-2-12 KTK-R-10 KTK-R-310 KTK-R-3 KTK-R-12 KTK-R-410 KTK-R-3-12 KTK-R-15 KTK-R-12 KTK-R-4 KTK-R-20 KTK-R-610 KTK-R-5 KTK-R-25 KTK-R-34 KTK-R-6 KTK-R-30 For superior electrical protection, Cooper Bussmann recommends upgrading KTK-R fuse applications to Low-Peak LP-CC fuses See page 17. Recommended Fuse Holders & Blocks For Class CC Fuses * See page 12 Data Sheet: 1015 19 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 19 Low Voltage, Branch Circuit Rated Fuses CUBEFuse(R) Finger-safe Fuse and Fuse Holder System TCF & TCF_RN (fuse) Class CF TCFH_N (holder) Available With Indication Fuse Catalog Numbers Indicating (Amps) TCF6 TCF25 TCF50 TCF10 TCF30 TCF60 TCF15 TCF35 TCF70 TCF17- 2 TCF40 TCF80 TCF20 TCF45 TCF90 1 TCF100 Fuse Catalog Numbers Non-Indicating (Amps) Specifications Description: Finger-safe fuse and fuse holder system; dualelement, time-delay fuse; 10 seconds minimum operating time at 500% rated amps. Dimensions: See Dimensions illustration. Poles: 1-pole (gangable) Ratings: Volts -- 600Vac (or less) -- 300Vdc (or less) Amps -- 1-100A IR -- 300kA RMS Sym. (UL) -- 200kA RMS Sym. (CSA) -- 100kA DC (UL & CSA) Agency Information: CE, UL Listed Guide JFHR, File E4273, CSA Certified Fuse: Class 1422- 02, File 53787, UL Listed Fuse holder: Guide IZND, File E214079, CSA Certified Fuse holder: Class 6225-01, File 47235. TCF1RN TCF17-12RN TCF40RN TCF80RN TCF3RN TCF20RN TCF45RN TCF90RN TCF6RN TCF25RN TCF50RN TCF100RN TCF10RN TCF30RN TCF60RN TCF15RN TCF35RN TCF70RN Fuse Holder Catalog Numbers Catalog Numbers Amp Range Wire Range* Single Wire Dual Wire TCFH30N 1-30 14 to 8 AWG Cu 18 to 10 AWG TCFH60N 1-60 14 to 4 AWG Cu 10 to 6 AWG Cu TCFH100N 1-100 10 to 1 AWG Cu 6 AWG Cu *75C minimum Cu wire only. Time-Current Characteristic Curves-Average Melt Features and Benefits * Separate overload and short-circuit elements provide time delay for sizing of high inrush loads linked with Class J current limitation. * Selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit. * Smallest footprint of any Class CC, J, T or RK fuse provides substantial space savings and installation flexibility. * IEC 60529 and finger-safe rating provides enhanced workplace safety. Typical Applications * Electrical Panelboards * Machinery Disconnects * Industrial Control * Required Finger-Safe Systems Data Sheet: 9000 (fuses) and 9007 (holders) 20 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 20 Low Voltage, Branch Circuit Rated Fuses CUBEFuse(R) Finger-safe Fuse and Fuse Holder System Fuse Amps A 1.88 1-15 (47.75) 1.88 17.5-20 (47.75) 1.88 25-30 (47.75) 2.13 35-40 (54.10) 2.13 45-50 (54.10) 2.13 60 (54.10) 3.01 70-100 (76.45) Holder TCFH30N TCFH60N TCFH100N B 0.75 (19.05) 0.75) (19.05) 0.75 (19.05) 1.00 (25.40) 1.00 (25.40) 1.00 (25.40) 1.00 (25.40) Dimensions - in (mm) C D E 1.00 0.23 0.04 (25.40) (5.84) (1.02) 1.00 0.27 0.04 (25.40) (6.86) (1.02) 1.00 0.31 0.04 (25.40) (7.94) (1.02) 1.13 0.36 0.04 (28.58) (9.14) (1.02) 1.13 0.40 0.04 (28.58) (10.16) (1.02) 1.13 0.44 0.04 (28.58) (11.11) (1.02) 1.26 0.57 0.06 (32.00) (14.4) (1.60) F 0.63 (15.88) 0.63 (15.88) 0.63 (15.88) 0.63 (15.88) 0.63 (15.88) 0.63 (15.88) 0.63 (15.88) G 0.27 (6.86) 0.27 (6.86) 0.27 (6.86) 0.38 (9.65) 0.38 (9.65) 0.38 (9.65) 0.39 (9.93) H I J K L M 2.30 (58.50) 2.60 (66.12) 2.91 (73.81) 0.76 (19.37) 1.03 (26.23) 1.05 (26.74) 1.357 (34.24) 1.60 (40.64) 2.01 (50.93) 0.15 (3.76) 0.17 (4.34) 0.15 (3.81) 0.80 (20.39) 2.51 (63.65) Current Limitation Curves Data Sheet: 9000 (fuses) and 9007 (holders) 21 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 21 Low Voltage Branch Circuit Fuses Dimensions for CUBEFuse(R) Fuse and Fuse Holder Low Voltage, Branch Circuit Rated Fuses Time-delay Fuses Time-Current Characteristic Curves--Average Melt SC Class G Specifications Description: Fast-acting (12-6A), time-delay (7-60A)fuse. Dimensions: See dimensions illustration. Ratings: Volts -- 600Vac (12-20A) -- 480Vac (25-60A) -- 170Vdc (12-20A) -- 300Vdc (30 & 60A only) Amps -- 12-60A IR -- 100kA RMS Sym. -- 10kA DC Agency Information: CE, Std. 248-5, Class G, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-01, File 53787. Features and Benefits * Current limiting for component protection, providing Class G energy-limitation for branch circuit protection. * 100kA interrupting rating provides cost-effective branch pcircuit fusing. * Variations in length help prevent overfusing. Typical Applications * Fusible Branch Panelboards * HVAC Branch Circuit Protection Catalog Numbers (Amps) SC-10 SC-25 SC-7 SC-12 SC-30 SC-45 SC-50 SC-1-12 SC-4 SC-8 SC-15 SC-35 SC-60 SC-2 SC-5 SC-9 SC-20 SC-40 Current Limitation Curves B 10,000 Diameter 1.31 (33.3) 0.41" (10.4) SC-20 1.41 (35.8) 0.41" (10.4) A SC-25 to -30 1.62 (41.2) 0.41" (10.4) (Length) SC-35 to -60 2.25 (57.1) 0.41" (10.4) 0.41" (10.3mm) AMP RATING Length SC-12 to -15 1,000 A 100 1,000 Fuse Amps 30 20 15 100 Dimensions -in (mm) 60 100,000 SC-6 SC-3 10,000 SC-2-12 SC-1 INSTANTANEOUS PEAK LET -THROUGH CURRENT IN AMPS SC-12 RMS SYMMETRICAL CURRENTS IN AMPS A-B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) Recommended Fuse Holders & Blocks For Class G Fuses Data Sheet: 1024 22 * See page 12 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage, Branch Circuit Rated Fuses Low-Peak(R) Dual-element, Time-delay Fuses 600A 400A 125A 200A 250A 60A 80A 100A 30A 15A 10A 200 LPJ-5-610SP LPJ-35SP** LPJ-175SP** LPJ-1-810SP LPJ-6SP** LPJ-40SP** LPJ-200SP** LPJ-2SP LPJ-7SP** LPJ-45SP** LPJ-225SP** LPJ-2-14SP LPJ-8SP** LPJ-50SP** LPJ-250SP** LPJ-2-12SP LPJ-9SP** LPJ-60SP** LPJ-300SP** LPJ-2-810SP LPJ-10SP** LPJ-70SP** LPJ-350SP** LPJ-3SP LPJ-12SP** LPJ-80SP** LPJ-400SP** LPJ-3-210SP LPJ-15SP** LPJ-90SP** LPJ-450SP** LPJ-3-12SP LPJ-17-12SP** LPJ-100SP** LPJ-500SP** LPJ-4SP LPJ-20SP** LPJ-110SP** LPJ-600SP** TIME IN SECONDS 10,000 1,000 100 10 1 LPJ Current Limitation Curves B 100,000 600A 400A 200A 100A 60A 10,000 30A 15A AMP RATING LPJ-1-610SP Current Limitation Curves 1,000 A 100 200,000 LPJ-150SP** CURRENT IN AMPS 300,000 LPJ-30SP** .01 100,000 LPJ-125SP** LPJ-5SP .1 10,000 LPJ-25SP** LPJ-1- 4SP 1 1,000 LPJ-4-12SP 10 100 Features and Benefits * Separate overload and short-circuit elements provide time delay for sizing of high inrush loads linked with Class J current limitation. * Selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit. * Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer. Typical Applications * Power Panelboards * Branch Circuit Breaker Panelboard Mains * Machinery Disconnects * Industrial Control Catalog Numbers (Amps) 100 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS Specifications Description: Dual-element, time-delay fuse; 10 seconds (minimum) at 500% rated amps. Now available with optional indication on select ratings (see Catalog Numbers table). Dimensions: See page 11 for Class J dimensions. Ratings: Volts -- 600Vac (or less) -- 300Vdc (or less) Amps -- 1-600A IR -- 300kA RMS Sym. -- 100kA dc Agency Information: CE, UL Listed - Special Purpose*, Guide JFHR, File E56412, CSA Certified (200k AIR) Class J per CSA-22.2 No. 248.8, Class 1422-02, File 53787. 1 AMP RATING 300 Indication LPJ-1SP 6A 1A Available With 3A Time-Current Characteristic Curves-Average Melt PROSPECTIVE SHORT-CIRCUIT CURRENT SYMMETRICAL RMS AMPS *Meets all performance requirements of UL Standard 248-8 for Class J fuses. **Available with optional permanent replace fuse indication. To order, place "I" at end of catalog number. Example: LPJ-6SPI. Available with silver plated terminals. Add SP/ in front of Catalog Number. Recommended Fuse Holders & Blocks For Class J Fuses Data Sheets: 1006 (0-60) and 1007 (70-600) With indication 1062 (6-60) and 1063 (70-600) * See page 14 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 23 Low Voltage Branch Circuit Fuses LPJ_SP Class J Low Voltage, Branch Circuit Rated Fuses Limitron(R) Fast-acting Fuses 600A 400A 200A 100A 60A 300 30A Time-Current Characteristic Curves--Average Melt JKS Class J AMP RATING JKS 100 TIME IN SECONDS 10 Specifications Description: Fast-acting, current-limiting fuse. Dimensions: See page 15 for Class J dimensions. Ratings: Volts -- 600Vac (or less) Amps -- 1-600A IR -- 200kA RMS Sym. Agency Information: CE, Std. 248-8, Class J, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787. JKS-225 JKS-250 JKS-300 JKS-350 JKS-400 JKS-450 JKS-500 JKS-600 For superior electrical protection, Cooper Bussmann recommends upgrading JKS fuse applications to Low-Peak LPJ fuses See page 23. Recommended Fuse Holders & Blocks For Class J Fuses Data Sheet: 1026 (1-60) and 1027 (70-600) 24 10,000 1,000 100 40 AMP RATING 100,000 600 400 200 100 60 10,000 30 A 1,000 * See page 14 B 400,000 200,000 JKS-70 JKS-80 JKS-90 JKS-100 JKS-110 JKS-125 JKS-150 JKS-175 JKS-200 Current Limitation Curves 100,000 JKS-15 JKS-20 JKS-25 JKS-30 JKS-35 JKS-40 JKS-45 JKS-50 JKS-60 CURRENT IN AMPS 10,000 JKS-1 JKS-2 JKS-3 JKS-4 JKS-5 JKS-6 JKS-8 JKS-10 JKS-12 .01 1,000 Typical Applications * Power Panelboards * Machinery Disconnects Catalog Numbers (Amps) .1 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS Features and Benefits * Current limitation for non-inductive circuits provides Class J current-limiting response to maximum ground fault and short-circuit conditions. * 200kA interrupting rating provides high ratings at all circuit locations. * Economical solutions for high-fault circuits. 1 RMS SYMMETRICAL CURRENTS IN AMPS A-B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage, Branch Circuit Rated Fuses One-time General Purpose Fuses Low Voltage Branch Circuit Fuses NON (250Vac/125Vdc) Class K5 & H NOS (600Vac) Catalog Numbers (Amps) NOS (600Vac) Class K5 & H NOS-1 NOS-12 NOS-70 NOS-200 NOS-2 NOS-15 NOS-75 NOS-225 Specifications Description: General purpose, non-current-limiting fuses. Dimensions: See page 15 for dimensions. Ratings: Volts -- NON: -- 250Vac -- 125Vdc (0-100A) -- NOS: -- 600Vac Amps -- 18-600A IR -- 50kA RMS Sym. (NON & NOS Class K5 0-60A) -- 10kA RMS Sym. (NON & NOS Class H65-600A) -- 50kA @ 125Vdc (NON Class K5 0-60A) -- 10kA @ 125Vdc (NON Class H 65-100A) Agency Information: CE, UL Listed - 250V: Class K5 (0-60A), Std. 248-9, Class H (65-600A), Std. 248-6, (125Vdc: NON 0-100), 600V: Class K5 (0-60A), Std. 248-9, Class H (70-600A), Std. 248-6, Guide JDDZ, File E4273, CSA Certified - 250V: (0-12, 65-600), 600V: (0-600), Class 1421-01, File 53787. NOS-3 NOS-20 NOS-80 NOS-250 NOS-4 NOS-25 NOS-90 NOS-300 NOS-5 NOS-30 NOS-100 NOS-350 NOS-6 NOS-35 NOS-110 NOS-400 NOS-7 NOS-40 NOS-125 NOS-450 NOS-8 NOS-45 NOS-150 NOS-500 NOS-9 NOS-50 NOS-175 NOS-600 NOS-10 NOS-60 Recommended Fuse Reducers 250V Fuse Amp Size Clip Amp Size Catalog Number (Pair) 600V Fuse Amp Size Clip Amp Size Catalog Number (Pair) 30 60 NO.263 30 60 NO.663 30 100 NO.213 30 100 NO.216 60 100 NO.216 60 100 NO.616 60 200 NO.226 60 200 NO.626 100 200 NO.2621 100 200 NO.2621 100 400 NO.2641 100 400 NO.2641 200 400 NO.2642 200 400 NO.2642 100 600 NO.2661 100 600 NO.2661 200 600 NO.2662 200 600 NO.2662 400 600 NO.2664 400 600 NO.2664 For CSA Certified 15-60A Ratings, see PON Data Sheet 4126 Features and Benefits * Original fuse providing circuit protection. Typical Applications * Light Duty Circuit Locations NON (250Vac) Catalog Numbers (Amps) NON-18 NON-5 NON-40 NON-12 NON-6 NON-45 NON-200 NON-34 NON-6-14 NON-50 NON-225 NON-810 NON-7 NON-60 NON-250 NON-1 NON-8 NON-65 NON-300 NON-1-14 NON-9 NON-70 NON-350 NON-1-12 NON-10 NON-75 NON-400 NON-1-610 NON-12 NON-80 NON-450 NON-2 NON-15 NON-90 NON-500 NON-2-12 NON-20 NON-100 NON-600 NON-3 NON-25 NON-110 NON-3-210 NON-30 NON-125 NON-4 NON-35 NON-150 NON-175 For superior electrical protection, Cooper Bussmann recommends upgrading NON (250Vac) and NOS (600Vac) fuse applications to Low-Peak LPN-RK (250Vac) and LPSRK (600Vac) fuses See page 29. Recommended Fuse Holders & Blocks For Class K5 & H 250V & 600V Fuses * See page 12 Data Sheet: 1030 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 25 Low Voltage, Branch Circuit Rated Fuses Low-Peak(R) Time-delay Fuses KRP-C_SP Class L Specifications Description: Time-delay fuse - 4 seconds (minimum) at 500% rated amps. Dimensions: See page 16 for Class L dimensions. Ratings: Volts -- 600Vac (or less) -- 300Vdc (601-2000A) Amps -- 601-6000A (use KRP-CL for current ratings under 601A) IR -- 300kA RMS Sym. -- 100kA DC Agency Information: CE, UL ListedSpecial Purpose (meets all performance requirements of UL Standard 248-10 for Class L fuses),Guide JFHR, File E56412, CSA Certified (200k AIR), Class 1422-02, File 53787, Class L per CSA C22.2, No. 248.10. Catalog Numbers (Amps) KRP-C-601SP KRP-C-1000SP KRP-C-1800SP KRP-C-3500SP KRP-C-650SP KRP-C-1100SP KRP-C-1900SP KRP-C-3800SP KRP-C-700SP KRP-C-1200SP KRP-C-2000SP KRP-C-4000SP KRP-C-750SP KRP-C-1350SP KRP-C-2001SP KRP-C-4500SP KRP-C-800SP KRP-C-1400SP KRP-C-2400SP KRP-C-5000SP KRP-C-801SP KRP-C-1500SP KRP-C-2500SP KRP-C-6000SP KRP-C-900SP KRP-C-1600SP KRP-C-3000SP Features and Benefits * Time delay of four seconds at five times rating allows closer sizing on large motor loads combined with Class L current limitation. * Selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit. * Interrupting rating of 300kA RMS symmetrical provides adequate ratings without obsolescence for all electrical systems, big or small. * Quality construction, using high-grade materials, provides lower watts loss and operating temperatures with superior arc quenching during current-limiting action. Typical Applications * Large Distribution Switchboards * Power Panelboards * Large Machinery Disconnects Recommended Fuse Holders & Blocks For Class L Fuses * See page 13 Data Sheets: 1008 and 1009 26 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage, Branch Circuit Rated Fuses Low-Peak(R) Time-delay Fuses 4000A 5000A 6000A 1600A 2000A 2500A 3000A 1200A 800A Current Limitation Curves 1000,000 B AMP RATING AMP RATING A 1,000 300,000 1 10,000 100,000 10 100,000 10,000 100 6,000A 5,000A 4,000A 3,000A 2,500A 2,000A 1,600A 1,200A 800A 601A 1,000 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS 300 TIME IN SECONDS Branch Circuit Fuses Time-Current Characteristic Curves--Average Melt PROSPECITVE SHORT-CIRCUIT CURRENT SYMMETRICAL RMS AMPS 200,000 100,000 1,000 .01 10,000 .1 CURRENT IN AMPS KRP-CL Current-limiting, time-delay fuses Specifications Description: Current-limiting, time-delay fuse. Dimensions: See page 16 for Class L dimensions. Ratings: Volts -- 600Vac (or less) Amps -- 150-600A IR -- 200kA RMS Sym. Features and Benefits * Time-delay of four seconds at five times rating allows closer sizing inductive loads coupled with an equivalent Class L current limitation. Data Sheets: 1008 and 1009 * Class L case size for amp ratings from 150A to 600A allows downsize fusing of large Class L fused switches for improved circuit protection. Typical Applications * Large Distribution Switchboards * Power Panelboards * Machinery Disconnects Catalog Numbers (Amps) KRP-CL-150 KRP-CL-300 KRP-CL-500 KRP-CL-200 KRP-CL-350 KRP-CL-600 KRP-CL-225 KRP-CL-400 KRP-CL-250 KRP-CL-450 Recommended Fuse Holders & Blocks For Class L Fuses * See page 13 Data Sheet: 1016 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 27 Low Voltage, Branch Circuit Rated Fuses Limitron(R) Fuses KTU Class L KLU Class L Specifications Description: Fast-acting, bolt-mount fuse. Dimensions: See page 16 for Class L dimensions. Ratings: Volts -- 600Vac (or less) Amps -- 601-6000A IR -- 200kA RMS Sym. Agency Information: CE, Std. 248-10, Class L, UL Listed, Guide JDDZ, File E4273 CSA Certified, Class 1422-02, File 53787. Specifications Description: Time-delay, bolt-mount fuse - 5 seconds (minimum) at 500% rated amps. See KRP-CL for amp ratings below 601A. Dimensions: See page 16 for Class L dimensions. Ratings: Volts -- 600Vac (or less) Amps -- 601-4000A IR -- 200kA RMS Sym. Agency Information: CE, Std. 248-10, Class L, UL Listed, Guide JDDZ, File E4273, CSA Certified, CSA Class 142202, File 53787. Features and Benefits * 200kA interrupting rating provides high ratings at all circuit locations. * Economical solutions for high-fault circuits. * Quality construction using high-grade materials provides lower watts loss and operating temperatures with superior arc quenching during current-limiting action. Features and Benefits * 200kA interrupting rating provides high ratings at all circuit locations. * Economical solutions for high fault circuits. Typical Applications * Large Distribution Switchboards * Power Panelboards * Large Machinery Disconnects Typical Applications * Large Distribution Switchboards * Power Panelboards Catalog Number (Amps) Catalog Numbers (Amps) KTU-601 KTU-1100 KTU-2400 KLU-601 KLU-1200 KLU-2500 KTU-650 KTU-1200 KTU-2500 KLU-650 KLU-1500 KLU-3000 KTU-700 KTU-1350 KTU-3000 KLU-700 KLU-1600 KLU-4000 KTU-750 KTU-1400 KTU-3001 KLU-800 KLU-1800 KTU-800 KTU-1500 KTU-4000 KLU-1000 KLU-2000 KTU-801 KTU-1600 KTU-4500 KTU-900 KTU-1800 KTU-5000 KTU-1000 KTU-2000 KTU-6000 For superior electrical protection, Cooper Bussmann recommends upgrading KTU fuse applications to Low-Peak KRP-C fuses See page 26. For superior electrical protection, Cooper Bussmann recommends upgrading KLU fuse applications to Low-Peak KRP-C fuses See page 26. Recommended Fuse Holders & Blocks For Class L Fuses Recommended Fuse Holders & Blocks For Class L Fuses * See page 13 * See page 13 Data Sheet: 1010 Data Sheet: 1013 28 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage, Branch Circuit Rated Fuses Low-Peak(R) Dual-element, Time-delay Fuses LPS-RK_SP (600V) Class RK1 Available With * * * * Low Voltage Branch Circuit Fuses LPN-RK_SP (250V) Class RK1 Typical Applications Large Distribution Switchboards Power Panelboards Motor Control Centers Machinery Disconnect Switches Indication Specifications Description: Current-limiting, dual-element, time-delay fuse; 10 seconds (minimum) at 500% rated amps (8 seconds for 0-30A sizes). Now available with optional indication on select ratings (see Catalog Numbers table). Dimensions: See page 15 for Class RK1 dimensions. Ratings: Volts LPN-RK: -- 250Vac (or less) -- 125Vdc (0-60A) -- 250Vdc (70-600A) LPS-RK: -- 600Vac (or less) -- 300Vdc Amps -- 110-600A IR -- 300kA RMS Sym. -- 100kA DC Agency Information: CE, UL Listed - Special Purpose*, Guide JFHR, File E56412, CSA Certified (200k AIR), Class RK1 per CSA C22.2, No. 248.12, Class 1422-02, File 53787. Features and Benefits * Separate overload and short-circuit elements provide time delay for close sizing of high inrush loads linked with RK1 current-limitation and selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents widespread blackouts. * Inventory consolidation of Class RK1, RK5 and H fuses for reduced SKU investment and minimizing potential for misapplying fuse. * 300kA RMS symmetrical interrupting rating provides adequate ratings without obsolescence for all electrical systems, big or small. * Insulated end caps reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing. Data Sheets: LPN-RK -- 1003 (0-60) and 1004 (70-600) LPN-RK with indication -- 1066 (70-600) LPS-RK -- 1001 (0-60) and 1002 (70-600) LPS-RK with indication -- 1061 (0-60) and 1064 (70-600) LPN Catalog Numbers (Amps) LPN-RK-110SP LPN-RK-3-12SP LPN-RK-15100SP LPN-RK-4SP LPN-RK-70SP** LPN-RK-210SP LPN-RK-4-12SP LPN-RK-80SP** LPN-RK-310SP LPN-RK-5SP LPN-RK-90SP** LPN-RK-410SP LPN-RK-5-610SP LPN-RK-100SP** LPN-RK-12SP LPN-RK-6SP LPN-RK-110SP** LPN-RK-610SP LPN-RK-6-14SP LPN-RK-125SP** LPN-RK-810SP LPN-RK-8SP LPN-RK-150SP** LPN-RK-1SP LPN-RK-9SP LPN-RK-175SP** LPN-RK-1-18SP LPN-RK-10SP LPN-RK-200SP** LPN-RK-1-14SP LPN-RK-12SP LPN-RK-225SP** LPN-RK-1-410SP LPN-RK-15SP LPN-RK-250SP** LPN-RK-1-610SP LPN-RK-17-12SP LPN-RK-300SP** LPN-RK-1-81 SP 0 LPN-RK-20SP LPN-RK-350SP** LPN-RK-2SP LPN-RK-25SP LPN-RK-400SP** LPN-RK-2-14SP LPN-RK-30SP LPN-RK-450SP** LPN-RK-2-12SP LPN-RK-35SP** LPN-RK-500SP** LPN-RK-2-810SP LPN-RK-40SP** LPN-RK-600SP** LPN-RK-3SP LPN-RK-45SP** LPN-RK-60SP** LPN-RK-3-210SP LPN-RK-50SP** *Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses. **Available with optional indication. To order, place "I" at end of Catalog Number. Example: LPN-RK-35SPI. 0-60A fuses available with Nickel plate option. (Ex: LPS-RK30SPNP) 70-600A fuses available with Tin plate option. Example: LPS-RK-100SP-TP. LPS Catalog Numbers - (Amps) LPS-RK-110SP LPS-RK-2-12SP LPS-RK-12SP** LPS-RK-110SP** LPS-RK-210SP LPS-RK-2-810SP LPS-RK-15SP** LPS-RK-125SP** LPS-RK-310SP LPS-RK-3SP LPS-RK-17-12SP** LPS-RK-150SP** LPS-RK-410SP LPS-RK-3-210SP LPS-RK-20SP** LPS-RK-175SP** LPS-RK-12SP LPS-RK-3-12SP LPS-RK-25SP** LPS-RK-200SP** LPS-RK-610SP LPS-RK-4SP LPS-RK-30SP** LPS-RK-225SP** LPS-RK-810SP LPS-RK-4-12SP LPS-RK-35SP** LPS-RK-250SP** LPS-RK-1SP LPS-RK-5SP LPS-RK-40SP** LPS-RK-300SP** LPS-RK-1-18SP LPS-RK-5-610SP LPS-RK-45SP** LPS-RK-350SP** LPS-RK-1-14SP LPS-RK-6SP** LPS-RK-50SP** LPS-RK-400SP** LPS-RK-1-410SP LPS-RK-6-14SP** LPS-RK-60SP** LPS-RK-450SP** LPS-RK-1-12SP LPS-RK-7SP** LPS-RK-70SP** LPS-RK-500SP** LPS-RK-1-610SP LPS-RK-8SP** LPS-RK-80SP** LPS-RK-600SP** LPS-RK-1-810SP LPS-RK-9SP** LPS-RK-90SP** LPS-RK-2-14SP LPS-RK-10SP** LPS-RK-100SP** *Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses. **Available with optional replace fuse indication. To order, place "I" at end of Catalog Number. Example: LPS-RK-15SPI. Recommended Fuse Holders & Blocks For Class RK1 Fuses * See page 13 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 29 Low Voltage, Branch Circuit Rated Fuses Low-Peak(R) Dual-element, Time-delay Fuses 61/4 21/2 4 5 8 10 12 2 LPN-RK AMP RATING 32/10 11/4 1 300 16/10 400 600 1/2 200 8/10 100 6/10 60 3/10 4/10 AMP RATING 15 20 30 1/10 300 2/10 LPN-RK 15/100 Time-Current Characteristic Curves--Average Melt 100 100 10 TIME IN SECONDS 1 1 CURRENT IN AMPS LPS-RK 1,000 10 1 10,000 20 100 1,000 .1 .01 RMS SYMMETRICAL CURRENT IN AMPS 15/100 1/10 10 61/4 2 32/10 400 600 11/4 200 8/10 1 16/10 21/2 4 5 8 12 100 1/2 60 4/10 30 300 6/10 AMP RATING 20 2/10 .01 100 .1 .1 3/10 TIME IN SECONDS 10 LPS-RK AMP RATING 100 TIME IN SECONDS TIME IN SECONDS 10 1 .1 CURRENT IN AMPS CURRENT IN AMPS 10,000 1,000 100 20 .01 Recommended Fuse Holders & Blocks For Class RK1 Fuses Data Sheets: LPN-RK -- 1003 (0-60) and 1004 (70-600) Data Sheets: LPS-RK -- 1001 (0-60) and 1002 (70-600) 30 * See page 13 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage, Branch Circuit Rated Fuses Low-Peak(R) Dual-element, Time-delay Fuses Low Voltage Branch Circuit Fuses B AMP RATING 400,000 100,000 600 400 200 100 60 10,000 30 200,000 100,000 1,000 10,000 A 1,000 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS Current Limitation Curves--LPN-RK RMS SYMMETRICAL CURRENTS IN AMPS A-B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) Current Limitation Curves--LPS-RK INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS B Data Sheets: LPN-RK -- 1003 (0-60) and 1004 (70-600) Data Sheets: LPS-RK -- 1001 (0-60) and 1002 (70-600) Recommended Fuse Holders & Blocks For Class RK1 Fuses * See page 13 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 31 Low Voltage, Branch Circuit Rated Fuses Limitron(R) Fast-acting Fuses Time-Current Characteristic Curves--Average Melt KTN-R (250V) Class RK1 Specifications Description: Fast-acting, current-limiting fuse. Dimensions: See page 15 for Class RK1 dimensions. Ratings: Volts -- 250Vac (or less) Amps -- 1-600A IR -- 200kA RMS Sym. Agency Information: CE, Std. 248-12, Class RK1, UL Listed, Guide JDDZ, File E54273, CSA Certified, Class 1422-02, File 53787. Features and Benefits * Current limitation for non-inductive circuits provides Class RK1 current-limiting response to maximum ground fault and short-circuit conditions. * 200kA interrupting rating provides high ratings at all circuit locations. * Economical solutions for high-fault circuits. Typical Applications * Panelboards Catalog Numbers (Amps) KTN-R-1 KTN-R-2 KTN-R-3 KTN-R-4 KTN-R-5 KTN-R-6 KTN-R-8 KTN-R-10 KTN-R-12 KTN-R-15 KTN-R-20 KTN-R-25 KTN-R-30 KTN-R-35 KTN-R-40 KTN-R-45 KTN-R-50 KTN-R-60 KTN-R-70 KTN-R-75 KTN-R-80 KTN-R-90 KTN-R-100 KTN-R-110 KTN-R-125 KTN-R-150 KTN-R-175 KTN-R-200 KTN-R-225 KTN-R-250 KTN-R-300 KTN-R-350 KTN-R-400 KTN-R-450 KTN-R-500 KTN-R-600 Current Limitation Curves For superior electrical protection, Cooper Bussmann recommends upgrading KTN-R fuse applications to Low-Peak LPN-RK fuses See page 29. Recommended Fuse Holders & Blocks For Class RK1 Fuses * See page 13 Data Sheet: 1043 32 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage, Branch Circuit Rated Fuses Limitron(R) Fast-acting Fuses Low Voltage Branch Circuit Fuses Features and Benefits * Current limitation for non-inductive circuits provides Class RK1 current-limiting response to maximum ground fault an short-circuit conditions. * 200kA interrupting rating provides high ratings at all circuit locations. * Economical solutions for applications with high available short-circuit current. CURRENT IN AMPS 25 30 15 6 8 10 1 300 200 100 10 TIME IN SECONDS Specifications Description: Fast-acting, current-limiting fuse. Dimensions: See page 15 for Class RK1 dimensions. Ratings: Volts -- 600Vac (or less); 600Vdc (20-600A) Amps -- 1-600A IR -- 200kA RMS Sym. AC IR -- 100kA DC Agency Information: CE, Std. 248-12, Class RK1, UL Listed, Guide JDDZ, File E54273. 3 Time-Current Characteristic Curves--Average Melt KWS-R (600Vac/dc) Class RK1 1 .1 200 100 1 KWS-R-125 KWS-R-150 KWS-R-175 KWS-R-200 KWS-R-225 KWS-R-250 KWS-R-300 KWS-R-350 KWS-R-400 KWS-R-500 KWS-R-600 20 KWS-R-25 KWS-R-30 KWS-R-35 KWS-R-40 KWS-R-45 KWS-R-50 KWS-R-60 KWS-R-70 KWS-R-80 KWS-R-90 KWS-R-100 10 KWS-R-1 KWS-R-2 KWS-R-3 KWS-R-4 KWS-R-5 KWS-R-6 KWS-R-8 KWS-R-10 KWS-R-12 KWS-R-15 KWS-R-20 2 .01 Catalog Numbers (Amps) 300 400 500 600 700 Typical Applications * Photovoltaic systems * Inverters * Panelboards CURRENT IN AMPS Current Limitation Curves Recommended Fuse Holders & Blocks For Class RK1 Fuses * See page 13 Data Sheet: 4204 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 33 Low Voltage, Branch Circuit Rated Fuses Dura-LagTM Dual-element, Time-delay Fuses DLN-R (250V) Class RK5 DLS-R (600V) Class RK5 Specifications Description: Dual-element, time-delay fuse - 10 seconds (minimum) at 500% rated amps (8 seconds for 0-30A sizes). Dimensions: See page 15 for Class RK5 dimensions. Ratings: Volts -- 250Vac (or less) Amps -- 1-600A IR -- 200kA RMS Sym. -- 20kA DC Agency Information: CE, Std. 248-12, Class RK5, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02 File 53787. Features and Benefits * Separate overload and short-circuit elements provide time delay for close inductive load sizing, linked with RK5 current limitation. * 200kA interrupting rating provides high ratings at all circuit locations. Typical Applications * Power Panelboards * Machinery Disconnects Specifications Description: Dual-element, time-delay fuse - 10 seconds (minimum) at 500% rated amps. Dimensions: See page 15 for Class RK5 dimensions. Ratings: Volts -- 600Vac (or less) Amps -- 1-600A IR -- 200kA RMS Sym. Agency Information: CE, Std. 248-12, Class RK5, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02 File 53787. Features and Benefits * Separate overload and short-circuit elements provide time delay for close inductive load sizing, linked with RK5 current limitation. * 200kA interrupting rating provides high ratings at all circuit locations. Typical Applications * Power Panelboards * Machinery Disconnects Catalog Numbers (Amps) Catalog Numbers (Amps) DLN-R-1 DLN-R-15 DLN-R-100 DLN-R-2 DLN-R-20 DLN-R-125 DLN-R-2-12 DLN-R-25 DLN-R-150 DLN-R-3 DLN-R-30 DLN-R-175 DLN-R-3-210 DLN-R-35 DLN-R-200 DLN-R-4 DLN-R-40 DLN-R-225 DLN-R-5 DLN-R-45 DLN-R-250 DLN-R-6 DLN-R-50 DLN-R-300 DLN-R-6-14 DLN-R-60 DLN-R-400 DLN-R-8 DLN-R-70 DLN-R-600 DLN-R-10 DLN-R-80 DLN-R-12 DLN-R-90 For superior electrical protection, Cooper Bussmann recommends upgrading DLN-R fuse applications to Low-Peak LPN-RK fuses See page 29. DLS-R-1 DLS-R-12 DLS-R-100 DLS-R-1-610 DLS-R-15 DLS-R-110 DLS-R-2 DLS-R-17-12 DLS-R-125 DLS-R-2-12 DLS-R-20 DLS-R-150 DLS-R-3 DLS-R-25 DLS-R-175 DLS-R-3-12 DLS-R-30 DLS-R-200 DLS-R-4 DLS-R-35 DLS-R-225 DLS-R-5 DLS-R-40 DLS-R-250 DLS-R-6 DLS-R-45 DLS-R-300 DLS-R-6-14 DLS-R-50 DLS-R-350 DLS-R-7 DLS-R-60 DLS-R-400 DLS-R-8 DLS-R-70 DLS-R-500 DLS-R-9 DLS-R-80 DLS-R-600 DLS-R-10 DLS-R-90 For superior electrical protection, Cooper Bussmann recommends upgrading DLS-R fuse applications to Low-Peak LPS-RK fuses See page 29. Recommended Fuse Holders & Blocks For Class RK5 Fuses Recommended Fuse Holders & Blocks For Class RK5 Fuses * See page 13 * See page 13 Data Sheet: 1021 Data Sheet: 1022 34 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage, Branch Circuit Rated Fuses Fusetron(R) Dual-element, Time-delay Fuses FRN-R-2 FRN-R-10* FRN-R-100 FRN-R-18 FRN-R-2-14 FRN-R-12* FRN-R-110 FRN-R-15100 FRN-R-2-12 FRN-R-15* FRN-R-125 FRN-R- 10 FRN-R-2-810 FRN-R-17-12* FRN-R-150 FRN-R-14 FRN-R-3 FRN-R-20* FRN-R-175 FRN-R- 10 FRN-R-3- 10 FRN-R-25* FRN-R-200 FRN-R-410 FRN-R-3-12 FRN-R-30* FRN-R-225 FRN-R-12 FRN-R-4 FRN-R-35* FRN-R-250 FRN-R-610 FRN-R-4-12 FRN-R-40* FRN-R-300 FRN-R-810 FRN-R-5 FRN-R-45* FRN-R-350 FRN-R-5-610 FRN-R-50* FRN-R-400 FRN-R-1- 8 FRN-R-6 FRN-R-60* FRN-R-450 FRN-R-1-14 FRN-R-6-14 FRN-R-70 FRN-R-500 FRN-R-1-410 FRN-R-7 FRN-R-75 FRN-R-600 FRN-R-1-12 FRN-R-7-12 FRN-R-80 FRN-R-1-610 FRN-R-8* FRN-R-85 FRN-R-1-810 FRN-R-9* FRN-R-90 2 3 2 FRN-R-1 1 *Available with indication. To order, place "ID" at the end of the catalog number. 400 600 200 60 100 30 Amp Rating 600 400 200 100 60 10,000 30 A 1,000 200,000 FRN-R-110 100,000 100,000 Catalog Numbers (Amps) FRN-R 10,000 * Combination Starters * Machinery Disconnects B 400,000 1,000 Typical Applications * Power Panelboards * Motor Control Centers Current Limitation Curves Instantaneous Peak Let-Through Current Amps Features and Benefits * Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA. * 2:1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses. * Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing. 8 10 15 Specifications Description: Dual-element, time-delay fuse - 10 seconds (minimum) at 500% rated amps (8 seconds for 0-30A sizes). Available with indication on select ratings (see Catalog Numbers table). Dimensions: See page 15 for Class RK5 dimensions. Ratings: Volts -- 250Vac (or less) -- 125Vdc (110-60A, 110-200A) -- 250Vdc (225-600A) Available With Amps -- 110-600A Indication IR -- 200kA RMS Sym. -- 20kA DC Agency Information: CE, Std. 248-12, Class RK5, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-01, File 53787. Branch Circuit Fuses Time-Current Characteristic Curves--Average Melt FRN-R (250V) Class RK5 RMS Symmetrical Currents In Amps A-B = Asymmetrical Available Peak (2.3 x Sym RMS Amps) For superior electrical protection, Cooper Bussmann recommends upgrading FRN-R fuse applications to Low-Peak(R) LPN-RK fuses. See page 29. Recommended Fuse Holders & Blocks For Class RK5 Fuses * See page 13 Recommended Fuse Reducers For Class R Fuses * See page 14 Data Sheets: 1019 (0-60) and 1020 (70-600) Data Sheet: 1169 (8-60) FRN-R with indication For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 35 Low Voltage, Branch Circuit Rated Fuses Fusetron(R) Dual-element, Time-delay Fuses Time-Current Characteristic Curves--Average Melt FRS-R (600V) Class RK5 Specifications Description: Dual-element, time-delay fuse - 10 seconds (minimum) at 500% rated amps. Now available with optional indication on select ratings (see Catalog Numbers table). Dimensions: See page 15 for Class RK5 dimensions. Ratings: Volts -- 600Vac (or less) -- 300Vdc Amps -- 110-600A Available With IR -- 200kA RMS Sym. Indication -- 20kA @ 300Vdc Agency Information: CE, Std. 248-12, Class RK5, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787. Time In Seconds Amp Rating Features and Benefits * 2:1 selective coordination ratio (within RK5 fuse family) prevents electrical shutdowns from extending beyond the failed circuit. * Insulated end caps for 70-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing. Current In Amps Current Limitation Curves FRS-R-110 FRS-R-15100 FRS-R-2-12 FRS-R-15* FRS-R-125 FRS-R-210 FRS-R-2-810 FRS-R-17-12* FRS-R-150 FRS-R-14 FRS-R-3 FRS-R-20* FRS-R-175 FRS-R- 10 FRS-R-3- 10 FRS-R-25* FRS-R-200 FRS-R-410 FRS-R-3-12 FRS-R-30* FRS-R-225 FRS-R-12 FRS-R-4 FRS-R-35* FRS-R-250 FRS-R-610 FRS-R-4-12 FRS-R-40* FRS-R-300 FRS-R- 10 FRS-R-5 FRS-R-45* FRS-R-350 FRS-R-1 FRS-R-5-610 FRS-R-50* FRS-R-400 FRS-R-1-18 FRS-R-6* FRS-R-60* FRS-R-450 FRS-R-1-14 FRS-R-6-14* FRS-R-65 FRS-R-500 FRS-R-1-410 FRS-R-7* FRS-R-70 FRS-R-600 FRS-R-1-12 FRS-R-7-12* FRS-R-75 FRS-R-1-610 FRS-R-8* FRS-R-80 FRS-R-1 810 FRS-R-9* FRS-R-90 3 8 2 *Available with indication. To order, place "ID" at the end of the catalog number. Example: FRS-R-7ID. FRS-R (600V) Amp Rating FRS-R-100 FRS-R-12* 100,000 600A 400A 200A 100A 60A 30A 10,000 15A A 1,000 100,000 FRS-R-10* FRS-R-2-14 10,000 FRS-R-2 FRS-R-18 Instantaneous Peak Let-Through Current Amps FRS-R- 10 1 B 400,000 Catalog Numbers (Amps) 200,000 * Combination Starters * Machinery Disconnects 1,000 Typical Applications * Power Panelboards * Motor Control Centers RMS Symmetrical Currents In Amps A-B = Asymmetrical Available Peak (2.3 x Sym RMS Amps) For superior electrical protection, Cooper Bussmann recommends upgrading FRS-R fuse applications to Low-Peak LPS-RK fuses. See page 29. Recommended Fuse Holders & Blocks For Class RK5 Fuses Data Sheet: 1017 (0-60), 1018 (70-600) Data Sheet: 1070 (6-60) FRS-R with Indication Recommended Fuse Reducers For Class R Fuses 36 * See page 13 * See page 14 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage, Branch Circuit Rated Fuses Limitron(R) Fast-acting Fuses Low Voltage Branch Circuit Fuses Time-Current Characteristic Curves--Average Melt PVS-R (600Vac/dc) Class RK5 Specifications Description: A range of UL 2579 fast-acting 600Vdc Class RK5 fuses specifically designed to protect solar power systems in extreme ambient temperature, high cycling and low level fault current conditions (reverse current, multi-array fault). Dimensions: See page 15 for Class RK5 dimensions. Ratings: Volts -- 600Vac to UL 248-12 ed Design new 600Vdc to UL 2579 t the e e m se to Amps -- 20-350A aic Fu otovolt h P L U rd IR -- 200kA RMS Sym. AC Standa 20kA DC (20-60A) 10kA DC (70-350A) Agency Information: UL Std. 248-12, Class RK5, UL Listed, Guide JFGA, File E335324. Photovoltaic to UL 2579, CSA Component Certified C22.2. Features and Benefits * Current limitation for non-inductive circuits provides Class RK5 current-limiting response to ground fault and short-circuit conditions. * Designed for the protection and isolation of photovoltaic systems. Typical Applications * Photovoltaic systems * Inverters Catalog Numbers (Amps) PVS-R-20 PVS-R-25 PVS-R-30 PVS-R-35 PVS-R-40 PVS-R-50 PVS-R-60 PVS-R-70 PVS-R-80 PVS-R-90 PVS-R-100 PVS-R-125 PVS-R-150 PVS-R-175 PVS-R-200 PVS-R-225 PVS-R-250 PVS-R-300 PVS-R-350 Recommended Fuse Holders & Blocks For Class RK5 Fuses * See page 13 Data Sheet: 4203 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 37 Low Voltage, Branch Circuit Rated Fuses T-Tron(R) Fast-acting Fuses Time-Current Characteristic Curves--Average Melt JJN Class T Specifications Description: Fast-acting, current-limiting fuse. Dimensions: See page 16 for Class T dimensions. Ratings: Volts -- 300Vac (or less) -- 160Vdc (15-600A) -- 170Vdc (601-1200A) Amps -- 1-1200A IR -- 200kA RMS Sym. -- 20kA DC @ 160Vdc -- 100kA DC @ 170Vdc Agency Information: CE, Std. 248-15, Class T, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787. Features and Benefits * Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer. * Current limitation for non-inductive circuits provides Class T current-limiting response to maximum ground fault and short-circuit conditions. * 200kA interrupting rating provides high ratings at all circuit locations. * Small footprint allows more efficient use of available space. Typical Applications * Large Apartment Complexes * Multi-Family Meter Stacks * VFD Line Protection Catalog Numbers (Amps) JJN-1 JJN-15 JJN-40 JJN-80 JJN-150 JJN-300 JJN-600 JJN-2 JJN-20 JJN-45 JJN-90 JJN-175 JJN-350 JJN-700 JJN-3 JJN-25 JJN-50 JJN-100 JJN-200 JJN-400 JJN-800 JJN-6 JJN-30 JJN-60 JJN-110 JJN-225 JJN-450 JJN-1000 JJN-10 JJN-35 JJN-70 JJN-125 JJN-250 JJN-500 JJN-1200 Current Limitation Curves JJN Recommended Fuse Holders & Blocks For Class T Fuses * See page 13 Data Sheet: 1025 38 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage, Branch Circuit Rated Fuses T-Tron(R) Fast-acting Fuses Specifications Description: Very fast-acting, current-limiting fuse. Dimensions: See page 16 for Class T dimensions. Ratings: Volts -- 600Vac (or less) Amps -- 1-800A IR -- 200kA RMS Sym. Agency Information: CE, Std. 248-15, Class T, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787. Low Voltage Branch Circuit Fuses Time-Current Characteristic Curves--Average Melt JJS Class T JJS Features and Benefits * Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer. * Current limitation for non-inductive circuits provides Class T current-limiting response to maximum ground fault and short-circuit conditions. * 200kA interrupting rating provides high ratings at all circuit locations. * Small footprint allows more efficient use of available space. Typical Applications * Large Apartment Complexes * Multi-Family Meter Stacks * VFD Line Protection Current Limitation Curves Catalog Numbers (Amps) JJS-1 JJS-15 JJS-40 JJS-80 JJS-150 JJS-300 JJS-600 JJS-2 JJS-20 JJS-45 JJS-90 JJS-3 JJS-25 JJS-50 JJS-100 JJS-175 JJS-350 JJS-800 JJS-200 JJS-400 JJS-6 JJS-30 JJS-60 JJS-110 JJS-225 JJS-450 JJS-10 JJS-35 JJS-70 JJS-125 JJS-250 JJS-500 JJS Recommended Fuse Holders & Blocks For Class T Fuses * See page 13 Data Sheet: 1029 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 39 Low Voltage, Branch Circuit Rated Fuses Plug Fuses W Series SL and TL Series Specifications Description: Fast-acting plug fuse. Dimensions: Edison base plug. Construction: Brass threads with plastic body. Ratings: Volts -- 125Vac Amps -- 12-12A IR -- 10kA RMS Sym. Agency Information: CE, Std. 248-11, UL Listed, Guide JEFV, File E12112. Specifications Description: Time-delay, loaded link plug fuse. Dimensions: SL -- Rejection base TL -- Edison base Construction: SL -- Plastic base with rejection threads TL -- Brass threads with plastic body Ratings: Volts -- 125Vac Amps -- 15-30A IR -- 10kA RMS Sym. Agency Information: CE, Std. 248-11, UL Listed, Guide JEFV, File E12112. Features and Benefits * Dependable, fast-acting circuit protection with 10kA interrupting rating for added safety when applied to existing plug fuse systems and 125-volt single-phase control circuits. Typical Applications * Replacement only in existing systems. * For general purpose circuit protection. * Use for lighting and other non-motor circuits. Catalog Numbers* (Amps) W-12 W-1 W-1 810 W-2 W-2 12 W-3 W-4 W-5 W-6 W-6 12 W-7 W-8 W-10 W-12 W-DUMMY** *W-15, W-20, W-25, and W-30 plug fuses obsoleted. Suggest replacing with either T-(Amp) or TL-(Amp) plug fuses. ** Non-conductive dummy base. Not a fuse. Features and Benefits * Time-delay loaded link TL Series Edison base plug fuses pass motor overload starting currents without opening and allow closer sizing to motor load for added protection. * Time-delay loaded link SL Series fuses provide a rejection feature (when used alone or with Fustat adapters to retrofit Edison base holders) to help prevent overfusing. Typical Applications * Small motor and inductive load circuits with high in-rush current levels. * Used with box cover units to provide equipment protection. * Applications benefiting from fuse rejection (SL Series only). SL Catalog Numbers (Amps) SL-15 SL-20 SL-25 SL-30 TL Catalog Numbers (Amps) TL-15 TL-20 TL-25 EDA*** EDN**** TL-30 *** Non-conductive Edison base dummy. Not a fuse. **** Conductive Edison base dummy. Not a fuse. Data Sheets: 1033 (SL) & 1035 (TL) Data Sheet: 1036 Recommended Fuse Holders For W Series Plug Fuses * See page 14 40 Recommended Fuse Holders For SL & TL Series Plug Fuses * See page 14 * See page 42 for Fustat adapters for use with SL Series For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage, Branch Circuit Rated Fuses Plug Fuses P & TC Series Specifications Description: Dual-element, time-delay plug fuse. Dimensions: S -- Rejection base T -- Edison base Construction: S -- Plastic base with rejection threads T -- Brass threads with plastic body Ratings: Volts -- 125Vac Amps -- S Series: 14-30A -- T Series: 310-30A IR -- 10kA RMS Sym. Agency Information: CE, Std. 248-11, Type S and T: UL Listed (0-614) Guide JFHR, File E56412 (7-30A) Guide JEFV, File E12112; CSA Certified, Class 1423-01, File 53787. Specifications Description: P Series - Type P Dual-element fuse TC Series - Type D Dual-element, Time-delay fuse Dimensions: Edison base Construction: Brass threads with plastic body Ratings: Volts -- 125Vac or less Amps -- 15-30A IR -- 10kA Agency Information: P Series - CSA Certified TC Series - CSA Certified (Class 1423-01, File # 53787) Features and Benefits * Time-delay, dual-element T Series Edison base plug fuses provide small motor overload protection when used with box cover units. * Time-delay, dual-element S Series plug fuses provide a rejection feature (when used alone or with Fustat adapters to retrofit Edison base holders) to prevent overfusing of branch circuits. Typical Applications * S Series -- Residential Load Centers * T Series -- Box Cover Units for small motor overload protection * Applications benefiting from fuse rejection (S Series only) S Series Catalog S-14 S-810 S-310 S-1 S-410 S-1-18 1 S- 2 S-1-14 6 S- 10 S-1-410 Numbers (Amps) S-1-610 S-2-12 S-1-810 S-2-810 S-2 S-3 S-2-14 S-3-210 6 S-5- 10 S-3-12 S-4 S-4-12 S-5 S-6 S-6-14 S-7 S-8 S-9 S-10 S-12 T Series Catalog T-310 T-1-18 T-410 T-1-14 T-12 T-1-410 6 T- 10 T-1-610 8 T- 10 T-1-810 T-1 T-2 Numbers (Amps) T-2-14 T-4 T-2-12 T-4-12 T-2-810 T-5 T-3 T-5-610 T-3-210 T-6 T-3-12 T-6-14 T-7 T-8 T-9 T-10 T-12 T-14 T-15 T-20 T-25 T-30 EDA* EDN** S-14 S-15 S-20 S-25 S-30 Low Voltage Branch Circuit Fuses S and T Series Features and Benefits P Series * "P" rating for Canadian applications. * Non-time delay for non-inductive loads TC Series * "D" rating for Canadian applications * Heavy duty TC fuses are industrial strength products, featuring dual-element construction. * This spring loaded design provides superior short-circuit and overload protection. * The TC fuses have more time-delay than the medium duty fuses in order to better protect industrial motors and residential circuits. Typical Applications * P Series -- Non-inductive loads, residential load centers * TC Series -- Box Cover Units for small motor overload protection P Series Catalog Numbers (Amps) P-15 P-20 P-25 P-30 TC Series Catalog Numbers (Amps) TC-15 TC-20 TC-25 TC-30 * Non-conductive Edison base dummy. Not a fuse. ** Conductive Edison base dummy. Not a fuse. Data Sheet: 1032 (S) & 1034 (T) Recommended Fuse Holders For S & T Series Plug Fuses * See page 14 * See page 42 for Fustat adapters for use with S Series Data Sheet: 1039 (TC Series only) Recommended Fuse Holders For P & TC Series Plug Fuses * See page 14 * See page 42 for Fustat adapters for use with S Series For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 41 Low Voltage, Branch Circuit Rated Fuses Plug Fuses MB Edison Base Circuit Breakers Fustat Fuse Adapters Specifications Description: Adapters for using Type S and SL rejection fuses in Edison base fuse sockets. Specifications Description: Edison base manual reset circuit breakers. Dimensions: Edison base Construction: Brass threads with plastic body Ratings: Volts -- 125Vac only Amps -- 15-20A IR -- 10kA RMS Sym. Agency Information: UL Listed, File E14942 Features and Benefits * Fit standard Edison base fuse receptacles. * Resettable upon overload event. Typical Applications* * Replacing Edison base plug fuses in residential fuse panels. Catalog Numbers* (Amps) MB-15 MB-20 * Not for use in box cover units or for inductive loads. Features and Benefits * Fustat adapters screw into the "Edison" thread fuse sockets of standard fuse boxes making it easy to retrofit existing fuse installations * Available in various amp ratings to cover a wide range of rating requirements Typical Applications * Plug fuse installations where it is desirable to restrict fuse amp ratings Catalog Numbers (Amps) SA-1* SA-1-14* SA-1-610* SA-2* SA-2-12* SA-3-210* SA-4* SA-5* SA-6-14* SA-8* SA-10* SA-15** SA-20** SA-30** * Single motor circuits. ** Branch circuits. Fustat(R) Adapters for Small Motor Protection* Adapter Accepts Fuses SA-1 S-1 or smaller SA-1-14 S-1-14 or smaller SA-1-610 S-1-610 or smaller SA-2 S-2 or S-1-810 SA-2-12 S-2-12 to S-1-810 SA-3-210 S-3-210 to S-1-810 SA-4 S-4 to S-3-12 SA-5 S-5 to S-3-12 SA-6-14 S-6-14 to S-3-12 SA-8 S-8 to S-7 SA-10 S-10 to S-7 SA-15 S-15 to S-7 SA-20 S-20 SA-30 S-30 to S-20 * Both motor running and short-circuit protection. Fustat(R) Adapters for Branch Circuit Protection Adapter 42 Accepts Fuses SA-15 S-15 to S-7 SA-20 S-20 SA-30 S-25 SA 30 S-30 to S-20 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa RED indicates NEW information Low Voltage Supplementary Fuses Section Contents Page Fuse Holder & Block Selection Guide . . . . . 44-45 32" x 1 12" Fast-acting supplementary fuses BAF . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . 47 KTK . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 47 KLM . . . . . . . . . . . . . . . . . . . . . . 500V . . . . . . . . . . 47 DCM . . . . . . . . . . . . . . . . . . 600Vac/dc . . . . . . . . . . 47 Solar PV . . . . . . . . . . . . . . . . . . . .250V . . . . . . . . . . 48 13 32" x 1 12" Time-delay supplementary fuses FNM . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . 49 FNQ . . . . . . . . . . . . . . . . . . . . . . 500V . . . . . . . . . . 49 13 32" x 1 38" Fast-acting supplementary fuses BBS . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 50 KTQ . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 50 13 Pin indication fuses and actuator GBA . . . . . . . . . . . . . . . . . . . . . . 125V . . . . . . . . . . GLD . . . . . . . . . . . . . . . . . . . . . . 125V . . . . . . . . . . MIC . . . . . . . . . . . . . . 250V fast-acting . . . . . . . . . . . MIN . . . . . . . . . . . . . . 250V fast-acting . . . . . . . . . . . FNA . . . . . . . . . . . . . . 250V time-delay . . . . . . . . . . MIS . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . KAZ . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 51 51 51 51 51 52 52 Limiters ANN . . . . . . . . . . . . . . 125V fast-acting . . . . . . . . . 52 ANL . . . . . . . . . . . . . . 80Vdc time-delay . . . . . . . . . 52 4164 & 4164-FR . . . . . . . . . .fuse blocks . . . . . . . . . 52 In-line size rejecting fuses and fuse holders GLQ . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 53 GMQ . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 53 In-line non-rejecting fuses and fuse holders GLR . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 54 GMF . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 54 GRF . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 54 Automotive blade-type fuses ATC . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . ATC-_ID . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . ATM . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . ATM-_ID . . . . . . . . . . . . . . . . . . . .32Vdc . . . . . . . . . MAX . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . MAX-_ID . . . . . . . . . . . . . . . . . . . .32Vdc . . . . . . . . . 55 55 55 55 55 55 Automotive blade-type fuse holders HHC, HHD, HHF, HHG, ATC-FHID for ATC fuses . . . . 56 HHL, HHM, ATC-FHID for ATM fuses . . . . . . . . . . . . . 56 HHX for MAX fuses . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Low Voltage Supplementary Fuses Cable limiters & welder limiters K Series cable limiters . . . . . . . . . 600V . . . . . . . . . . 46 64000 & 68000 welder limiters . . . 600V . . . . . . . . . . 46 Low Voltage Supplementary Fuses Holders & Blocks for Low Voltage Supplementary Fuses Limiters Catalog Number Volts Page K Series . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . 68000 Series . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . 64000 Series . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . ANN Fast acting limiter . . . . . . . . . 125Vac/80Vdc . . . . . . . . . . . . ANL Time-delay limiter . . . . . . . . . 80Vdc . . . . . . . . . . . . . . . . . . 46 46 46 52 52 CH Series Holders Safety JTM Series Modular Type * CH Series Class J modular 1 to 3-pole, panel/DIN rail mount . .254 * Safety JTM Series modular holders, panel/DIN rail mount . . . . . 255 Blocks * Modular Type Fuse Blocks 250/600V, panel mount . . . . . . . . . 275 * H250 Series 1- to 3-pole 250V, panel mount . . . . . . . . . . . . . .260 * H600 Series 1- to 3-pole 600V, panel mount . . . . . . . . . . . . . .263 Blocks * Modular Type Fuse Blocks 600V, panel mount . . . . . . . . . . . . * J600 Series, panel mount . . . . . . . . . . . . . . . . . . . . . . . . . . . * JP Series pyramid blocks, panel mount . . . . . . . . . . . . . . . . . * BH Series modular-style open blocks, panel mount . . . . . . . . 275 266 268 275 H250 Series H600 Series J600 Series Limiter Blocks - ANN & ANL * Blocks for 4164 & 4164-FR . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 JP Series BH Series 4164 & 4164-FR 32" X 1 12" Fuses 13 Catalog Number Volts Page BAF . . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . KTK . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . KLM . . . . . . . . . . . . . . . . . . . . . . . 600Vac/dc . . . . . . . . . . . . . . . DCM . . . . . . . . . . . . . . . . . . . . . . 600Vac/dc . . . . . . . . . . . . . . . Solar PV . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . FNM . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . FNQ . . . . . . . . . . . . . . . . . . . . . . . 500V . . . . . . . . . . . . . . . . . . . 47 47 47 47 48 49 49 OPM-NG-SC3 Holders * * * * * * * * * * * * OPM-NG-SC3 3-pole, panel/DIN rail mount . . . . . . . . . . . . . . .252 OPM-1038R 3-pole, panel/DIN rail mount . . . . . . . . . . . . . . . .251 OPM-1038RSW 3-pole w/ switch, panel/DIN rail mount . . . . . 250 CH Series Global 1- to 3-pole, DIN rail mount . . . . . . . . . . . . . .259 HPG Panel mount fuse holder . . . . . . . . . . . . . . . . . . . . . . . . .286 HPC-D Panel mount fuse holder . . . . . . . . . . . . . . . . . . . . . . . 287 HPM Panel mount fuse holder . . . . . . . . . . . . . . . . . . . . . . . . 287 HPS Series Panel mount fuse holder . . . . . . . . . . . . . . . . . . . 286 HPF Series Panel mount fuse holder . . . . . . . . . . . . . . . . . . . .286 HEB Series 1-Pole in-line fuse holder . . . . . . . . . . . . . . . . . . . 279 HEX & HEY Series 2-Pole in-line fuse holders . . . . . . . . . . . . .279 NDNF1-WH Fuse holding rail mount terminal block . . . . . . . . 291 OPM-1038R & OPM-1038RSW HPG HPS CH Series HPM HPC-D HPF HEB Series Blocks * BM Series, panel/DIN rail with adapters . . . . . . . . . . . . . . . . . 274 * 3723, 3742 and 3743 multi-pole add-on fuse blocks . . . . . . . 290 HEX & HEY Series 44 NDNF1-WH For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa BM Series Low Voltage Supplementary Fuses Holders & Blocks for Low Voltage Supplementary Fuses 32" X 1 38" Fuses 13 Catalog Numbers Volts Page Low Voltage Supplementary Fuses BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 50 KTQ . . . . . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 50 Holder * HPS-L Panel mount holder . . . . . . . . . . . . . . . . . . . . . . . . . . .286 BM Series HPS-L Blocks * BM Series, panel/DIN rail with adapters . . . . . . . . . . . . . . . . . .274 * 3723, 3742 and 3743 multi-pole add-on fuse blocks . . . . . . . .290 Pin Indicating Fuses 4" X 114" Fuse Catalog Numbers Volts 1 Page GBA 14" X 1 14" . . . . . . . . . . . . . . . . . . . . .125V . . . . . . . . . . . . . . . 51 GLD 14" X 1 14" . . . . . . . . . . . . . . . . . . . . .125V . . . . . . . . . . . . . . . 51 MIC 1332" X 1 12" . . . . . . . . . . . . . . . . . . . .250V . . . . . . . . . . . . . . . 51 MIN 1332" X 1 12" . . . . . . . . . . . . . . . . . . . .250V . . . . . . . . . . . . . . . 51 FNA 1332" X 1 12" . . . . . . . . . . . . . . . . . . . .250V . . . . . . . . . . . . . . . 51 MIS 1332" X 2" . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 52 KAZ 1332" X 2" . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 52 HLD HK Series Holders * * 4" X 1 14": HLD Panel mount visual indication . . . . . . . . . . . . .285 4" X 1 14": HK Series Panel mount lamp indicating . . . . . . . . . .285 1 1 Blocks * 14" X 1 14": Series 8000 for visual indication . . . . . . . . . . . . . . .288 * 1332" X 1 12": 1-Pole signal block cat. # 3839 (not shown in catalog)* * 1332" X 2": 1-Pole signal block cat. # 2778 (not shown in catalog)* * 1332" X 2": 2-Pole signal block cat. # 2837 (not shown in catalog)* * 1332" X 2": 3-Pole signal block cat. # 2838 (not shown in catalog)* *Call our customer satisfaction team at 636-527-3877 for more information. Series 8000 Automotive Blade-type Fuses Catalog Numbers Volts Page ATC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . . . . . . 55 ATM . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . . . . . . 55 MAX . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . . . . . . 55 Holders * ATC: HHC, HHD, HHF, HHG & ATC-FHID In-line holders . . . . . . 56 * ATM: HHL, HHM & ATC-FHID In-line holders . . . . . . . . . . . . . . 56 * MAX: HHX In-line holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 HHC, HHD, HHF & HHG HHL & HHM HHX In-Line Rejecting and Non-Rejecting Fuses Catalog Number Volts Page GLQ rejecting fuse . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 53 GMQ rejecting fuse . . . . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 53 GLR non-rejecting fuse . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 54 GMF non-rejecting fuse . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 54 GRF non-rejecting fuse . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 54 Holders * GLQ & GMQ: HLQ Rejection holder . . . . . . . . . . . . . . . . . . . . . 53 * GLR, GMF & GRF: HLR & HLR-2A non-rejection holders . . . . . .54 HLQ3 Fuse Holders For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa HLR Fuse Holder 45 Low Voltage Supplementary Fuses Cable Limiters & Welder Limiters K Series 64000 & 68000 Series Specifications Description: Cable limiters. Ratings: Volts -- 600Vac IR -- 200,000A RMS Sym. @ 600Vac Agency Information: UL Listing: KDM, KDR, KDP and KFM, KCM, KCM-B and KCR. Specifications Description: Welder limiters. Ratings: Volts -- 600Vac (or less) IR -- 200,000A RMS Sym. Features and Benefits * Sizes and ratings available to meet many applications. Typical Applications * Protecting low voltage distribution and service entrance cables against short-circuit currents. Catalog Numbers Copper Cable Limiter -- 600 Volts Catalog Number Cable Size Catalog Number Cable Size Tubular Terminals KCY #4 KCF KCZ #3 KCH 250 MCM 4/0 KCA #2 KCJ1, 2 350 MCM KCB #1 KCM1, 2, 3, KCM-B1 500 MCM KCC 1/0 KCV KCD1, 2 2/0 KCR1, KCE 3/0 KCS 2 Nominal Amp Rating 68150 Class H 150 68200 Class H 200 68300 Class H 300 68400 Class H 400 68600 Class H 600 64200 Class J 200 64300 Class J 300 64400 Class J 400 64600 Class J 600 1 KQV #12 KDD 2/0 KQT #10 KDE 3/0 KFZ #8 KDF KIG #6 KDH 250 MCM KDY #4 KDJ1, 2 350 MCM KDA #2 KDM1, 2, KDB #1 KDU 600 MCM KDR1,2 750 MCM 1/0 Catalog Numbers Catalog Fuse Holder Numbers Type 600 MCM Tubular Terminal and Offset Bolt-Type Terminal KDC Typical Applications * Welder circuits * Because welder limiters have special characteristics, they are not intended for application on general-use circuits 750 MCM 1000 MCM 4/0 3 Features and Benefits * Current-limiting devices designed specially for use on welder circuits only * Time-current characteristics are designed to hold on the intermittent overloading encountered in welder operation, while providing short-circuit protection to the circuit and equipment * Welder limiters have excess current capacity in the operating range as needed for this type of service 500 MCM Compression Connector Rod and Tubular Terminals KEX KFH-A 4/0 250 MCM KQO 350 MCM KDT2 500 MCM *Center Bolt-Type Terminal and Off-Set Bolt-Type Terminal KPF 4/0 KFT1 250 MCM KEW1 350 MCM KDP1 500 MCM KFM1 750 MCM *Copper or aluminum cable; sizes of all other limiters pertain to copper only. 1 UL Listed (File E90818). 2 Available with shrink tube "_V" suffix. 3 Available with molded rubber boots. Add "-B" to end of part number. Accessories Boots can be purchased separately. For KCM Boot-KCM For KDM Boot-KDM Installation tools can be purchased separately from Thomas and Betts * Crimp Tool: TBM-14M * Die: 15506 KDM/15515 KDR Recommended Fuse Blocks For 68000 & 64000 Series limiters * See page 44 Data Sheet: 1042 46 Data Sheet: 1045 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage Supplementary Fuses 13 32" x 1 12" Fast-acting Fuses BAF DCM & KLM Specifications Class: Supplemental Description: Fastacting supplementary fuse. Dimensions: 1332" x 1 12 " (10.3 x 38.1mm). Ratings: Volts -- 600Vac (or less) Amps -- 110-30A IR -- 100kA RMS Sym. (UL) Agency Information: CE, Std. 248-14, UL Listed, Guide JDYX, File E19180. Specifications Class: Supplemental Description: Full range, fast-acting, DC midget fuse. Dimensions: 13 32" x 1 12" (10.3 X 38.1mm). Ratings: Volts -- 600Vac/dc Amps -- 110-30A IR -- 100kA AC -- 50kA DC Agency Information: CE, UL Listed: STD. 248-14, (FILE #E19180, GUIDE #JDYX), CSA Certified, C22.2 NO. 248. 14 (CLASS #1422-01, FILE #53787). Specifications Class: Supplemental Description: Fast-acting supplementary fuse. Dimensions: 1332" x 1 12 " (10.3 x 38.1mm). Ratings: Volts -- 250Vac (or less) Amps -- 210-30A IR -- 10kA @ 125Vac (210-30A) -- 35A (210-1A @ 250Vac) -- 100A (112-3A @ 250Vac) -- 200A (4-10A @ 250Vac) Features and Benefits -- 750A (12A- 15A @ 250Vac) * Low cost supplemental protection of 600V -- 200A (20-30A @ 250Vac) or less non-inductive circuits. Agency Information: CE, Std. 248-14, * Upgrade with LP-CC product to reduce UL 0-15/250V, Guide JDYX, File E19180 SKU investment and minimize potential CSA Certified, 0-15/250V, Class arc-flash hazards. 1422-01, File 53787. Typical Applications Features and Benefits * Control Circuits * Low cost supplemental protection of * Lighting Circuit Protection 125V and 250V non-inductive circuits. * Meter Circuits * Upgrade with LP-CC product to reduce Catalog Numbers (Amps) SKU investment and minimize potential 600Vac - UL Listed and CSA arc-flash hazards. (and minimize KTK- KTK- KTK-4 KTK-12 KTK-50* potential for misapplying fuse.) KTK- KTK-1 KTK-5 KTK-15 1 10 1 Typical Applications * General Purpose Circuits * Lighting Circuit Protection * Meter Circuits Catalog Numbers (Amps) 3 4 8 KTK- 210 KTK-1- 14 KTK-6 KTK- 14 KTK-1- 12 KTK-7 KTK-20 KTK-25 KTK- 310 KTK-2 KTK-7- 12 KTK-30 KTK- 410 KTK-2- 12 KTK-8 KTK-35* KTK- 12 KTK-3 KTK-9 KTK-40* KTK- 610 KTK-3- 12 KTK-10 KTK-45* *Rated for no more than 24A continuous. Low Voltage Supplementary Fuses KTK Features and Benefits * Full range, fast-acting, 600Vac/dc midget fuse. * Minimum interrupting rating or 200% rated current at 600Vdc. Typical Applications * DC Control Circuits Requiring Fast-Acting Fuses. * Solar power energy sources. Catalog Numbers (Amps) - DCM DCM-110 DCM-1 DCM-5 DCM-15 DCM- 18 DCM-1- 14 DCM-6 DCM-20 DCM- 210 DCM-1- 12 DCM-7 DCM-25 DCM- 4 DCM-2 DCM-8 DCM-30 BAF-210 BAF-2 BAF-8 BAF-14 BAF-2-12 BAF-9 DCM- 310 DCM-2- 12 DCM-9 BAF-12 BAF-3 BAF-10 DCM- 12 DCM-3 DCM-10 BAF-610 BAF-4 BAF-12 DCM- 34 DCM-4 DCM-12 BAF-810 BAF-5 BAF-15 BAF-1 BAF-6 BAF-20 BAF-1-12 BAF-6-14 BAF-25 BAF-1- 10 8 BAF-7 1 Catalog Numbers (Amps) - KLM BAF-30 *All have interrupting rating of 10,000A at 125V. KLM-110 KLM- 34 KLM-5 KLM-20 KLM- 18 KLM-1 KLM-6 KLM-25 KLM- 210 KLM-1- 12 KLM-8 KLM-30 KLM- 4 KLM-2 KLM-10 KLM- 310 KLM-3 KLM-12 KLM- 12 KLM-4 KLM-15 1 For superior electrical protection, Cooper Bussmann recommends upgrading BAF and fuse applications to Low-Peak LP-CC fuses See page 17. For superior electrical protection, Cooper Bussmann recommends upgrading KTK fuse applications to Low-Peak LP-CC fuses See page 17. Data Sheet: 2011 (0-30) Data Sheet: 1011 Data Sheet: DCM 2038 KLM 2020 Recommended fuse blocks/fuse holders for 1332" x 1 12" fuses * See page 44 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 47 Low Voltage Supplementary Fuses Fuses for Solar Panel Applications Dimensions - (mm) PV Specifications Class: gPV Description: A range of fuses specifically designed for the protection and isolation of photovoltaic strings. Dimensions: 1332" x 112" (10.3 x 38.1mm). Ratings: Volts -- 1000Vdc Amps -- 1-15A IR -- 33kAdc IR (Min) -- 1.3 x In Agency Information: UL Pending, CE, IEC 60269. Features and Benefits * Capable of interrupting low over currents associated with faulted PV strings. * High DC voltage rating. * Variety of mounting options for flexibility. Catalog Numbers (Amps) PV-1A10F PV-3A10F PV-5A10F PV-8A10F PV-12A10F PV-2A10F PV-4A10F PV-6A10F PV-10A10F PV-15A10F For bolt-on tabs, replace `F' with `-T' For PCB mounting, replace `F' with `-1P' or `-2P' Time-Current Characteristic Curves--Average Melt Data Sheet: 720110 48 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage Supplementary Fuses 13 32" x 1 12" Time-delay Fuses FNQ Specifications Class: Supplemental Description: Time-delay supplementary fuse. Dimensions: 1332" x 112" (10.3 x 38.1mm). Ratings: Volts -- 250Vac (or less) Amps -- 110-30A IR -- 35A (110-1A @ 250Vac) -- 100A (118-312A @ 250Vac) -- 200A (4-10A @ 250Vac) -- 10kA (110-10A @ 125Vac) -- 10kA (12-30A @ 250Vac) Agency Information: CE, Std. 248-14, UL Listed, 0-30/250Vac; File E19180, Guide JDYX, CSA Certified, 1-30/250Vac; Class 1422-01, File 53787. Specifications Class: Supplemental Description: Time-delay supplementary fuse. Dimensions: 1332" x 112" (10.3 x 38.1mm). Ratings: Volts -- 500Vac (or less) Amps -- 110-30A IR -- 10kA RMS Sym. Agency Information: CE, Std. 248-14, UL Listed, Guide JDYX, File E19180 CSA Certified, Class 1422-01, File 53787. Features and Benefits * Low cost supplemental protection of 125V and 250V inductive circuits. Typical Applications * General Purpose Circuits * Lighting Circuit Protection * Meter Circuits * Upgrading to LP-CC product will reduce SKU investment and minimize potential for misapplying fuse. Features and Benefits * Low cost supplemental protection of transformers and relays at 500V or less. Typical Applications * Control Transformer 480V Primary Protection * Lighting Circuit Protection * Meter Circuits Catalog Numbers (Amps) FNQ-110 FNQ-410 FNQ-1-12 FNQ-3-12 FNQ-7 FNQ-18 FNQ-12 FNQ-1-610 FNQ-4 FNQ-8 FNQ-25 FNQ-15100 FNQ-610 FNQ-2 FNQ-4-12 FNQ-9 FNQ-30 FNQ-316 FNQ-810 FNQ-2-14 FNQ-5 FNQ-10 FNQ- 10 FNQ-1 FNQ-2-12 FNQ-5-610 FNQ-12 FNQ-14 FNQ-1-18 FNQ-3 FNQ-6 FNQ-14 FNQ-310 FNQ-1-14 FNQ-3-210 FNQ-6-14 FNQ-15 2 FNQ-20 Catalog Numbers (Amps) FNM-110 FNM-12 FNM-1-12 FNM-3 FNM- 8 FNM- 10 FNM-1- 10 FNM-3- 10 FNM-6- 4 FNM-20 FNM-15100 FNM-34 FNM-1-810 FNM-3-12 FNM-7 FNM-25 FNM-210 FNM-1 FNM-2 FNM-4 FNM-8 FNM-30 FNM-14 FNM-1-18 FNM-2-14 FNM-4-12 FNM-9 FNM-310 FNM-1-14 FNM-2-12 FNM-5 FNM-10 FNM- 10 FNM-1- 10 FNM-2-810 FNM-5-610 FNM-12 1 4 6 6 4 FNM-6 2 FNM-15 1 For superior electrical protection, Cooper Bussmann recommends upgrading FNM and FNQ fuse applications to Low-Peak LP-CC fuses See page 17. Recommended fuse blocks and fuse holders for 32" x 1 12" fuses 13 * See page 44 Data Sheet: 2028 Data Sheet: 1012 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 49 Low Voltage Supplementary Fuses FNM Low Voltage Supplementary Fuses 13 32" x 1 38" Fast-acting Fuses BBS KTQ Specifications Class: Supplemental Description: Fast-acting supplementary fuse. Dimensions: 1332" x 138" (10.3 x 34.9mm). Construction: Fiber cartridge. Ratings: Volts -- 600Vac (110-5A) -- 250Vac (6 - 10A) -- 48Vac (12-30A) Amps -- 110-30A IR -- 10kA RMS Sym. Agency Information: CE, Std. 248-14, UL Listed, 0-5A/600V, Guide JDYX, File E19180, CSA Certified, 0-5A/600V, Class 1422-01, File 53787. Specifications Class: Supplemental Description: Fast-acting supplementary fuse. Dimensions: 1332" x 138" (10.3 x 34.9mm). Construction: Fiber cartridge. Ratings: Volts -- 600Vac Amps -- 1-6A IR -- 10kA RMS Sym. Agency Information: CE, Std. 248-14, UL Recognized, 4-6A, Guide JDYX2, File E19180. Features and Benefits * Low cost supplemental protection of non-inductive circuits * Reduced interchangeability with other supplemental fuses minimizes misapplication Typical Applications * Control Circuits * Lighting Ballasts * Meter Circuits Typical Applications * Control Circuits * Lighting Ballasts * Meter Circuits Catalog Numbers (Amps) (600Vac) Catalog Numbers (Amps) BBS-110 BBS-810 BBS-4 BBS-15 BBS- 10 BBS-1 BBS-5 BBS-20 BBS-14 BBS-1-12 BBS-6 BBS-25 BBS-410 BBS-1-610 BBS-7 BBS-30 BBS-12 BBS-1-810 BBS-8 BBS-610 BBS-2 BBS-10 BBS-34 BBS-3 BBS-12 2 Features and Benefits * Low cost supplemental protection of non-inductive circuits * Rated for application in circuits at 600V or less. * Reduced interchangeability with other supplemental fuses minimizes misapplication KTQ-1 KTQ-3 KTQ-1-610 KTQ-4 KTQ-2 KTQ-5 KTQ-6 Recommended fuse blocks/fuse holders for 1332" x 1 38" fuses * Page 45 Data Sheet: 2010 (0-30A) 50 Data Sheet: 2045 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage Supplementary Fuses Pin Indication Fuses MIC & MIN FNA GLD Specifications Class: Supplemental Description: Fastacting, pin indication fuse. Dimensions: 13 32" x 1 12" (10.3 x 38.1mm) 5AG. Ratings: Volts -- 250Vac (1-15A) -- 32V (20-30A) Amps -- 1-30A IR -- 35A (1A @250Vac) -- 100A (2-3A @250Vac) -- 200A (5-10A @250Vac) -- 750A (15A @250Vac) -- 10kA (20-30A @32V) -- 35A (1A @250Vac) Agency Information: CE, Std. 248-14, MIC--0-15A UL Listed, 125Vac/10kA IR Guide JDYX, File E19180, MIN--1-5A CSA Certified, Class 1422-01, File 53787. Specifications Class: Supplemental Description: Time-delay, pin indication fuse. Dimensions: 1332" x 1 12" (10.3 x 38.1mm). Ratings: Volts -- 250Vac (110-810A) -- 125Vac (1-15A) -- 32V (20-30A) Amps -- 110-30A IR -- 35A (110-810A @ 250Vac) -- 10kA (110-15A @ 125Vac) -- 1kA (20-30A @ 32V) Agency Information: CE, Std. 24814, UL Listed 110-810A, IR 35A@ 250V, IR 10kA@ 125V , 1-15A, IR 10kA@ 125V, Guide JDYX, File 19180, CSA Certified, 0-810A/250V, 1-10A/125V, Class 1422-01, File 53787. Specifications Class: Supplemental Description: Fast-acting, pin indication fuse. Dimensions: 14" x 1 14" (6.6 x 31.7mm) 3AG. Ratings: Volts -- See Agency Info below 1 Amps -- 2-15A IR -- See Agency Info below Agency Information: CE, Std. 24814, UL Listed, 0-5A/125Vac, 10,000 AIC, Guide JDYX, File E19180, UL Recognized, 6A/125Vac, 1000AIC 8-15A/50Vac/dc, 300 AIC Guide JDYX2, File E19180, CSA Certified: 0-5A/125Vac, 10,000 AIC Class 1422-01, File 53787. Features and Benefits * Type GBA has a "red" pin indicator providing visual identification of failed circuits, resulting in faster troubleshooting (reduced circuit downtime). * Type GLD has a plated pin to activate transmitting a electrical signal to indicate the location of opened circuits, resulting in reduced downtime. Typical Applications * Control Circuits * Electronic Circuits GLD Catalog Numbers (Amps) GLD-12 GLD-2 GLD-6 GLD-34 GLD-3 GLD-10 GLD-1 GLD-4 GLD-12 GLD-1-12 GLD-5 GLD-15 GBA Catalog Numbers (Amps) GBA-12 GBA-2 GBA-8 GBA-34 GBA-3 GBA-10 GBA-1 GBA-4 GBA-15 GBA-1-12 GBA-5 Features and Benefits * Type MIN has a "red" pin indicator providing visual identification of failed circuits, resulting in faster trouble shooting (reduced circuit downtime). * Type MIC has silver-plated pin transmitting an electrical signal indicating location of a failed circuit, resulting in faster troubleshooting (reduced circuit downtime). Typical Applications * Control Circuits * PLC Circuits * Electronic Circuits MIC Catalog Numbers (Amps) MIC-1 MIC-5 MIC-20 MIC-2 MIC-10 MIC-25 MIC-3 MIC-15 MIC-30 Features and Benefits * FNA has a pin indicator providing visual identification of failed circuits, resulting in reduced circuit downtime. * Time-delay response allows close sizing on control transformers and relays Typical Applications * Control Circuits * Electronic Circuits Catalog Numbers (Amps) FNA-110 FNA-18 FNA-15100 FNA-210 FNA-14 FNA-310 FNA-410 FNA-12 FNA-610 FNA-34 FNA-810 FNA-1 FNA-1-18 FNA-1-14 FNA-1-410 FNA-1-12 FNA-1-610 FNA-1-810 FNA-2 FNA-2-14 FNA-2-12 FNA-2-810 FNA-3 FNA-3-210 FNA-3-12 FNA-4 FNA-4-12 FNA-5 FNA-5-610 FNA-6 FNA-6-14 FNA-7 FNA-8 FNA-9 FNA-10 FNA-12* FNA-15* FNA-20* FNA-25* FNA-30 *12-30A versions are dual-tube construction MIN Catalog Numbers (Amps) MIN-1 MIN-5 MIN-20 MIN-2 MIN-10 MIN-25 MIN-3 MIN-15 MIN-30 Recommended fuse blocks/fuse holders for 14" x 1 14" indicating fuses Recommended signal block for 13 32" x 1 12" indicating fuses Recommended signal block for * Page 45 * Page 45 * Page 45 Data Sheet: 2012 Data Sheet: 2047 32" x 1 12" indicating fuses 13 Data Sheet: 2029 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 51 Low Voltage Supplementary Fuses GBA Low Voltage Supplementary Fuses Pin Indication Fuse and Actuator, and Limiters ANN & ANL Limiters Specifications Description: Circuit limiters. ANN: Very fast-acting limiter. ANL: Time-delay limiter. Dimensions: 78" x 3 316" (22.2 x 81.0mm). Ratings: ANN: Volts -- 125Vac -- 80Vdc Amps -- 10-800A IR -- 2500A @ 125Vac -- 2700A @ 80Vdc ANL: Volts -- 80Vdc Amps -- 35-750A IR -- 2700A @ 80Vdc -- 6000A @ 32Vdc Agency Information: ANN: 35-400A @ 125Vac, IR=2500A and 500A @ 80Vdc, IR=2700A: UL Recognized Guide JFHR2, File E56412; CSA Certified Class 1422-30, File 53787, CE for 35-400A. ANL: UL Recognized, CSA Certified, 35-750A @ 80Vdc, IR = 2700A, Guide JFHR2, File E56412, Class 1422-30, File 53787, SAE J1171. Features and Benefits * Fast-acting circuit protection (ANN). * Time-delay sizing for inductive circuits (ANL). * Small footprint saves space. * Window shows limiter status. Typical Applications * Fork lifts, Marine, Aviation ANN-10 ANN-90 ANN-225 ANN-400 ANN-35 ANN-100 ANN-250 ANN-500 ANN-40 ANN-125 ANN-275 ANN-600 ANN-50 ANN-150 ANN-300 ANN-700 ANN-60 ANN-175 ANN-325 ANN-800 ANN-80 ANN-200 ANN-350 ANL Catalog Numbers (Amps) ANL-125 ANL-130 ANL-150 ANL-175 ANL-200 ANL-225 ANL-250 ANL-275 ANL-300 ANL-325 ANL-350 ANL-400 KAZ Specifications Class: Supplemental Description: Non timedelay pin indication fuse. Dimensions: 1332" x 2" (10.3 x 50.8mm). Ratings: Volts -- 600Vac Amps -- 1-12A IR -- 200kA Features and Benefits * Type MIS has a pin indicator providing visual identification of failed circuits, resulting in faster troubleshooting (reduced circuit downtime). * Type MIS can be used in circuits rated 600V or less. * Type MIS has an interrupting rating of 200kA. Typical Applications * 480V Control Circuits * PLC Circuits Catalog Numbers (Amps) MIS-1 MIS-2 MIS-3 MIS-4 MIS-5 MIS-8 Test Specifications MIS-10 MIS-12 ANL-500 ANL-600 ANL-675 ANL-750 Specifications Description: Non-Fuse actuator. Dimensions: 1332" x 2" (10.3 x 50.8mm). Ratings: Volts -- 600Vac Amps -- N/A IR -- 200kA Agency Information: CE, UL Listed, Guide JDVS, File E58836. Features and Benefits * Bussmann signal blocks 2778, 2837 or 2838 with KAZ actuators mounted in parallel with fuses having a rating of 50A or larger to provide blown fuse dropout of shunttrip fused switches. * Type KAZ can be used in circuits rated 600V or less. * Type KAZ has an interrupting rating of 200kA. Typical Applications * Large, Shunt-Trip Fused Switches * Fuse Protected Circuits Rated 50A or Larger With Shunt-Trip Devices. Catalog Number: KAZ Fuse Load All 110% Opening Time 0 4 hrs. (min.) 1-5A 150% 0 6 min. (max.) 6-12A 150% 12 min. (max.) Recommended signal block for 13 32" x 2" indicating fuses ANN Catalog Numbers (Amps) ANL-35 ANL-40 ANL-50 ANL-60 ANL-80 ANL-100 MIS * Page 45 Recommended signal block for 13 32" x 2" indicating fuses * Page 45 Data Sheet: 2021 4164 & 4164-FR Limiter Blocks Specifications Description: Limiter fuse blocks for ANL & ANN. * 4164 furnished with nylon inserted locknuts * 4164-FR furnished with standard hex nuts Dimensions: Length: 3.38 Width: 0.95 Height: 1.62 Studs center to center: 2.43 Ratings: Volts -- 125Vac -- 80Vdc Amps -- 10-800A Poles: 1 - stud terminal Data Sheets: 2023 (ANN), 2024 (ANL) 52 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage Supplementary Fuses In-line Size Rejecting Fuses and Fuse Holders GMQ Specifications Class: Supplemental Description: Fast-acting, size-rejecting in-line fuse. Construction: Glass tube. Ratings: Volts -- 300Vac (or less) Amps -- 1-10A IR -- 10kA Agency Information: CE, Std. 248-14, UL Listed (Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File 53787). Specifications Features and Benefits * In-Line, fast-acting circuit protection. * Rejection feature prevents overfusing. Class: Supplemental Description: Time-delay, size-rejecting in-line fuse. Construction: Ceramic tube. Ratings: Volts -- 300Vac (or less) Amps -- 12-614A IR -- 10kA Agency Information: CE, Std. 248-14, UL Listed (Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File 53787) Features and Benefits * In-line, fast-acting circuit protection. * Rejection feature prevents overfusing. Typical Applications * In-line Lighting Ballast Protection Typical Applications * In-Line Lighting Ballast Protection Catalog Numbers (Amps) and Rejection Holders Fuse GLQ-1 GLQ-1-12 GLQ-1-61 0 GLQ-2 GLQ-2 -12 Holder1, 2 HLQ-1-61 0 HLQ-1-61 0 HLQ-1-61 0 HLQ-3 -21 0 HLQ-3 -21 0 Fuse GLQ-3 GLQ-4 GLQ-5 GLQ-9 GLQ-10 Holder1, 2 HLQ-3 -21 0 HLQ-5 HLQ-5 HLQ-10 HLQ-10 Catalog Numbers (Amps) and Rejection Holders Fuse Holders3, 4 Fuse Holders3, 4 GMQ-12 HLQ-12 GMQ-2-12 HLQ-3 -210 GMQ-610 HLQ-1-610 GMQ-3 HLQ-3 -210 GMQ-810 HLQ-1-610 GMQ-3 -210 HLQ-3 -210 GMQ-1 HLQ-1-610 GMQ-4 HLQ-5 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 10A, 300Vac. 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043"to 0.062" or #4909 for thickness 0.030" to 0.042". * Do not put tension on line (rear) terminal of fuse holder. GMQ-1-14 HLQ-1-610 GMQ-6 HLQ-8 GMQ-1-610 HLQ-1-610 GMQ-6 -14 GMQ-2 HLQ-3 -210 Data Sheet: 2033 Data Sheet: 2030 3) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 10A, 300Vac. 4) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043"to 0.062" or #4909 for thickness 0.030" to 0.042" * Do not put tension on line (rear) terminal of fuse holder. 3 HLQ Fuse Holders for both GLQ & GMQ fuses. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 53 Low Voltage Supplementary Fuses GLQ Low Voltage Supplementary Fuses In-line Non-rejecting Fuses and Fuse Holders GLR GMF Specifications Class: Supplemental Description: Fast-acting, non-rejection, in-line fuse. Construction: Glass tube. Ratings: Volts -- 300Vac (or less) Amps -- 316-15A IR -- 10kA Agency Information: CE, Std. 248-14, UL Listed, 015A/300Vac (Guide JDYX, File E19180), CSA Certified, 0-10A/300V (Class 1422-01, File 53787). GRF Features and Benefits * In-line, fast-acting circuit protection. Features and Benefits * In-line, time-delay circuits protection. Typical Applications * In-Line Lighting Ballast Protection Catalog Numbers (Amps) and Non-Rejection Holders Fuse GLR-31 6 GLR-12 GLR-1 GLR-1-12 GLR-1 -61 0 GLR-2 GLR-3 GLR-4 Holder1, 2* HLR HLR HLR HLR HLR HLR HLR HLR Fuse GLR-5 GLR-6 GLR-7 GLR-8 GLR-9 GLR-10 GLR-12 GLR-15 Holder1, 2* HLR HLR HLR HLR HLR HLR HLR HLR-2A 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 12A, 300Vac. 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043"to 0.062" or #4909 for thickness 0.030" to 0.042". * For two leads (one each for line and loadside) order HLR-2A, 15A, 300V * * Specifications Class: Supplemental Description: Time-delay, non-rejection, in-line fuse. Construction: Glass tube. Ratings: Volts -- 300Vac (or less) Amps -- 310-10A IR -- 10kA Agency Information: CE, Std. 248-14 0-10A, UL Listed (Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File 53787). An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235. Do not put tension on line (rear) terminal of fuse holder. Typical Applications * In-Line Lighting Ballast Protection Catalog Numbers (-Amps) and Non-Rejection Holders Fuse GMF-31 0 GMF-12 GMF-61 0 GMF-81 0 GMF-1 GMF-1-14 GMF-1-61 0 GMF-2 GMF-2 -12 GMF-2 -81 0 Fuse Holder Holder3, 4* HLR HLR HLR HLR HLR HLR HLR HLR HLR *For two leads order HLR-2A, 15A, 300V * An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235. Do not put tension on line (rear) terminal of fuse holder. Data Sheet: 2031 HLR-2A 54 Fuse GMF-3 GMF-3 -21 0 GMF-4 GMF-5 GMF-6 -14 GMF-10 GRF-7 GRF-8 GRF-10 3) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 12A, 300Vac. 4) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043"to 0.062" or #4909 for thickness 0.030" to 0.042". * Data Sheet: 2032 Holder3, 4* HLR HLR HLR HLR HLR HLR HLR HLR HLR HLR HLR Fuse Holder For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Low Voltage Supplementary Fuses Automotive Blade-type Fuses ATC(R) fuse ATM Fuse MAX Maxi-Fuse(R) Low Voltage Supplementary Fuses Available With Indication Available With Indication (Actual Size) Available With Indication (Actual Size) (Actual Size) Specifications Description: Fast-acting blade fuse. Construction: Colored plastic housing with zinc fuse element. Ratings: Volts -- 32Vdc Amps -- 1-40A IR -- 1000A Agency Information: UL Recognized, (3-40A) (Guide JFHR2, File E56412), SAE Standard J1284. Features and Benefits * Color coded plastic housing for easy identification of fuse ratings Typical Applications * Automotive Specifications Description: Fast-acting blade fuse. Construction: Colored plastic housing with zinc fuse element. Ratings: Volts -- 32Vdc Amps -- 2-30A IR -- 1000A Features and Benefits * Color coded plastic housing for easy identification of fuse ratings Typical Applications * Automotive Features and Benefits * Color coded plastic housing for easy identification of fuse ratings Typical Applications * Automotive Catalog Numbers (Amps) Catalog Numbers (Amps) Part No. Non-Indicating Indicating Low-Profile ATM-2 Catalog Numbers (Amps) ATM-3 Indicating ATC-1 Black ATC-2 ATC-3 Color Gray ATC-3ID ATC-4 Color Gray ATM-3ID Violet ATM-4 Catalog No. Non-Indicating Pink ATM-5 ATM-5ID ATM-5LP Tan ATM-7-1/2 ATM-7-1/2ID ATM-7-1/2LP Brown ATM-10 ATM-15 ATM-10ID ATM-15ID ATM-10LP ATM-15LP Red Blue Violet ATM-20 ATM-20ID ATM-20LP Yellow Pink ATM-25 ATM-25ID ATM-25LP Clear ATC-5 ATC-5ID Tan ATC-7-1/2 ATC-7-1/2ID Brown ATC-10 ATC-10ID Red ATC-15 ATC-15ID Blue ATC-20 ATC-20ID Yellow ATC-25 ATC-25ID Clear ATC-30 ATC-30ID Green ATC-35 ATC-35ID Blue-Green ATC-40 ATC-40ID Orange Recommended in-line fuse holder for blade type fuses Specifications Description: Fast-acting blade fuse. Construction: Colored plastic housing with zinc fuse element. Ratings: Volts -- 32Vdc Amps -- 20-80A IR -- 1000A ATM-30 ATM-30ID ATM-30LP Catalog No. Non-Indicating Indicating Color MAX-20 MAX-20ID Yellow MAX-30ID Green MAX-25 MAX-30 Gray MAX-35 Brown MAX-40 MAX-40ID Orange MAX-50 MAX-50ID Red MAX-60 MAX-60ID Blue MAX-70 MAX-70ID Tan MAX-80 MAX-80ID Clear MAX-100ID Purple Green Recommended in-line fuse holder for blade type fuses Recommended in-line fuse holder for blade type fuses * Page 56 * Page 56 * Page 56 Data Sheet: 2009 Data Sheet: 2048 Data Sheet: 2049 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 55 Low Voltage Supplementary Fuses Automotive Blade-type Fuse Holders HHC, HHD, HHF, HHG & ATC-FHID HHL, HHM & ATM-FHID HHX LED Indicator LED Indicator easy IDTM LED Indicating Holder easy IDTM LED Indicating Holder Specifications Description: In-line fuse holders for ATC(R) Blade-Type fuses. Dimensions: See Dimensions illustration. Ratings: Volts: -- 32Vdc Amps:-- 80% continuous of fuse rating. See Catalog Numbers table for individual fuses sizes. Specifications Description: In-line fuse holders for ATM Fuses. Ratings: Volts: -- 32Vdc Amps: -- 80% continuous of fuse rating. See Catalog Numbers table for individual fuses sizes. Catalog Numbers Catalog Numbers Catalog Fuse Holder Numbers Description HHL Black w/ cover Catalog Numbers HHC HHD HHD-C HHF HHG ATC-FHID Fuse Holder Description Yellow Black HHD Cover only Black w/ cover Black w/ cover Indicating Holder Black w/ cover Fuse Amps 1-20 1-30 -- 1-20 1-30 Electrical Connection #16 black leadwire #12 yellow leadwire Clear polycarbonate #16 yellow leadwire #12 yellow leadwire 1-20 #16 black leadwire Bulk Products (Quantity - 1000 Pieces) Catalog Fuse Holder Fuse Electrical Numbers Description Amps Connection BK/HHC-R Yellow 1-20 #16 red leadwire BK/HHF-B Black w/ cover 1-20 #16 black leadwire A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended. HHC & HHD Dimensions - in Fuse Electrical Amps Connection 2-20 #16 black leadwire, 4" length stripped to HHL-B Black - body only 2-20 #16 black leadwire, 4" length stripped to HHM Black w/ cover 2-30 #12 red leadwire, 4" length stripped to HHM-B Black - body only 2-30 #12 red leadwire, 4" length stripped to HHM-C Black - cover only -- -- Indicating Holder ATM-FHID 1-20 #16 black leadwire Black w/ cover Specifications Description: In-line fuse holders for MAXI(R) Fuses. Ratings: Volts: -- 32Vdc Amps: -- 80% continuous of fuse rating. See Catalog Numbers table for individual fuses sizes. Catalog Numbers Catalog Fuse Holder Numbers Description HHX Black w/ cover Fuse Amps 20-60 /4" HHX-B Black - body only 20-60 /4" HHX-C Black cover only -- 1 1 /4" 1 /4" 1 A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended. Dimensions - in Bulk Products (Quantity - 1000 Pieces) Catalog Fuse Holder Fuse Electrical Numbers Description Amps Connection BK/HHL-R Black - w/cover 2-20 #16 red leadwire, 4" length stripped to 1/4" BK/HHL-B Black - body only 2-20 #16 black leadwire, 4" length stripped to 1/4" 3.35" 6.70" .265" DIA. HOLE A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended. HHL & HHM Dimensions - in 1.56" 0.91" 0.5" .59" 0.38" 0.30" .25" .25" 4.75" 4.75" .41" 0.25" 4.0" + 0.25" Data Sheet: 2107 56 1.125" 4.0" + 0.25" Data Sheet: 2128 6.70" 1.37" 0.78" 0.364" Electrical Connection #6 red leadwire, 5" with blunt ends #6 red leadwire, 5" with blunt ends -- Data Sheet: 2129 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Electronic fuses Section Contents Page 5 x 15mm ferrule fuses . . . . . . . . . . . . . . . . . . . . . . 58 5 x 20mm European (IEC) ferrule fuses . . . . . . . . 59-60 5 x 20mm North American (UL) ferrule fuses . . . . . 61 4 Dia. x 8 to 1 length ferrule fuses . . . . . . . . . . . 62 1 5 4 Dia. x 1 14 length fast-acting ferrule fuses . . . . . . 63 1 PCB mount fuse holders . . . . . . . . . . . . . . . . . . . 65-66 PCB fuseclips for 5mm dia. fuses . . . . . . . . . . . . . . 67 PCB fuseclips for 14 dia. fuses . . . . . . . . . . . . . . . . (R) PCB fuseclips for 32 dia. and ATC fuses . . . . . . . 13 68 69 PCB fuseclips for 4, 32, 32 & 16 fuses . . . . . . . . 70 1 9 13 9 57 Electronic Fuses 4 Dia. x 1 14 length time-delay ferrule fuses . . . . . . 64 1 Electronic -- PCB & Small Dimension Fuses 5 x 15mm Ferrule Fuses C515 (axial leads) C518 (axial leads) C517 (axial leads) C519 C520 Specifications Description: Time-delay fuse. Dimensions: 5 x 15mm (0.197" X 0.591"). Construction: Glass tube. Ratings: Volts -- 125Vac (3.5-7A) -- 250Vac (125mA-3A) Amps -- 125mA-7A IR -- 25A (350mA @ 600Vac) -- 35A (125mA-1A @ 250Vac) -- 100A (1.25-3A @ 250Vac) -- 400A (3.5-7A @ 125Vac) -- 10kA (125mA-3A @ 125Vac) Agency Information: CE, UL Listed File E19180, Guide JDYX 125mA-250mA and 375mA-3A, UL Recognized, File E19180, Guide JDYX2, 350mA and 3.5A-7A, CSA Certification File 53787, Class 1422-01, 125mA-250mA and 375mA-3A. Specifications Description: Fast-acting fuse. Dimensions: 5 x 15mm (0.197" X 0.591"). Construction: Glass tube. Ratings: Volts -- 250Vac Amps -- 100mA-5A IR -- 35A (100mA-750mA @ 250Vac) -- 10kA (100mA-5A @ 125Vac) -- 100A (1.5-3.5A @ 250Vac) -- 200A (4-5A @ 250Vac) Agency Information: CE, UL Recognized File E19180, Guide JDYX2CSA Certification File 53787, Class 1422-01. Specifications Description: Fast-acting fuse. Construction: Glass tube. Ratings: Volts -- 350Vac* Amps -- 3A IR -- 100A @ 350Vac -- 100A @ 250Vac -- 10kA @ 125Vac Features and Benefits * Time-delay for closer sizing on inductive circuits. Typical Application * Electronic Circuits * Printed Circuit Boards C515-2.5-R C515-3-R C515-3.5-R C515-4-R C515-5-R C515-6-R C515-7-R Typical Applications * Electronic Circuits * Printed Circuit Boards * Electronic Ballast Protection Catalog Number (Amps) With Axial Leads C517-3-R Typical Applications * Electronic Circuits * Printed Circuit Boards With Axial Leads C518-100-R C518-750-R C518-125-R C518-2-R C518-250-R C518-2.5-R C518-375-R C518-3-R C518-500-R C518-3.5-R Without Axial Leads C520-100-R C520-750-R C520-125-R C520-1.5-R C520-250-R C520-2-R C520-375-R C520-2.5-R C520-500-R C520-3-R C518-4-R C518-5-R C520-3.5-R C520-4-R C520-5-R C519-2.25-R C519-2.5-R C519-3-R C519-3.5-R C519-4-R C519-5-R Data Sheet: 2006 (C515) & 2007 (C519) 58 Agency Information: CE, UL Listing File E19180, Guide JDYX, CSA Certification File 53787, Class 1422-01, UL Recognized, File E19180, Guide JDYX2. * Small footprint saves space in equipment. * Fast-acting for maximum component protection. * 350Vac rating for 277V ballast circuit protection. Catalog Numbers (Amps) Catalog Numbers (Amps) With Axial Leads C515-125-R C515-800-R C515-250-R C515-1-R C515-350-R C515-1.25-R C515-375-R C515-1.5-R C515-500-R C515-1.6-R C515-600-R C515-2-R C515-750-R C515-2.25-R Without Axial Leads C519-125-R C519-750-R C519-250-R C519-1-R C519-350-R C519-1.25-R C519-375-R C519-1.5-R C519-500-R C519-1.6-R C519-600-R C519-2-R Features and Benefits * Small footprint saves space in equipment. * Fast-acting for maximum component protection. * Available in ferrule and axial leaded configurations *350Vac/100A is UL Recognized Data Sheet: 2026 (C518) & 2027 (C520) Data Sheet: 2025 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Electronic -- PCB & Small Dimension Fuses 5 x 20mm European (IEC) Ferrule Fuses S500-V (GDB-V)* (axial leads) S500 (GDB)* Typical Applications * Electronic Circuits Catalog Numbers (Amps) S500-32-R S500-40-R S500-50-R S500-63-R S500-80-R S500-100-R S500-125-R S500-160-R S500-200-R S500-250-R S500-315-R S500-400-R S500-500-R S500-630-R S500-800-R S500-1-R S500-1.25-R S500-1.6-R S500-2-R S500-2.5-R S500-3.15-R S500-4-R S500-5-R S500-6.3-R S500-8-R S500-10-R 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 40 50 63 80 100 I2t 0.000047 0.00011 0.00020 0.00057 0.0012 0.003 0.005 0.008 0.016 0.028 0.058 0.018 0.018 0.035 0.067 0.60 0.84 1.6 4.2 6.1 13 22 42 69 --- Max Voltage Drop (mV) 3200 2500 2400 2000 1200 1100 1000 2000 1700 1400 1300 1100 220 220 190 200 200 190 150 150 130 130 120 120 120 120 Options Axial leads, put "V" in P/N, *When ordering GDB version, do not add "-R" suffix to part number. Data Sheet: 2052 (S500), 2015 (GDB) Typical Applications * Electronic Circuits Catalog Numbers (Amps) S501-50-R S501-63-R S501-80-R S501-100-R S501-125-R S501-160-R S501-200-R S501-250-R S501-315-R S501-400-R S501-500-R S501-630-R S501-800-R S501-1-R S501-1.25-R S501-1.6-R S501-2-R S501-2.5-R S501-3.15-R S501-4-R S501-5-R S501-6.3-R S501-8-R S501-10-R (axial leads) S505 Specifications Description: Fastacting, high-breaking capacity fuse. Construction: Ceramic tube, nickel-plated brass endcaps (silverplated endcaps 50mA-400mA). Ratings: Volts -- 250Vac (or less) Amps -- 50mA-10A** IR -- 1500A @ 250Vac Agency Information: CE, cURus, SEMKO, VDE, IMQ, CCC, CSA, BSI. See data sheet for complete agency information. Not all approvals apply to all ratings. Features and Benefits * Fast-acting for maximum protection. * High break capacity for use in higher fault energy electronic circuitry. * Conforming to IEC standards. Catalog Numbers S505-V Specifications Description: Timedelay, high-breaking capacity fuse. Construction: Ceramic tube, silverplated brass endcaps. Ratings: Volts -- 250Vac (or less) Amps -- 500mA-12A IR -- 1500A @ 250Vac Agency Information: UL, CSA, SEMKO, VDE, BSI, IMQ, PSE/JET, CCC, EK, FIMKO. See data sheet for complete agency information. Not all approvals apply to all ratings. Features and Benefits * Time-delay performance ideal for inductive circuits. * Conforming to IEC standards. Typical Applications * Electronic Circuits Catalog Numbers (Amps) Catalog Numbers I2t Typical Voltage Drop (mV) 0.0017 0.0005 0.0011 0.0018 0.0037 0.008 0.020 0.027 0.010 0.018 0.038 0.064 0.097 0.146 0.313 0.748 2.0 3.9 8.1 14 25 48 N/A N/A 9000 3300 2600 2300 1900 1600 1350 1300 1400 1200 1050 1200 490 330 297 239 205 190 160 160 155 150 N/A N/A Typical I2t Max Voltage Drop (mV) S505-500-R 0.188* 295 S505-800-R 0.632* 189 S505-1-R 1.28 152.5 S505-1.25-R 2.22 150 S505-1.6-R 6.78 125 S505-2-R 9.60 118.5 S505-2.5-R 16.60 115 S505-3.15-R 36.60 102.5 S505-4-R 38.45* 86.5 S505-5-R 71.30* 77.5 S505-6.3-R 197 75 S505-8-R 311 75 S505-10-R 397 72 S505-12-R 713.7* 77 *The typical I2t value was measured at 10 times of rated current under DC Options Axial leads, put "V" in P/N. Options Axial leads, put "V" in P/N. *When ordering GDA version, do not add "-R" suffix to part number. **GDA is not available above 6.3A. Data Sheet: 2051 (S501), 2014 (GDA) Data Sheet: 2037 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 59 Electronic Fuses Features and Benefits * Fast-acting for maximum protection, conforms to IEC 60127-2 (160mA-10A). IR (Amps) (axial leads) S501 (GDA)* Specifications Description: Fastacting, low-breaking capacity fuse. Construction: Glass tube, nickelplated brass endcaps (silver-plated endcaps, 32-125mA). Ratings: Volts -- 250Vac (or less) Amps -- 32mA-10A IR -- See catalog table Agency Information: CE, cURus, CSA, SEMKO, VDE, BSI, IMQ, CCC. See data sheet for complete agency information. Not all approvals apply to all ratings. Catalog Numbers S501-V (GDA-V)* Electronic -- PCB & Small Dimension Fuses 5 x 20mm European (IEC) Ferrule Fuses S506-V (GDC-V)* (axial leads) S506 (GDC)* Specifications Description: Timedelay, low-breaking capacity fuse. Construction: Glass tube, nickel-plated brass endcaps. Ratings: Volts -- 250Vac (or less) Amps -- 32mA-15A** IR -- 35A @ 250Vac Agency Information: UR, CSA, cURus, SEMKO, VDE, BSI, IMQ, PSE/JET, CCC. See data sheet for complete agency information. Not all approvals apply to all ratings. Features and Benefits * Time-delay compatibility for inductive circuits. * Conforming to IEC standards. Typical Applications * Electronic Circuits Catalog Numbers (Amps) Catalog Numbers S506-32-R S506-40-R S506-50-R S506-63-R S506-80-R S506-100-R S506-125-R S506-160-R S506-200-R S506-250-R S506-315-R S506-400-R S506-500-R S506-630-R S506-800-R S506-1-R S506-1.25-R S506-1.6-R S506-2-R S506-2.5-R S506-3.15-R S506-4-R S506-5-R S506-6.3-R S506-8-R S506-10-R S506-12.5-R S506-15-R Typical I2t 0.0051 0.0072 0.0095 0.021 0.038 0.045 0.063 0.093 0.114 0.265 0.621 0.872 0.827 1.33 2.78 6.45 10.05 21.7 31.6 59.4 96.4 71.8 142.5 237.6 255.8 450 1019.5 1091.7 Max Voltage Drop (mV) 1050 920 800 760 580 490 390 320 340 270 250 210 140 150 75 87.5 86 82 77 72.5 68.5 67 60.5 54 55 54 45 65.5 Options Axial leads, put "V" in P/N. *When ordering GDC version, do not add "-R" suffix to part number. **GDC series is not available above 6.3A. Data Sheet: 2016 (GDC), 4332 (S506) 60 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Electronic -- PCB & Small Dimension Fuses 5 x 20mm North American (UL) Ferrule Fuses GMC-V (axial leads) GMA GMC Specifications Description: Fast-acting fuse. Dimensions: 5 x 20mm (0.197" x 0.788"). Construction: Glass tube, nickel-plated brass endcaps. Ratings: Volts -- 250Vac (63mA-2.5A) -- 125Vac (3.15-15A) Amps -- 63mA-15A IR -- 35A (63mA- 1A @ 250Vac, p.f. = 0.7-0.8) -- 10kA (63mA-6A @ 125Vac, p.f. = 0.7-0.8) -- 100A (1.25-2.5A @ 250Vac, p.f. = 0.7-0.8) -- 200A (7-8A @ 125Vac, p.f. = 1.0) -- 150A (10-15A @ 125Vac, p.f. = 1.0) Agency Information: CE, Std. 248-14 UL Listed Guide JDYX, File E19180, 0-6A, UL Recognized, Guide JDYX2, File E19180, 7-15A, CSA Certified, Class 1422-01, File 53787, 0-6. Specifications Description: Medium time-delay fuse. Dimensions: 5 x 20mm (0.197" x 0.788"). Construction: Glass tube, nickel-plated brass endcaps. Ratings: Volts -- 250Vac (63mA3.15A) -- 125Vac (3.5-10A) Amps -- 63mA-10A IR -- 35A (63mA- 1A @ 250Vac, p.f. = 0.7-0.8) -- 10kA (63mA-6A @ 125Vac, p.f. = 0.7-0.8) -- 100A (1.25-3.15A @ 250Vac, p.f. = 0.7-0.8) -- 200A (6.3-10A @ 125Vac, p.f. = 1.0) Agency Information: CE, Std. 248-14, UL Listed Guide JDYX, File E19180, 06.3A, UL Recognized, Guide JDYX2, File E19180, 7-8A, CSA Certified, Class 1422-01, File 53787, 0-6.3A. Features and Benefits * Fast-acting for maximum protection. Catalog Numbers (Amps) Data Sheet: 2017 GMC-10A Features and Benefits * Conforming to UL standards. Typical Applications * Electronic Circuits GMA-V-4-R GMA-V-5-R GMA-V-6-R GMA-V-7-R GMA-V-8-R GMA-V-10-R GMA-V-15-R GMA-4-R GMA-5-R GMA-6-R GMA-7-R GMA-8-R GMA-10-R GMA-15-R With Axial Leads GMC-V-63-R GMC-V-500-R GMC-V-80-R GMC-V-600-R GMC-V-100-R GMC-V-630-R GMC-V-125-R GMC-V-750-R GMC-V-150-R GMC-V-800-R GMC-V-200-R GMC-V-1-R GMC-V-250-R GMC-V-1.25-R GMC-V-300-R GMC-V-1.5-R GMC-V-315-R GMC-V-1.6-R GMC-V-400-R GMC-V-2-R Without Axial Leads GMC-63mA GMC-500-R GMC-80mA GMC-600-R GMC-100mA GMC-630-R GMC-125mA GMC-750-R GMC-150mA GMC-800-R GMC-200mA GMC-1-R GMC-250mA GMC-1.25-R GMC-300mA GMC-1.5-R GMC-315mA GMC-1.6-R GMC-400mA GMC-2-R Data Sheet: 2018 GMD GMD Specifications Description: Timedelay fuse. Dimensions: 5 x 20mm (0.197" x 0.788"). Construction: Glass tube, nickelplated brass endcaps. Ratings: Volts -- 250Vac Amps -- 125mA-4A IR -- 10kA (125mA-3A @ 125Vac, p.f. = 0.7-0.8) -- 10kA (4A @ 125Vac, p.f. = 1.0) -- 35A (125mA-1A @ 250Vac, p.f. = 0.7-0.8) -- 100A (1.2A-3.A @ 250Vac, p.f. = 0.7-0.8) -- 200A (4A @ 250Vac, p.f. = 1.0) Agency Information: CE, UL Listed Guide JDYX, File E19180, 125mA-3A, UL Recognized, Guide JDYX2, File E19180, 4A, CSA Certified, Class 1422-01, File 53787, 0-4A, PSE/JET. File 1641-31003-1001, 1.2A-4A. Features and Benefits * Time-delay compatibility for inductive circuits. * Conforming to UL standards. Catalog Numbers (Amps) Typical Applications * Electronic Circuits With Axial Leads GMA-V-63-R GMA-V-800-R GMA-V-100-R GMA-V-1-R GMA-V-125-R GMA-V-1.25-R GMA-V-200-R GMA-V-1.5-R GMA-V-250-R GMA-V-1.6-R GMA-V-300-R GMA-V-2-R GMA-V-500-R GMA-V-2.5-R GMA-V-600-R GMA-V-3.15-R GMA-V-750-R GMA-V-3.5-R Without Axial Leads GMA-63-R GMA-800-R GMA-100-R GMA-1-R GMA-125-R GMA-1.25-R GMA-200-R GMA-1.5-R GMA-250-R GMA-1.6-R GMA-300-R GMA-2-R GMA-500-R GMA-2.5-R GMA-600-R GMA-3.15-R GMA-750-R GMA-3.5-R GMD-V (axial leads) GMC-V-2.5 GMC-V-3.15 GMC-V-3.5 GMC-V-4 GMC-V-5 GMC-V-6 GMC-V-6.3 GMC-V-7 GMC-V-8 GMC-V-10 GMC-2.5-R GMC-3.15-R GMC-3.5-R GMC-4-R GMC-5-R GMC-6-R GMC-6.3-R GMC-7-R GMC-8-R GMC-10-R Typical Applications * Electronic Circuits Catalog Numbers (Amps) With Axial Leads GMD-V-125-R GMD-V-500-R GMD-V-150-R GMD-V-600-R GMD-V-200-R GMD-V-630-R GMD-V-250-R GMD-V-750-R GMD-V-300-R GMD-V-800-R GMD-V-315-R GMD-V-1-R GMD-V-375-R GMD-V-1.2-R GMD-V-400-R GMD-V-1.25-R Without Axial Leads GMD-125-R GMD-500-R GMD-150-R GMD-600-R GMD-200-R GMD-630-R GMD-250-R GMD-750-R GMD-300-R GMD-800-R GMD-315-R GMD-1-R GMD-375-R GMD-1.2-R GMD-400-R GMD-1.25-R GMD-V-1.5-R GMD-V-1.6-R GMD-V-2-R GMD-V-2.5-R GMD-V-3-R GMD-V-4-R GMD-1.5-R GMD-1.6-R GMD-2-R GMD-2.5-R GMD-3-R GMD-4-R Data Sheet:2019 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 61 Electronic Fuses GMA-V (axial leads) Electronic -- PCB & Small Dimension Fuses 1 4" Dia. x 58" to 1" Length Ferrule Fuses AGA-V (axial leads) AGW AGX AGA Specifications Description: Fast-acting fuse. Dimensions: 14" x 78" (6.4 x 22.2mm). Construction: Glass tube. Ratings: Volts -- 32Vac Amps -- 1-30A Specifications Description: Fast-acting fuse. Dimensions: 14" x 1" (6.4 x 25.4mm). Construction: Glass tube. Ratings: Volts -- 250Vac (1200-2A) -- 125Vac (212-7A) -- 32V (8-30A) Amps -- 14-30A IR -- 35A (14-12A @ 250Vac) -- 100A (34-2A @ 250Vac) -- 10kA (14-5A @ 125Vac) -- 1000A (5-6A @ 125Vac) -- 1000A (8-30A @ 32Vac) Agency Information: CE, Std. 248-14, UL File E19180 UL Listed, Guide JDYX, 0-5A UL Recognized, Guide JDYX2, 6-20A CSA File 53787; Class 1422-01. Specifications Description: Fastacting fuse. Dimensions: 1 4" x 58" (6.4 x 15.9mm). Construction: Glass tube. Ratings: Volts -- 125Vac (or less) Amps -- 1-30A IR -- 10kA (1-112A @ 125Vac) -- 200A (2-5A @ 125Vac) -- 1000A (6-30A @ 32Vac) Agency Information: CE, Std. 24814, UL File E19180, UL Listed, Guide JDYX 0-112A UL Recognized, Guide JDYX2 2-12A. Features and Benefits * Fast-acting for maximum protection. * Size rejects insertion of other fuse types. Features and Benefits * Fast-acting for maximum protection. Typical Applications * Electronic Circuits Catalog Numbers (Amps) AGW-1 AGW-4 AGW-1- 12 AGW-5 AGW-20 AGW-2 AGW-6 AGW-25 AGW-2- 12 AGW-7-12 AGW-30 AGW-3 AGW-10 AGW-15 Features and Benefits * Size rejects insertion of other fuse types. Typical Applications * Electronic Circuits Typical Applications * Electronic Circuits Catalog Numbers (Amps) Catalog Numbers (Amps) With Axial Leads* AGX-14 AGX-1-12 AGX-310 AGX-2 AGX-8 AGX-10 AGA-V-1 AGA-V-5 AGA-V-15 AGX-38 AGX-2-12 AGX-15 AGA-V-1-12 AGA-V-6 AGA-V-20 AGX-410 AGX-3 AGX-20 AGA-V-2 AGA-V-7 AGA-V-25 AGX-12 AGX-4 AGX-25 AGA-V-2-12 AGA-V-7-12 AGA-V-30 AGX-34 AGX-5 AGX-30 AGA-V-3 AGA-V-10 AGX-1 AGX-6 AGX-1-14 AGX-7 Without Axial Leads AGA-1 AGA-5 AGA-15 AGA-1-12 AGA-6 AGA-20 AGA-2 AGA-7 AGA-25 AGA-2-12 AGA-7-12 AGA-30 AGA-3 AGA-10 *AGA-V is UL Listed 0-5A, UL Recognized 6-12A. Data Sheet: 2039 62 Data Sheet: 2040 Data Sheet: 2041 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Electronic -- PCB & Small Dimension Fuses 1 4 Dia. x 1 14 Length Fast-acting Ferrule Fuses ABC (ABC-V axial leads) GBB (GBB-V axial leads) Specifications Description: Fast-acting fuse. Dimensions: 14" x 1 14" (6.4 x 31.7mm). Construction: Glass tube with nickel-plated brass endcaps. Ratings: Volts -- 250Vac (120-10A) -- 32Vac (12-30A) Amps -- 120-30A IR -- 35A (120-1A @ 250Vac) -- 100A (114-3A @ 250Vac) -- 200A (4-10A @ 250Vac) -- 10kA (120-10A @ 125Vac) -- 1000A (12-30A @ 32Vac) Specifications Description: Fast-acting fuse. Dimensions: 1 4" x 1 14" (6.4 x 31.7mm). Construction: Ceramic tube with nickel-plated brass endcaps. Ratings: Volts -- 250Vac/125Vdc (14-15A, 20-30A)* -- 250Vac (18A) Amps -- 14-30A IR** -- 35A (14-1A @ 250Vac) -- 100A (112-3A @ 250Vac) -- 200A (4-10A @ 250Vac) -- 750A (12-15A @ 250Vac) -- 400A (18-20A @ 250Vac) -- 10kA (14-15A @ 125Vac) -- 1kA (18-30A @ 125Vac) -- 10kA (14-15, 20A @ 125Vdc) -- 400A (25-30A @ 125Vdc) -- 200A (25-30A @ 250Vac) Specifications Description: Very fast-acting fuse. Dimensions: 1 4" x 1 14" (6.4 x 31.7mm). Construction: Ceramic cartridge with nickel-plated brass endcaps. Ratings: Volts -- 250Vac/125Vdc Amps -- 1-30A IR -- 200A @ 250Vac -- 200A (20-30A @ 125Vac/dc) -- 10,000A (1A -15A @ 125Vac/dc) Agency Information: CE, Std. 248-14, UL Recognized, 1-30,125Vdc/250Vac, File E56412, Guide JFHR2, CSA Accepted, 1-30, 125Vdc/250Vac, File 53787, Class 1422-30. Agency Information: CE, UL Listed, Guide JDYX, File E19180, 0-10A UL Recognized, Guide JDYX2, File E19180, 12-30A CSA Certification, Class 1422-01, File 053787, 120-30A. Features and Benefits * Original electronic glass tube fuse. * Fast-acting for maximum protection. * Wide amp/volt ratings allow versatility of protecting electronic circuits. Typical Applications * Electronic Circuits Catalog Numbers (Amps) With Axial Leads AGC-V-120-R AGC-V-116-R AGC-V-110-R AGC-V-18-R AGC-V-316-R AGC-V-210-R AGC-V-14-R AGC-V-310-R AGC-V-38-R AGC-V-12-R AGC-V-34-R AGC-V-1-R AGC-V-1- 14-R AGC-V-1- 12-R AGC-V-2-R AGC-V-2- 14-R AGC-V-2- 12-R AGC-V-3-R AGC-V-4-R AGC-V-5-R AGC-V-6-R AGC-V-7-R AGC-V-7- 12-R AGC-V-8-R AGC-V-9-R AGC-V-10-R AGC-V-12-R AGC-V-14-R AGC-V-15-R AGC-V-20-R AGC-V-25-R AGC-V-30-R Without Axial Leads AGC-120-R AGC-116-R AGC-110-R AGC-18-R AGC-316-R AGC-210-R AGC-14-R AGC-310-R AGC-38-R AGC-12-R AGC-34-R AGC-1-R AGC-1- 14-R AGC-1- 12-R AGC-2-R AGC-2- 14-R AGC-2- 12-R AGC-3-R AGC-4-R AGC-5-R AGC-6-R AGC-7-R Data Sheet: 2001 AGC-7- 12-R AGC-8-R AGC-9-R AGC-10-R AGC-12-R AGC-14-R AGC-15-R AGC-20-R AGC-25-R AGC-30-R *CSA approvals for 25A and 30A are at 125Vac - IR 1000A and Vdc - IR 400A (IR 1000A at 75Vdc) **Interrupting ratings measured at 70% - 80% power factor on AC. The interrupting ratings for 18A and 20A were measured at 85%-95% power factor on AC. The interrupting ratings for 25A and 30A were measured at 89% power factor on AC. Agency Information: CE, Std. 248-14 UL Listed, Guide JDYX File E19180, 1 4-15A; UL Recognized, Guide JDYX2, File E19180, 18-30A; CSA Certification, Class 1422-01 & 1422-30, File 53787, 1 4-30A. Features and Benefits * Ceramic body allows for higher amp/volt rating combinations. Typical Applications * Electronic Circuits Catalog Numbers (Amps) With Axial Leads ABC-V- 14-R ABC-V- 12-R ABC-V- 34-R ABC-V-1-R ABC-V-1- 12-R ABC-V-2-R ABC-V-2- 12-R ABC-V-3-R ABC-V-4-R ABC-V-5-R ABC-V-6-R ABC-V-7-R ABC-V-8-R ABC-V-10-R ABC-V-12-R ABC-V-15-R ABC-V-18-R ABC-V-20-R ABC-V-25-R ABC-V-30-R Features and Benefits * Very fast-acting performance allows protection of highly sensitive electronic circuitry. Typical Applications * Electronic Circuits Catalog Numbers (Amps) With Axial Leads GBB-V-1-R GBB-V-1-14-R GBB-V-2-R GBB-V-3-R GBB-V-4-R GBB-V-5-R GBB-V-6-R GBB-V-7-R GBB-V-8-R GBB-V-9-R GBB-V-10-R GBB-V-12-R Without Axial Leads GBB-1-R GBB-6-R GBB-1-14-R GBB-7-R GBB-2-R GBB-8-R GBB-3-R GBB-9-R GBB-4-R GBB-10-R GBB-5-R GBB-12-R GBB-V-15-R GBB-V-20-R GBB-V-25-R GBB-V-30-R GBB-15-R GBB-20-R GBB-25-R GBB-30-R Without Axial Leads ABC- 14-R ABC- 12-R ABC- 34-R ABC-1-R ABC-1- 12-R ABC-2-R ABC-2- 12-R ABC-3-R ABC-4-R ABC-5-R ABC-6-R ABC-7-R ABC-8-R ABC-10-R Data Sheet: 2000 ABC-12-R ABC-15-R ABC-18-R ABC-20-R ABC-25-R ABC-30-R Data Sheet: 2013 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 63 Electronic Fuses AGC (AGC-V axial leads) Electronic -- PCB & Small Dimension Fuses 1 4" Dia. x 1 14" Length Time-delay Ferrule Fuses MDL-V (axial leads) MDQ-V (axial leads) MDA-V (axial leads) MDL MDQ MDA Specifications Description: Time-delay fuse. Dimensions: 14 x 1 14 (6.4 x 31.7mm). Construction: Glass tube with nickel-plated brass endcaps. Ratings: Volts -- 250Vac (116-8A) -- 32Vac (9-30A) Amps -- 116-30A IR* -- 35A (116-1A @ 250Vac) -- 100A (114-3A @ 250Vac) -- 200A (4-8A @ 250Vac) -- 10000A (116-8A @ 125Vac) -- 1000A (9-30A @ 32Vac) Specifications Description: Dual-element, time-delay fuse. Dimensions: 14 x 1 14 (6.4 x 31.7mm). Construction: Glass tube with nickel-plated brass endcaps. Ratings: Volts -- 250Vac (1100-7A) -- 32Vac (712-15A) Amps -- 1100-15A IR -- 35A (1100-1A @ 250Vac) -- 100A (114-3A @ 250Vac) -- 200A (4-7A @ 250Vac) -- 1000A (712-12A @ 32Vac) Agency Information: Std. 248-14, UL Listed, File E19180; Guide JDYX, 116-7A CSA Certification, File 47233, Class 1422-01, 116 -7A, UL Recognized, Guide JDYX2, File E19180, 7.1-30A. Specifications Description: Time-delay fuse. Dimensions: 14 x 1 14 (6.35 x 31.75mm). Construction: Ceramic tube with nickel-plated brass endcaps. Ratings: Volts -- 250Vac (or less) -- 125Vdc (20A- 30A) Amps -- 14-30A IR** -- 35A (14-1A @ 250Vac) -- 100A (112-2A @ 250Vac) -- 200A (212-10A @ 250Vac) -- 750A (12-15A @ 250Vac) -- 1500A (20-30A @ 250Vac) -- 10kA (14-30A @ 125Vac) -- 10kA (20-30A @ 125Vdc) *Interrupting ratings were measured at 70% - 80% power factor on AC, and at a time constant described in UL 198L. Agency Information: CE, UL Listed, Guide JDYX, File E19180, 116-8A; CSA Certification Class 1422-01, 116-8A; UL Recognized, Guide JDYX2, File E19180, 9-30A; CSA Component Acceptance, Class 142230, 9-30A. Features and Benefits * Time-delay allows close sizing on inductive circuits. Catalog Numbers (Amps) With Axial Leads MDL-V-1-R MDL-V-1- 1 4-R MDL-V-1- 12-R MDL-V-2-R MDL-V-2- 14-R MDL-V-2- 12-R MDL-V-3-R MDL-V-4-R MDL-V-5-R MDL-V-6-R MDL-V-7-R MDL-V-8-R MDL-V-9-R MDL-V-10-R MDL-V-12-R MDL-V-15-R MDL-V-20-R MDL-V-25* MDL-V-30* Without Axial Leads MDL- 116-R MDL- 110-R MDL- 18-R MDL- 210-R MDL- 316-R MDL- 14-R MDL- 310-R MDL- 38-R MDL- 12-R MDL- 34-R MDL-1-R MDL-1- 14-R MDL-1- 12-R MDL-2-R MDL-2- 14-R MDL-2- 12-R MDL-3-R MDL-4-R MDL-5-R MDL-6-R Typical Applications * Electronic Relay and Control Circuits Catalog Numbers (Amps) Typical Applications * Electronic Circuits MDL-V- 116-R MDL-V- 110-R MDL-V- 18-R MDL-V- 210-R MDL-V- 316-R MDL-V- 14-R MDL-V- 310-R MDL-V- 38-R MDL-V- 12-R MDL-V- 34-R Features and Benefits * Dual-element design allows closer sizing to inductive circuits than any other fuses. MDL-7-R MDL-8-R MDL-9-R MDL-10-R MDL-12-R MDL-15-R MDL-20-R MDL-25* MDL-30* With Axial Leads MDQ-V-1100 MDQ-V-310 MDQ-V-132 MDQ-V-38 MDQ-V-116 MDQ-V-410 MDQ-V-110 MDQ-V-12 MDQ-V-18 MDQ-V-610 MDQ-V-15100 MDQ-V-34 MDQ-V-1751000 MDQ-V-810 MDQ-V-316 MDQ-V-1 MDQ-V-210 MDQ-V-1-210 MDQ-V-14 MDQ-V-1-14 MDQ-V-1-12 MDQ-V-1-610 MDQ-V-1-810 MDQ-V-2 MDQ-V-2-14 MDQ-V-2-12 MDQ-V-2-810 MDQ-V-3 MDQ-V-3-210 MDQ-V-4 MDQ-V-5 MDQ-V-6 MDQ-V-6-14 MDQ-V-7 MDQ-V-7-12 MDQ-V-8 MDQ-V-9 MDQ-V-10 MDQ-V-12 MDQ-15 Without Axial MDQ-1100 MDQ-132 MDQ-116 MDQ-110 MDQ-18 MDQ-15100 MDQ-1751000 MDQ-316 MDQ-210 MDQ-14 MDQ-1-12 MDQ-1-610 MDQ-1-810 MDQ-2 MDQ-2-14 MDQ-2-12 MDQ-2-810 MDQ-3 MDQ-3-210 MDQ-4 MDQ-5 MDQ-6 MDQ-6-14 MDQ-7 MDQ-7-12 MDQ-8 MDQ-9 MDQ-10 MDQ-12 MDQ-15 Leads MDQ-310 MDQ-38 MDQ-410 MDQ-12 MDQ-610 MDQ-34 MDQ-810 MDQ-1 MDQ-1-210 MDQ-1-14 *MDL-25 & MDL-30 are not available in RoHS compliant construction. Data Sheet:2004 64 Data Sheet: 2044 **Interrupting ratings were measured at 70% - 80% power factor on AC, and at a time constant described in UL 248. Agency Information: CE, Std. 248-14, UL Listed, Guide JDYX, File E19180, 0-20A CSA Certification, Class 1422-01, File 53787, 0-20A. UL Recognized, Guide JDYX2, File E19180, 25-30A, CSA Component Acceptance, Class 1422-30, 25-30A Features and Benefits * Ceramic body allows for higher amp/volt rating combinations. * Inventory consolidation by replacing MDL fuses allows for reduced SKU investment and minimizing potential for misapplying fuse. Typical Applications * Electronic Circuits Catalog Numbers (Amps) With Axial Leads MDA-V-14-R MDA-V-12-R MDA-V-34-R MDA-V-1-R MDA-V-1-12-R MDA-V-2-R MDA-V-2-12-R MDA-V-3-R MDA-V-4-R MDA-V-5-R MDA-V-6-R MDA-V-7-R MDA-V-8-R MDA-V-10-R MDA-V-12-R MDA-V-15-R MDA-V-20-R MDA-V-25-R MDA-V-30-R Without Axial Leads MDA-14-R MDA-12-R MDA-3-R MDA-4-R MDA-12-R MDA-15-R MDA-34-R MDA-1-R MDA-1-1 2-R MDA-2-R MDA-2-12-R MDA-5-R MDA-6-R MDA-7-R MDA-8-R MDA-10-R MDA-20-R MDA-25A-R MDA-30A-R Data Sheet: 2002 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Electronic -- PCB & Small Dimension Fuses PC Board Mount Fuse Holders HTC-45M HTC-60M, HTC-65M PCB Horizontal Mount PCB Stand-Off Mount Electronic Fuses HTC-50M PCB Vertical Mount Specifications Description: PCB vertical mount bayonet cap and fuse holder. Dimensions: See Dimensions illustration. Ratings: See Specifications table. Dimensions - in (mm) 1.303" Mounting Holes (33.1mm) Specifications Description: PCB horizontal mount bayonet cap and fuse holder. Dimensions: See Dimensions illustration. Ratings: See Specifications table. Dimensions - in (mm) 1.303" (33.1mm) Printed Circuit Board Mounting Holes _ 0.002" Dia. (Typ.) 0.051" + ( 1.30 _+ 0.05mm) 0.394" Dimensions - in (mm) HTC-65M (4-Leg) 0.197" 0.591" (5.0mm) (10.0mm) (15.0mm) 0.394" _ 0.002" Dia. (Typ.) 0.051" + ( 1.30 _+ 0.05mm) Specifications Description: Four-leg PCB stand-off fuse holder. Dimensions: See Dimensions illustration. Ratings: Volts: -- 250V Amps: -- 6.3A Printed Circuit Board (10.0mm) 0.102" Dia. Hole (2.6mm) 0.051" Dia. Hole (1.3mm) 0.512" (13.0mm) 0.512" (13.0mm) S FU E 0.886" 0.354" (22.5mm) (9.0mm) 0.551" S FU E (14.0mm) 0.461" (11.7mm) 0.461" (11.7mm) Data Sheet 2110 Data Sheet 2110 0.138" (3.5mm) Data Sheet 2110 Specifications Volts: 250V Amps: UR: 10A, VDE: 6.3A Terminals: For HTC-45M, HTC-50M Tin-plated. Molded Materials: High temperature thermoplastic that meets the flammability ratings of UL 94V0; Glow Wire Test: 960C per IEC 695-2-1. Solderability: In accordance with IEC 68-2-20. Electrical: Contact Resistance: ) 10m1; Insulation Resistance: * 10 megohm; Dielectric Strength * 2000 Vac. Shock Safety: PC2 (fuse holders). Agency Information: CE, HTC-45M, HTC-50M UL Recognized, (Guide IZLT8, File E14853; VDE HTC-45M & HTC-50M File: 40004456; HTC-65M File: 40004455. Packaging: Standard Qty 10 (No Prefix), Bulk Qty 100 (Prefix Catalog Number with BK/). For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 65 Electronic -- PCB & Small Dimension Fuses PC Board Mount Fuse Holders HBH-I HBV-I (for 14" x 1 14" fuses) HBH-M HBV-M (for 5 x 20mm fuses) HBW-I (for 14" x 1 14" fuses) (for 14" x 1 14" fuses) HBW-M (for 5 x 20mm fuses) (for 5 x 20mm fuses) PCB Horizontal PCB Vertical Mount PCB Vertical Mount Mount with Stability Pins without Stability Specifications Description: PCB horizontal mount fuse holder. Dimensions: See Dimensions illustration. Ratings: See Specifications table. Specifications Description: PCB vertical mount fuse holder with stability pins. Dimensions: See Dimensions illustration. Ratings: See Specifications table. Pins Dimensions - in (mm) Dimensions - in (mm) Dimensions - in (mm) Specifications Description: PCB vertical mount fuse holder without stability pins. Dimensions: See Dimensions illustration. Ratings: See Specifications table. 0.531" (13.5mm) 0.200" (5.0mm) (13.0mm) 0.100" Dia. 4 Holes 0.200" (2.54mm) (5.0mm) 0.510" Dia. 2 Holes (1.3mm) 0.531" HBV (13.5mm) 1.855" 0.400" 1.855" (47.0mm) 0.050" Dia. 2 Holes 0.050" (13.0mm) (47.0mm) HBW 0.510" Panel 0.400" (10.0mm) PC Board (10.0mm) (1.3mm) Panel PC Board 0.040" (1.05mm) 0.040" (1.05mm) 0.580" (14.9mm) 0.580" (14.9mm) Data Sheet: 2118 Data Sheet: 2118 FBI Data Sheet: 2118 FBM Fuse Holder Caps (Fit all three shown above) Specifications Electrical Ratings: UL -- 16A @ 250V; CSA -- 12A @ 250V; VDE -- 6.3A @ 250V; SEMKO -- 10A @ 250V Insulation resistance -- 10 megohm at 500Vdc. Contact resistance -- less than 0.005 ohms @ 200mV. Dielectric strength -- over 200V/mil. Molded Material: High dielectric molded phenolic with a UL 94V0 flammability rating. Fuse Carrier & Knob: Spring-loaded, bayonet-type. Tin plated brass. Screwdriver slotted. Mounting: "Kicked" terminals (all models) and stabilizer pins on HBV & HBW models for increased stability. Temperature Rating (RTI): Body: 150C, Knob: 130C Agency Information: CE, UL Recognized -- Guide IZLT2, File EI4853; CSA Certified -- Class 6225-01, File 47235 VDE -- 4009241 (HBV, HBW) SEMKO -- 800444 66 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Electronic -- PCB & Small Dimension Fuses PC Board Fuseclips for 5mm Diameter Fuses HTC-15M, HTC-140M PCB Mounted Fuse Holder & Snap-On Cover 0.217 " 1.047" (26.6mm) HTC-140M Cover 0.571" 0.890" (22.60mm) 0.866" (22.0mm) 0 217 " 0.177" 0.319" 0.50" (8.1mm) (12.7mm) BUSS (4.5mm) (4.5mm) + .05mm) (1.50 _ BUSS HTC-200M 0.177" _ 0.002" Dia. (Typ.) 0.059" + PCB Mounted Fuseclip 0.157" (3.99mm) 0.929" Construction: Tin-plated bronze Tape and Fan Fold packed Ammo Pack (AP/HTC-200M) 1000 pieces per box Electronic Fuses Data Sheet: 2110 Mounting Holes (13.5mm) (9.0mm) (14.5mm) (5.5mm) 0.531" 0.345" BUSS Voltage Rating: 250V, 6.3A, 1.6W HTC-15M (fuse holder), HTC-140M (natural cover), HTC-150M* (transparent cover) *Available in bulk only. Use this format: BK/HTC-150M (23.6mm) 0.61" (15.5mm) 0.031" 0.012" 0.217" (0.79mm) (0.3mm) (5.5mm) 0.50" 0.50" (12.7mm) (12.7mm) Data Sheet: 2110 HTC-210M 4.32mm PCB Mounted Fuseclip with End Stops Data Sheet: 2110 2.54mm 8.73mm 6.26mm 2.54mm 1.46mm 2.54mm 3.91mm 6.22mm 2.85mm 1A3399 Series PCB Fuseclips with End Stops & Straight Leads Catalog Numbers Clip Material* Finish 1A3399-01 Beryllium copper* Silver 1A3399-04-R Beryllium copper* Bright tin 1A3399-10-R Spring bronze Bright tin 2.29mm 0.062" 0.115" 0.125" (1.6mm) (2.9mm) 0.254" (3.2mm) 0.237" (6.5mm) (6.0mm) 0.225" (5.7mm) 0.030" (1.6mm) 0.060" 0.125" (1.5mm) (3.2mm) 0.188" (4.8mm) *Beryllium copper recommended for amps higher than 15 amps. Data Sheet: 2131 1A5018 Series PCB High Profile Catalog Numbers 1A5018-7 1A5018-10-R 0.180" (4.57mm) Fuseclips with End Stops & Straight Leads Clip Material* Finish Spring bronze Silver Spring bronze Bright tin 0.440" (11.2mm) 0.230" (5.84mm) 0.047" (1.2mm) 0.140" 0.180" (3.7mm) (4.6mm) *Beryllium copper recommended for amps higher than 15 amps. Data Sheet: 2131 1A5601 Series 0.246" 0.344" + 0.015" (6.3mm) (8.73mm + 0.38mm) PCB Fuseclips (0-7A) Catalog Number Clip Material 1A5601 Cartridge brass 0.344" + 0.015" Finish Bright tin Data Sheet: 2131 (8.73mm + 0.38mm) 0.141" + 0.015" (3.58mm + 0.38mm) 0.060" 0.266" (1.5mm) (6.75mm) 0.022" + 0.002" 0.032" + 0.002" (0.56mm + 0.05mm) 1A5602 Series (0.81mm + 0.05mm) 0.219" (5.57mm) PCB Fuseclips (0-7A) Catalog Number Clip Material 1A5602 Cartridge brass Data Sheet: 2131 0.250" (6.35mm) Finish Bright tin 0.500" 0.250" (12.70mm) (6.35mm) 0.140" (3.56mm) 0.093" (2.36mm) 0.047" 0.216" (5.48mm) LEGS TO FIT IN 0.052" (1.3mm) DIA. HOLES ON CENTER For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa (1.19mm) 67 Electronic -- PCB & Small Dimension Fuses PC Board Fuseclips for 14" Diameter Fuses 1A3398 Series (2.6mm) (7.1mm) 0.250" PCB Fuseclips without End Stops with Straight Leads Catalog Numbers Clip Material Finish 1A3398-07-R Cartridge brass Bright tin (6.35mm) (3.94mm) 0.410" (10.4mm) 0.060" Data Sheet: 2131 0.155" 0.245" (6.2mm) (1.5mm) 0.320" 0.140" 0.102" Dia. 0.280" (2.6mm) (7.1mm) 0.280" (3.6mm) (7.1mm) (8.13mm) 1A1907 Series PCB Fuseclips with End Stops & Straight Leads Catalog Numbers Clip Material* Finish 1A1907-02 Cartridge brass None/bright dipped 1A1907-03-R Beryllium copper* Bright tin 1A1907-05 Beryllium copper* Silver 1A1907-06-R Cartridge brass Bright tin 0.102" Dia. 0.280" (2.6mm) (7.1mm) 0.255" (6.5mm) 0.060" 0.320" Data Sheet: 2131 (6.2mm) 0.410" (10.4mm) (1.5mm) *Beryllium copper recommended for amps higher than 15A. 0.155" (3.94mm) 0.245" 0.140" 0.102" Dia. 0.280" (2.6mm) (7.1mm) 0.280" (3.6mm) (7.1mm) (8.13mm) 1A4533 Series 0.245" (6.2mm) PCB Fuseclips without End Stops or Angled Out Leads Catalog Numbers Clip Material* Finish 1A4533-01-R Beryllium copper* Bright tin 1A4533-06-R Cartridge brass Bright tin 0.410" 0.255" (6.5mm) 0.060" Data Sheet: 2131 (1.5mm) 0.320" 0.280" (8.13mm) (7.11mm) 0.228" 0.150" (5.79mm) (3.81mm) 0.323" (8.20mm) 1A4534 Series 0.245" (6.2mm) 0.155" (3.94mm) 0.410" 0.255" (6.5mm) 0.060" Data Sheet: 2131 (1.5mm) 0.320" 0.280" (8.13mm) (7.11mm) 0.228" 0.150" (5.79mm) (3.81mm) 0.323" (8.20mm) 1A1119 Series In Leads Finish Bright tin Silver Bright tin *Beryllium copper recommended for amps higher than 15A. 0.102" (2.6mm) (10.4mm) *Beryllium copper recommended for amps higher than 15A. Fuseclips with End Stops & Angled Catalog Numbers Clip Material* 1A1119-04-R Beryllium copper* 1A1119-05 Beryllium copper* 1A1119-10-R Cartridge brass 0.102" (2.6mm) (10.4mm) *Beryllium copper recommended for amps higher than 15A. PCB Fuseclips with End Stops & Angled Out Leads Catalog Numbers Clip Material* Finish 1A4534-01-R Beryllium copper* Bright tin 1A4534-06-R Cartridge brass Bright tin 0.155" (3.94mm) 0.132" 0.285" (3.4mm) (7.24mm) 0.420" 0.187" (10.67mm) (4.8mm) 0.312" (7.9mm) 0.250" 0.290" (6.5mm) 0.155" 0.080" (3.9mm) (7.4mm) 0.360" (2.03mm) (9.14mm) Data Sheet: 2131 1A1120 Series PCB Fuseclips without End Stops or Angled In Leads Catalog Numbers Clip Material* Finish 1A1120-02 Cartridge brass None/bright dipped 1A1120-05 Beryllium copper* Silver 1A1120-06-R Beryllium copper* Bright tin 1A1120-09-R Cartridge brass Bright tin *Beryllium copper recommended for amps higher than 15A. Data Sheet: 2131 68 ( ) 0.132" 0.265" (3.4mm) (6.7mm) 0.410" 0.187" (10.4mm) (4.8mm) 0.290" 0.155" 0.080" (3.9mm) (2.03mm) 0.312" (7.9mm) 0.255" (6.5mm) (7.4mm) 0.360" (9.14mm) For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Electronic -- PCB & Small Dimension Fuses PC Board Fuseclips for 1332" Diameter, ATM and ATC(R) fuses 1A3400 Series 0.050" 0.437" PCB Fuseclips for 1332" diameter fuses with End Stops & Straight Leads Catalog Amp Clip Number Rating Material Finish 1A3400-09 20A Max. Spring bronze Bright tin Data Sheet 2131 (1.27mm) (11.1mm) 0.218" (5.5mm) 0.142" Dia. (3.6mm) 0.470" (11.9mm) 0.710" 0.080" Electronic Fuses (18.0mm) 0.380" (2.0mm) (9.7mm) 0.470" (11.9mm) 1A5600 Series 0.295" (7.49mm) PCB Fuseclips for ATC Fuses (0-20A) Catalog Number Clip Material Finish 1A5600 Brass Satin finish tin 0.330" (8.38mm) Data Sheet 2131 0.053" (1.35mm) 0.090" 0.200" 0.150" (2.29mm) (5.08mm) (3.81mm) 0.090" (2.29mm) 0.180" (4.57mm) 1A5778 1A5779 Series 1A5780 Series PCB Fuseclips for ATM Fuses PCB Fuseclips for ATM Fuses PCB Fuseclips for ATC Fuses 14.68 0.578 19.30 0.760 1.24 0.049 1.90 0.075 4.75 0.187 3.96 0.156 4.45 0.175 3.18 0.125 BASE BASE 6.88 0.271 4.98 0.196 FUSECLIPS FUSECLIPS 11.18 0.440 6.35 0.250 1.57 0.062 3.18 0.125 11.10 0.437 8.64 0.340 1.27 0.050 3.18 0.125 2.54 0.100 1.57 0.062 3.66 0.144 3.66 0.144 2.18 0.086 4.47 0.176 5.08 0.200 1.45 .057 3.66 0.144 4.06 0.160 5.08 0.200 1.57 0.062 2.54A}0.05 DIA. HOLE 0.100A}0.002 (TYP-4) 3.66 0.144 MOUNTING LAYOUT 1.65A}0.05 DIA. HOLE 0.065A}0.002 (TYP-4) 3.66 0.144 4.47 0.176 3.66 0.144 MOUNTING LAYOUT FOR 2 CLIPS MATERIAL: BRASS, NICKEL PLATED, 0.30 THICK 0.012 1.65A}0.05 DIA. HOLE 0.065A}0.002 (TYP-4) MOUNTING LAYOUT Data Sheet 2131 Data Sheet 2131 SPECIFICATIONS FUSECLIPS . . . . . . . . BRASS, NICKEL PLATED BASE MATERIAL GLASS FILLED NYLON, UL RATED 94V0 ..... CURRENT RATING . . . . . 15 AMPS VOLTAGE RATING . . . . . 500Vac SPECIFICATIONS TEMPERATURE RATING . . -50C, -58F TO 145C, 292F FUSECLIPS . . . . . . . . BRASS, NICKEL PLATED BASE MATERIAL GLASS FILLED NYLON, UL RATED 94V0 ..... CURRENT RATING . . . . . 15 AMPS VOLTAGE RATING . . . . . 500Vac TEMPERATURE RATING . . -50C, -58F TO 145C, 292F Data Sheet 2131 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 69 Electronic -- PCB & Small Dimension Fuses PC Board Fuseclips for 14, 932, 1332 and 916 Diameter Fuses 5681 & 5682 Series PCB Fuseclips with Mounting Holes For 14 Diameter Fuses Catalog Number End Stop Clip Mat.** Finish BeCu Silver Spg. Br. Nickel 5681-15-R Spg. Br. Bright Tin 5682-01 BeCu Silver 5682-02 BeCu Silver 5681-01 5681-08 5682-11-R No Yes B (To C Dimensions (Inches) D E End Stop) (Contact) (Height) (Width) Hole Dia. Ref. 0.265 0.41 0.32 0.132 Fig. 2 0.262 0.41 0.32 0.132 Fig. 1 B C 0.108 BeCu Bright Tin 0.131 5682-41-R Spg. Br. Bright Tin 0.106 5682-44-R Spg. Br. Bright Tin 0.132 D 5672 & 5674 Series PCB Fuseclips with Mounting Holes For 932 Diameter Fuses E End Stop Clip Mat.** Finish End Stop) (Contact) (Height) (Width) Hole Dia. Ref. 5672-11 No Spg. Br. Bright Tin 0.362 0.52 0.38 0.172 Fig. 2 BeCu Silver 0.168 0.356 0.52 0.38 0.172 Fig. 1 5674-01 5674-10 Yes 5674-41 B (To Dimensions (Inches) D E Catalog Number BeCu Bright Tin Spg. Br. Bright Tin C Figure 1 5956 & 5960 Series PCB Fuseclips with Mounting Holes For 1332 Diameter Fuses End Stop Clip Mat.** Finish End Stop) (Contact) (Height) (Width) Hole Dia. 5956-16 No Spg. Br. Bright Tin 0.47 0.172 Fig. 2 5960-07 BeCu Silver 0.168 5960-09 BeCu Silver 0.20 0.172 5960-44 Spg. Br. Nickel 0.20 0.197 Spg. Br. Bright Dip* 0.168 5960-53 Spg. Br. Bright Dip* 0.20 0.172 5960-61-R Spg. Br. Bright Tin 0.168 0.196 5960-62-R Spg. Br. Bright Tin 0.168 0.132 5960-63-R Spg. Br. Bright Tin 0.20 0.172 5960-64-R Spr. Br. Bright Tin 0.20 0.128 5960-51 Yes B (To Dimensions (Inches) D E Catalog Number C 0.312 0.71 Ref. 0.196 0.387 0.71 0.47 C 0.196 Fig. 1 D 5591 & 5592 Series PCB Fuseclips with Mounting Holes For 916" Diameter Fuses Catalog Number 5591-42 5591-52-R 5592-01 5592-11 End Stop Yes No Dimensions (Inches) B (To C D E Hole End Stop) (Contact) (Height) (Width) Dia. Clip Mat.** Finish Spg. Br. Bright Dip* Spg. Br. Bright Tin BeCu Silver Spg. Br. Silver Ref. 0.26 0.51 0.89 0.60 0.172 Fig. 1 0.252 0.56 0.875 0.60 0.20 0.20 E Figure 2 Fig. 2 * Bright Dip is actually treated bare metal with no plating. ** Spg. Br. -- Spring Bronze; BeCu -- Beryllium Copper. Hole in center of both clip and contact area. Data Sheet: 2132 70 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Medium Voltage Fuses Section Contents Page Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 E-Rated Fues For transformers & feeders . . . . . . . . . . . . . . . . . . . . . . .75 CL-14 & bolt-in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 CL-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 For potential & small power transformers . . . . . . . . . . 78-79 British IEC fuses for motor circuit protection . . . 83 DIN IEC fuses for transformer protection . . . . . . 84 Potential transformer fuses . . . . . . . . . . . . . . . . . 85 British IEC fuses for oil-filled switchgear . . . . . . 86 Fast-acting fuses . . . . . . . . . . . . . . . . . . . . . . . . . 87 EEI-NEMA Type K & T and Type H & N fuses . . . 88 BBU Boric acid fuses . . . . . . . . . . . . . . . . . . . 89-90 Fuseclips for medium and high voltage fuses . . . 91 71 Medium Voltage Fuses R-Rated fuses for motor circuit protection . . . 80-82 Medium Voltage Fuses Medium Voltage Fuses Worldwide Circuit Protection Solutions Cooper Bussmann is a world-leading supplier of medium voltage fuses. Each product is backed by an efficient worldwide distribution network with unrivaled service and technical support. Cooper Bussmann circuit protection solutions comply with major international standards: ANSI, BS, DIN, IEC and UL. Fuse Types Medium voltage fuses generally fit into two categories - expulsion fuses and current limiting fuses. The definitions per ANSI C37.40 are: Expulsion Fuse: "A vented fuse in which the expulsion effect of the gases produced by internal arcing, either alone or aided by other mechanisms results in current interruption." Expulsion fuses will limit the duration of an overcurrent event, but they will not limit the magnitude of fault current. Cooper Bussmann offers two types of expulsion fuses: replacement fuse links for fused cutouts and boric acid fuses. Current Limiting Fuse: "A fuse unit that, when in its currentresponsive element is melted by a current within the fuse's specified current-limiting range, abruptly introduces a high resistance to reduce current magnitude and duration, resulting in subsequent current interruption." A current limiting fuse will reduce the magnitude a fault current as well as limit the duration of the overcurrent event when operating in its current limiting range. Cooper Bussmann offers a broad range of current limiting fuses for protection of feeders, transformers and motor circuits designed to ANSI, BS, DIN and IEC standards. Medium Voltage Current Limiting Fuses Current limiting fuses are classified into three categories: 1. Full Range - defined by ANSI C37.40 as "a fuse capable of interrupting all currents from the maximum rated interrupting current down to the minimum continuous current that causes the melting of the fusible element(s), when the fuse is applied at the maximum ambient temperature specified by the manufacturer." It is able to interrupt any current that will melt its element. 72 2. General Purpose - defined by ANSI C37.40 as "a fuse capable of interrupting all currents from the maximum rated interrupting current down to the current that causes melting of the fusible element(s) in one hour." Not all currents fall within this range. It is possible for the fuse to be exposed to an overcurrent lower than the value given by the one hour criteria. In that case, a different overcurrent protection device would be required to interrupt the overcurrent. 3. Back-up - defined by ANSI C37.40 as "a fuse capable of interrupting all currents from the maximum interrupting rating current down to the minimum interrupting current." The minimum interrupting current is the lowest current that the fuse will be able to clear properly. This creates a need to place a low current interrupting device, such as motor overloads, in series with the back-up rated fuse. E- and R-Rated Fuses In North America, current limiting fuses typically fall into the category of E-Rated fuses and R-Rated fuses. Cooper Bussmann also offers a wide range of current limiting fuses designed to BS, DIN and IEC standards. E-Rated fuses are used to protect feeder circuits, power transformers and potential transformers. E-Rated fuses have defined current response times specified by ANSI C37.46. E-Rated fuses 100A and below must melt in 300sec at an rms current within the range of 200% to 240% of the continuous current rating. E-Rated fuses above 100A must melt in 600sec at an rms current within the range of 240% to 264% of the continuous current rating of the fuse. Cooper Bussmann offers a wide variety of full range and general purpose E-Rated fuses from 2.4kV up to 38kV. R-Rated fuses are back-up fuses that provide short-circuit protection for motor circuits. They are applied with MV motor starters which provide the overload protection for the circuit. R-Rated fuses also have defined current response times specified by ANSI C37.46. R-Rated fuses will melt in a range of 15 - 35sec at a current equal to 100 times the "R" rating. Cooper Bussmann offers 2.4kV, 5.08kV, 7.2kV and 8.3kV R-Rated fuses for motor circuit protection. For detailed information, visit the Electrical IEC section at www.cooperbussmann.com Medium Voltage Fuses E-rated Fuses for Transformers and Feeders 5.5kV Catalog Numbers MV055 and MV155 Catalog Numbers MV055 Features and Benefits * Standard clip center distance of 12 inches with 2 and 3 inch barrel diameters for retrofitting in existing hardware * Open fuse indicator for ease in troubleshooting * Full range rating with 50,000 Interrupting Rating * Double pulsed at 90% of minimum I2t to establish manufacturing reliability * * * * MV055 Typical Applications 5.0kV Transformer Primary Protection 5.0kV Feeder Circuit Protection 5.0kV Voltage Switches 5.0kV Metal-enclosed Switchgear MV155 Features and Benefits * Standard clip center distance of 15 and 18 inches with 2 and 3 inch barrel diameters for retrofitting in existing hardware * Open fuse indicator for ease in troubleshooting * Full range rating with 50,000 Interrupting Rating * Double pulsed at 90% of minimum I2t to establish manufacturing reliability * * * * MV155 Typical Applications 15.0kV Transformer Primary Protection 15.0kV Feeder Circuit Protection 15.0kV Voltage Switches 15.0kV Metal-enclosed Switchgear Min Melt I2t MV055F1CAX5E 5 180 MV055F1CAX7E 7 850 MV055F1CAX10E 10 850 MV055F1CAX15E 15 2,070 MV055F1CAX20E 20 2,370 MV055F1CAX25E 25 4,650 MV055F1CAX30E 30 9,490 MV055F1CAX40E 40 9,490 MV055F1CAX50E 50 13,600 MV055F1CAX65E 65 30,700 MV055F1DAX10E 10 850 MV055F1DAX15E 15 2,070 MV055F1DAX20E 20 2,370 MV055F1DAX25E 25 4,650 MV055F1DAX30E 30 9,490 MV055F1DAX40E 40 9,490 MV055F1DAX50E 50 13,600 MV055F1DAX65E 65 30,700 MV055F1DAX80E 80 54,600 MV055F1DAX100E 100 116,200 MV055F1DAX125E 125 167,400 MV055F1DAX150E 150 218,700 MV055F1DAX175E 175 227,900 MV055F1DAX200E 200 297,600 MV055F2DAX250E 250 669,600 MV055F2DAX300E 300 874,800 MV055F2DAX350E 350 911,600 MV055F2DAX400E 400 1,190,400 MV055F2DAX450E 450 1,555,000 1" = 25.4mm Recommended Fuse Clips - see page 91 Max Clear I2t 2,400 8,000 8,000 11,000 23,000 31,000 45,000 45,000 90,000 181,000 8,000 12,000 23,000 31,000 45,000 45,000 90,000 181,000 270,000 580,000 600,000 786,000 1,100,000 1,520,000 2,400,000 3,149,000 4,376,000 6,071,000 9,796,000 Dimensions (in)* Clip Length Dia. Center Barrels 15.75 2 12 1 12 1 2 15.75 3 Medium Voltage Fuses Specifications Description: E-rated medium, voltage currentlimiting fuses: for transformer and feeder protection. Dimensions: See Catalog Numbers table. Construction: Silver ribbon element surrounded by silica filler housed in a fiberglass tube and plated endcaps. An epoxy paint protects the fuse tube from the surrounding environment. Ratings: Volts: -- 5.5kV (5-450A) -- 15.5kV (5-200A) Amps: -- 5-450A (5.5kV) -- 5-200A (15.5kV) IR: -- 50kA Sym. Max Agency Information: Meets E requirements per ANSI C37.46, Meets full range requirements per ANSI C37.40. Amp Rating 1 12 15.75 3 15.75 3 12 1 15.75 3 12 2 2 Data Sheet: 6700 15.5kV Catalog Numbers Catalog Numbers MV155F1CBX5E MV155F1CBX7E MV155F1CBX10E MV155F1CBX15E MV155F1CBX20E MV155F1CBX25E MV155F1CBX30E MV155F1DBX10E MV155F1DBX15E MV155F1DBX20E MV155F1DBX25E MV155F1DBX30E MV155F1DBX40E MV155F1DBX50E MV155F1DBX65E MV155F1DBX80E MV155F1DBX100E MV155F2DBX125E MV155F2DBX150E MV155F2DBX175E MV155F2DBX200E MV155F1DCX65E MV155F1DCX80E MV155F1DCX100E MV155F2DCX125E MV155F2DCX150E MV155F2DCX175E MV155F2DCX200E *1" = 25.4mm. Amp Rating Min Melt I2t Max Clear I2t 5 7 10 15 20 180 850 850 2,070 2,370 2,900 8,000 8,000 12,000 23,000 25 30 10 15 20 25 30 40 50 65 80 100 125 150 175 200 65 80 100 125 150 175 200 4,650 9,490 850 2,070 2,370 4,650 9,490 9,490 13,600 30,700 54,600 116,200 123,000 218,700 314,700 465,100 30,700 54,600 116,200 123,000 218,700 314,700 465,100 31,000 45,000 8,000 12,000 23,000 31,000 45,000 45,000 90,000 181,000 270,000 600,000 677,000 1,287,000 1,689,000 2,405,000 181,000 270,000 600,000 677,000 1,287,000 1,689,000 2,405,000 Dimensions* Clip Center Barrels Length Dia. 18.75 15 1 15 1 1 2 18.75 3 15 18.75 18.75 3 3 15 2 2 21.75 3 18 1 1 21.75 21.75 3 18 18 2 2 Recommended Fuse Clips - see page 91 Data Sheet: 6701 (MV155) For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 73 Medium Voltage Fuses E-rated Fuses for Transformer & Feeders JCX, JCY, JCU, JCZ and JDZ Specifications Description: Indoor/enclosure E-rated medium voltage, currentlimiting fuses for feeders and power transformers with blown fuse indication. Dimensions: See Catalog Numbers table. Construction: plated ferrules. Ratings: Volts: -- 2750-8300V (See Catalog Numbers table for details) Amps: -- 12-750A IR: -- 40-63kA Sym -- 60-100kA ASYM -- See Catalog Numbers table for details Catalog Numbers Catalog Amp Maximum Numbers Rating Design Voltage 2400V; E-Rated; Indoor/Enclosure JCX-12E 0.5 2750 JCX-1E 1 2750 JCX-2E 2 2750 JCX-3E 3 2750 JCX-5E 5 2750 JCX-7E 7 2750 JCX-10E 10 2750 JCX-15E 15 2750 JCX-20E 20 2750 JCX-25E 25 2750 JCX-30E 30 2750 JCX-40E 40 2750 JCX-50E 50 2750 JCX-65E 65 2750 JCX-80E 80 2750 JCX-100E 100 2750 JCX-125E 125 2750 JCX-150E 150 2750 JCX-200E 200 2750 JCX-225E 225 2750 JCX-250E/280X 250/280 2750 JCX-300E/325X 300/325 2750 JCX-350X 350 2750 JCX-400X 400 2750 JCX-450X 450 2750 5500V; E-Rated; Indoor/Enclosure JCY-12E 0.5 5500 JCY-1E 1 5500 JCY-2E 2 5500 JCY-3E 3 5500 JCY-5E 5 5500 JCY-7E 7 5500 JCY-10E 10 5500 JCY-15E 15 5500 JCY-20E 20 5500 JCY-25E 25 5500 Constrruction Features and Benefits * Physically dimensioned for retrofitting in existing hardware * Open fuse indicator for ease in troubleshooting * Full range ANSI classification * * * * Typical Medium Medium Medium Medium Maximum Interrupting Capacity Amps (Asym.) Amps (Sym.) Applications Voltage Transformer Primary Protection Voltage Feeder Circuit Protection Voltage Switches Voltage Metal-enclosed Switchgear Dimensions - in (mm) Length Diameter Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Double Double Double Double Double 60,000 60,000 60,000 60,000 60,000 60,000 60,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 40,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 9.19 (233.38) 9.19 (233.38) 9.19 (233.38) 9.19 (233.38) 9.19 (233.38) 9.19 (233.38) 9.19 (233.38) 9.5 (241.3) 9.5 (241.3) 9.5 (241.3) 10.81 (276.35) 10.81 (276.35) 10.81 (276.35) 10.81 (276.35) 10.81 (276.35) 10.81 (276.35) 10.81 (276.35) 10.81 (276.35) 10.81 (276.35) 10.81 (276.35) 10.81 (276.35) 10.81 (276.35) 10.81 (276.35) 10.81 (276.35) 10.81 (276.35) 2 (50.8) 2 (50.8) 2 (50.8) 2 (50.8) 2 (50.8) 2 (50.8) 2 (50.8) 2.1 (53.34) 2.1 (53.34) 2.1 (53.34) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) Single Single Single Single Single Single Single Single Single Single 60,000 60,000 60,000 60,000 60,000 60,000 60,000 60,000 60,000 60,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 11.19 11.19 11.19 11.19 11.19 11.19 11.19 11.19 11.19 11.19 2 2 2 2 2 2 2 2 2 2 (284.18) (284.18) (284.18) (284.18) (284.18) (284.18) (284.18) (284.18) (284.18) (284.18) Contact Cooper Bussmann for the latest product information on E-Rated fuses for transformer and feeder protection. Recommended fuseclips: see page 91 - 1A0065, 9078A67G04, A3354730 74 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa (50.8) (50.8) (50.8) (50.8) (50.8) (50.8) (50.8) (50.8) (50.8) (50.8) Medium Voltage Fuses E-rated Fuses for Transformer & Feeders Catalog Numbers: E-Rated; Indoor/Enclosure Maximum Design Voltage Constrruction Maximum Interrupting Capacity Amps. (Asym.) Amps. (Sym.) Dimensions - in (mm) Length Diameter 5500 5500 5500 5500 5500 5500 5500 5500 5500 5500 5500 5500 5500 5500 5500 5500 5500 5500 5500 5500 5500 Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Double Double Double Double * * 80,000 80,000 80,000 80,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 80,000 80,000 50,000 50,000 50,000 50,000 63,000 63,000 63,000 63,000 63,000 63,000 63,000 63,000 63,000 63,000 63,000 63,000 63,000 63,000 63,000 50,000 50,000 17.81 12.88 12.88 12.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 28.81 28.81 (452.4) (327.0) (327.0) (327.0) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (731.77) (731.77) 3 (76.2) 2.1 (53.34) 2.1 (53.34) 2.1 (53.34) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 4 (101.60) 4 (101.60) 8300 8300 8300 8300 8300 8300 8300 8300 8300 8300 8300 8300 8300 8300 8300 8300 8300 8300 8300 8300 8300 Single Single Single Single Single Single Single Single Single Single Single Double Single Single Single Single Single Single Double Double Double 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 15.51 15.51 15.51 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 15.88 15.88 15.88 15.88 15.88 15.88 15.88 15.88 15.88 (393.95) (393.95) (393.95) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (454.15) (403.2) (403.2) (403.2) (403.2) (403.2) (403.2) (403.2) (403.2) (403.2) 2.1 (53.34) 2.1 (53.34) 2.1 (53.34) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) Medium Voltage Fuses Catalog Amp Numbers Rating 5500V; E-Rated; Indoor/Enclosure JCU-10E 10 JCU-15E 15 JCU-20E 20 JCU-25E 25 JCU-30E 30 JCU-40E 40 JCU-50E 50 JCU-65E 60 JCU-80E 80 JCU-100E 100 JCU-125E 125 JCU-150E 150 JCU-175E 175 JCU-200E 200 JCU-250E 250 JCU-300E 300 JCU-350E 350 JCU-400E 400 JCU-450E 450 JCU-600E 600 JCU-750E 750 8300V; E-Rated; Indoor/Enclosure JCZ-15E 15 JCZ-20E 20 JCZ-25E 25 JCZ-30E 30 JCZ-40E 40 JCZ-50E 50 JCZ-65E 65 JCZ-80E 80 JCZ-100E 100 JCZ-125E 125 JCZ-150E 150 JCZ-200E 200 JDZ-20E 20 JDZ-25E 25 JDZ-30E 30 JDZ-40E 40 JDZ-50E 50 JDZ-65E 65 JDZ-80E 80 JDZ-100E 100 JDZ-125E 125 Recommended fuseclips: see page 91 - 1A0065, 9078A67G04, A3354730 General Notes: 1. All fuses are fitted with a striker pin which can be used for indication or tripping purposes. 2. The fuses are suitable for use either indoors or outdoors. 3. These fuses are interchangeable with corresponding fuses produced by most other leading North American manufacturers. Contact Cooper Bussmann for the latest product information on E-Rated fuses for transformer and feeder protection. *Bolt on mounting For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 75 Medium Voltage Fuses E-rated Fuses: CL-14 & Bolt-In ECL055 Specifications Description: E-rated medium voltage, current-limiting fuses for transformer and feeder protection. Construction: Filament wound, glass epoxy fuse tube, with silica filler, and silver-plated copper terminals and endcaps containing a silver element in a double concentric helical configuration. Ratings: Volts: -- 5.5kV Amps: -- 10-900A IR: -- 63kA Sym. Max Agency Information: Meets E requirements per ANSI C37.46, Meets General Purpose requirements per ANSI C37.40. Features and Benefits * Clip-lock and bolt-in style available in double and triple barrel fuse designs for application flexibility * The filament wound, glass epoxy fuse tube provides UV and moisture protection, making these medium voltage fuses suitable for both indoor and outdoor applications * Open fuse indication (indicator travel distance is 16mm) easily integrates into automation schemes * 50/60Hz operating frequency make these fuses applicable world-wide * * * * Typical Applications 5.0kV Transformer Primary Protection 5.0kV Feeder Circuit Protection 5.0kV Voltage Switches 5.0kV Metal-enclosed Switchgear Catalog Numbers Catalog Numbers ECL055-10E ECL055-15E ECL055-20E ECL055-25E ECL055-30E ECL055-40E ECL055-50E ECL055-65E ECL055-80E ECL055-100E ECL055-125E ECL055-150E ECL055-200E ECL055-250E ECL055-300E ECL055-400E ECL055-450E ECL055-500E ECL055-600E ECL055-750E ECL055-900E Amp Rating 10 15 20 25 30 40 50 65 80 100 125 150 200 250 300 400 450 500 600 750 900 Voltage 5.5kV - - - - - - - - - - - - - - - - - - - - IR Max Sym. 63kA # of Barrels 1 Style Clip-Lock 1 Clip-Lock 2 Clip-Lock 3 Bolt-In Bolt-In 63kA 2 3 Catalog Number Construction (Example) Catalog Number ECL Voltage Rating 055 055 = 5.5 kV Amp Rating 500E Catalog Number Cross Reference Cooper Bussmann Catalog Numbers ECL055-10E ECL055-15E ECL055-20E ECL055-25E ECL055-30E ECL055-40E ECL055-50E ECL055-65E ECL055-80E ECL055-100E ECL055-125E ECL055-150E ECL055-200E ECL055-250E ECL055-300E ECL055-400E ECL055-450E ECL055-500E ECL055-600E ECL055-750E ECL055-900E Ferraz-Shawmut New Catalog # A055C1DORO-10E A055C1DORO-15E A055C1DORO-20E A055C1DORO-25E A055C1DORO-30E A055C1DORO-40E A055C1DORO-50E A055C1DORO-65E A055C1DORO-80E A055C1DORO-100E A055C1DORO-125E A055C1DORO-150E A055C1DORO-200E A055C1DORO-250E A055C1DORO-300E A055C1DORO-400E A055C2DORO-450E A055C2DORO-500E A055C2DORO-600E A055B3DORO-750E A055B3DORO-900E Data Sheet: 9002 76 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Ferraz-Shawmut Old Catalog # 225-007-937 225-007-938 225-007-939 225-007-940 225-007-941 225-007-942 225-007-943 225-007-944 225-007-945 225-007-946 225-007-947 225-007-948 225-007-949 225-007-950 225-007-951 225-007-952 225-007-953 225-007-954 225-007-955 A055X750E-4 A055X900E-4 Medium Voltage Fuses E-rated Fuses: CL-14 ECL155 Features and Benefits * Clip-lock double barrel fuse design assures positive installation * The filament wound, glass epoxy fuse tube provides UV and moisture protection, making these medium voltage fuses suitable for both indoor and outdoor applications * Open fuse indication (indicator travel distance is 16mm) easily integrates into automation schemes * 50/60 Hz operating frequency make these fuses applicable world-wide * * * * Typical Applications 15.0kV Transformer Primary Protection 15.0kV Feeder Circuit Protection 15.0kV Voltage Switches 15.0kV Metal-enclosed Switchgear Catalog Numbers Catalog Numbers ECL155-10E ECL155-15E ECL155-20E ECL155-25E ECL155-30E ECL155-40E ECL155-50E ECL155-65E ECL155-80E ECL155-100E ECL155-125E ECL155-150E ECL155-200E ECL155-250E ECL155-300E Amp Rating 10 15 20 25 30 40 50 65 80 100 125 150 200 250 300 Voltage 15.5kV IR Voltage Max Sym. 63KA # of Barrels 1 Style Clip-Lock 1 63kA 15.5kV Clip-Lock 2 50kA 50kA 2 Catalog Number Construction (Example) Catalog Number ECL Voltage Rating 155 155 = 15.5 kV Amp Rating 300E Catalog Number Cross Reference Cooper Bussmann Catalog Numbers ECL155-10E ECL155-15E ECL155-20E ECL155-25E ECL155-30E ECL155-40E ECL155-50E ECL155-65E ECL155-80E ECL155-100E ECL155-125E ECL155-150E ECL155-200E ECL155-250E ECL155-300E Ferraz-Shawmut New Catalog # A155C1DORO-10E A155C1DORO-15E A155C1DORO-20E A155C1DORO-25E A155C1DORO-30E A155C1DORO-40E A155C1DORO-50E A155C1DORO-65E A155C1DORO-80E A155C1DORO-100E A155C2DORO-125E A155C3DORO-150E A155C3DORO-200E A155C3DORO-250E A155C3DORO-300E Ferraz-Shawmut Old Catalog # 225-007-967 225-007-968 225-007-969 225-007-970 225-007-971 225-007-972 225-007-973 225-007-974 225-007-975 225-007-976 225-007-977 225-007-978 225-007-979 225-007-980 225-007-981 Data Sheet: 9004 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 77 Medium Voltage Fuses Specifications Description: E-rated medium voltage, current-limiting fuses for transformer and feeder protection. Construction: Filament wound, glass epoxy fuse tube, with silica filler, and silver-plated copper terminals and endcaps containing a silver element in a double concentric helical configuration. Ratings: Volts: -- 15.5kV Amps: -- 10-300A IR: -- 63kA Sym. (10-200A) -- 50kA Sym. (250-300A) Agency Information: Meets E requirements per ANSI C37.46, Meets General Purpose requirements per ANSI C37.40. Medium Voltage Fuses E-rated Fuses for Potential & Small Power Transformers JCD, JCW, JCQ, JCI & JCT Features and Benefits * Sized for retrofitting in existing hardware * Space saving size Specifications Description: Indicating and nonindicating E-rated medium voltage, current-limiting fuses for potential and small power transformers. Dimensions: See Catalog Numbers table. Construction: Plated ferrules. Ratings: Volts: -- 2.4-15.5kV (See Catalog Numbers table for details) Amps: -- 12-10A IR: -- 25-80kA Sym -- 40-130kA ASYM -- See Catalog Numbers table for details Typical Applications * Primary protection of medium voltage potential transformers * Primary protection of small medium voltage service transformers * Primary protection of small medium voltage control transformers Catalog Numbers Catalog Numbers Amp Rating Maximum Design Voltage IR RMS Sym. Dimensions - in (mm) Length Diameter 2400V; E-Rated Fuse; Non-Indicating JCD-12E JCD-1E JCD-2E JCD-5E 0.5 1 2 5 2.75kV 2.75kV 2.75kV 2.75kV 63kA 40kA 40kA 25kA 4.50 4.50 4.50 4.50 (114) (114) (114) (114) 0.80 0.80 0.80 0.80 (20.32) (20.32) (20.32) (20.32) 2450/5500V; E-Rated Fuse; Non-Indicating JCW-12E JCW-1E JCW-2E JCW-3E JCW-5E 0.5 1 2 3 5 2.75/5.5kV 2.75/5.5kV 2.75/5.5kV 2.75/5.5kV 2.75/5.5kV 40kA 40kA 40kA 40kA 40kA 7.312 7.312 7.312 7.312 7.312 (185.72) (185.72) (185.72) (185.72) (185.72) 1.563 1.563 1.563 1.563 1.563 (39.70) (39.70) (39.70) (39.70) (39.70) 80kA 80kA 80kA 80kA 80kA 80kA 9.5 9.5 9.5 9.5 9.5 9.5 (241.3) (241.3) (241.3) (241.3) (241.3) (241.3) 1.6 1.6 1.6 1.6 1.6 1.6 (40.64) (40.64) (40.64) (40.64) (40.64) (40.64) 80kA 80kA 50kA 50kA 9.5 (241.3) 12.88 (327.15) 12.88 (327.15) 12.88 (327.15) 1.6 1.6 1.6 1.6 (40.64) (40.64) (40.64) (40.64) 80kA 80kA 80kA 80kA 80kA 80kA 12.93 (328.42) 12.93 (328.42) 12.93 (328.42) 17.5 (444.5) 17.5 (444.5) 17.5 (444.5) 1.6 1.6 1.6 1.6 1.6 1.6 (40.64) (40.64) (40.64) (40.64) (40.64) (40.64) 5500V; E-Rated Fuse; Indicating JCQ-12E JCQ-1E JCQ-112E JCQ-3E JCQ-5E JCQ-10E 0.5 1 1.5 3 5 10 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 8300V; E-Rated Fuse; Indicating JCI-12E JCI-3E JCI-5E JCI-10E 0.5 3 5 10 8.3kA 8.3kA 8.3kA 8.3kA 15,500V; E-Rated Fuse; Indicating JCT-12E JCT-1E JCT-1-12E JCT-3E JCT-5E JCT-10E 0.5 1 1.5 3 5 10 15.5kV 15.5kV 15.5kV 15.5kV 15.5kV 15.5kV Fuse clip for 1.56 and 1.6 inch diameter fuses - 1A0835. Fuse clip for 0.81 inch diameter fuses - 1A1837. Data Sheet: 6002 78 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Medium Voltage Fuses E-rated Fuses for Potential & Small Power Transformers AB, AD, AM and CAV Ratings: Volts: -- 5.5-38kV Amps: -- 0.5-15A IR: -- 40kA-80kA Sym. -- See Catalog Numbers table for details Typical Applications * Primary protection of medium voltage potential transformers * Primary protection of small medium voltage service transformers * Primary protection of small medium voltage control transformers Catalog Numbers Catalog Numbers Amp Rating 5.5ABWNA0.5E 5.5ABWNA1E 5.5ABWNA2E 5.5ABWNA3E 5.5ABWNA5E 5.5AMWNA0.5E 5.5AMWNA1.0E 5.5AMWNA2.0E 5.5AMWNA3.0E 5.5AMWNA4.0E 5.5AMWNA5.0E 5.5CAVH0.5E 5.5CAVH1E 5.5CAVH2E 5.5CAV15E 7.2AMWNA0.5E 7.2AMWNA1.0E 7.2AMWNA2.0E 7.2AMWNA3.0E 7.2AMWNA4.0E 7.2AMWNA5.0E 15.5CAV(H)0.5E* 15.5CAV(H)1E* 15.5CAV(H)2E* 15.5CAV3E 15.5CAV5E 15.5CAV7E 38ADMNA7E 38ADMNA10E 38CAV(H)0.5E* 38CAV(H)1E* 38CAV(H)2E* 38CAV4E 0.5 1 2 3 5 0.5 1.5 2.5 3.5 4.5 5.5 0.5 1 2 15 0.5 1 2 3 4 5 0.5 1 2 3 5 7 7 10 0.5 1 2 4 Maximum Design Voltage 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 7.2kV 7.2kV 7.2kV 7.2kV 7.2kV 7.2kV 15.5kV 15.5kV 15.5kV 15.5kV 15.5kV 15.5kV 38kV 38kV 38KV 38KV 38KV 38KV IR RMS Sym. 50kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA 63kA 63kA 63kA 63kA 50kA 50kA 50kA 50kA 50kA 50kA 80kA 80kA 80kA 80kA 80kA 80kA 40kA 40kA 40kA 40kA 40kA 40kA Dimensions - in (mm) Length Diameter 5.6 (142.2) 5.6 (142.2) 5.6 (142.2) 5.6 (142.2) 5.6 (142.2) 5.6 (142.2) 5.6 (142.2) 5.6 (142.2) 5.6 (142.2) 5.6 (142.2) 5.6 (142.2) 7.375 (187.3) 7.375 (187.3) 7.375 (187.3) 7.375 (187.3) 5.6 (142.2) 5.6 (142.2) 5.6 (142.2) 5.6 (142.2) 5.6 (142.2) 5.6 (142.2) 12.87 (326.9) 12.87 (326.9) 12.87 (326.9) 12.87 (326.9) 12.87 (326.9) 12.87 (326.9) 17.4 (442) 17.4 (442) 17.32 (439.9) 17.32 (439.9) 17.32 (439.9) 17.32 (439.9) 1 (25.4) 1 (25.4) 1 (25.4) 1 (25.4) 1 (25.4) 0.81 (20.6) 0.81 (20.6) 0.81 (20.6) 0.81 (20.6) 0.81 (20.6) 0.81 (20.6) 1.63 (41.4) 1.63 (41.4) 1.63 (41.4) 1.63 (41.4) 0.81 (20.6) 0.81 (20.6) 0.81 (20.6) 0.81 (20.6) 0.81 (20.6) 0.81 (20.6) 1.63 (41.4) 1.63 (41.4) 1.63 (41.4) 1.63 (41.4) 1.63 (41.4) 1.63 (41.4) 2 (50.8) 2 (50.8) 1.63 (41.4) 1.63 (41.4) 1.63 (41.4) 1.63 (41.4) *Type CAVH fuses are fitted with a striker pin for indication. Omit `H' for non-indicating fuses. Fuseclip for 0.8 inch diameter fuses - 1A1837. Fuseclip for 1 inch diameter fuses - A3354705. Fuseclip for 1.6 inch diameter fuses - 1A0835. For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 79 Medium Voltage Fuses Specifications Description: Indicating and non-indicating E-rated medium voltage, current-limiting fuses for potential and small power transformers. Dimensions: See Catalog Numbers table. Features and Benefits * Sized for retrofitting in existing hardware * Space saving size Medium Voltage Fuses R-rated Fuses for Motor Circuit Protection JCG, JCH, JCK, JCK-A, JCK-B, JCL, JCL-A, JCL-B, JCR-A, & JCR-B Specifications Description: Indoor/enclosure R-rated medium voltage, current-limiting fuses for motor circuit protection. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 2.4-7.2kV (See Catalog Numbers table for details) Amps: -- 25-450A (See Catalog Numbers table for details) IR: -- 50kA Sym -- 80kA ASYM -- See Catalog Numbers table for details Agency Information: UL Recognized: 2540Vac -- JCK, JCK-A, 5080Vac -- JCL, JCL-A, UL Recognized (Guide #MSSS2, File #E96676). Features and Benefits * Physically dimensioned for retrofitting in existing hardware * Open fuse indicator for ease in troubleshooting * Available with optional Cutler Hammer(R) hookeye for ease of insertion and removal * Classified as back-up fuses for current-limited protection of medium voltage motor controllers Typical Applications * Medium Voltage Motor Controllers Dimensions - mm (in) Figure 1 INDICATOR Showing Fuse is Open 0.38" (9.5mm) C A INDICATOR Showing Fuse is Open B Figure 2 Figure 3 Data Sheet 6001 80 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Medium Voltage Fuses R-rated Fuses for Motor Circuit Protection Catalog Numbers: R-Rated; Indoor/Enclosure Catalog Numbers Amp Ratings Maximum Design Voltage A Dimensions - in (mm)* B Construction C Max Int. Cap. Amps (Asym.) Amps (Sym.) Min Int. Cap. Amps (Sym.) 2400V (See Figure 1) JCK-2R JCK-3R JCK-4R JCK-5R JCK-6R JCK-9R JCK-12R JCK-18R JCK-24R 70 100 130 150 170 200 230 390 450 2540 2540 2540 2540 2540 2540 2540 2540 2540 11.24 11.24 11.24 11.24 11.24 11.24 11.24 11.24 11.24 (285.5) (285.5) (285.5) (285.5) (285.5) (285.5) (285.5) (285.5) (285.5) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 165 220 320 410 480 720 970 1,430 1,880 Single Single Single Single Single Single Single Double Double 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 165 220 320 410 480 720 970 1,430 1,880 Single Single Single Single Single Single Single Single Double Double 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 90 170 245 340 430 500 1,000 1,250 1,700 1,210 Medium Voltage Fuses Single Single Single Single Single Single Single Double Double 2400V -- With Westinghouse Ampguard Hookeye (See Figure 1) JCK-A-2R JCK-A-3R JCK-A-4R JCK-A-5R JCK-A-6R JCK-A-9R JCK-A-12R JCK-A-18R JCK-A-24R 70 100 130 150 170 200 230 390 450 2540 2540 2540 2540 2540 2540 2540 2540 2540 11.24 11.24 11.24 11.24 11.24 11.24 11.24 11.24 11.24 (285.5) (285.5) (285.5) (285.5) (285.5) (285.5) (285.5) (285.5) (285.5) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) 2400V -- Bolt-On (See Figures 2 & 3) JCK-B-30 JCK-B-2R JCK-B-3R JCK-B-4R JCK-B-5R JCK-B-6R JCK-B-9R JCK-B-12R JCK-B-18R JCK-B-24R 25 70 100 130 150 170 200 230 390 450 2540 2540 2540 2540 2540 2540 2540 2540 2540 2540 14.18 14.18 14.18 14.18 14.18 14.18 14.18 14.18 14.18 14.18 (360.2) (360.2) (360.2) (360.2) (360.2) (360.2) (360.2) (360.2) (360.2) (360.2) 12.81 12.81 12.81 12.81 12.81 12.81 12.81 12.81 12.81 12.81 (325.4) (325.4) (325.4) (325.4) (325.4) (325.4) (325.4) (325.4) (325.4) (325.4) 3.56 (90.4) 3.56 (90.4) 2400V -- Hermetically Sealed, For Use with Ampguard Motor Starters (See Figure 1) JCH-30 JCH-2R JCH-3R JCH-4R JCH-5R JCH-6R JCH-9R JCH-12R JCH-18R JCH-24R 25 70 100 130 150 170 200 230 390 450 2540 2540 2540 2540 2540 2540 2540 2540 2540 2540 10.81 10.81 10.81 10.81 10.81 10.81 10.81 10.81 10.81 10.81 (275.6) (275.6) (275.6) (275.6) (275.6) (275.6) (275.6) (275.6) (275.6) (275.6) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) Single Single Single Single Single Single Single Single Double Double 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 90 170 245 340 430 500 1,000 1,250 1,700 2,100 15.76 15.76 15.76 15.76 15.76 15.76 15.76 15.76 15.76 (400.3) (400.3) (400.3) (400.3) (400.3) (400.3) (400.3) (400.3) (400.3) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) Single Single Single Single Single Single Single Double Double 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 165 220 320 410 480 720 970 1,430 1,880 4800V (See Figure 1) JCL-2R JCL-3R JCL-4R JCL-5R JCL-6R JCL-9R JCL-12R JCL-18R JCL-24R 70 100 130 150 170 200 230 390 450 5080 5080 5080 5080 5080 5080 5080 5080 5080 * See previous page Figure 2 for single construction and Figure 3 for double construction information. Recommended fuseclips: see page 91 - 1A0065, A3354730, 9078A67G04. Data Sheet: 6001 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 81 Medium Voltage Fuses R-rated Fuses for Motor Circuit Protection Catalog Numbers: R-Rated; Indoor/Enclosure Catalog Numbers Amp Ratings Maximum Design Voltage A Dimensions - in (mm) B C Max Int. Cap. Amps (Asym. Amps (Sym.) Single Single Single Single Single Single Single Double Double 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 165 220 320 410 480 720 970 1,430 1,880 Single Single Single Single Single Single Single Single Double Double 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 95 180 270 350 450 540 700 1,000 1,450 2,000 Con nstruction Min Int. Cap. Amps (Sym.) 4800V -- With Westinghouse Ampguard Hookeye (See Figure 1) JCL-A-2R JCL-A-3R JCL-A-4R JCL-A-5R JCL-A-6R JCL-A-9R JCL-A-12R JCL-A-18R JCL-A-24R 70 100 130 150 170 200 230 390 450 5080 5080 5080 5080 5080 5080 5080 5080 5080 15.76 15.76 15.76 15.76 15.76 15.76 15.76 15.76 15.76 (400.3) (400.3) (400.3) (400.3) (400.3) (400.3) (400.3) (400.3) (400.3) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) 4800V -- Bolt-On (See Figures 2 & 3) JCL-B-30 JCL-B-2R JCL-B-3R JCL-B-4R JCL-B-5R JCL-B-6R JCL-B-9R JCL-B-12R JCL-B-18R JCL-B-24R 30 70 100 130 150 170 200 230 390 450 5080 5080 5080 5080 5080 5080 5080 5080 5080 5080 19.25 19.25 19.25 19.25 19.25 19.25 19.25 19.25 19.25 19.25 (488.9) (488.9) (488.9) (488.9) (488.9) (488.9) (488.9) (488.9) (488.9) (488.9) 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 (454.1) (454.1) (454.1) (454.1) (454.1) (454.1) (454.1) (454.1) (454.1) (454.1) 3.31 (84.1) 3.31 (84.1) 4800V -- Hermetically Sealed, For Use with Ampguard Motor Starters (See Figure 1) JCG-30 JCG-2R JCG-3R JCG-4R JCG-5R JCG-6R JCG-9R JCG-12R JCG-A-18R JCG-A-24R 30 70 100 130 150 170 200 230 390 450 5080 5080 5080 5080 5080 5080 5080 5080 5080 5080 15.91 15.91 15.91 15.91 15.91 15.91 15.91 15.91 15.91 15.91 (404.1) (404.1) (404.1) (404.1) (404.1) (404.1) (404.1) (404.1) (404.1) (404.1) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) Single Single Single Single Single Single Single Single Double Double 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 95 180 270 350 450 540 700 1,000 1,450 2,000 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) Single Single Single Single Single Single Single Double Double 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 160 250 325 390 500 750 1,000 1,450 2,500 Single Single Single Single Single Single Single Double Double 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 160 250 325 390 500 750 1,000 1,450 2,500 7200V -- With Ampguard Hookeye (See Figure 1) JCR-A-2R JCR-A-3R JCR-A-4R JCR-A-5R JCR-A-6R JCR-A-9R JCR-A-12R JCR-A-18R JCR-A-24R 70 100 130 150 170 200 230 390 450 8300 8300 8300 8300 8300 7200 7200 7200 7200 15.85 15.85 15.85 15.85 15.85 15.85 15.85 15.85 15.85 (402.6) (402.6) (402.6) (402.6) (402.6) (402.6) (402.6) (402.6) (402.6) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) (76.2) 7200V -- Bolt-On (See Figures 2 & 3) JCR-B-2R JCR-B-3R JCR-B-4R JCR-B-5R JCR-B-6R JCR-B-9R JCR-B-12R JCR-B-18R JCR-B-24R 70 100 130 150 170 200 230 390 450 8300 8300 8300 8300 8300 7200 7200 7200 7200 19.25 19.25 19.25 19.25 19.25 19.25 19.25 19.25 19.25 (488.9) (488.9) (488.9) (488.9) (488.9) (488.9) (488.9) (488.9) (488.9) 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 17.88 (454.1) (454.1) (454.1) (454.1) (454.1) (454.1) (454.1) (454.1) (454.1) 3.31 (84.1) 3.31 (84.1) Recommended fuseclips: see page 91 - 1A0065, A3354730, 9078A67G04. Data Sheet: 6001 82 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Medium Voltage Fuses British Standard Dimensioned IEC Fuses for Motor Circuit Protection The Cooper Bussmann range of motor fuses are designed to meet the specific requirements necessary for motor protection. During the starting cycle of direct on-line motors, the fuse elements will reach a considerably higher temperature than during normal operation; (this is due to the high amount of current the motor will draw as it starts, typically, six times its normal load current value). This results in expansion and contraction of the fuse elements and could cause premature operation of the fuse. Medium Voltage Fuses Cooper Bussmann motor fuses encompass an advanced design to minimize this effect. This therefore, negates the need to over specify the fuse rating due to high values of motor starting current. Cooper Bussmann motor fuses operate extremely quickly under heavy fault currents, resulting from the time / current characteristic. Low power dissipation ensures low temperature rise, important in multi-tier starters for example. Switching (arc), voltages are lower than permitted values, therefore, 5.5kV fuses are also suitable for 4.8kV and 2.4kV circuits. Table of Ratings Basic Cat. Number 3.6WJON6 3.6WDOH6 3.6WFOH6 3.6WDLSJ 3.6WFLSJ 3.6WDFHO 3.6WFFHO 3.6WKFHO 5.5VFNHA 5.5VKNHA 7.2WFNHO 7.2WKNHO 7.2WFMSJ 7.2WKMSJ Volts 3.6kV 3.6kV 3.6kV 3.6kV 3.6kV 3.6kV 3.6kV 3.6kV 5.5kV 5.5kV 7.2kV 7.2kV 7.2kV 7.2kV Breaking Capacity 50kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA 60kA 60kA 40kA 40kA 63kA 63kA Amp Ratings 5, 6.3, 10, 16, 20, 25, 31.5, 40, 50 50, 63, 80, 100, 125 160, 200 50, 63, 80, 100, 125 160, 200 50, 63, 80, 100, 125 160, 200 250, 315, 355, 400 2R-6R 9R-24R 25, 31.5, 40, 50, 63, 80, 100, 125, 160 200, 224, 250, 315 25, 31.5, 40, 50, 63, 80, 125, 160 200, 224, 250, 315, 355 Catalog Number Build-A-Code kV Basic Catalog Number ___ _____ Dimensions - in (mm) Length Diameter 7.56 (192) 1.4 (35.6) 7.56 (192) 2 (50.8) 7.56 (192) 3 (76.2) 11.5 (292.1) 2 (50.8) 11.5 (292.1) 3 (76.2) 10 (254) 2 (51) 10 (254) 3 (76.2) 10 (254) 3 (76.2) 15.86 (402.8) 3 (76.2) 15.86 (402.8) 3 (76.2) 15.86 (402.8) 3 (76.2) 15.86 (402.8) 3 (76.2) 17.40 (442) 3 (76.2) 17.40 (442) 3 (76.2) Dimensional Stand dard BS 2692 (TA1) Interchangeable with GEC type K2 PA BS 2692 (TA1) or DIN 43625 BS 2692 (TA1) or DIN 43625 DIN 43625 DIN 43625 BS 2692 (TA2) BS 2692 (TA2) BS 2692 (TA2) ANSI R-rated ANSI R-rated BS 2692 (TA4) BS 2692 (TA4) DIN 43625 DIN 43625 Amps ___ For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 83 Medium Voltage Fuses DIN Dimensioned IEC Fuses for Transformer Protection DIN Dimension Fuses To Spec. DIN 43625 Specifications Catalog Symbol: See Basic Catalog Numbers table. Description: DIN dimension fuses to Specification DIN 43625 covering current-limiting fuses with performance in compliance with IEC 60282-1. These are in accordance with the R10 and, in some cases, the R20 series of preferred numbers. Dimensions: See Catalog Numbers table. Catalog Number Build-A-Code kV Basic Catalog Number ___ _____ Amps ___ Volts: -- See voltage associated with the Basic Catalog Numbers in the table. Amps: -- See amp rating associated with the Basic Catalog Numbers in the table. IR: -- See IR associated with the Basic Catalog Numbers in the table. Agency Information: Comply with DIN dimensional standard DIN 43625, VDE 0670 part 4, VDE 0670 part 40Z and with IEC 60282-1 (2005). Features and Benefits * DIN dimensioned for retrofitting in existing hardware * Open fuse indicator for ease in troubleshooting * Designed for use in IEC equipment Typical Applications * Medium Voltage IEC designed equipment Catalog Numbers kV 3.6 7.2 12 17.5 24 36 Catalog Numbers 3.6ADOSJ(amp) 3.6WDOSJ(amp) 3.6WFOSJ(amp) 3.6ADLSJ(amp) 3.6WDLSJ(amp) 3.6WFLSJ(amp) 3.6WKLSJ(amp) 7.2TDLSJ(amp) 7.2TFLSJ(amp) 7.2WKMSJ(amp) 12TDLEJ(amp) 12THLEJ(amp) 12TKLEJ(amp) 12TXLEJ(amp)* 17.5TDLSJ(amp)* 17.5TFLSJ(amp)* 17.5TDMEJ(amp) 17.5THMEJ(amp) 17.5TKMEJ(amp) 24TDMEJ(amp) 24THMEJ(amp) 24TFMEJ(amp) 24TXMEJ(amp)* 36TDQSJ(amp) 36TFQSJ(amp) 36TXQEJ(amp)* Amp Ratings 6.3, 10, 16, 20, 25, 31.5, 40 50, 63, 80, 100, 125 160, 200 25, 40 50, 63, 80, 100, 125 160, 200 250, 315, 400 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63 80, 100, 125, 160 200, 225, 250, 315, 355 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63 80, 100 125 160, 200 6.3, 10, 16, 20, 25, 31.5, 40 50 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63 80, 100 125 6.3, 10, 16, 20, 25, 31.5, 40, 50 63 80, 100*1 1252, 160 3.153, 6.3, 10, 16, 20, 25 31.5, 40, 50 63 Dimensions - in (mm) Diameter x Length 2.00 x 7.56 (51 x 192) 2.00 x 7.56 (51 x 192) 3.00 x 7.56 (76 x 192 2.00 x 11.50 (51 x 292) 2.00 x 11.50 (51 x 292) 3.00 x 11.50 (76 X 292) 3.00 x 11.50 (76 X 292) 2.00 x 11.50 (51 x 292) 3.00 x 11.50 (76 x 292) 3.00 x 17.41 (76 x 442) 2.00 x 11.50 (51 x 292) 2.52 x 11.50 (64 x 292) 3.00 x 11.50 (76 x 292) 3.50 x 11.50 (88 x 292) 2.00 x 11.50 (51 x 292) 3.00 x 11.50 (76 x 292) 2.00 x 17.41 (51 x 442) 2.52 x 17.41 (64 x 442) 3.00 x 17.41 (76 x 442) 2.00 x 17.41 (51 x 442) 2.52 x 17.41 (64 x 442) 3.00 x 17.41 (76 x 442) 3.46 x 17.41 (88 x 442) 2.00 x 21.16 (51 x 537) 3.00 x 21.16 (76 x 537) 3.46 x 21.16 (88 x 537) IR RMS Sym 40kA 50kA 40kA 63kA 35.5kA 50kA 50kA 31.5kA 35.5kA 20kA Recommended fuseclips for DIN style fuses - 270303, A3354745 see page 91. *Not compliant with VDE 0670, part 402. 1 -IR RMS Sym is 63kA 2 -IR RMS Sym is 40kA 3 -IR RMS Sym is 20kA Dimensions - In (mm) Diameter Striker In Operated Position 0.59" 15.0mm 1.77" 45.0mm Length For Diameter and Length Dimensions See Table Above 84 1.02" 1.34" 34.0mm 26.0mm For detailed information, visit the Electrical IEC section at www.cooperbussmann.com Medium Voltage Fuses Potential Transformer Fuses AB, AM and CAV Ratings: E-Rated: -- See single asterisk in Basic Catalog Numbers table Volts: -- 3.6-38kV (See Basic Catalog Numbers table) Amps: -- 2-15A (See Basic Catalog Numbers table) IR: -- 25-80kA (See Basic Catalog Numbers table) Agency Information: BS2692-1 and IEC60282-1 Features and Benefits * Physically dimensioned for retrofitting in existing hardware. * Space saving size. Medium Voltage Fuses Specifications Description: British Standard VT fuses with low current ratings for use in voltage transformers or operating transformers to provide isolation of the associated system in the event of faults in the transformer circuit. Dimensions: See Basic Catalog Numbers table. Typical Applications * Medium Voltage Potential Transformers * Small Medium Voltage Service Transformers Basic Catalog Numbers for "AB" & "AM" Series Basic Cat. Numbers 3.6ABWNA 3.6ABCNA 5.5ABWNA* 5.5AMWNA* 7.2ABWNA 7.2ABCNA 12ABCNA 15.5ABFNA 17.5ABGNA 24ABGNA 36ABGNA** Volts 3.6kV 3.6kV 5.5kV 5.5kV 7.2kV 7.2kV 12.0kV 15.5kV 17.5kV 24.0kV 36.0kV Amp Ratings 3.15, 6.3 3.15, 6.3, 10 0.5, 1, 2, 3, 5 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 3.15, 6.3 3.15, 6.3 3.15 3.15 3.15 3.15 3.15 Dimensions - in (mm) Length Diameter 5.6 (142.2) 1 (25.4) 7.69 (195.3) 1 (25.4) 5.6 (142.2) 1 (25.4) 5.6 (142.2) 0.81 (20.6) 5.6 (142.2) 1 (25.4) 7.69 (195.3) 1 (25.4) 7.69 (195.3) 1 (25.4) 10.00 (254) 1 (25.4) 14.13 (358.9) 1 (25.4) 14.13 (358.9) 1 (25.4) 14.13 (358.9) 1 (25.4) Type AB AB AB AM AB AB AB AB AB AB AB IR 50KA 50KA 50KA 50KA 45KA 45KA 45KA 32KA 35KA 25KA 31.5KA Recommended fuse clip for 1 diameter fuses - A3354705. Basic Catalog Numbers for "CAV" Series Basic Cat. Number 3.6CAV 5.5CAV* 5.5CAVH* 7.2CAV 12CAV 15.5CAV* 15.5CAVH* 17.5CAV 24CAV 36CAV 36CAVH 38CAV* 38CAVH* Volts 3.6kV 5.5kV 5.5kV 7.2kV 12kV 15.5kV 15.5kV 17.5kV 24kV 36kV 36kV 38kV 38kV Amp Ratings 2 15 0.5, 1, 2 2, 4, 6, 10 2 0.5, 1, 2, 3, 5, 7 0.5, 1, 2 2, 4, 6, 10 2, 3, 4 2, 4 2 4 0.5, 1, 2 Dimensions - in (mm) Length Diameter 8.66 (220) 1.63 (41.4) 7.375 (187.3) 1.63 (41.4) 7.375 (187.3) 1.63 (41.4) 8.66 (220) 1.63 (41.4) 8.66 (220) 1.63 (41.4) 12.87 (326.9) 1.63 (41.4) 12.87 (326.9) 1.63 (41.4) 8.66 (220) 1.63 (41.4) 13.39 (340.1) 1.63 (41.4) 17.32 (439.9) 1.63 (41.4) 17.32 (439.9) 1.63 (41.4) 17.32 (439.9) 1.63 (41.4) 17.32 (439.9) 1.63 (41.4) IR 50KA 63KA 63KA 63KA 40KA 80KA 80KA 40KA 40KA 40KA 40KA 40KA 40KA Type CAVH are fitted with a striker pin for indication. * E-Rated fuses **For clean indoor applications only. Catalog Number Build-A-Code kV Basic Catalog Number ___ _____ Amps ___ Recommended Fuse Clips: 1" dia. - A3354705, 1.63" dia. - 1A0835, .819 dia. - 1A1837 Contact Cooper Bussmann for complete specifications on potential transformer fuses For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 85 Medium Voltage Fuses British Standard IEC Fuses for Use in Oil Filled Distribution Switchgear OEFMA Code Number Reference Specifications Description: BS 2692-1 medium voltage fuses for use on the primary circuit of three-phase 50Hz transformers in oil field switchgear. Fitted with powerful pyrotechnic striker pin. Ratings: Volts: -- 3.6-24kV Amps: -- 6.3-200A IR: -- 25-50kA (See Catalog Number table below) Agency Information: Fuses comply with IEC 60282-1, BS2692-1 and ESI Standard 12-8. 7.2 and 12kV fuses tested at highest system voltage and approved by the UK Electricity Association approvals panel. O _ _ M A Type O = Oil tight Diameter E = 63.5mm H = 63.5mm L = 63.5mm Length F = 254mm G = 359mm Striker M = As specified in BS 2692 table 11 Tags A = None (plain caps) Dimensions: Current-limiting fuse for use in oil switchgear Featues and Benefits * Physically sized for replacement of British Standard fuse links Fuse types: OEF, OEG, OHF, OHG, OLG 254mm (10 in) or 359mm (14 in) 68 Max 63.5 44 Typical Applications * Medium Voltage BS Designed Equipment 10 Min -- 16 Max striker travel after operation, if fitted. Catalog Numbers Transformer kVA 200 250 300/315 400 500 630 750/800 1000 1250 1600 Catalog Numbers/Transformer Primary Voltage 3.3kV 3.6OEFMA63 3.6OEFMA80 3.6OEFMA100 3.6OEFMA125 3.6OEFMA160 3.6OEFMA200 3.6OLGMA250 3.6OLGMA250* -- -- 6.6kV 12OEFMA31.5 12OEFMA40 12OEFMA50 12OEFMA63 12OHFMA71 7.2OEFMA100 7.2OHGMA125 7.2OHGMA140 7.2OHGMA160* -- 11kV/ESI 12-8 Ref. 12OEFMA25/01 12OEFMA25/-- 12OEFMA31.5/02 12OEFMA40/-- 12OEFMA50/03 12OEFMA63/-- 12OHFMA80/04 12OHGMA90**/05 12OHGMA100/-- 12OLGMA125*/-- 13.8kV 15.5OEFMA16 15.5OEFMA20 15.5OEFMA25 15.5OEFMA31.5 15.5OEFMA40 15.5OEFMA50 15.5OEFMA63 15.5OHGMA71 15.5OHGMA90 15.5OLGMA100* This Catalog Number selection table is based upon the following criteria: 1. Withstand against magnetizing inrush current taken as 12 times full-load current for 0.1 second. 2. Withstand against 150% permissible overload current. Recommendations marked with asterisks have the following significance:*Limited to permissible overloads of 130%. **Permits use of a 12kV OHFMA 80A fuse with a 100kVA transformer where permissible overload does not exceed 130%. 3. For 6.6kV systems, 12kV fuses are recommended where possible in the interests of standardization. 4. Wherever possible, 10 inch long FO1 fuses are offered rather than equivalent 14 inch FO2 types. 5. The above recommendations are not generally applicable to transformers feeding motor circuits with starting currents in excess of the transformer full load current. In this event, please consult Cooper Bussmann. Catalog Numbers Basic Cat. Number 3.6OEFMA 3.6OEGMA 3.6OLGMA 7.2OEFMA 7.2OHGMA 12OEFMA 12OHFMA 12OHGMA 12OLGMA 15.5OEFMA 15.5OHGMA 15.5OLGMA 17.5OHGMA 24OEGMA Voltage 3.6kV 3.6kV 3.6kV 7.2kV 7.2kV 12.0kV 12.0kV 12.0kV 12.0kV 15.5kV 15.5kV 15.5kV 17.5kV 24.0kV Dimensional Ref. BS 2692 FO1 FO2 FO2 FO1 FO2 FO1 FO1 FO2 FO2 FO1 FO2 FO2 FO2 FO2 Amp Ratings 6.3, 10, 16, 20, 25, 100, 125, 160, 200 250 80, 100, 112 125, 140, 160 6.3, 10, 16, 20, 25, 71, 80 6.3, 10, 16, 20, 25, 125 6.3, 10, 16, 20, 25, 71, 80, 90 100 6.3, 10, 16, 20, 25, 6.3, 10, 16, 20, 25, Breaking Capacity (kA) 31.5, 40, 50, 63, 80, 100, 125, 160, 200 50 50 50 45 45 31.5, 40, 50, 63 40 40 31.5, 40, 50, 63, 71, 80, 90, 100 40 40 31.5, 40, 50, 63 40 40 40 31.5, 40, 50, 63, 80 35 31.5, 40, 50 25 Catalog Number Build-A-Code kV Basic Amps Catalog Number ___ _____ Contact Cooper Bussmann for complete specifications on medium voltage fuses. 86 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com ___ Medium Voltage Fuses Fast-acting Fuses HVA, HVB, HVJ, HVL, HVR, HVT, HVU, HVW & HVX Test Specifications Basic Catalog Numbers HVA, HVB, HVJ, HVL HVR, HVT, HVU, HVW, HVX Load / Opening Time 110% / 4 Hours (min) 135% / 1 Hour (max) 100% / 4 Hours (min) 150% / 1 Hour (max) Features and Benefits * Physical size varies with electrical rating of fuse to prevent over-fusing. * Space saving size. Typical Applications * Medium Voltage Instrument Protection * Medium Voltage Circuit Protection Medium Voltage Fuses Specifications Description: Medium voltage, non-time delay, fast-acting fuses. Dimensions: See Basic Catalog Numbers table. Ratings: Volts: -- 1-10kV (See Basic Catalog Numbers table) Amps: -- 116-10A (See Basic Catalog Numbers table) Fuse blocks: 4528, 4529, 4530 & 2960 Voltage Rating: 1000 to 10,000V Basic Catalog Numbers HVA, HVR HVB, HVT HVJ, HVU HVL, HVX Fuse Block Catalog Number 4528 4529 4530 2960 Fuse Clip Catalog Number 5960 5960 4180 4180 Use #8 screws on blocks 4528 and 4529. Use #10 screws on blocks 4530 and 2960. Basic Catalog Number HVA kV 1 HVB HVJ HVL HVR HVW HVT HVU HVX 2.5 5 10 1 1.2 2.5 5 10 Amp Ratings 1 16, 110, 18, 210, 14, 310, 38, 12, 3 4, 1, 1 12, 2, 3, 4, 6, 10 1 2, 34, 1, 1 12, 2, 3 1 16, 18, 14, 12, 34, 1 12, 2, 4, 6, 10 1 16, 18, 14, 12, 1, 1 12, 2, 3 1 2, 1, 2, 3, 4, 5 1, 2, 3, 4, 5, 8 1 2, 1, 2, 3, 5 1 2, 1, 2, 3, 4, 5 1 2, 1, 3, 5 Maximum S.C. 20kW dc/30kVA ac Dimensions - in (mm) Diameter Length 0.41 (10.4) 3 (76.1) 20kW dc/30kVA ac 20kW dc/30kVA ac 20kW dc/30kVA ac kVA-500 ac only kVA-12,000 ac only kVA-1250 ac only kVA-2500 ac only kVA-5,000 ac only 0.41 0.81 0.81 0.41 0.41 0.41 0.81 0.41 (10.4) (20.6) (20.6) (10.4) (10.4) (10.4) (20.6) (10.4) 4.5 (114.2) 5 (126.9) 10 (254) 3 (76.2) 2.25 (57.1) 4.5 (114.2) 5 (126.9) 10.0 (253.8) Catalog Number Build-A-Code Basic Catalog Number Amps _____ ___ Data Sheet: 6003 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 87 Medium Voltage Fuses EEI-NEMA Type K & T and Type H & N FL: Type H and EEI-NEMA Type K & T Fuses Specifications Description: Medium voltage fuses: Type H (high surge), EEI-NEMA Type K (fast-acting), EEI-NEMA Type T (slow-acting). Ratings: Amps: -- 1-200A (See Catalog Numbers tables) Features and Benefits * Wide range of EEI-NEMA type fuse links for use in open fuse cutouts * Voltage ratings up to 27kV. * Can be coordinated with other overcurrent protective devices for sectionalizing to isolate feeder branches. Typical Applications * Medium Voltage Fused Cutouts High-Surge Type H Fuses High-surge, Type H fuses are manufactured in ratings of 1, 2, 3, 5, and 8A. They have been developed principally for primary fusing of small-sized transformers. Type H links are manufactured in the universal buttonhead design. Type N Fuses Type N fuses conform to previous NEMA standards and have been superseded by Type K and T links. Type N fuses are manufactured in the universal button design in ratings of 5 through 200A for use in NEMA standard dimensioned cutouts rated through 27kV. Catalog Numbers EEI-NEMA and High-Surge Universal Tin Element Fuses for Cutouts -- Rated to 27kV Non-Removable Button-Head For Standard Open or Enclosed Cutouts Catalog Numbers Type H EEI-NEMA (High Type K Surge) (Fast) FL11H1 FL11K1 FL11H2 FL11K2 FL11H3 FL11K3 FL11H5 FL11K5 -- FL11K6 FL11H8 FL11K8 -- FL11K10 -- FL11K12 -- FL11K15 -- FL11K20 -- FL11K25 -- FL11K30 -- FL11K40 -- FL11K50 -- FL11K65 -- FL11K80 -- FL11K100 -- FL11K140 -- FL11K200 EEI-NEMA Type T (Slow) FL11T1 FL11T2 FL11T3 FL11T5 FL11T6 FL11T8 FL11T10 FL11T12 FL11T15 FL11T20 FL11T25 FL11T30 FL11T40 FL11T50 FL11T65 FL11T80 FL11T100 FL11T140 FL11T200 Amps 1 2 3 5 6 8 10 12 15 20 25 30 40 50 65 80 100 140 200 Removable Button-Head For Cutouts Requiring Removable-Button Links Catalog Numbers EEI-NEMA EEI-NEMA Type K Type T (Fast) (Slow) FL3K1 FL3T1 FL3K2 FL3T2 FL3K3 FL3T3 FL3K5 FL3T5 FL3K6 FL3T6 FL3K8 FL3T8 FL3K10 FL3T10 FL3K12 FL3T12 FL3K15 FL3T15 FL3K20 FL3T20 FL3K25 FL3T25 FL3K30 FL3T30 FL3K40 FL3T40 FL3K50 FL3T50 FL3K65 FL3T65 FL3K80 FL3T80 FL3K100 FL3T100 FL3K140 FL3T140 FL3K200 FL3T200 Amps 1 2 3 5 6 8 10 12 15 20 25 30 40 50 65 80 100 140 200 Adapter-type removable-button links with ferrule adapter to convert to double-leader links are available in K and T types. Order by description. EEI-NEMA Type K Universal Silver-Element Fuses for Cutouts -- Rated through 27kV Non-Removable Button-Head For Standard Open or Enclosed Cutouts Catalog Numbers EEI-NEMA Type K Amps FL12K8 8 FL12K10 10 FL12K12 12 FL12K15 15 FL12K25 25 FL12K50 50 88 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com Medium Voltage Fuses BBU Boric Acid Fuses BBU is designed to operate. Its dielectric withstand level corresponds to insulation levels of power class equipment, thus the name "power fuse." Maximum voltage ratings for BBU fuses are: 17kV, 27kV and 38kV. Amps:-- The continuous amp rating of a BBU fuse should equal or exceed the maximum load current where the fuse is applied. They are designed to carry their rated continuous current without exceeding the temperature rise outlined in NEMA and ANSI standards. The BBU is available with continuous current ratings up to 200 amps The current ratings carry an "E" designation as defined by ANSI and NEMA. For example, the current responsive element rated 100E amps or below will melt in 300 seconds at an RMS current within the range of 200 to 240 percent of the continuous current ratings. Above 100E amps, melting takes place in 600 seconds at an RMS current within the range of 220 to 264 percent of the continuous current rating. IR:-- BBU fuses have interrupting capabilities from 10kA to 14kA symmetrical. Features and Benefits * Voltage ratings of up to 38kV coupled with ratings to 200A provide a wide range of circuit protection. * Time-current characteristics allow for easier coordination with downstream devices. * Provides replacement of a variety of existing systems. Typical Applications * Power and Distribution Transformer Protection * Medium Voltage Feeder Circuit Protection * Distribution Transformers * Medium Voltage Metal-enclosed Switchgear * Medium Voltage Pad-mounted Switches For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 89 Medium Voltage Fuses that elongate the arc through a boric acid chamber upon release by the fuse Specifications element to interrupt short circuits within Description: Boric one-half cycle and prevent the arc from acid fuses for power re-striking after a current zero. transformers, feeder BBU End Fittings: BBU end fittings circuits, distribution complete the electrical connection transformers, metalbetween the fuse unit and the fuse enclosed and padmounting. Positioned on the top and mounted switchgear bottom of the fuse, unit end fittings can Construction: be used over again if they remain Principle parts of the undamaged. They are completely replaceable BBU fuse interchangeable with other unit are shown in the manufacturers' equivalent fuse units and cross section views. A mountings. glass epoxy tube Indoor Fittings: The indoor end fittings encloses the assembly are made of high-impact plastic and containing the silver high-conducting copper alloy. The blown fuse element, arcing fuse indicator, located on the top end rod, boric acid cylinder fitting, provides visual indication of a and spring. Using a faulted fuse unit. When engaged into the pure silver element and nichrome wire mounting, the spring-loaded plastic strain element makes the BBU less mounting handle actuates the latch susceptible to failure caused by vibration, mechanism and readily accepts a corona corrosion and fuse element hookstick to install or remove the aging. The components are housed in a assembled fuse unit. fiberglass reinforced resin tube with The bottom indoor fitting is threaded to plated copper contacts. BBU fuses can accept a muffler constructed of a plated directly replace competitive equivalent steel housing, containing copper mesh units. screening, that absorbs and contains the noise and exhaust materials during a fault condition, and prevents contamination of indoor components and mechanisms located within the switchgear. Containment also prevents accidental flash-over from phase-tophase or phase-to-ground by limiting airborne particles and gases. BBU Melt Curve Constructions: The BBU fuse is offered in three constructions to meet specific melt curves for an application. The construction is designated in the Catalog Number suffix as follows; * E (Standard) * K (Fast), and * SE (Slow) Element Vapor Rod withdraws, The curves for the SE construction are Melts elongating arc quenches less inverse and allow for more of a and vaporizing arc at first Boric Acid current zero time-delay at high currents. Consult Cooper Bussmann for application Operation: The BBU fuse uses boric assistance. acid to create the de-ionizing action to Ratings: interrupt the arc. At high temperatures, Volts: -- The maximum voltage rating of boric acid decomposes to produce a the BBU fuse is the highest blast of water vapor and inert boric RMS voltage at which the fuse anhydride. Fault interruption is achieved by an arcing rod and a charged spring Medium Voltage Fuses BBU Boric Acid Fuses for Indoor Use Catalog Numbers* BBU17-3K BBU17-6K BBU17-8K BBU17-10K BBU17-12K BBU17-15K BBU17-20K BBU17-25K BBU17-30K BBU17-40K BBU17-50K BBU17-65K BBU17-80K BBU17-100K BBU17-140K BBU17-200K BBU17-5E BBU17-7E BBU17-10E BBU17-13E BBU17-15E BBU17-20E BBU17-25E BBU17-30E BBU17-40E BBU17-50E BBU17-65E BBU17-80E BBU17-100E BBU17-125E BBU17-150E BBU17-175E BBU17-200E BBU17-15SE BBU17-20SE BBU17-25SE BBU17-30SE BBU17-40SE BBU17-50SE BBU17-65SE BBU17-80SE BBU17-100SE BBU17-125SE BBU17-150SE BBU17-175SE BBU17-200SE Amps 3 6 8 10 12 15 20 25 30 40 50 65 80 100 140 200 5 7 10 13 15 20 25 30 40 50 65 80 100 125 150 175 200 15 20 25 30 40 50 65 80 100 125 150 175 200 Fuse Type K K E E SE SE Voltage kV 17 Max Int. kA Sym 14 17 14 17 14 17 17 14 14 17 14 Catalog Numbers* BBU27-3K BBU27-6K BBU27-8K BBU27-10K BBU27-12K BBU27-15K BBU27-20K BBU27-25K BBU27-30K BBU27-40K BBU27-50K BBU27-65K BBU27-80K BBU27-100K BBU27-140K BBU27-200K BBU27-5E BBU27-7E BBU27-10E BBU27-13E BBU27-15E BBU27-20E BBU27-25E BBU27-30E BBU27-40E BBU27-50E BBU27-65E BBU27-80E BBU27-100E BBU27-125E BBU27-150E BBU27-175E BBU27-200E BBU27-15SE BBU27-20SE BBU27-25SE BBU27-30SE BBU27-40SE BBU27-50SE BBU27-65SE BBU27-80SE BBU27-100SE BBU27-125SE BBU27-150SE BBU27-175SE BBU27-200SE Amps 3 6 8 10 12 15 20 25 30 40 50 65 80 100 140 200 5 7 10 13 15 20 25 30 40 50 65 80 100 125 150 175 200 15 20 25 30 40 50 65 80 100 125 150 175 200 * BBU Melt Curve Constructions: The BBU fuse is offered in three constructions to meet specific melt curves for an application. The construction is designated in the Catalog Number suffix: E (Standard), K (Fast) and SE (Slow). Contact Cooper Bussmann for application details. Fuse Type K Voltage kV 27 Max Int. kA Sym. 12.5 K 27 12.5 E 27 E SE SE 12.5 27 27 12.5 12.5 27 12.5 Catalog Numbers BBU38-3K BBU38-6K BBU38-8K BBU38-10K BBU38-12K BBU38-15K BBU38-20K BBU38-30K BBU38-40K BBU38-50K BBU38-65K BBU38-80K BBU38-100K BBU38-140K BBU38-200K BBU38-5E BBU38-7E BBU38-10E BBU38-13E BBU38-15E BBU38-20E BBU38-25E BBU38-30E BBU38-40E BBU38-50E BBU38-65E BBU38-80E BBU38-100E BBU38-125E BBU38-150E BBU38-175E BBU38-200E BBU38-15SE BBU38-20SE BBU38-25SE BBU38-30SE BBU38-40SE BBU38-50SE BBU38-65SE BBU38-80SE BBU38-100SE BBU38-125SE BBU38-150SE BBU38-175SE BBU38-200SE Amps 3 6 8 10 12 15 20 30 40 50 65 80 100 140 200 5 7 10 13 15 20 25 30 40 50 65 80 100 125 150 175 200 15 20 25 30 40 50 65 80 100 125 150 175 200 Fuse Type K K E Voltage kV 38 38 38 E SE SE 90 38 38 Note: Muffler can be ordered separately. Order Catalog number BBU-MFLR. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 10 38 End Fitting Detail Data Sheet: 1123 10 10 Application Notes Low currents, usually referred to as overload currents, must be considered as BBU fuses have a rather low thermal capacity. They cannot carry overloads of the same magnitude/duration as motors and transformers of equal continuous currents. For this reason, the BBU fuse must be sized with the full load current in mind so the fuse does not open on otherwise acceptable overloads and inrush conditions. Coordination should be considered to help determine what type of fuse is applied. The BBU fuse interrupts at a natural current zero in the current wave and allows a minimum of a half-cycle of fault current to flow before the fault is cleared. The time-current characteristics associated with a BBU fuse has a rather gradual slope making it easier to coordinate with downstream equipment. In addition, the BBU is ideal for higher voltage (up to 38kV) and high current applications (up to 200A). It is important to examine the minimum melting and total clearing time-current characteristics of this fuse. Max Int. kA Sym. 10 10 10 Medium Voltage Fuses Fuseclips for Medium & High Voltage Fuses Recommended Fuseclips for Medium Voltage Fuses Catalog Numbers A3354710 A3354730 A3354745 Fuse Diameter in (mm) 2 (50.8) 3 (76) 1.77 (45) A 3.749 4.139 3.50 B 1.979 2.449 2.50 Clip Dimensions (in) C D E 2.009 1.189 4.539 3.009 1.189 5.639 1.77 1.19 4.50 F 1.509 1.509 1.50 G 0.399 0.399 0.38 C A G Fuseclips are for single barrel applications only. Are not sold in pairs. F E D B 270303 DIN Fuseclip A Medium Voltage Fuses 1A0065 3" Diameter Clip 0.99" 25.0mm 4.06" 103mm A 0.43" 10.8mm 9078A67G04 3" Diameter Clip 2 Cup assemblies per package. Dimensions shown are for reference only. For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 91 92 High Speed Fuses Section Contents Page General Applications . . . . . . . . . . . . . . . . . . . . . . . . 94-95 North American fuses & accessories . . . . . . . . . . . .94-113 DFJ - High speed Class J fuse . . . . . . . . . . . . . . . . . . .97 Square Body fuses & accessories . . . . . . . . . . . . 114-176 BS 88 fuses & accessories . . . . . . . . . . . . . . . . . .177-185 Ferrule fuses & accessories. . . . . . . . . . . . . . . . . .186-206 High Speed Fuses 93 High Speed Fuses General Applications Rated Voltage Power Factor The AC voltage rating of Cooper Bussmann(R) fuses is given in volts rms. Fuses tested to IEC are tested at 5% above their rated voltage. British Style BS 88 fuses are tested at 10% above its rated voltage. UL recognition tests are performed at the rated voltage. For other power factor values, the total clearing integral can be calculated as a multiple of the clearing integrals, the correction factor K and the correction factor X. 1.0 Arc Voltage 0.7 Rated Current Rated current is given in amps rms. Cooper Bussmann fuses can continuously carry the rated current. X 0.9 0.8 Melting Characteristic The melting 10 6 4 characteristic 2 shows the virtual 10 melting time in 6 4 seconds as a 2 function of the 10 6 prospective current 4 in amperes rms. 2 10 The fuses are 6 4 specially 2 constructed for 10 6 short-circuit 4 protection against 2 high level fault 10 6 currents. Loading 4 2 and operation of 10 the fuse in 6 4 the non2 continuous/dashed 10 6 section of the melt 4 curve must be 2 10 avoided. The curve 2 4 6 8 10 2 4 6 8 10 10 Prospective Current In Amperes RMS can also be read as the real melting time as a function of the RMS value of the pre-arc current. 4 3 1 0 -1 -2 -3 -4 1 2 Clearing Integrals 1.5 The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1.0 3 K 0.2 0.3 0.4 103 9 8 7 6 5 4 Eg 200 300 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, K p , is given as a function of the RMS load current, Ib , in % of the rated current . 0.5 COS 1.4 1.2 UL 3 Power Losses 400 500 600 660 1.0 Kp 0.8 0.6 0.5 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 80 90 100% Cut-Off Current A fuse operation relating to short-circuits only. When a fuse operates in its current-limiting range, it will clear a shortcircuit in less than 12 cycle. Also, it will limit the instantaneous 0.5 0.4 105 0.3 0.2 Eg 100 200 300 400 500 600 660 Peak Let-Through Current Virtual Pre-Arcing Time In Seconds 2 0.1 This curve gives the peak arc voltage, U L , which may appear across the fuse during its operation as a function of the applied working voltage, E g , (rms) at a power factor of 15%. 104 103 A B 2 10 2 102 103 104 Prospective Current in Amps RMS 105 106 peak let-through current to a value substantially less than that obtainable in the same circuit if that fuse were replaced 94 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses General Applications with a solid conductor of equal impedance. A asymmetrical current B symmetrical current Parallel Connection When fuses are connected in parallel it is recommended that the applied voltage does not exceed 0.9 UN (the rated voltage of the fuse). This is due to the fact that the energy released within the fuses may be unevenly shared between the parallel connected barrels. When fuses are connected in parallel, one must take into account that the current sharing is not necessarily equal. And it must be checked, that the maximum load current is not exceeded. Fuses in series may not equally divide the applied voltage. It is recommended that series connected fuses should only be operated at fault currents that yield melting times less than 10 ms and a recovery voltage per fuse of less than or equal to 0.9 UN (the rated voltage of the fuse). Mounting Guidance The recommendations below have to be followed when mounting a Cooper Bussmann fuse with end plate threaded holes. 1. Screw in studs: 5 N*m Max, 3 N*m Min 2. Attachment of the fuse to bussbar by means of nut and washer: Thread Configuration 5 16" - 18, M8 3 8" - 16, M10 3 8" - 24 1 2" - 13, M12 1 2" - 20 *1 N*m = 0.7375 lb-ft Torque (N*m)* Max Min 25 20 45 40 45 40 65 50 65 50 Overloads The design of Cooper Bussmann(R) fuses is such that they can be operated under rather severe operating conditions imposed by overloads (any load current in excess of the maximum permissible load current). In applications, there will be a maximum overload current, Imax, which can be imposed on the fuse with a corresponding duration and frequency of occurrence. Time durations fall into two categories: 1. Overloads longer than one second 2. Overloads less than one second termed "impulse" loads. The following table gives general application guidelines which, in the expression Imax < (% factor) x It. It is the Frequency of Occurrence Less than once per month Less than twice per week Overloads (> 1 sec) Imax < 80% x It Imax < 70% x It Impulse Loads (< 1 sec) Imax < 70% x It Imax < 60% x It Several times per day Imax < 60% x It -- When impulse loads are an intrinsic/normal parameter of the load current either as single pulse or in trains of pulses or when their level is higher than the melting current at 0.01 seconds (per time-current curve), contact Cooper Bussmann for application assistance. In addition to the parameters set forth in the preceding table, the RMS value of the load current as calculated for any period of 10 minutes or more should not exceed the maximum permissible load current. Furthermore, it is important that a fuse should not be applied in the non-continuous/dashed portion of the associated time-current curve. Any time-current combination point which falls in the non-continuous/dashed portion of the time-current curve is beyond the capability of the fuse to operate properly. DC Operation Depending upon the short-circuit time constant and the magnitude of the prospective short-circuit current, the dc voltage at which a fuse can be applied may be less than its ac rating. Long time constants require a lower dc voltage. Conversely, however, higher available prospective shortcircuit currents result in faster fuse openings and thus permit a fuse to be operated at a higher DC voltage. Consult Cooper Bussmann for additional information and application assistance when fuses have to operate under DC conditions. 1.0 Load Current Versus 0.8 Reduction Factor 0.9 Conductor Cross Section 0 . 5 0 . 6 0 . 7 0.8 0.9 (IEC cross section) 1.0 Reduction of permissible load current when the conductor cross section is less than that given in IEC Publication 269-1 & 4 valid for Cooper Bussmann high speed fuses. Application Assistance If you have application problems or need a fuse outside our standard program, please contact the nearest Cooper Bussmann representative. Phone numbers are shown on the back cover. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 95 High Speed Fuses Series Connection melting current corresponding to the time "t" of the overload duration as read from the time-current curve of the fuse. The guidelines in the table below determine the acceptability of the selected fuses for a given Imax. High Speed Fuses North American Fuses Introduction North American Contents Catalog Number DFJ FWA FWA FWX FWH KAC KBC FWP FWJ Volts 600 130 150 250 500 600 600 700 1000 General Information Amp Range 1-600 1000-4000 70-1000 35-2500 35-1600 1-1000 35-800 5-1200 35-2000 Accessories Fuse Bases 113 North American Fuse Ranges Amps 1000-4000 70-1000 35-2500 35-1600 1-1000 5-1200 40-600 35-2000 96 Page 97 98-99 100-101 102-103 104-105 106 107 108-110 111-112 Volts 130 150 250 500 600 700 800 1000 AC X X X X X X -- X DC X X X X -- X X -- Cooper Bussmann offers a complete range of North American blade and flush-end style fuses and accessories. Their design and construction were optimized to provide: * Low energy let-through (I2t) * Low watts loss * Superior cycling capability * Low arc voltage * Excellent DC performance North American style fuses provide an excellent solution for medium power applications. While there are currently no published standards for these fuses, the industry has standardized on mounting centers that accept Cooper Bussmann fuses. Voltage Rating All Cooper Bussmann(R) North American style fuses are tested at their rated voltage. Cooper Bussmann should be consulted for applications exceeding those values. Accessories External and internal open fuse indication is available for selected portions of the North American line. Fuse blocks are available for most applications. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Drive Fuse High Speed Fuses Time-Current Characteristic Curves--Average Melt Specifications Description: High speed, current-limiting fuse. The Cooper Bussmann(R) Drive Fuse will provide maximum protection for AC and DC drives and controllers and meet NEC(R) branch circuit protection requirements. The Drive Fuse has the lowest I2t of any branch circuit fuse to protect power semiconductor devices that utilize diodes, GTOs, SCRs and SSRs. Dimensions: See page 15 for Class J dimensions. Construction: Melamine tube with silver fuse element. Ratings: Volts -- 600Vac (or less), 450Vdc (or less) Amps -- 1-600A IR -- 200kA RMS Sym., 100kA DC Agency Information: CE, Std. 248-8, Class J, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787. Current Limitation Curves High Speed Fuses DFJ Class J Features and Benefits * Easily coordinated with existing and new variable speed drives and electric controllers. * Standard Class J dimensions allowing the use of readily available fuse blocks, holders, and switches. * Allows the lowest let-thru energy of any branch circuit overcurrent protective device. Typical Applications * Protection of ac & dc drives * Equipment using power semi-conductor devices Catalog Numbers (Amps) DFJ-1 DFJ-2 DFJ-3 DFJ-4 DFJ-5 DFJ-6 DFJ-8 DFJ-10 DFJ-12 DFJ-15 DFJ-20 DFJ-25 DFJ-30 DFJ-35 DFJ-40 DFJ-45 DFJ-50 DFJ-60 DFJ-70 DFJ-80 DFJ-90 DFJ-100 DFJ-110 DFJ-125 DFJ-150 DFJ-175 DFJ-200 DFJ-225 DFJ-250 DFJ-300 DFJ-350 DFJ-400 DFJ-450 DFJ-500 DFJ-600 Data Sheet: 1048 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 97 High Speed Fuses North American -- FWA 130V: 1000-4000A FWA Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: North American style flush-end high speed fuses. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 130Vac Amps: -- 1000-4000A IR: -- 200kA RMS Sym. -- 50kA @130Vdc Agency Information: CE, UL Recognized on 1000-2000A fuses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1.5 K 1.0 1mm 0.0394 / 1 200 100 Eg 50 0.6 0.5 0.4 0.3 0.2 Ib 0.1 B 2.0 3.0 3.5 0.3 0.2 Catalog Numbers FWA-1000AH FWA-1200AH FWA-1500AH FWA-2000AH FWA-2500AH FWA-3000AH FWA-4000AH Eg 0.15 26 65 104 130 C 1.0 1.5 1.5 D -- -- 1.5 Thread Depth Tapped 38"-24 x 12" Tapped 12"-20 x 12" Tapped 12"-20 x 12" 25.4mm ig. 2 4000A 1.875 1.875 70 Electrical Characteristics I2t (A2 Sec) Rated Current Clearing RMS-Amps Pre-arc at 130V 1000 170000 460000 1200 270000 730000 1500 520000 1400000 2000 860000 2400000 2500 1500000 4100000 3000 2100000 5700000 4000 3400000 9200000 * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters D C B C Data Sheet: 720001 98 60 * Watts loss provided at rated current. * See accessories on page 113. Fig. 1 1 2 150 80 90 100% Catalog Numbers 0.5 ig. 1 1000-3000A B 100 1.0 Kp 0.8 30 40 50 Dimensions (in) Catalog Number FWA-1000AH-2000AH FWA-2500AH-3000AH FWA-4000AH 300 Power Losses Electrical Characteristics Total Clearing UL For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Watts Loss 60 70 78 108 130 150 257 High Speed Fuses North American -- FWA 130V: 1000-4000A FWA 1000-4000A: 130V Time-Current Curve 104 6 4 2 103 6 4 FWA-1000AH FWA-1200AH FWA-1500AH FWA-2000AH FWA-2500AH FWA-3000AH FWA-4000AH 2 102 6 4 High Speed Fuses Virtual Pre-Arcing Time In Seconds 2 101 6 4 2 10 0 6 4 2 10-1 6 4 2 10-2 6 4 2 10-3 6 4 2 10-4 2 103 4 6 8 2 4 104 Prospective Current In Amps RMS 6 8 105 Peak Let-Through Curve 2 105 6 ea Let-Through Current 4 2 WA-4000A WA-3000A 104 WA-2500A WA-2000A WA-1500A 6 WA-1200A WA-1000A 4 2 103 103 2 4 6 104 2 4 6 105 rospective Short-Circuit Current Symmetrical RMS 2 4 6 Data Sheet: 35785301 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 99 High Speed Fuses North American -- FWA 150V: 70-1000A FWA Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: North American style stud-mount fuses. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 150Vac/dc Amps: -- 70-1000A IR: -- 100kA Sym. (70-400A) -- 200kA Sym. (450-1000A) -- 20kA @150Vdc (70-800A) -- 100kA @ 80Vdc (70-400A) Agency Information: CE, UL Recognized K 1.0 0.3 0.2 0.15 22 1) 2) Eg 70 102 150 1) 500-1000A Range 2) 70-400A Range Dimensions (in) Fig. 1: 70-400A 2.656 2.188 Catalog Number FWA-70B FWA-80B FWA-100B FWA-125B FWA-150B FWA-200B FWA-250B FWA-300B FWA-350B FWA-400B FWA-500A FWA-600A FWA-700A FWA-800A FWA-1000A 0.125 1.000 0.438 Rated Current RMS-Amps 70 80 100 125 150 200 250 300 350 400 500 600 700 800 1000 3.500 2.438 1.250 0.250 150 0.6 0.5 0.4 0.3 0.2 Ib 0.1 60 Electrical Characteristics I2t (A2 Sec) Clearing Pre-arc at 150V 470 4000 670 6000 1200 12000 1870 18000 2700 26000 4780 45000 7470 70000 10760 100000 15700 140000 20300 180000 39000 120000 46000 140000 75000 220000 92000 280000 170000 510000 70 * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 1.500 0.406 Data Sheet: 720002 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 80 90 100% Watts Loss 6.9 7.7 9.0 11.2 13.5 17.6 22.5 27.0 30.6 35.2 35.0 47.0 49.0 58.0 60.0 Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability 1mm = 0.0394" / 1" = 25.4mm 100 100 * * * * Fig. 2: 500-1000A 1.000 50 1.0 Kp 0.8 * Watts loss provided at rated current. * See accessories on page 113. 1.936 1.156 0.750 0.312 100 30 40 50 Catalog Numbers 0.5 200 Eg Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. 1.5 The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 300 Power Losses Electrical Characteristics Total Clearing I2t UL High Speed Fuses North American -- FWA 150V: 70-1000A FWA 70-1000A: 150V Time-Current Curve 104 6 4 2 103 6 4 FWA-500A FWA-600A FWA-700A FWA-800A FWA-1000A 2 102 6 4 10 High Speed Fuses Virtual Pre-Arcing Time In Seconds 2 1 6 4 2 100 6 4 2 10-1 6 4 FWA-70A FWA-80A FWA-100A FWA-125A FWA-150A 2 10-2 6 4 2 -3 10 FWA-200A FWA-250A FWA-300A FWA-350A FWA-400A 6 4 2 10-4 2 102 4 6 8 2 4 6 103 Prospective Current In Amps RMS 8 104 Peak Let-Through Curve 106 6 4 WA-400A WA-350A 2 WA-300A WA-250A 104 WA-200A ea Let-Through Current WA-150A 6 WA-100A 4 2 3 10 6 WA-80A 4 WA-70A 2 102 2 102 4 6 2 103 4 6 2 104 4 2 6 105 rospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785310 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 101 High Speed Fuses North American -- FWX 250V: 35-2500A FWX Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: North American style stud-mount and flush-end fuses. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 250Vac/dc Amps: -- 35-2500A IR: -- 200kA RMS Sym. Agency Information: CE, UL Recognized & CSA Component Acceptance on 35-800A fuses (20kA IR @250Vdc). Power Losses Watts loss at rated current is given in the electrical char acteristics. The curve allows the calculation of the power losses at load currents lower than the rated current . The correction factor, K p , is given as a function of the RMS load current, Ib , in % of the rated current . 1.5 Electrical Characteristics K 1.0 Total Clearing I t 2 The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 0.5 1) Catalog Numbers 2) 0.3 0.2 Eg 0.15 75 125 200 250 Dimensions (in) Amp Range Fig. A B C 35-60 1 3.19 0.81 1.59 70-200 1 3.13 1.22 1.59 225-600 1 3.84 1.50 1.59 700-800 1 3.84 2.00 1.59 1000-1200 2 2.59 3.00 1.50 1500-2500 3 2.59 3.50 1.50 1mm = 0.0394" / 1" = 25.4mm Fig. 1: 35-800A D 2.59 2.44 2.94 3.03 -- 1.50 300 1) 35-800A Range 2) 1000-2500A Range E 2.25 2.19 2.25 2.28 -- -- F 0.34 0.34 0.41 0.41 -- -- G 0.63 1.00 1.00 1.50 -- -- Fig. 2: 1000-1200A H 0.13 0.19 0.25 0.25 -- -- J 0.52 0.47 0.75 0.78 -- -- Tapped Thread Depth -- -- -- -- 3 8"-24 x 12" 3 8"--24 x 12" Fig. 3: 1500-2500A J A A A D E C D Catalog Number FWX-35A FWX-40A FWX-45A FWX-50A FWX-60A FWX-70A FWX-80A FWX-90A FWX-100A FWX-125A FWX-150A FWX-175A FWX-200A FWX-225A FWX-250A FWX-275A FWX-300A FWX-350A FWX-400A FWX-450A FWX-500A FWX-600A FWX-700A FWX-800A FWX-1000AH FWX-1200AH FWX-1500AH FWX-1600AH FWX-2000AH FWX-2500AH Rated Current RMS-Amps 35 40 45 50 60 70 80 90 100 125 150 175 200 225 250 275 300 350 400 450 500 600 700 800 1000 1200 1500 1600 2000 2500 B F G C C UL 103 800 600 500 400 102 2) Eg 200 50 100 150 200 250 1) 35-800A Range 2) 1000-2500A Range 1.0 Kp 0.8 0.6 0.5 0.4 0.3 0.2 Ib 0.1 60 Electrical Characteristics I2t (A2 Sec) Clearing Pre-arc at 250V 50 230 60 310 80 390 100 520 140 740 330 1400 430 1850 570 2450 740 3150 1130 4850 1620 6950 2170 9300 2790 12000 3210 14700 3960 18100 4720 21600 6000 27300 10600 48600 14500 66100 22100 101000 28000 128000 41100 188000 48800 190000 59000 230000 44000 360000 92000 750000 120000 880000 160000 1200000 320000 2300000 670000 4700000 70 80 90 100% Watts Loss 4.2 5.2 5.7 6.0 8.1 7.2 8.1 9.0 10.0 12.5 15.7 18.5 22 24 27 31 32 39 44 49 54 62 72 84 100 103 140 140 151 163 * See accessories on page 113. Features and Benefits * Excellent DC performance * Low arc voltage and low energy let-through (I2t) * Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters H B 1) 300 30 40 50 * Watts loss provided at rated current. B 1.4 1.2 Data Sheet: 720005 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses North American -- FWX 250V: 35-2500A FWX 35-800A: 250V FWX 1000-2500A(H): 250V Time-Current Curve Time-Current Curve 104 6 4 104 2 103 3 10 FWX-200A FWX-350A FXW-400A FWX-500A FWX-600A FWX-800A 6 4 2 FWX-1000AH FWX-1200AH FWX-1500AH FWX-1600AH FWX-2000AH FWX-2500AH 2 10 101 6 4 2 Virtual Pre-Arcing Time In Seconds 100 FWX-35A FWX-40A FWX-60A FWX-70A FWX-100A FWX-150A 10-1 10-2 10-3 10-4 102 2 103 Prospective Current In Amps RMS 104 1 High Speed Fuses Virtual Pre-arcing Time In Seconds 102 10 6 4 2 100 6 4 2 10-1 6 4 2 10-2 6 4 Peak Let-Through Curve 2 105 10-3 6 4 B 2 FWX-800A FWX-600A FWX-400A FWX-300A FWX-200A 10-4 2 103 4 6 8 2 4 6 104 Prospective Current In Amps RMS 8 105 Peak Let-Through Current 104 Peak Let-Through Curve 105 6 WX-2500A 4 103 A ea Let-Through Current FWX-150A FWX-100A FWX-70A FWX-60A FWX-45A FWX-35A WX-2000A WX-1600A WX-1500A WX-1200A 2 WX-1000A 104 6 4 102 102 103 104 105 Prospective Short-Circuit Current Symmetrical RMS 2 103 103 2 4 6 104 2 4 6 105 2 4 6 rospective Short-Circuit Current Symmetrical RMS Data Sheet: 359 Data Sheet: 35785299 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 103 High Speed Fuses North American -- FWH 500V: 35-1600A FWH Arc Voltage 2.0 Specifications Description: North American style stud-mount fuses. Dimensions: See Dimensions illustration. Ratings: Volts: -- 500Vac/dc Amps: -- 35-1600A IR: -- 200kA Sym. -- 50kA @ 500Vdc Agency Information: CE, UL Recognition & CSA Component Acceptance on 35-800A only (50kA IR@500Vdc). UL Recognition on 35-1200A only, CSA Component Acceptance: 35-1600A. This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. 1.6 Electrical Characteristics Total Clearing I2t 1.5 The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1.0 K 0.5 0.3 0.2 2) Fig. 1 1 1 1 1 1 1 2 250 400 500 1) 35-800A Range 2) 1000-1600A Range Dimensions (in) Amp Range 35-60 70-100 125-200 225-400 450-600 700-800 1000-1200 1400-1600 Eg 0.15 100 A B 3.188 0.813 3.625 0.947 3.625 1.156 4.340 1.500 4.340 2.000 6.340 2.500 6.969 3.000 See Drawing C 1.593 1.736 1.836 2.090 2.090 2.090 3.219 D 2.541 2.853 2.892 3.440 3.530 4.970 5.465 E 2.193 2.807 2.768 2.750 2.780 3.440 4.475 F 0.344 0.352 0.344 0.410 0.410 0.530 0.625 G 0.719 0.750 1.000 1.000 1.500 2.000 2.375 H 0.125 0.125 0.188 0.250 0.250 0.380 0.438 1mm = 0.0394" / 1" = 25.4mm Fig. 1: 35-1200A A D E C H G F B J Fig. 2: 1400-1600A 10.219 0.125 0.5 3.219 0.625 3.5 104 0.75 4.25 103 800 600 2) 500 Catalog Numbers FWH-35B FWH-40B FWH-45B FWH-50B FWH-60B FWH-70B FWH-80B FWH-90B FWH-100B FWH-125B FWH-150B FWH-175B FWH-200B FWH-225A FWH-250A FWH-275A FWH-300A FWH-325A FWH-350A FWH-400A FWH-450A FWH-500A FWH-600A FWH-700A FWH-800A FWH-1000A FWH-1200A FWH-1400A FWH-1600A Eg 200 300 400 500 1) 35-200 & 1000-1600A Range 2) 225-800A Range Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Rated Current RMS-Amps 35 40 45 50 60 70 80 90 100 125 150 175 200 225 250 275 300 325 350 400 450 500 600 700 800 1000 1200 1400 1600 1) 400 300 100 1.0 Kp 0.8 0.6 0.5 0.4 0.3 0.2 Ib 0.1 30 40 50 60 Electrical Characteristics I2t (A2 Sec) Clearing Pre-arc at 500V 34 150 76 320 105 450 135 670 210 900 210 900 305 1400 360 1600 475 2000 800 3500 1100 4600 1450 6200 1900 8500 4600 23300 6300 32200 7900 40300 9800 49800 13700 63800 14500 72900 19200 96700 24700 127000 29200 149000 41300 206000 55000 298000 76200 409000 92000 450000 122000 600000 200000 1000000 290000 1400000 * Watts loss provided at rated current. 1.625 1.750 6.219 8.969 J 0.518 0.375 0.406 0.750 0.780 1.300 1.120 1.2 Power Losses Catalog Numbers 1) UL 70 80 90 100% Watts Loss 8 7.5 7.5 7.5 9.9 10.6 12.7 15 17 25 30 35 40 39 41 46 51 53 58 65 74 84 108 120 129 145 180 210 230 * See accessories on page 113. Features and Benefits * Excellent DC performance * Low arc voltage and low energy let-through (I2t) * Superior cycling capability * * * * Data Sheet: 720007 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters High Speed Fuses North American -- FWH 500V: 35-1600A FWH 35-200A(B) & 900-1600A(A): 500V Time-Current Curve 10 FWH 250-800A: 500V Time-Current Curve 103 4 6 4 2 103 6 4 102 FWH-300A FWH-400A FWH-500A FWH-600A FWH-800A 2 102 6 4 101 Virtual Pre-Arcing Time In Seconds 101 6 4 2 100 6 4 FWH-80B FWH-90B FWH-100B FWH-125B FWH-150B FWH-175B FWH-200B FWH-35B FWH-40B FWH-45B FWH-50B FWH-60B FWH-70B 2 10-1 6 4 2 10-2 6 4 High Speed Fuses FWH-900A FWH-1000A FWH-1200A FWH-1400A FWH-1600A 2 100 10-1 10-2 2 10-3 6 4 10-3 2 10-4 2 4 6 8 102 2 4 6 8 2 103 Prospective Current In Amps RMS 4 6 8 104 10-4 102 Peak Let-Through Curve 103 104 Prospective Current In Amps RMS 105 Peak Let-Through Curve 105 105 B W -1600A W -1400A 6 W -1200A W -1000A 4 2 104 ea Let-Through Current ea Let-Through Current 104 6 4 2 103 W W W W W W -800A -600A -500A -400A -300A -250A 103 W -200B 6 W -150B W -125B 4 A W -100B W -80B W -60B W -50B 2 W -40B W -35B 102 102 102 2 4 6 103 2 4 6 104 2 4 6 105 2 102 103 104 rospective Short-Circuit Current Symmetrical RMS 105 rospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785304 Data Sheet: 360 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 105 High Speed Fuses North American -- KAC 600V: 1-1000A KAC Catalog Numbers (Amps) KAC-1 KAC-2 KAC-3 KAC-4 KAC-5 KAC-6 KAC-7 KAC-8 KAC-9 KAC-10 KAC-12 KAC-15 KAC-17.5 KAC-20 Specifications Description: North American style stud-mount fuses. These 600V fuses are supplied as replacements only. For new installations, Cooper Bussmann recommends the 700V FWP Series fuse. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 600Vac Amps: -- 1-1000A IR: -- 200kA RMS Sym. Agency Information: CE, UL Recognition on 1-600A only. KAC-25 KAC-30 KAC-35 KAC-40 KAC-45 KAC-50 KAC-60 KAC-70 KAC-80 KAC-90 KAC-100 KAC-110 KAC-125 KAC-150 KAC-175 KAC-200 KAC-225 KAC-250 KAC-300 KAC-350 KAC-400 KAC-450 KAC-500 KAC-600 KAC-700 KAC-800 KAC-1000 * See accessories on page 113. Features and Benefits * Low arc voltage and low energy let-through (I2t) * Low watts loss * Superior cycling capability Typical Applications * Power converters/rectifiers * Reduced voltage starters Dimensions (in) Amp Range 1-30A 35-60A 70-100A 110-200A 225-400A 450-800A 1000A Fig. 1 2 2 2 2 1 1 A 2.875 4.375 5.000 5.140 6.182 6.250 7.250 B1 2.500 - - - - 4.750 4.750 B2 - 3.750 4.063 4.390 4.815 - - B3 - 3.500 3.656 3.766 4.565 - - C 1.875 2.750 2.750 2.906 3.000 3.063 3.063 D 0.406 0.625 0.750 1.000 1.625 2.000 2.750 E - 0.343 0.406 0.406 0.562 - - F 0.563 0.813 1.000 1.500 2.000 2.500 3.500 G 0.063 0.094 0.125 0.188 0.250 0.250 0.375 H 0.257 0.468 0.609 0.718 0.687 0.563 0.563 1mm = 0.0394 / 1 = 25.4mm ig. 1 1-30 450-1000A A B1 C G D F H ig. 2 35-400A A B2 B3 C D G E F H Data Sheet: 720009 106 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses North American -- KBC 600V: 35-800A KBC Catalog Numbers (Amps) KBC-100 KBC-110 KBC-125 KBC-150 KBC-175 KBC-200 KBC-225 KBC-250 KBC-300 KBC-350 KBC-400 KBC-450 KBC-500 KBC-600 KBC-800 * See accessories on page 113. Features and Benefits * Low arc voltage and low energy let-through (I2t) * Low watts loss * Superior cycling capability Typical Applications * Power converters/rectifiers * Reduced voltage starters High Speed Fuses Specifications Description: North American style stud-mount and flush-end fuses. These 600V fuses are supplied as replacements only. For new installations, Cooper Bussmann recommends the 700V FWP Series fuse. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 600Vac Amps: -- 35-800A IR: -- 200kA RMS Sym. Agency Information: CE, UL Recognition on 35-600A only. KBC-35 KBC-40 KBC-45 KBC-50 KBC-60 KBC-70 KBC-80 KBC-90 Dimensions (in) Amp Range 35-60A 70-100A 110-200A 225-400A 450-600A 800A Fig. 1 2 1 1 1 3 A B C 4.375 3.750 3.500 See Drawing 4.406 3.719 3.594 5.125 4.188 3.563 5.125 4.389 3.687 See Drawing D E F G H I 2.750 0.343 0.625 0.813 0.094 0.468 2.906 0.312 0.875 1.219 0.187 0.375 2.906 0.406 1.000 1.500 0.250 0.719 2.875 0.406 1.500 2.000 0.250 0.757 1mm = 0.0394" / 1" = 25.4mm ig. 1 35-60 and 110-600A A B C D E H F G I 0.312 0.750 1.000 0.125 4.406 3.656 2.906 ig. 2 70-100A ig. 3 800A 4.000 3.750 /*" - 24 /TM" 0.750 2.500 2.859 0.750 Data Sheet: 720010 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 107 High Speed Fuses North American -- FWP 700V: 5-1200A FWP Specifications Description: North American style stud-mount fuses. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 700Vac/dc Amps: -- 5-1200A IR: -- 200kA RMS Sym. -- 50kA @700Vdc Agency Information: CE, UL Recognition & CSA Component Acceptance on 5-800A The total clearing I t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). K 1.0 2) C 1.855 2.750 2.594 2.840 2.840 2.840 2.844 Catalog Numbers 0.5 1) 0.3 0.2 3) Eg 0.15 316 D 2.477 3.708 3.625 4.190 4.280 5.720 5.562 460 E 2.477 3.312 3.563 3.500 3.530 4.190 5.062 604 700 F 0.250 0.344 0.344 0.410 0.410 0.530 0.625 G 0.405 0.725 0.750 1.000 1.500 2.000 1.500 H 0.063 0.125 0.125 0.250 0.250 0.380 0.250 I 0.250 0.542 0.375 0.750 0.780 1.300 0.875 1mm = 0.0394" / 1" = 25.4mm ig. 1 5-800A ig. 2 900-1000A ig. 3 1200A 3.500 1.375 0.125 J 0.500 5.966 7.594 A D E C 9.590 6.840 3.844 0.625 1.031 2.750 0.5 3.500 H B 0.750 4.250 Catalog Numbers FWP-5B FWP-10B FWP-15B FWP-20B FWP-25B FWP-30B FWP-35B FWP-40B FWP-50B FWP-60B FWP-70B FWP-80B FWP-90B FWP-100B FWP-125A FWP-150A FWP-175A FWP-200A FWP-225A FWP-250A FWP-300A FWP-350A FWP-400A FWP-450A FWP-500A FWP-600A FWP-700A FWP-800A FWP-900A FWP-1000A FWP-1200A Rated Current RMS-Amps 5 10 15 20 25 30 35 40 50 60 70 80 90 100 125 150 175 200 225 250 300 350 400 450 500 600 700 800 900 1000 1200 6 5 Eg 300 400 500 600 700 1) 125-600A Range 2) 35-100 & 700-1200A Range 1.0 Kp 0.8 0.6 0.5 0.4 0.3 0.2 Ib 30 40 50 60 Electrical Characteristics I2t (A2 Sec) Clearing Pre-arc at 700V 1.6 10 3.6 20 10 75 26 180 44 340 58 450 34 160 76 320 135 600 210 950 305 2000 360 2400 415 2700 540 3500 1800 7300 2900 11700 4200 16700 5500 22000 7700 31300 10500 42500 17600 71200 23700 95600 31000 125000 36400 137000 45200 170000 66700 250000 54000 300000 78000 450000 91500 530000 120000 600000 195000 1100000 Features and Benefits * Excellent DC performance * Low arc voltage and low energy let-through (I2t) * Superior cycling capability Data Sheet: 720012 108 2) 8 70 80 90 100% Watts Loss 1.5 4 5.5 6 7 9 12 12 12 15.5 18 21 25 27 28 32 35 43 45 48 58 65 78 94 107 122 125 140 150 170 190 * Watts loss provided at rated current. * See accessories on page 113. 1.625 1.750 0.625 G 3.844 10.844 5.154 F 1) 0.1 Dimensions (in) A B 2.870 0.563 4.375 0.813 4.406 0.947 5.090 1.500 5.090 2.000 7.090 2.500 6.630 2.000 See Drawing See Drawing UL 3 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. 1) 35-100A Range 2) 125-600A Range 3) 700-1200A Range Amp Range Fig. 5-30 1 35-60 1 70-100 1 125-200 1 225-400 1 450-600 1 700-800 1 900-1000 2 1200 3 1.6 1.4 1.2 103 4 1.5 2 2 This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Power Losses Electrical Characteristics Total Clearing I2t Arc Voltage * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses North American -- FWP 700V: 5-1200A FWP 5-30A(B): 700V FWP 35-100A(B) & 700-1200A(A): 700V Time-Current Curve Time-Current Curve 104 6 4 104 6 4 2 2 103 103 6 4 6 4 2 2 6 4 6 4 2 Virtual Pre-Arcing Time In Seconds 6 4 2 100 6 4 FWP-5B FWP-10B FWP-15B FWP-20B FWP-25B FWP-30B 2 10-1 6 4 101 6 4 FWP-35B FWP-40B FWP-50B FWP-60B FWP-70B FWP-80B FWP-90B FWP-100B 2 100 6 4 High Speed Fuses Virtual Pre-Arcing Time In Seconds 2 101 2 10-1 6 4 2 2 10-2 10-2 6 4 6 4 2 2 10-3 10-3 6 4 6 4 2 2 10-4 FWP-700A FWP-800A FWP-900A FWP-1000A FWP-1200A 102 102 10-4 2 4 6 8 2 101 4 6 8 2 102 4 6 8 103 2 4 6 8 2 4 6 8 2 103 Prospective Current In Amps RMS 102 Prospective Current In Amps RMS Peak Let-Through Curve 4 6 8 104 Peak Let-Through Curve 106 104 W -1200A 6 W -1000A 6 W -800A 4 4 W -700A 2 ea Let-Through Current 10 W -30B W -25B 3 2 104 6 ea Let-Through Current 4 2 10 W W W W 2 -20B -15B -10B - 5B 6 4 6 4 2 103 2 6 W -100B 4 101 101 2 4 6 102 2 4 6 103 2 4 6 104 2 4 6 105 W -70B 2 W -60B rospective Short-Circuit Current W -50B 2 W -40B W -35B 102 2 4 6 102 2 4 6 103 2 104 4 6 2 105 rospective Short-Circuit Current Data Sheet: 35785316 Data Sheet: 35785308 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 109 High Speed Fuses North American -- FWP 700V: 5-1200A FWP 150-600A: 700V Time-Current Curve 103 102 FWP-150A FWP-200A FWP-300A FWP-400A FWP-600A Virtual Pre-Arcing Time In Seconds 101 100 10-1 10-2 10-3 10-4 102 103 104 105 Prospective RMS ProspectiveCurrent CurrentInInAmperes Amps RMS Peak Let-Through Curve 105 B Peak Let-Through Current 104 FWP-600A FWP-400A FWP-300A FWP-200A FWP-150A 103 A 102 102 103 104 105 Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 361 110 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses North American -- FWJ 1000V: 35-2000A FWJ Arc Voltage Specifications Description: North American style stud-mount fuses. Dimensions: See Dimensions illustration. Ratings: Volts: -- 1000Vac Amps: -- 35-2000A IR: -- 25kA (35-200A) -- 100kA (250-2000A) -- 50kA @ 800Vdc (35200A, 450-600A) Agency Information: CE, UL Recognition File E91958 on 35-600A only. C 3.110 3.085 3.261 3.500 3.465 3.312 K Catalog Numbers 0.5 0.3 0.2 Eg 0.15 200 500 800 1000 E 4.180 4.156 4.055 4.150 4.706 4.962 F 0.352 0.352 0.445 0.433 0.562 0.625 G 0.750 1.000 1.000 1.500 2.000 2.750 H 0.125 0.188 0.250 0.250 0.375 0.500 I 0.380 0.407 0.819 0.764 1.201 0.880 1mm = 0.0394" / 1" = 25.4mm Fig. 1: 35-2000A A D E C H G F B J Data Sheet: 720027 Catalog Numbers FWJ-35A FWJ-40A FWJ-50A FWJ-60A FWJ-70A FWJ-80A FWJ-90A FWJ-100A FWJ-125A FWJ-150A FWJ-175A FWJ-200A FWJ-250A FWJ-300A FWJ-350A FWJ-400A FWJ-500A FWJ-600A FWJ-800A FWJ-1000A FWJ-1200A FWJ-1400A FWJ-1600A FWJ-1800A FWJ-2000A Rated Current RMS-Amps 35 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 500 600 800 1000 1200 1400 1600 1800 2000 600 1000 1400 1800 Kp Ib 30 40 50 1.0 D 4.235 4.266 4.803 4.811 5.984 5.472 400 High Speed Fuses B 0.940 1.125 1.526 2.000 2.500 3.500 800 Eg Watts loss at rated current is 1.0 given in the electrical characteristics. The curve 0.8 allows the calculation of the 0.6 0.5 power losses at load 0.4 currents lower than the 0.3 rated current. The correction factor, Kp, is 0.2 given as a function of the RMS load current, Ib, in % of the rated current. 0.1 Dimensions (in) Amp Range Fig. A 35-60 1 5.000 70-100 1 4.932 125-200 1 5.685 250-400 1 5.768 500-600 1 7.201 800-2000 1 6.811 1200 200 1.5 The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). UL 1600 Power Losses Electrical Characteristics Total Clearing I2t 2000 This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. 60 70 Electrical Characteristics I2t (A2 Sec) Clearing Pre-arc at 10 000V 210 2000 300 2500 470 3500 670 5000 1100 6900 1550 9700 1900 12000 2800 17500 4800 35000 6300 45000 7500 65000 11700 80000 16000 112000 23500 164000 33000 231000 47000 330000 39500 329000 61000 520000 87000 500000 190000 1100000 370000 2100000 470000 2700000 700000 4000000 925000 5300000 1330000 7600000 80 90 100% Watts Loss 7 8 10 11 12 13 14 15 16 25 30 32 50 56 62 67 95 105 182 206 240 248 267 239 244 * Watts loss provided at rated current. * See accessories on page 113. * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 111 High Speed Fuses North American -- FWJ 1000V: 35-2000A FWJ 35-600A: 1000V FWJ 800-2000A: 1000V Time-Current Curve Time-Current Curve 104 104 6 4 6 4 2 2 103 103 6 4 6 4 2 2 102 102 101 6 4 Virtual Pre-Arcing Time In Seconds 2 Virtual Pre-Arcing Time In Seconds 6 4 FWJ-200A FWJ-250A FWJ-300A FWJ-350A FWJ-400A FWJ-500A FWJ-600A 6 4 2 100 6 4 2 101 6 4 2 100 6 4 2 10-1 6 4 10-1 6 4 2 10-2 6 4 2 10-3 FWJ-800A FWJ-1000A FWJ-1200A FWJ-1400A FWJ-1600A FWJ-1800A FWJ-2000A 2 FWJ-40A FWJ-50A FWJ-60A FWJ-70A FWJ-80A FWJ-90A FWJ-100A FWJ-125A FWJ-150A FWJ-175A 2 10-2 6 4 2 10-3 6 4 6 4 2 10-4 2 10-4 102 2 4 6 8 2 103 4 6 8 2 4 6 8 2 103 4 6 8 104 Prospective Current In Amps RMS Data Sheet: 35785309 Peak Let-Through Curve 2 W -2000A W -1800A W -1600A W -1400A W -1250A W -1000A W -600A W -800A W -400A W -500A W -350A W -300A W -250A W -200A W -175A W -150A W -125A W -100A W -90A W -80A W -70A W -60A W -50A W -40A 105 6 4 ea Let-Through Current 2 104 6 4 2 103 6 4 2 102 102 2 4 6 2 103 4 6 104 2 4 6 105 2 4 6 rospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785303 112 104 2 Prospective Current In Amperes Prospective Current in AmpsRMS For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 4 6 8 105 High Speed Fuses North American Fuse Accessories Fuse Bases (Blocks) Modular Style Cooper Bussmann offers a comprehensive line of fuse bases that provide the user with design and manufacturing flexibility. Two identical half bases make up a Cooper Bussmann(R) modular fuse base. These "split" units can be panel mounted any distance apart to accommodate any length fuse. Stud Type (Not sold in pairs) C5268 Series Stud Type Connector Type High Speed Fuses The simpler design is the C5268 Series modular fuse base. With this design, the fuse terminal and cable (with termination) are mounted on the same stud, minimizing labor needed for installation. The stud type base is available in the configuration shown in the table below. Catalog Max Fuse Stud Stud Dia. Number Amp Rating Height (in) & Threads 5 C5268-1 200 1.00 16-18 5 C5268-2 200 1.75 16-18 5 C5268-3 200 0.75 16-18 1 C5268-4 100 1.00 4-20 1 C5268-5 100 1.75 4-20 BS Style Cooper Bussmann also offers a modular style fuse base that utilizes a tin-plated connector (for wire termination and heat dissipation) and a plated-steel stud (for fuse mounting). The connector type fuse base is available in the configurations shown below. Consult Cooper Bussmann for additional product details. Modular Max Max Fuse Data Sheet Base Style Voltage Amp Rating Number 1BS101 600 100 1206 1BS102 600 400 1207 1BS103 600 400 1208 1BS104 600 600 1209 BH-0xxx 700 100 1200 BH-1xxx 2500 400 1201 BH-2xxx 5000 400 1202 BH-3xxx 1250 700 1203 Connector Type Refer to page 275 for BH style holders. Fixed Center Fixed Center Base Style Cooper Bussmann offers a comprehensive line of fixed mount style fuse bases under the trademark TRON(R) rectifier fuse blocks. The cable and fuse connections are similar to the stud type fuse base -- both are mounted on the same stud. Consult Cooper Bussmann for complete product details. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 113 High Speed Fuses Square Body Fuses Introduction General Information Square Body Contents Page Application Information 115-116 Volts (IEC/UL) Size 000,00 690/700 1*, 1, 2, 3 1*, 2, 3 4 23, 24 00, 1, 2, 3 00 1000 1*, 1, 2, 3 4 24 1*, 1, 2, 3 1250/1300 1000-2000 DC Fuses 4 23 5 Class aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR Fuse Style DIN 43 653 Flush End Contact DIN 43 620 DIN 43 653 Flush End Contact US Style French Style Fuse Curves DIN 43 620 Flush End Contact Flush End Contact DIN 43 620 DIN 43 653 DIN 43 653 Flush End Contact US Style Fuse Curves Flush End Contact Flush End Contact DIN 43 653 Flush End Contact US Style Fuse Curves Flush End Contact Flush End Contact Flush End Contact Accessories Indicator System Fuse Bases Page 185 186 Square Body Fuse Ranges Amps 10-7500 50-1400 114 Volts 690 1250 AC X X Page 117-119 117-119 120-121 122-123 124-125 126-127 128-129 130-131 132-134 135-136 137-139 140-143 144-145 146-147 148-149 150-151 152-153 154-156 157-159 160-161 162-163 164-165 166-167 168-170 171-172 173 174-184 Designed and tested to: * IEC 60269: Part 4 * UL Recognized Cooper Bussmann offers a complete range of square body style fuses and accessories. Their unique design and construction provide: * Minimal energy let-through (I2t) * Low operating temperature * Low watts loss Square body style fuses are a very attractive solution for high power applications which require a compact design with superior performance. The construction and design of square body style fuses make it easy for Cooper Bussmann to manufacture custom products. Our cataloged offering provides only a sample of the wide variety of product which is available. Each square body style fuse is available with a number of different end fittings. Options include: * DIN 43 653 * DIN 43 620 * Flush End (Metric/US) * French Style * US Style Voltage Rating All Cooper Bussmann square body style fuses are tested to IEC 60269: Part 4. This standard requires a test voltage which is 5% higher than the rated voltage. In North America, fuses are required to clear only their rated voltage. Accessories Square Body style fuses are available with three different open fuse indicator systems. Options include visual indication and indication utilizing a microswitch. Fuse blocks are also available for most applications. DC -- -- For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body Applications Maximum Permissible Load Current Temperature Correction Curve The rated current value of Cooper Bussmann fuses is based on the ambient temperature in the space immediately below the fuse of 20C. The following graph gives correction factors (k) for a range of temperatures (-40C to +80C). Maximum permissible continuous load currents can be calculated by applying the following formula: k 1.2 1 0.8 0.6 - 40 - 20 0 20 40 60 80 C The maximum permissible continuous load current Ib of a fuse can be checked empirically (i.e., by satisfying the formula below) by making simple voltage and temperature measurements under actual operating conditions after the fuse has been installed in its operating location and loaded at the calculated Ib value: E2 5 (0.92 + 0.004t) ) N E1 where E1 = Voltage drop across fuse after 5 seconds E2 = Voltage drop across fuse after 2 hours t = Air temperature at start of test (C) N = Constant Fuse Rated Voltage (IEC) N 690 1.5 1250 1.6 Body Cross Section Standard fuse program includes barrels with different cross sections. Size 000 00 1 1 2 3 4 Maximum Cross-section (mm) 21 36 30 47 45 45 53 53 61 61 76 76 105 105 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 115 High Speed Fuses Ib ) In 5 k 5 (1 + 0.05 V) x Kb where Ib = Maximum permissible continuous load current In = Rated current of fuse k = Temperature correction factor v = Velocity of cooling air in m/s (max. 5 m/s). Kb = Fuse load constant 1.0 1.4 High Speed Fuses Square Body Applications Example Application of Square Body High Speed 170M3669 (400A) Fuses Subject to Overload and Impulse Loading Select a short-blade indicating fuse with indicator/adapter to permit the use of a single-pole microswitch for remote indication and determine if the fuse selected will meet the following application parameters. 103 Application Parameters -- 60 Seconds Once Per Hour 10 Seconds 2-3 Times Per Week 20 Seconds (max.) Once Per Month 0.5 Seconds Less Than Once Per Month 300A 500A 700A 1100A Voltage Data (5) Voltage Applied to Fuse During Fault Conditions (+10%) 102 Amps 400V A 101 Temperature Data (6) Temperature Inside Cubicle in Which Fuse is Located (Natural Convection Cooling Only) 60C A Profile Line (2) Overload (3a) (3b)Overload (4) Impulse Frequency of Occurrence Time In Seconds Load Currents Expected Load Type Duration (1) Normal Continuous 100 Thyrister Data (7) Thyrister Peak Voltage Withstand 1000V (8) Thyrister I2t Withstand at 10 Milliseconds* 90,000A2s *Note: The I2t withstand of the thyrister may be given for other impulse durations (i.e., 1.5 ms, 3.5 ms, or 8.3 ms); however, the stated fuse I2t is valid for all impulse durations of 10 ms or less. 10-1 Application Procedure Step Procedure (1) Select a short-blade fuse to permit mounting of microswitch 170H0069 1.1 Taking into consideration only the continuous load current and ambient temperature, from Table on page 127 tentatively select fuse 170M3669 400A, 690V). Remarks -- (2) Determine I2 t (total clearing) at 440V. 2.1 See Table, page 127. Note I2t is 105,000A2s at rated voltage of 690V. 2.2 From the figure on page 126, note that OK correction factor K = 0.65. 2.3 I2t660V K = I2t440V 105,000 0.65 = 68,250 (3) Determine maximum arc voltage at 440V 3.1 From the figure on page 126, note that OK maximum voltage at 440V is 900V (4) Determine maximum permissible continuous load current Ib. 4.1 Per page 115 data, Ib = In k (1 + 0.05V) Kb Ib = 400A 0.8 (1 + 0) 1 Ib = 320A (5) Plot a "line profile" showing the expected load and overload currents. Determine that overload and impulse load currents do not exceed their maximum permissible values. 5.0 Calculate Imax per Table, High Speed Fuse Application Guide page 16, for each overload and impulse load. (Item 2) 5.1 Imax < 60% It 500A < 60% 950A 500A < 570A OK 5.2 Imax < 60% It 700A < 60% 1360A 700A < 780A OK 5.3 Imax < 70% It 700A < 70% 1150A 700A < 805A OK 5.4 Imax < 70% It 1100A < 70% 1800A 1100A < 1260A OK (Item 3a) (Item 3b) (Item 4) -- 10-2 102 103 Current In Amperes Calculation of Watt Loss From the Table on page 127, watt loss at 400 amps is 60 watts. The continuous load current of 300A is 75% of rated current (400A). From page 126, the correction factor Kp = 0.5. Watt Loss 75% = Watt Loss 100% Kp = 60W 0.5 = 30 watts Special Fuses -- Other high speed fuses are available from Cooper Bussmann with voltage ratings of 380 to 10,000V and current ratings up to 10,000A in a single unit configuration. Fuses can be supplied with open fuse, "pin" indicators. Various types of microswitches are also available (see page 185). The tentatively selected fuse 170M3669 with microswitch 170H0069 meets all application parameters; no further selection would be necessary. 116 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body DIN 43 653 -- 690V/700V (IEC/UL): 10-400A 690V/700V (IEC/UL) 10-400A Arc Voltage Specifications Description: Square body DIN 43-653 stud mount high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 690Vac (IEC) -- 700Vac (UL) Amps: -- 10-400A IR: -- 200kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. UL Recognition/CSA Component Acceptance on Size 000. This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. E 21 30 F 20 28 4 Eg 3 200 300 400 500 600 690 K 1.0 0.5 0.4 0.3 0.2 Eg 100 200 300 400 500 600 690 G 51 67 H 8 10 1.0 Kp 0.8 0.6 0.5 High Speed Fuses 1.5 Dimensions (mm) Type -U/80, -/80, -TN/80 D 40 51 5 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Total Clearing I2t Size 000 00 UL Power Losses Electrical Characteristics The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1.4 1.2 103 9 8 7 6 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 80 90 100% For Other Voltage Ratings in This Body Style K 2 2 * See page 144 (1000V) 1mm = 0.0394" / 1" = 25.4mm Dimensions (mm) Type 00B/60, 00BTN/60 54 Indicator 1mm = 0.0394" / 1" = 25.4mm * M8 D K 6 64 30 54 Max G 100 78 48 E H F 62 * Indication for Size 00 fuses is a red pin. Indicator For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 117 High Speed Fuses Square Body DIN 43 653 -- 690V/700V (IEC/UL): 10-400A Catalog Numbers -U/80 Without Indicator 170M1308 170M1309 170M1310 170M1311 170M1312 170M1313 170M1314 170M1315 170M1316 170M1317 170M1318 170M1319 170M1320 170M1321 170M1322 * * * * Catalog Numbers -TN/80 -/80 Type T Visual Indicator Indicator for Micro 170M1358 170M1408 170M1359 170M1409 170M1360 170M1410 170M1361 170M1411 170M1362 170M1412 170M1363 170M1413 170M1364 170M1414 170M1365 170M1415 170M1366 170M1416 170M1367 170M1417 170M1368 170M1418 170M1369 170M1419 170M1370 170M1420 170M1371 170M1421 170M1372 170M1422 170M2608 170M2658 170M2609 170M2659 170M2610 170M2660 170M2611 170M2661 170M2612 170M2662 170M2613 170M2663 170M2614 170M2664 170M2615 170M2665 170M2616 170M2666 170M2617 170M2667 170M2618 170M2668 170M2619 170M2669 170M2620 170M2670 170M2621 170M2671 00B/60 Visual Indicator 00BTN/60 Type T Indicator fo or Micro Electrical Characteristics Size 000 170M2708 170M2709 170M2710 170M2711 170M2712 170M2713 170M2714 170M2715 170M2716 170M2717 170M2718 170M2719 170M2720 170M2721 170M2758 170M2759 170M2760 170M2761 170M2762 170M2763 170M2764 170M2765 170M2766 170M2767 170M2768 170M2769 170M2770 170M2771 00 Rated Current RMS-Amps 10 16 20 25 32 40 50 63 80 100 125 160 200 250 315 25 32 40 50 63 80 100 125 160 200 250 315 350 400 I2t (A2 Sec) Clearing Pre-arc at 660V 3.8 25.5 7.2 48 11.5 78 19 130 40 270 69 460 115 770 215 1450 380 2550 695 4650 1200 8500 2300 16000 4200 28000 7750 51500 12000 80500 19 130 28.5 195 50 360 95 640 170 1200 310 2100 620 4150 1000 6950 1900 13000 3400 23000 6250 42000 10000 68500 13500 91500 18000 125000 Watts Loss 3.0 5.5 7 9 10 12 15 16 19 24 28 32 37 42 52 6 7 9 10 12 15 20 25 30 35 45 55 60 70 Watts loss provided at rated current. Microswitch indicator ordered separately. See accessories on pages 185-186. For fuse curves see page 119. 118 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body Size 000, 00 -- 690V/700V (IEC/UL): 10-400A 25A 32A 40A 50A 63A 80A 100A 125A 160A 200A 250A 315A 350A 400A 80A 100A 125A 160A 200A 250A 315A 32A 40A 50A 63A Time-Current Curve 16A 20A 25A Size 00 -- 25-400A: 690V Time-Current Curve 10A Size 000 -- 10-315A: 690V 104 104 103 103 102 102 Virtual Pre-Arcing Time In Seconds 10 A A 1 100 10-1 10-2 10-1 10-3 1x101 102 103 Prospective Current In Amps RMS 104 Peak Let-Through Curve 1x10-4 1x101 102 103 Prospective Current in Amps RMS 104 Peak Let-Through Curve 315A B 103 250A 200A 160A 125A 100A 80A 63A 50A 40A 32A 25A 20A 16A 10A 400A 350A 315A 250A 200A 160A 125A 100A 80A 63A 50A 40A 32A 25A 104 B Peak Let-Through Current 104 Peak Let-Through Current 100 10-2 10-3 1x10-4 A 101 High Speed Fuses Virtual Pre-Arcing Time In Seconds A 103 102 102 A A 2x101 2x10 1x101 102 103 104 Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 17056310 105 1 1x101 102 103 104 105 Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 172056312 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 119 High Speed Fuses Square Body DIN 43 620 -- 690V (IEC/UL): 10-315A 690V (IEC/UL) 10-315A Arc Voltage Specifications Description: Square body DIN 43 620 blade style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 690Vac Amps: -- 10-315A IR: -- 200kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Electrical Characteristics Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters Dimensions (mm) DIN 000 Type T 1mm = 0.0394" / 1" = 25.4mm 54 Max Indicator 15 48 79 21 6 35 120 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body DIN 43 620 -- 690V (IEC/UL): 10-315A Size 000 -- 10-315A: 690V Catalog Numbers Time-Current Curve Electrical Characteristics Size 000 00 Rated Current RMS-Amps 10 16 20 25 32 40 50 63 80 100 125 160 200 250 315 I2t (A2 Sec) Clearing Pre-arc at 660V 4 27 7 51 11.5 82.5 19 140 40 285 65 490 115 815 215 1550 380 2700 695 4950 1180 8250 2300 16500 4350 31000 7900 56000 12000 84500 Watts Loss 2.5 4 5 6 7 8.5 9.5 11.5 15 16.5 21.5 25 29.5 35.5 45 High Speed Fuses Catalog Numbers DIN Type T Indicator for Micro 170M1558D 170M1559D 170M1560D 170M1561D 170M1562D 170M1563D 170M1564D 170M1565D 170M1566D 170M1567D 170M1568D 170M1569D 170M1570D 170M1571D 170M1572D * Watts loss provided at rated current. * Microswitch indicator ordered separately. See accessories on pages 185-186. Rated Current The rated current of this fuse range has been given with copper conductors that have a current density of 1.3 A/mm2 (IEC 60269-4). For conductor cross section according to IEC 60269-1, the fuses with a rated current higher than 125A must be derated. Please contact Cooper Bussmann for application assistance. Peak Let-Through Curve Data Sheet: 72056310 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 121 High Speed Fuses Square Body DIN 43 653 -- 690V/700V (IEC/UL): 40-2000A 690V/700V (IEC/UL) 40-2000A Arc Voltage Specifications Description: Square body DIN 43 653 stud-mount high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 690Vac (IEC) -- 700Vac (UL) Amps: -- 40-2000A IR: -- 200kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. Consult Cooper Bussmann for UL Recognition/CSA Component Acceptance status. This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. K Dimensions (mm) Size 1* 1 2 3 A 50 50 50 51 B 104 108 108 109 B** 134 138 138 139 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. 2) 1) 1.0 0.5 0.4 0.3 4 Eg Eg 100 200 300 400 500 600 690 1) Rated voltage 600V 2) Rated voltage 550V C** 108 108 108 108 D*** 58 66 75 90 E 45 53 61 76 300 400 500 600 690 1.0 Kp 0.8 0.6 0.5 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 0.2 C 78 78 78 78 5 200 Power Losses 1.5 The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). UL 3 Electrical Characteristics Total Clearing I2t 1.4 1.2 103 9 8 7 6 80 90 100% For Other Voltage Ratings in This Body Style H 22 25 25 30 * See pages 146 (1000V) and 160 (1250V/1300V) **Valid for fuses type -/110, -TN/110. ***Microswitch. 1mm = 0.0394" / 1" = 25.4mm Type -KN/80, -KN/110 C A Type -/80, -TN/80, -/110, -TN/110. C A H 11 H D 11 B E D E B 6 6 E E 122 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body DIN 43 653 -- 690V/700V (IEC/UL): 40-2000A Catalog Numbers -TN/80 Type T Indicator for Micro 170M3058 170M3059 170M3060 170M3061 170M3062 170M3063 170M3064 170M3065 170M3066 170M3067 170M3068 170M3069 170M3070 170M3071 170M3072 170M3073 170M4058 170M4059 170M4060 170M4061 170M4062 170M4063 170M4064 170M4065 170M4066 170M4067 170M4068 170M4069 170M5058 170M5059 170M5060 170M5061 170M5062 170M5063 170M5064 170M5065 170M5066 170M5067 170M5068 170M6058 170M6059 170M6060 170M6061 170M6062 170M6063 170M6064 170M6065 170M6066 170M6067 170M6068 170M6069 170M6070 170M6071 Catalog Numbers -KN/80 Type K -/110 Indicator Visual for Micro for Micro 170M3108 170M3158 170M3109 170M3159 170M3110 170M3160 170M3111 170M3161 170M3112 170M3162 170M3113 170M3163 170M3114 170M3164 170M3115 170M3165 170M3116 170M3166 170M3117 170M3167 170M3118 170M3168 170M3119 170M3169 170M3120 170M3170 170M3121 170M3171 170M3122 170M3172 170M3123 170M3173 170M4108 170M4158 170M4109 170M4159 170M4110 170M4160 170M4111 170M4161 170M4112 170M4162 170M4113 170M4163 170M4114 170M4164 170M4115 170M4165 170M4116 170M4166 170M4117 170M4167 170M4118 170M4168 170M4119 170M4169 170M5108 170M5158 170M5109 170M5159 170M5110 170M5160 170M5111 170M5161 170M5112 170M5162 170M5113 170M5163 170M5114 170M5164 170M5115 170M5165 170M5116 170M5166 170M5117 170M5167 170M5118 170M5168 170M6108 170M6158 170M6109 170M6159 170M6110 170M6160 170M6111 170M6161 170M6112 170M6162 170M6113 170M6163 170M6114 170M6164 170M6115 170M6165 170M6116 170M6166 170M6117 170M6167 170M6118 170M6168 170M6119 170M6169 170M6120 170M6170 170M6121 170M6171 -TN/110 Type T Indicator for Micro 170M3208 170M3209 170M3210 170M3211 170M3212 170M3213 170M3214 170M3215 170M3216 170M3217 170M3218 170M3219 170M3220 170M3221 170M3222 170M3223 170M4208 170M4209 170M4210 170M4211 170M4212 170M4213 170M4214 170M4215 170M4216 170M4217 170M4218 170M4219 170M5208 170M5209 170M5210 170M5211 170M5212 170M5213 170M5214 170M5215 170M5216 170M5217 170M5218 170M6208 170M6209 170M6210 170M6211 170M6212 170M6213 170M6214 170M6215 170M6216 170M6217 170M6218 170M6219 170M6220 170M6221 -KN/110 Type K Indicator -KN/80 170M3258 170M3259 170M3260 170M3261 170M3262 170M3263 170M3264 170M3265 170M3266 170M3267 170M3268 170M3269 170M3270 170M3271 170M3272 170M3273 170M4258 170M4259 170M4260 170M4261 170M4262 170M4263 170M4264 170M4265 170M4266 170M4267 170M4268 170M4269 170M5258 170M5259 170M5260 170M5261 170M5262 170M5263 170M5264 170M5265 170M5266 170M5267 170M5268 170M6258 170M6259 170M6260 170M6261 170M6262 170M6263 170M6264 170M6265 170M6266 170M6267 170M6268 170M6269 170M6270 170M6271 Electrical Characteristics Size 1* 1 2 3 Rated RMS-Amps 40 50 63 80 100 125 160 200 250 315 350 400 450 500 550 630 200 250 315 350 400 450 500 550 630 700 800 900 400 450 500 550 630 700 800 900 1000 1100 1250 500 550 630 700 800 900 1000 1100 1250 1400 1500 1600 1800 2000 I2t (A2 Sec) Current Pre-arc at 660V 40 270 77 515 115 770 185 1250 360 2450 550 3700 1100 7500 2200 15000 4200 28500 7000 46500 10000 68500 15000 105000 21000 140000 27000 180000 34000 230000 48500 325000 1650 11500 3100 21000 6200 42000 8500 59000 13500 91500 17000 120000 25000 170000 34000 230000 52000 350000 69500 465000 105000 725000 155000 850000 11000 74000 15500 105000 21500 145000 28000 190000 41000 275000 60500 405000 86000 575000 125000 840000 180000 1250000 245000 1600000 365000 2400000 14000 95000 19500 135000 31000 210000 44500 300000 69500 465000 100000 670000 140000 945000 190000 1300000 290000 1950000 370000 2450000 460000 3100000 580000 3900000 880000 5250000 1150000 6350000 Clearing Loss 9 11 14 18 21 26 30 35 40 50 55 60 65 70 75 80 45 55 58 60 65 70 72 75 80 85 95 100 65 70 75 80 90 95 105 110 115 120 130 95 100 105 110 115 120 125 130 140 155 160 160 165 175 Rated voltage (IEC) 600V. Rated voltage (IEC) 550V. * Watts loss provided at rated current. * Microswitch indicator ordered separately. See accessories on pages 185-186. * For fuse curves see pages 130 and 131. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 123 High Speed Fuses -/80 Visual Watts Indicator 170M3008 170M3009 170M3010 170M3011 170M3012 170M3013 170M3014 170M3015 170M3016 170M3017 170M3018 170M3019 170M3020 170M3021 170M3022 170M3023 170M4008 170M4009 170M4010 170M4011 170M4012 170M4013 170M4014 170M4015 170M4016 170M4017 170M4018 170M4019 170M5008 170M5009 170M5010 170M5011 170M5012 170M5013 170M5014 170M5015 170M5016 170M5017 170M5018 170M6008 170M6009 170M6010 170M6011 170M6012 170M6013 170M6014 170M6015 170M6016 170M6017 170M6018 170M6019 170M6020 170M6021 High Speed Fuses Square Body Flush End Contact -- 690V/700V (IEC/UL): 40-2000A 690V/700V (IEC/UL) 40-2000A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: Square body flush end contact high speed fuses. Dimensions: See dimensions illustrations. Ratings: Volts: -- 690Vac (IEC) -- 700Vac (UL) Amps: -- 40-2000A IR: -- 200kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. Consult Cooper Bussmann for UL Recognition / CSA Component Acceptance Status. The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1.5 K 2) 1) 1.0 0.5 0.4 0.3 5 4 Eg 200 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Total Clearing I2t UL 3 Power Losses Electrical Characteristics 1.4 1.2 103 9 8 7 6 300 400 500 600 690 1.0 Kp 0.8 0.6 0.5 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 80 90 100% 0.2 Eg 100 200 300 400 500 600 690 1) Rated voltage 600V. 2) Rated voltage 550V For Other Voltage Ratings in This Body Style * See pages 148 (1000V) and 162 (1250V/1300V) Dimensions (mm) Type -B/-, -BKN/-, -G/-, -GKN/Size 1* 1 2 3 A 50 50 50 51 B 51 51 51 53 D 59 69 77 92 E 45 53 61 76 F M8 M8 M10 M12 F** (in) 16" - 18 UNC-2B 16" - 18 UNC-2B 3 8" - 16 UNC-2B 1 2" - 13 UNC-2B 5 5 B G 5 8 10 10 H o17 o20 o24 o30 **Valid for fuses type -G/- & -GKN/-. NB: B = 65 for: Size 2, 1100-1250A Size 3, 1600-2000A 1mm = 0.0394" / 1" = 25.4mm D A E F E H G 124 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body Flush End Contact -- 690V/700V (IEC/UL): 40-2000A Catalog Numbers -GKN/Type K Indicator for Micro 170M3558 170M3559 170M3560 170M3561 170M3562 170M3563 170M3564 170M3565 170M3566 170M3567 170M3568 170M3569 170M3570 170M3571 170M3572 170M3573 170M4558 170M4559 170M4560 170M4561 170M4562 170M4563 170M4564 170M4565 170M4566 170M4567 170M4568 170M4569 170M5558 170M5559 170M5560 170M5561 170M5562 170M5563 170M5564 170M5565 170M5566 170M5567 170M5568 170M6558 170M6559 170M6560 170M6561 170M6562 170M6563 170M6564 170M6565 170M6566 170M6567 170M6568 170M6569 170M6570 170M6571 Electrical Characteristics Size 1* 1 2 3 Rated I2t (A2 Sec) Current Clearing RMS-A Amps Pre-arc at 660V 40 40 270 50 77 515 63 115 770 80 185 1250 100 360 2450 125 550 3700 160 1100 7500 200 2200 15000 250 4200 28500 315 7000 46500 350 10000 68500 400 15000 105000 450 21000 140000 500 27000 180000 550 34000 230000 630 48500 325000 200 1650 11500 250 3100 21000 315 6200 42000 350 8500 59000 400 13500 91500 450 17000 120000 500 25000 170000 550 34000 230000 630 52000 350000 700 69500 465000 800 105000 725000 900 155000 850000 400 11000 74000 450 15500 105000 500 21500 145000 550 28000 190000 630 41000 275000 700 60500 405000 800 86000 575000 900 125000 840000 1000 180000 1250000 1100 245000 1600000 1250 365000 2400000 500 14000 95000 550 19500 135000 630 31000 210000 700 44500 300000 800 69500 465000 900 100000 670000 1000 140000 945000 1100 190000 1300000 1250 290000 1950000 1400 370000 2450000 1500 460000 3100000 1600 580000 3900000 1800 880000 5250000 2000 1150000 6350000 Watts Loss 9 11 14 18 21 26 30 35 40 50 55 60 65 70 75 80 45 55 58 60 65 70 72 75 80 85 95 100 65 70 75 80 90 95 105 110 115 120 130 95 100 105 110 115 120 125 130 140 155 160 160 165 175 High Speed Fuses -B/Visual Indicator 170M3408 170M3409 170M3410 170M3411 170M3412 170M3413 170M3414 170M3415 170M3416 170M3417 170M3418 170M3419 170M3420 170M3421 170M3422 170M3423 170M4408 170M4409 170M4410 170M4411 170M4412 170M4413 170M4414 170M4415 170M4416 170M4417 170M4418 170M4419 170M5408 170M5409 170M5410 170M5411 170M5412 170M5413 170M5414 170M5415 170M5416 170M5417 170M5418 170M6408 170M6409 170M6410 170M6411 170M6412 170M6413 170M6414 170M6415 170M6416 170M6417 170M6418 170M6419 170M6420 170M6421 Catalog Numbers -BKN/Type K -G/Indicator Visual for Micro Indicator 170M3458 170M3508 170M3459 170M3509 170M3460 170M3510 170M3461 170M3511 170M3462 170M3512 170M3463 170M3513 170M3464 170M3514 170M3465 170M3515 170M3466 170M3516 170M3467 170M3517 170M3468 170M3518 170M3469 170M3519 170M3470 170M3520 170M3471 170M3521 170M3472 170M3522 170M3473 170M3523 170M4458 170M4508 170M4459 170M4509 170M4460 170M4510 170M4461 170M4511 170M4462 170M4512 170M4463 170M4513 170M4464 170M4514 170M4465 170M4515 170M4466 170M4516 170M4467 170M4517 170M4468 170M4518 170M4469 170M4519 170M5458 170M5508 170M5459 170M5509 170M5460 170M5510 170M5461 170M5511 170M5462 170M5512 170M5463 170M5513 170M5464 170M5514 170M5465 170M5515 170M5466 170M5516 170M5467 170M5517 170M5468 170M5518 170M6458 170M6508 170M6459 170M6509 170M6460 170M6510 170M6461 170M6511 170M6462 170M6512 170M6463 170M6513 170M6464 170M6514 170M6465 170M6515 170M6466 170M6516 170M6467 170M6517 170M6468 170M6518 170M6469 170M6519 170M6470 170M6520 170M6471 170M6521 Rated voltage (IEC) 600V. Rated voltage (IEC) 550V. * Watts loss provided at rated current. * Microswitch indicator ordered separately. See accessories on pages 185-186. * For fuse curves see pages 130 and 131. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 125 High Speed Fuses Square Body US Style -- 690V/700V (IEC): 40-2000A 690V/700V (IEC) 40-2000A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: Square body US style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 690Vac (IEC) -- 700Vac (UL) Amps: -- 40-200A IR: -- 200kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. Consult Cooper Bussmann for UL Recognition/ CSA Component Acceptance status. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Total Clearing I2t 1.5 K 2) 1) 1.0 0.5 0.4 0.3 * * * * Dimensions (mm) Type -FU/-, -FKE/-, FU/115-, -FKE/115 B 110 136 135 135 B** 148 157 159 155 C1 85 104 105 106 C1** 123 126 125 125 4 Eg 200 C2 72 78 78 77 C2** 110 100 99 97 D 59 69 77 92 E 45 53 61 76 H 20 25 25 36 I 10 14 14 16 0.3 0.2 Ib 0.1 30 40 50 126 60 70 Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters For Other Voltage Ratings in This Body Style * See pages 150 (1000V) and 164 (1250V/1300V) A C1 C2 I 600 690 0.4 6 E 500 0.6 0.5 B E 400 1.0 Kp 0.8 **Valid for fuses type -FU/115 & -FKE/115. 1mm = 0.0394" / 1" = 25.4mm D 300 0.2 1) Rated voltage 600V. 2) Rated voltage 550V A 50 50 50 51 5 Features and Benefits * Excellent DC performance * Low arc voltage and low energy let-through (I2t) * Low watts loss * Superior cycling capability 100 200 300 400 500 600 690 Size 1* 1 2 3 UL 3 Electrical Characteristics The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1.4 1.2 103 9 8 7 6 H For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 80 90 100% High Speed Fuses Square Body US style -- 690V/700V (IEC): 40-2000A Catalog Numbers -FKE/115 Type K Indicator for Micro 170M3758 170M3759 170M3760 170M3761 170M3762 170M3763 170M3764 170M3765 170M3766 170M3767 170M3768 170M3769 170M3770 170M3771 170M3772 170M3773 170M4758 170M4759 170M4760 170M4761 170M4762 170M4763 170M4764 170M4765 170M4766 170M4767 170M4768 170M4769 170M5758 170M5759 170M5760 170M5761 170M5762 170M5763 170M5764 170M5765 170M5766 170M5767 170M5768 170M6758 170M6759 170M6760 170M6761 170M6762 170M6763 170M6764 170M6765 170M6766 170M6767 170M6768 170M6769 170M6770 170M6771 Electrical Characteristics Size 1* 1 2 3 Rated Current RMS S-Amps 40 50 63 80 100 125 160 200 250 315 350 400 450 500 550 630 200 250 315 350 400 450 500 550 630 700 800 900 400 450 500 550 630 700 800 900 1000 1100 1250 500 550 630 700 800 900 1000 1100 1250 1400 1500 1600 1800 2000 I2t (A2 Sec) Clearing Pre-arc at 660V 40 270 77 515 115 770 185 1250 360 2450 550 3700 1100 7500 2200 15000 4200 28500 7000 46500 10000 68500 15000 105000 21000 140000 27000 180000 34000 230000 48500 325000 1650 11500 3100 21000 6200 42000 8500 59000 13500 91500 17000 120000 25000 170000 34000 230000 52000 350000 69500 465000 105000 725000 155000 850000 11000 74000 15500 105000 21500 145000 28000 190000 41000 275000 60500 405000 86000 575000 125000 840000 180000 1250000 245000 1600000 365000 2400000 14000 95000 19500 135000 31000 210000 44500 300000 69500 465000 100000 670000 140000 945000 190000 1300000 290000 1950000 370000 2450000 460000 3100000 580000 3900000 880000 5250000 1150000 6350000 Watts Loss 9 11 14 18 21 26 30 35 40 50 55 60 65 70 75 80 45 55 58 60 65 70 72 75 80 85 95 100 65 70 75 80 90 95 105 110 115 120 130 95 100 105 110 115 120 125 130 140 155 160 160 165 175 High Speed Fuses -FU/Without Indicator 170M3608 170M3609 170M3610 170M3611 170M3612 170M3613 170M3614 170M3615 170M3616 170M3617 170M3618 170M3619 170M3620 170M3621 170M3622 170M3623 170M4608 170M4609 170M4610 170M4611 170M4612 170M4613 170M4614 170M4615 170M4616 170M4617 170M4618 170M4619 170M5608 170M5609 170M5610 170M5611 170M5612 170M5613 170M5614 170M5615 170M5616 170M5617 170M5618 170M6608 170M6609 170M6610 170M6611 170M6612 170M6613 170M6614 170M6615 170M6616 170M6617 170M6618 170M6619 170M6620 170M6621 Catalog Numbers -FKE/Type K -FU/115 Indicator Without for Micro Indicator 170M3658 170M3708 170M3659 170M3709 170M3660 170M3710 170M3661 170M3711 170M3662 170M3712 170M3663 170M3713 170M3664 170M3714 170M3665 170M3715 170M3666 170M3716 170M3667 170M3717 170M3668 170M3718 170M3669 170M3719 170M3670 170M3720 170M3671 170M3721 170M3672 170M3722 170M3673 170M3723 170M4658 170M4708 170M4659 170M4709 170M4660 170M4710 170M4661 170M4711 170M4662 170M4712 170M4663 170M4713 170M4664 170M4714 170M4665 170M4715 170M4666 170M4716 170M4667 170M4717 170M4668 170M4718 170M4669 170M4719 170M5658 170M5708 170M5659 170M5709 170M5660 170M5710 170M5661 170M5711 170M5662 170M5712 170M5663 170M5713 170M5664 170M5714 170M5665 170M5715 170M5666 170M5716 170M5667 170M5717 170M5668 170M5718 170M6658 170M6708 170M6659 170M6709 170M6660 170M6710 170M6661 170M6711 170M6662 170M6712 170M6663 170M6713 170M6664 170M6714 170M6665 170M6715 170M6666 170M6716 170M6667 170M6717 170M6668 170M6718 170M6669 170M6719 170M6670 170M6720 170M6671 170M6721 Rated voltage (IEC) 600V. Rated voltage (IEC) 550V. * Watts loss provided at rated current. * Microswitch indicator ordered separately. See accessories on pages 185-186. * For fuse curves see pages 130 and 131. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 127 High Speed Fuses Square Body French Style -- 690V/700V (IEC/UL): 40-1500A 690V/700V (IEC/UL) 40-1500A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: Square body French style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 690Vac (IEC) -- 700Vac (UL) Amps: -- 40-1500A IR: -- 200kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. K 1.0 0.2 Eg 4 Eg 200 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. 1.5 0.3 5 Power Losses Total Clearing I2t 0.5 0.4 UL 3 Electrical Characteristics The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1.4 1.2 103 9 8 7 6 A 50 50 50 51 B 102 111 126 126 C 76 86 91 91 400 500 0.6 0.5 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 100 200 300 400 500 600 690 600 690 1.0 Kp 0.8 Dimensions (mm) Type -E/-, -EKN/Size 1* 1 2 3 300 80 90 100% C D 59 69 77 92 E 45 53 61 76 H 18 25 30 36 I 9 11 13 13 J 13 11 12 13 A 1mm = 0.0394" / 1" = 25.4mm H I D J B E 6 E 128 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body French Style -- 690V/700V (IEC/UL): 40-1500A Catalog Numbers Virtual Pre-Arcing Time In Seconds Electrical Characteristics 400A 450A 500A 550A 630A 700A 800A 900A 1000A 1100A 1250A Rated I2t (A2 Sec) Current Clearing Watts Size RMS-Amps Pre-arc at 660V Loss 40 40 270 9 50 77 515 11 63 115 770 14 80 185 1250 18 100 360 2450 21 125 550 3700 26 160 1100 7500 30 1* 200 2200 15000 35 250 4200 28500 40 315 7000 46500 50 350 10000 68500 55 A 400 A 15000 105000 60 450 21000 140000 65 500 27000 180000 70 200 1650 11500 45 250 3100 21000 55 315 6200 42000 58 350 8500 59000 60 400 13500 91500 65 1 450 17000 120000 70 500 25000 170000 72 550 34000 230000 75 630 52000 350000 80 700 69500 465000 85 800 105000 725000 95 400 11000 74000 65 450 15500 105000 70 500 21500 145000 75 550 28000 190000 80 2 630 41000 275000 90 700 60500 405000 95 800 86000 575000 105 900 125000 840000 110 4 103 10 1000 180000 1250000 105 115 Prospective Current In Amperes RMS 500 14000 95000 95 550 19500 135000 100 630 31000 210000 105 700 44500 300000 110 800 69500 465000 115 3 900 100000 670000 120 1000 140000 945000 125 1100 190000 1300000 130 1250 290000 1950000 140 1400 370000 2450000 155 1500 460000 3100000 160 High Speed Fuses Catalog Numbers -E/ -EKN/Type T Type K Indicator Indicato or For Micro for Micro 170M3308 170M3358 170M3309 170M3359 104 170M3310 170M3360 170M3311 170M3361 170M3312 170M3362 170M3313 170M3363 103 170M3314 170M3364 170M3315 170M3365 170M3316 170M3366 170M3317 170M3367 102 170M3318 170M3368 170M3319 170M3369 170M3320 170M3370 170M3321 170M3371 101 170M4308 170M4358 170M4309 170M4359 170M4310 170M4360 0 10 170M4311 170M4361 170M4312 170M4362 170M4313 170M4363 170M4314 170M4364 -1 10 170M4315 170M4365 170M4316 170M4366 170M4317 170M4367 170M4318 170M4368 -2 10 170M5308 170M5358 170M5309 170M5359 170M5310 170M5360 170M5311 170M5361 10-3 170M5312 170M5362 170M5313 170M5363 170M5314 170M5364 170M5315 170M5365 1x10-4 1x102 170M5366 170M5316 170M6308 170M6358 170M6309 170M6359 170M6310 170M6360 170M6311 170M6361 170M6312 170M6362 170M6313 170M6363 170M6314 170M6364 170M6315 170M6365 170M6316 170M6366 170M6317 170M6367 170M6318 170M6368 * Watts loss provided at rated current. * Microswitch indicator ordered separately. See accessories on pages 185-186. * For fuse curves see pages 130 and 131. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 129 High Speed Fuses Square Body Size 1*, 1 -- 690V/700V (IEC/UL): 40-2000A Time-Current Curve 315A 350A 400A 450A 500A 550A 630A 700A 800A 900A Size 1 -- 200-900A: 690V Time-Current Curve 200A 250A Size 1* -- 40-630A: 690V 104 103 102 A Virtual Pre-Arcing Time In Seconds A 101 100 10-1 10-2 10-3 1x10-4 1x102 103 104 105 Prospective Current In Amps RMS Peak Let-Through Curve Peak Let-Through Curve 105 105 B 630A 550A 500A 450A 400A 350A 315A 250A 200A 160A 125A 100A 80A 63A 50A 40A 104 900A 700A 550A 450A 350A Peak Let-Through Current Peak Let-Through Current B 250A 200A 104 103 103 A A 2x10 2x10 2 1x102 103 104 105 Prospective Short-Circuit Current Symmetrical RMS 106 2 1x102 103 104 900 amp fuse is derated to 550V (IEC). Data Sheet: 17056314 130 Data Sheet: 17056316 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 105 106 800A 630A 500A 400A 315A High Speed Fuses Square Body Size 2, 3 -- 690V/700V (IEC/UL): 40-2000A Size 3 -- 500-2000A: 690V Time-Current Curve Time-Current Curve 104 104 103 103 102 102 A Virtual Pre-Arcing Time In Seconds A 101 100 10-1 101 100 10-1 10-2 10-2 10-3 10-3 1x102 103 104 1x10-4 105 1x102 Prospective Current In Amps RMS Peak Let-Through Curve 103 104 Prospective Current In Amps RMS 105 Peak Let-Through Curve 106 106 B B 1250A 1000A 800A 630A 500A 400A 105 1100A 900A 700A 550A 450A Peak Let-Through Current Peak Let-Through Current A High Speed Fuses Virtual Pre-Arcing Time In Seconds A 1x10-4 500A 550A 630A 700A 800A 900A 1000A 1100A 1250A 1400A 1500A 1600A 1800A 2000A 400A 450A 500A 550A 630A 700A 800A 900A 1000A 1100A 1250A Size 2 -- 400-1250A: 690V 1800A 1500A 1250A 1000A 800A 630A 500A 105 2000A 1600A 1400A 1100A 900A 700A 550A 104 104 A A 2x10 2x103 1x103 104 105 106 Prospective Short-Circuit Current Symmetrical RMS 107 3 1x103 104 105 106 Prospective Short-Circuit Current Symmetrical RMS 107 1800A fuse is derated to 600V (IEC). 2000A fuse is derated to 550V (IEC). Data Sheet: 17056318 Data Sheet: 17056320 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 131 High Speed Fuses Square Body DIN 43 620 -- 690V/700V (IEC/UL): 40-1000A 690V/700V (IEC/UL) 40-1000A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: Square body DIN 43 620 blade style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 690Vac (IEC) -- 700Vac (UL) Amps: -- 40-1000A IR: -- 200kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Electrical Characteristics Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters For Full Range Fuses in This Body Style * See page 140 Dimensions (mm) Type DIN 1*, DIN 2, DIN 3 Size 1* 2 3 A 69 69 68 B 135 150 150 D 58 71 88 A E 45 55 76 F 40 48 60 H 20 26 33 Indicator H 1mm = 0.0394" / 1" = 25.4mm D F B E 132 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 6 High Speed Fuses Square Body DIN 43 620 -- 690V/700V (IEC/UL): 40-600A Size 1* -- 40-630A: 690V Catalog Numbers Size 1* 2 3 Electrical Characteristics Rated I2t (A2Sec) Current Clearing RMS-Amps Pre-arc at 660V 40 40 285 50 78 550 63 120 850 80 185 1350 100 360 2600 125 550 3900 160 1150 8250 200 2300 16500 250 4350 31000 315 7300 52000 350 10000 73000 400 16000 115000 450 21500 155000 500 27000 190000 550 33500 240000 630 48500 345000 700 69500 495000 400 11000 79000 450 16000 115000 500 21500 155000 550 29000 215000 630 41000 295000 700 60500 430000 800 86000 610000 900 125000 895000 1000 180000 1300000 1100 245000 1750000 500 14000 99500 550 19500 140000 630 31000 220000 700 45000 320000 800 69500 490000 900 100000 720000 1000 140000 985000 1100 190000 1400000 1250 300000 2150000 1400 380000 2700000 1500 470000 3350000 1600 585000 4150000 Time-Current Curve Watts Loss 4 4.5 6.5 8.5 10 11 12 12.5 16 20 21.5 60 26.3 28.5 33 37.5 39 29 32 34 36 42 43 48 52 53 56 43 44 45 46 48 50 56 57 61 70 72 74 * Watts loss provided at rated current. * Microswitch indicator ordered separately. See accessories on pages 185-186. * For fuse curves see page 134. High Speed Fuses Catalog Numbers DIN Type T Indicator for Micro 170M3808D 170M3809D 170M3810D 170M3811D 170M3812D 170M3813D 170M3814D 170M3815D 170M3816D 170M3817D 170M3818D 170M3819D 170M4863D 170M4864D 170M4865D 170M4866D 170M4867D 170M5808D 170M5809D 170M5810D 170M5811D 170M5812D 170M5813D 170M5814D 170M5820D 170M5816D 170M5817D 170M6808D 170M6809D 170M6810D 170M6811D 170M6812D 170M6813D 170M6814D 170M6892D 170M8554D 170M8555D 170M8556D 170M8557D Peak Let-Through Curve Rated Current The rated current of this fuse range has been given with copper conductors that have a current density of 1.3 A/mm2 (IEC 60269-4). For conductor cross section according to IEC 60269-1, the fuses must be derated. Please contact Cooper Bussmann for application assistance. Data Sheet: 17056314 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 133 High Speed Fuses Square Body DIN 43 620 -- 690V/700V (IEC/UL): 40-1000A Size 2 -- 400-1250A: 690V Size 3 -- 500-2000A: 690V Time-Current Curve Time-Current Curve Peak Let-Through Curve Data Sheet: 17056318 134 Peak Let-Through Curve Data Sheet: 17056320 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body Flush End Contact -- 690/700V (IEC/UL): 1000-4000A 690V (IEC) 1000-4000A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: Square body flush end contact high speed fuses. Dimensions: See dimensions illustrations. Ratings: Volts: -- 690Vac Amps: -- 1000-4000A IR: -- 200kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. Power Losses 1.5 1) K 1.0 0.5 0.4 0.3 0.2 Eg 100 200 300 400 500 600 690 1) Rated voltage 500V Dimensions (mm) Type 4B/-, 4BKN/-, 4G/-, 4GKN/Size 4B 4G F (in) M10 10 deep 1 2" -13 UNC-2B 10 deep 4 G 33 38 Eg 3 200 300 400 500 600 690 1.0 Kp 0.8 0.6 0.5 High Speed Fuses Total Clearing I2t UL 5 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Electrical Characteristics The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1.4 1.2 103 9 8 7 6 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 80 90 100% For Other Voltage Ratings in This Body Style * See pages 154 (1000V) and 168 (1250V) 1mm = 0.0394" / 1" = 25.4mm 105 F O4 G 105 15 O56 53 67 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 135 High Speed Fuses Square Body Flush End Contact -- 690V (IEC): 1000-4000A Catalog Numbers Catalog -BKN/Type K Indicator for Micro 170M7078 170M7079 170M7080 170M7081 170M7082 170M7083 170M7084 170M7085 170M7086 -B/Visual Indicator 170M7058 170M7059 170M7060 170M7061 170M7062 170M7063 170M7064 170M7065 170M7066 Numbers -G/Visual Indicattor 170M7098 170M7099 170M7100 170M7101 170M7102 170M7103 170M7104 170M7105 170M7106 -GKN/Type K Indicator for Micro 170M7118 170M7119 170M7120 170M7121 170M7122 170M7123 170M7124 170M7125 170M7126 Electrical Characteristics Size 4 Rated Current RMS Norm. Liquid Cool. Cool. 1000 1350 1250 1700 1400 1900 1600 2200 2000 2700 2500 3400 3000 4100 3500 4700 4000 5400 I2t (A2 Sec) Clearing Pre-arc at 660V 76000 505000 145000 965000 205000 1400000 305000 2050000 600000 3950000 1200000 7800000 2000000 13500000 3250000 22000000 4700000 28000000 Watts Loss Norm. Liquid Cool. Cool. 175 315 195 355 205 375 220 405 245 445 275 495 305 555 325 585 355 640 Rated voltage (IEC) 500V. * Watts loss provided at rated current. * Liquid Cool. = Liquid cooling. Temperature on the terminals not to exceed 60C. * Microswitch indicator ordered separately. See accessories on pages 185-186. Size 4 -- 1000-4000A: 690V 1000A 1250A 1400A 1600A 2000A 2200A 2500A 3000A 3500A 4000A Time-Current Curve Peak Let-Through Curve 104 106 B Peak Let-Through Current 103 102 Virtual Pre-Arcing Time In Seconds A A 101 4000A 3500A 3000A 2500A 2200A 2000A 1600A 1400A 1250A 1000A 105 104 A 100 2x10 3 1x103 104 105 106 Prospective Short-Circuit Current Symmetrical RMS 10-1 4000A fuse is derated to 500V (IEC). 10-2 10-3 1x10-4 1x103 104 105 Prospective Current in Amps RMS 106 Data Sheet: 17056328 136 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 107 High Speed Fuses Square Body Flush End Contact Size 23, 24 -- 660V (IEC): 1000-7500A 660V (IEC) 1000-7500A Arc Voltage Electrical Characteristics Size 24 Size 23 This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg , (rms) at a power factor of 15%. Power Losses Total clearing I t 2 Size 23 Size 24 The total clearing I t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 2 Features and Benefits * Low watts loss * Superior cycling capability Size 24 Size 23 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. For Other Voltage Ratings in This Body Style * See pages 157 (1000V) and 171 (1250V) Typical Applications * Power converters/rectifiers * Reduced voltage starters For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 137 High Speed Fuses Specifications Description: High speed square body fuses, for the protection of the power rectifier section of the equipment. Dimensions: See dimensions illustration. Ratings: Volts: -- 660Vac Amps: -- 1000-4000A IR: -- 300kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. High Speed Fuses Square Body Flush End Contact Size 23, 24 -- 660V (IEC): 1000-7500A Fuse Size 23 -BU/55 Visual Indicator -BKE/55 Type K Indicator Catalogue Number -BKN/55 -GU/55 Type K Visual Indicator Indicator 170M6858 170M6859 170M6860 170M6861 170M6862 170M6863 170M6864 170M6865 170M6866 170M6867 170M6868 170M6869 170M6870 170M6898 170M6899 170M6900 170M6901 170M6902 170M6903 170M6904 170M6905 170M6906 170M6907 170M6908 170M6909 170M6910 170M6878 170M6879 170M6880 170M6881 170M6882 170M6883 170M6884 170M6885 170M6886 170M6887 170M6888 170M6889 170M6890 170M6918 170M6919 170M6920 170M6921 170M6922 170M6923 170M6924 170M6925 170M6926 170M6927 170M6928 170M6929 170M6930 Catalogue Number -BKN/60 -GU/60 Type K without Indicator Indicator -GKN/60 Type K Indicator 170M7158 170M7159 170M7160 170M7161 170M7162 170M7163 170M7164 170M7165 170M7166 170M7167 170M7168 170M7169 170M7218 170M7219 170M7220 170M7221 170M7222 170M7223 170M7224 170M7225 170M7226 170M7227 170M7228 170M7229 -GKE/55 Type K Indicator -GKN/55 Type K Indicator 170M6958 170M6959 170M6960 170M6961 170M6962 170M6963 170M6964 170M6965 170M6966 170M6967 170M6968 170M6969 170M6970 170M6938 170M6939 170M6940 170M6941 170M6942 170M6943 170M6944 170M6945 170M6946 170M6947 170M6948 170M6949 170M6950 Rated Voltage (V) 660 600 550 Electrical Characteristics 2 2 Rated I t (A Sec) Current Clearing RMS-Amp Pre-arc at 660V 1000 79,000 530,000 1100 95,000 635,000 1250 155,000 1,050,000 1400 200,000 1,350,000 1500 240,000 1,650,000 1600 315,000 2,150,000 1800 450,000 3,050,000 2000 625,000 4,200,000 2200 805,000 5,400,000 2500 1,250,000 8,350,000 3000 2,250,000 15,500,000 3500 3,450,000 21,000,000 4000 5,000,000 27,500,000 Watt Loss (W) 170.0 185.0 190.0 210.0 215.0 220.0 230.0 240.0 255.0 265.0 285.0 315.0 340.0 Data Sheet: 170K6326 Catalog Numbers: Fuse Size 24 -BU/60 without Indicator 170M7138 170M7139 170M7140 170M7141 170M7142 170M7143 170M7144 170M7145 170M7146 170M7147 170M7148 170M7149 170M7198 170M7199 170M7200 170M7201 170M7202 170M7203 170M7204 170M7205 170M7206 170M7207 170M7208 170M7209 Rated Voltage (V) 690 500 Electrical Characteristics 2 2 Rated I t (A Sec) Current Clearing at RMS-Amp Pre-arc 660V 2000 340000 2300000 2500 650000 4350000 3000 1100000 7300000 3500 1800000 12000000 4000 2700000 18000000 4500 3800000 25500000 5000 5450000 36500000 5500 7400000 49500000 6000 9600000 64000000 6500 12500000 83000000 7000 15000000 100000000 7500 18500000 93000000 Watts Loss (W) 340 390 430 460 490 520 540 560 580 600 630 660 A2s @ 500V Data Sheet: 170K6332 Size 24 Dimensions (mm): Type - BU/55, -BKE/55, -BKN/55, -GU/55, -GKE/55, -GKN/55 Size 23 Dimensions (mm): Type - BU/55, -BKE/55, -BKN/55, -GU/55, -GKE/55, -GKN/55 Size 23G 23B Size 24BKN A 2x3 M12 24GKN 2x3 1/2" 16UNC-2B 138 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa A 2x2 M10 / " 16UNC-2B 3 8 High Speed Fuses Square Body Flush End Contact Size 23, 24 -- 660V (IEC): 1000-7500A Size 23 -- 10000-4000A: 660V Size 24 -- 2000-7500A: 660V Time-Current Curve Time-Current Curve High Speed Fuses rospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request rospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 139 High Speed Fuses Square Body DIN 43 620 -- 690V (IEC): 10-800A Class gR -- Full Range Fuses 690V (IEC) 10-800A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg , (rms) at a power factor of 15%. Specifications Description: Square body DIN 43 620 blade style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 690Vac (IEC) Amps: -- 10-800A IR: -- 300kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. 1,5 Total clearing I t 1,0 2 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. K The total clearing I2t at rated voltage and at power 0,5 factor of 15% are given in 0,4 the electrical 0,3 characteristics. For other voltages, the clearing I2t is 0,2 found by multiplying by 200 300 400 500 correction factor, K, given as a function of applied working voltage, Eg, (rms). Eg 600 8 7 6 5 4 3 Eg 200 300 400 500 700 1,0 0,4 0,3 0,2 0,15 0,1 Ib 30 40 50 60 70 * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters * See page 132 Dimensions (mm) Type DIN 00, DIN 1, DIN 2, DIN 3 A 49 68 68 68 B Max 78.5 135 150 150 D Max 60 66 74 89 E 30 52 60 75 F Min 35 40 48 60 H 15 20 25 32 1 mm = 0.0394" 1" = 25.4 mm 140 700 Kp 0,8 0,7 0,6 0,5 For Operating Class aR Fuses in This Body Style Size 00 1 2 3 600 Power Losses Electrical Characteristics 3 UL 2,5 2 1,8 1,6 1,4 1,2 103 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 80 90 100% High Speed Fuses Square Body DIN 43 620 -- 690V (IEC): 10-800A Class gR -- Full Range Fuses Catalog Numbers Electrical Characteristics Size 00 1 2 3 RMS Amp Rating* 10 16 20 25 32 40 50 63 80 100 125 160 50 63 80 100 125 160 200 250 315 350 400 200 250 315 350 400 450 500 550 630 350 400 450 500 550 630 700 800 I2t (A2 Sec) Clearing Pre-arc at 600V 3.8 20 7.2 38 13 70 24 125 53 275 95 490 185 1000 345 1800 695 3600 1250 6650 2300 12000 4350 22500 135 705 245 1300 500 2600 950 4850 1850 9500 3450 18000 6750 34500 13500 70500 26000 135000 34000 175000 48500 250000 5650 29000 10000 52500 19500 105000 26000 135000 39500 205000 55500 290000 73000 375000 100000 515000 150000 770000 23000 120000 34000 175000 48500 250000 64000 330000 84500 435000 125000 645000 160000 840000 245000 1300000 Watts Loss 3.5 5.5 6 8 9 10 11 14 16 19 23 29 12 15 17 20 23 28 31 35 41 45 48 33 40 46 50 53 59 66 70 79 55 59 62 67 70 85 93 99 High Speed Fuses Catalog Numbers Type T Indicator For Micro 170M2691 170M2692 170M2693 170M2694 170M2695 170M2696 170M2697 170M2698 170M2699 170M2700 170M2701 170M2702 170M4176 170M4177 170M4178 170M4179 170M4180 170M4181 170M4182 170M4183 170M4184 170M4185 170M4186 170M5881 170M5882 170M5883 170M5884 170M5885 170M5886 170M5887 170M5888 170M5889 170M6080 170M6081 170M6082 170M6083 170M6084 170M6085 170M6086 170M6087 *The RMS amp rating of this fuse range is given with open fuse bases connected to copper conductors according to IEC 60269, Part 1, table 10. When used in enclosed fuse bases/ disconnects, derating factors have to be observed. Please contact Cooper Bussmann for application assistance. * Watts loss provided at rated current. * Microswitch ordered separately. See accessories on page 185-186. * For fuse curves see pages 142 and 143. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 141 High Speed Fuses Square Body Size 00, 1 -- 690V (IEC): 10-800A Class gR -- Full Range Fuses Size 1 -- 50-400A: 690V Time-Current Curve Time-Current Curve 104 103 103 102 102 10 1s 400A 315A 200A 103 10-4 5x101 104 102 103 104 5x104 Prospective Current In Amp RMS Peak Let-Through Curve Peak Let-Through Curve 105 160A 125A100A 80A 63A 50A 40A 32A 5A 2 20A 16A 10A 104 103 102 103 104 Prospective Short-Circuit Current Symmetrical RMS Amp 105 Peak Let-Through Current In Amperes 105 Peak Let-Through Current In Amperes 350A 250A 125A 102 Prospective Current In Amp RMS 142 160A 10-2 10-3 10-4 10 2x102 10 80A 10-3 10-1 50A 125A 80A 50A 32A 20A 10A 10-2 1s 100A 160A 100A 63A 40A 25A 10-1 10 63A Virtual Pre-arcing Time In Seconds 104 16A Virtual Pre-arcing Time In Seconds Size 00 -- 10-160A: 690V A 400A 350 315A250A 200A 160A 125A100A 104 80A 63A 50A 103 2x102 10 102 103 104 Prospective Short-Circuit Current Symmetrical RMS For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Amp 105 High Speed Fuses Square Body Size 2, 3 -- 690V (IEC): 10-800A Class gR -- Full Range Fuses Size 3 -- 350-800A: 690V Time-Current Curve Time-Current Curve 104 103 103 102 102 10 1s 10-1 700A 550A 450A 350A 630A 550A 500A 0A 45 400A 350A 315A 250A 10-1 10-2 10-2 10-3 10-3 10-4 102 103 104 105 10-4 102 Peak Let-Through Curve 104 105 Peak Let-Through Curve 105 105 630A 0A 550A 50 A A 00 0 1 45 5A 350A 31 250A 200A 104 103 103 104 105 Prospective Short-Circuit Current Symmetrical RMS Amp 106 Peak Let-Through Current In Amperes Peak Let-Through Current In Amperes 103 Prospective Current In Amp RMS Prospective Current In Amp RMS 2x102 102 High Speed Fuses 1s 10 800A 630A 500A 400A Virtual Pre-arcing Time In Seconds 104 200A Virtual Pre-arcing Time In Seconds Size 2 -- 200-630A: 690V 800A 0A 700A 63A 0 A 550 0 0A 450A 40 350A 104 103 2x102 102 103 104 105 Amp 106 Prospective Short-Circuit Current Symmetrical RMS For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 143 High Speed Fuses Square Body DIN 43 653 -- 1000V (IEC): 20-315A 1000V (IEC) 20-315A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg, (rms) at a power factor of 15%. Specifications Description: Square body DIN 43 653 stud-mount high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 1000Vac (20-250A) -- 900Vac (315A) Amps: -- 20-315A IR: -- 150kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. 1,5 The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multi-plying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 8 7 6 5 4 Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Electrical Characteristics Total clearing I2t 3 UL 2,5 2 1,8 1,6 1,4 1,2 103 K * 1,0 Eg 3 200 1,0 0,8 0,7 0,6 0,5 400 600 0,4 0,3 0,2 Eg 200 400 600 800 0,4 0,3 0,2 0,15 *Rated voltage 900V 30 40 50 60 70 Features and Benefits * Excellent DC performance * Low arc voltage and low energy let-through (I2t) * Low watts loss * Superior cycling capability 1000 * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters For Other Voltage Ratings in This Body Style Dimensions (mm) Type 00TN/80 - 00/80 Size 00/80 00TN/80 Max A 54 54 B 98 98 C 78 78 * See page 117 (690V/700V) D 51 51 Max E 30 30 F 28 28 G 67 H 10 10 1mm = 0.0394" / 1" = 25.4mm 144 1000 Kp 0,1 0,5 800 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Ib 80 90 100% High Speed Fuses Square Body DIN 43 653 -- 1000V (IEC): 20-315A * Watts loss provided at rated current. * Microswitch ordered separately. See accessories on page 185-186. Size 00 -- 20-315A: 1000V Time-Current Curve 104 103 102 10 High Speed Fuses Catalog Numbers Electrical Characteristics 00/80 00TN/80 I2t (A2 Sec) Visual Type T Rated Clearing Indicator for Indicator for Rated Current at Rated Watts Micro Micro Size Volttage RMS Amps Pre-arc Voltage Loss 170M4802 170M4822 1000 20 20 140 5 170M4803 170M4823 1000 25 30 210 7 170M4804 170M4824 1000 32 55 390 9 170M4805 170M4825 1000 35 69 500 10 170M4806 170M4826 1000 40 100 690 11 170M4807 170M4827 1000 50 170 1200 13 170M4808 170M4828 1000 63 280 2000 18 170M4809 170M4829 00 1000 80 500 3500 22 170M4810 170M4830 1000 100 950 6850 25 170M4811 170M4831 1000 125 1500 11500 33 170M4812 170M4832 1000 160 3000 22000 37 170M4813 170M4833 1000 200 5600 40500 40 170M4814 170M4834 1000 250 10000 74000 48 170M4815 170M4835 900 315 18000 115000 58 1s 10-1 315A * 200A 125A 80A 50A 35A 25A 250A 160A 100A 63A 40A 32A 20A Virtual Pre-arcing Time In Seconds Catalog Numbers 10-2 10-3 10-4 10 102 103 104 Prospective Current In Amp RMS Peak Let-Through Curve Peak Let-Through Current In Amperes 104 315A 250A 200A160A 125A 100A 80A 63A 50A 40A 35A 32A 25A 20A 103 102 2x10 10 102 103 104 Amp 105 Prospective Short-Circuit Prospective Short-Circuit Current Current symmetrical SymmetricalRMS RMS * 315A fuse is derated to 900V For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 145 High Speed Fuses Square Body DIN 43 653 -- 1000V (IEC): 50-1400A 1000V (IEC) 50-1400A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg, (rms) at a power factor of 15%. Specifications Description: Square body mount high speed fuses. Dimensions: See dimensions illustrations. Ratings: Volts: -- 1000Vac. Amps: -- 50-1400A IR: -- 150kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. 1,5 The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1,0 0,5 0,4 0,3 0,2 Eg 700 800 900 *Rated voltage 900V Dimensions (mm) Type -KN/110 Size 1*KN/110 1KN/110 2KN/110 3KN/110 A 80 80 80 81 B 138 138 138 139 C 108 108 108 108 Max D1 61 69 77 92 E 43 51 59 74 G 6 6 6 6 H 22 25 25 30 I 11 11 11 11 Max D2 61 69 75 90 E 43 51 59 74 G 6 6 6 6 H 22 25 25 30 I 11 11 11 11 Eg 3 1,0 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. * 600 4 1000 0,8 0,7 0,6 0,5 B C 138 108 138 108 138 108 139 108 / 1" = 25.4mm Type-KN/110 146 700 800 900 1000 Kp 0,4 0,3 0,2 0,15 0,1 30 Ib 40 50 60 70 * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 80 90 100% For Other Voltage Ratings in This Body Style * See pages 122 (690V/700V) and 160 (1250V/1300V) Type -TN/110 Size A 1*TN/110 80 1TN/110 80 2TN/110 80 3TN/110 81 1mm = 0.0394" 600 Power Losses K 500 8 7 6 5 500 Electrical Characteristics Total clearing I2t 3 UL 2,5 2 1,8 1,6 1,4 1,2 103 Type-TN/110 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body DIN 43 653 -- 1000V (IEC): 50-1400A Catalog Numbers Size 1* 1 2 3 Rated Voltag ge 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 900 Electrical Characteristics Rated I2t (A2 Sec) Current Clearing RMS at Rated Amps Pre-arc Voltage 50 135 815 63 215 1300 80 460 2750 100 860 5100 125 1450 8600 160 2850 17500 200 4950 29500 250 9550 57000 315 21500 130000 350 29000 175000 400 42000 250000 160 2200 13500 200 4150 24500 250 7750 46000 315 16500 98500 350 21500 130000 400 31000 185000 450 44500 265000 500 63000 375000 550 84500 500000 630 125000 755000 250 6750 40000 315 13500 81500 350 16500 99000 400 26000 155000 450 35500 210000 500 49500 295000 550 66000 390000 630 93500 555000 700 130000 770000 800 195000 1200000 315 9200 54500 350 13000 77500 400 19000 115000 450 27000 160000 500 37500 225000 550 52000 310000 630 82500 490000 700 115000 700000 800 170000 1050000 900 250000 1500000 1000 340000 2050000 1100 460000 2750000 1250 575000 3400000 1400 795000 4200000 Watts Loss 20 25 30 35 40 45 48 50 60 65 70 40 45 52 60 65 70 80 85 90 98 65 75 80 85 90 95 100 110 115 125 90 95 105 107 110 115 120 125 135 145 150 155 175 185 High Speed Fuses Catalog Numbers -KN/110 -TN/110 Type K Type T Indicator for Indicator for Micro Micro 170M3965 170M3981 170M3966 170M3982 170M3967 170M3983 170M3968 170M3984 170M3969 170M3985 170M3970 170M3986 170M3971 170M3987 170M3972 170M3988 170M3973 170M3989 170M3974 170M3990 170M3975 170M3991 170M4965 170M4980 170M4966 170M4981 170M4967 170M4982 170M4968 170M4983 170M4969 170M4984 170M4970 170M4985 170M4971 170M4986 170M4972 170M4987 170M4973 170M4988 170M4974 170M4989 170M5966 170M5981 170M5967 170M5982 170M5968 170M5983 170M5969 170M5984 170M5970 170M5985 170M5971 170M5986 170M5972 170M5987 170M5973 170M5988 170M5974 170M5989 170M5975 170M5990 170M8614 170M8629 170M8615 170M8630 170M8616 170M8631 170M8617 170M8632 170M8618 170M8633 170M8619 170M8634 170M8620 170M8635 170M8621 170M8636 170M8622 170M8637 170M8623 170M8638 170M8624 170M8639 170M8625 170M8640 170M8626 170M8641 170M8627 170M8642 * Watts loss provided at rated current. * Microswitch ordered separately. See accessories on page 185-186. * For fuse curves see pages 152 and 153. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 147 High Speed Fuses Square Body Flush End Contact -- 1000V (IEC): 50-1400A 1000V (IEC) 50-1400A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg, (rms) at a power factor of 15%. Specifications Description: Square body flush end contact high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 1000Vac. Amps: -- 50-1400A IR: -- 150kA (Est. 300kA) RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. 1,5 The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. K * 1,0 0,5 0,4 0,3 0,2 Eg 500 600 700 800 900 8 7 6 5 4 Eg 3 Power Losses Electrical Characteristics Total clearing I2t 3 UL 2,5 2 1,8 1,6 1,4 1,2 103 1000 500 1,0 0,8 0,7 0,6 0,5 600 700 800 0,4 0,3 0,2 0,15 0,1 30 Ib 40 50 60 70 Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 80 90 100% For Other Voltage Ratings in This Body Style * See pages 124 (690V/700V) and 162 (1250V/1300V) Dimensions (mm) Type -BKN/- and -GKN/Size A B 1*BKN/75+GKN/75 72.5 74 1BKN/75+GKN/75 73.2 74 2BKN/75+GKN/75 73.2 74.4 3BKN/75+GKN/75 73.3 75.4 3BKN/90+GKN/90 80.3 91.4 * Valid for fuses type -GKN/-. 1mm = 0.0394" / 1" = 25.4mm 148 Max D 61 69 77 92 92 E 43 52 59 74 74 F M8 M8 M10 M12 M12 F* (in) 16" - 18 UNC-2B 16" - 18 UNC-2B 3 8" - 16 UNC-2B 1 2" - 13 UNC-2B 1 2" - 13 UNC-2B 5 5 Min G 5 8 10 10 10 1000 Kp * * * * *Rated voltage 900V 900 H o17.5 o20 o24 o30 o30 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body Flush End Contact -- 1000V (IEC): 50-1400A Catalog Numbers Rated Volttage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 900 Electrical Characteristics I2t (A2 Sec) Rated Clearing Current at Rated Voltage RMS-Amps Pre-arc 50 135 815 63 215 1300 80 460 2750 100 860 5100 125 1450 8600 160 2850 17500 200 4950 29500 250 9550 57000 315 21500 130000 350 29000 175000 400 42000 250000 160 2200 13500 200 4150 24500 250 7750 46000 315 16500 98500 350 21500 130000 400 31000 185000 450 44500 265000 500 63000 375000 550 84500 500000 630 125000 755000 250 6750 40000 315 13500 81500 350 16500 99000 400 26000 155000 450 35500 210000 500 49500 295000 550 66000 390000 630 93500 555000 700 130000 770000 800 195000 1200000 315 9200 54500 350 13000 77500 400 19000 115000 450 27000 160000 500 37500 225000 550 52000 310000 630 82500 490000 700 115000 700000 800 170000 1050000 900 250000 1500000 1000 340000 2050000 1100 460000 2750000 1250 575000 3400000 1400 795000 4200000 Watts Loss 20 25 30 35 40 45 48 50 60 65 70 40 45 52 60 65 70 80 85 90 98 65 75 80 85 90 95 100 110 115 125 90 95 105 107 110 115 120 125 135 145 150 155 175 185 High Speed Fuses Catalog Numbers -BKN/-GKN/Type K Type K Indicator for Indicator for Micro Micro Size 170M3951 170M3921 170M3952 170M3922 170M3953 170M3923 170M3954 170M3924 170M3955 170M3925 170M3956 170M3926 1* 170M3957 170M3927 170M3958 170M3928 170M3959 170M3929 170M3960 170M3930 170M3961 170M3931 170M4951 170M4921 170M4952 170M4922 170M4953 170M4923 170M4954 170M4924 170M4955 170M4925 1 170M4956 170M4926 170M4957 170M4927 170M4958 170M4928 170M4959 170M4929 170M4960 170M4930 170M5952 170M5922 170M5953 170M5923 170M5954 170M5924 170M5955 170M5925 170M5956 170M5926 170M5957 170M5927 2 170M5958 170M5928 170M5959 170M5929 170M5960 170M5930 170M5961 170M5931 170M8600 170M8500 170M8601 170M8501 170M8602 170M8502 170M8603 170M8503 170M8604 170M8504 170M8605 170M8505 170M8606 170M8506 3 170M8607 170M8507 170M8608 170M8508 170M8609 170M8509 170M8610 170M8510 170M8611 170M8511 170M8612** 170M8512** 170M8613** 170M8513** **Overall length is 90mm, for all other fuses the overall length is 75mm. * Watts loss provided at rated current. * Microswitch ordered separately. See accessories on page 185-186. * For fuse curves see pages 152 and 153. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 149 High Speed Fuses Square Body US style -- 1000V (IEC): 50-1400A 1000V (IEC) 50-1400A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg, (rms) at a power factor of 15%. Specifications Description: Square body US style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 1000Vac. Amps: -- 50-1400A IR: -- 150kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. 1,5 The total clearing I t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. K 2 * 1,0 0,5 0,4 0,3 0,2 Eg 500 600 700 800 900 1000 Size 1*FKE/115 1FKE/115 2FKE/115 3FKE/115 B 156 160 160 159 C1 130 127 127 128 Eg 3 500 1,0 0,8 0,7 0,6 0,5 700 800 900 0,4 0,3 0,2 0,15 0,1 30 Ib 40 50 60 70 Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 80 For Other Voltage Ratings in This Body Style C2 101 102 102 101 D 59 69 77 92 E 45 53 61 76 H 20 25 25 36 I 10 14 14 16 1000 Kp * See pages 126 (690V/700V) and 164 (1250V/1300) 1mm = 0.0394" / 1" = 25.4mm 150 600 * * * * *Rated voltage 900V Dimensions (mm) Type -FKE/115 8 7 6 5 4 Power Losses Electrical Characteristics Total clearing I2t 3 UL 2,5 2 1,8 1,6 1,4 1,2 103 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 90 100% High Speed Fuses Square Body US style -- 1000V (IEC): 50-1400A Catalog Numbers Electrical Characteristics Size 1* 1 2 3 Rated Current RMS-Amps 50 63 80 100 125 160 200 250 315 350 400 160 200 250 315 350 400 450 500 550 630 250 315 350 400 450 500 550 630 700 800 315 350 400 450 500 550 630 700 800 900 1000 1100 1250 1400 I2t (A2 Sec) Clearing Pre-arc at 1000V 135 815 215 1300 460 2750 860 5100 1450 8600 2850 17500 4950 29500 9550 57000 21500 130000 29000 175000 42000 250000 2200 13500 4150 24500 7750 46000 16500 98500 21500 130000 31000 185000 44500 265000 63000 375000 84500 500000 125000 755000 6750 40000 13500 81500 16500 99000 26000 155000 35500 210000 49500 295000 66000 390000 93500 555000 130000 770000 195000 1200000 9200 54500 13000 77500 19000 115000 27000 160000 37500 225000 52000 310000 82500 490000 115000 700000 170000 1050000 250000 1500000 340000 2050000 460000 2750000 575000 3400000 795000 4200000* Watts Loss 20 25 30 35 40 45 48 50 60 65 70 40 45 52 60 65 70 80 85 90 98 65 75 80 85 90 95 100 110 115 125 90 95 105 107 110 115 120 125 135 145 150 155 175 185 High Speed Fuses Catalog Numbers -FKE/115 Type K Indicator for Micro 170M3531 170M3532 170M3533 170M3534 170M3535 170M3536 170M3537 170M3538 170M3539 170M3540 170M3541 170M4531 170M4532 170M4533 170M4534 170M4535 170M4536 170M4537 170M4538 170M4539 170M4540 170M5531 170M5532 170M5533 170M5534 170M5535 170M5536 170M5537 170M5538 170M5539 170M5540 170M8531 170M8532 170M8533 170M8534 170M8535 170M8536 170M8537 170M8538 170M8539 170M8540 170M8541 170M8542 170M8543 170M8544* * Rated voltage 900V. * Watts loss provided at rated current. * Microswitch ordered separately. See accessories on pages 185-186. * For fuse curves see pages 152 and 153. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 151 High Speed Fuses Square Body Size 1*, 1 -- 1000V (IEC): 50-1400A Size 1* -- 50-400A: 1000V Size 1 -- 160-630A: 1000V Time-Current Curve Time-Current Curve 104 103 10-2 10-3 102 103 104 5x104 10-4 102 Prospective Current In Amp RMS 105 105 400A A 350A 315 250A 200A 160A 125A 100A 80A 630A 50A 104 103 103 104 105 Prospective Short-Circuit Current Symmetrical RMS Amp 106 Peak Let-Through Current In Amperes Peak Let-Through Current In Amperes 104 Peak Let-Through Curve 105 152 103 Prospective Current In Amp RMS Peak Let-Through Curve 2x102 102 550A 450A 350A 10-4 5x101 250A 10-3 10-1 160A 350A 250A 160A 100A 63A 10-2 1s 630A 500A 400A 315A 400A 315A 200A 125A 80A 10-1 10 200A Virtual Pre-arcing Time In Seconds 1s 50A Virtual Pre-arcing Time In Seconds 102 630A 550A A 500A 450 0A 400A 35 315A 50A 2 200A 160A 104 103 2x102 102 103 104 105 Prospective Short-Circuit Current Symmetrical RMS For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Amp 106 High Speed Fuses Square Body Size 2, 3 -- 1000V (IEC): 50-1400A Size 2 -- 250-800A: 1000V Size 3 -- 315-1400A: 1000V Time-Current Curve Time-Current Curve 104 104 103 103 10 250A 10-1 800A 630A 500A 400A 315A 10-2 10-3 1s 10-1 10-2 10-3 10-4 102 103 104 105 10-4 102 Prospective Current In Amp RMS 104 105 Peak Let-Through Curve 105 105 800A 630A 500A 400A 315A 700A 550A 450A 350A 250A 104 103 103 104 105 Prospective Short-Circuit Current Symmetrical RMS Amp 106 Peak Let-Through Current In Amperes Peak Let-Through Current In Amperes 103 Prospective Current In Amp RMS Peak Let-Through Curve 2x102 102 High Speed Fuses 1s 10 * 1400A 1250A 1100A 1000A 900A 800A 700A 630A 550A 500A 450A 400A 350A 315A Virtual Pre-arcing Time In Seconds 102 700A 550A 450A 350A Virtual Pre-arcing Time In Seconds 102 *11205000AA A 1400 A 1100 900A A 700 550A 450A 350A 800A 630A 500A 400A 315A 104 103 2x102 102 103 104 105 Amp 106 Prospective Short-Circuit Current Symmetrical RMS * 1400A fuses are derated to 900V For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 153 High Speed Fuses Square Body Flush End Contact Size 4 -- 1000V (IEC): 1000-2700A 1000V (IEC) 1000-2700A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg , (rms) at a power factor of 15%. Specifications Description: Square body DIN 43 620 blade style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 1000Vac (IEC) Amps: -- 1000-2700A IR: -- 125kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Electrical Characteristics Total clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters For Other Voltage Ratings in This Body Style * See pages 135 (690V/700V) and 168 (1250V) Catalog Numbers Fuse Size 4 154 Catalog Number -SBKN/90 -BKN/95 Type K Type K Indicator Indicator 170M7636 170M7639 170M7963 170M7090 170M7640 170M7658 170M7542 170M7031 170M7548 170M7034 170M7544 170M7035 170M7036 170M7037 Rated Voltage (V) 1000 Electrical Characteristics 2 2 Rated I t (A Sec) Current Clearing RMS-Amp Pre-arc at 1000V 1000 180000 1100000 1100 250000 1500000 1500 600000 3600000 1700 850000 5000000 2000 1450000 8600000 2200 2000000 12000000 2500 3000000 18000000 2700 3700000 22000000 Watt Loss (W) 195 200 250 260 270 280 295 310 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body Flush End Contact Size 4 -- 1000V (IEC): 1000-2700A Flush End Contact - Size 4 1000V : 1000 - 2700A Dimensions (mm): Type 4BKN/95 High Speed Fuses Type 4SBKN/95 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 155 High Speed Fuses Square Body Flush End Contact Size 4 -- 1000V (IEC): 1000-2700A Size 4 -- 1000-2700A: 660V Time-Current Curve Prospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request 156 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body Flush End Contact Size 24 -- 1000V (IEC): 2000-5000A 1000V (IEC) 2000-5000A Arc Voltage Electrical Characteristics 4200-5000A 2000-3500A This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg , (rms) at a power factor of 15%. Power Losses Total clearing I t 2 2000-3500A 4200-5000A The total clearing I t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 2 Features and Benefits * Low watts loss * Superior cycling capability 4200-5000A 2000-3500A Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. For Other Voltage Ratings in This Body Style * See pages 137 (660V) and 171 (1250V) Typical Applications * Power converters/rectifiers * Reduced voltage starters For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 157 High Speed Fuses Specifications Description: High speed square body fuses, for the protection of the power rectifier section of the equipment. Dimensions: See dimensions illustration. Ratings: Volts: -- 1000Vac Amps: -- 2000-5000A IR: -- 300kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. High Speed Fuses Square Body Flush End Contact Size 24 -- 1000V (IEC): 2000-5000A Catalog Numbers Cat. Number Rated -BKN/85 Fuse Voltage Type K Size (V) Indicator 24 170M7608 170M7680 170M7567 170M7568 170M7569 170M7498 170M7488 170M7622 1000 Electrical Characteristics 2 2 Rated I t (A Sec) Current Clearing at RMS-Amp Pre-arc 1000V 2000 3000 3200 3500 4000 4200 4500 5000 885000 2900000 3300000 4500000 6800000 8000000 10000000 14000000 5700000 19000000 20000000 27000000 40000000 47500000 59000000 82500000 Watt Loss (W) 345 430 440 450 475 485 495 540 Data Sheet: 170K7540, 170K8514 Dimensions (mm): 158 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body Flush End Contact Size 24 -- 1000V (IEC): 2000-5000A Size 24 -- 2000-3500A: 1000V Size 24 -- 4200-5000A: 1000V Time-Current Curve Time-Current Curve High Speed Fuses Prospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request Prospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 159 High Speed Fuses Square Body DIN 43 653 -- 1250V/1300V (IEC/UL): 50-1400A 1250V/1300V (IEC/UL) 50-1400A Arc Voltage This curve gives the peak 1.8 arc voltage, UL, which 1.4 may appear across the fuse during its operation 103 8 as a function of the applied working voltage, 6 Eg, (rms) at a power factor 5 4 of 15%. Specifications Description: Square body DIN 43 653 stud-mount high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 1250Vac (IEC) -- 1300Vac (UL) Amps: -- 50-1400A IR: -- 100kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. Consult Cooper Bussmann for UL Recognition/CSA Component Acceptance status. Total Clearing I t The total clearing I2t at rated voltage and at power factor of 15% are 0.5 given in the electrical 0.4 characteristics. For other 0.3 2 voltages, the clearing I t is found by multiplying by 0.2 Eg correction factor, K, 400 600 800 1000 1200 1400 given as a function of applied working voltage, Dashed lines (- - - - - -) apply to the following amperages:. Eg, (rms). Size Amps. 1* 1 2 3 400 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. 1.5 K 1.25 1.0 400A 500-630A 630-1000A 800-1400A UL Eg 3 Power Losses Electrical Characteristics 2 3 2.5 600 800 1000 1200 1400 1.0 Kp 0.8 0.6 0.5 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 80 90 100% For Other Voltage Ratings in This Body Style * See pages 122 (690V/700V) and 146 (1000V) Dimensions (mm) Type -KN/110 Dimensions (mm) Size 1* 1 2 3 Type -/110, -TN/110 Size 1* 1 2 3 A 80 80 80 81 B 138 138 138 139 D** 58 66 75 90 E 45 53 61 76 H 20 25 25 30 108 A A 80 80 80 81 B 138 138 138 139 D 58 66 75 90 E 45 53 61 76 H 20 25 25 30 1mm = 0.0394" / 1" = 25.4mm C **Microswitch. 1mm = 0.0394" / 1" = 25.4mm A H 11 H D E B 11 D 6 B E E 6 E 160 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body DIN 43 653 -- 1250V/1300V (IEC/UL): 50-1400A Catalog Numbers -KN/110 Type K Indicator for Micro 170M3238 170M3239 170M3240 170M3241 170M3242 170M3243 170M3244 170M3245 170M3246 170M3247 170M3248 170M4238 170M4239 170M4240 170M4241 170M4242 170M4243 170M4244 170M4245 170M4246 170M4247 170M5238 170M5239 170M5240 170M5241 170M5242 170M5243 170M5244 170M5245 170M5246 170M5247 170M5248 170M5249 170M5250 170M6238 170M6239 170M6240 170M6241 170M6242 170M6243 170M6244 170M6245 170M6246 170M6247 170M6248 170M6249 170M6250 170M6251 Size 1* 1 2 3 Rated Current RMS-Amps 50 63 80 100 125 160 200 250 315 350 400 160 200 250 315 350 400 450 500 550 630 250 280 315 350 400 450 500 550 630 700 800 900 1000 315 350 400 450 500 550 630 700 800 900 1000 1100 1250 1400 Electrical Characteristics I2t (A2 Sec) Clearing Clearing Pre--arc at 1000V at 1250V 135 815 1100 215 1300 1750 420 2500 3350 750 4450 5950 1450 9000 11500 2600 16000 21000 5150 31000 41000 9200 54500 73000 18500 115000 150000 27000 165000 220000 53000 265000 335000 1900 11500 15500 3800 22500 30000 7750 46000 61500 15000 90000 120000 20000 125000 165000 29500 175000 235000 42000 250000 335000 69500 340000 435000 95000 465000 590000 130000 660000 6500 38500 51500 9350 55500 74500 13000 77500 105000 16500 97500 135000 23000 140000 180000 34000 205000 270000 48000 285000 380000 62000 370000 495000 115000 575000 730000 160000 795000 1050000 245000 1200000 1550000 360000 1750000 480000 2350000 9500 58000 77500 13500 81500 110000 19500 120000 160000 31000 185000 245000 39000 235000 310000 55000 325000 435000 83500 495000 665000 115000 705000 940000 205000 995000 1300000 305000 1500000 1900000 450000 2150000 2750000 575000 2800000 3600000 810000 3950000 1250000 6000000 Watts Loss 15 20 25 30 35 40 45 55 60 65 70 45 50 60 65 70 75 80 85 95 100 65 70 75 80 85 90 95 100 110 115 120 125 135 85 90 95 100 105 110 115 120 125 130 135 140 145 150 High Speed Fuses Catalog Numbers -TN/110 -/110 Type T Visual Indicator Indicator for Micro 170M3138 170M3188 170M3139 170M3189 170M3140 170M3190 170M3141 170M3191 170M3142 170M3192 170M3143 170M3193 170M3144 170M3194 170M3145 170M3195 170M3146 170M3196 170M3147 170M3197 170M3148 170M3198 170M4138 170M4188 170M4139 170M4189 170M4140 170M4190 170M4141 170M4191 170M4142 170M4192 170M4143 170M4193 170M4144 170M4194 170M4145 170M4195 170M4146 170M4196 170M4147 170M4197 170M5138 170M5188 170M5139 170M5189 170M5140 170M5190 170M5141 170M5191 170M5142 170M5192 170M5143 170M5193 170M5144 170M5194 170M5145 170M5195 170M5146 170M5196 170M5147 170M5197 170M5148 170M5198 170M5149 170M5199 170M5150 170M5200 170M6138 170M6188 170M6139 170M6189 170M6140 170M6190 170M6141 170M6191 170M6142 170M6192 170M6143 170M6193 170M6144 170M6194 170M6145 170M6195 170M6146 170M6196 170M6147 170M6197 170M6148 170M6198 170M6149 170M6199 170M6150 170M6200 170M6151 170M6201 Rated voltage (IEC) 1100V. Rated voltage (IEC) 1250V. * Watts loss provided at rated current. * Microswitch indicator ordered separately. See accessories on pages 185-186. * For fuse curves see pages 166 and 167. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 161 High Speed Fuses Square Body Flush End Contact -- 1250V/1300V (IEC/UL): 50-1400A 1250V/1300V (IEC/UL) 50-1400A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: Square body flush end contact high speed fuses. Dimensions: See dimensions illustrations. Ratings: Volts: -- 1250Vac (IEC) -- 1300Vac (UL) Amps: -- 50-1400A IR: -- 100kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. Consult Cooper Bussmann for UL Recognition/CSA Component Acceptance status. The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1.5 K 1.25 1.0 0.5 0.4 0.3 0.2 1.4 103 8 6 5 4 Eg Type BKN + GKN/75 BKN/80 BKN + GKN/75 BKN/80 BKN + GKN/75 BKN/80 BKN + GKN/90 BKN + GKN/75 BKN/80 BKN + GKN/90 A 74 80 74 80 74 80 80 74 81 81 **Valid for fuses type -GKN/-. 1mm = 0.0394" / 1" = 25.4mm B 75 81 75 81 75 81 91 76 83 91 D 59 59 69 69 77 77 77 92 92 92 E 45 45 53 53 61 61 61 76 76 76 F M8 M8 M8 M8 M10 M10 M10 M12 M12 M12 F** (in) 16" - 18 UNC-2B 5 16" - 18 UNC-2B 5 8" - 16 UNC-2B 3 8" - 16 UNC-2B 2" - 13 UNC-2B 3 1 2" - 13 UNC-2B 1 G 5 5 8 8 10 10 10 10 10 10 1000 1200 1400 0.6 0.5 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters For Other Voltage Ratings in This Body Style * See pages 124 (690V/700V) and 148 (1000V) H O17 O17 O20 O20 O24 O24 O24 O30 O30 O30 B D A E F E H G 162 800 1.0 Kp 0.8 Dimensions (mm) Type -BKN/-, -GKN/Size 1* 1* 1 1 2 2 2 3 3 3 600 * * * * Eg 400 600 800 1000 1200 1400 Dashed lines (- - - - - -) apply to the following amperages:. Size Amps. 1* 400A 1 500-630A 2 630-1000A 3 800-1400A 1.8 400 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Total Clearing I2t UL 3 Power Losses Electrical Characteristics 3 2.5 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 80 90 100% High Speed Fuses Square Body Flush End Contact -- 1250V/1300V (IEC/UL): 50-1400A Catalog Numbers 170M6338 170M6339 170M6340 170M6341 170M6342 170M6343 170M6344 170M6345 170M6346 170M6347 170M6348 170M6349 170M6538 170M6539 170M6540 170M6541 170M6542 170M6543 170M6544 170M6545 170M6546 170M6547 170M6548 170M6549 -BKN/90 Type K Indicator for Mic cro 170M5494 170M5495 170M5496 170M5497 170M5498 170M5499 170M5500 170M6494 170M6495 170M6496 170M6497 170M6498 170M6499 170M6500 170M6501 -GKN/75 Type K Indicator for Micro 170M3488 170M3489 170M3490 170M3491 170M3492 170M3493 170M3494 170M3495 170M3496 170M3497 170M4488 170M4489 170M4490 170M4491 170M4492 170M4493 170M4494 170M4495 170M4496 170M4497 170M5588 170M5589 170M5590 170M5591 170M5592 170M5593 170M5594 170M5595 170M5596 170M5597 170M5598 170M6588 170M6589 170M6590 170M6591 170M6592 170M6593 170M6594 170M6595 170M6596 170M6597 170M6598 170M6599 -GKN/90 Type K Indicator for Micro 170M5644 170M5645 170M5646 170M5647 170M5648 170M5649 170M5650 170M6644 170M6645 170M6646 170M6647 170M6648 170M6649 170M6650 170M6651 Electrical Characteristics Rated Current I2t (A2Sec) RMSClearing Clearing Size Amps Pre-arc at 1000V at 1250V 50 135 815 1100 63 215 1300 1750 80 420 2500 3350 100 750 4450 5950 125 1450 9000 11500 1* 160 2600 16000 21000 200 5150 31000 41000 250 9200 54500 73000 315 18500 115000 150000 350 27000 165000 220000 400 53000 265000 335000 160 1900 11500 15500 200 3800 22500 30000 250 7750 46000 61500 315 15000 90000 120000 350 20000 125000 165000 1 400 29500 175000 235000 450 42000 250000 335000 500 69500 340000 435000 550 95000 465000 590000 630 130000 660000 250 6500 38500 51500 280 9350 55500 74500 315 13000 77500 105000 350 16500 97500 135000 400 23000 140000 180000 450 34000 205000 270000 2 500 48000 285000 380000 550 62000 370000 495000 630 115000 575000 730000 700 160000 795000 1050000 800 245000 1200000 1550000 900 360000 1750000 1000 480000 2350000 315 9500 58000 77500 350 13500 81500 110000 400 19500 120000 160000 450 31000 185000 245000 500 39000 235000 310000 550 55000 325000 435000 630 83500 495000 665000 3 700 115000 705000 940000 800 205000 995000 1300000 900 305000 1500000 1900000 1000 450000 2150000 2750000 1100 575000 2800000 3600000 1250 810000 3950000 1400 1250000 6000000 Watts Loss 15 20 25 30 35 40 45 55 60 65 70 45 50 60 65 70 75 80 85 95 100 65 70 75 80 85 90 95 100 110 115 120 125 135 85 90 95 100 105 110 115 120 125 130 135 140 145 150 High Speed Fuses Catalog Numbers -BKN/75 -BKN/80 Type K Type K Indicator Indicator for Micro for Micro 170M3388 170M3438 170M3389 170M3439 170M3390 170M3440 170M3391 170M3441 170M3392 170M3442 170M3393 170M3443 170M3394 170M3444 170M3395 170M3445 170M3396 170M3446 170M3397 170M3447 170M3448 170M4388 170M4438 170M4389 170M4439 170M4390 170M4440 170M4391 170M4441 170M4392 170M4442 170M4393 170M4443 170M4394 170M4444 170M4395 170M4445 170M4396 170M4446 170M4397 170M4447 170M5388 170M5438 170M5389 170M5439 170M5390 170M5440 170M5391 170M5441 170M5392 170M5442 170M5393 170M5443 170M5394 170M5444 170M5395 170M5445 170M5396 170M5446 170M5397 170M5447 170M5398 170M5448 Rated voltage (IEC) 1100V. Rated voltage (IEC) 1000V. Rated voltage (IEC) 1250V. * Watts loss provided at rated current. * Microswitch indicator ordered separately. See accessories on pages 185-186. * For fuse curves see pages 166 and 167. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 163 High Speed Fuses Square Body US Style -- 1250V/1300V (IEC/UL): 50-1400A 1250V/1300V (IEC/UL) 50-1400A Arc Voltage Specifications Description: Square body US style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 1250Vac (IEC) -- 1300Vac (UL) Amps: -- 50-1400A IR: -- 100kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. Consult Cooper Bussmann for UL Recognition/CSA Component Acceptance status. Characteristics Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Total Clearing I2t 0.5 The total clearing I2t at 0.4 rated voltage and at power factor of 15% are given in 0.3 the electrical 0.2 Eg characteristics. For other voltages, the clearing I2t is 400 600 800 1000 1200 1400 Dashed lines (- - - - - -) apply to the found by multiplying by correction factor, K, given as following amperages:. Size Amps. a function of applied working 1* 400A 1 500-630A voltage, Eg, (rms). 2 3 630-1000A 800-1400A B 156 160 160 159 C1 130 127 127 128 C2 101 102 102 101 400 0.4 0.3 0.2 Ib 0.1 30 40 50 70 Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters * See pages 126 (690V/700V) and 150 (1000V) D 59 69 77 92 E 45 53 61 76 H 20 25 25 36 I 10 14 14 16 A 164 60 * * * * 6 C1 C2 E 1000 1200 1400 0.6 0.5 B E 800 1.0 Kp 0.8 1mm = 0.0394" / 1" = 25.4mm D Eg 600 For Other Voltage Ratings in This Body Style Dimensions (mm) Type -FU/115, -FKE/115 Size 1* 1 2 3 UL 3 Power Losses 1.5 K 1.25 1.0 Electrical 3 2.5 This curve gives the peak 1.8 arc voltage, UL, which 1.4 may appear across the fuse during its operation 103 8 as a function of the applied working voltage, 6 Eg, (rms) at a power factor 5 4 of 15%. I H For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 80 90 100% High Speed Fuses Square Body US Style -- 1250V/1300V (IEC/UL): 50-1400A Catalog Numbers Electrical Characteristics Size 1* 1 2 3 Rated Current RMS-Amps Pre-arc 50 135 63 215 80 420 100 750 125 1450 160 2600 200 5150 250 9200 315 18500 350 27000 160 1900 200 3800 250 7750 315 15000 350 20000 400 29500 450 42000 500 69500 550 95000 630 130000 250 6500 280 9350 315 13000 350 16500 400 23000 450 34000 500 48000 550 62000 630 115000 700 160000 800 245000 900 360000 1000 480000 315 9500 350 13500 400 19500 450 31000 500 39000 550 55000 630 83500 700 115000 800 205000 900 305000 1000 450000 1100 575000 1250 810000 1400 1250000 I2t (A2 Sec) Clearing Clearing at 1000V at 125 50V 815 1100 1300 1750 2500 3350 4450 5950 9000 11500 16000 21000 31000 41000 54500 73000 115000 150000 165000 220000 11500 15500 22500 30000 46000 61500 90000 120000 125000 165000 175000 235000 250000 335000 340000 465000 660000 38500 51500 55500 74500 77500 105000 97500 135000 140000 180000 205000 270000 285000 380000 370000 495000 575000 730000 795000 1200000 1750000 2350000 58000 77500 81500 110000 120000 160000 185000 245000 235000 310000 325000 435000 495000 665000 705000 940000 995000 1300000 1500000 1900000 2150000 2800000 3950000 6000000 Watts Loss 15 20 25 30 35 40 45 55 60 65 45 50 60 65 70 75 80 85 95 100 65 70 75 80 85 90 95 100 110 115 120 125 135 185 90 95 100 105 110 115 120 125 130 135 140 145 150 High Speed Fuses Catalog Numbers -FKE/115 -FU/115 Type K Without Indicator Indicator for Micro 170M3688 170M3738 170M3689 170M3739 170M3690 170M3740 170M3691 170M3741 170M3692 170M3742 170M3693 170M3743 170M3694 170M3744 170M3695 170M3745 170M3696 170M3746 170M3697 170M3747 170M4688 170M4738 170M4689 170M4739 170M4690 170M4740 170M4691 170M4741 170M4692 170M4742 170M4693 170M4743 170M4694 170M4744 170M4695 170M4745 170M4696 170M4746 170M4697 170M4747 170M5688 170M5738 170M5689 170M5739 170M5690 170M5740 170M5691 170M5741 170M5692 170M5742 170M5693 170M5743 170M5694 170M5744 170M5695 170M5745 170M5696 170M5746 170M5697 170M5747 170M5698 170M5748 170M5699 170M5749 170M5700 170M5750 170M6688 170M6738 170M6689 170M6739 170M6690 170M6740 170M6691 170M6741 170M6692 170M6742 170M6693 170M6743 170M6694 170M6744 170M6695 170M6745 170M6696 170M6746 170M6697 170M6747 170M6698 170M6748 170M6699 170M6749 170M6700 170M6750 170M6701 170M6751 Rated voltage (IEC) 1100. Rated voltage (IEC) 1000V. UL Recognition at 1000V. * Watts loss provided at rated current. * Microswitch indicator ordered separately. See accessories on pages 185-186. * For fuse curves see pages 166 and 167. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 165 High Speed Fuses Square Body Size 1*, 1 -- 1250V/1300V (IEC/UL): 50-1400A Size 1 -- 160-630A: 1250V Time-Current Curve Time-Current Curve 160A 200A 250A 315A 350A 400A 450A 500A 550A 630A Size 1* -- 50-400A:1250V 104 103 102 Virtual Pre-Arcing Time In Seconds A A 101 100 10-1 10-2 10-3 1x10-4 103 104 Prospective Current In Amp RMS 105 105 B 104 103 Peak Let-Through In Amperes B 400A 350A 315A 250A 200A 160A 125A 100A 80A 63A 50A 630A 550A 500A 450A 400A 350A 315A 250A 200A 160A 104 103 A A 2x102 1x10 2 3 4 10 10 10 Prospective Short-Circuit Current Symmetrical RMS 5 10 6 2x102 1x102 103 104 105 Prospective Short-Circuit Current Symmetrical RMS 630A fuse is derated to 1100V (IEC). Data Sheet: 17056630 166 105 Peak Let-Through Curve Peak Let-Through Curve Peak Let-Through Current 1x102 Data Sheet: 17056632 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 106 High Speed Fuses Square Body Size 2, 3 -- 1250V/1300V (IEC/UL): 50-1400A Size 3 -- 315-1400A: 1250V Time-Current Curve Time-Current Curve 250A 280A 315A 350A 400A 450A 500A 550A 630A 700A 800A 900A 1000A Size 2 -- 250-1000A: 1250V 104 103 102 High Speed Fuses Virtual Pre-Arcing Time In Seconds A A 101 100 10-1 10-2 10-3 1x10-4 1x102 103 104 Prospective Current In Amp RMS 105 Peak Let-Through Curve Peak Let-Through Curve 105 104 B 1250A 1100A 1000A 900A 800A 700A 630A 550A 500A 450A 400A 350A 315A 104 103 103 A A 2x10 1400A 105 1000A 900A 800A 700A 630A 550A 500A 450A 400A 315A 350A 280A 250A Peak Let-Through Current Peak Let-Through Current B 2x102 2 1x102 103 104 105 Prospective Short-Circuit Current Symmetrical RMS 106 1x102 103 104 105 Prospective Short-Circuit Current Symmetrical RMS 900-1000A fuses are derated to 1100V (IEC). 1250-1400A fuses are derated to 1100V (IEC). Data Sheet: 17056634 Data Sheet: 17056636 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 106 167 High Speed Fuses Square Body Flush End Contact Size 4 -- 1250V (IEC): 1400-2500A 1250V (IEC) 1400-2500A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg , (rms) at a power factor of 15%. Specifications Description: High speed square body fuses, for the protection of the power rectifier section of the equipment. Dimensions: See dimensions illustration. Ratings: Volts: -- 1250Vac (IEC) Amps: -- 1400-2500A IR: -- 125kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Electrical Characteristics Total clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters For Other Voltage Ratings in This Body Style * See pages 135 (690V/700V) and 154 (1000V) Catalog Numbers Fuse Size 4 Catalog Number -SBKN/105 -BKN/105 Type K Type K Indicator Indicator 170M7217 170M7597 170M7676 170M7532 170M7633 170M7592 170M7107 170M7595 170M7512 170M7510 170M7511 170M7976 170M7513 170M7546 170M7516 170M7978 Rated Voltage (V) 1250 Electrical Characteristics 2 2 Rated I t (A Sec) Current Clearing RMS-Amp at 1250V Pre-arc 1400 800000 5000000 1500 1000000 6200000 1700 1400000 8700000 1800 1700000 11000000 2000 2300000 14500000 2200 3100000 19500000 2400 4000000 25000000 2500 4500000 28000000 Watt Loss (W) 195 200 220 225 235 245 255 260 Data Sheet: 170K6640 , 170K6642 168 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body Flush End Contact Size 4 -- 1250V (IEC): 1400-2500A Flush End Contact - Size 4 1250V (IEC) / 1400 - 2500A Dimensions (mm): Type 4BKN/105 High Speed Fuses 106.6 Type 4SBKN/105 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 169 High Speed Fuses Square Body Flush End Contact Size 4 -- 1250V (IEC): 1400-2500A Size 4 -- 1400-2400A: 1250V Size 4 -- 2300-2500A: 1250V Time-Current Curve Time-Current Curve Prospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request 170 Prospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body Flush End Contact Size 23-- 1250V (IEC/UL): 630-2800A 1250V (IEC) 630-2800A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg , (rms) at a power factor of 15%. Specifications Description: High speed square body fuses, for the protection of the power rectifier section of the equipment. Dimensions: See dimensions illustration. Ratings: Volts: -- 1250Vac (IEC) Amps: -- 630-2800A IR: -- 125kA RMS Sym. Agency Information: CE, Designed and tested to IEC 60269: Part 4, UL Recognized. Power Losses Electrical Characteristics Total clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters High Speed Fuses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. For Other Voltage Ratings in This Body Style * See pages 137 (660V) and 157 (1000V) Catalog Numbers Fuse Size 23 -BU/75 without Indicator -BKE/75 Type K Indicator Catalog Number -BKN/75 -BU/80 Type K without Indicator Indicator 170M6775 170M6776 170M6777 170M6805 170M6778 170M6779 170M6780 170M6781 170M6782 170M6783 170M6795 170M6796 170M6797 170M6807 170M6798 170M6799 170M6800 170M6801 170M6802 170M6803 170M6785 170M6786 170M6787 170M6806 170M6788 170M6789 170M6790 170M6791 170M6792 170M6793 -BKE/80 Type K Indicator -BKN/80 Type K Indicator Rated Voltage (V) 1250 170M6784 170M6815 170M6816 170M6817 170M6804 170M6833 170M6834 170M6835 170M6794 170M6827 170M6828 170M6829 1100 Electrical Characteristics 2 2 Rated I t (A Sec) Current Clearing at RMS-Amp Pre-arc 1250V 630 38000 310000 700 54000 440000 800 78000 640000 900 120000 980000 1000 155000 1250000 1100 220000 1750000 1250 330000 2700000 1400 460000 3800000 1600 820000 5200000 1800 1200000 7600000 2000 1800000 11000000 2200 2300000 14500000 16000000 2500 3200000 2800 5000000 24000000 Watts Loss (W) 170 180 190 200 210 220 230 240 250 260 270 280 290 300 A2s @ 1000V Data Sheet: 170K6638 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 171 High Speed Fuses Square Body Flush End Contact Size 23-- 1250V (IEC/UL): 630-2800A Flush End Contact - Size 23 1250V (IEC) / 1000 - 4000A Size 23 -- 630-2800A: 1250V Time-Current Curve Dimensions (mm): Prospective Current in Amps RMS Peak Let-Through Curve 172 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Square Body Flush End Contact Size 5-- 1000V-2000V: 1800-5000A 1000V (IEC) 1800-5000A * * * * High Speed Fuses Specifications Description: High speed square body fuses, for the protection or isolation for components such as diodes, silicon controlled rectifiers (SCRs), Gate torn-Off Thyristors (GTOs) and IGBTs. Dimensions: See dimensions illustration. Ratings: Volts: -- 1000-2000Vac (IEC) Amps: -- 1800-5000A IR: -- 300kA RMS Sym. estimated, 197kA tested Agency Information: Consult Cooper Bussmann. bulehighspeedtechnical@cooperindustries.com Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability Typical Applications * AC and DC drives * High power converters/rectifiers Diemensions - mm (in) This dimension drawing is an example of the range of size 5 fuses available. Contact Cooper Bussmann for available parts and technical information. For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 173 High Speed Fuses Square Body DC Fuses -- 750Vdc: 63-500A 750Vdc 63-500A Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Specifications Description: High speed fuses, for the protection of DC circuits in equipment. Dimensions: See dimensions illustration. Ratings: Volts: -- 750Vdc Amps: -- 63-500A IR: -- 750Vdc IR: 100kA, L/R = 100 ms. -- 1000Vdc IR: 100kA, L/R = 40 ms Agency Information: Consult Cooper Bussmann. Electrical Characteristics Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg. * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters Catalog Numbers Catalog Numbers Fuse Size 1* 1 2 3 -BK/130 -EK/- 170E3577 170E3578 170E3579 170E3580 170E3581 170E5417 170E5418 170E8335 170E8336 170E8337 170E9681 170E3583 170E3584 170E3585 170E3586 170E3587 170E5420 170E5421 170E8345 170E8346 170E8347 170E9685 Electrical Characteristics Rated Rated Watt Voltage Current Loss (Vdc) RMS-Amp (W) 750 63 80 100 125 160 200 250 250 315 400 500 10.0 13.0 16.0 21.0 26.0 37.0 46.0 47.0 57.0 73.0 91.0 Data Sheet: Size 1*: 170K3620 Size 1: 170K3622 Size 2: 170K3624 Size 3: 170K3626 Microswitch: 170H0069, 170H3027 (gold) 174 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com High Speed Fuses Square Body DC Fuses -- 750Vdc: 63-500A Square Body DC Fuses 750Vdc / 63 - 500A (mm): Type -BK/130 High Speed Fuses Size/Type 1* BK/130 1 BK/130 2 BK/130 3 BK/130 A 129 130 130 131 B 43 51 59 74 D 61 69 77 90 Type -EK/- Size/Type 1* EK/155 1 EK/165 2 EK/170 3 EK/170 A 124 124 124 125 B 156 166 170 170 C 129 129 129 130 D 180 191 205 206 E 43 51 59 74 F 36 37 42 51 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com G 41 41 48 56 H 9 11 13 13 I 9 14 21 20 J 18 25 30 36 175 High Speed Fuses Square Body DC Fuses -- 750Vdc: 63-500A Square Body DC Fuse -- 63-160A: 750V Square Body DC Fuse -- 200-250A: 750V Time-Current Curve Time-Current Curve Prospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request 176 Prospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request For detailed information, visit the Electrical IEC section at www.cooperbussmann.com High Speed Fuses Square Body DC Fuses -- 750Vdc: 63-500A Square Body DC Fuse -- 250-400A: 750V Square Body DC Fuse -- 500A: 750V Time-Current Curve Time-Current Curve High Speed Fuses Prospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request Prospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 177 High Speed Fuses Square Body DC Fuses -- 1200Vdc: 160-420A 1200Vdc 160-420A Power Losses Specifications Description: High speed fuses that provides superior protection in light and heavy harsh DC traction applications as 1200Vdc and below circuits, and as DC link/power converters. Dimensions: See dimensions illustration. Ratings: Volts: -- 1200Vdc Amps: -- 160-420A IR: -- 1200Vdc = 100kA L/R: 15 ms. Agency Information: Consult Cooper Bussmann. Electrical Characteristics Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg. Catalog Numbers Cat. Numbers Fuse Type 2SKN / 140 -SKNB/140 Type K Indicator 170F8230 170F8231 170F8232 170F8233 170F8234 170F8235 Rated Voltage (Vdc) 1200 Electrical Characteristics Max I2t (A2Sec) @ 1000Vdc Rated Current RMS-Amp L/R = 15ms L/R = 45ms 160 12000 20000 200 20000 35000 250 43000 75000 315 87000 150000 400 180000 310000 420 215000 375000 Watts Loss (W) 75.0 85.0 94.0 104.0 120.0 122.0 Data Sheet: 170K5520 Microswitch: 170H0069, 170H3027 (gold) Dimensions (mm): 178 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com High Speed Fuses Square Body DC Fuses -- 1200Vdc: 160-420A Square Body DC Fuse -- 160-420A: 1200V Time-Current Curve High Speed Fuses Prospective Current in Amps RMS Data Sheet: Available upon request For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 179 High Speed Fuses Square Body DC fuses -- 2000Vdc: 10-125A 2000Vdc 10-125A Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Specifications Description: High speed fuses for the protection of DC circuits in equipment. Dimensions: See dimensions illustration. Ratings: Volts: -- 1200Vdc Amps: -- 160-420A IR: -- 1200Vdc = 100kA L/R: 15 ms. Agency Information: Consult Cooper Bussmann. Electrical Characteristics Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg. * * * * Features and Benefits Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss Superior cycling capability * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters Catalog Numbers Fuse Type 1*SKN/246 Cat. Number Electrical Characteristics Rated -SKN/246 Rated Watt Voltage Type K Current Loss (Vdc) Indicator RMS-Amp (W) 170E3976 170E3970 170E3950 170E3951 170E3952 170E3953 170E3954 170E3955 170E3956 2000 10 16 20 25 32 40 50 63 80 7 11 13 17 22 27 34 43 50 Fuse Type 1*SKN/246 Cat. Number Electrical Characteristics Watt -SKN/246 Rated Rated Loss Type K Current Voltage (W) Indicator RMS-Amp (Vdc) 170E3937 20 13 170E3938 25 16 170E3939 32 20 170E3940 40 25 170E3941 2000 50 32 170E3942 63 40 170E3943 80 51 170E3944 100 64 170E3945 125 80 2000Vdc / 10 - 125A Dimensions (mm): Data Sheet: 170K4538 Microswitch: 170H0239, 170H3030 (gold) Data Sheet: 170K4900 Microswitch: 170H0239, 170H3030 (gold) 180 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com High Speed Fuses Square Body DC fuses -- 2000Vdc: 10-125A Square Body DC Fuses -- 10-80A: 2000V Square Body DC Fuses -- 20-125A: 2000V Time-Current Curve Time-Current Curve High Speed Fuses Prospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request Prospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 181 High Speed Fuses Square Body DC Fuses -- 4000Vdc: 20-450A 4000Vdc 20-450A Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Specifications Description: High speed fuses for the protection of DC circuits in equipment. Dimensions: See dimensions illustration. Ratings: Volts: -- 4000Vdc Amps: -- 20-450A IR: -- 60kA L/R: 25 ms. Agency Information: Consult Cooper Bussmann. Features and Benefits * Excellent DC performance * Low arc voltage and low energy let-through (I2t) * Low watts loss * Superior cycling capability Electrical Characteristics Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage Eg. * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters Catalog Numbers Fuse Type 1*SKN/394 2 SKN/394 2//2SKN/394 182 Cat. Numbers -SKN/394 Rated Type K Voltage Indicator (Vdc) 170E3914 170E3915 170E3916 170E3917 170E3918 170E3919 170E3984 170E3933 170E3922 170E8882 170E8883 170E8884 170E8885 170E8886 170E8887 170E8888 4000 Electrical Characteristics Rated Watts Current Loss RMS-Amp (W) 20 25 32 40 50 63 80 100 125 160 200 250 315 350 400 450 23 28 34 45 57 72 91 114 143 182 228 285 360 400 455 515 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com High Speed Fuses DC Fuses -- 4000Vdc: 20-450A DC Fuses 4000Vdc / 20 - 450A Dimensions (mm): Type 1*SKN/394 High Speed Fuses Type 2SKN/394 Type 2//SKN/394 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 183 High Speed Fuses Square Body DC Fuses -- 4000Vdc: 20-450A Square Body DC Fuses -- 20-125A: 2000V Square Body DC Fuses -- 160-450A: 4000V Time-Current Curve Time-Current Curve Prospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request 184 Prospective Current in Amps RMS Peak Let-Through Curve Data Sheet: Available upon request For detailed information, visit the Electrical IEC section at www.cooperbussmann.com High Speed Fuses Square Body Fuse Accessories Indicator Systems Typower ZILOX fuses are available with three different indicator systems. 1. Visual Indicator The indicator situated in one cover plate is clearly visible as soon as the fuse has operated. The minimum voltage for operating the indicator is 20V. 2. Type T Indicator The indicator is situated on one cover plate with a cover plate tag to accommodate an auxiliary switch. The minimum voltage for operating the indicator is 20V. A special low voltage indicator (1.5V) is available on request. High Speed Fuses 3. Type K Indicator This indicator is situated on the fuse body. It is covered by an adapter for snap-on mounting of an auxiliary switch. The operating voltage of the indicator is 1.5V. As a matter of safety, the factory mounted adapter must not be removed from the fuse. Microswitch The Typower ZILOX fuses with either type T indicator or type K indicator can be equipped with a microswitch for remote electrical indication of fuse operations. All micro-switches have one normally open and one normally closed contact. Ratings are 2A, 250Vac. Microswitch 170H0235 170H0236 170H0237 170H0238 170H0069 Size 000 00 1* 1 2 3 4 23 24 6.3 x 0.8mm Lugs X X DIN 43 653 Type T 170H0236 170H0238 170H0235 170H0237 170H0235 170H0237 170H0235 170H0237 170H0235 170H0237 170H0235 170H0237 2.8 x 0.5mm Lugs X X X DIN 43 620 Type T 170H0236 170H0238 Type K Indicator Type T T T T K Type K French Style Type T Type K US Style Type K 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 Type K Flush End Type T 170H0235 170H0237 170H0069 170H0235 170H0237 170H0069 170H0069 170H0069 170H0235 170H0237 170H0236 170H0238 170H0236 170H0238 170H0236 170H0238 170H0236 170H0238 170H0236 170H0238 170H0069 170H0069 170H0069 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 185 High Speed Fuses Square Body Fuse Accessories Fuse Bases (Blocks) 170H3004 DIN 43 653 Fuse Bases For the Typower ZILOX fuses according to DIN 43 653, the following fuse bases are available: Catalog Number 170H3003 170H3004 170H3005 170H3006 Max Volts 1000 1000 1400 1400 Amp Rating 630 1250 630 1250 Center Distance 80mm 80mm 110mm 110mm The fuse bases rated 1250A can also be used for the fuses with higher rated current if the maximum load current is derated according to the table below: Fuse Amp Rating 1400 1500 1600 1800 2000 Fixed Center Base Style 170H1007 170H1013 Max Amp Load In Fuse Base 1325 1400 1500 1650 1800 Max Volts 1000 660 Max. Fuse Amp Rating 400 200 Fuse Size 00, 000 0000,000 170H1013 UL Recognized to UL 512. Universal Fuse Bases For the Typower ZILOX fuses according to DIN 43 653, French style and North American style, the following fuse bases are available: Modular Base Style 1BS101 1BS102 1BS103 1BS104 BH-0xxx BH-1xxx BH-2xxx BH-3xxx Max Volts 600 600 600 600 700 2500 5000 1250 Max. Fuse Amp Rating 100 400 400 600 200 400 400 700 Data Sheet 1206 1207 1208 1209 1200 1201 1202 1203 Modular fuse bases are UL Recognized to UL 512 and meet the spacing requirements of UL 347. Contact your Cooper Bussmann sales representative for more complete ordering information. 1BS Series Example DIN 43 620 Fuse Bases Size 000-00 1*, 1 2,3 186 Part Number SB00-D SB1-D SB2-D For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses British BS 88 Fuses High Speed Fuses Introduction General Information British BS 88 Contents Fuse Amp Volts Range 240 6-900 690 6-710 Page 188-190 191-194 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps 6-900 6-710 Vac 240 690 Vdc 150 500 Designed and tested to: * BS 88: Part 4 * IEC 269: Part 4 * UL Recognized Cooper Bussmann offers the industry's widest range of British style semiconductor fuses and accessories. Cooper Bussmann British style products use innovative arc quenching techniques and high grade materials to provide: * Minimal energy let-through (I2t) * Excellent DC performance * Good surge withstand profile British style fuses are typically found in equipment manufactured in the United Kingdom or British Commonwealth countries. However, North American manufacturers have begun to specify British style fuses -- particularly in UPS applications at 240V or less -- to take advantage of their size, performance and cost benefits. Voltage Rating All Cooper Bussmann British style fuses are tested to IEC 269: Part 4. This standard requires a test voltage which is 5% higher than the rated voltage. In North America, fuses are required to clear only their rated voltage. Accessories Trip-indicator fuses are available for use in parallel with the main fuse. Indicator fuses can be attached to the associated fuselink, or mounted separately in panel-mounted fuseclips. In addition, a push-on adapter and microswitch attachment are available, to provide remote indication. Fuse blocks are also available for most applications. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 187 High Speed Fuses British BS 88 -- 240V: 6-900A LCT, LET, LMT, LMMT Arc Voltage Specifications Description: BS 88 style stud-mount fuses. Dimensions: See dimensions illustrations. Ratings: Volts: -- 240Vac/150Vdc Amps: -- 6-900A IR: -- 200kA RMS Sym. Agency Information: CE, Designed and tested to: BS 88 Part 4, IEC 269 Part 4, UL Recognized. All fuses above have been tested at 318Vac. Consult Cooper Bussmann for specific UL Recognition status. Electrical Characteristics 1.6 Total Clearing I2t K 1.4 The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1.2 1.0 0.8 0.4 2) Eg 50 100 150 200 250 Fig. 2: LET 7.1 4 5.5 26.2 41.8 56 28 38 47 9.7 12.7 6.4 17.7 8.4 19.1 8.7 Fig. 4: LMMT Fig. 3: LMT 1mm = 0.0394" / 1" = 25.4mm 25.4 25.4 31 59 31 59 84 13.5 13.5 10.3 10.3 41 83 38.1 Indicator (Optional) 1) 500 2) 250 Eg 100 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. 300 1.0 Kp 0.8 0.6 0.5 0.4 0.3 0.2 Ib 0.1 30 40 50 38 84 Catalog Numbers 6LCT 10LCT 12LCT 16LCT 20LCT 25LET 32LET 35LET 50LET 63LET 80LET 100LET 125LET 160LET 180LETa 160LMT 200LMT 250LMT 315LMT 355LMT 400LMT 450LMT 400LMMT 500LMMT 630LMMT 710LMMT 800LMMT 900LMMT Type LCT LET LMT LMMT Rated Current RMS-Amps 6 10 12 16 20 25 32 35 50 63 80 100 125 160 180 160 200 250 315 355 400 450 400 500 630 710 800 900 Pre-arc 2 3.8 7 20 25 18 32 50 100 180 300 600 600 1100 1600 1100 1500 3200 6000 8000 14000 18000 6000 14000 24000 32000 52000 75000 60 70 80 90 100% I2t (A2 Sec) Clearing at 120V 6 12 22 50 80 120 200 320 500 1100 1900 3800 3800 7000 12000 7000 10000 20000 35000 50000 70000 100000 35000 80000 150000 200000 300000 400000 Clearing at 240V 9 22 32 100 160 250 450 600 1400 2200 3800 7500 7500 16000 29000 16000 20000 40000 75000 100000 160000 220000 80000 170000 300000 460000 600000 800000 Watts Loss 1.0 2.5 2.5 2.5 4.0 4.0 5.0 5.0 7.0 9.0 10.0 10.0 16.0 20.0 21.0 17.0 28.0 28.0 35.0 35.0 40.0 42.0 60.0 64.0 75.0 77.0 82.0 97.0 * Watts loss provided at rated current. * Note: 7LET, 10LET, 12LET and 16LET are available for replacement purposes on existing equipment. * See accessories on page 195. Features and Benefits * Excellent cycling capability * Excellent DC performance * Low arc voltage and low energy let-through (I2t) Typical Applications * DC common bus * AC and DC drives * Power converters/rectifiers * Reduced voltage starters Data Sheet: 720004 188 200 1) LCT 2) LET, LMT, LMMT Electrical Characteristics 1) 0.2 UL Power Losses Catalog Numbers 0.6 1) LCT 2) LET, LMT, LMMT Dimensions (mm) Fig. 1: LCT 750 This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses British BS 88 -- 240V: 6-900A LCT 6-20A: 240V LET 25-180A: 240V Time-Current Curve Time-Current Curve 104 104 6 4 6 4 2 2 103 103 6 4 6 4 2 6LCT 10LCT 12LCT 16LCT 20LCT 102 6 4 2 102 2 Virtual Pre-Arcing Time In Seconds 2 101 6 4 2 100 6 4 2 10-1 101 6 4 25LET 32LET 35LET 50LET 63LET 2 100 6 4 High Speed Fuses 2 10-1 6 4 6 4 2 2 10-2 10-2 6 4 6 4 2 2 10-3 6 4 10-3 6 4 2 2 10-4 2 4 6 8 2 4 6 8 101 102 Prospective Current In Amps RMS 2 4 6 8 10-4 103 2 101 4 6 8 102 2 4 6 8 103 Prospective Current In Amps RMS Data Sheet: 35785296 Data Sheet: 35785293 Peak Let-Through Curve 2 105 900LMMT 800LMMT 710LMMT 630LMMT 450LMT 400 & 500LMMT 355LMT 315LMT 250LMT 6 4 2 104 180LET 200LMT 160LET & LMT 125 & 100LET 80LET 6 Peak Let-Through Current Virtual Pre-Arcing Time In Seconds 80LET 100LET 125LET 160LET 180LETa 6 4 4 2 103 6 4 63LET 50LET 35LET 32LET 25LET 2 2 10 20LCT 16LCT 12LCT 10LCT 6LCT 6 4 2 SYMMETRICAL FAULT FULLY ASYMMETRICAL FAULT 101 101 2 4 6 102 2 4 6 103 2 4 6 104 2 4 6 105 Prospective Short-Circuit Current Symmetrical RMS For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 189 High Speed Fuses British BS 88 -- 240V: 6-900A LMT 160-450A: 240V LMMT 400-900A: 240V Time-Current Curve Time-Current Curve 104 6 4 104 6 4 2 2 103 103 6 4 6 4 2 101 6 4 400LMMT 500LMMT 630LMMT 710LMMT 800LMMT 900LMMT 102 6 4 Virtual Pre-Arcing Time In Seconds 2 Virtual Pre-Arcing Time In Seconds 2 160LMT 200LMT 250LMT 315LMT 355LMT 400LMT 450LMT 102 6 4 2 100 6 4 2 10-1 6 4 2 101 6 4 2 100 6 4 2 10-1 6 4 2 2 10-2 6 4 10-2 6 4 2 2 10-3 10-3 6 4 6 4 2 2 10-4 102 2 4 6 8 103 2 4 6 10-4 8 104 2 102 Prospective Current In Amps RMS 4 6 8 103 2 Data Sheet: 35785294 Data Sheet: 35785295 Peak Let-Through Curve 2 105 900LMMT 800LMMT 710LMMT 630LMMT 450LMT 400 & 500LMMT 355LMT 315LMT 250LMT 6 4 2 10 4 180LET 200LMT 160LET & LMT 125 & 100LET 80LET Peak Let-Through Current 6 4 2 103 6 4 63LET 50LET 35LET 32LET 25LET 2 102 20LCT 16LCT 12LCT 10LCT 6LCT 6 4 2 SYMMETRICAL FAULT FULLY ASYMMETRICAL FAULT 101 10 1 2 4 6 102 2 4 6 103 2 4 6 104 2 4 6 105 Prospective Short-Circuit Current Symmetrical RMS 190 4 Prospective Current In Amps RMS For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 6 8 104 High Speed Fuses British BS 88 -- 690V: 6-710A CT, ET, FE, EET, FEE, FM, FMM, MT, MMT Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: BS 88 style stud-mount fuses. Dimensions: See dimensions illustrations. Ratings: Volts: -- 690Vac/500Vdc Amps: -- 6-710A IR: -- 200kA RMS Sym. Agency Information: CE, Designed and tested to: BS 88 Part 4, IEC 269 Part 4, UL Recognized. MT and MMT -- 350Vdc (IEC) rating. Consult Cooper Bussmann for UL Recognition status. 1.2 1.0 0.8 1) 400 Fig. 2: ET, FE 600 660 1.0 Kp 0.8 0.6 0.5 0.4 0.3 0.2 Ib 0.1 30 40 50 60 Fig. 3: EET, FEE Fig. 4: FM, MT 600 690 8.7 7.1 Fig. 5: FMM, MMT 25.4 4 80 90 100% 70 Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 500 1) CT, ET, EET, FE, FEE, MT, MMT 2) FM, FMM Dimensions (mm) Fig. 1: CT 400 1) CT 2) ET, FE, EET, FEE, FM, FMM * * * * Eg 300 Eg Features and Benefits Excellent cycling capability Excellent DC performance Low arc voltage and low energy let-through (I2t) Low watts loss 2) 200 500 * * * * 0.6 0.2 2) High Speed Fuses K 1.4 0.4 1000 200 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Total Clearing I2t 1.6 1) Power Losses Electrical Characteristics The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). UL 1500 25.4 5.5 50 46 70 94 48 63.5 77 50 54.8 64.3 74.6 A 6.4 8.7 8.7 13.5 19.1 10.3 31.8 10.3 37 19 41 38.1 1mm = 0.0394" / 1" = 25.4mm Data Sheet: 720024 113 14 11.9 9.7 12.7 17.1 A 113 83 38 Figs. 4 & 5 "A" Dimensions Type "A" FM 80-85mm FMM 80-85mm MT 85mm MMT 85mm For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 191 High Speed Fuses British BS 88 -- 690V: 6-710A Catalog Numbers CT ET FE EET FEE FM FMM MT MMT CT 6-20, ET 25-80A: 690V Watts Loss 2 3 3 7 7 7 11 11 9 11 14 16 18 9 9 11 11 12 17 20 20 23 19 27 35 39 24 32 36 46 46 52 40 40 44 48 48 55 55 85 90 100 100 100 120 26 26 27 32 35 42 51 42 42 42 47 51 54 60 57 64 64 86 105 * Watts loss provided at rated current. * Note: FC, 8ET, 12ET, 15ET, 20ET, 65EET and 75EET are available for replacement purposes on existing equipment. * See accessories on page 195. Time-Current Curve 104 6 4 2 103 6 4 25ET 32ET 35ET 40ET 45ET 56ET 63ET 80ET 2 102 6 4 Virtual Pre-Arcing Time In Seconds Type Electrical Characteristics I2t (A2 Sec) Clearing Clearing Pre-arc at 415V at 660V 1.8 8.5 12 7 30 48 10 40 65 16 66 110 32 150 220 25 150 250 32 190 350 52 310 500 103 600 900 103 680 1100 135 950 1500 171 1200 2000 360 2500 4000 33 130 200 52 180 300 76 270 450 103 380 600 135 480 750 210 600 950 250 900 1500 360 1300 2100 470 1800 2800 490 3000 4500 600 4000 6500 1050 7000 12000 1500 10000 17000 400 1600 2400 540 1900 3100 850 2500 3800 1000 3700 5700 1400 5300 8400 1900 7100 11400 1400 7500 13500 2600 10500 18500 3700 14500 26500 5200 20500 37500 7000 30500 55000 10000 40000 77000 15000 60000 105000 10000 40000 72500 15000 60000 105000 20000 82000 150000 30000 120000 215000 45000 180000 310000 60000 245000 420000 2400 15000 25000 3800 25000 38000 6000 40000 58000 11500 80000 110000 16500 100000 150000 19000 125000 180000 22000 160000 200000 1650 12000 18000 2200 16000 23000 3700 26000 40000 6600 47000 70000 8600 62000 91000 13500 97000 140000 21000 150000 220000 30000 220000 320000 42000 300000 450000 60000 430000 640000 68500 500000 720000 78000 600000 850000 2 101 6 4 6CT 10CT 12CT 16CT 20CT 2 100 6 4 2 10-1 6 4 2 10-2 6 4 2 10-3 6 4 2 10-4 2 4 6 8 101 2 4 6 8 102 2 6 8 103 Peak Let-Through Curve 6 4 2 315MT 355MT 280MT 250MT 105 6 180MT 160MT 4 710MMT 630MMT 560MMT 500MMT 450MMT 400MMT 355MMT 315MMT 280MMT 200MT 225MMT 200MMT 180MMT 2 104 6 4 2 103 6 160EET 140EET 110EET 90EET 4 80ET 63ET 56ET 45ET 40ET 35ET 32ET 25ET 2 20CT 16CT 12CT 10CT 6CT 102 6 4 2 101 101 2 4 6 102 2 4 6 103 2 4 6 104 Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785312 192 4 Prospective Current In Amps RMS Peak Let-Through Current Catalog Numbers 6CT 10CT 12CT 16CT 20CT 25ET 32ET 35ET 40ET 45ET 56ET 63ET 80ET 35FE 40FE 45FE 50FE 63FE 71FE 80FE 90FE 100FE 90EET 110EET 140EET 160EET 100FEE 120FEE 140FEE 160FEE 180FEE 200FEE 180FM 200FM 225FM 250FM 280FM 315FM 350FM 400FMM 450FMM 500FMM 550FMM 630FMM 700FMM 160MT 180MT 200MT 250MT 280MT 315MT 355MT 180MMT 200MMT 225MMT 280MMT 315MMT 355MMT 400MMT 450MMT 500MMT 560MMT 630MMT 710MMT Rated Current RMS-Amps 6 10 12 16 20 25 32 35 40 45 56 63 80 35 40 45 50 63 71 80 90 100 90 110 140 160 100 120 140 160 180 200 180 200 225 250 280 315 350 400 450 500 550 630 700 160 180 200 250 280 315 355 180 200 225 280 315 355 400 450 500 560 630 710 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 2 4 6 105 2 High Speed Fuses British BS 88 -- 690V: 6-710A EET 90-160A, MT 160-355A: 690V MMT 180-710A: 690V Time-Current Curve Time-Current Curve 104 104 6 4 6 4 2 2 103 160MT 180MT 200MT 250MT 280MT 315MT 355MT 6 4 2 102 6 4 6 4 2 102 6 4 Virtual Pre-Arcing Time In Seconds 2 101 6 4 90EET 110EET 140EET 160EET 2 100 6 4 2 10 -1 6 4 6 4 2 100 6 4 2 10-1 6 4 2 10-2 2 6 4 10-2 2 6 4 10-3 6 4 2 10-3 2 10-4 180MMT 200MMT 225MMT 280MMT 315MMT 355MMT 2 101 High Speed Fuses 2 4 6 8 102 2 4 6 8 103 2 4 6 6 4 8 104 2 Prospective Current In Amps RMS 10-4 2 102 4 6 8 2 4 103 Prospective Current In Amps RMS Data Sheet: 35785313 6 8 104 Data Sheet: 35785311 Peak Let-Through Curve 6 4 2 315MT 355MT 280MT 250MT 105 6 180MT 160MT 4 710MMT 630MMT 560MMT 500MMT 450MMT 400MMT 355MMT 315MMT 280MMT 200MT 225MMT 200MMT 180MMT 2 Peak Let-Through Current Virtual Pre-Arcing Time In Seconds 400MMT 450MMT 500MMT 560MMT 630MMT 710MMT 103 104 6 4 2 103 6 160EET 140EET 110EET 90EET 4 80ET 63ET 56ET 45ET 40ET 35ET 32ET 25ET 2 20CT 16CT 12CT 10CT 6CT 102 6 4 2 101 101 2 4 6 102 2 4 6 103 2 4 6 104 2 4 6 105 2 Prospective Short-Circuit Current Symmetrical RMS For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 193 High Speed Fuses British BS 88 -- 690V: 6-710A FE 35-100A & FM 180-350A: 690V FEE 100-200A & FMM 400-700A: 690V Time-Current Curve Time-Current Curve 104 104 6 4 6 4 2 2 103 6 4 103 6 4 2 180FM 200FM 220FM 250FM 280FM 315FM 350FM 2 101 6 4 2 2 35FE 40FE 45FE 50FE 63FE 71FE 80FE 90FE 100FE 100 6 4 2 10-1 6 4 2 101 6 100FEE 4 120FEE 140FEE 2 160FEE 180FEE 100 200FEE 6 4 2 10-1 6 4 2 10-2 6 4 2 10-2 6 4 2 10-3 6 4 2 2 10-4 400FMM 450FMM 500FMM 550FMM 630FMM 700FMM 102 6 4 Virtual Pre-Arcing Time In Seconds Virtual Pre-Arcing Time In Seconds 102 6 4 2 4 6 8 102 2 4 6 8 103 2 4 6 8 104 10-3 6 4 Prospective Current In Amps RMS 2 10-4 2 102 Peak Let-Through Curve 4 6 8 2 4 103 Prospective Current In Amps RMS 630FMM 6 550FMM 4 500FMM 450FMM 4 2 6 2 Peak Let-Through Current 4 Peak Let-Through Current 400FMM 350FM 315FM 280FM 250FM 225FM 200FM 180FM 104 2 103 6 4 2 100FE 90FE 80FE 71FE 63FE 50FE 45FE 40FE 35FE 102 6 4 104 8 6 4 2 103 200FEE 8 2 180FEE 6 2 4 6 102 2 4 6 103 2 4 6 104 2 4 6 105 2 160FEE 140FEE 4 120FEE 100FEE Prospective Short-Circuit Current Symmetrical RMS 2 102 2 4 6 103 2 4 6 104 2 4 Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785314 194 104 700FMM 8 6 101 8 Peak Let-Through Curve 105 101 6 Data Sheet: 35785292 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 6 105 2 High Speed Fuses British BS 88 Fuse Accessories Indicator System CL1 Panel Mount Clips Trip-Indicators CL1 Panel mount fuse clips are available for mounting a trip-indicator when mounting directly on the fuse is impractical. Order part number CL1. Trip-indicators are available for use in parallel with the main fuse. They can either be attached to the associated fuse or mounted separately in panel mounted fuse clips, reference CL1. A push-on adapter and microswitch attachment is available for use with the trip indicator to give the facility of remote indication, reference MAI. Fuse ratings of 20A and below cannot usually accommodate a trip-indicator. Trip-Indicator Dimensions - mm Type Maximum RMS Voltage Maximum Peak Voltage Maximum DC Voltage Cold Resistance (ohms) Maximum permissible steady-state current Interrupting Capacity (RMS Symm.) Pre-Arcing I2t TI500 500 700 130 0.3 1.5A 100,000 23 TI700 700 1000 350 0.45 1.5A 100,000 23 Ref. TI250 TI500 TI600 TI700 TI1100 TI1500 TI2000 TI2500 D Dim. "A" (mm) 37.6 47.5 55.7 61.8 98.4 120.6 147.5 198.3 CL1 Panel Mount Clip Dimensions - mm Fuse Indicator Kits RMS Volts 250 250 660 660 700 F E 0.8 A Electrical Specifications Details Fuse Mount Indicator Kits (Includes one indicator and two clips) B 21 C 6 6.35 High Speed Fuses When a trip-indicator is to be attached to the main fuse an accessory pack comprising a pair of mounting clips and an appropriate trip indicator would be required. The clips are snapped onto the fuse end caps and the indicator is pressed into clips as shown. Kit. Ref. EC-250 MC250 EC-600 MC600 MC700 Trip Indicator 6.8 RMS Volts 250 500 600 700 1100 1500 2000 2500 6.0 8.7 14 For use with Fuse Ref. LET LMT & LMMT FE, FEE & ET FM & FMM MT & MMT 50.8 B Terminal Arrangement Microswitch Adapter - MAI We offer a microswitch, complete with adapter for securing the indicator. The microswitch is provided with double pole, single throw contacts, having both a normally open and a normally closed position. A special material has been employed in the construction of the adapter to provide reliable operation in the range of temperatures associated with standard operating conditions and during fuse operation. NO NC NC NO Dimensions in mm Microswitch and Adapter Type MAI Current Rating: AC 50/60Hz resistive load @ 250V RMS AC 50/60Hz resistive load @ 127V RMS DC, resistive load @ 110Vdc DC, resistive load @ 30Vdc Maximum Working Voltage: Contact-to-contact (RMS) Contact-to-contact (RMS) Maximum DC Volts: 4A 6A 0.7A DC 2A DC 1000V 1500V 110V DC For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 195 High Speed Fuses Ferrule fuses Table of Contents Basic Catalog Number FWA FWX FWH FWC FWP FWK FWJ FWL/FWS Amp Range 5-60 1-50 0.25-30 6-32 1-100 5-60 20-30 2-30 Volts 150 250 500 600 690V/700 750 1000 1250/1500/2000 General Information Page 197-198 199-200 201-204 205-206 207-210 211-212 213-214 215 Accessories Fuse Holders 196 Ferrule fuses provide an excellent solution for small UPS, small ac drives and other low power applications where space is at a premium. 216 Ferrule Fuse Ranges Volts 150 250 500 600 700 (22 x 58mm) 700 (14 x 51mm) 750 1000 1250 1500 2000 Cooper Bussmann offers a full line of ferrule style (cylindrical clip-mounted) fuses, designed and tested to meet standards and requirements in various locations around the world. Their unique design and construction provide: * Superior cycling capability * Low energy let-through (I2t) Amps 5-60 1-50 0.25-30 6-32 20-100 1-50 5-60 20-30 20-30 8-15 2-6 Voltage Rating AC X X X X X X X X X X X DC X X X X -- X X X (800Vdc) X (1000Vdc) X (1000Vdc) X (1000Vdc) All Cooper Bussmann ferrule fuses -- except 690V -- have been tested at their rated voltage. The 690V ferrule fuse has been tested to the IEC 60269 standard, which requires clearing at the rated voltage +5%. Accessories Ferrule fuses may be mounted in fuseclips, fuse holders, fuse blocks or fused switches. A variety of products are available. Please consult Cooper Bussmann Application Engineering to discuss your requirement. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Ferrule -- FWA 150V: 5-60A FWA 5-30A (10 x 38mm) 35-60A (21 X 51mm) Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: Ferrule style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 150Vac/dc Amps: -- 5-60A IR: -- 100kA Sym. Agency Information: CE, UL Recognition 100 Eg 1.5 K 1.0 1) 100 150 1.0 Kp 0.8 0.6 0.5 High Speed Fuses Total Clearing I t 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 80 90 100% Catalog Numbers 0.3 0.2 2) Electrical Characteristics I2t (A2 Sec) Eg 0.15 22 70 102 150 1) 5-30A Range 2) 35-60A Range Dimensions - in (mm) Amp Range 5-30 35-60 200 50 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. 2 0.5 300 Power Losses Electrical Characteristics The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). UL Dimensions A B 1.5 (38.1) 0.375 (9.5) 2.0 (50.8) 0.625 (15.9) A C 0.406 (10.3) 0.811 (20.6) C Catalog Numbers FWA-5A10F FWA-10A10F FWA-15A10F FWA-20A10F FWA-25A10F FWA-30A10F FWA-35A21F FWA-40A21F FWA-45A21F FWA-50A21F FWA-60A21F Size 10 x 38mm (1332" x 112") 21 x 51mm (1316" x 2") Rated Current RMS-Amps 5 10 15 20 25 30 35 40 45 50 60 Pre-arc 1.6 3.6 14 33 58 100 75 100 130 170 250 Clearing at 150V 8 16 55 130 220 400 800 1000 1300 1600 2400 Watts Loss 1 2.7 3.3 3.8 4.9 4.9 4.5 5.1 6 7.3 8.0 * Watts loss provided at rated current. * See accessories on page 216. * * * * Features and Benefits Excellent cycling capability and DC performance Low arc voltage and low energy let-through (I2t) Low watts loss in a compact size Used with finger-safe holders/blocks * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters B Data Sheet: 720003 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 197 High Speed Fuses Ferrule -- FWA 150V: 5-60A FWA 5-30A: 150V (10 x 38mm) FWA 35-60A: 150V (21 x 51mm) Time-Current Curve Time-Current Curve 104 6 4 104 6 4 2 2 6 4 103 6 4 103 2 2 6 4 102 6 4 Virtual Pre-Arcing Time In Seconds Virtual Pre-Arcing Time In Seconds 102 2 101 FWA-5A10F FWA-10A10F FWA-15A10F FWA-20A10F FWA-25A10F FWA-30A10F 6 4 2 100 6 4 2 2 101 6 4 2 100 6 4 2 10-1 6 4 10-1 6 4 2 2 6 4 10-2 6 4 10-2 2 2 6 4 10-3 6 4 10-3 2 2 10-4 FWA-35A21F FWA-40A21F FWA-45A21F FWA-50A21F FWA-60A21F 2 4 6 8 101 2 4 6 8 102 2 4 6 8 10-4 103 2 101 4 Prospective Current In Amps RMS Peak Let-Through Curve 8 2 102 4 6 8 103 Peak Let-Through Curve 104 104 FWA-60A21F FWA-50A21F FWA-45A21F FWA-40A21F FWA-35A21F 6 6 4 4 FWA-30A10F FWA-25A10F FWA-20A10F FWA-15A10F 103 2 10 Peak Let-Through Current 2 Peak Let-Through Current 6 Prospective Current In Amps RMS 6 4 2 FWA-12A10F FWA-10A10F FWA-5A10F 102 3 6 4 2 102 6 6 4 4 2 2 101 101 2 4 6 102 2 4 6 103 2 4 6 104 Prospective Short-Circuit Current Symmetrical RMS 2 4 6 105 2 101 101 2 4 6 102 2 4 6 103 2 4 6 104 Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785317 198 Data Sheet: 35785305 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 2 4 6 105 2 High Speed Fuses Ferrule -- FWX 250V (UL): 1-50A FWX (14 x 51mm) Arc Voltage Specifications Description: Ferrule style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 250Vac/dc Amps: -- 1-50A IR: -- 200kA RMS Sym. -- 50kA @ 250Vdc Agency Information: CE, UL Recognition 1-50A & CSA Component Acceptance: 5-30A 1.0 Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 0.5 600 500 400 1) 2) 0.3 0.2 1) 300 2) Eg 200 50 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. K Characteristics 800 Power Losses 1.5 UL 103 100 150 200 250 1.0 Kp 0.8 0.6 0.5 High Speed Fuses Electrical 1.4 1.2 This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 80 90 100% Catalog Numbers Eg 0.15 75 125 200 250 Dimensions - mm (inches) 50.8 (2.000") 14.3 (0.563") 15.5 (0.610") 300 Catalog Number FWX-1A14F FWX-2A14F FWX-3A14F FWX-4A14F FWX-5A14F FWX-10A14F FWX-15A14F FWX-20A14F FWX-25A14F FWX-30A14F FWX-50A14F Size 14 x 51mm (916" x 2") Electrical Characteristics Rated I2t (A2Sec) Current Clearing RMS-Amps Pre-arc at 250V 1 -- -- 2 -- -- 3 -- -- 4 -- -- 5 1.6 13 10 3.6 24 15 14 83 20 33 200 25 58 300 30 100 500 50 200 1800 Watts Loss -- -- -- -- 1.3 3.4 3.8 4.6 5.3 5.9 5.7 * Watts loss provided at rated current. * (250Vdc/Interrupting rating 50kA) UL Recognition & CSA Component Acceptance on 5 through 30A only. Consult Cooper Bussmann for additional ratings. * See accessories on page 216. * * * * Features and Benefits Excellent cycling capability and DC performance Low arc voltage and low energy let-through (I2t) Low watts loss in a compact size Used with finger-safe holders/blocks * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters Data Sheet: 720006 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 199 High Speed Fuses Ferrule -- FWX 250V (UL): 1-50A FWX 1-30A: 250V (14 x 51mm) Time-Current Curve Prospective Current In Amps RMS Peak Let-Through Curve Prospective Current In Amps RMS Data Sheet: 35785302 200 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Ferrule -- FWH 500V: 0.25-30A FWH (6 x 32mm) Catalog Numbers Amp Ratings 0.25-7 10-30 150% > 30 min < 30 min 200% < 30 min < 30 min 300% 10 sec 10 sec Dimensions - mm (inches) 31.8 (1.25") 6.4 (0.25") Catalog Numbers Size FWH-.250A6F FWH-.500A6F FWH-001A6F FWH-002A6F FWH-3.15A6F FWH-005A6F FWH-6.30A6F 6 x 32mm FWH-007A6F (14" x 114") FWH-010A6F FWH-12.5A6F FWH-015A6F FWH-016A6F FWH-020A6F FWH-025A6F FWH-030A6F Rated Current RMS-Amps 0.25* 0.5* 1* 2* 3.15* 5* 6.3* 7* 10** 12.5** 15** 16** 20** 25** 30** Electrical Characteristics I2t (A2 Sec) Clearing Pre-arc at 500V 0.01 0.05 0.05 0.25 0.4 2 1.3 3.5 3.1 7.7 15 40 36 90 50 125 9.9 139 20 60 44 146 48 177 75 259 126 345 145 430 Watts Loss 2.7 1.2 1.7 3.2 2.9 2.1 2.3 2.5 2.86 3.53 3.08 4.48 4.26 -- -- *300% minimum opening current at rated voltage. **200% minimum opening current at rated voltage. * Consult Cooper Bussmann for DC ratings. * See accessories on page 216. * * * * Features and Benefits Excellent cycling capability and DC performance Low arc voltage and low energy let-through (I2t) Low watts loss in a compact size Used with finger-safe holders/blocks * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 3.2 (0.125") Data Sheet: 720038 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 201 High Speed Fuses Specifications Description: Ferrule style high speed fuses. Dimensions: See dimensions illustrations. Ratings: Volts: -- 500Vac Amps: -- 0.25-30A IR: -- 50kA at 20% pf (0.25-20A) -- 20kA at 20% pf (25-30A) Agency Information: CE, UL Recognition 0.25-30A, CSA Component Acceptance: 0.25-7A Opening Times High Speed Fuses Ferrule -- FWH 500V: 0.25-30A FWH 0.25-7A: 500V (6 x 32mm) FWH 10-30A: 500V (6 x 32mm) Time-Current Curve Time-Current Curve 104 6 4 FWH-002A6F FWH-3.15A6F 2 10 FWH-005A6F 3 FWH-6.30A6F FWH-007A6F 6 4 2 102 Virtual Pre-Arcing Time In Seconds 6 4 2 101 6 4 2 100 6 4 2 10-1 6 FWH-.250A6F 4 FWH-.500A6F FWH-001A6F 2 10-2 4x10-3 .2 .4 .6 .8 100 2 4 6 8 101 2 4 6 8 102 2 Prospective Current In Amps RMS Data Sheet: 35785256 202 Data Sheet: 50955 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Ferrule -- FWH 500V: 1-30A FWH (14 x 51mm) Specifications Description: Ferrule style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 500Vac/dc Amps: -- 1-30A IR: -- 200kA RMS Sym. -- 50kA @500Vdc Agency Information: CE, UL Recognition 1- 30A & CSA Component Acceptance: 5 - 30A. 2.0 This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. 1.6 Power Losses 300 100 Total Clearing I2t 1.5 K 1.0 Catalog Numbers 0.5 0.3 0.2 0.15 100 Eg 250 400 1.2 103 800 600 500 400 Eg 200 300 400 500 1.0 Kp 0.8 0.6 0.5 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 80 90 100% Electrical Characteristics Rated I2t (A2 Sec) Current Clearing RMS-Amps Pre-arc at 500V 1 -- -- 2 -- -- 3 -- -- 4 -- -- 5 1.6 6.4 6 1.6 6.4 10 3.6 13 12 -- -- 15 10 40 20 26 96 25 49 191 30 58 232 Watts Loss -- -- 2.3 -- 1.5 1.5 4 -- 5.5 6 7 9 * Watts loss provided at rated current. * See accessories on page 216. Dimensions - mm (inches) 50.8 (2.000") 500 Catalog Numbers Size FWH-1A14F FWH-2A14F FWH-3A14F FWH-4A14F FWH-5A14F FWH-6A14F 14 x 51mm FWH-10A14F (916" x 2") FWH-12A14F FWH-15A14F FWH-20A14F FWH-25A14F FWH-30A14F UL High Speed Fuses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Electrical Characteristics The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). Arc Voltage 14.3 (0.563") * * * * Features and Benefits Excellent cycling capability and DC performance Low arc voltage and low energy let-through (I2t) Low watts loss in a compact size Used with finger-safe holders/blocks * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 15.5 (0.610") Data Sheet: 720008 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 203 High Speed Fuses Ferrule -- FWH 500V: 1-30A FWH 1-30A: 500V (14 x 51mm) Time-Current Curve 104 6 4 2 103 6 4 2 Virtual Pre-Arcing Time In Seconds 102 6 4 FWH-5A14F FWH-10A14F FWH-15A14F FWH-20A14F FWH-25A14F FWH-30A14F 2 101 6 4 2 100 6 4 2 10-1 6 4 2 10-2 6 4 2 10-3 6 4 2 10-4 2 4 6 8 101 2 4 6 8 2 102 4 6 8 103 Prospective Current In Amps RMS Peak Let-Through Curve 104 6 4 2 Peak Let-Through Current 10 FWH-30A14F FWH-25A14F 3 6 4 2 FWH-20A14F FWH-15A14F FWH-10A14F FWH-5A14F 102 6 4 2 101 101 2 4 6 2 102 4 6 103 2 4 6 104 2 4 6 105 2 Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785298 204 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Ferrule -- FWC 600V: 6-32A FWC (10 x 38mm) Specifications Description: Ferrule style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 600Vac/dc Amps: -- 6-32A IR: -- 200kA RMS Sym. -- 50kA @ 700Vdc (6-25A) Agency Information: CE, UL Recognition: 6-32A. UL Recognition: 6-25A The total clearing I t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). K 1.0 0.5 Eg 250 400 Dimensions - mm (inches) 38.1 (1.500") 10.3 (0.406") 9.5 (0.375") UL 1.2 103 800 600 500 400 300 200 Eg 300 400 500 600 1.0 Kp 0.8 0.6 0.5 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 80 90 100% Catalog Numbers 0.3 0.2 0.15 100 1.6 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. 1.5 2 This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. High Speed Fuses Total Clearing I t 2.0 Power Losses Electrical Characteristics 2 Arc Voltage 500 600 Catalog Numbers Size FWC-6A10F FWC-8A10F FWC-10A10F FWC-12A10F 10 x 38mm FWC-16A10F (1332" x 112") FWC-20A10F FWC-25A10F FWC-30A10F FWC-32A10F Electrical Characteristics Rated I2t (A2 Sec) Current Clearing RMS-Amps Pre-arc at 600V 6 4 30 8 6 50 10 9 70 12 15 120 16 25 150 20 34 260 25 60 390 30 95 600 32 95 600 Watts Loss 1.5 2.0 2.5 3.0 3.5 4.8 6.0 7.5 7.5 * Watts loss provided at rated current. * See accessories on page 216. * * * * Features and Benefits Excellent cycling capability and DC performance Low arc voltage and low energy let-through (I2t) Low watts loss in a compact size Used with finger-safe holders/blocks * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters Data Sheet: 720011 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 205 High Speed Fuses Ferrule -- FWC 600V: 6-32A FWC 6-32A: 600V (10 x 38mm) Time-Current Curve 104 6 4 2 103 FWC-6A10F FWC-8A10F FWC-10A10F FWC-12A10F FWC-16A10F FWC-20A10F FWC-25A10F FWC-30A10F & FWC-32A10F 6 4 2 102 Virtual Pre-Arcing Time In Seconds 6 4 2 10 1 6 4 2 100 6 4 2 10-1 6 4 2 10-2 6 4 2 10-3 6 4 2 10-4 2 101 4 6 8 102 2 4 6 8 103 6 104 Prospective Current In Amps RMS Peak Let-Through Curve 104 6 FWC-30A10F & FWC-32A10F FWC-25A10F FWC-20A10F FWC-16A10F 4 Peak Let-Through Current 2 10 3 6 4 2 FWC-12A10F FWC-10A10F FWC-8A10F FWC-6A10F 102 6 4 2 10 1 101 2 4 6 102 2 4 6 103 2 4 4 6 105 2 Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785306 206 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Ferrule -- FWP 690V/700V (IEC/UL): 1-50A, Striker Optional FWP (14 x 51mm) Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Power Losses Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1.4 1.2 1.0 0.9 0.8 0.7 0.6 0.5 0.4 K UL 5 4 Eg 3 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Electrical Characteristics 1.4 1.2 103 9 8 7 6 200 300 400 500 600 700 1.0 Kp 0.8 0.6 0.5 High Speed Fuses Specifications Description: Ferrule style high speed fuses with and without indicating striker. Dimensions: See dimensions illustrations. Ratings: Volts: -- 690Vac (IEC) -- 700Vac (UL) FWP with -- 800Vdc (5-50A) striker option. Amps: -- 1-50A IR: -- 200kA RMS Sym. -- 50kA @800Vdc Agency Information: CE, UL Recognition, CSA Component Acceptance for versions without indicator only. 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 80 90 100% Catalog Numbers 1) 2) 0.3 200 Eg 300 400 500 600 700 1) 5-30A Range 2) 32-50A Range Dimensions - mm (inches) Without Striker 50.8 (2.000") 14.3 (0.563") 15.5 (0.610") With Striker 59 (2.323") 51 (2.00") 14.3 (0.563") 5 (0.197") Catalog Numbers Size Without Striker FWP-1A14Fa FWP-2A14Fa FWP-2.5A14Fa FWP-3A14Fa FWP-4A14Fa FWP-5A14Fa 14 x 51mm FWP-10A14Fa (916" x 2") FWP-15A14Fa FWP-20A14Fa FWP-25A14Fa FWP-30A14Fa FWP-32A14Fa FWP-40A14Fa FWP-50A14Fa With Striker FWP-10A14FI FWP-15A14FI FWP-20A14FI 14 x 51mm FWP-25A14FI (916" x 2") FWP-30A14FI FWP-32A14FI FWP-40A14FI FWP-50A14FI Current RMS-Amps Electrical Characteristics Rated I2t (A2 Sec) Minimum Clearing At Watts Melting Rated Voltage Loss 1 2 2.5 3 4 5 10 15 20 25 30 32 40 50 -- -- -- -- -- 1.6 3.6 8.6 26.0 46.5 58 68 84 200 -- -- -- -- -- 11.0 38.5 70 230 375 485 600 750 1800 -- -- -- -- -- 1.5 4 5.5 6 7 9 7.6 8 9 10 15 20 25 30 32 40 50 3.6 8.6 26.0 46.5 58 68 84 200 38.5 70 230 375 485 600 750 1800 4 5.5 6 7 9 7.6 8 9 * Watts loss provided at rated current. * See accessories on page 216. 13 (0.511") * * * * Features and Benefits Excellent cycling capability and DC performance Low arc voltage and low energy let-through (I2t) Low watts loss in a compact size Used with finger-safe holders/blocks Data Sheet: 720025 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 207 High Speed Fuses Ferrule -- FWP 690V/700V (IEC/UL): 1-50A, Striker Optional Without Striker FWP 5-50A: 660V/700V (14x 51mm) Time-Current Curve 104 6 4 2 103 6 4 2 FWP-25A14F FWP-30A14F FWP-32A14F FWP-40A14F FWP-50A14F 102 Virtual Pre-Arcing Time In Seconds 6 4 2 101 6 4 2 100 6 4 FWP-5A14F FWP-10A14F FWP-15A14F FWP-20A14F 2 10-1 6 4 2 10-2 6 4 2 10-3 6 4 2 10-4 2 4 6 8 2 101 4 6 8 2 102 4 6 8 103 6 105 Prospective Current In Amps RMS Peak Let-Through Curve 104 FWP-50A14F FWP-40A14F FWP-32A14F FWP-30A14F FWP-25A14F 6 4 Peak Let-Through Current 2 103 6 4 2 FWP-20A14F FWP-15A14F FWP-10A14F FWP-5A14F 102 6 4 2 101 101 2 4 6 102 2 4 6 103 2 4 6 104 2 4 2 Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785307 208 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Ferrule -- FWP 690V/700V (IEC/UL): 20-100A, Striker Optional FWP (22 x 58mm) Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: Ferrule style high speed fuses with and without indicating striker. Dimensions: See dimensions illustration. Ratings: Volts: -- 690Vac (IEC) -- 700Vac (UL) Amps: -- 20-100A IR: -- 200kA RMS Sym. -- 50kA @ 500Vdc Agency Information: CE, UL Recognition 5 4 Eg 200 Power Losses FWP with striker option. K 300 400 500 600 700 1.0 Kp 0.8 0.6 0.5 High Speed Fuses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Total Clearing I2t 1.4 1.2 1.0 0.9 0.8 0.7 0.6 UL 3 Electrical Characteristics The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1.4 1.2 103 9 8 7 6 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 80 90 100% Catalog Numbers 0.5 0.4 Eg 0.3 200 300 400 500 600 Dimensions - mm (inches) Without Striker 58.0 (2.283") 22.2 (0.875") 15.0 (0.591") Size 22 x 58mm (78" x 2932") 22 x 58mm (78" x 2932") Watts Loss 20 25 32 40 50 63 80 100* 19.0 34.0 53.5 68 135 280 600 1100 260 410 605 750 1600 3080 6600 12500 5 6 8 9 9.5 11 13.5 16 20 25 32 40 50 63 80 100* 19.0 34.0 53.5 68 135 280 600 1100 260 410 605 750 1600 3080 6600 12500 5 6 8 9 9.5 11 13.5 16 *IEC/UL Voltage rating 690/700 With Striker 66 (2.598") 58 (2.283") 5 (0.197") 700 Catalog Numbers Without Striker FWP-20A22Fa FWP-25A22Fa FWP-32A22Fa FWP-40A22Fa FWP-50A22Fa FWP-63A22Fa FWP-80A22Fa FWP-100A22Fa With Striker FWP-20A22FI FWP-25A22FI FWP-32A22FI FWP-40A22FI FWP-50A22FI FWP-63A22FI FWP-80A22FI FWP-100A22FI Electrical Characteristics I2t (A2 Sec) Minimum Clearing At Melting Rated Voltage Rated Current RMS-Amps * * * * Features and Benefits Excellent cycling capability and DC performance Low arc voltage and low energy let-through (I2t) Low watts loss in a compact size Used with finger-safe holders/blocks * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters 16 (0.630" 22.2 (0.874") Data Sheet: 720026 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 209 High Speed Fuses Ferrule -- FWP 690V/700V (IEC/UL): 20-100A, Striker Optional Without Striker FWP 20-100A: 660V/700V (22 x 58mm) Time-Current Curve 104 6 4 2 103 6 4 2 FWP-50A22F FWP-63A22F FWP-80A22F FWP-100A22F 102 6 4 Virtual Pre-Arcing Time In Seconds 2 101 6 4 2 10 0 6 4 FWP-20A22F FWP-25A22F FWP-32A22F FWP-40A22F 2 10-1 6 4 2 10-2 6 4 2 10-3 6 4 2 10-4 2 101 4 6 8 2 102 4 6 8 103 Prospective Current In Amps RMS Peak Let-Through Curve 104 FWP-100A22F FWP-80A22F 6 FWP-63A22F Peak Let-Through Current 4 FWP-50A22F 2 10 3 6 FWP-40A22F FWP-32A22F 4 FWP-25A22F FWP-20A22F 2 102 102 2 4 6 103 2 4 6 104 2 4 6 105 2 Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785291 210 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Ferrule -- FWK 750V: 5-60A FWK 5-30A (20 x 127mm 35-60A (25 x 146mm) Specifications Description: Ferrule style high speed fuses. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 750Vac -- 750Vdc (Time constant = 10-15mS) Amps: -- 5-60A IR: -- 45kA RMS Sym. Agency Information: CE Catalog Numbers Size 20 x 127mm (1316" x 5") 25 x 146mm (1" x 534") Features and Benefits Excellent cycling capability and DC performance Low arc voltage and low energy let-through (I2t) Low watts loss in a compact size Used with finger-safe holders/blocks * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters Electrical Characteristics Rated I2t (A2 Sec) Current Clearing RMS-Amps Pre-arc at 750Vdc 5 8.5 16 8 50 100 10 95 200 15 100 240 20 125 315 25 400 1100 30 800 2600 35 1300 4300 40 1600 5300 50 3100 12000 60 5900 24000 High Speed Fuses Catalog Numbers FWK-5A20F FWK-8A20F FWK-10A20F FWK-15A20F FWK-20A20F FWK-25A20F FWK-30A20F FWK-35A25F FWK-40A25F FWK-50A25F FWK-60A25F * * * * Recommended fuseholders for 20x127, CH127-1, -2, -3 Recommended fuseclips for 20x127, 1A1837 Recommended fuseclips for 25x146, A3354705 Dimensions - mm (inches) Fig. 1: 5-30A 127.0 (5.000") 20.5 (0.807") 16.0 (0.630") Fig. 2: 35-60A 146.05 (5.75") 25.4 (1") 20.64 (0.813") Data Sheet: 720039 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 211 High Speed Fuses Ferrule -- FWK 750V: 5-60A FWK 750V: 5-30A (20 x 127mm) 35-60A (25 x 146mm) Time-Current Curve 104 6 4 FWK-15A20F 2 FWK-20A20F 103 FWK-25A20F 6 FWK-30A20F 4 FWK-40A25F FWK-50A25F 2 FWK-60A25F 10 2 Virtual Pre-Arcing Time In Seconds 6 4 2 101 6 4 2 100 6 4 FWK-5A20F FWK-8A20F 2 FWK-10A20F 10 1 6 4 2 10 2 3 4x10 2 4 6 8 101 2 4 6 8 102 2 4 6 8 103 Prospective Current In Amps RMS Data Sheet: 35785031 212 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Ferrule -- FWJ 1000V: 20-30A FWJ (14 x 67mm) Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: Ferrule style high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: -- 1000Vac/800Vdc Amps: -- 20-30A IR: -- 25kA RMS Sym. -- 20kA @ 800Vdc Agency Information: CE, UL Recognized The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 1.0 800 400 Eg 200 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. K 0.5 0.3 0.2 0.15 200 1200 600 1000 1400 1800 1.0 Kp 0.8 0.6 0.5 High Speed Fuses 1.5 UL 1600 Power Losses Electrical Characteristics Total Clearing I2t 2000 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 80 90 100% Catalog Numbers Eg 500 800 1000 Catalog Numbers FWJ-20A14F FWJ-25A14F FWJ-30A14F Size 14 x 67mm (916" x 258") Electrical Characteristics I2t (A2 Sec) Clearing Pre-arc at 1000V 25 220 33 350 52 450 Rated Current RMS-Amps 20 25 30 Watts Loss 9 11 14 * Watts loss provided at rated current. * See accessories on page 216. Dimensions - mm (inches) 66.7 (2.626") 14.5 (0.571") 15.9 (0.625") * * * * Features and Benefits Excellent cycling capability and DC performance Low arc voltage and low energy let-through (I2t) Low watts loss in a compact size Used with finger-safe holders/blocks * * * * Typical Applications DC common bus DC drives Power converters/rectifiers Reduced voltage starters Fuseclips: * Catalog Number: 5591 (see data sheet 2132) Data Sheet: 720028 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 213 High Speed Fuses Ferrule -- FWJ 1000V: 20-30A FWJ 20-30A: 1000V (14 x 67mm) Time-Current Curve 104 6 4 2 103 6 4 2 102 6 4 Virtual Pre-Arcing Time In Seconds 2 101 6 4 FWJ-20A14F FWJ-25A14F FWJ-30A14F 2 100 6 4 2 10-1 6 4 2 10-2 6 4 2 10-3 6 4 2 10-4 101 2 4 6 8 102 2 4 6 8 103 Prospective Current In Amps RMS Peak Let-Through Curve 104 6 4 FWJ-30A14F FWJ-25A14F FWJ-20A14F Peak Let-Through Current 2 103 6 4 2 102 6 4 2 101 101 2 4 6 102 2 4 6 103 2 4 6 104 2 4 6 105 2 Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785315 214 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa High Speed Fuses Ferrule -- FWS/FWL 1000Vdc: 2-30A FWS 2-15A (20 x 127mm) FWL 20-30A (20 x 127mm) * * * * Specifications Description: Ferrule style full range fuses. Dimensions: See dimensions illustrations. Ratings: Volts: -- 1200Vac (FWL 20-30A) -- 1400Vac (FWS 8-15A) -- 2100Vac (FWS 2-6A) -- 1000Vdc (FWL/FWS 2-30) Amps: -- 2-30A IR: -- 45kA RMS Sym. -- 30kA @ 1000Vdc Agency Information: CE, IEC 60077 Features and Benefits Excellent cycling capability and DC performance Low arc voltage and low energy let-through (I2t) Low watts loss in a compact size Used with finger-safe holders/blocks Typical Applications * DC common bus * DC drives * Power converters/rectifiers * Reduced voltage starters * Traction aux circuits * Capacitor protection High Speed Fuses FWL/FWS 2-30A: 1000Vdc 2-30A (20 x 127mm) Time-Current Curve Catalog Numbers Catalog Numbers FWS-2A20F FWS-6A20F FWS-8A20F FWS-10A20F FWS-12A20F FWS-15A20F FWL-20A20F FWL-25A20F FWL-30A20F Size 20 x 127mm (1316" x 5") 20 x 127mm (1316" x 5") Electrical Characteristics Rated I2t (A2 Sec) Current Clearing RMS-Amps Pre-arc at 1000Vdc 2 0.8 2.4 6 27 81 8 64 192 10 118 277 12 170 380 15 209 500 20 675 1550 25 1200 2760 30 1850 4300 Watts Loss 4.4 6.7 7.6 3.0 3.4 5.0 5.9 6.5 7.5 * ADD "I" to catalog number for indicating version. * Enclosed finger-safe fuse holder - CH127 * Open style fuse block - 4530-OP * See accessories on page 216. * Watts loss provided at rated current. Dimensions - mm (inches) 127.0 (5.000") 20.5 (0.807") 16.0 (0.630") Indicating Version - Dimensions - mm (inches) 8.0 (0.315") 127.0 (5.000") 20.5 (0.807") 2.0 16.0 (0.630") Data Sheet: 720040 2.0 (0.079") For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 215 High Speed Fuses Ferrule Fuse Accessories Fuse Holders Fuse Blocks Specifications Catalog Symbol: CH Series Description: DIN rail mount fuse holders Agency Information: cULus/cURus/CE North American 10 x 38 Class CC: Listed UL 4248, Guide IZLT, File E14853, Certified CSA Std. C22.2 No. 39, Class 6225 01, File 47235 North American 10 x 38 Midget: Recognized UL 4248, Guide IZLT2, File E14853, Certified CSA Std. C22.2 No. 39, Class 6225 01, File 47235 European: 10 x 38 IEC 269-2-1, 14 x 51 IEC 269-2-1, 22 x 58 IEC 269-2-1 Features and Benefits * Finger-safe design - No exposed contacts * DIN rail mount (35mm) - Fits standard mounting rails * Optional open fuse indication lights tells fuse status at a glance * Handle/fusepuller easily installs and removes fuses * Available in single and multi-pole configurations * Wire ready lugs and spade terminal connections save installation time * CE marking * Available up to 1000Vdc * PLC device available for remote monitoring Specifications Catalog Symbol: J70100, J70032 Description: Fuse blocks for 22 x 58mm & 14 x 51mm fuses. Ratings: Volts: -- 700Vac Amps: -- 32-100A Withstand: -- 200kA RMS Sym. Agency Information: CE, UL Recognized, Guide IZLT2, File E14853 Flammability Rating: UL 94V0 Catalog Numbers Catalog Numbers J70032-2CR Fuse Size 14x51 Amps 32 Poles Max Wire Size 2 3 #2 100 1 #2 100 2 #2 100 3 #2 22x58 J70100-3CR Recommended Cooper Bussmann Fuse Types Class CC North American Class CC Fuses - LP-CC, FNQ-R, KTK-R 10 x 38 North American Midget Fuses - FNQ, KTK, AGU, BAF, BAN, FNM, FWA, FWC, PV & DCM 14 x 51 Fuses - FWX, FWH, FWP & NON 22 x 58 Fuses - FWP See pages 257 and 258 for CH Series fuse holder information. 216 Retaining Clip Box Lug w/ Retaining Clip 32 J70100-1CR Typical Applications * Switchboard panel, control consoles, small motors, transformers, and similar applications Data Sheet: 2053 Box Lug w/ J70032-3CR J70100-2CR Data Sheet: 1211 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Terminations #2 IEC & British Standard Fuses IEC and British Standard Fuses Section Contents Application Data Page Application Data . . . . . . . . . . . . . . . . . . . . . 217-218 HRC fuse holders CAMaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235 SAFEloc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235 RED indicates NEW information Supplementary ranges cover applications up to 660Vac and 500Vdc including those with nonstandard tag fixings. Cooper Bussmann fuses are manufactured under quality systems independently assessed to BS 5750 (ISO 9002) and appropriate ratings carry the ASTA 20 endorsement. Selecting fuses is relatively simple and effective. The following notes cover the majority of applications. For further information contact our Application Engineers at 636-527-1270. Circuit Loading The current rating of the fuse should not be less than the full load current of the circuit. The circuit should be so designed that small overloads of long duration will not be of frequent occurrence. Cable Ratings & Protection There is an increasing move away from 70C PVC insulation to materials that are more environmentally friendly, for example 90C XLPE. The ratings of fusegear, switches, accessories, etc. are generally based upon the equipment being connected to conductors intended to be operated at a temperature not exceeding 70C in normal service. In view of the above, it is recommended that the practice of designs based upon conductor temperatures of 70C be regarded as the norm. The equipment manufacturer should be consulted to ascertain the reduction of nominal current rating of the equipment if conductor temperatures exceeding 70C are used. In addition, an overriding factor is often voltage drop. Fuses with gG characteristics protect associated cables against both overload and short-circuit current, provided that the current rating of the fuse 1N is equal or less than the current carrying capacity of the cable 1z. In motor circuits, the motor starter will provide the overload protection and the fuses will provide the short-circuit protection. The maximum fuse size that can be used depends upon the type of cable used and is determined using the appropriate K factor. The following table gives the maximum sizes of fuses that are recommended for two popular cables with copper conductors, 70C PVC (K = 115) and 90C thermosetting (K = 143). For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 217 IEC & British Fuses CSA Type P and Type D fuses (CDS, CDN & PON) . . . . . . . . . . . . . . . . . . . . . . . . . . . .219 Tron(R) HRC Form II Class C fuses (CGL Form II Class C) . . . . . . . . . . . . . . . . . . . . . . . . . . 220 HRCI Industrial ceramic body fuses (CIF21 HRCI-CA & CIF06 HRCI-CB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 HRCI-J Fast-acting fuses (CJ HRCI-J) . . . . . . . . . . . . . . . 222 HRCI-Miscellaneous Type K fuses (CIH, CIK & CIL HRCI-MISC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 HRC Form II current-limiting fuses . . . . . . . . . . . . . . . . . .224 BS 88 British Standard low voltage fuses (SSD, NSD, ESD & STD, NITD, AAO, BAO, OSD, CEO, DEO BS 88 Part 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225 BS 88 British Standard low voltage fuses (AC, AD, BC, BD, CD, DD, ED, EFS & EF, FF, FG, GF, GG, GH BS 88) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226 DIN Style Type D (D16, D27, D33, D125 Type D) . . . . . . 227 Neozed low voltage fuses (NZ01, NZ02 Type D0) . . . . . . 227 NH HRC Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228-231 Class gG/gL IEC Industrial ferrule fuses (C08G, C08M, C10G, C10M, C14G, C14M, C22G, C22M) . . . . . . . . . . 232 Class aM IEC Industrial ferrule fuses (C08M, C10M, C14M, C22M) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233 Class aM & gG/gL IEC Industrial ferrule fuses with striker (C14G_S, C22G_S, C14M_S, C22M_S) . . . . . . . . . . . . . 234 The standard range of fuses for low voltage industrial and general purpose applications meet the requirements of BS 88 and IEC 60269. By using advanced fuse technology, current ratings up to 400A have compact dimensions, but retain standard dimensional and performance requirements. These designs are for 315/240V systems. The standard range of fuses are available from 2-1250A in the following tag forms: Offset Blade - Offset Bolted - Center Bolted. IEC & British Standard Fuses Application Data for BS Low Voltage Fuses Cable Size (mm2) 1 1,5 2.5 4 6 10 16 25 35 50 70 95 120 Max. Fuse Rating (amps) K = 115 K = 143 16 16 20 25* 32* 32* 50* 50* 63* 63* 100* 125* 125* 160* 200* 250* 315* 355* 400* 500 560 630 710 800 800 1000 * Extended Motor Circuit dual ratings can be used. Protection Against Electrical Shock For a TN System, a disconnecting time not exceeding 5s is permitted for a distribution circuit. The maximum values of earth fault loop impedance (Zs) of 240V for Cooper Bussmann gG fuses to BS 88: Parts 2 and 6 are: Rating (A) Zs (Ohms) Rating (A) Zs (Ohms) Rating (A) Zs (Ohms) 6 14 50 1.1 250 0.16 10 7.7 63 0.86 315 0.13 16 4.3 80 0.60 400 0.096 20 3.0 100 0.44 500 0.073 25 2.4 125 0.35 630 0.054 32 1.9 160 0.27 800 0.044 40 1.4 200 0.20 Ambient Temperature The derating, in terms of current, of 0.5% per C above an ambient of 35C is recommended. Capacitor Circuits For power factor correction in capacitor circuits, the fuse should be chosen with a current rating greater than 1.5 times the rated capacitor current. This takes into account the high inrush current, circuit harmonics and capacitor tolerances. Motor Circuits In motor circuits, the fuse has to withstand the motor's starting current and often requires a higher rating than the motor's full load current. Coordination recommendations are made by the manufacturers of motor starters in accordance with IEC 60947-4-1. To get Type 2 coordination with fuses, tests are performed with the latest gG or gM fuses to BS 88 or IEC 60269 that have pre-arcing I2t values towards the bottom of specified limits. This means that Cooper Bussmann fuses are suitable to provide Type 2 coordination. Extended dual ratings of motor circuit protection fuses with gM characteristics are available in most popular fuse sizes to extend the use of associated equipment with appropriate economies. In the majority of applications, gG fuses are used. It is not essential to use gM fuses for motor circuit protection, they simply extend the utilization of standard equipment. Below is a table of recommended fuses at 415V. In most applications, the run-up time is less than 5 seconds and duty is infrequent - no more than twice per hour. The next larger rating should be used for more demanding applications. Interrupting Rating The standardized interrupting rating values are 80kA for voltages of 415Vac and above, and 40kA for DC applications. The 240Vac designs have an interrupting rating of 50kA. Coordination Ratio All fuses to BS 88 Parts 2 and 6 will give a coordination ratio of 2:1; and for most practical situations a ratio of 1.6:1 (two steps in the R10 series). Example: an upstream fuse rated at 160A will coordinate with a downstream fuse rated at 100A. Current and Energy Limitation The range of fuses have pre-arcing I2t values towards the bottom limits of BS 88 Parts 2 and 6. This ensures excellent current and energy limitation. They also have lower power losses at rated current. This assists in the appropriate interchangeability with other makes of fuses. Transformers When fuses are used on the primary side of transformers, the normal fuse current rating should be at least twice the nominal transformer primary current. Fluorescent Lighting The normal fuse current rating should be at least twice the normal full load current of the maximum number of lights to be simultaneously switched. 218 kW 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 18.5 22.0 30.0 37.0 45.0 55.0 75.0 90.0 110.0 132.0 150.0 185.0 200.0 225.0 250.0 280.0 335.0 355.0 Rating Motor A 0.8 1.1 1.5 2.0 30 3.6 5.0 6.5 8.4 11.0 15.0 20.0 27.0 33.0 38.0 54.0 66.0 79.0 98.0 135.0 155.0 185.0 220.0 250.0 310.0 335.0 375.0 415.0 460.0 562.0 596.0 Direct On-line Standard Motor Circuit (gG) (gM) A A 4 4 6 6 10 16 16 20 20 25 20M25 40 32M40 50 32M50 63 32M63 80 63M80 80 63M80 100 63M100 125 100M125 160 100M160 160 100M160 250 200M250 250 200M250 315 200M315 355 315M400 355 315M400 450 400M500 500 4 00M500 560 560 630 710 800 - For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Asst. Start Standard (gG) A 2 2 4 4 6 01 01 61 61 2 20 25 32 40 50 50 80 80 100 100 160 160 200 250 315 355 400 400 450 500 630 710 IEC & British Standard Fuses CSA Type P and Type D Fuses CDS, CDN & PON Type P & D Specifications Description: CSA time-delay Type D & P fuses. Dimensions: See Catalog Numbers table and Dimensions illustration. Ratings: Volts: -- 250Vac (CDN & PON) -- 600Vac (CDS) Amps: -- 10-600A IR: -- 10kA minimum Agency Information: CE, CSA Certified to C22.2 No. 59.1. Features and Benefits * Economical fuse in a variety of ratings for applications not requiring time-delay. Dimensions A IEC & British Fuses Typical Applications * Lighting, heating and other circuits not subject to temporary surges and where available short-circuit current are relatively low. B Basic Catalog Numbers Ferrule Design--1 through 60A Time-Delay CSA Type "D" Fuses Catalog Numbers CDN CDS Amp Ratings Below 10A use FRN-R 10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 110, 125, 150, 175, 200, 225, 250, 300, 350, 400, 450, 500, 600 Below 10A use FRS-R 10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250, 300, 350, 400, 450, 500, 600 Volts 250Vac 600Vac C A D B F E Knife Blade--70 through 600A One-Time CSA Type "P" Fuses Catalog Number PON Amp Ratings 15, 20, 25, 30, 35, 40, 45, 50, 60 Volts 250Vac Catalog Numbers Basic Catalog Number and Volts CDN/PON 250Vac CDS 600Vac Amp Ratings 1-30 35-60 70-100 110-200 225-400 450-600 1-30 35-60 70-100 110-200 225-400 450-600 A Overall 2.0 (50.8) 3.0 (76.2) 5.88 (149.4) 7.3 (185.4) 8.63 (219.2) 10.38 (263.7) 5.0 (127.0) 5.5 (139.7) 7.88 (200.2) 9.63 (244.6) 11.63 (295.4) 13.38 (339.9) B Max Diameter 0.56 (14.3) 0.81 (20.6) -- -- -- -- 0.81 (20.6) 1.06 (27.0) -- -- -- -- Dimensions in (mm) C Min D Min Blade Length Barrel Length -- -- -- -- 1.0 (25.4) -- 1.38 (34.9) 4.13 (104.8) 1.88 (47.6) 4.63 (117.5) 2.25 (57.2) 5.19 (131.8) -- -- -- -- 1.0 (25.4) -- 1.38 (34.9) 6.13 (115.6) 1.88 (47.6) 7.13 (118.1) 2.25 (57.2) 8.19 (208.0) E Blade Thickness -- -- 0.13 (3.2) 0.19 (4.8) 0.25 (6.4) 0.25 (6.4) -- -- 0.13 (3.2) 0.19 (4.8) 0.25 (6.4) 0.25 (6.4) F Blade Width -- -- 0.75 (19.1) 1.13 (28.6) 1.63 (41.3) 2 (50.8) -- -- 0.75 (19.1) 1.13 (28.6) 1.63 (41.3) 2 (50.8) To Order To order, specify Basic Catalog Number and amp rating. Example: CDN-30 Data Sheet: 4126 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 219 IEC & British Standard Fuses Tron(R) HRC Form II Class C Fuses CGL Form II Class C Specifications Description: Current-limiting HRCII-C fuses designed to withstand inrush currents on typical motor start-ups while offering high current limitation in the short-circuit region. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 600Vac/250Vdc (1-30A) Amps: -- 1-600A IR: -- 200kA (40,000A DC) Agency Information: CE, CSA Certified, C22.2 No. 106. Dimensions 0.22" 0.81" 0.22" (20.64mm) (5.56mm) (5.56mm) 0.06" 2.0" (1.59mm) 0.34" (50.8mm) 2.80" 0.94" (8.73mm) (23.81mm) (71.04mm) 3.31" (84.14mm) CGL 1-30 0.22" 0.81" 0.22" (20.64mm) (5.56mm) (5.56mm) 0.06" 2.0" (50.8mm) (1.59mm) 0.50" 2.80" 1.06" (12.7mm) (71.04mm) (26.92mm) 3.5" (88.9mm) Features and Benefits * Close sizing to loads allows using smaller and less costly switches * Provides a higher degree of short-circuit protection * Helps protect motors against burnout from overloads CGL 35-60 0.343" 0.343" (8.71mm) (8.71mm) 2.39" Typical Applications * For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads (60.72mm) 3.64" 1.34" (34.04mm) 0.09" (2.29mm) 0.75" 1.375" (19.05mm) (34.93mm) (92.47mm) 4.31" (109.54mm) CGL 70-100 Catalog Numbers (-Amps) CGL-1 CGL-2 CGL-3 CGL-4 CGL-6 CGL-10 CGL-15 CGL-20 CGL-25 CGL-30 CGL-35 CGL-40 CGL-45 CGL-50 CGL-60 CGL-70 CGL-80 CGL-90 CGL-100 CGL-110 CGL-125 CGL-150 CGL-175 CGL-200 CGL-225 CGL-250 CGL-300 CGL-350 CGL-400 CGL-450 CGL-500 CGL-600 0.343" (8.71mm) 0.343 (8.71mm) 0.125" 3.00" (3.18mm) 0.75" (76.2mm) (19.05mm) 4.30" (109.22mm) 1.50" (38.1mm) 5.31" (134.87mm) CGL 110-200 0.19" (4.76mm) 1.0" 0.38" (25.4mm) (9.53mm) 1.0" (25.4mm) 3.0" 2.38" (76.2mm) (60.33mm) 5.25" (133.35mm) 8.19" (207.96mm) CGL 225-400 1.0" 0.41" (25.4mm) (10.32mm) 1.0" (25.4mm) .60" 3.0" (15.24mm) (76.2mm) 5.25" (133.35mm) 8.19" (207.96mm) CGL 450-600 Data Sheet: 4125 220 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 0.375" (9.53mm) 3.00" (76.2mm) IEC & British Standard Fuses HRCI Industrial Ceramic Body Fuses CIF21 HRCI-CA CIF06 HRCI-CB Specifications Description: The HRCI-CA fuse provides both overload and short-circuit protection to HRCI requirements. Offset blades for bolt-on mounting. CIF21 fuse fits the Cooper Bussmann CAMaster fuse holder (see data sheet 4132). Dimensions: See Dimensions illustration. Construction: Ceramic body. Ratings: Volts: -- 600Vac/250Vdc Amps: -- 1-30A IR: -- 200kA RMS Sym. Agency Information: CE, CSA C22.2, No. 106-M92. Mounting: Bolt-on. Specifications Description: A miniature industrial fuse that provides both short-circuit and overload protection and the CIF06 fits the 30A SAFEloc fuse holder. Dimensions: See Dimensions illustration. Construction: Ground ceramic body with plated end caps. Ratings: Volts: -- 600Vac/250Vdc Amps: -- 1-30A IR: -- 200kA RMS Sym. Agency Information: CE, CSA C22.2 No. 106-M92 (3-30A only). Mounting: Clip-in offset blades. Catalog Numbers Catalog Number Amp Ratings 1 3 6 10 15 20 25 30 Catalog Numbers 1CIF06 3CIF06 6CIF06 10CIF06 15CIF06 20CIF06 25CIF06 30CIF06 Features and Benefits * Close sizing to loads allows using smaller and less costly switches * Provides a higher degree of short-circuit protection * Helps protect motors against burnout from overloads Typical Applications * For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads IEC & British Fuses Catalog Numbers 1CIF21 3CIF21 6CIF21 10CIF21 15CIF21 20CIF21 25CIF21 30CIF21 Amp Ratings 1 3 6 10 15 20 25 30 Features and Benefits * Close sizing to loads allows using smaller and less costly switches * Provides a higher degree of short-circuit protection * Helps protect motors against burnout from overloads Typical Applications * For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads Dimensions - in (mm) Dimensions - in (mm) 2.15 (54.5) 1.44 (35.5) 0.19 (4.7) 0.54 (13.8) 2.38 (60.4) 1.44 (35.5) 0.44 (11.1) 0.54 (13.8) 0.5 (12.7) 0.03 (3.5) 1.75 (44.5) Data Sheet: 4127 0.03 (0.81) 0.14 (3.5) Data Sheet: 4128 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 221 IEC & British Standard Fuses HRCI-J Fast-acting Fuses Dimensions CJ HRCI-J Specifications Description: HRCI-J fast-acting fuses are industrial duty fuses with the excellent current-limiting characteristics of fast-acting HRCI-J fuses to limit damage to equipment and installations by the thermal and magnetic energy associated with a large short-circuit fault current. Overload characteristics limit cable damage due to low overload currents. Dimensions: See Catalog Numbers table and Dimensions illustrations. Construction: Ceramic body fuse. Ratings: Volts: -- 600Vac (or less), 250Vdc Amps: -- 1-600A IR: -- 200kA Agency Information: CSA C22.2 No. 106 M92; Designed to BS 88:2, IEC 60269-2. 1CJ to 60CJ A B B C 70CJ to 600CJ E J C A K F H D B G Catalog Numbers Catalog Numbers Catalog Numbers 1CJ 3CJ 6CJ 10CJ 15CJ 20CJ 25CJ 30CJ 35CJ 40CJ 45CJ 50CJ 60CJ 70CJ 80CJ 90CJ 100CJ 110CJ 125CJ 150CJ 175CJ 200CJ 225CJ 250CJ 300CJ 350CJ 400CJ 450CJ 500CJ 600CJ Amp Ratings 1 3 6 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150 175 200 225 250 300 350 400 450 500 600 Dimensions in (mm) A B C D E F G H J K 2.25 (57) 0.5 (12.7) 0.81 (20.6) -- -- -- -- -- -- -- 2.38 (60) 0.63 (16) 1.06 (27) -- -- -- -- -- -- -- 4.63 (117) 3.63 (92) 1.13 (28) 0.75 (19) 0.13 (3.2) 1 (25.4) 0.5 (12.7) 0.28 (7.1) 0.38 (9.5) 2.63 (67) 5.75 (146) 4.38 (111) 1.63 (41) 1.13 (28.6) 0.19 (4.8) 1.38 (35) 0.69 (17.5) 0.28 (7.1) 0.38 (9.5) 3 (76) 7.13 (181) 5.25 (133) 2.13 (54) 1.63 (41) 0.25 (6.3) 1.88 (47.6) 0.94 (24) 0.41 (10.3) 0.53 (13.5) 3.38 (86) 8 (203) 6 (152) 2.63 (66) 2 (51) 0.38 (9.5) 2.13 (54) 1 (25.4) 0.53 (13.5) 0.69 (17.5) 3.75 (96) Data Sheet: 4129 222 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa IEC & British Standard Fuses HRCI - Miscellaneous Type K Fuses CIH, CIK & CIL HRCI-MISC Specifications Description: HRI fuses provide both overload and short-circuit protection, featuring offset blades for bolt down mounting. Dimensions: See Catalog Numbers table and Dimensions illustration. Construction: Ceramic body. Ratings: Volts: -- 600V Amps: -- 1-100A IR: -- 200kA@600V Agency Information: CE, CSA C22.2 No. 106 M92. Dimensions G J E IEC & British Fuses K F A D B L C H G (The CIL14 has a rejection hole, not a slot as shown above.) Catalog Numbers Catalog Amp Numbers Ratings 1CIH07 1 3CIH07 3 6CIH07 6 10CIH07 10 15CIH07 15 20CIH07 20 25CIH07 25 30CIH07 30 35CIK07 35 40CIK07 40 50CIK07 50 60CIK07 60 80CIL14 80 90CIL14 90 100CIL14 100 A Max 2.25 (57) B Max 0.94 (24) C Max 3.38 (86) D Nom 0.38 (9.2) Dimensions: in (mm) E Nom F Nom G Nom 0.04 (1.0) 2.88 (73) 0.21 (5.2) 2.25 (57) 0.94 (24) 3.38 (86) 0.38 (9.2) 0.04 (1.0) 2.28 (58) 1.06 (27) 3.56 (91) 0.5 (12.7) 0.05 (1.2) 2.28 (58) 1.06 (27) 3.56 (91) 0.5 (12.7) 0.05 (1.2) 2.75 (70) 2.75 (70) 1.44 (37) 1.44 (37) 4.38 (111) 4.38 (111) 0.75 (19) 0.75 (19) 0.09 (2.5) 0.09 (2.5) 3.69 (94) 3.69 (94) 2.88 (73) H Nom 0.31 (8) J Max 1 (25.4) K Nom 0.10 (2.6) L Max 2.38 (60) 1 (25.4) 0.10 (2.6) 2.38 (60) 0.21 (5.2) 0.31 (8) 2.88 (73) 0.21 (5.2) 0.41 (10.5) 1.09 (28) 0.13 (3.2) 2.38 (61) 2.88 (73) 0.21 (5.2) 0.41 (10.5) 1.09 (28) 0.13 (3.2) 2.38 (61) 0.34 (8.7) 0.34 (8.7) 0.41 (10.5) 0.41 (10.5) 1.5 (38.5) 1.5 (38.5) -- 2.91 (74) 2.91 (74) -- Recommended Fuse Holders Fuse 1-30A 35-60A Fuse Holder CM30CF CM60CF Data Sheet: 4130 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 223 IEC & British Standard Fuses HRC Form II Current-limiting Fuses Dimensions HRC Form II F Specifications Description: HRC Form II current-limiting fuses. Dimensions: See Catalog Numbers table and Dimensions illustrations. Construction: Ceramic body. Ratings: Volts: -- 600Vac (or less) -- 250Vdc Amps: -- 2-600A IR: -- 200kA RMS Sym. Agency Information: CE, CSA C22.2 No.106M1992; BS 88:2, IEC 60269:2. G J A D E H C F J E A G D B C C B A H G E K K F B A G P11C/R11C (Center Blades) D H E C Catalog Numbers 1.38 (35) L09C/M09C/P09C (Center Blades) D F A 1.38 (35) B 0.56 (14) 0.56 (14) C 3.38 (85) 3.38 (85) D 0.38 (9) Dimensions in (mm) E F 0.06 (1.2) 2.88 (73) G 0.22 (5.6) H 0.31 (8) 0.38 (9) J K 0.56 (14) -- 0.56 (14) CSA Category HRCII-C -- HRCII-C 3.44 (87) 3.44 (87) 0.06 (1.2) 2.88 (73) 0.22 (5.6) 0.31 (8) 0.5 (13) 0.06 (1.2) 2.88 (73) 0.22 (5.6) 0.31 (8) 2.19 (56) 0.88 (22) 2.19 (56) 2.19 (56) 0.88 (22) 0.88 (22) 3.75 3.75(95) (95) 0.5 (13) 0.5 (13) 0.06 (1.2) 2.88 (73) 0.22 (5.6) 0.31 (8) 2.38 2.38 (60) (60) 0.88 (21.4) (21.4) 0.88 4.38 (111) 0.56 (14.3) (14.3) 0.56 0.13 (3.2) (3.2) 0.13 3.69 (94) 0.34 (8.7) 2.56 (65) 2.56 (65) 1.5 (38) 1.5 (38) 4.38 (111) 0.75 (19) 0.75 (19) 0.09 (2.4) 0.09 (2.4) 3.69 (94) 0.34 (8.7) 2.38 2.38 (60) (60) 0.88 (21.4) (21.4) 0.88 5 5(127) (127) 0.56 0.56 (14) (14) 0.13 (3.2) 4.38 (111) 0.34 (8.7) 2.56 (65) 2.56 (65) 1.5 (38) 1.5 (38) 5.38 (136) 0.75 (19) 0.75 (19) 0.13 0.13 (3.2) (3.2) 4.38 (111) 0.34 (8.7) 0.34 (8.7) 3.06 (178) 2.31 (59) 5.38 (136) 1 (25.4) 0.19 (4.8) 4.38 (111) 4.38 (111) 0.34 (8.7) 3.19 (81) 3.19 (81) 2.31 (59) 2.31 (59) 2.88 (73) 2.88 (73) 8.25 (210) 8.25 (210) 8.25 (210) 1 (25.4) 1 (25.4) 0.19 (5) 1 (25.4) 0.25 (6.3) 0.25 (6.3) HRCII-MISC HRCII-MISC 0.44 (11) 11 (25.4) (25.4) ---- HRCII-C HRCII-C 0.44 (11) 0.44 (11) -- -- -- HRCII-MISC -- 0.44 (11) ---- ---- HRCII-MISC HRCII-MISC 0.56 (14) 0.56 (14) -- -- -- HRCII-C HRCII-C 0.5 (13) -- -- 0.5 (13) 0.19 (4.8) 3.06 (178) 3.06 (178) 0.88 (22) -- -- 0.88 (22) 0.88 (22) -- -- 5.25 (133) 0.41 (10) 0.63 (16) 5.25 (133) 5.25 (133) 0.41 (10) 0.41 (10) 0.63 (16) 0.63 (16) For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa -- -- -- 0.19 (5) Data Sheet: 4131 224 K07C/K07CR/ L14C/M14C (Offset Blades) H Typical Applications * Used to protect motor control circuits, together with contactors and overload protection relays to provide Type 2 coordination - per IEC 60947-4. Catalog Amp Numbers Ratings 2H07C 2 4H07C 4 6H07C 6 10H07C 10 15H07C 15 20H07C 20 25H07C 25 30H07C 30 40K07C 40 50K07C 50 60K07C 60 80K07CR 80 100K07CR 100 80L14C 80 100L14C 100 125M14C 125 150M14C 150 200M14C 200 80L09C 80 100L09C 100 125M09C 125 150M09C 150 200M09C 200 250P09C 250 300P09C 300 350P09C 350 400P09C 400 250P11C 250 300P11C 300 350P11C 350 400P11C 400 450R11C 450 500R11C 500 600R11C 600 H07C (Offset Blades) B -- 1 (25) -- 1 (25) -- 1 (25) 1 (25) -- HRCII-C HRCII-MISC HRCII-MISC HRCII-C HRCII-C HRCII-C IEC & British Standard Fuses BS 88 British Standard Low Voltage Fuses SSD, NSD, ESD BS 88 Part 1 Specifications Description: The NSD and ESD are low voltage fuses complying with general purpose gG characteristics. Construction: Ceramic body. Ratings: Volts: -- 240-550Vac (See Catalog Numbers table) Amps: -- 2-63A (See Catalog Numbers table) -- 20M25-63M100A Motor Starter ratings (See Catalog Numbers table) IR: -- 33kA (SSD) -- 80kA (NSD, ESD) Agency Information: CE, Meets the requirements of BS 88 Part 1 and IEC 60269-1. Mounting: Offset blades. ESD Amp Ratings 2, 4, 6, 10, 16, 20, 25, 32 2, 4, 6, 10, 16, 20, 25, 32, 20M25*, 20M32*, 20M36*, 32M36*, 32M40*, 32M50*, 32M63* 2, 4, 6, 10, 16, 25, 32 40, 50, 63, 63M80, 63M100* Max AC Voltage Ratings 240 550 415 415 550 415 BS 88 Ref. E1 F1 F1 F1 F2 F2 *"M" indicates motor starter ratings. To Order To order, specify Basic Catalog Number and amp rating. Example: SSD-20 Recommended Fuse Holders Basic Fuse Catalog Numbers NSD ESD Holder Catalog Numbers 32NNSF 63ENSF Specifications Description: The STD to DEO types are low voltage fuses complying with general purpose gG characteristics. Construction: Ceramic body. Ratings: Volts: -- 240-550Vac (See Catalog Numbers table) Amps: -- 2-200A (See Catalog Numbers table) -- 20M25-200M315A Motor Starter ratings (See Catalog Numbers table) IR: -- 33kA (STD) -- 80kA (NITD, AAO, BAO, CEO, DEO) Agency Information: CE, Meets the requirements of BS 88 Part 1 and IEC 60269-1. Mounting: Offset bolted blades. IEC & British Fuses Basic Catalog Numbers Basic Catalog Numbers SSD NSD STD, NITD, AAO, BAO, OSD, CEO, DEO BS 88 Part 1 Typical Applications * The STD type are used in 240V street lighting cut-outs. * NITD to DEO types used for industrial and general purpose applications Basic Catalog Numbers Basic Catalog Numbers STD NITD AAO BAO CEO DEO OSD Amp Ratings 2, 4, 6, 10, 16, 20, 25, 32 2, 4, 6, 10, 16, 20, 25, 32 20M25*, 20M32*, 32M40*, 32M50*, 32M63* 2, 4, 6, 10, 16, 20, 25, 32, 32M40*, 32M50*, 32M63* 40, 50, 63, 63M80*, 63M100* 32, 40, 50, 63, 80, 100 100M125*, 100M160*, 100M200* 125, 160, 200, 200M250*, 200M315* 80, 100 100M125*, 100M160* Max AC Voltage BS 88 Ratings Ref. 240 -- 550 -- 415 -- 550 -- 550 A3 550 A4 415 A4 415 -- 550 -- 415 -- *"M" indicates motor starter ratings. To Order To order, specify Basic Catalog Number and amp rating. Example: BAO-16 Recommended Fuse Blocks & Holders Basic Fuse Catalog Numbers NITD AAO BAO OSD CEO Data Sheets 4105 (SSD), 4100 (NSD) and 4101 (ESD) Block/Holder Catalog Numbers CM32FC CM32F CM63F CM100F BH-0111 Data Sheets 4123 (STD), 4106 (NITD), 4109 (AAO), 4112 (BAO), 4107 (OSD), 4115 (CEO) and 4117 (DEO) For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 225 IEC & British Standard Fuses BS 88 British Standard Low Voltage Fuses AC, AD, BC, BD, CD, DD, ED, EFS BS 88 Specifications Description: Low voltage fuses that comply with general purpose gG characteristics and available up to 400A with two hole mount and up to 1250A with four hole mount. Construction: Ceramic body. Ratings: Volts: -- 415/550Vac, 250Vdc (See Catalog Numbers table) Amps: -- 2-400A (See Catalog Numbers table) -- 63M80-400M500A Motor Starter ratings (See Catalog Numbers table) IR: -- See Catalog Numbers table Agency Information: CE, Meets the requirements of BS 88 Parts 1 and 2 and IEC 60269-1. Mounting: Center bolted blades, two-hole mount. Specifications Description: Low voltage fuses complying with general purpose gG characteristics and available up to 400A with two hole mount and up to 1250A with four hole mount. Construction: Ceramic body. Ratings: Volts: -- 415/550Vac, 250/400Vdc (See Catalog Numbers table for details) Amps: -- 355-1250 IR: -- See Catalog Numbers table Agency Information: CE, Meets the requirements of BS 88 Parts 1 and 2 and IEC269-1. Mounting: Center bolted blades, four-hole mount. Basic Catalog Numbers Basic Catalog Numbers Basic Catalog Numbers AC AD BC BD CD DD ED EFS Amp Ratings 2, 4, 6, 10, 16, 20, 25, 32 2, 4, 6, 10, 16, 20, 25, 32 40, 50, 63 63M80*, 63M100* 40, 50, 63 80, 100, 100M125*, 100M160*, 100M200*, 100M200* 125, 160, 200, 200M250*, 200M315* 250, 315, 355, 400, 315M400* 400M500* 125, 160, 200, 250, 315 Interrupting Ratings AC DC 80kA 40kA 80kA 40kA 80kA 40kA 80kA -- 80kA 40kA 80kA -- Max Voltage Ratings BS 88 AC DC Ref. 550 250 -- 550 250 -- 550 250 -- 550 -- -- 550 250 -- 415 -- EF, FF, FG, GF, GG, GH BS 88 B1 80kA -- 415 -- B2 80kA 80kA 80kA -- -- 415 550 415 -- -- -- B3 B4 -- Basic Catalog Numbers EF Interrupting Max Voltage Amp Ratings Ratings BS 88 Ratings AC DC AC DC Ref. 355, 400 80kA -- 415 -- C1 400M500* 80kA -- 550 -- -- FF 450, 500, 560, 630 80kA 40kA 550 400 C2 FG 450, 500, 560, 630 80kA 40kA 550 400 -- GF 710, 800 80kA 40kA 550 250 C3 GG 710, 800 80kA 40kA 550 250 -- 1000, 1250 80kA -- 550 -- -- GH 710, 800, 1000, 1250 80kA -- 550 -- -- *"M" indicates motor starter ratings.*"M" indicates motor starter ratings. To Order To order, specify Basic Catalog Number and amp rating. Example: FG-450 *"M" indicates motor starter ratings. To Order To order, specify Basic Catalog Number and amp rating. Example: BC-40 Recommended Fuse Blocks & Holder Basic Fuse Catalog Numbers AC AD BC BD CD DD ED Block/Holder Catalog Numbers BH-0111 Modular fuse block 200DF Fuse holder BH-0111 Modular fuse block 200DF Fuse holder 200DF Fuse holder 200DF Fuse holder BH-1131 Modular fuse block Data Sheets 4110 (AC), 4111 (AD), 4113 (BC), 4114 (BD), 4116 (CD), 4118 (DD), 4119 (ED) and 4121 (EFS) 226 Data Sheets 4120 (EF), 4102 (FF), 4122 (FG), 4103 (GF), 4104 (GG) and 4108 (GH) For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa IEC & British Standard Fuses DIN Style Type D and Neozed Low Voltage Fuses D16, D27, D33, D125 Type D NZ01, NZ02 Type D0 Specifications Description: DIN style Type D low voltage fuses. Dimensions: See Catalog Numbers table and Dimensions illustrations. Construction: Ceramic body. Ratings: Volts: -- 500Vac Amps: -- 2-100A IR: -- 100kA Agency Information: CE, "D" type fuses complying with DIN 49360 Part 2 and DIN 49515, operating class gL. Catalog Numbers Amp Ratings 2 4 6 10 16 20 25 2 4 6 10 16 20 25 35 50 63 80 100 Dimension "D" (mm) 6 6 6 8 10 12 14 6 6 6 8 10 12 14 16 18 20 5 7 Color Code Pink Brown Green Red Grey Blue Yellow Pink Brown Green Red Grey Blue Yellow Black White Copper Silver Red Figure Number 1 2 Catalog Numbers 2NZ01 4NZ01 6NZ01 10NZ01 16NZ01 20NZ02 25NZ02 35NZ02 50NZ02 63NZ02 Amp Ratings 2 4 6 10 16 20 25 35 50 63 Dimension "D" (mm) 11 11 11 11 11 15 15 15 15 15 Color Code Pink Brown Green Red Grey Blue Yellow Black White Copper IEC & British Fuses Catalog Numbers 2D16 4D16 6D16 10D16 16D16 20D16 25D16 2D27 4D27 6D27 10D27 16D27 20D27 25D27 35D33 50D33 63D33 80D125 100D125 Specifications Description: Low voltage Neozed fuses suitable for use on 250Vdc systems. Dimensions: See Catalog Numbers table and Dimensions illustration. Construction: Ceramic body. Ratings: Volts: -- 400Vac Amps: -- 2-63A IR: -- 100kA Agency Information: CE Catalog Numbers Dimensions (mm) D 3 4 36 Additional Fuselinks: Quick acting fuselinks in body sized D16, D27, D33 and D125 rated 2-100A. Reference number suffixed Q, i.e. 10D27Q. Voltage rating 500V. Gauge rings and keys can also be supplied. Dimensions (mm) Figure 1 Figure 2 Data Sheet: 4124 Figure 3 Figure 4 Data Sheet: 4124 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 227 IEC & British Standard Fuses NH HRC Fuses ___NHG___B Ratings: Volts: -- 500Vac/250Vdc -- 690Vac/250Vdc Amps: -- 2-1250A IR: -- 120kA Frequency: -- 50Hz Operating Frequency: -- 45-62Hz Agency Information: IEC 60269, VDE0636, DIN 43620 Part 1 to 4, VDE Mark and CE. Specifications Class: gG/gL Description: DIN square bodied, dual indication industrial fuses. Construction: Steatite insulator, corrosionproof (aluminum) metal parts with full-contact, silver-plated copper blades. Sizes: DIN 000 to 4. Selectivity Ratio: 1:1.6 up to 500Vac. Fuse Blocks SB00-D SB1-D SB2-D Size 000-00 1*, 1 02, 2, 03, 3 Dimensions (mm) Fuse Size 000 00 0 01 1 02 2 03 3 4 a1 78.5 1.5 78.5 1.5 125 2.5 135 2.5 135 2.5 150 2.5 150 2.5 150 3 150 3 200 a2 (max) 54 54 68 75 75 75 75 75 75 84 45 45 62 62 62 62 62 62 62 80 a3 1.5 1.5 +3/-1.5 2.5 2.5 2.5 2.5 2.5 2.5 a4 49 1.5 49 1.5 68 +1.5/-3 68 2.5 68 2.5 68 2.5 68 2.5 68 2.5 68 2.5 90 b (nom) 15 15 15 15 20 20 25 25 32 50 c1 ( 8) 35 35 35 40 40 48 48 60 60 85 c2 (nom) 10 11 11 11 11 11 11 11 11 11 D (nom) 2 0.5 7.0 0.5 2.5 0.5 2.5 0.5 2.5 0.5 2.5 0.5 2.5 0.5 2.5 0.5 3.0 0.5 3 e1 (max) 41 48 48 48 53 53 61 61 75 120 e2 (max) 21 30 30 30 52 52 60 60 70 87 e3 (max) 16 25 25 25 25 25 25 25 25 -- Data Sheet 4173 228 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com e4 (nom) 6 6 6 6 6 6 6 6 6 8 f (max) 8 15 15 15 15 15 15 15 18 30 IEC & British Standard Fuses NH HRC Fuses 500Vac / 250Vdc Size 000 00 01 1 02 2 03 3 4 Single Indicator Slotted End Tags 2 4 6 10 16 20 25 32 35 40 50 63 80 100 125 160 10 16 20 25 32 35 40 50 63 80 100 125 160 10 16 20 25 32 35 40 50 63 80 100 125 160 200 224 250 35 40 50 63 80 100 125 160 200 224 250 315 355 400 250 315 355 400 500 630 500 630 800 1000 1250 gG/gL Dual Indicator Voltage Conducting Carton Metal Gripping Lugs Quantity 2NHG000B 4NHG000B 6NHG000B 10NHG000B 16NHG000B 20NHG000B 25NHG000B 32NHG000B 35NHG000B 40NHG000B 50NHG000B 63NHG000B 80NHG000B 100NHG000B 125NHG00B 160NHG00B 10NHG0B 16NHG0B 20NHG0B 25NHG0B 32NHG0B 35NHG0B 40NHG0B 50NHG0B 63NHG0B 80NHG0B 100NHG0B 125NHG0B 160NHG0B 10NHG01B 16NHG01B 20NHG01B 25NHG01B 32NHG01B 35NHG01B 40NHG01B 50NHG01B 63NHG01B 80NHG01B 100NHG01B 125NHG01B 160NHG01B 200NHG1B 224NHG1B 250NHG1B 35NHG02B 40NHG02B 50NHG02B 63NHG02B 80NHG02B 100NHG02B 125NHG02B 160NHG02B 200NHG02B 224NHG02B 250NHG02B 315NHG2B 355NHG2B 400NHG2B 250NHG03B 315NHG03B 355NHG03B 400NHG03B 500NHG3B 630NHG3B 500NHG4G 630NHG4G 800NHG4G 1000NHG4G 1250NHG4G 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 1 1 1 1 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com IEC & British Fuses 0 Rated Current (Amps) 229 IEC & British Standard Fuses NH HRC Fuses 690Vac / 250Vdc Size 000 00 0 1 2 3 230 Rated Current (Amps) 2 4 6 10 16 20 25 32 35 40 50 63 80 100 6 10 16 20 25 32 35 40 50 63 80 100 50 63 80 100 125 160 200 63 80 100 125 160 200 224 250 315 250 315 355 400 425 500 gG/gL Dual Indicator Voltage Conducting Carton Metal Gripping Lugs Quantity 2NHG000B-690 4NHG000B-690 6NHG000B-690 10NHG000B-690 16NHG000B-690 20NHG000B-690 25NHG000B-690 32NHG000B-690 35NHG000B-690 40NHG000B-690 50NHG00B-690 63NHG00B-690 80NHG00B-690 100NHG00B-690 6NHG0B-690 10NHG0B-690 16NHG0B-690 20NHG0B-690 25NHG0B-690 32NHG0B-690 35NHG0B-690 40NHG0B-690 50NHG0B-690 63NHG0B-690 80NHG0B-690 100NHG0B-690 50NHG1B-690 63NHG1B-690 80NHG1B-690 100NHG1B-690 125NHG1B-690 160NHG1B-690 200NHG1B-690 63NHG2B-690 80NHG2B-690 100NHG2B-690 125NHG2B-690 160NHG2B-690 200NHG2B-690 224NHG2B-690 250NHG2B-690 315NHG2B-690 250NHG3B-690 315NHG3B-690 355NHG3B-690 400NHG3B-690 425NHG3B-690 500NHG3B-690 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com IEC & British Standard Fuses NH Fuse Bases SB*-D, SB*-S Up to 690V / 160 - 1250A Sizes 00, 0, 1, 2, 3, 4 Part Numbers Size Poles 00 Current (Amps) 1 3 160A Part Numbers DIN Screw Carton Compatible Quantity Fuse Size SB00-D TB00-D 3 1 000 & 00 Description: NH fuse bases with thermoplastic bodies. DIN rail and screw mounting (size 4 screw fix). Range of protection accesories for live parts in order to obtain IP20 protection standard. 0 1 3 160A SB0-D TB0-D 3 1 0 1 1 3 250A SB1-D TB1-D 3 1 01 & 1 Ratings: 2 1 3 400A SB2-D TB2-D 3 1 02 & 2 3 1 3 630A SB3-D TB3-D 3 1 03 & 3 4 1 1250A SB4-S (Screw Connection only) 3 4 * Voltage: up to 690Vac * Amps: 2 to 1250A Applications: Protection of industrial circuits and electrical apparatus TB00-D-IP20 Standards and Approvals: IEC 60269, DIN 43620 Size Current (Amps) Part Ref NH00 160 SL00 NH0 160 SL0 NH1 250 SL1 NH2 400 SL2 NH3 630 SL3 NH4 1000 SL4 IEC & British Fuses Neutral Carton Quantity 3 Fuse extraction handle Size Part Ref Carton Quantity C00-3 FEH 1 Protection accessories Size Current (Amps) NH00* NH0 NH1 NH2 NH3 160A 160A 250A 400A 630A Separation Partition 4 Fuse Casing 5 Terminal Cover 1 Separator 3 Part Ref Carton Quantity Part Ref Carton Quantity Part Ref Carton Quantity Part Ref Carton Quantity SP00* SP0 SP1-2 SP1-2 SP3 2 2 2 2 2 FC00* FC0 FC1-2 FC1-2 FC3 3 3 3 3 3 CS00* CS0 CS1 CS2 CS3 6 6 6 6 6 BC00* BC0 BC1-2 BC1-2 BC3 2 2 2 2 2 * For single pole only IP Protection Kits Microswitch Part Reference Description TB00-D-IP20 Complete triple pole fuse base IP20 rated FPK0-3P IP20 kit for TB0-D fuse base FPK1-3P IP20 kit for TB1-D fuse base FPK2-3P IP20 kit for TB2-D fuse base FPK3-3P IP20 kit for TB3-D fuse base Part Ref Carton Quantity BVL-50 1 Microswitch suitable for the following NH Fuse links: - 400 Volts gG/gL - 500 Volts gG/gL and aM - 690 Volts gG/gL and aM For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 231 IEC & British Standard Fuses Class gG/gL IEC 60269 Industrial Ferrule Fuses 8 x 31mm: 400Vac, 0.5 - 25A 10 x 38mm: 500Vac, 0.5 - 32A 14 x 51mm: 400Vac - 500Vac - 690Vac, 1 - 50A 22 x 58mm: 400Vac - 500Vac - 690Vac, 2 - 125A 232 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com IEC & British Standard Fuses Class aM IEC Industrial Ferrule Fuses - Class aM IEC 60269 8 x 31mm: 400Vac, 1 - 8A 10 x 38mm: 400Vac - 550Vac, 0.16 - 25A IEC & British Fuses 14 x 51mm: 690Vac - 500Vac, 0.25 - 50A 22 x 58mm: 400Vac - 500Vac - 690Vac, 2 - 125A Neutral Links For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 233 IEC & British Standard Fuses Class aM & gG/gL IEC Industrial Ferrule Fuses with Striker Class gG/gL with Striker 14 X 51 22 X 58 Catalog Number With Striker C14G2S C14G4S C14G6S C14G8S C14G10S C14G12S C14G16S C14G20S C14G25S C14G32S C14G40S C14G50S Catalog Number With Striker C22G4S C22G6S C22G8S C22G10S C22G12S C22G16S C22G20S C22G25S C22G32S C22G40S C22G50S C22G63S C22G80S C22G100S C22G125S Amp Rating 2 4 6 8 10 12 16 20 25 32 40 50 Amp Rating 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 Watts Loss (W) 0.24 0.45 0.42 0.70 0.53 0.88 1.16 1.23 1.46 2.04 3.34 3.04 Watts Loss (W) 0.48 0.47 0.73 0.74 0.83 1.21 1.29 1.53 2.13 3.40 3.48 4.46 5.86 6.61 8.42 Voltage (AC) 500 500 400 Voltage (AC) 690 Interrupting Rating (kA) 120 120 Interrupting Rating (kA) 80 690 80 500 500 120 120 400 Class aM with Striker 14 X 51 22 X 58 234 Catalog Number With Striker C14M1S C14M2S C14M4S C14M6S C14M8S C14M10S C14M12S C14M16S C14M20S C14M25S C14M32S C14M40S C14M50S Catalog Number With Striker C22M2S C22M4S C22M6S C22M8S C22M10S C22M12S C22M16S C22M20S C22M25S C22M32S C22M40S C22M50S C22M63S C22M80S C22M100S C22M125S Amp Rating 1 2 4 6 8 10 12 16 20 25 32 40 50 Amp Rating 2 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 Watts Loss (W) 0.14 0.24 0.45 0.42 0.70 0.53 0.88 1.16 1.23 1.46 2.04 3.34 3.04 Watts Loss (W) 0.29 0.48 0.47 0.73 0.74 0.83 1.21 1.29 1.53 2.13 3.40 3.48 4.46 5.86 6.61 8.42 Voltage (AC) 500 500 400 Voltage (AC) 690 Interrupting Rating (kA) 120 120 Interrupting Rating (kA) 80 690 80 500 500 400 120 120 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com IEC & British Standard Fuses HRC Fuse Holders SAFEloc Specifications Catalog Symbol: See table below. Description: The CAMaster HRC fuse holder features a unique cam-action for easy fuse removal while allowing significantly improved contact pressure between fuse carrier and base contact that enhances electrical performance. A range of lockable safety carriers for the fuse holder (catalog reference: LSC), are available. Ratings: Volts: -- 690V Amps: -- 30-100A (See Catalog Number table for details) Agency Information: CE, CSA C22.2 No. 39; IEC 269 AND BS 88. Mounting: 35mm DIN-rail or single screw mounting. Specifications Catalog Symbol: See table below. Description: The SAFEloc HRC fuse holders (for use with HRCI-CB fuses) provides a positive, stressfree fuse fitting and locks it in position to ensure safe insertion and withdrawal from the base. Base contacts are fully shrouded to help protect against electric shock. Shrouds utilize simple slide/snap action allowing access to the contact terminal screws. Ratings: Volts: -- 600V Amps: -- 30-60A (See Catalog Number table for details) Agency Information: CE, Designed to accommodate the compact range of offset blade fuse to CSA C22.2 No. 106, HRCI-CB. Mounting: 35mm DIN rail or single screw mounting. Catalog Numbers Catalog Numbers CM20CF CM30CF CM60CF CM100CF Amp Ratings 30 30 60 100 Details For: HRCI-CA Applications HRCII Applications Fuse Accepted _CIF21 _H07C _K07C _K07CR Accessory Catalog Numbers for CAMaster Units Catalog Numbers 20BS 32BS 60/100BS GLP NI 20LSC 30LSC 60/100LSC Amp Ratings 30 30 60/100 All All 30 30 60/100A Data Sheet: 4132 Details Back Stud Ganging Link Kit 660V Neon Indicator Security Carrier with Clip Fuse Holder Accepted CM20CF CM30CF CM60/100CF 3-Pole -- CM20CF CM30CF CM60/100CF Catalog Numbers* Catalog Amp Numbers Ratings Connection C30F Front C30BS 30 Back C30FBS Front-Back C60F Front C60BS 60 Back C60FBS Front-Back *For use with HRCI-CB Fuses. Fuse Accepted _CIF06 EK-Amp Data Sheet: 4133 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 235 IEC & British Fuses CAMaster 236 Quik-SpecTM Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards . . . . . . . . . 238-239 Quik-Spec Power Module Switches and Panels . . 240-241 Quik-Spec DC Safety Switches . . . . . . . . . . . . . . . . . . 242 Quik-Spec Solar Combiner Boxes . . . . . . . . . . . . . 243-244 Quik-Spec AC Safety Switches . . . . . . . . . . . . . . . 245-246 A/C Disconnects - Fused and Non-Fused . . . . . . . . . . .247 RED indicates NEW information Quik-SpecTM Electrical Gear 237 Quik-Spec TM Electrical Gear Quik-SpecTM Coordination Panelboard The Quik-Spec Coordination Panelboard Makes Selective Coordination Easy...up to 400A Mains and 100A Branches!* Easy-to-Spec * The Quik-Spec Quik-QuoteTM online configurator makes specifying, pricing and ordering simple, fast and virtually error free. Just log in, select the ratings, features and options you want, and instantly get back pricing for any Coordination Panelboard possible. Contact your Cooper Bussmann representative for access. Saves Time * Enclosure ships within one week of order so installation can start fast. Interior with fuses ships later for jobsite installation. Spare fuses included with chassis shipment so replacements are always on hand. * Specify Quik-Ship when you order and your product will ship within 10 business days. Available on all NEMA 1 enclosure configurations - just make sure your Cooper Bussmann representative knows you want Quik-Ship. Flexible Configurations - Up to 600Vac/400 Amp/200kA SCCR, or 125Vdc/400 Amp/100kA SCCR** * 30, 60, 100, 200, 225 and 400A main ratings * 125Vdc rating ideal for utility and petro-chem control circuits or UPS circuits * 1 to 100 amp fuse ratings to closely match loads * Available in fused or non-fused main disconnect switch, or MLO (Main Lug Only) configurations with a choice of 18, 30 and 42 branch positions, up to 100A, in NEMA 1 or 3R enclosures to easily meet branch or service panel installations needs * Feed through lugs or fused loadside disconnect available Same Size Footprint as Traditional, Circuit Breaker Panelboards * 20" W x 5" D x various heights (depending on configuration) Addresses NEC(R) Selective Coordination Requirements * This cULus Listed panelboard makes it easy to provide systems that comply with NEC(R) Selective Coordination Requirements*** for Emergency, Legally Required Standby, Healthcare Essential Electrical and Critical Operation Power Systems (COPS) per 700.27, 701.18, 517.26 and 708.54. * Full fuse-system selective coordination is easy from source to branch. Just follow published fuse selective coordination ratios - no need for plotting time-current curves or expensive studies. Data Sheet: 1159 238 Increases Safety * Utilizes the finger-safe Low-Peak(R) CUBEFuse(R) in a sizerejecting Compact Circuit Protector (CCPB) base. Fuse interlock prevents removing fuse while energized. Fuse ampacity rejection feature coincides with standard fuse size and copper conductor ampacities to help prevent overfusing. * UL 98 branch circuit disconnect-rated CUBEFuse(R) Compact Circuit Protector Base with fuse ampacity-rejection feature breaks at 15A, 20A, 30A, 40A, 50A, 60A, 70A, 90A and 100A * Local open fuse indication on branch circuit device and optional indicating CUBEFuse * Lockout/Tagout provision eases OSHA compliance * Lock-On provision helps meet requirements for emergency circuits * High fuse interrupting rating and up to 200kA assembly SCCR ratings easily exceed most available fault current levels to help assure compliance with NEC(R) 110.9 and 110.10. Current-limitation of a fused solution also reduces arc-flash hazards and minimizes damage to equipment and circuits. Quik-Ship - 10 Business Day Shipment * All configurations of the standard enclosure Quik-Spec Coordination Panelboard are available for shipment within 10 business days of order. Consult factory for details. *70A, 90A and 100A branch disconnects available for a bus rating 225A or higher. **125Vdc rating applicable to 40 amp or less CCPBs on MLO panels only. ***When used in a fully fused distribution system. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Quik-Spec TM Electrical Gear Quik-SpecTM Coordination Panelboard Coordination Panelboard Specifications Mains: * * * Assembly SCCR: * Voltage Rating: * Bus Ampacity: * Branch Circuits: * * * Panel: * * * * Ground: * Enclosure Size: * Spare Fuses: Options: * * * Depending on configuration ** 125Vdc rating applicable to 40 amp or less CCPBs on MLO panels only. *** Top feed not available on NEMA 3R enclosure ****Flush mount and Door-in-Door not available with NEMA 3R enclosure Data Sheet: 1159 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 239 Quik-SpecTM Electrical Gear Through-Lugs & * Loadside * Disconnect: Neutrals: * MLO (Main Lug Only) Fused Disconnect Switch Non-fused Disconnect Switch 200kA, 100kA or 50kA AC, 100kA or 20kA@125Vdc* Applicable on any 600Vac or less, or 125Vdc** or less systems 400A, 225A, 200A, 100A, 60A or 30A Circuits; Up to 18, 30 and 42* Amps; Up to 100A Type; 1-, 2- and 3-Pole Feed; Top & Bottom*** Mounting; Surface or Flush**** Door/Trim; Regular or Door-inDoor**** NEMA Ratings; 1 & 3R. Other ratings available. Consult factory. Feed-Through - single and double Fused loadside disconnect, _100A> _<200A (400A panels only) 200A and 400A Unbonded and Bonded Non-Isolated or Isolated Standard size panelboard (20" W x 5 D x various heights)* Six-fuse spare fuse compartment Surge Protection Device (TVSS) for high and low energy transients. Quik-Spec TM Electrical Gear Quik-SpecTM Power Module -- All-in-one Elevator Disconnect PS & PMP Cooper Bussmann(R) Quik-Spec Power Module Specifications Description: Fusible power switch or panel with shunt trip and fire safety interface to allow for single point tie in with fire alarm system. Ratings: Volts: -- 600Vac, 3O Amps: -- 30-400A (PS) -- 30-200A (PMP feeder switches) -- 400-800A (PMP main switches*) Assembly SCCR:-- 200,000A rms Typical Applications: * Elevator Disconnects * Computer Room Shunt Trip Disconnect * Fire Safety Interface Relay Accessories: * For added safety, use the Cooper Bussmann(R) SAMITM fuse covers to improve maintenance personnel protection (OSHA 1910.333, paragraph C) Ordering: The Cooper Bussmann Quik-SpecTM Power Module Switch and Panel are factory configured to the specific application. Contact your Cooper Bussmann representative to place your order. Have all relevant electrical and circuit information on hand. *Contact Cooper Bussmann for applications greater than 800A. Agency Information: Complies with NFPA 70 (NEC(R); National Electrical Code(R)), * Elevator Shutdown - ANSI/ASME A17.1, 2.8.3.3.2 - NEC(R) 620.51(B) (Elevator Shutdown) - NEC(R) 240.12 (Orderly Shutdown) * Shunt Trip Voltage Monitoring - NFPA 72, 6.16.4.4 * Selective Coordination - NEC(R) 620.62 * Auxiliary Contact (Hydraulic Elevator) - NEC(R) 620.91(C) PS* The Quik-SpecTM Power Module Switch (PS) for single elevator applications. -- Power Module Switch (PS); UL Listed (UL 98) Enclosed and Dead front switch Guide 96NK3917, File E182262, NEMA 1, UL 50 Listed enclosure**, cUL per Canadian Standards C22.2, No. 0-M91-CAN/CSA C22.2, No. 4-M89 Enclosed switch. **NEMA 12, 3R, and 4 enclosures also available -- Power Module Panel (PMP); UL 98 Enclosed and Deadfront Switches. PMP* Power ModuleTM Panel (PMP) for multiple elevator applications. Features and Benefits: * Internally powered, relay activated shunt trip system * Mechanically interlocked auxiliary contact * Self-contained adherence to elevator consensus standards, NFPA 70 (NEC(R)). NFPA 72, ANSI/ASME 17.1 * Shunt trip capability * Selective coordination * Fire safety signal interface * Shunt trip voltage monitoring * Component protection via Cooper Bussmann(R) Low-Peak(R) Class J fuses * UL 98 Listed for 200kA short-circuit current rating * Lockable in the open position with three-lock capability * Optional key-test switch and optional pilot light for easy inspection * No annual calibration or testing of overcurrent protection required * Padlockable for service-work safety and open-door *Fused main disconnect requires Class J fuses, not supplied with switch. "override" for troubleshooting 240 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Quik-Spec TM Electrical Gear Quik-SpecTM Power Module -- All-in-one Elevator Disconnect Hydraulic Elevators Hydraulic elevators need battery backup to help prevent stranding passengers. To keep the elevator from moving when it's been manually shut down for maintenance, the NEC(R) requires battery backup be connected to the elevator disconnecting means through an auxillary contact. However, an unintended consequence can be passengers getting stranded because of devices that open automatically (circuit breakers and disconnects utilizing a Battery Lowering Required Yes Scenario Power failure Fire in shaft or machine room Disconnect manually opened Fault on loadside of disconnect No No molded case switch with a trailing fuse block) will operate with a fault on their loadside. That operation also disables the battery backup and strands passengers. That's why the Power Module has a non-automatic fusible shunt trip switch. If the Power Module has a fault on its loadside, the fuses open and the battery stays enabled. Thus the Power Module ensures that battery power is enabled when the passengers need it to exit - and disabled to allow safe maintenance of the elevator and hoistway. Reason Need to lower elevator to allow passengers to exit. Recall is initiated by smoke detector and lowers elevator to a safe floor. Battery not needed. Worker to perform maintenance. Elevator must remain stationary to prevent injury. Need to lower elevator to allow passengers to exit. Offered By Power ModuleTM Yes Offered By Other Elevator Disconnects Yes Yes Yes Yes Yes Yes No Yes Quik-SpecTM Power Module Switch Catalog Numbering System PS 1 T48 R1 K G N1 B F1 U Key Test Switch Control Transformer* Prefix T20 T24 T48 T60 PS = Power Module Switch = = = = 208 240 480 600 Volt Volt Volt Volt K = Key Ampere Rating Fire Safety Interface Relay (3PDT, 10A, 12V) 3 6 1 2 4 R1 = 120Vac Coil R2 = 24Vdc Coil = = = = = 30A 60A 100A 200A 400A Neutral Lug N6 N1 N2 N4 = = = = Pilot Light ON G = Green R = Red W = White 30-60A 100A 200A 400A Fire Alarm Voltage Monitoring Relay (To Monitor Shunt Trip Voltage) F1 = Single-Pole F3 = Three-Pole** Auxiliary Contacts B = 2 NO/NC Enclosure Options (TYPE 1 Standard With No Suffix Designation Required) U = TYPE 3R Z = TYPE 12 Y = TYPE 4X Stainless *100Va with Primary and Secondary fusing (120V Secondary) **Only for use with R1 option Required Equipment Quik-Ship Program: Switch - 3 Days, Panel - 10 Days! Ship-direct service within three business days for Power Module Switches (PS_) and 10 business days for Power Module Panels (PMP_). * Three day PS_ shipment requires ordering from catalog numbers shown. ** 10 Day PMP_ shipment covers NEMA 1 enclosures with the ampacities shown and all requirements for relay type (AC or DC), accessory options and number of switches. To order PMP_, contact your Cooper Bussmann representative with all relevant electrical and circuit information, we do the rest. Power Module Switch* Cat Numbers Amps PS6T48R1KGBF3-X 60A PS1T48R1KGBF3-X 100A PS1T20R1KGBF3-X 100A PS2T48R1KGBF3-X 200A PS2T20R1KGBF3-X 200A For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Power Module Panel** Volts Cat. Numbers Amps 480V PMP-400-X 400A 480V PMP-600-X 600A 208V PMP-800-X 800A 480V 208V 241 Quik-Spec TM Electrical Gear Quik-SpecTM DC Safety Switch Isolating DC Circuits Has Never Been Easier or Safer * Flexibility of Application * Enhanced Finger-Safe Design * Meets UL and NEC(R) Requirements NEC 690.17 Compliant Label Warns that the switch terminals may be energized in the open position * Flange Handle Operation * Current-Limiting Fuses Reduce Arc Flash Hazard High Visibility Padlockable Handle Visible Switch Contacts Door Interlock Easy to operate with gloves and up to three padlocks to protect maintenance personnel Positive visual identification of switch state Prevents opening door while energized, but can be manually overridden for testing or inspection. Clear Polycarbonate Deadfront Covers energized parts to provide added protection against electrical hazards. Lineside stays in place during fuse servicing. Fused Version For Added Protection Fuse clips located on switch center pole to ensure both clips are de-energized in OFF position. Meets NEC(R) Article 690.16 that requires isolating the fuse from all potential supply sources. Cooper Bussmann recommends using the Limitron(R) fast-acting, current limiting PVS-R Class RK5 fuse (order separately.) NEMA 3R, 12 & 4X Enclosures Meet many application requirements. 3R and 4X stainless steel well suited for isolating outdoor solar power installations Conduit Knockouts For easy conductor installation Type 3R Dimensions Amps 30 60 100 200 A B C 16.35 8.87 9.89 16.35 8.87 9.89 22.15 11.84 9.89 28.27 16.66 11.26 Main Lug Capacity Neutral Lug Capacity ISC #2 AWG - #14 AWG Al/Cu #2 AWG- #14 AWG Al/Cu 1/0 AWG- #14 AWG Al/Cu 250kcmil - #6 AWG Al/Cu #4 AWG - #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu #2 AWG - #14 AWG Al/Cu 19.2 38.4 64.0 128.0 Dimensions - in Type 12 & 4X Dimensions Amps A 30 & 60 Non-fusible 30 & 60 Fusible 100 200 B C Main Lug Capacity Neutral Lug Capacity ISC 14.14 8.76 10.22 #2 AWG - #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 19.2 19.08 8.76 10.22 #2 AWG - #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 19.2 24.95 11.79 10.22 1/0 AWG- #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 64.0 35.38 16.95 11.63 250kcmil - #6 AWG Al/Cu #2 AWG - #14 AWG Al/Cu 128.0 DC Safety Switch Catalog Numbering System Use this build-a-code to specify the exact Quik-Spec DC Safety Switch you need. BD 1 Voltage BD = Heavy Duty DC Safety Switch 6 = 600Vdc Poles 1 = 1-Pole 242 6 Prefix 1 F R Type F = Fusible with neutral N = Non-fusible with neutral Amps 1 = 30A 2 = 60A 3 = 100A 4 = 200A Enclosure Type R = NEMA 3R D = NEMA 12 W = NEMA 4X Stainless For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Typical Wiring Diagram Fused Non-Fused Line Line Neutral Neutral Load Load Quik-Spec TM Electrical Gear Quik-SpecTM Solar Combiner Boxes BCBS Series Standard Combiner Boxes and BCBD Series with Integrated Disconnect BCBC Series Compact Box BCBS Series Standard Box * * * * * * * * * 4 to 24 Input circuits ETL Listed to UL1741 Standard DCM** or KLM*** 600Vdc midget fuses for overcurrent protection Finger-safe Cooper Bussmann modular fuse holders**** Finger-safe power distribution blocks***** Continuous duty rated at 600Vdc Configured for both positive and negative grounded arrays Single or dual 90C output terminals Steel or fiberglass NEMA 3, 3R, 4 or 4X rated enclosures with seamless door gaskets * Negative Input Terminal Blocks * All products are assembled in the USA With Integrated Disconnect Only * 28, 55, 75, 150 and 245A Integrated disconnects BCBC Series Compact Combiner Boxes BCBD Series Integrated Disconnect Box Number of Input Circuits Input Conductor Range Number of Output Conductors Output Conductor Range Max Fuse Size Max Rated Current (DC Continuous) NEMA Enclosure Ratings Enclosure Dimensions (in), Weight 2 to 4 6-14AWG 1 6-14AWG 30A 76A 4X 6.5x6.5x4, 4 lbs 5 to 6 6-14AWG 1 6-14AWG 30A 76A 4X 6.5x9.5x4, 4 lbs 2 to 6 Input circuits Continuous duty rated at 600Vdc DCM** or KLM*** 600Vdc midget fuses for overcurrent protection Finger-safe Cooper Bussmann modular fuse holders**** ETL Listed to UL1741 Standard NEMA 4X Polycarbonate enclosure Ground blocks included External mounting feet included Quik-SpecTM Electrical Gear BCBC Series Compact Combiner Box Specifications* * * * * * * * * BCBS Series Standard Combiner Box* Number of Input Circuits Input Conductor Range Number of Output Conductors Output Conductor Range Max Fuse Rating Max Rated Current (DC Continuous) Max Voltage NEMA Enclosure Ratings Steel Enclosure Dimensions (in), Weight Fiberglass Enclosure Dimensions (in), Weight 4 to 12 4-16AWG 1 350kcmil-6AWG 30A 310A 600Vdc 3, 3R, 4, 4X 16x12x6, 30 lbs 16x14x7,18 lbs 16 4-16AWG 1 or 2 350kcmil-6AWG 30A 400A 600Vdc 3, 3R, 4, 4X 16x16x6, 36 lbs 22x18x9, 22 lbs 20 to 24 4-16AWG 1 or 2 350kcmil-6AWG 30A 400A 600Vdc 3, 3R, 4, 4X 20x20x6, 46 lbs N/A/NA * Refer to next page for part number configuration. ** See Data Sheet 2038 for details. *** See Data Sheet 2020 for details. **** See Data Sheet 2053 for details. ***** See Data Sheet 1049 for details. BCBD Series Combiner Box with Integrated Disconnect* Disconnect Rating (Amps) Number of Input Circuits Input Conductor Range Number of Output Conductors Output Conductor Range Max Fuse Size Max Rated Current (DC Continuous) Max Voltage NEMA Enclosure Ratings 28A 4 4-14AWG 1 2/0-14AWG 30A 28A 600Vdc 4, 4X 55A 4 4-14AWG 1 2/0-14AWG 30A 55A 600Vdc 4, 4X 75A 4 to 12 4-14AWG 1 350kcmil-6AWG 30A 75A 600Vdc 3, 3R, 4, 4X Steel Enclosure Dimensions (in), Weight 12x10x6, 15 lbs 12x10x6, 15 lbs 20x20x6, 42 lbs Fiberglass Enclosure Dimensions (In), Weight 14x12x7, 12 lbs 14x12x7, 12 lbs 22x18x8, 28 lbs 150A 4 to 24 4-14AWG 1 350kcmil-6AWG 30A 150A 600Vdc 3, 3R, 4, 4X 20x20x6, 50 lbs, or 20x24x6, 50 lbs 24x20x10, 35 lbs, or 24x24x10, 35 lbs 245A 4 to 24 4-14AWG 1 350kcmil to 6AWG 30A 245A 600Vdc 3, 3R, 4, 4X 24x24x6, 55 lbs 24x24x10, 40 lbs Data Sheet: 2054 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 243 Quik-Spec TM Electrical Gear Quik-SpecTM Solar Combiner Boxes Cooper Bussmann Solar Combiner Box Catalog Numbering System Example: BCBD28-24-30R = B C B D 2 8 - 2 4 - 3 0 R ____ ___ __ __ _ Series Prefix BCBS - Combiner Box BCBD - Combiner Box with Integrated Disconnect BCBC - Compact Combiner Box Disconnect Ampacity For ordering BCBD Series only - otherwise, leave blank 28 55 75 150 245 Number of Poles Available (by Series) BCBS & BCBD Series: 04 08 12 16 20 24 BCBC Series: 02 03 04 05 06 Fuse Size (amps)* 00 - No Fuses Included 01 03 05 08 10 15 25 02 04 06 09 12 20 30 * When fuses are specified, DCM or KLM 600Vdc fuses are included Enclosure R - NEMA 3/3R 4 - NEMA 4 (Powder Coated Steel) F - NEMA 4X (Fiberglass) P - NEMA 4X (Polycarbonate)** **BCBC Only available with NEMA 4X (P) option Typical Combiner Box Layouts Standard BCBS Series Integral Disconnect on BCBD Series Compact BCBC Series 4 to 24 Circuits - BCBS-12-00F Pictured 4 to 24 Circuits - BCBD245-24-00R Pictured 2 to 6 Circuits - BCBC-4-00P Pictured 244 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Quik-Spec TM Electrical Gear Quik-SpecTM Safety Switch Cooper Bussmann(R) Quik-SpecTM Safety Switch Utilizing the Cooper Bussmann Class CF Low-Peak CUBEFuse, the Quik-Spec Safety Switch provides Class J fuse performance characteristics that can help mitigate incident energy and arc-flash hazard, and offers excellent component protection. The Cooper Bussmann CUBEFuse requires no tools to install or replace. * * * * * Features and Benefits: * Enhanced Finger-Safe Design The Cooper Bussmann Class CF CUBEFuse isolates live electrical parts from accidental contact to increase safety. Large line-side shield is standard in all models virtually eliminating accidental contact with live parts. * Current-Limiting Fuses Reduce Arc-Flash Hazard with Class J fuse performance characteristics, the Quik-Spec Safety Switch offers industry best arc-flash protection versus traditional models. * Meets UL and NEC(R) Requirements The Quik-Spec Safety Switch is rated 200kA which makes it easier to comply with NEC(R) 110.9 and 110.10 requirements and is listed to UL 98 and UL 50 standards. * Flange Operated Handle Always in contact with the switch mechanism, the flange operated switch is preferred in most industries. * Easy Interface with Viewing Window Option Window provides visual verification that switch contacts have operated, plus the ability to view fuse indication without opening the switch door. * No Tools Required for Fuse Removal Reduce downtime and potential arc-flash hazard. * Flexibility of Application The 600V heavy-duty safety switch is available up to 100A with NEMA 1, 3R, 12 and 4X enclosures. Dimensions - inches (mm)* NEMA 1 & 3R Agency Information: UL 98 standard for enclosed deadfront switches. UL 50 standard for enclosures for electrical equipment. NEMA KS 1. UL Listed, File E5239. cUL Listed to C22.2 No.4-M89. Standard Features: * Extended line terminal shield and finger-safe 30, 60, or 100A Cooper Bussmann CUBEFuse * 200kA short-circuit current rating * Visible double break quick-make, quick-break rotary blade mechanism * Triple padlocking capability * Mechanically interlocked door * 600Vac/250Vdc maximum *See Data Sheet 1156 for 4X and 12 dimension information For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 245 Quik-SpecTM Electrical Gear Specifications Description: The new Cooper Bussmann(R) Quik-SpecTM Safety Switch equipped with finger-safe Low-Peak(R) CUBEFuse(R) provides superior safety and reliability for industrial customers. Optional Features: * Viewing window for visible blades and open fuse indication * NEMA 1, 3R, 12, 4X (stainless) * Suitable for use as service equipment (with neutral kit) Quik-Spec TM Electrical Gear Quik-SpecTM Safety Switch High Visibility Handle Easy to operate with gloves Visible Switch Contacts Positive identification of switch state Padlockable Handle With up to three padlocks to protect maintenance personnel Door Interlock Prevents opening door while energized, but can be manually overridden for testing or inspection Large Line-Side Shield Covers energized parts to provide added protection against electrical hazards CUBEFuse(R) * Class CF (Class J) time-delay electrical performance. * easyIDTM fuse indication option to quickly determine fuse condition * Finger-safe test points allow testing voltage without exposure to energized conductors * Eliminates the need for reducers Conduit Knockouts For easy installation NEMA 1, 3R, 12 & 4X Enclosures Meet most application requirements Quik-SpecTM Safety Switch Catalog Numbering System CF 3 6 1 F G K W Fusible Voltage Switch Type 6 =600Vac CF =Heavy Duty (R) CUBEFuse Safety Switch Poles 3 = 3-Pole Series F = Fusible N =Fusible with Neutral* Amp 1 = 30A 2 = 60A 3 = 100A *Suitable for service entrance use with neutral kit installed. K = Switch Window W = Window Enclosure Type G= R= D= W= NEMA 1 NEMA 3R NEMA 12 NEMA 4X Stainless Maximum Horsepower Ratings System 3-Pole 246 Amp Rating 30 60 100 Fuse Class (Performance) Class CF CUBEFuse (Class J) Class CF CUBEFuse (Class J) Class CF CUBEFuse (Class J) Single-Phase 480Vac 600Vac 712 10 20 25 30 40 Three-Phase 480Vac 600Vac 10 15 30 30 50 50 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Direct Current 250Vdc 5 10 15 Quik-Spec TM Electrical Gear A/C Disconnects -- Fused and Non-fused Series B22__ Specifications Description: Fused and non-fused rainproof air conditioner pullout units. Dimensions: See Catalog Numbers table. Construction: NEMA 3R rainproof metal housing with weather resistant coating. Wire Range: 14-3 AWG, Al/Cu Ratings: Phase: -- Single, 2-wire Volts: -- 240Vac Amps: -- 30-60A Agency Information: UL Listed to UL 1429, C-UL Certified, UL Guide WGEW Metallic Non-Fused Disconnect Metallic Fused Disconnect Metallic Non-Fused Disconnect with Weather ResistantTamper Resistant GFCI Receptacle. Quik-SpecTM Electrical Gear Features and Benefits * A/C disconnects meet NEC(R) Code Requirements under articles 440.14. GFCI units meet NEC(R) Code Requirements under articles 210.63, 210.8, and 406.8(B)(1). * NEMA 3R rainproof enclosures withstand outdoor environment. * Padlockable with two-position pullout handle to lock safety shield when in the ON position. (Not available on GF or NA units.) For added safety, pullout handle can be stored in the compartment in the off position. Typical Applications * Residential, light industrial/commercial A/C and heat pump service. * Spas/whirlpools, swimming pools, pump houses * Suitable for service entrance equipment applications with field installable ground bar, kit number DPFG. B222-60NF34W non-fused with cable whip Catalog Numbers Fused Catalog Numbers Description B221-30F 30A, Pullout B221-30FGF 30A, Pullout w/ GFCI B221-30FGFWRTR 30A, Pullout w/ WRTRRated GFCI B222-60F 60A, Pullout B222-60FGF 60A, Pullout w/ GFCI B222-60FGFWRTR 60A, Pullout w/ WRTRRated GFCI Disconnect Max Hp Rating Rating 120V 240V 30A 1.5 3 30A 1.5 3 30A 1.5 3 Wire Range 60 or 75C CU/AL #14-3 #14-3 #14-3 Enclosure Type NEMA 3R NEMA 3R NEMA 3R Fuse Class H or R H or R H or R Approx. Dimensions (in) Height Width Depth 8 34 5 38 2 78 13 7 12 4 34 13 7 12 4 34 60A 60A 60A 3 3 3 10 10 10 #14-3 #14-3 #14-3 NEMA 3R NEMA 3R NEMA 3R H or R H or R H or R 8 34 13 13 5 38 7 12 7 12 2 78 4 34 4 34 60A 60A 60A 3 3 3 10 10 10 #14-3 #14-3 #14-3 NEMA 3R NEMA 3R NEMA 3R * * * 8 34 11 34 11 34 5 38 6 12 6 12 2 78 4 12 4 12 60A * 10 #14-3 NEMA 3R * 8 34 5 38 3 58 60A* 60A** 3 3 10 10 #14-3 #14-3 NEMA 3R NEMA 3R * * 14 34 14 34 12 12 12 12 4 4 Non-Fused B222-60NF B222-60NFGF B222-60NFGFWRTR B222-60NFNA 60A, Pullout 60A, Pullout w/ GFCI 60A, Pullout w/ WRTRRated GFCI 60A, Switch Non-Fused Cable Whip B222-60NF12W B222-60NF34W 60A, Pullout w/ 12" Cable Whip 60A, Pullout w/ 34" Cable Whip Cable Whip Specifications Catalog Numbers Description B222-60NF12W 60A, Pullout w/ 12" Cable Whip B222-60NF34W 60A, Pullout w/ 34" Cable Whip Pullout Rating 60A 60A Max UpstreamWire Overcurrent Harness Ground Hot Protection Device Diameter Wire Size 1 30A 2" #10 3 50A 4" #8 Flexible Conduit Wire Size Length (ft) #10 6 #10 6 * Upstream overcurrent protection device (OCPD) not to exceed 30 Amps. **Upstream overcurrent protection device (OCPD) not to exceed 50 Amps. 30 and 60A pullout replacement handle: 96-3258-4. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Non-Metallic Fittings 1 - 90, 1 - Straight 1 - 90, 1 - Straight Data Sheet: 1143 247 248 Fuse Holders and Blocks Section Contents Page HHT Series in-line fuse holders for 5 X 15 to 20mm fuses . . . . . . . . . . . . . . . . . . . . . . . . .278 Tron(R) in-line fuse holders . . . . . . . . . . . . . . . . . . . . . 279-280 Panel mounted fuse holders for 5 X 20mm fuses . . . . . . .281 Panel mounted fuse holders for 14" X 1 14" fuses . . . . . . . . 282 Panel mounted fuse holders for 5 X 20mm and 1 4" X 1 14" fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283-284 Panel mounted fuse holders for indicating type fuses . . 285 Panel mounted fuse holders for 13 32" X 1 516" to 1 12" fuses . . . . . . . . . . . . . . . . . . . . . . . . .286 Panel mounted fuse holders for 13 32" X 1 12" fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .287 Fuse blocks for 14" X 1 14" fuses . . . . . . . . . . . . . . . . . . . . 288 Fuse blocks for 14" X 1" fuses . . . . . . . . . . . . . . . . . . . . . . 289 Fuse blocks for 1332" X 1 12" fuses . . . . . . . . . . . . . . . . . . . .290 Rail mount fuse holders . . . . . . . . . . . . . . . . . . . . . . . . . . 291 RED indicates NEW information 249 Fuse Holders & Blocks OPM-1038 3-pole fuse holders with disconnect switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 OPM-1038 3-pole fuse holders . . . . . . . . . . . . . . . . . . . .251 OPMNGA- 3-pole Class CC and 1332" X 1 12" fuse overcurrent protection modules . . . . . . . . . . .252-253 CH Series Class J modular fuse holders . . . . . . . . . . . . 254 JT(N)60030 & JT(N)600600 Safety JTM Class J fuse holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255-256 CH Series Global Modular fuse holders . . . . . . . . . 257-258 SAMITM fuse covers . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 H250 & R250 Series 250V Class H (K) and R fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . .260-262 H600 & R600 600V Class H (K) and R fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . .263-265 J600 Series Class J fuse blocks . . . . . . . . . . . . . . 266-267 JP Series Class J fuse blocks . . . . . . . . . . . . . . . . . . . . 268 JA60030 add-a-pole Class J fuse blocks . . . . . . . . . . . . 268 T300 300V Class T fuse blocks . . . . . . . . . . . . . . . 269-270 T600 600V Class T fuse blocks . . . . . . . . . . . . . . . 271-272 BCA Series Class CC add-a-pole modular fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273 BMA Series 1332" X 1 12" fuse add-a-pole modular fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273 BC Series Class CC fuse blocks . . . . . . . . . . . . . . . . . .274 BM Series Type M 1332" X 1 12"" fuse blocks . . . . . . . . . . .274 BG & G Series Class G fuse blocks . . . . . . . . . . . . . . . 274 BH Series high speed fuse modular fuse blocks . . . . . 275 Class H & J modular fuse blocks . . . . . . . . . . . . . . . . . .275 Plug fuse box cover units . . . . . . . . . . . . . . . . . . . . . . .276 HFB & HEB-10 in-line fuse holders for 14" X 1 14" fuses . . . . . . . . . . . . . . . . . . . . . . . 277, 279 HHB & HRK universal in-line fuse holders for 1 4" dia. fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277 HR & HM Series in-line fuse holders for 14" dia. fuses . . 278 HFA Series waterproof in-line fuse holders for 14" X 1 14" fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . .278 Fuse Holders and Blocks Optima(R) Fuse Holder Module and Disconnect Switch OPM-1038 With Disconnect Switch Typical Applications * Industrial Control * Process Control Systems * Automated Warehouse Systems Communication * Individual Control Circuits Catalog Number Build-A-Code Series O P M - Features/Benefits * Padlockable with finger-safe terminals for safety. Qualified as IP20 per IEC 60529. * Cam-action handle for easy module removal, offered with Class CC rejection clips or European 10 x 38mm clips to meet global needs * Wire ready with 35mm DIN rail or screw panel mounting (#8 screw, 114" long) saves installation time * Fuse indication lights with option for remote fuse status available. See Data Sheet for additional wiring details. Fuse Type 1 0 3 8 S W Blank = 10 x 38mm or 1332" x 1-12" R = Class CC Dimensions C= Communication Feature 5.72 ( .045) (145.3mm) ( 1.14) 4.25 ( 0.03) (108.0mm) ( 0.76) 0.43 ( 0.03) (10.9mm) ( 0.76) 1.38 (35.0mm) 3-Phase Volts HP 240 5 480 10 600 15 6T3 * * * * Midget (Non-Rejection) KTK FNM FNQ Communication Port 3L2 1.76 0.27 (6.9mm) (44.7mm) 5L3 0.74 (18.8mm) 0.31 (7.9mm) 0.57 ( 0.03) (14.5mm) ( 0.76) 3.74 ( 0.03) (95.0mm) ( 0.76) Communication Port 3.17 (80.5mm) 0.23 (5.8mm) 0.50 (12.7mm) 0.44 (11.2mm) 0.224 (5.6mm) Recommended Fuse Types Class CC LP-CC KTK-R FNQ-R 1L1 4T 2 BUSS Specifications Description: 3-pole load break modular fuse holder and disconnect switch for 1332 x 112" (10 x 38mm) fuses. Dimensions: See Dimensions illustration. Poles: 3 Agency Information: CE, UL (see table), CSA Certified, C22.2 No. 39, Class 6225-01, File 47235, IEC (see table). Flammability Rating: UL 94V0. Horsepower Rating of Switch 2T1 European C10M C10G 1.86 (47.2mm) Panel Mounting Hole Pattern 3.60 (91.4mm) 1.312 ( 0.01) (33.3mm) ( 0.25) Panel Mounting Hole Pattern Physical Characteristics Small size matches 45mm IEC starter width Accepts #8-18 AWG stranded, #10-18 AWG solid wire 3-pole Handle and shaft required for through the door operation Catalog Numbers Catalog Numbers OPM-1038SW Electrical Rating 30A, 600Vac UL/CSA OPM-1038RSW 32A, 660Vac IEC 30A, 600Vac UL/CSA OPM-1038SWC 30A, 600Vac UL/CSA OPM-1038RSWC 32A, 660Vac IEC 30A, 600Vac UL/CSA SCCR** Rating * 100kA * 100kA Clips Non-rejection, 10x38mm or 13 32" x 1 12" Rejection, Class CC Non-rejection, 10x38mm or 13 32" x 1 12" Rejection, Class CC Remote Open Fuse Indication No No Yes Yes UL Information Std. Recognized UL 508 Listed UL 508 Recognized UL 508 Listed UL 508 File Guiide IEC CE E161278 NLRV2 IEC 60947-3 Yes E161278 NLRV E161278 NLRV2 E161278 NLRV *Rating varies depending on fuse used in module; 100kA maximum **Short-Circuit Current Rating Data Sheet: 1103 250 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Yes IEC 60947-3 No No Fuse Holders and Blocks Optima(R) Fuse Holder Module OPM-1038 Features/Benefits * Padlockable with finger-safe terminals for safety. Qualified as IP20 per IEC 529. * Cam-action handle for easy module removal. * Offered with Class CC rejection clips or European 10 x 38mm clips to meet global needs * Wire ready with 35mm DIN rail or screw panel mounting (#8 screw, 1 14" long) saves installation time * Fuse indication lights with option for remote fuse status indication. See Data Sheet for additional wiring details. Catalog Number Build-A-Code Series Fuse Type O P M - 1 0 3 8 Blank = 10 x 38mm or 13 32" x 1 12" R = Class CC Typical Applications * Industrial Control Communication * Process Control Systems * Automated Warehouse Systems * Individual Control Circuits Dimensions C= Communication Feature 3.22 ( 0.03) (81.8mm) ( 0.76) 2T1 IL1 Midget (Non-Rejection) KTK FNM FNQ European C10M C10G Communication Port 3L2 0.27 (6.9mm) 5L3 0.74 (18.8mm) 0.31 (7.9mm) 3.60 ( 0.03) (91.4mm) ( 0.76) 0.57 (14.5mm) Fuse Holders & Blocks Class CC LP-CC KTK-R FNQ-R 4T2 1.76 ( 0.03) (44.7mm) ( 0.7 ) 6T3 BUSS Specifications Description: 3-pole modular fuse holder for 1332" x 1 12" (10 x 38mm) fuses. Dimensions: See Dimensions illustration. Poles: 3 Agency Information: CE, UL (see table), CSA Certified, C22.2 No. 4248, Class 6225-01, File 47235, IEC (see table). Flammability Rating: UL 94V0. Recommended Fuse Types 3.74 ( 0.03) (95.0mm) ( 0.76) 3.17 (80.5mm) Communication Port 1.65 ( 0.03) (41.9mm) ( 0.76) 0.23 (5.8mm) 0.50 (12.7mm) 0.44 (11.2mm) Physical Characteristics * Small size matches 45mm IEC starter width * Accepts #8-18 AWG stranded, #10-18 AWG solid wire * 3-pole 0.224" (5.6mm) 1.312 ( 0.01) (33.3mm) ( 0.25) Panel Mount Hole Pattern 3.60 ( 0.03) (91.4mm) ( 0.76) 1.86 ( 0.03) (47.2mm) ( 0.76) Panel Mount Hole Pattern Catalog Numbers Catalog Numbers OPM-1038 OPM-1038R OPM-1038C OPM-1038RC Electrical Rating 30A, 600Vac/dc UL/CSA (Max 3 Watts per fuse) 32A, 660V IEC 30A, 600Vac/dc UL/CSA 30A, 600Vac/dc UL/CSA (Max 3 Watts per fuse) 32A, 660V IEC 30A, 600Vac/dc UL/CSA SCCR** Rating * 200kA * 200kA Clips Non-rejection, 10 x 38mm or 13 32" x 1 12" Rejection, Class CC Non-rejection, 10 x 38mm or 13 32" x 1 12" Rejection, Class CC Remote Open Fuse Indication No UL Information Std. Recognized UL 4248 No Listed UL 4248 Recognized UL 4248 Yes Yes Listed UL 4248 File E14853 Guid de IZLT2 E14853 IZLT E14853 IZLT2 E14853 IZLT IEC IEC 60269-2-1 CE Yes Yes IEC 60269-2-1 No No *Rating varies depending on fuse used in module; 200kA maximum. **Short-Circuit Current Rating Data Sheet: 1102 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 251 Fuse Holders and Blocks Optima(R) Three-pole Overcurrent Protection Module Fuse Holder Wire Range: -- 75Cu Only -- #18-12 Single/Dual, torque 15lb-in -- #10-8 Single/Dual, torque 20lb-in -- Dual wire with same gauge and type OPM-NG- 75 Cu Only [mm2] AWu (N*m)/lb-in AWG [mm2] (N*m)/lb-in #18-8 x 1 1-6 x 1 18-12 Single/Dual #18-8 x 1 1-6 x 1 18-12 Single/Dual #18-8#18-8 x 2 x 21-6 1-6 x 2 x 2Strld 15lb-in (1.7#18-8 N*m) x 1 #18-8 x 1 1-6 x 1 10-8 Single/Dual #18-8#18-8 x 2 x 21-6 1-6 x 2 x 2 10-8 Single/Dual 1-4 1-4 x 1 x 1 20lb-in (2.5 N*m) 20in-lb (2.5 N*m) 1-4 1-4 x 2x 2 Solid Solid 1-6 x1 Stranded Ferrules Ferrules Specifications Description: OPM-NG-SC3: 3-pole Class CC fuse holder for use with Class CC fuses (Cooper Bussmann Types LP-CC, FNQ-R, KTK-R). OPM-NG-SM3: 3-pole fuse holder for use with 1332" x 112" and 10.3 x 38mm fuses (Cooper Bussmann Types: 1332" x 112"; KTK, FNQ, KLM, 10 x 38mm; FWA, FWC, C10G_ _, C10M_ _). Ratings: Volts: -- OPM-NG-SC3: 600Vac (or less) -- OPM-NG-SM3: 600Vac (or less) UL and CSA 30A -- OPM-NG-SM3: 690Vac (or less) IEC 32A Amps: -- OPM-NG-SC3: 0-30A -- OPM-NG-SM3: 0-30A SCCR:-- OPM-NG-SC3: 200kA -- OPM-NG-SM3: Same as fuse IR, 200kA maximum Agency Information: CE, UL; OPM-NG-SC3 UL Listed, UL 4248, File E14853, Guide IZLT. OPM-NG-SM3, UL Recognized, UL 4248, File E14853, Guide IZLT2. CSA Certified, C22.2 No. 4248, Class 6225-01, File 47235. IEC 60947-3 Utilization Category AC20B. Handling & Storage Temperature: -10 to 65C. Features/Benefits * 45mm width matches IEC starters * 35mm DIN rail or panel mounting feature. Maximum screw size #8 (M4) * Pressure plate terminations with dual-wire rated terminals (see Wire Table) and optional auxiliary contacts * Integrated collapsible handle and fuse carrier cannot be removed from holder base * Padlockable and IP20 finger-safe to IEC60529 Typical Applications * Mass Produced Control Systems * Process Control Systems * Automated Warehouse Systems * Individual Control Circuits Input Power Terminal Wire Range: Wiring Tightening Torque: Solid Conductor Stranded Conductor Connector Screw Clamp (1) #14 to #2 (1.5 (2) #14 to #6 (1.5 (1) #14 to #2 (1.5 (2) #12 to #6 (2.5 20lb-in (2.2 N*m) 15lb-in (1.7 N*m) 25mm2) 10mm2) 25mm2) 10mm2) or conductor conductors conductor or conductors Materials: -- Housing: Thermoplastic - ULV2 -- Clip: Tin-plated copper alloy -- Contact lubricant: Fluoroether grease -- Saddle screw: Plated steel -- DIN rail springs: Stainless steel Optional Accessories: Comb Bar (Max current rating = 63A) OPMNGSA245 OPMNGSA254 OPMNGSA272 OPMNGSA345 OPMNGSA354 OPMNGSA445 OPMNGSA454 OPMNGSA472 OPMNGSA554 2 2 2 3 3 4 4 4 5 circuit, circuit, circuit, circuit, circuit, circuit, circuit, circuit, circuit, 45mm 54mm 72mm 45mm 54mm 45mm 54mm 72mm 54mm between between between between between between between between between same same same same same same same same same phases phases phases phases phases phases phases phases phases Input Terminal Block (Max current rating = 63A) OPMNGSA005 Input/Feed Through Power Terminal, Supports feed through to another system, DIN rail mount only OPMNGSA009 Input Power Terminal Cover OPMNGSA010 Protective Cover for unused terminals on comb bar Auxiliary Contacts OPMNGSAAUX11 OPMNGSAAUX20 NO/NC NO/NO Marking Tabs OPMNGSA101 Marking Tab - Mounts to front of carrier, quantity 100 Data Sheet: 1109 252 to to to to For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Holders and Blocks Optima(R) Three-pole Overcurrent Protection Module Optional Accessories Dimensions Millimeters ( 0.38), Inches ( .015) Fuse Holders & Blocks Data Sheet: 1109 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 253 Fuse Holders and Blocks Class J Modular Fuse Holders CH _ _ J _ Specifications Description: IP20 finger-safe, 1- to 3-pole Class J fuse holder with DIN rail or panel mounting. Ratings: Volts: -- 600Vac/dc (or less) Amps: -- 30A (30A version) -- 60A (60A version) Withstand Rating SCCR: -- 200kA Wire Range: Cu solid and stranded conductors with single (1-18AWG) and dual (3-18AWG) wire ratings. See Catalog Numbers table for details. Torque Rating:10-18AWG 24 lb-in. 1-8AWG 35 lb-in. Poles: 1-, 2- or 3-Pole. Storage & Operating Temperature Range*: -20C to 75C. Agency Information: CE, UL 4248/CSA 22.2 No. 4248. Flammability Rating: UL 94V0. 30 Amp Version 60 Amp Version Catalog Numbers See Catalog Numbers table below. Dimensions (mm): Features and Benefits * Choice of local fuse indication; easyIDTM viewing window (for seeing indicator on LPJ-SPI indicating fuse) or neon lamp. * Versatile 1-, 2- and 3-pole versions for 0-30A and 35-60A fuses with dual wire rated connections simplify wiring. * Improved electrical safety with IP20 finger-safe construction with lock-out/tag-out feature. 3-phase fuse extraction assures all phases are opened for service work. * Flexible panel/35mm DIN rail mounting mounting options Fuse Size 0-30A 35-60A Poles W D H 1 2 3 1 2 3 32 64 96 40 80 120 70 70 70 83 83 83 115 115 115 125 125 125 *For fuse selection on applications above or below 25C, consult derating charts in Cooper Bussmann publication "Selecting Protective Devices" (SPD). Catalog Numbers Catalog Amp Volts # of Numbers Rating (AC/DC) Poles IP20 Finger-Safe Mounting Padlockable Local Indication AWG Single Wire Range CH30J1 CH30J1I CH30J2 CH30J2I CH30J3 CH30J3I 30 30 30 30 30 30 600 600 600 600 600 600 1 1 2 2 3 3 Yes Yes Yes Yes Yes Yes 35mm 35mm 35mm 35mm 35mm 35mm DIN/ DIN/ DIN/ DIN/ DIN/ DIN/ Panel Panel Panel Panel Panel Panel Yes Yes Yes Yes Yes Yes easyID** Neon Lamp*** easyID** Neon Lamp*** easyID** Neon Lamp** 1-18 1-18 1-18 1-18 1-18 1-18 CH60J1 CH60J1I CH60J2 CH60J2I CH60J3 CH60J3I 60 60 60 60 60 60 600 600 600 600 600 600 1 1 2 2 3 3 Yes Yes Yes Yes Yes Yes 35mm 35mm 35mm 35mm 35mm 35mm DIN/ DIN/ DIN/ DIN/ DIN/ DIN/ Panel Panel Panel Panel Panel Panel Yes Yes Yes Yes Yes Yes easyID** Neon Lamp*** easyID** Neon Lamp*** easyID** Neon Lamp*** 1-18 1-18 1-18 1-18 1-18 1-18 ** easyIDTM viewing window, requires use of Cooper Bussmann LPJ_SPI permanent indication fuses. *** Indication non-fuse dependent, minimum voltage 90Vac/115Vdc. Data Sheet: 2144 254 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Holders and Blocks Class J (Finger-safe) Fuse Holders Safety JTM -- JT(N)60030 & JT(N)60060 30 Amp Version 60 Amp Version Fuse Holders & Blocks Specifications Description: Indicating and non-indicating finger-safe, DIN rail mount fuse holders for use with Class J fuses - (Cooper Bussmann(R) LPJ, JKS). Dimensions: See Dimensions illustrations. Ratings: Volts: -- 600Vac Amps: -- 0-60A (JT(N)60060) -- 0-30A (JT(N)60030) SCCR:-- 200,000A RMS Sym. -- 300,000A self certified using Cooper Bussmann LPJ_SP fuses Agency Information: CE, Listed to UL 4248: Guide IZLT, File 14853, CSA Certified: Class 6225-01, File 47235. IP20 per IEC 60529. Flammability Rating: UL 94V0. Indication: Min voltage: 90Vac, 115Vdc; neon lamp "ON" when fuse opens, voltage source and current path are present. Terminations: 30A dual port torque 20lb-in, 60A single port torque 45lb-in, terminal construction, tin-plated copper alloy. Wire Size: JT(N)60030 - rated for 75C, AWG#18-#8; Cu only, JT(N)60060 - rated for 75C, AWG#14-#4; Cu only. (Note: For JT(N)60030 use both stranded or solid, in a variety of dual wire combinations of same wire size and type.) Features and Benefits * Short-Circuit Current Rating of 300,000A with Cooper Bussmann LPJ___SP fuses. * Rapid, flexible 35 mm DIN rail mounting. * One piece interlocking design for assembling multiple pole blocks reduces inventory costs. * Removable fuse carrier allows fuse replacement away from base while maintaining finger-safe rating. Typical Applications * Industrial Controls * Process Controls * Small HP VFDs Catalog Numbers Catalog Numbers JT60030 JT60060 JTN60030 JTN60060 Amps 30 60 30 60 Indication Non-indicating Non-indicating Indicating (Neon) Indicating (Neon) Data Sheet: 1152 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 255 Fuse Holders and Blocks Class J (Finger-safe) Fuse Holders Dimensions for JT60030 & JTN60030 -- in (mm) 1.14 (29.0) 1.05 (26.7) Slot Din-rail .07 (1.8) MOUNTING 2.75 (69.9) Shown without fuse pullout cover 1 pole BUSS BUSS BUSS JT60030 0 - 30A 600VAC JT60030 0 - 30A 600VAC JT60030 0 - 30A 600VAC USE CLASS J FUSES USE CLASS J FUSES USE CLASS J FUSES DO NOT REMOVE UNDER LOAD DO NOT REMOVE UNDER LOAD DO NOT REMOVE UNDER LOAD 1.23 (31.2) 2.42 (61.3) 2 pole 3.60 (91.4) 3 pole 2.52 (64.1) Dimensions for JT60060 & JTN60060 -- in (mm) 1.31 (33.3) 1.25 (31.8) Slot Din-rail .10 (2.6) 3.10 (78.7) 1 pole BUSS BUSS BUSS JT60060 35 - 60A 600VAC JT60060 35 - 60A 600VAC JT60060 35 - 60A 600VAC USE CLASS J FUSES USE CLASS J FUSES USE CLASS J FUSES DO NOT REMOVE UNDER LOAD DO NOT REMOVE UNDER LOAD DO NOT REMOVE UNDER LOAD 1.52 (38.1) 2 pole 3 pole MOUNTING 2.96 (75.2) 4.40 (111.7) Shown without fuse pullout cover 3.06 (77.7) JT(N)600 Series fuse blocks can be dovetailed together within the same current rating to provide multiple pole block configurations. NOTE: JT(N)60030 cannot be dovetailed to JT(N)60060. Data Sheet: 1152 256 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Holders and Blocks Global Modular Fuse Holders CH Series - 8x32, 10x38, 14x51, 22x58, Class CC Specifications Description: The `CH' line of modular fuse holders accommodates many fuses from around the world, including North American Class-CC, Midget, Class gR, aR HSF, and IEC Industrial Ferrule (Class gG and aM) in four physical sizes: 8x32, 10x38, 14x51 and 22x58mm. Agency Information: Manufactured in accordance with IEC 60269 and IEC 60947-3. Agency Compliance as indicated in the Catalog Numbers table. Features/Benefits * Optional open fuse indication (minimum 90Vac, 115Vdc for indicator lights) * 14x51 & 22x58mm configurations available with optional micro-switches for remote open fuse indication, pre-breaking, and fuse presence * Multi-phase connections available for ganging poles * Low voltage indicating device available for CC and midget (48V) Modular Fuse Holder Selection Table (10 x 38 and CC) Part Numbers Series Size CHCC Class CC UL 600Vac/dc 30A UL CHCC1DI-48*** 48Vdc, 30A -- CHM 10X38 & Midget CHPV1 CHPV1I** CHM1D CHM1DNX CHM1DN CHM2D CHM3D CHM3DN CHM4D CHM1DI** CHM1DNI** CHM2DI** CHM3DI** CHM3DNI** CHM4DI** UL 600Vac/dc, 30A IEC 690Vac, 32A (3 Watt) __ CHM1DI-48*** UL 48Vdc, 30A IEC 48Vdc, 32A (3 Watt) 1000Vdc 30A UL IEC Phase Configuration 1-pole 2-pole 3-pole No. of 17.5mm Modules* 1 2 3 Box Qty. 12 6 4 1-pole 1 12 Terminal Rating SCCR Rating 75 Cu Wire Only 200kA * * * * * * * * 1-pole 1 12 75 Cu Wire Only 33kA 1-pole 1 Neutral Pole 1-pole + Neutral 2-pole 3-pole 3-pole + Neutral 4-pole 1 1 2 2 3 4 4 12 12 6 6 4 3 3 75 Cu Wire Only Rating varies depending on fuse used in holder. * 1-pole 1 12 Cooper Bussmann Fuses LP-CC, FNQ-R, KTK-R PV Series Fuse Holders & Blocks CHPV Max Voltage & Current Catalog Numbers W/O Indication W/Indication CHCC1D CHCC1DI** CHCC2D CHCC2DI** CHCC3D CHCC3DI** FNQ, KLM, FNM, KTK, BAF, FWA, DCM, C10 Series, AGU, FWC UL Recognized (cURus) UL LIsted (cULus) Self Certified *Holder width as compared to standard 17.5mm module, i.e., 1 = 17.5mm 2 = 35mm. **90V miminum required for illumination ***12V mininum required for illumination MFH Wire Range and Torque CH Series: CHCC, CHM & CHPV Wire Range 18-12 AWG (0.8 - 4mm2) 10 AWG (5.0mm2) 10-8 AWG (5.0 - 8.0mm2) 18-14 AWG (0.8 - 2.0mm2) 18-10 AWG (0.8 - 5.0mm2) Conductor Type 75C Cu Wire Only Conductors Torque Solid/Stranded Single 20 lb-in 2.3 N* m Solid Single Stranded 25 lb-in (2.8 N* m) Solid Dual Stranded For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 257 Fuse Holders and Blocks Global Modular Fuse Holders Modular Fuseholder Selection Table (8x32, 14x51, and 22x58) Part Numbers Series/ Size CH08 8X32 CH14 14X51 CH22 22X58 Max Catalog Numbers Voltage W/O Indication W/Indication & Current CH081D CH081DI CH081DNX 400Vac CH081DNS CH081DNSI 25A CH081DN CH081DNI IEC CH082D CH082DI 400Vac CH083D CH083DI 25A CH083DNS CH083DNSI CH083DN CH083DNI CH084D CH084DI UL/CSA CH141DICH1 40A CH141D CH141DMS -14X51 (5 Watt) UL/cURus CH141DNX IEC 600Vac/dc, CH141DN CH141DNI 690Vac, CH142D CH142DI 50A40A (5 Watt) CH143D CH143DI IEC CH143DMS 690Vac, CH143DN CH143DNI UL 50A CH143DNMS 600Vac/dc, CH144D CH144DI 100A CH221B NotCH22 (9.5 Watt) Not CH221BMS Available22X58IEC UL/cURus Available CH221BNX with 690Vac, 600Vac/dc, with CH221BN local 125A 100A local CH222B neon (9.5 Watt) neon CH223B indicatio IEC indication CH223BMS (remote 690Vac, (remote CH223BN microswitch 125A microswitch CH223BNMS only) only) CH224B IEC * * * * * * * * * * * * * * * * * * * * * * * * * * * * * UL Phase Configuration 1-pole 1 Neutral Pole 1-pole + Neutral 1-pole + Neutral 2-pole 3-pole 3-pole + Neutral 3-pole + Neutral 4-pole 1-pole 1-pole + Microswitch 1 Neutral Pole 1-pole + Neutral 2-pole 3-pole 3-pole + Microswitch 3-pole + Neutral 3-pole + Neutral + Microswitch 4-pole 1-pole 1-pole + Microswitch 1 Neutral Pole 1-pole + Neutral 2-pole 3-pole 3-pole + Microswitch 3-pole + Neutral 3-pole + Neutral + Microswitch 4-pole UL Recognized (cURus) UL LIsted (cULus) *Holder width as compared to standard, i.e., 1 = 17.5mm module 2 = 35mm. **90V miminum required for illumination No. of 17.5mm Modules* 1 1 1 2 2 3 3 4 4 1.5 1.5 1.5 3 3 4.5 4.5 6 6 6 2 2 2 4 4 6 6 8 8 8 Box Qty. 12 12 12 6 6 4 4 3 3 6 6 6 3 3 2 2 1 1 1 6 6 6 3 3 2 2 1 1 1 Wire Range Maximum Torque 1-16mm2 (18-6 AWG) 2.5 N* m (22in-lb) 1-10mm2 (18-8 AWG) 1-16mm2 (18-8 AWG) 2.0 N* m (17.5in-lb) 2.5 N* m (22in-lb) 1-16mm2 (18-6 AWG) 2.5 N* m (22in-lb) 2.5-16mm2 (14-6 AWG) 3.0 N* m (26in-lb) 2.5-50mm2 (14-1 AWG) 4.0 N* m (35in-lb) Accessories for CH Series Catalog Numbers AL-D JV-L CH810-HP CH14-HP C08NL C14NL C22NL CH14MS-1D CH14MS-3D CH-PLC**** CH22LS CH22IP20 For Use with Fuse Holders CH08 and Multi-Phase Connection Links CH14 Series CHM and Multi-Phase Connection Kit*** CHCC Series CH08 Series Multi-Phase Handle Pins CH14 Series CH08 Series CH14 Series Neutral Links CH22 Series CH141 Series Operated-Fuse Micro-Switches CH143 Series CHM and PLC Module CHCC Series 22x58 Lock Support CH22 Series 22x58 IP20 Protection CH22 Series Accessory Accessory No. of Poles - 12 - - - - - - - 1 3 10 1 1 Multi-Phase Connection Links 258 Neutral Links Multi-Phase Handle Pins For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 10 5 2 - 5 - 12 ***Kit contains 3-Spring pins and 6-connection links ****OL Listed (cULus) Operated-Fuse Micro-Switches Carton Qty. Programmable Logic Controller (PLC) Fuse Holders and Blocks SAMITM Fuse Covers SAMI-1I SAMITM Series SAMI-2I SAMI-3I SAMI-6I SAMI-7I Dimensions TEST PROBE A B 1.03 C 1.94 1.30 1.30 1.30 1.30 1.17 0.75 1.50 0.75 2.07 2.33 2.18 2.18 2.14 1.72 2.33 1.72 LINE TEST PROBE Buss SAMI -2 SAMI-2_ SAMI-3_ SAMI-4_ SAMI-5_ SAMI-6_ SAMI-7_ SAMI-8_ SAMI-9_ Dimensions (inches) Description A 600V, J (0-30A) and 600V, T (35-60A)** 5.02 250V, RK, K5, H (35-60A) 600V, RK, K5, H (0-30A) 7.03 600V, J (65-100A) 7.03 250V, RK, K5, H (65-100A) 8.20 600V, RK, K5, H (35-60A) 8.20 600V, J (35-60A) 4.98 600V, Midget, Class CC, G (0-30A) 3.82 600V, RK, K5, H (65-100A) 10.38 250V, RK, K5, H (0-30A) and 600V, 3.82 T (0-30A) Fuse Holders & Blocks Typical Applications * Class H, R and J fuse blocks up to 100A * Class T fuse blocks up to 60A * Class CC, G and Midget, 30A fuse blocks Catalog Numbers Catalog Numbers* SAMI-1_ SAMI-8I Features and Benefits * Insulated cover allows field conversion of fuses mounted in open fuse blocks to dead front configuration. * Optional open fuse indicating light aids in system troubleshooting. * Units are re-usable. * Allows visual marking of line and load side of fuses. LOAD Specifications Description: Indicating and non-indicating fuse covers for Class J, RK1, RK5, H, K5, CC, G (0-30A) and midget-type fuses. Indicating feature requires a minimum of 90Vac or 115Vdc to illuminate lamp. One cover required for each pole. WARNING: To avoid electrical shock, turn power off before installing, removing or servicing. Dimensions: See Dimensions illustration. Ratings: Volts: -- Non-Indicating - 0-600Vac/dc -- Indicating - 90 to 600Vac -115 to 600Vdc Amps: -- 0-100A Agency Information: CE, UL Listed; SAMI-1I through SAMI-6I, SAMI-8I and SAMI-9I, SAMI-1N through SAMI-6N, SAMI-8N and SAMI-9N, UL Recognized; SAMI-7I and SAMI-7N, CSA Certified, File LR47235-93C. SAMI-4I B C FUSE *For indicating cover, add suffix "I", for non-indicating cover, add suffix "N". Example: SAMI-7I = Indicating, SAMI-7N = Non-indicating. **Available in non-indicating only. SAMI-8A adapter available for small Fusetron(R) body design. SAMI-8I and SAMI-8N come standard with adapter (SAMI-8A). Not for use with KTS-R fuses. Data Sheet: 1204 (Trimming Guides: 12041, 12042, 12043, 12044, 12045, 12046, 12048, 12049) For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 259 Fuse Holders and Blocks Class H(K) and R Fuse Blocks - 250V H250 & R250 Series Specifications Agency Information: CE, UL Listed UL 4248, Guide IZLT, File E14853; CSA Certified, Class 6225-01, File 47235. Flammability Rating: UL 94V0. Descriptions: H250 Series: 1-, 2- and 3-pole fuse blocks for use with Class H fuses. R250 Series: 1-, 2- and 3-pole fuse blocks for use with Class R fuses (Cooper Bussmann LPN-RK and FRN-R, DLN-R and KTN-R fuses). Dimensions: See Dimensions illustrations. Ratings: Volts: -- 250Vac/dc (H250 & R250 Series) Amps: -- 110-600A SCCR: -- H250 Series; 10kA RMS Sym. -- R250 Series; 200kA RMS Sym. Features and Benefits * H250 fuse blocks provide one, two and three pole housing for Class H, K and R fuses at 250Vac. * H250 fuse blocks are listed with a Short-Circuit Current Rating of 10kA RMS Sym. * R250 fuse blocks provide one, two and three pole housing for Class R fuses at 250Vac. * R250 fuse blocks are listed with a Short-Circuit Current Rating of 200kA RMS Sym. Typical Applications * 250Vac/dc or less Control Systems * 250Vac/dc or less Industrial Control * 250Vac/dc or less Industrial Control Circuits Recommended DIN rail adapters for the 110-30A series * see page 413. Class H Fuseblocks (250V) Catalog Data (for NON and REN Fuses) Terminal Type (Suffix No.) Screw Box Lug w/ Pressure Plate & Clip with Reinforced Spring Poles Catalog Number -- Clip with Reinforced Spring 1 10 to 30 1 2 3 H25030-1 H25030-2 H25030-3 S S S SR SR SR P P P PR PR PR C C C CR CR CR -- -- -- Q -- -- 1 2 3 31 to 60 61 to 100 101 1 2 3 1 2 3 H25060-1 H25060-2 H25060-3 H25100-1 H25100-2 H25100-3 -- -- -- -- -- -- -- -- -- SR SR SR -- -- -- -- -- -- -- -- -- -- -- -- C C C -- -- -- CR CR CR CR CR CR CO CO CO -- -- -- -- -- -- -- -- -- 4 5 6 7 8 9 1 3 H25200-1 -- -- -- -- -- CR -- -- 10 H25200-3 -- -- -- -- -- CR -- -- 11 1 H25400-1 -- -- -- -- -- CR* -- -- 12 3 H25400-3 -- -- -- -- -- CR -- -- 13 -- -- -- -- -- CR -- -- 14 -- -- -- -- -- CR -- -- 15 Amps to 200 201 to 400 401 1 H25600-1 to 3 H25600-3 600 *UL Recognized, No CSA Certification. No UL, No CSA Certification. Pressure Plate -- Clip with Reinforced Spring Copper Only 0.25 Quick Connect Figure Number Data Sheet: H250 Series, 1112; R250 Series, 1110 260 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Wire Range C, CR #2-14 Cu, #2-12 Al P, PR #10-18 Cu Only Q N/A S, SR #10-18 Cu Only C, CR #2-14 Cu, #2-8 Al CO #2-14 Cu Only CR #1/0-8 Cu/Al SR #8W/ Ring Terminal CR 250kcmil-6 Cu/Al CR 500kcmil-4 Cu/Al CR (2) 500kcmil-4/0 Cu/Al Fuse Holders and Blocks Class H(K) and R Fuse Blocks - 250V Class R Fuseblocks (250V) Catalog Data (for LPN-RK, FRN-R, DLN-R and KTN-R Fuses) 31 to 60 61 to 100 101 to 1 2 3 Catalog Number R25030-1 R25030-2 R25030-3 1 2 3 1 2 3 R25060-1 R25060-2 R25060-3 R25100-1 R25100-2 R25100-3 -- -- -- -- -- -- -- -- -- -- -- -- CR CR CR CR CR CR -- -- -- -- -- -- -- -- -- -- -- -- 4 5 6 7 8 9 1 R25200-1 -- -- CR -- -- 10 -- CR -- -- 11 -- -- CR CR -- -- -- -- 12 13 CR 500kcmil-4/0 Cu/Al -- -- CR CR -- -- -- -- 14 15 CR 500kcmil-4/0 Cu/Al Poles Amps 1 10 to 30 Terminal Type (Suffix No.) Screw w/ Box Lug w/ 0.25" Pres. Clip Quick-- Plate -- Cu Only Connect SR PR CR COR QR* SR PR CR COR -- SR PR CR COR -- 3 R25200-3 -- 200 201 1 R25400-1 -- to 3 R25400-3 -- 400 401 1 R25600-1 -- to 3 R25600-3 -- 600 *UL Recognized, No CSA Certification. No UL, No CSA Certification. UL Recognized, CSA Certification Fig. No. 1 2 3 Wire Range COR #6-14 Cu Only CR #2-14 Cu, #2-12 Al PR #10-18 Cu Only QR N/A SR #10-18 Cu Only CR #2-14 Cu, #2-8 Al CR 1/0-8 Cu/Al CR 250kcmil-6 Cu/Al Dimensions - in 250V 110 to 30A 2.05" 1.25" 0.95" 1.09" 0.17" 0.75" 0.41" 0.25" 3" 2.5" 2 SPACES AT 0.95" - 1.91" Fuse Holders & Blocks 1.41" 0.22" 1.27" 3.03" 0.5" 1.52" 0.55" 0.22" DIAMETER FIGURE 1. 0.55" FIGURE 2. FIGURE 3. 250V, 31A to 60A 1.73 0.27 1.5 2.81 1.31 0.5 0.5 0.5 1.31 4.125 1.31 0.5 0.5 0.22 x 0.41 0.22 x 0.41 0.22 x 0.41 4.25 G 1.25 1.5 FIGURE 4. FIGURE 5. FIGURE 6. Data Sheet: H250 Series, 1112; R250 Series, 1110 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 261 Fuse Holders and Blocks Class H(K) and R Fuse Blocks - 250V 250V, 61A to 100A 1.81" 2.06" 0.25" 0.62" 0.59" 3.38" 1.56" 4.94" 1.56" 1.56" 0.59" 0.62" 0.62" 0.28" DIA. x 0.5" C'BORE 7.36" 2.38" 3.125" 2.125" FIGURE 7. 250V, 101A to 200A FIGURE 8. FIGURE 9. 250V, 101A to 200A 8" 5" 3.15 0.75 0.31 0.5 3.4" 3.0 2.0 6" 3" 0.5" 1" 2" 7.13" 0.34" DIA. HOLE THROUGH 0.34 DIAMETER 7.125 0.75" C'BORE 4.5" EYELETS TO ACCEPT 0.25" DIA. SCREW 3.0 3" 2.06" 2.06 9" FIGURE 10. FIGURE 11. 250V, 201A to 400A 4.0 1.0 0.31 0.63 250V, 201A to 400A 10.88 9.25 4.0 0.82 1.0 3.0 1.75 0.34 DIAMETER 9.06 4.0 9.06 0.75" C'BORE 0.34" DIA. HOLE THROUGH 3.0 2.5 3.02 FIGURE 13. FIGURE 12. 250V, 401A to 600A 4.97 1.0 0.31 1.125 250V, 401A to 600A 4.0 1.75 0.34 DIAMETER 1.87 11.0 5.0 11.0 0.75" C'BORE 14.74 11.0 4.97 1.0 0.34" DIA. HOLE THROUGH 3.0 3.0 4.0 FIGURE 15. FIGURE 14. Data Sheet: H250 Series, 1112; R250 Series, 1110 262 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Holders and Blocks Class H(K) and R Fuse Blocks - 600V H600 & R600 Series Specifications Descriptions: H600 Series: fuse blocks for use with 1-, 2- and 3-pole Class H fuses. R600 Series: fuse blocks for use with 1-, 2- and 3-pole Class R fuses (Cooper Bussmann LPS-RK, FRS-R, DLS-R and KTS-R fuses). Dimensions: See Dimensions illustrations. Ratings: Volts: -- 600Vac/dc (H600 & R600 Series) Amps: -- 110-600A SCCR: -- H600 Series; 10kA RMS Sym. -- R600 Series; 200kA RMS Sym. Agency Information: CE, UL Listed UL 4248, Guide IZLT, File E14853; CSA Certified, Class 6225-01, File 47235. Flammability Rating: UL 94V0. H60030-3C H60030-2PR Features and Benefits * H600 fuse blocks provide one-, two- and three-pole housing for Class H, K and R fuses at 600Vac. * H600 fuse blocks are listed with a Short-Circuit Current Rating of 10kA RMS Sym. * R600 fuse blocks provide one, two and three pole housing for Class R fuses at 600Vac. * R600 fuse blocks are listed with a Short-Circuit Current Rating of 200kA RMS Sym. Typical Applications * 600Vac/dc or less Control Systems * 600Vac/dc or less Industrial Control * 600Vac/dc or less Individual Control Circuits Fuse Holders & Blocks Class H Fuseblocks (600V) Catalog Data (for NOS and RES Fuses) Terminal Type (Suffix No.) Screw Amps Poles Catalog Number 10 1 H60030-1 to 2 H60030-2 30 3 H60030-3 31 1 H60060-1 to 2 H60060-2 60 3 H60060-3 61 1 H60100-1 to 2 H60100-2 100 3 H60100-3 101 H60200-1 1 to 3 H60200-3 200 201 1 H60400-1 to 3 H60400-3 400 401 1 H60600-1 to 3 H60600-3 600 No UL, No CSA Certification. UL Recognized, CSA Certification 1 -- Clip with Reinforced Spring Pressure Plate S S S -- -- -- -- -- -- SR SR SR -- -- -- -- -- -- P P P -- -- -- -- -- -- -- -- -- -- -- Box Lug w/ Pressure Plate & Clip with Reinforced Spring -- Clip with Reinforced Spring Figure Number PR PR PR -- -- -- -- -- -- C C C C C C -- -- -- CR CR CR CR CR CR CR CR CR 1 2 3 4 5 6 7 8 9 -- -- -- CR 10 -- -- -- CR 11 -- -- -- -- CR 12 -- -- -- -- -- CR 13 -- -- -- -- -- CR 14 -- -- -- -- -- CR 15 Wire Range C, CR #2-14 Cu, #2-12 Al P, PR, S, SR #10-18 Cu Only C, CR #2-14 Cu, #2-8 Al CR #1/0-8 Cu/Al CR 250kcmil-6 Cu/Al CR 500kcmil-4 Cu/Al CR (2) 500kcmil-4/0 Cu/Al Data Sheet: H600 Series, 1113; R600 Series, 1111 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 263 Fuse Holders and Blocks Class H(K) and R Fuse Blocks - 600V Amps Poles Class R Fuseblocks (600V) Catalog Data (for LPS-RK, FRS-R, DLS-R and KTS-R Fuses) 10 to 30 31 to 60 1 2 3 1 2 3 1 Catalog Number R60030-1 R60030-2 R60030-3 R60060-1 R60060-2 R60060-3 Terminal Type (Suffix No.) Screw w/ Box Lug w/ Pres. Clip -- Plate -- Cu Only SR PR CR -- SR PR CR COR SR PR CR COR -- -- CR -- -- -- CR -- -- -- CR -- 61 1 R60100-1 -- to 2 R60100-2 -- 100 3 R60100-3 -- 101 1 R60200-1 -- to 3 R60200-3 -- 200 201 1 R60400-1 -- to 3 R60400-3 -- 400 401 1 R60600-1 -- to 3 R60600-3 -- 600 No UL, No CSA Certification. UL Recognized, CSA Certification Fig. No. 1 2 3 4 5 6 Wire Range COR #6-14 Cu Only CR #2-14 Cu, #2-12 Al PR, SR #10-18 Cu Only CR #2-14 Cu, #2-8 Al -- -- -- CR CR CR -- -- -- 7 8 9 CR, 1/0-8 Cu/Al -- -- CR CR -- 10 11 CR 250kcmil-6 Cu/Al -- -- CR CR -- -- 12 13 -- -- CR CR -- -- 14 15 CR 500kcmil-4 Cu/Al CR (2) 500kcmil-4/0 Cu/Al Dimensionals - in 600V, 110 to 30A 1.73 0.26 1.54 2.90 1.56 0.25 0.62 0.25 1.56 4.25 1.56 0.62 0.62 0.28 x 0.5 0.28 x 0.5 0.28 x 0.5 6.25 3.13 1.56 FIGURE 1. FIGURE 2. 600V, 31 to 60A 2.06" 0.25" 1.81" 0.59" 3.38" 1.56" 0.62" 0.62" FIGURE 3. 0.59" 4.94" 1.56" 1.56" 0.62" 0.28" DIA. x 0.5" C'BORE 7.36" 2.38" 3.125" 2.125" FIGURE 4. FIGURE 5. FIGURE 6. Data Sheet: H600 Series, 1113; R600 Series, 1111 264 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Holders and Blocks Class H(K) and R Fuse Blocks - 600V 600V, 61 to 100A 2.22 2.38 0.34 0.88 0.67 4.03 1.81 0.88 5.84 1.81 1.81 0.67 0.88 0.28 x 0.5 0.28 x 0.5 0.28 x 0.5 9.5 4.25 2.63 FIGURE 7. FIGURE 8. FIGURE 9. 600V, 101 to 200A 3.15 0.75 0.31 9.0" 8.0" 6.5" 3.0 2.0 0.5 0.34 DIAMETER 3.15" 0.75" 0.34 DIAMETER 0.75" C'BORE 3.0 9.63 9.58" 0.75" DIA. C'BORE 0.50" Deep 5.5" 3.0" 3.31 2.04" Fuse Holders & Blocks FIGURE 11. FIGURE 10. 600V, 201 to 400A 4.02 1.0 0.56 0.63 11.63" 9.25" 3.0 1.75 0.34 DIAMETER 12.0 0.75" C'BORE 4.02" 1.00" 1.19" 3.0 0.34 DIAMETER 0.75" DIA. C'BORE 0.67" Deep 12.00" 7.00" 4.5 2.5" FIGURE 12. FIGURE 13. 600V, 401 to 600A 4.987 1.0 0.56 1.125 4.0 1.75 2.13" 0.34 DIAMETER 14.0 0.75" C'BORE 15.26" 11.0" 4.987" 1.00" 0.34 DIAMETER 0.75" DIA. C'BORE 0.67" Deep 14.00" 8.00" 3.0 5.5 3.00" FIGURE 15. FIGURE 14. Data Sheet: H600 Series, 1113; R600 Series, 1111 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 265 Fuse Holders and Blocks Class J Fuse Blocks J600 Series Specifications Description: 1-, 2- or 3-pole fuse blocks for use with Class J fuses (Cooper Bussmann(R) LPJ, DFJ and JKS). Dimensions: See Dimensions illustrations. Construction: Thermoplastic. Poles: 1 to 3 Ratings: Volts: -- 600Vac/dc Amps: -- 12-600A SCCR: -- 200kA RMS Sym. Agency Information: CE, UL Listed, UL 4248, Guide IZLT, File E14853, CSA Certified, C22.2 No. 4248, Class 6225-01, File 47235. Flammability Rating: UL 94V0. Mounting: Accepts DIN rail adapter DRA-1. Catalog Numbers Screw J60030-1S* J60030-2S* J60030-3S* -- -- -- -- -- -- -- -- -- -- -- Pressure Plate J60030-1P J60030-2P J60030-3P -- -- -- -- -- -- -- -- -- -- -- Box Lug J60030-1C J60030-2C J60030-3C J60060-1C J60060-2C J60060-3C -- -- -- -- -- -- -- -- Catalog Numbers Box Lug w/ Retaining Clip Amps J60030-1CR 1 1 2-30 J60030-2CR 2-30 J60030-3CR J60060-1CR J60060-2CR J60060-3CR J60100-1CR J60100-3CR J60200-1CR J60200-3CR J60400-1CR** J60400-3CR** J60600-1CR J60600-3CR* 31-60 31-60 61-100 61-100 101-200 101-200 201-400 201-400 401-600 401-600 Features and Benefits * J600 fuse blocks provide one-, two- and three-pole housing for Class J fuses at 600Vac. * J600 fuse blocks are listed with a Short-Circuit Current Rating of 200kA RMS Sym. Typical Applications * 600Vac/dc or less Control Systems * 600Vac/dc or less Industrial Control * 600Vac/dc or less Individual Control Circuits Fig. No. 1 2 3 1 2 3 4 5 6 7 8 9 10 11 Poles 1 2 3 1 2 3 1 3 1 3 1 3 1 3 Wire Range C, CR #2-14 Cu, #2-8 Al COR #2-14 Cu Only P, PR, S, SR #10-14 Cu Only C, CR, #2-14 Cu/Al COR #4-14 Cu Only COR 1/0-8 Cu Only CR, CRQ 1/0-8 Cu/Al CR 250kcmil-6 Cu/Al CR 500kcmil -4 Cu/Al CR (2) 500kcmil-4/0 Cu/Al Clip reinforcing springs are standard on fuse blocks rated 100A and above. Available on 30A and 60A blocks by adding the letter "R" to the end of the part number. Copper only connections available by changing "CR" suffix to "COR". *No UL, No CSA Certification **UL Recognized, CSA Certification Dimensions - in (0.015) 2 - 60A 61-100A 1 2.415" 1.702 3.202 .750 2.250 4.702 2.250 .750 C L 5" 2.28" .30" 4.005 .94" 1.583" .22" Dia. .5" C'Bore 6.28" CL 3.14" 1.500 FIGURE 1. FIGURE 2. FIGURE 3. 1.75" FIGURE 4. Data Sheet: 1114 266 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 1.5" FIGURE 5. Fuse Holders and Blocks Class J Fuse Blocks 101-200A 3.15" 3.1" .75" 3" 2" .31" 3.06" 8.31" 7.00" .5" .75" C'Bore 6.125" .344" Dia. hole thru .750 Dia. c'bore 6.125" 1.69" .34" DIA. .750" FIGURE 7. FIGURE 6. 201-400A 4" 1" 3" 1.75" .56" 10.51" 4.00" 9.00" 6.00" .625" 3.5" 7.5" 7.50" .50" .344" Dia. hole thru .750 Dia. c'bore 2.00" .5" FIGURE 8. Fuse Holders & Blocks .75" C'Bore .34" DIA. 1.00" FIGURE 9. 401-600A 4.99" 4.987" 4" 1.75" 1" 14.144" 11.00" 1.125" .56" 3.25" 2.375" .344" Dia. hole thru .750 Dia. c'bore 8.875" .50" 8.875" 2.88" .75" C'Bore .34" Dia. 1.00" FIGURE 10. FIGURE 11. Data Sheet: 1114 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 267 Fuse Holders and Blocks Class J Fuse Blocks JP Series Dimensions - in (mm) 0.015" ( 0.40mm) Specifications Description: Pyramid style 3-pole fuse block for use with Class J fuses (Cooper Bussmann(R) LPJ, DFJ, JKS). Dimensions: See Dimensions illustrations. Ratings: Volts: -- 600Vac/dc Amps: -- 0-30A SCCR: -- 200kA RMS Sym. Agency Information: CE, UL Listed, UL 4248, Guide IZLT, File E14853, CSA Certified, C22.2 No. 39, Class 4225-04, File 47235. Flammability Rating: UL 94V0. Mounting: Panel or 35mm DIN rail mount. DIN-RAIL MOUNTING SCREW 8" (203.2mm) APART END STOPS - PREVENT BLOCK MOVEMENT WHEN CHANGING FUSES 4.00" MAX. (101.6mm) 3.75" (0.02) (95.3mm (0.50) 1.88" (47.6mm) 1.19" (30.2mm) 2.38" (60.4mm) 3.29" (83.6mm) To order DIN rail: Part# NDNA 100 (1 meter) or NDNA 200 (2 meter). Catalog Numbers With DIN Rail Adapter* Mounting Screws with Pressure Plate Aluminum X X Catalog Numbers Panel JP60030-3PR X JP60030-3CR X JP60030-3COR X JP60030-3PRA X X JP60030-3CRA X JP60030-CORA X *Adapter only for DIN rail - Cat No. JPA-3. Box Copper Only X X X Wire Range #10-14 Cu Only #2-14 Cu/Al #2-14 Cu Only #10-14 Cu Only #2-14 Cu/Al #2-14 Cu Only 2.78" 3.06" (70.6mm) (77.8mm) ADAPTOR FOR 35mm SYMMETRICAL DIN-RAIL MOUNTING 3.13" (79.5mm) Data Sheet:1108 JA60030 Add-a-pole Specifications Description: Adder fuse block to achieve number of poles desired, for use with Class J fuses (Cooper Bussmann LPJ, DFJ & JKS). Dimensions: See Dimensions illustrations. Ratings: Volts: -- 600Vac/dc Amps: -- 0-30A SCCR: -- 200kA RMS Sym. Agency Information: UL Listed, UL 4248, Guide IZLT, File E14853, CSA Certified, C22.2 No. 4248, Class 6225-01, File 47235. Flammability Rating: UL 94V0. Mounting: Panel or 35mm DIN rail mount. Features: Panel and DIN rail mount, adder block, retaining clip Amps Poles Screw Screw w/Retaining Clip 2 - 30 ADDER 1 2 3 JA60030-AS JA60030-1S JA60030-2S JA60030-3S JA60030-ASR JA60030-1SR JA60030-2SR JA60030-3SR 1 268 Pressure Plate JA60030-AP JA60030-1P JA60030-2P JA60030-3P Pressure Plate w/Retaining Clip JA60030-APR JA60030-1PR JA60030-2PR JA60030-3PR Dimensions - in (mm) Box Lug Box Lug w/Retaining Clip Wire Range (Cu Only) JA60030-AC JA60030-1C JA60030-2C JA60030-3C JA60030-ACR JA60030-1CR JA60030-2CR JA60030-3CR S, SR, P, PR 10 - 18 AWG C, CR, 10 - 14 AWG For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Holders and Blocks Class T Fuse Blocks - 300V T300 Specifications Description: T300 (300V) fuse blocks for use with Class T fuses (Cooper Bussmann(R) JJN). Dimensions: See Dimensions illustrations. Poles: 1 to 4 Ratings: Volts: -- 300Vac/dc Amps: -- 12 - 600A SCCR:-- 200kA RMS Sym. Agency Information: CE, UL Listed UL 4248, Guide IZLT, File E14853, CSA Certified, Class 6225-01, File 47235. Flammability Rating: UL 94V0. T30100-1CR T30030-2CR Features and Benefits * Provide 1-, 2- and 3-pole housing for 300Vac Class T fuses. * Short-Circuit Current Rating of 200kA RMS Sym. * Class T fuse blocks have a small foot print, providing substantial space savings in equipment T30600-1C Class T Fuse blocks (300V) Catalog Numbers Typical Applications * 300Vac/dc or less Control Systems * 300Vac/dc or less Individual Control Circuits Catalog Numbers Catalog Numbers Screw T30030-2SR T30030-3SR T30030-4SR T30060-2SR T30060-3SR T30060-4SR -- -- -- -- -- -- -- Box Lug T30030-2CR T30030-3CR T30030-4CR T30060-2CR T30060-3CR T30060-4CR T30100-1CR T30100-2CR T30100-3CR T30200-1C T30200-3C T30400-1C T30600-1C Dimensions - in 1.63" 0.72" 0.16" Amps 1/2-30 1 2-30 31-60 31-60 61-100 61-100 101-200 101-200 201-400 401-600 Poles 2 3 4 2 3 4 1 2 3 1 3 1 1 Fig. No. 1 1 Wire Range 1 CR #2-14 Cu/Al SR #10-18 Cu Only 2 2 1/0-8 Cu/Al 3 4 5 6 250kcmil-6 Cu/Al 600kcmil-2/0 Cu/Al (2) 600kcmil-4/0 Cu/Al Figure 1. 12-60A 0.69" T30030-S SECTION X-X C 1.03 1.03 2.06 2.06 3.09 3.09 SR #10-18 Cu CR #6-14 Cu/Al 1.63" 0.72" 0.16" A B 1.20" 0.91" Dimensions (in) A B 2.41 -- 2.41 -- 3.44 1.03 3.44 1.03 4.47 2.06 4.47 2.06 Fuse Holders & Blocks Catalog Numbers T30030-2 T30060-2 T30030-3 T30060-3 T30030-4 T30060-4 X Z 0.91" 2.75" 2.5" X Z 0.44" Full 0.20" Radius C T30060-C SECTION Z-Z Data Sheet: 1115 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 269 Fuse Holders and Blocks Class T Fuse Blocks - 300V Figure 2. 61 to 100A Figure 3. 101 to 200A 1.69" (1 POLE) 3.09" (2 POLE) 4.5" (3 POLE) 2.06" 0.84" 6" 1.41" (2 POLE) 2.81" (3 POLE) X 0.05" 3" 1.125" 0.28" DIAMETER 0.63" C'BORE 0.5" DEEP 1.69" 0.22" DIA. 0.52" C'BORE 0.55" DEEP 2.25" REF. 4.78" 2.25" 1.25" Z 3.06" 2.56" 2.39" 1.94" 0.81" Z X 0.38" 0.75" Figure 5. 201 to 400A Figure 4. 200A 4.87" 6" 1.695" 3" .996" 2.25" 1.25" 1.125" 0.63" A 0.28" DIAMETER 0.63" C'BORE 0.5" DEEP 2.75" A 1.84" 0.282" DIAMETER THRU HOLE 0.625" C'BORE 0.438" DEEP 3.06" 2.38" 0.81" 2.375" 0.625" 4.46" Figure 6. 401 to 600A 2.03" 5.75" 2.88" 1.5" 3.44" 2" 3" 3" 0.75" 0.33" DIAMETER 0.75" C'BORE 0.5" DEEP Data Sheet: 1115 270 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Holders and Blocks Class T Fuse Blocks - 600V T600 Specifications Description: T600 (600V) fuse blocks for use with Class T fuses (Cooper Bussmann(R) JJS). Dimensions: See Dimensions illustrations. Poles: 1 to 3 Ratings: Volts: -- 600Vac/dc Amps: -- 12 - 600A SCCR:-- 200kA RMS Sym. Agency Information: CE, UL Listed UL 4248, Guide IZLT, File E14853, CSA Certified, Class 6225-01, File 47235. Flammability Rating: UL 94V0. Features and Benefits * Provide 1-, 2- and 3-pole housing for 600Vac Class T fuses. * Short-Circuit Current Rating of 200kA RMS Sym. * Class T fuse blocks have a small foot print, providing substantial space savings in equipment Typical Applications * 600Vac/dc or less Control Systems * 600Vac/dc or less Individual Control Circuits T60600-1C T30030-2CR Catalog Numbers Screw T60030-1SR T60030-2SR T60030-3SR T60060-1SR T60060-2SR T60060-3SR -- -- -- -- -- -- -- Box Lug T60030-1CR T60030-2CR T60030-3CR T60060-1CR T60060-2CR T60060-3CR T60100-1C T60100-2C T60100-3C T60200-1C 1B0089* T60400-1C T60600-1C Catalog Numbers Fig. Amps Poles No. 1 1 1 1 2-30 1/2-30 2 3 1 2 2 31-60 2 31-60 3 1 3 3 61-100 2 61-100 3 101-200 1 44 101-200 3 201-400 1 5 401-600 1 6 Wire Range SR #10-18 Cu CR #2-14 Cu/Al CR #2-14 Cu/Al SR #10-18 Cu Only 2/0-14 Cu/Al 250kcmil-6 Cu/Al 600kcmil-2/0 Cu/Al (2) 600kcmil-4/0 Cu/Al * UL Listed, Guide IZLT, File E14853, CSA Certified Class 6225-01, File 21455M18 Fuse Holders & Blocks Dimensions - in Figure 1. 12 to 30A 1.44" 0.55" 0.5" 1.44" 0.33" 0.55" 2.59" 1.16" 0.33" 0.55" 3.75" 2.31" 0.33" 0.22" DIAMETER 0.5" C'BORE 0.33" 3.19" 1.563" 1.42" Figure 2. 31 to 60A 1.75" 0.59" 0.5" 1.81" 0.63" 0.59" 3.34" 1.53" 0.63" 0.59" 4.86" 3.06" 0.63" 0.22" DIAMETER 0.5" C'BORE 2.94" 1.63" 1.47" Data Sheet: 1116 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 271 Fuse Holders and Blocks Class T Fuse Blocks - 600V Figure 3. 61 to 100A 1.69" (1 POLE) 3.09" (2 POLE) 4.5" (3 POLE) 1.41" (2 POLE) 2.81" (3 POLE) 0.84" X 0.78" Z 0.22" DIA. 0.52" C'BORE 0.55" DEEP 2.34" REF. 2.39" X 0.38" Z SECTION Z-Z 0.75" Figure 4. 101 to 200A Figure 5. 201 to 400A 6" 6" 0.05" 3" 3" 1.125" 1.25" 2.25" 2.25" 1.25" 1.125" 2.5" 0.28" DIAMETER 0.63" C'BORE 0.5" DEEP 0.63" 0.28" DIAMETER 0.63" C'BORE 0.5" DEEP 2.72" 3.06" 2.56" 1.94" 0.81" 3.06" 2.38" 0.81" Figure 6. 401 to 600A 2.95" 6.75" 3.38" 1.5" 3.44" 2" 3" 3" 0.75" 0.33" DIAMETER 0.75" C'BORE 0.5" DEEP Data Sheet: 1116 272 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Holders and Blocks Add-a-pole Fuse Blocks BCA Series - Class CC fuses BMA Series - 1332" X 1 12" fuses Dimensions in 0.015" (mm 0.38mm) Adder Block Fuse Holders & Blocks Specifications Description: 1-, 2 and 3-pole fuse blocks for use with Class CC fuses (BCA Series use Cooper Bussmann(R) LP-CC, KTK-R, and FNQ-R), or with standard 1332" x 1 12" fuses (BMA Series 1-Pole use Cooper Bussmann(R) KTK, FNQ, FNM, BAF, PV and AGU) Both Series use an "adder block" to form multi-pole segmented blocks to achieve the desired number of poles. Dimensions: See Dimensions illustration. 2-Pole Poles: 1 to 3. Wire Range: #10-#18 Cu only. Terminals: Screw/quick connect* or pressure plate/quick connect*. Ratings: Volts: -- 600Vac/dc 3-Pole Amps: -- 110-30A SCCR: -- BCA Series: 200kA RMS Sym. BMA Series: 10kA RMS Sym. Agency Information: BCA Series: CE, UL Listed, UL 4248, Guide IZLT, File E14853. CSA Certified, C22.2 No. 4248, Class 6225-01, File 47235. BMA Series: CE, UL Recognized, UL 4248, Guide IZLT2, File E14853. CSA Certified, C22.2 No. 4248, Class 6225-01, File 47235. Flammability Rating: UL 94V0 *Quick connect rated for 20A maximum. Catalog Numbers BCA Series Catalog Numbers BCA603ASQ BCA6031SQ BCA6032SQ BCA6033SQ BCA603APQ BCA6031PQ BCA6032PQ BCA6033PQ BMA Series Poles Adder Block 1 2 3 Adder Block 1 2 3 Terminal Type Screw w/ quick connect Screw w/ quick connect Screw w/ quick connect Screw w/ quick connect Pressure plate w/ quick connect Pressure plate w/ quick connect Pressure plate w/ quick connect Pressure plate w/ quick connect Catalog Numbers BMA603ASQ BMA6031SQ BMA6032SQ BMA6033SQ BMA603APQ BMA6031PQ BMA6032PQ BMA6033PQ Poles Adder Block 1 2 3 Adder Block 1 2 3 Terminal Type Screw w/ quick connect Screw w/ quick connect Screw w/ quick connect Screw w/ quick connect Pressure plate w/ quick connect Pressure plate w/ quick connect Pressure plate w/ quick connect Pressure plate w/ quick connect Data Sheets: BCA Series 1154, BMA Series 1155 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 273 Fuse Holders and Blocks Class CC, Type M and Class G Fuse Blocks BC Series BM Series Type M Specifications Description: Class CC fuse blocks for use with Class CC fuses (Cooper Bussmann LP-CC, KTK-R, and FNQ-R). Dimensions: See Data Sheet 1105 Poles: 1 to 3 Ratings: Volts: -- 600V Amps: -- 110-30A SCCR:-- 200kA RMS Sym. Agency Information: CE, UL Listed (Guide IZLT, File E14853), CSA (Class 6225-01, File 47235) Flammability Rating: UL 94V0 DIN Rail Adapters: See page 413 for DRA-1 & DRA-2 Catalog Numbers Screw BC6031S BC6032S BC6033S Screw with Quick Connect* BC6031SQ BC6032SQ BC6033SQ Terminal Type Pressure Plate w/ Pressure Quick Plate Connect* BC6031P BC6031PQ BC6032P BC6032PQ BC6033P BC6033PQ Box Lug BC6031B BC6032B BC6033B Specifications Specifications Description: Supplementary fuse Description: Class G fuse blocks for use blocks for use with any 1332" x 112" fuses with Class G fuses (Cooper Bussmann SC). (Cooper Bussmann(R) KTK, FNQ, FNM, Dimensions: See Data Sheet 1106 BAF, PV, and AGU). Poles: 1 to 3 Dimensions: See Data Sheet 1104 Ratings: Poles: 1 to 3 Volts: -- 600Vac/dc (0-20A) DIN Rail Adapters: See page 413 -- 480Vac/dc (25-60A) for DRA-1 & DRA-2 Amps: -- 1-60A (See Catalog Numbers Ratings: table) Volts: -- 600Vac/dc SCCR: -- 100kA RMS Sym. Amps: -- 110-30A Agency Information: CE, UL Listed SCCR:-- 10kA RMS Sym. 35-60A (Guide IZLT, File E14853), UL Agency Information: CE, UL Recognized 1-30A, (Guide IZLT2, File Recognized (Guide IZLT2, File E14853), CSA (Class 6225-01, File 47235). E14853), CSA (Class 6225-01, File DIN Rail Adapters: See page 413 for 47235). DRA-1 & DRA-2. Flammability Rating: UL 94V0. Catalog Numbers Catalog Numbers Terminal Type Poles 1 2 3 Data Sheet: 1105 BCCM Series Screw with Quick Connect* BM6031SQ BM6032SQ BM6033SQ Terminal Type Pressure Plate w/ Quick Box Connect* Lug BM6031PQ BM6031B BM6032PQ BM6032B BM6033PQ BM6033B Recommended Cover Puller Description: 3-pole fuse block for use with (2) Class CC fuses and (1) 1332" x 112" fuse * PF1-WH (White) * PF1-BK (Black) Catalog Numbers Catalog Numbers BCCM6033SQ BCCM6033PQ BG & G Series Terminal Type Screw with Quick-Connect* Pressure Plate w/Quick-Connect* Poles 1 2 3 Screw with Quick Connect* BG3011SQ BG3012SQ BG3013SQ BG3021SQ BG3022SQ BG3023SQ BG3031S BG3032S BG3033S -- -- -- Pressure Plate w/ Quick Connect* BG3011PQ BG3012PQ BG3013PQ BG3021PQ BG3022PQ BG3023PQ BG3031P BG3032P BG3033P -- -- -- Box Lug w/retaining clip -- -- -- -- -- -- -- -- -- G30060-1CR G30060-2CR G30060-3CR Recommended Cover Puller * PF1-WH (White) * PF1-BK (Black) *Quick-connect terminal rated for 20A max. Recommended Cover Puller * PF1-WH (White) * PF1-BK (Black) Data Sheet: 1104 274 Box Lug BG3011B BG3012B BG3013B BG3021B BG3022B BG3023B BG3031B BG3032B BG3033B -- -- G30060-3C Data Sheet: 1106 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Amps 1 1-15 to 15 20 20 Poles 1 2 3 1 2 3 25 1 25-30 to 2 30 3 35 1 35-60 to 2 60 3 Fuse Holders and Blocks Modular Fuse Blocks BH Series Modular Type Fuse blocks for Class H & J Fuses BH Series Features and Benefits * BH fuse blocks provide a wide range of mounting configurations for Cooper Bussmann high speed fuses. * BH fuse blocks have a Short-Circuit Current Rating of any installed fuse up to 200kA RMS Sym. Typical Applications * Solid State Control Circuits * VFDs * UPS Systems Catalog Numbers BH-0001 BH-0002 BH-0003 BH-0111 BH-0112 BH-0113 BH-0121 BH-0122 BH-1001 BH-1002 BH-1003 BH-1131 BH-1132 BH-1133 BH-2001 BH-2002 BH-2003 BH-2031 BH-2032 BH-2033 BH-3003 BH-3004 BH-3033 BH-3144 BH-3145 Class H & J Features and Benefits * H & J modular fuse blocks provide three pole 30 and 60 amp ratings for specific client requirements for separate line and load fuse clip configurations. Typical Applications * Up to 60A, space confined, control circuits Screw 11241-3SR* 11242-3SR 11241-3SR 11242-3SR** 11239-3SR 11240-3SR** 11241-3SR 11239-3SR* Catalog Numbers Fuse Pressure Plate Class Volts 11241-3PR* H 250 250 11242-3PR 11241-3PR 600 H 11242-3PR** 11239-3PR 600 11240-3PR** 11241-3PR J 600 J 11239-3PR* Amps 60 60 35 35 60 60 35 60 Fig. No. 1 2 1 2 1 2 1 1 Note: Order two blocks per fuse (matched or mixed.) *11239 and 11241 have wire terminals and mounting holes located under fuse. (Figure 1) **11240 and 11242 have wire terminals and mounting holes located at end of fuse. (Figure 2) Refer to the data sheet numbers below for the catalog code description information. Data Sheet: (BH-0) 1200; (BH-1) 1201; (BH-2) 1202; (BH-3) 1203 Figure 1 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Figure 2 275 Fuse Holders & Blocks Specifications Description: For use with Cooper Bussmann(R) high speed fuses. Ratings: SCCR: -- 200kA RMS Sym. or fuse IR, whichever is lower. Agency Information: CE, UL Recognized, Guide EZLT2, File No. E14853 up to 700V, CSA Certified, Class 6225-01, File No. 47235 up to 700V. Specifications Description: 3-Pole only, modular type fuse blocks for Class H & J fuses with standard reinforced retaining clips. Ratings: Volts: -- 250V (0-60A See Catalog Numbers table) -- 600V (35-60A See Catalog Numbers table) Amps: -- 0-60A @ 250Vac/dc (See Catalog Numbers table) -- 35-60A@600V (See Catalog Numbers table) SCCR: -- Class J 200kA, Class H 10kA Agency Information: CE, UL Recognized, Guide IZLT2, File E14853, CSA Certified, Class 6225-01, File 47235. Fuse Holders and Blocks Box Cover Units for Plug Fuses SOU, SRU, SSN, SSU, SOW, SRW, SSW, SOX, SRX, SSX, SOY, SRY, SSY, SSY-RL, SSY-L, STY, SCY, SOY-B & SKA Specifications Description: Box covers for standard electrical boxes that provide fused outlet, fused switch or circuit fuse protection. Ratings: Volts: -- 125V/250V (See Catalog Numbers table) Amps: -- 0-15A (See Catalog Numbers table) Agency Information: CE, See Catalog Numbers table. Features/Benefits * Cooper Bussmann(R) Box Cover Units provide a low-cost method of controlling and protecting small motors when used with Cooper Bussmann(R) Type T, Fusetron(R) , dual-element fuses. * Provide low-cost supplementary protection and disconnection of 125V or less, single phase circuits. SOU SRU SSU Typical Applications * Fractional Horsepower, 125 Volt Single-Phase Motor Circuits * General 125 Volt Supplemental Circuits STY SSN Catalog Numbers Catalog Numbers SOU SRU SSU SOW SRW SSW SOX SRX SSX SOY SRY SSY SSY-RL STY3 Type Box Handy 22141"4"Handy 22343"4"Switch Switch 4"Octagon Octagon 4" Square 4"4"Square Fuse holder 3 Single Double X X X X X X X X X X X X X X SCY X SOY-B SKA SSN X X 1 2 3 4 41116" Square Single Gang X Receptacle Outlet to Load Switch 125V 250V Control1 Switch Light2 X X X X X X X X X X X X(2) X Motor Size (Max) 3 4hp 1 2hp 1 2hp 3 4hp 1 2hp 1 2HP 3 4hp 1 2hp 1 2hp 3 4hp 1 2hp 1 2hp 1 2hp 1 2hp 1 2hp (2) 4hp 2hp 1 2hp 3 X(15A) X X General Data 125V, 15A 125V, 15A 125Vac, (do not use on dc), 15A 125V, 15A 125V, 15A 125Vac, (do not use on dc), 15A 125V, 15A 125V, 15A 125Vac, (do not use on dc), 15A 125V, 15A 125V, 15A 125Vac, (do not use on dc), 15A 125Vac, (do not use on dc), 15A 125Vac, (do not use on dc), 15A 125Vac, (do not use on dc), can protect two motors, 15A 125V, protects two motors, 15A 250V, 15A single phase Weatherproof model, 15A Switch turns power to fused load OFF or ON. Switch light indicates power to load (dark when switch OFF or fuse open). Double pole switch opens both sides of circuit. Can be used for two separate motors with common switch or a single motor (34Hp, 250Vac max.). UL Guide JAMZ, File IE6491; CSA Class 6225-01, File 47235. Data Sheet: 1129 276 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Agency4 Listing/ Certification UL, CSA UL UL, CSA UL, CSA UL UL, CSA UL, CSA UL UL, CSA UL, CSA UL UL, CSA -- UL UL UL UL UL Fuse Holders and Blocks In-line Fuse Holders for 14" x 78" to 114" Fuses HFB & HFB-10 HHB HRK Specifications Description: Waterproof in-line fuse holder for 14" x 114" fuses. Dimensions: See Dimensions illustration. Construction: Thermoplastic rubber body with tin-plated, copper contacts. Ratings: Volts: -- 32V Amps: -- 30A max Specifications Description: Universal in-line fuse holder for 14" x 78", 1" and 114" fuses. Dimensions: See Dimensions illustration. Construction: Nylon body with tinplated, copper contacts. Ratings: Volts: -- 32V Amps: -- 30A max Flammability Rating: UL 94V2. Pull Force: 5lbs minimum to separate fuse holder housing with fuse installed. Specifications Description: Universal in-line fuse holder for 14" x 78" to 1 14" fuses. Dimensions: See Dimensions illustration. Construction: 8" (203mm) #14 lead wires. Ratings: Volts: -- 32V Amps: -- 15A max Catalog Numbers Description Standard Pack (10-in) Bulk Pack (100-in) HFB Replacement Contact Clip HFB-10** Replacement Contact Clip *HFB accepts #12 to #18 wire leads (not provided). See Data Sheet for recommended crimp tools. **HFB-10 accepts #10 wire leads (not provided). See Data Sheet for recommended crimp tools. Features/Benefits * Simple assembly with one-piece thermoplastic (important information molded into body) * High visibility yellow color for easy identification in dark or hard-to-access locations * Ideal for shock and vibration environments; withstands many organic solvents; temperature range -40/+150C Typical Applications * Supplemental, Low Voltage, Low Amperage Control Circuits Features and Benefits * HHB Universal in-line fuse holder for 1 4" x 78", 1" and 1 14" fuses. Typical Applications * Supplemental, Low Voltage, Low Amperage Control Circuits Catalog Numbers Holder -- without leads* - RoHS compliant Catalog Numbers Description HHB-R Standard Pack (10-in) BK/HHB-R Bulk Pack (100-in) *Accepts #12 to #16 wire leads (not provided with basic fuse holder). See Data Sheet for recommended crimp tools. Holder -- with pre-attached #14 Insulated lead wires - Not RoHS compliant unless noted Catalog Numbers Wire 19" Length 8" Length Color BK/HHB-Y419 BK/HHB-Y408 Yellow BK/HHB-R419 BK/HHB-R408** Red BK/HHB-B419 BK/HHB-B408 Black Features and Benefits * HRK Universal in-line fuse holder for 1 4" x 78", 1" and 114" fuses with #14 lead wires. * RoHS compliant Typical Applications * Supplemental, Low Voltage, Low Amperage Control Circuits Catalog Number Catalog Number HRK-R* Amp Rating Volts 15 32 Fuse Description 4" diameter fuses of different lengths. 1 *Three springs furnished with fuse holder to accommodate different length 14" fuses. Dimensions - in (mm) 2.19" (55.6mm) 0.75" (19.1mm) 0.69" (17.5mm) 1.56" (39.7mm) **RoHS compliant. 0.38" (9.5mm) Dimensions - in (mm) Dimensions - in (mm) Fuse Length 7 8" (AGW) 1" (AGX) 114" (AGC, MDL) 3" (76.2mm) Fuse Holder Length "L" 2.100 Max 2.250 Max 2.420 Max L 0.75" 0.53" (19.1mm) Data Sheet: 2102 (13.5mm) Data Sheet: 2103 Data Sheet: 2111 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 277 Fuse Holders & Blocks Catalog Numbers HFB* BK/HFB BK/1A2294 1A2294-01 Fuse Holders and Blocks In-line Fuse Holders HR and HM Series Specifications Description: In-line fuse holders for SFE and 14" dia. x various length fuses. Dimensions: See Dimensions illustration. Ratings: Volts: -- 32V Amps: -- 20A Features and Benefits * HR and HM Universal in-line fuse holder for SFE and various length 14" diameter fuses with #14 lead wires. Typical Applications * Supplemental, Low Voltage, Low Amperage Control Circuits Catalog Numbers Catalog Numbers HRJ* HRI HRH HRE HRG HRF HMJ** HMI HMH HME HMG HMF Includes Fuse SFE-20 SFE-14 SFE-9 SFE-712 SFE-6 SFE-4 SFE-20 SFE-14 SFE-9 SFE-712 SFE-6 SFE-4 Wire Length & Size 19" of #14 HHJ-B HHI-B 8" of #14 For 14" x 114" fuse, no wire or fuse included, accepts #18 - #22 wire. For 14" x 114" fuse, no wire or fuse included, accepts #12 - #16 wire. Specifications Description: In-line water-resistent fuse holders for 14" x 114" fuses. Dimensions: See Dimensions illustration. Construction: Phenolic body with copper crimp contact leads. Ratings: Volts: -- 250V Amps: -- 20A Agency Information: CE, UL Recognized, (Guide IZLT2, File E14853) UL. Flammability Rating: UL 94HB. Specifications Description: In-line fuse holders for 5 x 15mm or 5 x 20mm fuses. Dimensions: See Dimensions illustration. Construction: Black thermoplastic body with brass contacts, wire: 16 AWG, red. Ratings: Volts: -- 32V Amps: -- 5A (5 x 15mm) -- 10A (5 x 20mm) Typical Applications * Supplemental, Low Voltage, Low Amperage Control Circuits For 14" x 1116" fuse, no wire or fuse included, accepts #12 - #16 wire. Fuse Size 5 x 15mm & 5 x 20mm Dimensions - in 1/4" 1/32" 6-3/16" 1/4" Terminals Crimp #12 - #16 1 4" Quick Connect 1.84" WIRE LENGTH: 13" 0.5" Dimensions - in (mm) 0.42" DIA. 2.34" (59.5mm) 1.84" Dimensions - in (mm) .800" .600" (20.3mm) (15.2mm) 2.19" (55.6mm) 0.75" (19.1mm) 0.69" (17.5mm) 1.56" (39.7mm) Data Sheet: 2122 278 6-1/16" 1/4" (IN ASSEMBLED POSITION) *No UL Recognition. Symbol HHJ-A HHJ-B Typical Applications * Supplemental, Low Voltage, Low Amperage Control Circuits Catalog Numbers Refer to data sheet for recommend crimp tools Catalog Numbers HFA HFA-HH* Features and Benefits * HHT in-line fuse holders for 5 x 15mm and 5 x 20 mm fuses. Catalog Number HHT Catalog Numbers Replacement Contacts Catalog Number 9838 9841 HHT Series Features and Benefits * HFA in-line, water-resistent fuse holder for 14" x 114" fuses. * Also available as in-line fuse holder only with lead wire contacts, HRJ-LESS-Fuse. ** Also available as in-line fuse holder only with lead wire contacts, HMJ-LESS-Fuse. HHJ-A HFA Series 0.38" (9.5mm) Data Sheet: 2115 Data Sheet: 2138 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Holders and Blocks TronTM In-line Fuse Holders HEG Series HEH Series HEC Series HEJ Series Specifications Description: Single-pole, non-breakaway, in-line fuse holders for Type SC fuses, 480V (or less). Ratings: Volts: -- 600V Amps: -- 0-15A Fuse Size: 1332" x 1.31" Specifications Description: Single-pole, non-breakaway, in-line fuse holders for Type SC fuses (Also fuse types BBS & KTQ, nominal size 1332" x 1 38"). Ratings: Volts: -- 600V Amps: -- 0-20A Agency Information: CSA - 15A. Specifications Description: Single-pole, non-breakaway, in-line fuse holders for Type SC-25, & SC-30 fuses, size 13 32" x 1 58". Ratings: Volts: -- 480V Amps: -- 0-30A Specifications Description: Single-pole, non-breakaway, in-line fuse holders for Type SC and Type HVW fuses, size 1332" x 2 14". Ratings: Volts: -- 480V Amps: -- 35-60A Type SC -- 12-6A Type HVW Catalog Number HEG-AA Catalog Numbers Optional Boots: HEH-AA, HEH-BB, HEH-AD 2A0660 Single Conductor 2A0661 Two Conductor Optional Boots: Catalog Numbers HEC-AA, HEC-RW-RLB-R Optional Boots: 2A0660 Single Conductor 2A0661 Two Conductor Catalog Numbers HEJ-AA, HEJ-AB, HEJ-AC, HEJ-BB, HEJ-JJ, HEJ-JK, HEJ-LL, HEJ-LLB, HEJ-CC, HEJ-DD, HEJ-WW, HEJ-PP, HEJ-QQ Optional Boots: 2A0660 Single Conductor 2A0661 Two Conductor Fuse Holders & Blocks 2A0660 Single Conductor 2A0661 Two Conductor Data Sheet: 2124 Data Sheet: 2124 Data Sheet: 2124 Data Sheet: 2123 HEB Series HET Series HEY Series HEX Series Specifications Description: Double-pole in-line fuse holders for KTKR fuses with optional breakaway receptacle, polarized, and accepting Class CC branch circuit fuses (Cooper Bussmann(R) KTK-R, FNQ-R & LP-CC; 600V or less, 200,000A IR). Ratings: Volts: -- 600V Amps: -- 0-30A Specifications Description: Double-pole inline fuse holders for 1332" x 1 12" fuses (typically fuse types BAF, FNM, FNQ, and KTK 1 10 - 30A). Ratings: Volts: -- 600V Amps: -- 0-30A Specifications Description: Single-pole in-line fuse holders for any 13 32" x 1 12" fuses (typically fuse types: BAF, FNM, FNQ, and KTK 110 - 30A). Ratings: Volts: -- 600V Amps: -- 0-30A Catalog Numbers See Page 280 Specifications Description: Single-pole in-line fuse holders for 13 32" x 1 12" fuses with a permanently solid neutral identified by white plastic coupling nut. Catalog Numbers HET-AA, HET-AB, HET-AW, HETAW-RLC-A, HET-AW-RLC-B, HETAW-RLC-C, HET-AW-RLC-J, HETAW-RYC, HET-BB, HET-BW-RLC-B, HET-BW-RYC, HET-JJ, HET-JK, HET-JW, HET-JW-RLC-J, HET-JWRYC, HET-KK Catalog Numbers HEY-AA, HEY-AB, HEY-AC, HEYAD, HEY-AE, HEY-AL, HEY-AWDRLC-A, HEY-AW-DRLC-B, HEYAW-DRYC, HEY-BB, HEY-JJ Data Sheet: 2127 Data Sheet: 2125 Data Sheet: 2126 Catalog Numbers HEX-AA, HEX-AB, HEX-AC, HEX-AD, HEX-AE, HEX-AW, HEX-AW-DRLC-A, HEX-AW-DRYC, HEX-AW-RLC-A, HEX-AW-RYC, HEX-AY, HEX-BB, HEX-CC, HEX-JJ, HEX-JK, HEX-JWDRYC, HEX-KK Data Sheet: 2126 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 279 Fuse Holders and Blocks For HEB Holders Only Directions: To select complete holder P/N, work from left to right starting with loadside terminal options and then lineside terminal options. Then determine breakaway or non-breakaway style. Loadside Terminal Lineside Terminal Available P/N's Terminal Type No. of Terminal Wire Size Wires per Solid Stranded Wire Wire Type Terminal No. of Wire Size Wires per Solid Stranded Wire Terminal Wire Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Setscrew Copper Setscrew Copper Setscrew Copper Setscrew Aluminum Setscrew Aluminum Crimp Aluminum Crimp Aluminum Crimp Aluminum Crimp Aluminum Crimp #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #6 #10 #6 #10 #6 #10 #6 #10 #4 #8 #2 #6 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y #12 to #8 #12 #6 #10 #4 #8 #2 #6 2/0 #3 1 2 1 2 1 2 1 2 1 2 Y Y Y Y N Y N Y N N Y Y Y Y Y Y Y Y Y Y #12 to #3 1 Y #12 to #3 2 #12 to #2 #12 to #2 #20, #18 1 Y Y #12 to #3 1 Y Y #12 to #3 1 Y Y #12 to #3 1 Y Y #12 to #3 1 Y Y #12 to #2 1 Y Y #8 #6 #6 #4 #3, #4 #2 1 1 1 1 1 1 N Y N Y N Y Y N Y N Y N #1, #2 1 N Y 1/0 1 N Y 1 Y N 1 N Y SolidTerminal #8 to #12 for aluminum connector #10 to #14 (1)UL Recognized, Guide IZLT2, File E14853 (2)CSA Certified, Class 6225-01, File 47235 (3)CE (4)HEB-AW-RLC-C is for (1) #4 stranded wire only. 280 Copper Crimp Copper Crimp Copper Crimp (4) Copper Crimp Copper Crimp Copper Setscrew Copper Setscrew Aluminum Setscrew Aluminum Setscrew Aluminum Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Setscrew Copper Setscrew Aluminum Setscrew Aluminum Setscrew Aluminum Setscrew Aluminum Crimp Aluminum Crimp Aluminum Crimp Aluminum Crimp Aluminum Crimp Non-Breakaway P/N Breakaway P/N (Boots not included) (Boots included) HEB-AA(1)(2) (3) HEB-AW-RLC-A(1)(2) (3) HEB-AB(2) HEB-AW-RLC-B HEB-AC(2) HEB-AW-RLC-C(4) HEB-AD(2) N/A HEB-AE(2) N/A Y HEB-AJ HEB-AW-RLC-J Y Y HEB-AK HEB-AW-RYC 1 Y Y HEB-AL HEB-AW-RLA 2 Y Y HEB-AY HEB-AW-RYA #1, #2 1 N Y HEB-AR N/A #12 to #8 #12 #6 #10 #4 #8 #2 #6 #4 #8 #2 #6 #12 to #8 #12 1 2 1 2 1 2 1 2 1 2 1 2 1 2 Y Y Y Y N Y N Y N Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y HEB-BA(2) HEB-BW-RLC-A HEB-BB(2) HEB-BW-RLC-B HEB-BC(2) N/A HEB-BD(2) N/A HEB-CC(2) N/A HEB-DD(2) N/A HEB-ZA N/A #12 to #3 1 Y Y HEB-JJ HEB-JW-RLC-J #12 to #3 2 Y Y HEB-JK HEB-JW-RYC #12 to #2 1 Y Y HEB-JL N/A #12 to #2 2 Y Y HEB-JY N/A #12 to #2 1 Y Y HEB-LL HEB-LW-RLA #8 #6 #6 #4 #3, #4 #2 1 1 1 1 1 1 N Y N Y N Y Y N Y N Y N HEB-NN N/A HEB-PP(2) N/A HEB-QQ(2) N/A #1, #2 1 N Y HEB-RR(2) N/A 1/0 1 N Y HEB-TT(2) N/A 1 Y N 1 N Y HEB-SS N/A SolidTerminal #8 to #12 for aluminum connector #10 to #14 Insulating boots for single conductor-2A0660 Dual conductor-2A0661 Contact your local Cooper Bussmann representative for other possible terminations not listed. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Data Sheet: 2127 Fuse Holders and Blocks Panel Mounted Fuse Holders for 5 x 20mm Fuses HTC-35M 37.5mm 12.70mm +0.0 -0.1 O15mm 4mm 5.5mm HTC-40M Data Sheet: 2110 11mm 12.70mm +0.0 -0.1 6.5mm Data Sheet: 2110 36mm HTC-55M 12.00mm +0.0 -0.1 3.0x0.51mm O15mm O22mm 37.5mm Ratings: Volts: -- 250Vac Amps: -- 10A UL, 6.3A VDE Fuse Access: Screwdriver slot 12.00mm +0.0 -0.1 3.0x0.51mm O16mm Ratings: Volts: -- 250Vac Amps: -- 10A UL, 6.3A VDE Fuse Access: Threaded cap 12.00mm +0.0 -0.1 3.0x0.51mm O15mm Ratings: Volts: -- 250Vac Amps: -- 10A UL, 6.3A VDE Fuse Carrier: Bayonet type 12.70mm +0.0 -0.1 O16mm 0.5mm 4mm 5.5mm 11mm 35.5mm Data Sheet: 2110 10.2mm 12.00mm +0.0 -0.1 Specifications Terminals: Molded Materials: Solderability: Agency Information: Electrical: Shock Safety: Packaging: O15mm Ratings: Volts: -- 250Vac Amps: -- 10A UL, 6.3A VDE Fuse Carrier: Bayonet type 4.8x0.51mm 0.5mm 4mm 5.5mm 11mm Fuse Holders & Blocks HTC-70M 12.70mm +0.0 -0.1 O16mm Data Sheet: 2110 Tin-plated brass. High temperature thermoplastic that meets the flammability ratings of UL 94V0; Glow Wire Test: 960C per IEC 60695-2-1. In accordance with IEC 68-2-20. cURus, VDE Contact Resistance: 10 megohm; Insulation Resistance: 10M; Dielectric Strength 2000Vac. PC2 (fuse holders). Standard Qty 10 (No Prefix), Bulk Qty 100 (Prefix Catalog Number with BK/). For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 281 Fuse Holders and Blocks Panel Mounted Fuse Holders for 14" x 114" Fuses HKP, HKP-L, HKP-W HKP-BBHH, HKP-HH and HKP-LW-HH HKP-OO Specifications Description: Standard fuse holders. Dimensions: See Dimensions illustration. Ratings: Volts: -- 250V Amps: -- 30A Specifications Description: Fuse holders with 14" quick-connects. Dimensions: See Dimensions illustration. Ratings: Volts: -- 250V Amps: -- 15A Catalog Numbers Specifications Description: Snap-lock fuse holders. Dimensions: See Dimensions illustration. Ratings: Volts: -- 250V Amps: -- 30A Catalog Numbers Catalog Numbers Catalog Numbers HKP HKP-L HKP-W Fuse Description -- HKP w/ 2250V stand-off barrier HKP w/ drip-proof knob Catalog Numbers HKP-BBHH HKP-HH HKP-LW-HH Dimensions - in (mm) Fuse Description HKP w/ 14" quick-connects, nut and washer assembled. HKP w/ 14" quick-connect. HKP w/ drip-proof knob, 2250V stand-off barrier and 14" quick-connects. Catalog Number HKP-OO Fuse Description HKP with snap-lock Dimensions - in (mm) .75" (19.1mm) 1.56" (39.7mm) SE F US E FU Dimensions - in (mm) .855" (21.7mm) 1.17" FUSE .800" (20.3mm) Punched Mounting Hole .890" (22.6mm) .811" (20.6mm) Data Sheet: 2106 Specifications Data Sheet: 2106 Terminals: Agency Information: Replacement Parts: 282 Data Sheet: 2106 Bayonet-type knob. Vibration resistant. For panels up to 516" (7.9mm) thick. CE (HKP, HKP-L, HKP-W, HKP-OO), UL Recognized -- Guide IZLT2, File E14853, CSA Certified -- Class 6225-01, File 47235 Cap: 9435-1/2 Plastic Nut: BK/1A4287 (100 pieces minimum) Metal Nut: BK/1A4806-2 (100 pieces minimum) Washer: 9732 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Holders and Blocks Panel Mounted Fuse Holders for 5 x 20mm and 14" x 1 14" Fuses HTB Series Specifications Description: Fuse holders with knob-type carriers. Dimensions: See Dimensions illustrations. Construction: High temperature, flame retardant thermoplastic; UL Component Recognized; UL 94V0; mounting nut, spacer-black polycarbonate. Terminals: tin-plated brass. Electrical Data: Insulation resistance (per IEC #257) -- 10,000 ohms @ 500Vdc; contact resistance (per IEC #257) -- 0.005 ohms Max @ 1A; standoff voltage (per IEC #257) -- 480V/Mil @ 0.125" thickness. Agency Information: CE, UL Recognized -- Guide IZLT2, File E14853, 14 dia fuse @ 20A, 5mm dia fuse @16A @ 250V, CSA -- 16A @ 250V Class 6225-01 File 47235; VDE Certified: 136128, HTB-XXM, SEMKO Certification: Ref. #0146149/01, HTB-XXM. Mounting: Withstands 15 to 20 Lb-In torque to mounting nut when mounting fuse holder to panel. Environmental: Maximum operating temperature -55C to 85C. Replacement Parts Dimensional Data - in (mm) Knob Type Carrier Terminal Options Maximum Panel Thickness Common Dimensions: Length (Knob Type) - 1.69" (42.9mm) Plus In-Line Terminal NOTE: Plus In-Line Terminal 0.47" 1.125" (11.9mm) (28.6mm) Fuse Holders & Blocks Solder/ 3 16" Quick-Connect Carrier Options 4" Quick-Connect 1 4" x 114" 5 x 20mm ("I" Equals Inches) ("M" Equals Metric) Knob Knob 1 In-Line 0.34" 8.7mm) Rt. Angle 0.33" (8.3mm) In-Line 0.47" (11.9mm) HTB-26I-R Rt. Angle 0.45" (11.5mm) 0.30" HTB-22I-R HTB-24I-R HTB-28I-R 7.62mm HTB-22M-R HTB-24M-R HTB-26M-R HTB-28M-R 0.125" HTB-42I-R HTB-44I-R 3.18mm HTB-42M-R HTB-44M-R HTB-46M-R HTB-48M-R 0.30" HTB-62I-R HTB-64I-R 7.62mm HTB-62M-R HTB-64M-R HTB-66M-R HTB-68M-R 0.125" HTB-82I-R HTB-84I-R 3.18mm HTB-82M-R HTB-84M-R HTB-86M-R HTB-88M-R X X 0.09" NOM. (2.4mm) 0.69" 0.91" (17.5mm) (23.0mm) 0.67" 0.92" (17.1mm) (23.4mm) 0.47" 1.125" (11.9mm) (28.6mm) HTB-46I-R HTB-66I-R HTB-86I-R HTB-48I-R HTB-68I-R HTB-88I-R X X X X X Fuse holders and fuse carriers may be ordered separately. For product data sheets, visit www.cooperbussmann.com/products/datasheets/ulcsa X Data Sheet: 2119 283 Fuse Holders and Blocks Panel Mounted Fuse Holders for 5 x 20mm and 14" x 1 14" Fuses HTB Series Dimensional Data - in (mm) Screwdriver Type Carrier Terminal Options Carrier Options Solder/ 3 16" Quick-Connect Maximum Panel Thickness Common Dimensions: (Screwdriver Slotted) 1.75" (44.5mm) NOTE: Plus In-Line Terminal 0.17" 1.58" (4.37mm) (40.03mm) In-Line Rt. Angle 0.34" 4" Quick-Connect 1 0.47" 0.33" 8.7mm) Rt. Angle In-Line 0.45" (11.9mm) (8.3mm) 1 4" x 1 14" 5 x 20mm ("I" Equals Inches) ("M" Equals Metric) Screwdriver Screwdriver (11.5mm) 0.30" HTB-32I-R HTB-34I-R HTB-36I-R HTB-38I-R 7.62mm HTB-32M-R HTB-34M-R HTB-36M-R HTB-38M-R 0.125" HTB-52I-R HTB-54I-R 3.18mm HTB-52M-R HTB-54M-R HTB-56M-R HTB-58M-R 0.125" HTB-92I-R HTB-94I-R 3.18mm HTB-92M-R HTB-94M-R HTB-96M-R HTB-98M-R X X HTB-3 0.41" 1.34" (10.31mm) (34.13mm) HTB-5 0.17" 1.59" (4.37mm) (40.08mm) HTB-9 HTB-56I-R HTB-96I-R HTB-58I-R HTB-98I-R X X X X Catalog Number Build-A-Code FUSE CARRIER ONLY HTBS Packing Blank (Std.) - 10 fuse holders in a carton BK - 100 fuse holders in a cardboard shelf package Product Symbol Body Configuration and Mounting Knob Holders 2 -- Low Profile (Rear Panel Hex-Nut) 4 -- High Profile 6-- * (Front Panel Hex-Nut) 8 -- Low Profile (Snap-In) Screwdriver Slotted Holders 3 -- Low Profile 5 -- High Profile 9 -- Low Profile (Snap-In) Fuse Carrier I -- 1/4 x 1 1/4 M -- 5 x 20mm Rear Terminal Configuration 2 -- Solder / 3/16 Quick-Connect (In-Line) 4 -- Solder / 3/16 Quick-Connect (Right Angle) 6 -- 1/4 Quick-Connect (In-Line) 8 -- 1/4 Quick-Connect (Right Angle) P Splash Proof Cap with O-Ring (Optional on Knob Holders Only) -R RoHS Compliant Packaging (Blank) - Std. BK/ - Bulk Product Symbol FT -- Knob Type (For 20, 40, 60, and 80 Series Only) ST -- Screwdriver Slotted (For 30, 50, and 90 Series Only) *Profile varies with panel thickness. Holder installs through rear of panel. Data Sheet: 2119 284 For product data sheets, visit www.cooperbussmann.com/products/datasheets/ulcsa Fuse Carrier I -- 1/4 x 1 1/4 M -- 5 x 20mm Fuse Holders and Blocks Panel Mounted Fuse Holders for Indicating Type Fuses HLD HJL HK Series Specifications Description: Pin indicating for 1 4" x 114" fuses. Dimensions: See Dimensions illustration. Ratings: Volts: -- 250V Amps: -- 15A Agency Information: CE, UL Recognized, File E14853, Guide IZLT2. Specifications Description: Neon lamp indicating for 1 4" x 1" fuses. Dimensions: See Dimensions illustration. Ratings: Volts: -- 250V Amps: -- 15A Agency Information: None Specifications Description: Neon and incandescent lamp indicating for 14" x 114" fuses Dimensions: See Dimensions illustration. Ratings: Volts: -- 250V Amps: --15A (HKL, HKL-X) -- 20A (HKR, HKT, HKU, HKX) Agency Information: CE, UL Recognized, (Guide IZLT2, File E14853), CSA Certified (Class 6225-01, File 47235). Catalog Numbers Catalog Numbers* HLD HLD-HH Terminals Solder terminals 1 4" quick-connect terminals *Use w/GBA, GLD Fuses. Catalog Number Catalog Number* HJL Lamp Volts Color 90 to 250 Clear Knob Type Oct *Use with AGX or MKB fuses, for panels up to 18" thick. Catalog Numbers Dimensions - in (mm) 2.81" (71.4mm) 1.19" (30.2mm) 2.5" (HLD) (63.5mm) 0.81" (20.6mm) 0.69" (17.5mm) Octagonal Sides Octagonal Sides (69.9mm) (16.0mm + .13mm) Knob Color/Type Clear/Oct Clear/FS Amber/Oct Amber/Oct Red/Oct Amber/FS * Neon lamp -- UL Recognized and CSA Certified. ** Incandescent lamp. 2.75" (HLD-HH) Punched Mounting Hole Punched Mounting Hole .505" + .005" Lamp Volts 90-250 90-250 22-30 13-22 4-6 22-33 Dimensions - in (mm) .630" + .005" (16.0mm + .13mm) 2.81" .590" + .003" (14.6mm + .08mm) .473" + .005" (71.4mm) Flat-Sides 1.19" (30.2mm) (12.0mm + .13mm) 0.81" (20.6mm) Octagonal Sides Punched Mounting Hole .630" + .005" (16.0mm + .13mm) .573" + .003" (14.6mm + .08mm) Data Sheet: 2120 Data Sheet: 2121 Data Sheet: 2105 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 285 Fuse Holders & Blocks Dimensions - in (mm) Catalog Numbers HKL* HKL-X* HKR** HKT** HKU** HKX** Fuse Holders and Blocks Panel Mounted Fuse Holders for 1332" x 1 516" to 1 12" Fuses HPF HPS HPG HPD #10 wire max for solder connection Specifications Description: Standard fuse holders with screw-type knob for 1332" x 1516" to 112" Fuses. Dimensions: See Dimensions illustration. Agency Information: CE, UL Recognized, Guide IZLT2, File E14853; CSA Certified, Class 6225-01, File 47235. Flammability Rating: UL 94HB. Terminals: Combination 14" quick-connect/solder terminals. Catalog Numbers Catalog Numbers HPF HPF-C HPF-L HPF-EE HPF-JJ HPF-FF1 HPF-RR Amp Ratings 302 303 5 15 20 302 302 Volts 600 6003 600 600 600 480 600 HPF-WT 302 600 1 2 3 Specifications Description: Standard fuse holders with bayonet-type knob for 1332" x 1516" to 112" fuses. Dimensions: See Dimensions illustration. Agency Information: CE, UL Recognized, Guide IZLT2, File E14853; CSA Certified, Class 6225-01, File 47235. Flammability Rating: UL 94HB. Terminals: Combination 14" quickconnect/solder terminals. Catalog Numbers Fuse Description 1 12" (38.1mm) 1 12" (38.1mm) clear knob. BBS, 1332" x 1 38" fuses. SC 0-15, 1332" x 1 516" fuses. SC 20, 1332" x 1 1332" fuses. SC 25 & 30, 1332" x 1 58" fuses. KTK-R, LP-CC & FNQ-R Class CC fuses. Splash-proof knob. 1332" x 1 12" (38.1mm) No CSA Certification 20A max when used with quick-connect terminals. HPF-C ratings for CSA-15A, 250V Dimensions - in (mm) Catalog Symbol HPS HPS-L HPS-EE* HPS-JJ* HPS-F-EE1 Amp Ratings 30 2 3 5 15 20 15 Volts 600 600 600 600 600 Fuse Description 32" x 1 12" BBS, 1332" x 1 38" fuses. SC 0-15, 1332" x 1 516" fuses. SC 20, 1332" x 1 1332" fuses. Sleeve on body, leaded for 13 32" x 1516" fuses. 1 2 HPS-FF* 30 480 SC 25 & 30, 1332" x 1 58" fuses. HPS-RR*1 30 2 600 KTK-R, LP-CC, FNQ-R Class CC fuses. *-EE, -JJ, -FF and -RR versions are UL Recognized for applications requiring branch circuit protection. 1 No CSA Certification 2 20A max when used with quick-connect terminals. 3 HPS rated at 250V for CSA 13 Specifications Description: Standard fuse holders with bayonet-type knob for 1332" x 112" fuses. Dimensions: See Dimensions illustrations. Agency Information: CE, UL Recognized, (Guide IZLT2, File E14853). Flammability Rating: UL 94V0 - fuse holder body UL 94HB - Knob. Catalog Numbers Catalog Amp Numbers Ratings Volts Fuse Description 13 HPG* 301 600 32" x 1 12" fuses HPG-EE* 15 600 SC 0-15, 1332" x 1 516" fuses. 13 HPD** 301 600 32" x 1 12" fuses 1 20A max when used with quick-connect terminals. *HPG and HPG-EE has combination 14" quick-connect/solder terminals on both side (load) and rear (line) terminals. **HPD has combination 14" quick-connect/solder terminal on side (load) terminal only. Rear (line) terminal is 316" shorter than HPG. Rear terminal solder only. Dimensions - in (mm) HPG, HPG-EE 0.88" (22.2mm) 1.125" Dimensions - in (mm) (28.6mm) With Fuse 2.81" Max. (71.4mm) E USE FU With Fuse SE F 1.00" 1.31" 2.81" 1.78" HPD (71.4mm) (25.4mm) (33.3mm) (45.2mm) 0.88" FUS (22.2mm) 0.180" DIA. 1.125" (4.6mm) (28.6mm) 0.88" 1.78" (22.2mm) 0.250" 0.003" (6.35 .08mm) (Typ.2) (45.2mm) 2.69" Max. (68.3mm) Without Fuse 0.250" .003" (6.35 .08mm) (Typ.2) 0.180" (4.6mm) 1.125" (28.6mm) 0.80" (20.2mm) 2.41" (64.3mm) Without Fuse Data Sheet: 2114 286 Data Sheet: 2113 2.81" (71.4mm) Data Sheet: 2108 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Holders and Blocks Panel Mounted Fuse Holders for 1332" x 1 12" Fuses HPM HPC-D HPS2 #10 wire max for solder connection Specifications Description: Standard fuse holder with screw-type knob for 1332" x 112" fuses. Dimensions: See Dimensions illustration. Ratings: Volts: -- 600Vac/dc Amps: -- 30A1 1 20A max when used with quick-connect terminals. Catalog Numbers Catalog Numbers HPM HPM-D Description 4" quick-connect/solder Splash-resistant knob 2 1 2 HPM-D has 14" quick-connect/solder terminal on rear (load) terminal only. The side (line) terminal is 14" quickconnect only. 1 20A max when used with quick-connect terminals. Agency Information: CE, UL Recognized, Guide IZLT2, File E14853. Flammability Rating: UL 94HB. Catalog Numbers Catalog Number HPC-D Description Mount in panels up to 14" thick. Replacement knob - BK/9987SA Dimensions Specifications Description: For fuse size 1332" x 112", meeting UL 1598 requirement that both poles be removed simultaneously. Dimensions: See Dimensions illustration. Ratings: Volts: -- 600V@30A Amps: -- 0-30A 1 1 20A max when used with quick-connect terminals. Agency Information: UL 4248 recognized, (Guide IZLT2, File E14853), CSA certified: (Class 6225-01, File 47235). Flammability Rating: UL 94V0. Terminals: 14" quick-connect/solder. Catalog Numbers Catalog Numbers HPS2 BK/HPS2 Standard 10-in carton Bulk 100-in carton With Fuse 2.48" (63.1mm) Dimensions Dimensions 0.88" (22.2mm) With Fuse 2.73" (69.5mm) 1.775" 0.94" (45.1mm) (23.8mm) 0.180" 1.41" (4.6mm) (30.6mm) 1.120" (30.5mm) 2.594" (65.89mm) Without Fuse Mounting Hole Flange Rear of Panel Mounting Hole Flange Front of Panel 1.031" + 0.003" 0.250" 0.003" (6.35 0.08mm) (26.2mm + 0.08mm) 0.187" + 0.002" (4.75mm + 0.05mm) Nut Torque: 30 lb-in. Replacement Knob: Catalog Number: BK/9789-Y2 (50 pieces) Data Sheet: 2112 1.312" + 0.003" (33.3mm + 0.08mm) Data Sheet: 2109 0.890" + 0.003" (22.6mm + 0.08mm) 1.312" + 0.003" (33.3mm + 0.08mm) Panel Mount Hole Dimensions Data Sheet: 2140 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 287 Fuse Holders & Blocks Agency Information: CE, UL Recognized, Guide IZLT2, File E14853; CSA Certified, Class 6225-01, File 47235. Flammability Rating: UL 94HB. Specifications Description: Fuse holder with screw-type knob for 1332" x 112" fuses. Supplied with O-ring and panel gasket. Dimensions: See Dimensions illustration. Ratings: Volts: -- 600Vac/dc Amps: -- 30A1 Fuse Holders and Blocks Fuse Blocks for 14" x 1 14" Fuses Series 8000 Single-Pole Fuse Blocks Specifications Description: Bolt-in and snap-in mounting for 14" x 114" fuses. Construction: Blocks are molded flame retarded thermoplastic. Clips are spring-bronze. Ratings: Volts: -- 300V Amps: -- 25A (See Catalog Numbers table) Agency Information: CE, UL Recognized ; File E14853, Guide IZLT2, CSA Certified Class 6225-01, File 47235. Anti-Rotation Pin: Single-pole blocks may be ordered without the anti-rotational pin simply by adding an "X" to the number of poles (Example: BK/S-8000-1X). Carton Quantity: 10; shelf package: 100. Bulk Carton: Single-pole and 2-pole fuse blocks - 1,000; Multiple-pole fuse blocks - 3- to 8-pole: 200; 9- to 12-pole: 50. When ordering bulk quantities, prefix "BK/" to catalog number: (Example: BK/S-8001-1-SNP). Catalog Numbers Bolt-in Mounting Basic Catalog Numbers S-8001S-8002S-8101S-8102S-8201S-8202S-8203S-8301- Snap-in Mounting Catalog Numbers S-8001-1-SNP S-8002-1-SNP S-8101-1-SNP S-8102-1-SNP S-8201-1-SNP S-8203-1-SNP Series 8000 8000 Terminal Solder 8100 8100 16" Quick Connect 1 4" Quick Connect Side Screw 3 8200 8200 8300 8300 Series 8000 8000 8100 8100 8200 8200 Terminal Solder 16" Quick Connect 1 4" Quick Connect 3 Catalog Number Build-A-Code Angle 0 40 0 40 0 40 -- Angle 0 40 0 40 0 Side Agency Maximums UL 25A CSA 21A UL 20A CSA 13A UL 20A CSA 16A Poles (Suffix) 1 - 12 4405 - 0 Solder terminals with integral terminal and clip Dimensions - in (mm) 2.31" (58.7mm) 0.69" (17.5mm) 0.27" (6.7mm) 1.63" (41.3mm) 4406 - Side solder terminal 4574 - Spare fuse block Dimensions - in (mm) 1 - 12 1.63" (41.3mm) 0.69" UL 30A CSA 25A (17.5mm) Agency Maximums UL 25A CSA 21A UL 20A CSA 13A UL 20A CSA 16A Catalog Code BK/ S-8 0 Specifications Description: Single-pole fuse block for 14" x 114" (6.4 x 31.8mm) size fuses. Dimensions: See Dimensions illustrations. Construction: Bakelite base width 12" (12.7mm); springbronze, bright tin-lead plate clips. Ratings: Volts: -- 250V Amps: -- 30A Poles (Suffix) Available Available only in only in single single pole pole 00 -00 0.27" (6.7mm) 2499 - Dimensions - in (mm) Prefix for Bulk Packing Series 8000 Product Line Type Terminal "0"-Solder "1"-/ Quick Connect "2" - / Quick Connect "3" - Screw Terminal Angle "01" - straight (0) "02"- 40 "03" - side* Number of Poles (1-12) Data Sheet: 2101 288 Side quick-connect Agency Information: UL Recognized, Guide IZLT2, File E14853 Terminals: 14" (6.4mm); 15A, 250V 1.63" 0.75" (41.3mm) (19.1mm) 0.27" 0.72" (6.7mm) (18.3mm) 0.5" (12.7mm) Note: Mounting screw hole diameter is 0.147" (3.7mm). Counterbore diameter, 0.636" (8.0mm). Max Mounting Screw No. 6. *Available only in single pole For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Holders and Blocks Fuse Blocks for 14" x 1" Fuses 3828 Series 4520 and 4393 Specifications Description: Fuse block for 14" x 1" (6.4 x 25.4mm) fuses with solder terminals. Dimensions: See Dimensions illustration. Ratings: Volts: -- 250V Amps: -- 30A Mounting: Mounting screw hole diameter is 0.147" (3.7mm), diameter. Max mounting screw No. 6. Specifications Description: Single-pole fuse block for 14" x 1" fuses. Dimensions: See Dimensions illustrations. Construction: Bakelite with 12" (12.7mm) width base. Spring-bronze, bright tin-lead plated clips. Ratings: Volts: -- 250V Amps: -- 30A Mounting: Mounting screw hole diameter is 0.147" (3.7mm), counterbore 0.636" (8.0mm) diameter. Max mounting screw No. 6. Catalog Numbers Poles 1 2 3 4 5 6 7 8 10 12 *Base Length - in (mm) 2 (12.7) 1 18 (28.6) 1 34 (44.5) 2 38 (60.3) 3 (76.2) 3 58 (92.1) 4 14 (108.0) 4 78 (123.8) 6 18 (155.6) 7 38 (187.3) 1 *Small phenolic base, base width 1 38" (34.9mm) Catalog Numbers Catalog Numbers 4520 4393 Description Integral clip and straight solder terminals Spare fuse block Fuse Holders & Blocks Catalog Numbers 3828-1 3828-2 3828-3 3828-4 3828-5 3828-6 3828-7 3828-8 3828-10 3828-12 No. 4520 - Integral clip and straight solder terminals Dimensions - in (mm) Dimensions - in (mm) 1.88" (47.6mm) 1.94" (49.2mm) 0.63" .188" .598" (4.8mm) (15.9mm) (15.2mm) 0.19" 1.38" (4.8mm) (34.9mm) 1.38" (34.9mm) No. 4393 - Spare fuse block Dimensions - in (mm) 1.38" (34.9mm) 0.188" 0.598" (4.8mm) (15.2mm) Data Sheet: 2050 Data Sheet: 2051 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 289 Fuse Holders and Blocks Blocks for 1332" X 112" Fuses 3743 3835 Series 4421 and 4515 Specifications Specifications Description: Add-on fuse blocks for 13 32" X 1 12" (10.3 X 38.1mm) fuses. Single pole blocks lock into each other and can be added at any time. Each has a single end barrier. Dimensions: See Dimensions illustration. Ratings: Volts: -- 600Vac/dc Amps: -- 30A Agency Information: CE, UL Recognized Guide IZLT2, File E14853. Description: Multiple pole fuse blocks for 1332" X 1 12" (10.3 X 38.1mm) fuses. Dimensions: See Dimensions illustration. Ratings: Volts: -- 250Vac/dc Amps: -- 30A Agency Information: CE Catalog Numbers Catalog Numbers 3835-1 3835-2 3835-3 3835-4 3835-5 3835-6 3835-7 3835-8 3835-9 3835-10 3835-12 Poles 1 2 3 4 5 6 7 8 9 10 12 Base* Width In (mm) 27 32 (21.4) 1 1316 (46.0) 2 2532 (70.6) 3 34 (95.2) 4 2332 (119.9) 5 1116 (144.5) 6 2132 (169.0) 7 58 (193.7) 8 1932 (218.8) 9 916 (242.9) 11 12 (292.1) *Base length: 2 34" (69.9mm) 0.84" 1.29" Specifications Description: Single pole fuse blocks for 1332" X 1 12" (10.3 X 38.1mm) fuses. Dimensions: See Dimensions illustration. Ratings: Volts: -- 250Vac/dc (or less) Amps: -- 30A Agency Information: CE 2.5" (63.5mm) 0.897" 0.19" (22.78mm)(4.8mm) Dimensions 1.63" (41.3mm) 2.75" 0.500" (69.9mm) 4421--Solder Terminals 3742 2.56" 1.0" 1.125" 0.25" (25.4mm) (6.4mm) Base width 58" (15.9mm) 0.25" 2.56" (65.1mm) 3742--End Barrier Only 2.56" Note: Mounting screw hole diameter is 0.148" (3.7mm). Countersink, 0.313" (7.9mm). Max. mounting screw No. 6. 0.323" (65.1mm) (8.2mm) 0.897" 0.19" (22.78mm) (4.8mm) 0.25" 1.125" (6.4mm) (28.6mm) 0.78" (19.8mm) 4515--Screw Terminals 0.144" 1.34" (34.1mm) 3723--Block and end barrier marking strip. Length is 938" Base width 34" (19mm) Note: Mounting screw hole diameter is 0.147" (3.7mm). Countersink, 0.312" (7.9mm). Max. mounting screw No. 6. (23.8cm). Note: Mounting screw hole is 0.147" (3.7mm) dia. Counterbore, 0.636" (8mm) dia. Max. mounting screw No. 6. Data Sheet: 2104 290 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Holders and Blocks Rail Mount Fuse Blocks and Holders NDNF1-WH NDNLFD1-WH Specifications Specifications Description: Fuse holding rail mount terminal block. Circuit Jumper: JF1, 2 circuits Fuse Size: 1332" X 112"* (KTK, FNQ). Poles: 1 Wire Range: AWG #8-22 Cu. Ratings: Volts: -- 600V Amps: -- 30A Mounting Options: 35mm DIN rail, C-rail Fuse Pullers: * PF1 (standard) * neon or incandescent bulb Description: Rail mount fuse holder. Circuit Jumper: JF1, 2 circuits. Fuse Size: 14" X 114" (Cooper Bussmann AGC, MDL or equivalent). Poles: 1 Wire Range: AWG #8-22 Cu. Ratings: Volts: -- 600V Amps: -- 30A (NDND1 non-fused) -- 15A (NDNFD1, 600V/CSA, fused) -- 15A (NDNLFD1*fused, indicating) *LPF1 (lighted neon or incandescent bulb). Torque Rating: 18 lb-in Operating Temperature: 105C Agency Information: CSA File 15364 Catalog Numbers Catalog Color White Agency Information: CE, UL E62622; CSA LR15364. Mounting Options: 35mm DIN rail, C-rail Marking Tape: MT12-1-2 Torque Rating: 18 lb-in Operating Temperature: 105C Agency Information: CSA File 15364 Catalog Numbers Fuse Pullers (Optional): PF1 Lighted neon or incandescent lamp: Catalog Number Color Indicator Catalog NDNFD1-WH White NO NDNLFD1-WH White 90Vdc-600Vdc 115Vac-600Vac NDNLFD1-WH 24 White 24V Numbers Voltage LPF1-24 24 LPF1-120 120 LPF1-120-C 120 LPF1-220 220 LPF1-440 440 Fuse Holders & Blocks Number NDNF1-WH *WH24 - 24V White, WH-90Vdc-600Vdc, 115Vac-600Vac White For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 291 292 Power Distribution & Terminal Blocks Section Contents Page Selection table for SCCR PDBs & Power terminal blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294 Power diistribution blocks Series PDBFS enclosed, with high SCCR . . . . . . . . . . . . 295 Series PDB with high SCCR . . . . . . . . . . . . . . . . . . . . . 296 Power terminal blocks Series 163 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297-298 Series 11675 2- to 12-Pole quick-connect . . . . . . . . . . . 299 Series 11725 2- to 4-Pole quick-connect . . . . . . . . . . . . 299 Series 160, 162, 163 & 165 . . . . . . . . . . . . . . . . . . . . . . 299 Series 162, 163 & 165 power stud terminal blocks . . . 30 00 Series 160, 162, 163 & 165 power splicer blocks . . . . 300 Series 14002 Barrier terminal blocks . . . . . . . . . . . . . . 301 Series 14004 Dead front terminal block . . . . . . . . . . . . 301 Power Distribution & Terminal Blocks 293 Power Distribution & Terminal Blocks Selection Table for SCCR Power Distribution Blocks and Power Terminal Blocks Short-Circuit Current Rated Power Distribution Blocks Cooper Bussmann offers three distinctly different styles of short-circuit current rated power distribution blocks (PDBs) and power terminal blocks (PTBs) to match different application needs. The differences are whether the power distribution blocks are enclosed or not, and whether they are UL1953 Listed PDBs or UL1059 Recognized PTBs, which have different minimum spacing requirements. The table on this page can assist in the selection of the right series for your application requirements. Control Panels. Marking the SCCR on Industrial Control Panels (NEC(R) 409.110), Industrial Machinery Electrical Panels (NEC(R) 607.3(A)), and HVAC equipment (NEC(R) 440.4(B)) is now required by the National Electrical Code. PDBs or PTBs not marked with a SCCR, typically are the weakest link and may limit an assembly to no more than 10kA SCCR. The PDBFS and PDB Series have increased spacing required where used in feeder circuits in equipment listed to UL508A (UL1059 PTBs must be evaluated for proper spacings). Also, for building wiring systems, the PDBFS Series and PDB Series power distribution blocks can be used to meet the new 2008 NEC(R) requirements in section 376.56(B) for PDBs in wireways. Why these are important? Assembly short-circuit current ratings (SCCRs) are now required in the 2008 NEC(R) and UL 508A Listed Industrial Selection Table Description High Enclosed SCCR* Spacing** 1" Air 2" Surface Industrial Control Panels UL 508A Branch Circuit Industrial Control Panels UL 508A Feeder Circuit Catalog Page UL Series PDBFS 295 UL 1953 Listed Yes Yes Yes Yes Series PDB 296 UL 1953 Listed No*** Yes Yes Yes HVAC UL 1995 Wireways NEC(R) 376.56(B) (Requires UL 1953) Yes Yes Yes Yes Yes Yes w/optional cover IP20 finger-safe under specific conditions, see datasheet 1149. *When protected by proper fuse class with maximum ampere rating specified or less. ** See PDB Spacing Requirements for Equipment table below. ***Optional covers are available. Not IP20, but provide a safety benefit. ****No, except: Yes, if single pole units installed with proper spacings. PDB & PTB Minimum Spacing Requirements for Equipment UL Standard Spacing between Spacing between live parts of live parts and opposite polarity grounded parts or enclosure Through air Over surface @600V @600V @600V 508A Feeder Circuits 508A Branch Circuits 1995 HVAC 1 2 1 3 1 1 8 3 8 2 1 2 Series PDB 2 2 1 Note: Refer to Specific UL standards for complete spacing details. Series PDBFS Data Sheet: 1049 294 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Power Distribution & Terminal Blocks Series PDBFS of Power Distribution Blocks Electrical * 600Vac/dc (UL 1953), 690Vac/dc (IEC) * IP20 finger-safe under specific conditions * Short-circuit current ratings up to 200kA, see table * Ampacities up to 760 amps * Cu wire range 14 AWG to 500 kcmil or 2.5 to 240 mm2 Feature/Benefits * Enclosed, safer installation; IP20 finger-safe under specific conditions * High short-circuit current ratings up to 200kA: PDBs do not have to be the weak link in achieving high SCCR for an industrial control panel * Small footprint saves panel space * Listed to UL 1953 which has minimum spacing requirements at 600V of at least 1" through air and 2" over surface required for feeders in UL 508A Industrial Control Panels * For 2D CAD drawings visit www.cooperbussmann.com Mechanical * DIN rail or panel mount; PDBFS330 & PDBFS504 panel mount only * Captive termination screws; screws do not get misplaced * Wire ready: captive termination screws shipped backed out to save time on conductor installations * Sliding DIN rail latch for easy mounting * Single pole, gang mountable for multiple pole applications with interlocking dovetail accessory (optional) * Flammability, UL 94V0 * Tin-plated Al connectors suitable for Cu conductors * Elongated hole for panel mounting; easier mounting with greater flexibility in matching up with drilled panel holes * Part 2A1279: Interlocking dovetail pin accessory One pin interlocks two units, two pins to interlock three units * DIN rail end anchors required to prevent damage to block when torquing Agency/Standards * UL Listed 1953, Guide QPQS, File E256146 * CSA Certified, Class 6228-01, File 15364 * IEC 60947-7-1 * IEC 60529, IP20 (finger-safe) under specific wiring conditions Series PDBFS Terminal Copper Conductor Capability Line Load Configuration Electrical (All Single Pole) Openings per Pole Amps Wire Range Wire Range Line Load Line Load J T RK1 RK5 AWG or kcmil AWG or kcmil LPJ JJS JJN LPS-RK LPN-RK FRS-R FRN-R 2/0 to 8 200 200 100 60 200kA 4 to 12 200 175 200 200 175 200 100 100 100 60 60 60 200kA 100kA 50kA 350 to 6 400 400 200 100 200kA 4 to 8 4 6 to 14 400 200 175 600 600 200 400 200 175 600 600 200 200 100 100 400 400 100 100 30 30 200 200 30 200kA 50kA 100kA 200kA 50kA 50kA 350 600 600 400 200 200kA 300 to 4 600 800* 600 200 100kA 600 500 600 400 to 6 600 800* 800* 600 600 600 400 400 600 200 200kA 100kA 100kA PDBFS204 175A 2/0 to 8 AWG 70 to 10 mm2 2/0 to 8 AWG 70 to 10 mm2 2/0 to 8 PDBFS220 175A 2/0 to 8 AWG 70 to 10 mm2 4 to 14 AWG 25 to 2.5 mm2 2/0 to 8 PDBFS303 310A 350kcmil to 6 AWG 350kcmil to 6 AWG 185 to 16 mm2 185 to 16 mm2 350 to 6 PDBFS330 380A 500kcmil to 6 AWG 240 to 16 mm2 2 to 14 AWG 35 to 2.5 mm2 500 to 6 PDBFS377 570A 300kcmil to 4 AWG 150 to 12 mm2 4 to 14 AWG 25 to 2.5 mm2 PDBFS500 620A 350kcmil to 4 AWG 350kcmil to 4 AWG 185 to 12 mm2 185 to 12 mm2 PDBFS504 760A 500kcmil to 6 AWG 500kcmil to 6 AWG 240 to 16 mm2 240 to 16 mm2 14 2 to 6 300 250 to 4 350 300 to 4 500 400 to 6 8 to 14 SCCR (R) Ampacities 75C per NEC Table 310.16 and UL 508A Table 28.1 *Class L 800A (KRP-C 800_SP) or less fuses suitable for this particular SCCR case. ** Class G 60A (SC-60) or less or Class CC 30A (LP-CC-30, FNQ-R-30, KTK-R-30) or less are suitable for all SCCRs in this table. Data Sheet: 1049 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 295 Power Distribution & Terminal Blocks Catalog Number Short-Circuit Current Rating Data Conductors Max Fuse Class & Amp** Power Distribution & Terminal Blocks Series PDB of Power Distribution Blocks Electrical * 600Vac/dc (UL 1953) * Short-circuit current ratings up to 200kA, see table * Wire range 14 AWG to 350 kcmil Cu * Spacing between uninsulated opposite polarities or ground meets UL 1953 which requires at least 1" through air and 2" over surface * Ratings available with circuit breakers Feature/Benefits * High short-circuit current ratings up to 200kA. These PDBs do not have to be the weak link in achieving high SCCR for an industrial control panel * Listed to UL 1953 which has minimum spacing requirements at 600V of at least 1" through air and 2" over surface required for feeder in UL 508A Industrial Control Panels * For 2D CAD drawings visit www.cooperbussmann.com Agency/Standards * UL Listed 1953, Guide QPQS, File E256146 Mechanical * Panel mount * Flammability, UL 94V0 * Tin-plated Al connectors suitable for Cu conductors Optional covers Covers are ordered for each individual pole, i.e., three 1-pole covers for 3-pole block, see table A. Except PDB321 blocks have one cover for 1, 2 or 3 pole versions, see table B. Table A Table B Block Cover Block Cover PDB2XX-(pole): CPB162-1 PDB321-1 CPDB-1 PDB3XX-(pole): CPDB-1 PDB321-2 CPDB-2 PDB321-3 CPDB-3 Series PDB Terminal Copper Conductor Capability Line Load Configuration Catalog Number Openings per Pole Amps - Wire Range Wire Range Line Pole Load Short-Circuit Current Rating Data Conductors Max Fuse Class & Amp* Line Load J T RK1 RK5 AWG or kcmil AWG or kcmil LPJ JJS JJN LPS-RK LPN-RK FRS-R FRN-R 2/0 - 8 200 200 200 60 200kA 4 - 12 200 200 175 175 200 200 200 100 100 60 60 60 200kA 100kA 50kA 200 200 100 60 200kA 400 400 14 175 400 4-8 400 10 - 12 175 4-8 400 400 10 - 14 175 1/0 - 6 400 400 8 - 12 175 400 400 175 400 400 175 400 400 175 400 400 200 400 100 200 400 100 200 400 100 200 400 100 100 60 100 100 60 100 100 60 100 100 200kA 100kA 100kA 200kA 100kA 100kA 200kA 100kA 100kA 200kA 100kA 175 100 60 100kA PDB204-1 PDB204-3 175A 2/0 - 8 AWG 2/0 - 8 AWG 2/0 - 8 PDB220-1 PDB220-3 175A 2/0 - 8 AWG 4 - 14 AWG 2/0 - 8 PDB280-1 PDB280-3 175A 2/0 - 8 AWG 1/4-20 X 3/4 STUD 2/0 - 8 PDB321-1 PDB321-2 PDB321-3 175A PDB323-1 PDB323-3 2/0 - 8 AWG 4 - 14 AWG 2/0 - 8 310A 300kcmil - 4 AWG 4 - 12 AWG 300 - 4 PDB370-1 PDB370-3 310A 350kcmil - 4 AWG 4 - 14 AWG 350 - 4 PDB371-1 PDB371-3 310A 350kcmil - 4 AWG (6) 2 - 12 AWG (3) 1/0-12 350 - 4 14 Stud 4 -12 Ampacities 75C per NEC(R) Table 310.16 and UL508A Table 28.1 * Class G 60A (SC-60) or less or Class CC 30A (LP-CC-30, FNQ-R-30_SP, KTK-R-30) or less are suitable for all these SCCR in this table. Higher SCCR may be available, check data sheet 1149. Data Sheet: 1049 296 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa SCCR Power Distribution & Terminal Blocks Series 163 Power Terminal Blocks 163 Series Replaces Cooper Bussmann(R) 164 Series Specifications Description: Power terminal block. Dimensions: See Dimensions illustrations. Construction: Tin-plated aluminum connectors. Poles: 1- to 3-Poles, See Catalog Numbers table on the following page. Wire Range: See Catalog Numbers table on the following page. Ratings: Volts: -- 600Vac/dc Amps: -- See catalog Numbers table on the following page. SCCR:-- 10kA per UL 508A table SB4.1 Agency Information: CE, UL Recognized: Guide XCFR2, UL E221592, General Industrial Class per UL1059, CSA Certified: CSA LR15364 Flammability Rating: UL 94V0 Supplied with (4) #4 thread-cutting screws assembled as shown 4.14" Textured surface for marking Power Distribution & Terminal Blocks Dimensions 1-pole 1.96" 2-pole 3.58" CPDB-1 (single pole) CPDB-2 (two pole) CPDB-3 (three pole) 3-pole 5.20" 2.10" 3.72" 5.34" .31" 3.37" 4.00" 0.97" 1.62" 3.25" 3.32" Mtg. hole 0.21 x 0.41, c'bore 0.42 x 0.62 x 0.12 deep (See Following Page for Ratings) Data Sheet: 1049 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 297 Power Distribution & Terminal Blocks Series 163 Power Terminal Blocks Catalog Numbers Basic Catalog Numbers Wire Size (Poles) Lineside (Poles) Loadside Amps/ Pole 16301* 250kcmil-6 AWG Cu Only 250kcmil-6 AWG Cu Only 255 16303 350kcmil-6 AWG Cu-Al 350kcmil-6 AWG Cu-Al 310 16306 500kcmil-6 AWG Cu-Al 500kcmil-6 AWG Cu-Al 380 16321 2/0-14 AWG CU, 2/0-8Al (6)4-14 AWG Cu, 4-8 AWG Al 175 16323 350kcmil-6 AWG Cu-Al (6)4-14 AWG Cu, 4-12 AWG Al 310 16325 (2)2/0-14 AWG Cu, 2/0-8 AWG Al (6)4-14 AWG Cu, 4-8 AWG Al 350 16330 500kcmil-6 AWG Cu-Al (6) 2-14 AWG Cu, 2-12 AWG Al 380 16332 350kcmil-6 AWG Cu-Al (3) 2-14 AWG Cu, 2-8 AWG Al (2) 1/0-14 AWG Cu, 1/0-8 AWG Al 310 16335 500kcmil-6 AWG Cu-Al (3) 2-14 AWG Cu, 2-8 AWG Al (2) 1/0-14 AWG Cu, 1/0-8 AWG Al 380 16370 350kcmil-6 AWG Cu-Al (12)4-14 AWG Cu, 4-12 AWG Al 310 16371 350kcmil-6 AWG Cu-Al (6) 2-14 AWG Cu, 2-8 AWG Al (3) 1/0-14 AWG Cu, 1/0-8 AWG Al 310 16372 350kcmil-6 AWG Cu-Al (21) 10-14 AWG Cu, 10 AWG Al 310 16373 350kcmil-6 AWG Cu-Al (14) 10-14 AWG Cu, 10 AWG Al (3) 1/0-14 AWG Cu-Al 310 16375 600kcmil-2 AWG Cu-Al (12)4-14 AWG Cu, 4-12 AWG Al 420 16376 600kcmil-2 AWG Cu-Al (6) 2-14 AWG Cu, 2-8 AWG Al (3) 1/0-14 AWG Cu, 1/0-8 AWG Al 420 16377 (2)300kcmil-4 AWG Cu-Al (12)4-14 AWG Cu, 4-12 AWG Al 570 16378 500kcmil-6 AWG Cu-Al Stud Size (2) 1/4-20 x 1 380 16383 500kcmil-6 AWG Cu-Al Stud Size (1) 3/8-16 x 1 380 16390 3 8-16 x 118 Stud Size 250 16394 1 16395 3 8-16 x 118 Stud Size 3 2-13 x 1116 Stud Size 1 2-13 x 1116 Stud Size 400 8-16 x 1716 Stud Size (2) 14-20 x 916 Stud Size 310 *Copper connectors for use with copper wire only. Ordering Information 163 Series blocks are available in 1-, 2- or 3-poles. To order: Basic Catalog Number + Number of poles. Examples: 16301-1 = one-pole block 16301-3 = three-pole block Data Sheet: 1049 298 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Line/Load Power Distribution & Terminal Blocks Power Terminal Blocks Series 11675 Series 160, 162, 163 & 165 Specifications Description: Screw connection line side, (3) 0.250" quick-connect load side power terminal block. Poles: 2- to 12-poles. Wire Range: 8 - 14 AWG Cu. Ratings: Volts: -- 250Vac/dc Amps: -- Up to 40A SCCR:-- 10kA per UL 508A table SB4.1 Agency Information: CE, Guide XCFR2, UL E62622; CSA LR15364. Torque Rating: 9 lb-in max. Catalog Numbers Catalog Numbers 11675-2 11675-3 11675-4 11675-5 11675-6 11675-7 Poles 2 3 4 5 6 7 Catalog Numbers 11675-8 11675-9 11675-10 11675-11 11675-12 Poles 8 9 10 11 12 Specifications Description: Screw connection line side, (4) 0.250" quick-connect load side power terminal block. Poles: 2-, 3- or 4-poles. Wire Range: 2 - 14 AWG Cu/8 AWG Al. Ratings: Volts: -- 600Vac/dc Amps: -- Up to 70A SCCR:-- 10kA per UL 508A table SB4.1 Agency Information: CE, UL Guide XCFR2, E62622; CSA LR15364. Torque Rating: 45 lb-in max. Catalog Numbers Catalog Numbers 11725-2 11725-3 11725-4 Poles 2 3 4 Description: Power terminal blocks. Construction: Molded black thermoplastic. Wire Range: See Catalog Numbers table. Poles: Series 160: 2-, 3- or 4-poles Series 162, 163 and 165: 1-, 2- or 3-poles Ratings: Volts: -- 600Vac/dc Amps: -- Up to 1520A SCCR:-- 10kA per UL 508A table SB4.1 Agency Information: CE, Guide XCFR2, UL E221592 General Industrial Class per UL 1059; CSA Class 6228-01, File 53787. Flammability Rating: UL 94V0. Catalog Numbers Connector Load Material & Agency Connection Ampacity Information (6)#4-#14Cu, #4-#8Al 175A UL/CSA (6)#4-#14Cu, #4-#12Al 310A UL/CSA (4)#4-#14Cu, #4-#8Al 175A UL/CSA (6)#4-#14Cu, #4-#8Al 175A UL/CSA (6)#4-#14Cu, #4-#12Al 310A UL/CSA (6)#4-#14Cu, #4-#8Al 350A UL/CSA (6)#2-#14Cu, #2-#12Al 380A UL/CSA (3)#2-#14Cu, #2-#8Al 310A UL/CSA (2)1/0-#14Cu, 1/0-#8Al 16335 500kcmil-#6Cu/Al (3)#2-#14Cu, #2-#8Al 380A UL/CSA (2)1/0-#14Cu, 1/0-#8Al 16370 350kcmil-#6Cu/Al (12)#4-#14Cu, #4-#12Al 310A UL/CSA 16371 350kcmil-#6Cu/Al (6)#2-#14Cu, #2-#8Al 310A UL/CSA (3)1/0-#14Cu, 1/0-#8Al 16372 350kcmil-#6Cu/Al (21)#10-#14Cu, #10Al 310A UL/CSA 16373 350kcmil-#6Cu/Al (3)1/0-#14Cu/Al 310A UL/CSA (14)#10-#14Cu, #10Al 16375 600kcmil-#2Cu/Al (12)#4-#14Cu, #4-#12Al 420A UL/CSA 16376 600kcmil-#2Cu/Al (6)#2-#14Cu, #2-#8Al 420A UL/CSA (3)1/0-#14Cu, 1/0-#8Al 16377 (2)300kcmil-#4Cu/Al (12)#4-#14Cu, #4-#12Al 570A UL/CSA 16400 (4)500kcmil-#6Cu/Al (22)#2-#14Cu/Al 1520A UL/CSA 16528 (2)600kcmil-#2Cu/Al (4)3/0-#6Cu/Al 840A UL/CSA (4)#4-#14Cu/Al 16530 (2)500kcmil-#6Cu/Al (12)#4-#14Cu/Al 760A UL/CSA 16541 (1)500kcmil-#6Cu/Al (21)#6-#14Cu/Al 380A UL/CSA *160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165) have mounting holes within barriers. See Data Sheet for dimensional drawings. Catalog Line Numbers Connection 16021* 2/0-#14Cu, 2/0-#8Al 16023* 350kcmil-#6Cu/Al 16220 2/0-#14Cu, 2/0-#8Al 16321 2/0-#14Cu, 2/0-#8Al 16323 350kcmil-#6Cu/Al 16325 (2)2/0-#14Cu, 2/0-#8Al 16330 500kcmil-#6Cu/Al 16332 350kcmil-#6Cu/Al How To Order Catalog Number + # of Poles Example: 16021 - 3 (complete part number) Optional Covers: 160 162 163 165 Series: Series: Series: Series: CPB160 - (pole) CPB162 - (pole) CPDB- (pole) CPDB165 (1 for each pole) Data Sheets: 1117 (Series 160, 162, 165); 1148 (Series 163) For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 299 Power Distribution & Terminal Blocks Series 11725 Specifications Power Distribution & Terminal Blocks Power Terminal Blocks: Stud & Splicer Series 162, 163 & 165 Series 160, 162, 163 & 165 Specifications Description: Power stud terminal blocks. Construction: Molded black thermoplastic. Poles: 1-, 2- or 3-poles. Wire Range: See Catalog Numbers table. Ratings: Volts: -- 600Vac/dc Amps: -- Up to 760A SCCR:-- 10kA per UL 508A table SB4.1 Agency Information: CE, Guide XCFR2, UL E221592 General Industrial Class per UL 1059; CSA Class 6228-01, File 53787. Flammability Rating: UL 94V0. Specifications Description: Power splicer terminal blocks. Construction: Molded black thermoplastic. Wire Range: See Catalog Numbers table. Poles: Series 160: 2-, 3- or 4-poles Series 162, 163 and 165: 1-, 2- or 3-poles Ratings: Volts: -- 600Vac/dc Amps: -- Up to 620A SCCR:-- 10kA per UL 508A table SB4.1 Agency Information: CE, Guide XCFR2, UL E221592 General Industrial Class per UL 1059; CSA Class 6228-01, File 53787. Flammability Rating: UL 94V0. Stud Block Catalog Numbers Catalog Line Numbers Connection (Poles) Connector to Stud 16280 2/0-#14Cu-Al 16281 2/0-#14Cu-Al 16378 500kcmil-#6Cu-Al 16383 500kcmil-#6Cu-Al 16582 (2)500kcmil-#6Cu-Al Stud to Stud 1 16290 4-20 x 34 Stud 3 16390 8-16 x 118 Stud 1 16394 2-13 x 1116 Stud 3 16395 8-16 x 1716 Stud 3 16591 8-16 x 1716 Stud 1 16593 2-13 X 1 Stud Load Connection (Poles) Material & Ampacity Connector Agency Information 4-20 X 34 Stud 4-20 Tapped hole (2)14-20 x 1 Stud (1)38-16 x 1 Stud (2)38-16 x 158 Stud Al-175A Al-175A Al-380A Al-380A Al-760A UL UL UL UL UL -- -- CSA CSA CSA 4-20 x 34 Stud 8-16 x 118 Stud 1 2-13 x 1116 Stud (2)14-20 x 916 Stud (2)38-16 x 1716 Stud 1 2-13 X 1 Stud Cu-175A Cu-250A Cu-400A Cu-310A Cu-400A Cu-600A UL UL UL UL UL UL -- CSA CSA CSA CSA CSA 1 1 1 3 Nuts are not supplied with blocks How To Order Catalog Number + # of Poles Example: 16000 - 3 (complete part number) Series: Series: Series: Series: How To Order Catalog Number + # of Poles Example: 16000 - 3 (complete part number) Optional Covers: Optional Covers: 160 162 163 165 Catalog Numbers Connector Catalog Line Load Material & Agency Numbers Connection Connection Ampacity Information 16000* 2/0-#8Cu/Al 2/0-#8Cu/Al Al-175A UL 16003* 250kcmil-#6Cu Only 250kcmil-#6Cu Only Cu-255A UL 16005* 350kcmil-#6Cu/Al 350kcmil-#6Cu/Al Al-310A UL 16200 #2-#14Cu, #2-#8Al #2-#14Cu, #2-#8Al Al-115A UL 16201 1/0-#14Cu Only 1/0-#14Cu Only Cu-150A UL 16204 2/0-#8Cu/Al 2/0-#8Cu/Al Al-175A UL 16301 250kcmil-#6Cu Only 250kcmil-#6Cu Only Cu-255A UL/CSA 16303 350kcmil-#6Cu/Al 350kcmil-#6Cu/Al Al-310A UL/CSA 16306 500kcmil-#6Cu/Al 500kcmil-#6Cu/Al Al-380A UL/CSA 16500 (2)350kcmil-#4Cu/Al (2)350kcmil-#4Cu/Al Al-620A UL/CSA 16504 (2)500kcmil-#6Cu/Al (2)500kcmil-#6Cu/Al Al-760A UL/CSA *160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165) have mounting holes within barriers. See Data Sheet for dimensional drawings. CPB160 - (pole) CPB162 - (pole) CPDB - (pole) CPDB165 (1 for each pole) - new style CPB165 - (pole) - old style 160 Series: CPB160 - (pole) 162 Series: CPB162 - (pole) 163 Series: CPDB - (pole) For Short-circuit current rated stud power distribution blocks, go to the Series PDB and Series 162 & 163 with high SCCR. For Short-circuit current rated and/or finger-safe splicer blocks, go to the Series PDBFS, Series PDB or Series 162 & 163 with high SCCR. Data Sheets: 1117 (Series 162, 165); 1148 (Series 163) Data Sheets: 1117 (Series 160, 162, 165); 1148 (Series 163) 300 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Power Distribution & Terminal Blocks Power Terminal Blocks: Barrier & Dead Front Series 14002 Specifications Description: Barrier terminal block. Poles: 2- to 6-poles. Wire Range: 2 - 14 AWG Cu/8 AWG Al. Ratings: Volts: -- 600Vac/dc Amps: -- 115A SCCR:-- 10kA per UL 508A table SB4.1 Agency Information: CE, Guide XCFR2, UL E62622; CSA LR15364. Torque Ratings*: 2-3, 50 lb-in; 4-6, 45 lb-in; 8, 40 lb-in; 10-14, 35 lb-in. *Consult factory for torque ratings for CP and Q options. Marking: Marking strip optional, consult factory. Options For Load Side Connector CP: Sems pressure plate, rated 60A, 600V Q: Quick-Connect, rated 50A, 600V To order options, enter letter code in front of Catalog Number: i.e., CP14002-2. Catalog Numbers Poles 2 3 4 Catalog Numbers 14002-5 14002-6 Poles 5 6 Power Distribution & Terminal Blocks Catalog Numbers 14002-2 14002-3 14002-4 Series 14004 Specifications Description: Dead front terminal block. Poles: 2 to 12 poles. Wire Range: 4 - 14 AWG Cu/8 AWG Al. Ratings: Volts: -- 600Vac/dc Amps: -- 90A SCCR:-- 10kA per UL 508A table SB4.1 Agency Information: CE, Guide XCFR2, UL E62622; CSA LR15364. Marking: Marking strip optional, consult factory. Catalog Numbers Catalog Numbers 14004-2 14004-3 14004-4 14004-5 14004-6 14004-7 Poles 2 3 4 5 6 7 Catalog Numbers 14004-8 14004-9 14004-10 14004-11 14004-12 Poles 8 9 10 11 12 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 301 302 Connectors Section Contents Page Rail mount terminal blocks NDN Series 35mm DIN rail mount blocks . . . . . . . . 304-305 N512-BK 12-Pole block . . . . . . . . . . . . . . . . . . . . . . . . . 306 NFT2-WH 2-Pole block . . . . . . . . . . . . . . . . . . . . . . . . . 306 NFT3-_ _ 3-pole block . . . . . . . . . . . . . . . . . . . . . . . . . .306 NC3-WH 3-Pole block . . . . . . . . . . . . . . . . . . . . . . . . . . 307 NSE3-WH 3-Pole block . . . . . . . . . . . . . . . . . . . . . . . . . 307 NSS3-WH 3-Pole block . . . . . . . . . . . . . . . . . . . . . . . . . 307 Rail mount disconnect terminal blocks 15188 Series 3- and 4-Pole blocks . . . . . . . . . . . . . . . . 308 15288 Series 3-Pole block . . . . . . . . . . . . . . . . . . . . . . 308 Sectional terminal blocks PLU3-_ _ 3-Pole block . . . . . . . . . . . . . . . . . . . . . . . . . .309 PLU1-WH 1- to 3-Pole block . . . . . . . . . . . . . . . . . . . . . 309 PSU1-WH 1- to 3-Pole block . . . . . . . . . . . . . . . . . . . . . 309 KT3-WH 3-Pole block . . . . . . . . . . . . . . . . . . . . . . . . . . 310 KT4-WH 4-Pole block . . . . . . . . . . . . . . . . . . . . . . . . . . 310 PLK-3_ _ 3-Pole block . . . . . . . . . . . . . . . . . . . . . . . . . 310 Quick-connect terminal blocks NTQ23-WH 3-Pole block . . . . . . . . . . . . . . . . . . . . . . . . 311 BNQ21-WH 1-Pole block . . . . . . . . . . . . . . . . . . . . . . . . 311 BQQ41-WH 1-Pole block . . . . . . . . . . . . . . . . . . . . . . . . 311 Double row terminal blocks Series TB100 2- to 36-Pole blocks . . . . . . . . . . . . . 312-313 Series TB200 & TB200HB 2- to 30-Pole blocks . . . . 314-315 Series TB300 & TB345 2- to 24-Pole blocks . . . . . .298-299 2- to 12-Pole standard base . . . . . . . . . . . . . . . . . . . . . 322 2- to 12-Pole flat base . . . . . . . . . . . . . . . . . . . . . . . . . . 323 2- to 12-Pole raised base . . . . . . . . . . . . . . . . . . . . . . . .324 303 Connectors Marking options and covers for double row series . . . . . . . . . . . . . . . . . . . . . . . . . . 318 Top & bottom marking strips for double row terminal blocks . . . . . . . . . . . . . . . . . . . 319 Series TB400 2- to 12-Pole double row terminal blocks . . . . . . . . . . . . . . . . . . . . . . . . . 320 Series KU 2- to 12-Pole base mount double row terminal blocks . . . . . . . . . . . . . . . . . . . . . . 321 Series TS finger-safe terminal blocks Connectors Rail Mount Terminal Blocks NDN Series Specifications Description: High-density, snap-on 35mm DIN rail compatible rail mount terminal blocks. Construction: Unique, impact resistant, one-piece thermoplastic moldings. Heat treated stainless steel collars (to secure wires). Tin-plated copper alloy terminals. Zinc-plated steel screws. Circuits Per Foot: Up to 48 circuits per foot. Agency Information: CE, UL E62622; CSA LR15364. Flammability Rating: UL 94V2 NDNV4-__ __(color) NDN3-__ __(color) NDN63-__ __(color) Specifications Specifications Specifications Description: Rail mount terminal block. Rating: NDNV4 30A, 600V Center Spacing: 0.25" (6.35mm) Number of Poles: 4 Circuits Per Foot: 48 Circuit Jumper: JN4, 4 circuits Wire Range: AWG #10-22 CU Screw Size: #6-32 Mounting Options: 35mm DIN rail, C-rail Marking Tape: MTC6 Torque Rating: 18 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 15364. Catalog Numbers Catalog Description: Rail mount terminal block. Rating: 30A - field wiring: 40A factory wiring 600V Center Spacing: 0.300" (7.62mm) Number of Poles: 3 Circuits Per Foot: 38 Circuit Jumper: JNDN3, 2 circuits Wire Range: AWG #10-22 CU Screw Size: #6-32 Mounting Options: 35mm DIN rail, C-rail Marking Tape: MT12-1-2 Torque Rating: 18 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 15364. Description: Rail mount terminal block. Rating: 65A, 600V Center Spacing: 0.375" (9.52mm) Number of Poles: 3 Circuits Per Foot: 30 Circuit Jumper: JN3, 2 circuits Wire Range: AWG #6-18 CU Screw Size: #10-32 Mounting Options: 35mm DIN rail, C-rail Marking Tape: MT12-1-2 Torque Rating: 35 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 15364. Catalog Numbers Catalog Catalog Numbers Numbers Colors Numbers Colors Catalog NDNV4-WH White (Standard) Numbers Colors NDN63-WH White (Standard) NDNV4-BK Black NDN3-WH White (Standard) NDN63-BK Black NDNV4-YE Yellow NDN3-BK Black NDN63-YE Yellow NDN3-BL Blue NDN3-RE Red NDN3-YE Yellow 304 For more information, visit www.cooperbussmann.com Connectors Rail Mount Terminal Blocks NDN1-WH NDN111-__ __(color) Specifications Specifications Description: Rail mount terminal block. Rating: 90A, 600V Center Spacing: 0.635" (16.13mm) Number of Poles: 1 Circuits Per Foot: 18 Wire Range: AWG #2-18 Cu Screw Size: #1/4-28 Mounting Options: 35mm DIN rail, C-rail * Dove-tail option is available for mounting side-by-side. Order part no. NDN1A-WH Marking Tape: MT12-1-2 Torque Rating: 32 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 47235 Description: Rail mount terminal block. Rating: 90A, 600V Center Spacing: 0.635" (16.13mm) Number of Poles: 3 Circuits Per Foot: 18 Circuit Jumper: JN1, 2 circuits Wire Range: AWG #2-18 Cu Screw Size: #1/4-28 Mounting Options: 35mm DIN rail, C-rail, Base Mount * Dove-tail option is available for mounting side-by-side. Order part no. NDN111-A Marking Tape: MT12-1-2 Torque Rating: 32 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 47235 Catalog Numbers Catalog Numbers Catalog Catalog Number Color Numbers Colors NDN1-WH White NDN111-WH White (Standard) NDN111-BK Black NDN111-BL Blue NDN111-RE Red NDN111-YE Yellow NDN111A-WH White NDN111A-BK Black (Standard) NDN111A-YE Yellow Connectors NDN Series Terminal Block Accessories NDNA 35mm DIN Rail Aluminum NDNA 100 1 meter NDNA 200 2 meters NDNAS 35mm DIN Rail End Stop NFTA C-Rail Aluminum Lengths to 72" NRA C-Rail Low Profile No Flange Aluminum Lengths to 37-1/2" SOA72 72" Long Stand-Off Channel For C-Rail For more information, visit www.cooperbussmann.com MARKING TAPE See Series Specifications JUMPERS See Series Specifications 305 Connectors Rail Mount Terminal Blocks N512-BK NFT2-__ __(color) NFT3-__ __(color) Specifications Specifications Specifications Description: Rail mount terminal block. Rating: 5A, 600V; 20A, 300V Center Spacing: 0.197" (5.00mm) Number of Poles: 12 Circuits Per Foot: 60 Circuit Jumper: JN512, 12 circuits Wire Range: AWG #12-22 Cu Screw Size: #4-48 Mounting Options: C-rail, 15mm DIN rail Marking Tape: AT512 Torque Rating: 12 lb-in Operating Temperature: 105C Agency Information: CSA File 15364. Catalog Numbers Catalog Number Color N512-BK Black Dimensions - in (mm) 2.40 (60.96) Description: Rail mount terminal block. Rating: 40A, 600V; 55A Factory Wired Center Spacing: 0.281" (7.13mm) Number of Poles: 2 Circuits Per Foot: 38 Circuit Jumper: JN2, 2 circuits Wire Range: AWG #8-22 Cu Screw Size: #8-32 Mounting Options: C-rail Marking Tape: MT12-1-2 Torque Rating: 18 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 15364. Description: Rail mount terminal block. Rating: 40A, 600V 55A Factory Wired Center Spacing: 0.390" (9.91 mm) Number of Poles: 3 Circuits Per Foot: 28 Circuit Jumper: JN3, 2 circuits Wire Range: AWG #8-22 Cu Screw Size: #8-32 Mounting Options: C-rail Marking Tape: MT12-1-2 Torque Rating: 18 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 47235. Catalog Numbers Catalog Numbers Catalog Colors Numbers Colors NFT2-WH White NFT3-WH White (Standard) NFT2-BK Black NFT3-BK Black NFT2-BL Blue NFT3-BL Blue NFT2-RE Red NFT3-RE Red NFT3-YE Yellow Dimensions - in (mm) 0.60 (15.44) 0.07 (1.78) 1.68 (42.82) 1.09 (27.68) Dimensions - in (mm) 1.29 (32.94) 0.93 (23.80) 0.88 (22.35) 306 Catalog Numbers 0.36 (9.14) 1.23 (31.34) 1.18 (29.97) 1.23 (31.37) 0.65 (16.51) For more information, visit www.cooperbussmann.com 1.29 (32.94) Connectors Rail Mount Terminal Blocks NC3-__ __(color) NSE3-WH NSS3-__ __(color) Specifications Specifications Specifications Description: Rail mount terminal block. Rating: 175A, 600V Center Spacing: 1.06" (26.92mm) Number of Poles: 3 Circuits Per Foot: 11 Wire Range: 2/0-#14 Cu/Al Screw Size: 5/16-24 Mounting Options: C-rail, Base Mount Marking Tape: MT12-1-2 Torque Rating: 45 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 15364. Catalog Numbers Catalog Number Color NC3-WH White NC3-BK Black Dimensions - in (mm) Description: Rail mount terminal block. Rating: 30A, 600V Center Spacing: 0.385" (9.77mm) Number of Poles: 3 Circuits Per Foot: 28 Circuit Jumper: JNSS3, 2 circuits Wire Range: For use with wire crimped to ring terminal Screw Size: #6-32 Mounting Options: C-rail Marking Tape: MT12-1-2 Torque Rating: 12 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 15364. Catalog Numbers Number Color Catalog NSS3-WH White NSS3-BK Black Number Color NSE3-WH White Dimensions - in (mm) Catalog Numbers Catalog Dimensions - in (mm) 1.25 (31.75) 1.75 (44.45) Connectors 3.12 (79.38) Description: Rail mount terminal block. Rating: 115A, 600V Center Spacing: 1.06" (26.92mm) Number of Poles: 3 Circuits Per Foot: 11 Circuit Jumper: JNSE3, 2 circuits Wire Range: For use with wire crimped to ring terminal Screw Size: #1/4-28 Mounting Options: C-rail, Base Mount Marking Tape: MT12-1-2 Torque Rating: 32 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 15364. 1.24 (31.50) 0.250 x 0.190 mtg. slots 1.75 (44.45) 1.75 (44.45) 1.25 (31.75) 1.25 (31.75) 0.250 x 0.190" mtg. slots 1.53 (38.86) 3.12 (79.24) 1.32 (33.73) For more information, visit www.cooperbussmann.com 307 Connectors Rail Mount Disconnect Terminal Blocks 15188 Series 15288 Series Specifications Description: Disconnect terminal blocks for 35mm DIN rail mount. Rating: 30A, 600V* Center Spacing: 0.375" (9.52mm) Wire Range: #12-16 AGW Cu Screw Size: #6-32 zinc-plated philslot Number of Poles: 3- and 4-pole only Mounting: 35mm DIN Rail Optional End Stop NDNAS Jumpers: 2- through 4-pole available Materials: Molded Base: UL rated 94V-2 thermoplastic. Tin plated copper alloy contacts. Torque Rating: 12 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 47235. * 30A rating achieved with #10AWG wire crimped to ring terminal; 25A without. Catalog Number Build-A-Code Series Poles Wiring Specifications Description: Disconnect terminal blocks for 35mm DIN rail mount. Rating: 65A, 600V* Center Spacing: 0.54" (13.7mm) Wire Range: #6-16 AWG Screw Size: #8-32 zinc-plated philslot Number of Poles: 3-pole only Mounting: 35mm DIN Rail Optional Accessories: Optional End Stop NDNAS (order optional accessories seperately) Materials: Molded Base: UL rated 94V2 thermoplastic. Tin-plated copper alloy contacts. Torque Rating: 20 lb-in (30 lb-in for 8AWG bare wire) Operating Temperature: 105C (221F) Agency Information: UL File E62622 *CSA rating achieved with #6 AWG wire crimped to ring terminal 50A without. Options Catalog Number Build-A-Code 15188 - 3 to 4 Blank = In-line R = Reverse S = Locking Snap Series Poles Wiring Options** 3 Blank = In-line R = Reverse S = Snap ST = Screw Together SS = Solid DIN Rail Snap 15288 - Dimensions - in (mm) In-Line Wiring Direction **Options can be combined, e.g. STSS Dimensions - in (mm) Reverse Wiring Direction 3 Pole = 1.19 (30.22) 4 Pole = 1.56 (39.62) 1.94 (49.27) 1.70 (43.2) 2.30 (58.4) for ST option 0.54 (13.7) 1.94 (49.27) Reverse Wiring Direction 3 Pole = 1.19 (30.22) 4 Pole = 1.56 (39.62) 0.375 (9.52) 0.22 (5.58) In-Line Wiring Direction 1.70 (43.2) 1.94 (49.27) 1.94 (49.27) 308 For more information, visit www.cooperbussmann.com Connectors Sectional Terminal Blocks PLU3-_ _(color) PLU1-WH PSU1-WH Specifications Specifications Specifications Description: Depluggable rail mount sectional terminal block. Rating: 40A, 600V Center Spacing: 0.390" (9.91mm) Number of Poles: 3 Circuits Per Foot: 28 Circuit Jumper: JN3, 2 circuits Wire Range: AWG #8-22 Cu Screw Size: #8-32 Mounting Options: C-rail, Stackable Marking Tape: MT12-1-2 Torque Rating: 18 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 15364. Catalog Numbers Catalog Number Color PLU3-WH White (Standard) PLU3-BK Black PLU3-YE Yellow Description: Depluggable rail mount sectional terminal block. Rating: 70A, 600V Center Spacing: 0.625" (15.88mm) Number of Poles: 1-3 Part Numbers: * PLU1 (1-pole) * PLU11 (2-pole) * PLU111 (3-pole) Circuits Per Foot: 19 Circuit Jumper: JN1, 2 circuits Wire Range: AWG #4-18 Cu Screw Size: #1/4-28 Mounting Options: C-rail, Stackable Marking Tape: MT12-1-2 Torque Rating: 32 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 15364. Catalog Numbers Poles Color Catalog PLU1-WH 1 White Number Poles Color PLU11-WH 2 White PSU1-WH 1 White PLU111-WH 3 White PSU11-WH 2 White PSU111-WH 3 White 1.25 (31.75) Dimensions - in (mm) 1.85 (46.99) 1.48 (37.59) 1.93 (49.12) 1.48 (37.64) 0.625 (15.88) 1.79 (45.64) 1.85 (46.99) 2.44 (62.10) 1.25 (31.75) For more information, visit www.cooperbussmann.com 0.43 (11.10) 1.30 (33.00) 309 Connectors Dimensions - in (mm) 1.87 (47.49) 1.25 (31.75) Center Spacing: 0.625" (15.88 mm) Number of Poles: 1-3 Part Number: * PSU1 (1-pole) * PSU11 (2-pole) * PSU111 (3-pole) Circuits Per Foot: 19 Wire Range: For use with crimp on connectors only. Screw Size: #10-32 Mounting Options: C-rail, Stackable Marking Tape: MT12-1-2 Torque Rating: 24 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 15364 Number 1.25 (31.75) 0.59 (14.98) *45A rating achieved with ring terminal crimped to wire. Catalog Numbers Catalog Dimensions - in (mm) Description: Depluggable rail mount sectional terminal block. Rating: 45A*, 600V Connectors Sectional Terminal Blocks KT3-_ _(color) KT4-_ _(color) PLK3-WH Specifications Specifications Specifications Description: Depluggable rail mount sectional terminal block. Rating: 40A, 600V Center Spacing: 0.390" (9.91mm) Number of Poles: 3 Circuits Per Foot: 28 Circuit Jumper: JN3, 2 circuits Wire Range: AWG #8-22 Cu Screw Size: #8-32 Mounting Options: Base Mount, Stackable Marking Tape: MT12-1-2 Torque Rating: 18 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 15364 Catalog Numbers Catalog Number Color KT3-WH White KT3-BK Black KT3-RE Red Description: Depluggable rail mount sectional terminal block. Rating: 30A, 600V Center Spacing: 0.25" (6.35mm) Number of Poles: 4 Part Number: * KT4-WH-A * KT4-WH-B Note: When used in series must order A and B Circuits Per Foot: 48 Circuit Jumper: JN4, 4 circuits Wire Range: AWG #10-22 Cu Screw Size: #6-32 Mounting Options: Base Mount Mounting screws recommended every 12 circuits Marking Tape: MTC6 Torque Rating: 18 lb-in Operating Temperature: 105C Agency Information: UL File E62622, CSA File 15364 Catalog Numbers Description: Depluggable rail mount sectional terminal block. Rating: 40A, 600V Center Spacing: 0.39" (9.91mm) Number of Poles: 3 Circuits Per Foot: 28 Circuit Jumper: JN3, 2 circuits Wire Range: AWG #8-22 Cu Screw Size: #8-32 Mounting Options: Base Mount, Stackable; End Piece (Part No. KAD) is required for mounting. Mounting screws recommended every 15 circuits. Marking Tape: MT12-1-2 Torque Rating: 18 lb-in Operating Temperature: 105C Agency Information: UL File E62622 Catalog Numbers Catalog Number Color PLK3-WH White Catalog Dimensions - in (mm) 1.87 (47.63) Number Color KT4-WH White KT4-BK Black Dimensions - in (mm) 1.25 (31.75) 0.98 (24.99) 0.25 (6.35) Dimensions - in (mm) 0.37 (9.40) 1.46 (37.22) 0.56 (14.22) 1.22 (31.04) #8 screw clearance KAD end mtg. adapter 0.62 (15.88) 1.84 (46.86) 1.25 (31.75) 2.34 (59.51) 1.25 (31.75) 1.34 (34.04) 310 1.79 (45.52) 1.26 (32.23) For more information, visit www.cooperbussmann.com Connectors Quick-connect Terminal Blocks NTQ23-WH BNQ21-WH BQQ41-WH Specifications Specifications Specifications Description: Quick-connect terminal block. Rating: 40A, 600V Center Spacing: 0.390" (9.91mm) Number of Poles: 3 Circuits Per Foot: 28 Wire Range: AWG #8-22 Cu Screw Size: #8-32 Quick Connects: 0.250" x 0.031" Mounting Options: C-rail Marking Tape: MT12-1-2 Torque Rating: 18 lb-in Operating Temperature: 105C. Catalog Numbers Catalog Number Color NTQ23-WH White Description: Quickconnect terminal block. Rating: 40A, 600V Center Spacing: 0.437" (11.10mm) Number of Poles: 1 Circuits Per Foot: 24 Wire Range: AWG #8-22 Cu Screw Size: #8-32 Quick Connects: 0.250" x 0.031" Mounting Options: Base Mount Stackable; End Piece (Part No. BQE) is required for mounting. Mounting screws recommended every 8 circuits. Torque Rating: 18 lb-in Operating Temperature: 105C Screw Size: #8-32 Agency Information: UL File E62622, CSA File 15364 Description: Quick-connect terminal block. Rating: 30A, 600V Center Spacing: 0.437" (11.10mm) Number of Poles: 1 Circuits Per Foot: 24 Wire Range: For use with quickconnect terminals only. Quick Connects: 0.250" x 0.031" Mounting Options: Base Mount, Stackable; End Piece (Part No. BQE) is required for mounting. Mounting screws recommended every 8 circuits. Operating Temperature: 105C Agency Information: UL File E62622, CSA File 15364 Catalog Numbers Catalog Catalog Dimensions - in (mm) Number Color BNQ21-WH White Dimensions - in (mm) Number Color BQQ41-WH White Dimensions - in (mm) #8 mtg. screw #BQE (end mtg. adaptor) #8 mtg. screw Connectors #BQE (end mtg. adaptor) Catalog Numbers 1.25 (31.75) ( 1.25 (31.75) B B A A 0.56 (14.28) 0.56 (14.28) 1.31 (33.32) 1.25 (31.75) 1.47 (37.33) 1.47 (37.33) 1.41 (35.81) For more information, visit www.cooperbussmann.com 1.41 (35.81) 311 Connectors Double Row Terminal Blocks Series TB100 Specifications Description: Double row terminal blocks. Rating: 30A, 300V* Center Spacing: 0.375" or 3/8" (9.52mm) Wire Range: #14 - 22 AWG Cu Screw Size: #6-32 philslot screws Torque Rating: 9 lb-in. Distance Between Barriers: 0.30" (7.62mm) Mounting: #6 screws Operating Temperature: 130C (266F) max., -40C (-40F) min. Materials: Molded base: Black, UL rated 94V0 thermoplastic Terminal plating: Tin over brass; Screws: Zinc-plated steel Breakdown Voltage: 3600V Agency Information: UL File E62622/CSA File 47235; IEC Compliance; CE Certified TB100-08 TB100-04SP * Max rating shown; some options may be rated lower, consult Cooper Bussmann. Dimensions - in Poles 02 03 04 05 06 07 08 09 10 11 12 13 A 1.40 1.78 2.16 2.53 2.90 3.28 3.66 4.03 4.40 4.78 5.16 5.53 B 1.12 1.50 1.88 2.25 2.62 3.00 3.38 3.75 4.12 4.50 4.88 5.25 Poles 14 15 16 17 18 19 20 21 22 23 24 25 A 5.90 6.28 6.66 7.03 7.40 7.78 8.16 8.53 8.90 9.28 9.66 10.03 B 5.62 6.00 6.38 6.75 7.12 7.50 7.88 8.25 8.62 9.00 9.38 9.75 Poles 26 27 28 29 30 31 32 33 34 35 36 A 10.40 10.78 11.16 11.53 11.90 12.28 12.66 13.03 13.40 13.78 14.16 B 10.12 10.50 10.88 11.25 11.62 12.00 12.38 12.75 13.12 13.50 13.88 TB100- in (mm) A 0.14 (3.5) 0.14 (3.5) B 0.88 (22.3) 0.31 (7.9) 1" = 25.4mm. 0.17 dia. (4.3) 0.375 (9.5) 0.30 (7.6) 0.41 (10.4) 0.25 (6.3) Catalog Number Build-A-Code Series Poles Screw Options Marking/Cover Hardware Options 02 to 36 Blank = Steel philslot, zinc-plated 00 = Screws shipped bulk B = Brass philslot, nickel-plated BS = Brass Sems philslot, nickel-plated SP = Steel Sems philslot, zinc-plated P = Steel Sems (P-style) ST = Stainless steel, philslot STR = Stainless steel, phillips (recess) L1 to L6 Marking Strips (See page 318) Special Markings (See page 318) Covers (See page 318) QC1 to QC20 = Quick connects J101 = Flat slip-on jumper (2 position only) 0J2 = Over barrier jumpers 0J4 = Over barrier jumpers TB100 -- 312 For more information, visit www.cooperbussmann.com Connectors Double Row Terminal Blocks Screw Options B Brass Philslot Nickel-Plated BS Brass SEMS Philslot Nickel-Plated SP Steel SEMS Philslot Zinc-Plated P Steel (SEMS) (P-Style) ST Stainless Steel Philslot STR Stainless Steel Phillips (recess) Hardware Options Quick Connects - Assembled: Terminals 0.187" x 0.020". Maximum current rating 13 amps. For other orientations, contact Cooper Bussmann. QC1 QC8 QC14 QC2 QC3 QC4 QC5 QC6 QC9 QC10 QC11 QC12 QC13 QC15 QC16 QC17 QC18 QC19 QC7 QC20 Quick Connects - Bulk: minimum order per part number - 100 pieces. QC104 Flat - Flat Connectors QC101 Flat - none QC102 QC103 QC 45 - none QC 90 - none QC105 Flat - QC 45 QC106 QC107 QC108 QC109 Flat - QC 90QC 45 - QC 45 QC 45 - QC 90QC 90 - QC 90 Jumpers - Bulk: minimum order per part number - 100 pieces. Contact Cooper Bussmann for jumper assembly. J101 Flat slip-on OJ2 Slip-on over barrier OJ4 Closed over barrier For more information, visit www.cooperbussmann.com 313 Connectors Double Row Terminal Blocks Series TB200 & TB200HB Specifications Description: Double row terminal blocks. Ratings: Volts: -- 300V* (TB200) -- 600V* (TB200HB) Amps: -- 30A* Center Spacing: 0.437" or 7/16" (11.10mm) Wire Range: #12 - 22 AWG Cu Screw Size: #6-32 philslot screws Torque Rating: 9 lb-in. Distance Between Barriers: 0.353" (8.97mm) Mounting: #6 screws Operating Temperature: 130C (266F) max., -40C (-40F) min. Materials: Molded base: Black, UL rated 94V0 thermoplastic Terminal plating: Tin over brass; Screws: zinc-plated steel Breakdown Voltage: 4800V Agency Information: UL File E62622, CSA File 47235 & 15364; IEC Compliance; CE Certified TB200-10SP TB200HB-06 TB200 - in (mm) A 0.16 (4.0) 0.16 (4.0) B 1.12 (28.4) 0.44 (11.2) * Max rating shown; some options may be rated lower - consult factory. Dimensions - in Poles 02 03 04 05 06 07 08 09 10 11 A 1.63 2.07 2.51 2.94 3.38 3.82 4.25 4.69 5.13 5.57 B 1.31 1.75 2.18 2.62 3.06 3.50 3.93 4.37 4.81 5.25 Poles 12 13 14 15 16 17 18 19 20 21 A 6.00 6.44 6.87 7.31 7.75 8.19 8.62 9.06 9.50 9.94 B 5.68 6.12 6.56 7.00 7.43 7.87 8.31 8.75 9.18 9.62 Poles 22 23 24 25 26 27 28 29 30 A 10.37 10.81 11.25 11.68 12.12 12.56 13.00 13.44 13.87 B 10.06 10.50 10.93 11.37 11.81 12.25 12.68 13.12 13.56 0.17 dia. (4.3) 0.437 (11.1) 0.353 (8.9) 0.56 (14.2) .31 (7.8) TB200HB A 0.16 (4.0) 0.16 (4.0) B 1" = 25.4mm. 0.90 1.37 (22.8) (34.8) 0.44 (11.2) 0.17 dia. (4.3) 0.437 (11.1) 0.33 (8.4) 0.353 (8.9) 0.17 x 0.22 slots (4.3 x 5.6) 0.75 (19.0) Catalog Number Build-A-Code Series Poles Screw Options Marking/Cover Hardware Options 02 to 30 Blank = Steel philslot, zinc-plated 00 = Screws shipped bulk B = Brass philslot, nickel-plated BS = Brass Sems philslot, nickel-plated SP = Steel Sems philslot, zinc-plated P = Steel Sems (P-style) ST = Stainless steel, philslot SS = Stainless steel Sems, philslot STR = Stainless steel, phillips (recess) L1 to L6 Marking Strips (See page 318) Special Markings (See page 318) Covers (See page 318) QC1 to QC20 = Quick connects J201 = Flat slip-on jumper (2 position only) 0J3 = Over barrier jumpers 0J5 = Over barrier jumpers 0J7 = Over barrier jumpers -- TB 200 = Standard 200HB = High barrier 314 For more information, visit www.cooperbussmann.com Connectors Double Row Terminal Blocks Screw Options B Brass Philslot Nickel-Plated BS Brass SEMS Philslot Nickel-Plated SP Steel SEMS Philslot Zinc-Plated P Steel SEMS (P-Style) ST Stainless Steel Philslot SS Stainless Steel SEMS Philslot STR Stainless Steel Phillips (recess) Hardware Options Quick Connects - Assembled: Terminals 0.25" x 0.031". Maximum current rating 20 amps. For other orientations, contact Cooper Bussmann. QC1 QC2 QC3 QC4 QC5 QC6 QC8 QC9 QC11 QC10 QC12 QC13 QC14 QC15 QC16 QC17 QC18 QC19 QC7 QC20 Connectors Quick Connects - Bulk: minimum order per part no. - 100 pieces. QC201/J QC 45 - none QC204/J Flat - Flat QC202/J Flat - none QC205/J Flat - QC 45 QC203/J QC 90 - none QC206/J Flat - QC 90 QC207/J QC 45 - QC 45 QC208/J QC209/J QC 45 - QC 90 QC 90 - QC 90 Jumpers - Bulk: minimum. order per part no. - 100 pieces. Contact Cooper Bussmann for jumper assembly. J201/J Flat slip-on (not available on TB200HB) OJ3/J Slip-on over barrier for TB200HB OJ5/J Closed over barrier for TB200HB OJ7/J Closed over barrier for TB200 For more information, visit www.cooperbussmann.com 315 Connectors Double Row Terminal Blocks Series TB300 & TB345 Specifications Description: Double row terminal blocks. Ratings: Volts: -- 600V* Amps: -- 30A* (TB300) -- 45A (TB345) Center Spacing: 0.562" or 9/16" (14.28mm) Wire Range: #8 - 22 AWG Cu Screw Size: TB300 - #8-32 philslot screws TB345 - #10-32 philslot screws Torque Rating: #8 screws - 16 lb-in. ; #10 screws - 20 lb-in. Distance Between Barriers: 0.41" (10.5mm) Mounting: TB300 - #8 screws; TB345 - #10 screws Operating Temperature: 130C (266F) max., -40C (-40F) min. Material: Molded base: Black, UL rated 94V0 thermoplastic Terminal plating: Tin over brass; Screws: zinc-plated steel Breakdown Voltage: 7500V Agency Information: UL File E62622, CSA File 47235; IEC Compliance; CE Certified TB300-08 TB345-06SP TB300 & TB345 - in (mm) 8-32 binding head screw - TB 300 10-32 binding head screw - TB 345 A * Max rating shown; some options may be rated lower - consult Cooper Bussmann. 0.22 (5.6) Dimensions - in Poles 02 03 04 05 06 07 08 09 A 2.13 2.69 3.25 3.81 4.37 4.94 5.50 6.06 B 1.69 2.25 2.81 3.37 3.94 4.50 5.06 5.62 Poles 10 11 12 13 14 15 16 17 A 6.62 7.18 7.75 8.31 8.87 9.43 9.99 10.56 B 6.19 6.75 7.31 7.87 8.44 9.00 9.56 10.12 Poles 18 19 20 21 22 23 24 A 11.12 11.68 12.24 12.80 13.37 13.93 14.49 B 10.68 11.25 11.81 12.37 12.93 13.50 14.06 B 0.90 1.33 (22.8) (33.8) 0.50 (12.7) 0.56 (14.2) .21dia. (5.3) 0.56 (14.2) 0.21 x 0.25 slots (5.3 x 6.3) 0.412 (10.4) 1" = 25.4mm. 0.81 (20.5) 0.33 (8.4) Catalog Number Build-A-Code Series TB Poles 300 = 8-32 screw 02 to 24 345 = 10-32 screw 316 Screw Options Marking/Cover Hardware Options Blank = Steel philslot, zinc-plated 00 = Screws shipped bulk B = Brass philslot, nickel-plated BS = Brass Sems philslot, nickel-plated (TB300 only) SP = Steel Sems philslot, zinc-plated P = Steel Sems (P-style) ST = Stainless steel, philslot STR = Stainless steel, phillips (recess) L1 to L6 Marking Strips (pg 318) Special Markings (pg 318) Covers (pg 318) QC1 to QC20 = Quick connects (TB300 only) J301 = Flat slip-on jumper 0J6 = Over barrier jumper 0J11 = Over barrier jumper -- For more information, visit www.cooperbussmann.com Connectors Double Row Terminal Blocks Screw Options B Brass Philslot Nickel-Plated BS Brass SEMS Philslot Nickel-Plated SP Steel SEMS Philslot Zinc-Plated P Steel SEMS (P-Style) ST Stainless Steel Philslot STR Stainless Steel Phillips (recess) Hardware Options Quick Connects - Assembled: TB300 only. Terminals 0.25" x 0.031". Maximum current rating 20 amps. For other orientations, contact Cooper Bussmann. QC1 QC2 QC8 QC9 QC14 QC15 QC3 QC4 QC5 QC6 QC10 QC11 QC12 QC13 QC16 QC17 QC18 QC19 QC7 QC20 QC201 Flat - none QC202 QC 45 - none QC203 QC 90 - none QC204 Flat - Flat QC205 Flat - QC 45 QC206 Flat - QC 90 Connectors Quick Connects - Bulk: (*TB300 only) minimum order per part number. - 100 pieces. QC207 QC208 QC 45 - QC 45 QC 45 - QC 90 QC209 QC 90 - QC 90 Jumpers - Bulk: minimum order per part number - 100 pieces. Contact Cooper Bussmann for jumper assembly. J301 Flat slip-on(TB300 only) OJ6 Closed over barrier OJ11 Slip-on over barrier For more information, visit www.cooperbussmann.com 317 Connectors Marking Options and Covers for Double Row Series 3 2 1 L1 L2 L3 1 2 3 3 2 1 Note: Blocks marked on both sides require a different code for each side. Example Style L1 on one side of the block requires Style L2 on the other side to ensure common terminal marking. To order, add appropriate suffix (L1, L2, L3, L4, L5 and/or L6) to block catalog number in the proper sequence. 1 2 3 1 2 3 Standard markings are applied directly to the side(s) of a block. Standard color is white. Standard height is 0.125 inches (3.17mm). 1 2 3 Standard Marking L4 L5 L6 RED BLK BLU 3 4 134 G 134 20A OUT PUT 3AC GND M 300V MAX A MAS TER 5 K MB Special markings are available at an additional charge for preparation. Production charges for setup, handling and marking are the same as for standard marking. Drawing(s) must be submitted to ensure accuracy of part required. Consult Cooper Bussmann for price and delivery. INPUT Special Marking Note: Marking is not available on TB400 Series Covers Covers prevent personnel, screws and foreign items from contacting live terminals. Available in white or clear plastic. Two cover clips supplied with each cover. Cover width is 1.31 inches (33.3mm). All covers must be ordered separately. Consult Cooper Bussmann for special legends. Example: 10 position cover, white, TB100 Series, no legends = Catalog Number X12010. Catalog Number Build-A-Code Series Cover Strip Poles High Barrier Option Only Cover Clips - Bulk HB = High Barrier Part Number DD1-J - TB100 Series DD2-J - TB200 Series DD2HB-J -TB200HB Series DD3-J - TB300 Series X 120 119 220 219 320 319 - TB100/white TB100/clear TB200/TB200HB - white TB200/TB200HB - clear TB300 & TB345 - white TB300 & TB345 - clear 02 to 36 (TB100) 02 to 30 (TB200/TB200HB) 02 to 24 (TB300/TB345) Example: 10 position cover, white, TB100 Series, no legends . . . Part number is X12010. Note: Covers are not available on TB400 Series. 318 For more information, visit www.cooperbussmann.com Connectors Top & Bottom Marking Strips for Double Row Terminal Blocks Top Marker Strips Top mounting marker strips are available in white (opaque) plastic. Two cover clips are supplied with each marker strip. All top marker strips must be ordered separately. Consult factory for special legends. Example: 12 position cover, TB200, 0.032" x 0.312", with no legends = Catalog Number X20312. Example: 12 position cover, TB200HB, 0.06" x 0.50", with no legends = Catalog Number X23312HB. Catalog Number Build-A-Code Series Top Marker Strip Poles High Barrier Option Only 133 - TB100 (0.060 thk x 0.500 w) 103 - TB100 (0.032 thk x 0.312 w) 233 - TB200 (0.060 thk x 0.500 w) 233TB - TB200HB (0.060 thk x 0.500 w) 203 - TB200 (0.032 thk x 0.312 w) 203HB - TB200HB (0.032 thk x 0.312 w) 333 - TB300 & TB345 (0.060 thk x 0.500 w) 303 - TB300 & TB345 (0.032 thk x 0.380 w) Note: Marking Strips are not available on TB400 Series 02 to 36 (TB100) 02 to 30 (TB200/TB200HB) 02 to 24 (TB300/TB345) HB = High Barrier X Example: 12 position cover, TB200HB, 0.060 x 0.500, with no legends... Part No. is X23312HB. Bottom Marker Strips Bottom mounting marker strips are made of black PVC, 0.030" thick. Space is available to handle most marking situations. All marker strips must be ordered separately. To order, specify part number, required legends and (BF) bottom forward, (BR) bottom reverse, (TF) top forward, or (TR) top reverse. Consult factory for specials. Position for legends (one side, two sides) can be specified standard. Standard legend height is 0.125". Standard leg-ends are 0-99 and A-Z. Special legends are available on special order. Drawing(s) must be submitted to ensure accuracy of part required. Space for marking one side Space for marking two sides Dimensions (in) Dim. A B TB100 1.13 1.38 TB200 1.37 1.62 TB200HB TB300 1.62 1.58 1.81 1.81 TB345 1.58 1.81 TB400 N/A N/A Catalog Number Build-A-Code Series Bottom Marker Strip Poles High Barrier Option Only Orientation HB = High Barrier BF = Bottom forward BR = Bottom reverse TF = Top forward TR = Top reverse X 105 = TB100/marking one side 02 to 36 (TB100) 101 = TB100/marking both sides 02 to 30 (TB200/TB200HB) 205 = TB200/marking one side 02 to 24 (TB300/TB345) 201 = TB200/marking both sides 295 = TB200HB/marking one side 291 = TB200HB/marking both sides 305 = TB300 & TB345/marking one side 301 = TB300 & TB345/marking both sides Note: Marking Strips are not available on TB400 Series. For more information, visit www.cooperbussmann.com 319 Connectors Example: 13 position strip, TB100 with no legends, space for marking one side = Catalog Number X10513. Connectors Double Row Terminal Blocks Series TB400 Specifications Description: Double row terminal blocks. Ratings: Volts: -- 600V Amps: -- 75A Center Spacing: 0.687" or 11/16" (17.45mm) Wire Range: #6-14 AWG Cu Screw Size: #10-32 philslot screws Torque Rating: 20 lb-in. Distance Between Barriers: 0.56" (14.3mm) Mounting: #10 screws Operating Temperature: 130C (266F) max., -40C (-40F) min. Material: Molded base: Black, UL rated 94V0 thermoplastic Terminal plating: Tin over brass; Screws: zinc-plated steel Breakdown Voltage: 7500V Agency Information: UL File E62622, CSA File 47235; IEC Compliance; CE Certified Dimensions - in Poles 02 03 04 05 A 2.51 3.20 3.89 4.58 B 2.06 2.75 3.44 4.13 Poles 06 07 08 09 A 5.26 5.95 6.64 7.33 B 4.81 5.50 6.19 6.88 Poles 10 11 12 A 8.01 8.70 9.39 B 7.56 8.25 8.94 TB400-05 TB400 - in (mm) A B 0.22 (5.6) 0.15 dia. (3.8) 0.625 (15.9) 1" = 25.4mm. 1.12 (28.4) 0.22 dia. (5.6) 0.687 (17.4) 0.687 (17.4) 0.562 (14.3) 1.81 (46.0) Screw Options 0.76 (19.3) 0.46 (11.7) 1.34 (34.0) B Brass Philslot Nickel-Plated ST Stainless Steel Philslot STR Stainless Steel Phillips (recess) Hardware Options OJ14: Closed over barrier Catalog Number Build-A-Code Series Poles Screw Options Marking Hardware Options 02 to 12 Blank = Steel philslot, zinc-plated 00 = Screws shipped bulk B = Brass philslot, nickel-plated ST = Stainless steel, philslot STR = Stainless steel, phillips (recess) Not available 0J14 - Jumper over barrier TB400 - Contact factory for pole configuration. 320 For more information, visit www.cooperbussmann.com Connectors Base Mount Double Row Terminal Blocks Series KU Specifications Description: Base mount double row terminal blocks. Ratings: Volts: -- 600V Amps: -- 60A* Center Spacing: 0.625" (15.88mm) Number of Poles: 2- to 12-poles Wire Range: #6-22 AWG Cu Screw Size: #10-32 Torque Rating: 20 lb-in. Distance Between Barriers: 0.437" (11.09mm) Mounting: Base mount Material: Molded base: Black, UL rated 94V1 Nuclear Grade Noryl Terminal plating: Nickel over brass Operating Temperature: 105C max. Agency Information: UL File E62622, CSA File 47235 Series KU - in (mm) B 0.62 (15.9) * 60A rating achieved with #6 copper wire crimped to ring terminal. Dimensions - in KU A 2.50 3.12 3.75 4.37 5.00 5.62 6.25 6.87 7.50 8.12 8.75 B 1.62 2.25 2.87 3.50 4.12 4.75 5.37 6.00 6.62 7.25 7.87 KUX Only A 2.00 2.62 3.25 3.87 4.50 5.12 5.75 6.37 7.00 7.62 8.25 1.50 (38.1) 2.00 (50.8) #10 screw clearance 1.25 (31.8) 0.43 (11.1) 0.50 (12.7) Connectors Poles 02 03 04 05 06 07 08 09 10 11 12 1" = 25.4mm. A Catalog Number Build-A-Code Series Poles Screw Options Covers Marking Strip KU = Standard block KUH = Block KUX = Short block KUSC = Standard w/shorting strap & 4 shorting screws KURL = Standard w/removable link KUXSC = Short block w/shorting strap & 4 Shorting screws KUXRL = Short block w/removable link 02 to 12 00 = Screws shipped bulk W = Brass washer head, nickel-plated P = Steel screw w/pressure plate zinc-plated B = Brass washer head, no plating BP = Brass philslot, nickel-plated WC = Top cover & 2 end plates MT = Matte finish NU = Numbered 1 to 12, horizontal NUV = Numbered 1 to 12, vertical PT = Marker strip for cover Accessories MTMU## Molded Marking Tape Matte Finish NUM## Molded Marking Tape JU12 Jumper 12 Circuits NUE End Piece for NUC NUC## Cover For more information, visit www.cooperbussmann.com 321 Connectors Standard Base Terminal Blocks Series TS -- 8.0, 10.0, 12.0, 13.5mm centers Specifications Description: 8, 10, 12 and 13.5mm center, standard base terminal blocks. Construction: Mold to length polyamide type 6/6 housing, nickel-plated brass contacts and stainless steel wire protector. Ratings: Volts: -- 600V Amps: -- 20A (TS08) -- 30A (TS10) -- 35A (TS12) -- 50A (TS14) Wire Range: See Specifications Table Housing Material: Polyamide Type 6/6, 94V2 (white) Contact Material: Nickel-Plated Brass Wire Protector: Stainless Steel Screw Size: See Specifications Table Operating Temperature: 105C (221F) max., -30C (-22F) min. Torque Rating: See Specifications Table Agency Information: UL File E62622; CE Certified E C B D A D D A Dimensions - in (mm) Poles 2 3 4 5 6 7 8 9 10 11 12 TS08 0.622 0.937 1.252 1.567 1.882 2.232 2.512 2.827 3.142 3.457 3.772 (15.8) (23.8) (31.8) (39.8) (47.8) (55.8) (63.8) (71.8) (79.8) (87.8) (95.8) Specifications Torque in-lb 3.5 3.5 4.4 4.4 7.0 7.0 12.0 12.0 Position TS0801 TS0802 TS1001 TS1002 TS1201 TS1202 TS1401 TS1402 TS10 0.689 1.083 1.476 1.870 2.264 2.657 3.051 3.445 3.839 4.232 4.626 (17.5) (27.5) (37.5) (47.5) (57.5) (67.5) (77.5) (87.5) (97.5) (107.5) (117.5) Clamping Area (mm2) 4.0 1.5 6.0 2.5 10.0 6.0 16.0 10.0 TS12 0.815 1.287 1.760 2.232 2.705 3.177 3.650 4.122 4.594 5.067 5.539 (20.7) (32.7) (44.7) (56.7) (68.7) (80.7) (92.7) (104.7) (116.7) (128.7) (140.7) Wire Range AWG (Cu) 22-12 Sol./Str. 22-12 Sol./Str 22-10 Sol., 14-10 Str. 22-12 Sol./Str, 10 Sol. 22-10 Sol./Str. 22-10 Sol./Str. 20-8 Sol./Str. 20-8 Sol./Str. TS14 0.906 1.437 1.969 2.500 3.031 3.563 4.094 4.626 5.157 5.689 6.220 1.2mm STANDOFF (23.0) (36.5) (50.0) (63.5) (77.0) (90.5) (104.0) (117.5) (131.0) (144.5) (158.0) Dimensions Screw M2.6x5 M2.6x5 M3.0x6 M3.0x6 M3.5x7 M3.5x7 M4.0x9 M4.0x9 F F WIRE PROTECTOR - in (mm) B 0.67 (17.0) 0.67 (17.0) 0.80 (20.2) 0.80 (20.2) 0.94 (23.8) 0.94 (23.8) 1.01 (25.6) 1.01 (25.6) C 0.57 0.57 0.67 0.67 0.75 0.75 0.99 0.99 (14.5) (14.5) (17.0) (17.0) (19.0) (19.0) (25.2) (25.2) D 0.32 0.32 0.39 0.39 0.47 0.47 0.53 0.53 (8.0) (8.0) (10.0) (10.0) (12.0) (12.0) (13.5) (13.5) Catalog Number Build-A-Code Series Base Poles TS 08 10 12 14 322 = = = = 20A 30A 35A 50A 01 = Standard 02 = Standard w/ wire protector 02 to 12 For more information, visit www.cooperbussmann.com E 0.11 (2.9) 0.11 (2.9) 0.14 (3.6) 0.14 (3.6) 0.14 (3.9) 0.15 (3.9) 0.17 (4.4) 0.17 (4.4) F 0.11 (2.80.1) 0.11 (2.80.1) 0.13 (3.40.1) 0.13 (3.40.1) 0.15 (4.20.1) 0.15 (4.20.1) 0.19 (5.00.1) 0.19 (5.00.1) Connectors Flat Base Terminal Blocks Series TS -- 8.0, 10.0mm centers Specifications Description: 8 and 10mm center, flat base terminal blocks. Construction: Mold to length polyamide type 6/6 housing, nickel-plated brass contact and stainless steel wire protector. Ratings: Volts: -- 600V Amps: -- 20A (TS08) -- 30A (TS10) Wire Range: See Specification Table Housing Material: Polyamide Type 6/6, 94V2 (white) Contact Material: Nickel-Plated Brass Wire Protector: Stainless Steel Screw Size: See Specification Table Operating Temperature: 105C (221F) max., -30C (-22F) min. Torque Rating: See Specification Table Agency Information: UL File E62622; CE Certified E C A Dimensions - in (mm) Poles 2 3 4 5 6 7 8 9 10 11 12 TS08 0.622 0.937 1.252 1.567 1.882 2.232 2.512 2.827 3.142 3.457 3.772 TS10 0.689 1.083 1.476 1.870 2.264 2.657 3.051 3.445 3.839 4.232 4.626 (15.8) (23.8) (31.8) (39.8) (47.8) (55.8) (63.8) (71.8) (79.8) (87.8) (95.8) B D A (17.5) (27.5) (37.5) (47.5) (57.5) (67.5) (77.5) (87.5) (97.5) (107.5) (117.5) D D F F WIRE PROTECTOR Connectors Specifications Position TS0803 TS0804 TS1003 TS1004 Torque in-lb 3.5 3.5 4.4 4.4 Clamping Area (mm2) 4.0 1.5 6.0 2.5 Wire Range AWG (Cu) 22-12 Sol./Str. 22-12 Sol./Str 22-10 Sol., 14-10 Str. 22-12 Sol./Str., 10 Sol. Dimensions Screw M2.6x5 M2.6x5 M3.0x6 M3.0x6 - in (mm) B 0.64 (16.3) 0.64 (16.3) 0.80 (20.2) 0.80 (20.2) C 0.53 0.52 0.62 0.62 (13.3) (13.3) (15.8) (15.8) D 0.32 0.32 0.39 0.39 (8.0) (8.0) (10.0) (10.0) E 0.11 (2.9) 0.11 (2.9) 0.14 (3.6) 0.14 (3.6) F 0.11 (2.80.1) 0.11 (2.80.1) 0.13 (3.20.1) 0.13 (3.20.1) Catalog Number Build-A-Code Series Base Poles TS 08 = 20A 10 = 30A 03 = Flat 04 = Flat w/ wire protector 02 to 12 For more information, visit www.cooperbussmann.com 323 Connectors Raised Base Terminal Blocks Series TS - 8.0, 10.0mm centers Specifications Description: 8 and 10mm center, raised base terminal blocks. Construction: Mold to length polyamide type 6/6 housing, nickel-plated brass contacts and stainless steel wire protector. Ratings: Volts: -- 600V Amps: -- 20A (TS08) -- 30A (TS10) Wire Range: See Table Housing Material: Polyamide Type 6/6, 94V2 (white) Contact Material: Nickel-plated Brass Wire Protector: Stainless Steel Screw Size: See Table Operating Temperature: 105C (221F) max., -30C (-22F) min. Torque Rating: See Table Agency Information: UL File E62622; CE Certified Note: TS Series standard base pictured above. E C A Dimensions Poles 2 3 4 5 6 7 8 9 10 11 12 TS08 0.622 0.937 1.252 1.567 1.882 2.232 2.512 2.827 3.142 3.457 3.772 TS10 0.689 1.083 1.476 1.870 2.264 2.657 3.051 3.445 3.839 4.232 4.626 (15.8) (23.8) (31.8) (39.8) (47.8) (55.8) (63.8) (71.8) (79.8) (87.8) (95.8) (17.5) (27.5) (37.5) (47.5) (57.5) (67.5) (77.5) (87.5) (97.5) (107.5) (117.5) B D A D D 4.3mm F F WIRE PROTECTOR Specifications Position TS0805 TS0806 TS1005 TS1006 Torque in-lb 3.5 3.5 4.4 4.4 Clamping Area (mm2) 4.0 1.5 6.0 2.5 Wire Range AWG (Cu) 22-12 Sol./Str. 22-12 Sol./Str 22-10 Sol., 14-10 Str. 22-12 Sol./Str., 10 Sol. Dimensions Screw M2.6x5 M2.6x5 M3.0x6 M3.0x6 - in (mm) B 0.64 (16.30) 0.64 (16.30) 0.80 (20.20) 0.80 (20.20) C 0.67 0.67 0.79 0.79 (16.90) (16.90) (20.10) (20.10) D 0.32 0.32 0.39 0.39 Catalog Number Build-A-Code Series Base Poles 05 = Raised 06 = Raised w/ wire protector 02 to 12 TS 08 = 20A 10 = 30A 324 For more information, visit www.cooperbussmann.com (8.00) (8.00) (10.00) (10.00) E 0.11 (2.90) 0.11 (2.90) 0.14 (3.60) 0.14 (3.60) F 0.11 (2.80.1) 0.11 (2.80.1) 0.13 (3.20.1) 0.13 (3.20.1) Disconnect Switches Section Contents Page 325 Disconnect Switches Compact Circuit Protector (CCP) fused disconnect switches . . . . . . . . . . . . . . . . . . . .326-329 Fused, dead front disconnect switches . . . . . . . . . . .329 Fusible Disconnect Switch Overview . . . . . . . . . . . .330 30A Base & DIN rail mount fusible disconnect switches . . . . . . . . . . . . . . . . . . . .331-333 60-100A Base & DIN rail mount fusible disconnect switches . . . . . . . . . . . . . . . . . . . .334-336 200A Base & DIN rail mount fusible disconnect switches . . . . . . . . . . . . . . . . . . . .337-339 400-800A Base & DIN rail mount fusible disconnect switches . . . . . . . . . . . . . . . . . . . .340-343 30-400A Side operated fusible disconnect switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .344 30-100A Flange operated fusible disconnect switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .345 30-800A Cable operated fusible disconnect switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .346 UL/cULus & IEC Technical data for fusible disconnect switches . . . . . . . . . . . . . . . . . . . .347-349 Non-fusible Disconnect Switch Overview . . . . .350-351 16-100A Base & DIN rail mount non-fusible disconnect switches . . . . . . . . . . . . . . . . . . . .352-355 16-100A Door mounted non-fusible disconnect switches . . . . . . . . . . . . . . . . . . . .356-358 125A Non-fusible disconnect switches . . . . . . . .359-360 200A Non-fusible disconnect switches . . . . . . . .361-362 400A Non-fusible disconnect switches . . . . . . . .363-364 600-800A Non-fusible disconnect switches . . . .365-366 1200-1350A Non-fusible disconnect switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . .367-368 30-600A Side operated non-fused disconnects . . . .369 30-200A Flange operated non-fused disconnects . .370 30-200A Cable operated non-fused disconnects . . .371 UL/cULus & IEC Technical data for non-fusible disconnect switches . . . . . . . . . . . . . . . . . . . .372-377 30-800A Enclosed fusible disconnect switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . .378-380 16-3150A Enclosed fusible disconnect switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . .381-383 Technical data for enclosed non-fusible disconnect switches . . . . . . . . . . . . . . . . . . . .384-386 Disconnect Switches Compact Circuit Protector (CCP) Class CC, Midget & 10x38 Specifications Description: The revolutionary Cooper Bussmann(R) CCP is 1/3 the footprint of a circuit breaker. The level of protection provided by the CCP is up to three times the Short-Circuit Current Rating (SCCR) at full voltage than a molded case circuit breaker while providing disconnecting means. Ratings: * Box Lug Connection: 18-6AWG single or dual rated, solid or stranded - 75C or higher - Cu only, 4AWG single - 75C or higher - Cu only * Spade Terminal Connection: Max 30A suitable for use with #8-32UNC screw * Box Lug and Spade Terminal suitable for line, load or accessory connection * Torque: 18-10AWG 20 lb-in 8-4AWG 35 lb-in * Lock-out/tag-out: 4mm shank lock or standard pin-out devices * 35mm DIN Rail Mount * Local indication minimum operating voltage: 90Vac for AC version 12Vdc for DC version Up to 30A Features and Benefits: * Extremely compact design at 17.5mm wide per pole * High Short-Circuit Current Ratings up to 200kA * Disconnect Rated to provide means for load isolation * Full Voltage Rated 600Vac or 80Vdc * UL 98 disconnect rated for protection of branch circuits with Low-Peak(R) CUBEFuse and Class CC fuses. * Suitable for Global Installations, the units Complies with UL, CSA, and IEC standards accepting UL Class CC, Class CF Low-Peak CUBEFuse with Class J performance, Midget or IEC aM and gG fuses * Horsepower rated for protecting motor circuits with CUBEFuse and Class CC units. * Open Fuse Indication Local fuse indication lights* are standard Optional wired remote open fuse indication can be utilized to signal a PLC and open a contactor to de-energize all phases, if required. * IP20 finger-safe construction with 10AWG wire or larger * Built-in switch interlock capability prohibits removing the fuse under load * Padlockable handle for lock-out/tag-out procedures * Available in 1-, 2- and 3-pole versions *Circuit must be closed for indication light to illuminate Environmental Data: * RoHS Compliant: Yes * Storage and Operating Temperature: -20C to 75C** * CE Compliant: Yes **For fuse performance under or above 25C, consult fuse performance derating charts in the Cooper Bussmann publication titled Selecting Protective Devices (SPD) reorder #3002. Disconnect Switch Fuse Holder Knob Padlock Provision Fuse Indication Light Agency Information: * For Class CC fuse version UL 98 Listed, File E302370, Guide WHTY cULus to CSA Standard 22.2 No. 4-04, File 302370, Guide WHTY7 CE Compliant * For UL Midget and 10X38 IEC fuse version UL 508 Listed, File E161278, Guide 8R29 cULus Certified 22.2 No. 14-05 IEC 60947-3 AC23A IEC 60947-3 DC23A CE Compliant Data Sheet 1157 and the CCP Application Notes are available at www.cooperbussmann.com/ccp 326 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Circuit Marking Area Spade Connection Compression Lug Connection Disconnect Switches Class CC & 10x38 Up to 30A Technical Ratings Catalog Number Amp Poles Rating Voltage Rating Fuse Type Max. Fuse Ampacity SCCR CCP-1-30CC 1 30 600Vac Class CC 30A 200kA CCP-2-30CC 2 30 600Vac Class CC 30A 200kA CCP-3-30CC 3 30 600Vac Class CC 30A 200kA CCP-1-30M 1 30 240Vac* UL UL Midget 30A 400Vac* IEC 10x38 IEC 32A aM, 25A gG 240Vac* UL UL Midget 30A 400Vac* IEC 10x38 IEC 32A aM, 25A gG 240Vac* UL UL Midget 30A 400Vac* IEC 10x38 IEC Class CC (DC rated) 32A aM, 25A gG UL Midget 30A 10x38 IEC 32A aM, 25A gG CCP-2-30M 2 CCP-3-30M 3 30 30 CCP-1-DCC 1 30 80Vdc* CCP-1-DCM 1 30 80Vdc* Agency Approvals UL 98 Listed cULus 22.2 No. 4-04 UL 98 Listed cULus 22.2 No. 4-04 0.5Hp@120V UL 98 Listed cULus 22.2 No. 4-04 3Hp@240V 5Hp@480V 7.5Hp@600V Hp Ratings 2.0Hp@240V UL 508 Listed cULus 22.2 No. 14-05 120kA* IEC 60947-3 AC23A UL 508 Listed 10kA* cULus 22.2 No. 14-05 120kA* IEC 60947-3 AC23A UL 508 Listed 10kA* cULus 22.2 No. 14-05 120kA* IEC 60947-3 AC23A UL 98 Listed 20kA* CSA 22.2 No. 4-04 UL 508 Listed 10kA* cULus 22.2 No. 14-05 IEC 60947-3 DC23A 10kA* 30A -- -- -- -- -- *Rating may be lower depending on installed fuse. Refer to fuse data sheet. Disconnect Switches CCP-AUX CCP-PLC-IND (Includes spade terminals) Accessories Catalog Number Description Configuration Signal Output Minimum Circuit Voltage CCP-AUX Auxiliary Contacts NO+NC for Switch Status 1 per CCP 5A/240Vac - CCP-PLC-IND Wired Remote Fuse Indication for PLC Applications 1 per CCP 24Vdc 100Vac Agency Approvals UL 98 Recognized and cURus 22.2 No. 4-04, IEC 60947-5-1 AC15 UL 98 Recognized and cURus 22.2 No. 4-04 Data Sheet 1157 and the CCP Application Notes are available at www.cooperbussmann.com/ccp For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 327 Disconnect Switches Compact Circuit Protector (CCP) CUBEFuse(R) Up to 100A Features and Benefits: * Uses finger-safe Class CF Low-Peak(R) CUBEFuse(R) with Class J performance * Extremely compact design at 25.4mm (1 inch) wide per pole * High Short-Circuit Current Ratings at 200kA * Disconnect rated to provide means for load isolation * Full voltage rated at 600Vac * UL 98 Listed and suitable for branch circuit disconnect and branch circuit protection * 1-, 2- and 3-pole versions are horsepower rated Specifications Description: The revolutionary Cooper Bussmann(R) CCP is 1/3 the footprint of a circuit breaker. The level of protection provided by the CCP is up to three times the Short-Circuit Current Rating (SCCR) at full voltage than a molded case circuit breaker while providing disconnecting means. Ratings: * Box Lug Connection: 18-6 AWG single or dual rated, solid or stranded - 75C or higher - Cu only, 4 AWG single - 75C or higher - Cu only. * Spade Terminal Connection: Max. 30A suitable for use with #8-32 UNC screw. * Box Lug and Spade Terminal suitable for line, load or accessory connection. * Complies with UL and CSA * Open Fuse Indication: - Local fuse indication lights* are standard - Optional wired remote open fuse indication can be utilized to signal a PLC and open a contactor to de-energize all phases, if required * Additional open fuse indication can be provided by the CUBEFuse(R) * IP20 finger-safe construction with 10 AWG wire or larger * Built-in switch interlock capability prohibits removing the fuse under load * Padlockable handle for lockout/tagout procedures *Circuit must be closed for indication light to illuminate * Torque 0-60A: 18-10 AWG 20 lb-In 8-4 AWG 35 lb-In. * Torque 100A: 18-10 AWG Single 25 lb-In 8-2 AWG Single 35 lb-In 1 AWG Single 40 lb-In 6 AWG Dual 45 lb-In Lockout Provision Disconnect Switch Spade Connection * Lockout/tagout: 4mm shank lock or standard pin-out devices. * 35mm DIN rail mount. * Local indication minimum operating voltage: 90Vac/115Vdc. Agency Information: UL 98 Listed, File E302370, Guide WHTY cULus to CSA Standard 22.2 No. 4-04, File 302370, Guide WHTY7 CE Compliant Environmental Data: Circuit Marking Area Storage and operating temperature: -20C to 75C** **For fuse performance under or above 25C, consult fuse performance derating charts in the Cooper Bussmann publication titled Selecting Protective Devices (SPD) reorder #3002. Box Lug Connection Data Sheet 1157 and the CCP Application Notes are available at www.cooperbussmann.com/ccp 328 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Disconnect Switches Compact Circuit Protector (CCP) CUBEFuse(R) Up to 100A Technical Ratings Catalog Number Amp Voltage Poles Rating Rating 600Vac/ CCP-1-30CF 1 30 125Vdc 600Vac/ CCP-2-30CF 2 30 125Vdc CCP-3-30CF 3 30 CCP-1-60CF 1 60 CCP-2-60CF 2 60 600Vac/ 125Vdc 600Vac/ 125Vdc 600Vac/ 125Vdc Fuse Type Max. Fuse Ampacity SCCR Class CF CUBEFuse* 30A 200kA Class CF CUBEFuse* 30A 200kA Class CF CUBEFuse* 30A 200kA Class CF CUBEFuse* 60A 200kA Class CF CUBEFuse* 60A 200kA CCP-3-60CF 3 60 600Vac/ 125Vdc CCP-1-100CF 1 100 600Vac Class CF CUBEFuse* 100A 200kA CCP-2-100CF 2 100 600Vac Class CF CUBEFuse* 100A 200kA CCP-3-100CF 3 100 600Vac Class CF CUBEFuse* 100A 200kA Class CF CUBEFuse* 60A 200kA Agency Approvals UL 98 Listed cULus 22.2 No. 4-04 UL 98 Listed cULus 22.2 No. 4-04 UL 98 Listed cULus 22.2 No. 4-04 UL 98 Listed cULus 22.2 No. 4-04 UL 98 Listed cULus 22.2 No. 4-04 UL 98 Listed cULus 22.2 No. 4-04 UL 98 Listed cULus 22.2 No. 4-04 UL 98 Listed cULus 22.2 No. 4-04 UL 98 Listed cULus 22.2 No. 4-04 Hp Ratings 1.5Hp@120V 3.0Hp@240V 5Hp@240V 15Hp@480V 10Hp@600V 3.0Hp@120V 7.5Hp@240V 7.5Hp@240V 20Hp@480V 10Hp@600V 5Hp@120V 10Hp@240V 20Hp@240V 50Hp@480V 50Hp@600V *Class J performance. Fused, Dead Front Disconnect Switches 15149 Series Disconnect Switches Specifications Description: Fused, dead front disconnect switches Ratings: Volts: -- 600Vac Amps: -- 0-30A SCCR: -- 200kA RMS Sym. Dielectric SCCR: 2200V Motor Rating: 5Hp Poles: 2 to 3 Agency Information: UL Recognized, file E116716 for General Industrial installations. Guide WFXV2. CSA certified, file LR37129-6. Examined under the new proposed standard UL 1429 which imparts a stricter set of test conditions than the former program that combined the applicable portions for UL 512 (Fuse Holders) and UL 98 (Enclosed Switches). Features and Benefits * Fuse holders in the pull-out head eliminate possibility of electric shock while changing fuse. * Accepts Class J fuses Ordering Information To order, specify: 15149 + number of poles. Example: 15149-2 = 2-pole device. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 329 Disconnect Switches Overview for Fusible Disconnect Switches 330 Visit us on the web at www.cooperbussmann.com Disconnect Switches 30A Fusible Disconnect Switches Base & DIN Rail Mounted Disconnect Switches Visit us on the web at www.cooperbussmann.com 331 Disconnect Switches Handles & Shafts for 30A Fusible Disconnect Switches 332 Visit us on the web at www.cooperbussmann.com Disconnect Switches Accessories for 30A Fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 333 Disconnect Switches 60A - 100A for Fusible Disconnect Switches 334 Visit us on the web at www.cooperbussmann.com Disconnect Switches Accessories for 60A - 100A Fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 335 Disconnect Switches Accessories for 60A - 100A Fusible Disconnect Switches 336 Visit us on the web at www.cooperbussmann.com Disconnect Switches 200A Fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 337 Disconnect Switches Accessories for 200A Fusible Disconnect Switches 338 Visit us on the web at www.cooperbussmann.com Disconnect Switches Accessories for 200A Fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 339 Disconnect Switches 400A - 800A Fusible Disconnect Switches 340 Visit us on the web at www.cooperbussmann.com Disconnect Switches Accessories for 400A - 800A Fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 341 Disconnect Switches Accessories for 400A - 800A Fusible Disconnect Switches 342 Visit us on the web at www.cooperbussmann.com Disconnect Switches Accessories for 400A - 800A Fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 343 Disconnect Switches Side Operated Fusible Disconnect Switches for 30A - 400A 344 Visit us on the web at www.cooperbussmann.com Disconnect Switches Flange Operated Fusible Disconnect Switches for 30A - 100A Disconnect Switches Visit us on the web at www.cooperbussmann.com 345 Disconnect Switches Cable Operated Fusible Disconnect Switches for 30A - 800A 346 Visit us on the web at www.cooperbussmann.com Disconnect Switches UL & cULus Technical Data for Fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 347 Disconnect Switches IEC Technical Data for Fusible Disconnect Switches 348 Visit us on the web at www.cooperbussmann.com Disconnect Switches IEC Technical Data for Fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 349 Disconnect Switches Overview for Non-fusible Disconnect Switches 350 Visit us on the web at www.cooperbussmann.com Disconnect Switches Overview for Non-fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 351 Disconnect Switches 16A - 100A for Non-fusible Disconnect Switches 352 Visit us on the web at www.cooperbussmann.com Disconnect Switches Handles & Shafts for 16A - 100A Non-fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 353 Disconnect Switches Accessories for 16A - 100A Non-fusible Disconnect Switches 354 Visit us on the web at www.cooperbussmann.com Disconnect Switches Accessories for 16A - 100A Non-fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 355 Disconnect Switches 16A - 100A Non-fusible Disconnect Switches 356 Visit us on the web at www.cooperbussmann.com Disconnect Switches Accessories for 16 - 100A Non-fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 357 Disconnect Switches Accessories for 16A - 100A Non-fusible Disconnect Switches 358 Visit us on the web at www.cooperbussmann.com Disconnect Switches 125A Non-fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 359 Disconnect Switches Accessories for 125A Non-fusible Disconnect Switches 360 Visit us on the web at www.cooperbussmann.com Disconnect Switches 200A Non-fusible Disconnect Switches For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit CDNF200U03 + BDS210 + BDH60 + CDTL200 Non-Fusible 3 pole and 4 pole 200A Switch 200 AMP, 600V UL general purpose amp rating Maximum horsepower rating IEC AC21 Amp Rating 200V 208V 240V 480V 600V 200 250 60 60 75 250 200 CDNF200U03 200 250 60 60 75 250 200 CDNF200U04 Three phase Catalog number 3 pole BDH60, CDHXB86 4 pole Pistol handles - BDH59, 61 .24 x .24" ( UL/ NEMA type IEC type 1,3R,12 1,3R,12 IP65 IP65 1,3R,4,4X,12 1,3R,4,4X,12 IP65 IP65 Shafts - .24 x .24" ( Length inches/mm Marking Black Red/Yel 3.1/80 3.1/80 O/I & Off/On O/I & Off/On Yes Yes Yes Yes 0.30 0.30 BDH60 BDH61 Black Red/Yel 3.1/80 3.1/80 O/I & Off/On O/I & Off/On Yes Yes Yes Yes 0.30 0.30 CDHXB86 CDHXY86 Color Defeatable Padlockable Weight (lbs) Catalog number 6 x 6mm) Shaft length (inches/mm) 5.2/130 5.9/150 8.3/210 11.4/290 14.2/360 16.9/430 Mounting dept (inches) Weight (lbs) 4.3-6.5 5.0-7.2 7.4-9.6 10.5-12.7 13.3-15.5 16.0-18.2 Catalog number 0.08 0.09 0.13 0.18 0.23 0.27 BDS130 BDS150 BDS210 BDS290 BDS360 BDS430 Disconnect Switches BDS_ 6 x 6mm) Twisted shafts - rotates handle 45 .24 x .24" ( 6 x 6mm) Shaft length (inches/mm) 5.1/130 8.3/210 11.4/290 Mounting dept (inches) Weight (lbs) 4.29-6.85 7.44-10.0 10.59-13.15 Catalog number 0.08 0.13 0.18 BDST4 BDST25 BDST29 BDST_1 Direct mount handle - TEST-OFF-ON Description Color (lbs) Catalog number Up to 3 padlocks in OFF-position. Includes shaft and mechanism Black Red/Yel 0.22 0.22 Visit us on the web at www.cooperbussmann.com CDHTB20 CDHTY20 361 Disconnect Switches Accessories for 200A Non-fusible Disconnect Switches 362 Visit us on the web at www.cooperbussmann.com Disconnect Switches 400A Non-fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 363 Disconnect Switches 400A Non-fusible Disconnect Switches 364 Visit us on the web at www.cooperbussmann.com Disconnect Switches Accessories for 600A - 800A Non-fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 365 Disconnect Switches Accessories for 600A - 800A Non-fusible Disconnect Switches 366 Visit us on the web at www.cooperbussmann.com Disconnect Switches 1200A - 3150A Non-fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 367 Disconnect Switches Accessories for 1200A - 3150A Non-fusible Disconnect Switches 368 Visit us on the web at www.cooperbussmann.com Disconnect Switches Side Operated Non-fusible Disconnect Switches 30A - 600A Disconnect Switches Visit us on the web at www.cooperbussmann.com 369 Disconnect Switches Flange Operated Non-fusible Disconnect Switches 30A - 200A 370 Visit us on the web at www.cooperbussmann.com Disconnect Switches Cable Operated Non-fusible Disconnect Switches 30A - 200A Disconnect Switches Visit us on the web at www.cooperbussmann.com 371 Disconnect Switches UL & cULus Technical Data for Non-fusible Disconnect Switches 372 Visit us on the web at www.cooperbussmann.com Disconnect Switches UL & cULus Technical Data for Non-fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 373 Disconnect Switches IEC Technical Data for Non-fusible Disconnect Switches 374 Visit us on the web at www.cooperbussmann.com Disconnect Switches IEC Technical Data for Non-fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 375 Disconnect Switches IEC Technical Data for Non-fusible Disconnect Switches 376 Visit us on the web at www.cooperbussmann.com Disconnect Switches IEC Technical Data for Non-fusible Disconnect Switches CDNF200U03 - BDNF3150 IEC Catalog number 3 pole Rated voltage, Ue Rated conditional short-circuit current Max. allowed fuse size, type OFAA Max. allowed cut-off current, peak value CDNF200U03 CDNF400U03 BDNF600A V/V 500/690 500/690 500/690 BDNF800A 690 BDNF1200 690 BDNF1600 690 BDNF2000 690 BDNF3150 690 kA 100/80 100/80 45 45 45 50 50 A 350/355 500/500 100/50 8003 -- -- -- -- -- kA 40.5/40.5 615/59 62 -- -- -- -- -- 35 30 65 105 105 115 115 115 110 Rated short-circuit making capacity, prospective peak value, Icm kA Rated short time withstand current, RMS lcw 0.2s kA 15 28 38 RMS lcw 1.0s kA 8 15 17 100 505 100 505 505 110 505 110 505 415V A 2000 3200 5780 6400 6400 6400 6400 6400 500V A 2000 3200 4800 690V A 2000 3200 2800 6400 25006 6400 25006 6400 48006 6400 48007 48007 48V A 1000/2 -- -- -- -- -- -- -- 110V A 1000/2 -- -- -- -- -- -- 220V A 1000/2 1600/2 2000/2 1900/24 2600/24 2600/24 2600/24 -- 2600/24 440V A 1000/3 1600 2000 -- -- -- -- -- 750V A 1000/4 -- -- -- -- -- -- -- AC breaking capacity pf = 0.35 6400 DC breaking capacity/poles in series L/R = 15ms, 3 pole in series Capacitor ratings 400/415V Rated capacitor duty kVar -- -- 350 2 2 2 2 2 kA -- -- 500 2 2 2 2 2 Physical characteristics Electrical endurance at rated operational current, pf = 0.65 operation cycles Mechanical endurance Weight Dimension 3 pole operations 1000 1000 500 500 500 1008 1008 1008 20,000 16,000 10,000 10,000 10,000 6000 6000 6000 3 pole kg 1.2 2.2 6.2 16.3 17.5 37 37 37 4 pole kg 1.6 2.6 7.6 20.5 22.5 47 47 47 H mm Power loss per one pole 212 162 216 485 485 636 636 636 W mm 219 260 303 363 363 468 468 468 D mm 92.5 130 130 125 125 271 271 271 W Shaft size -- square 6.5 10 40 40 67 90 90 140 6x6 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 Nm 7 16 21 21 21 50 50 50 mm2 -- -- -- -- -- -- -- -- 8 x 25 10 x 30 12 x 40 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 CDAUX_ _ CDAUX_ _ BDAUX_ _ BDAUX_ _ BDAUX_ _ BDAUX_ _ BDAUX_ _ BDAUX_ _ VAC 690 690 690 690 690 690 690 690 A 16 16 10 10 10 10 10 10 A -- -- -- 8/-- 8/-- 8/-- 8/-- 8/-- --/1.1 mm Switch operating torque for rotary 3 pole switches Suitable conductor cross section Cu Auxiliary contacts Disconnect Switches Bolt size Ratings according to IEC 947-5-1 Rated voltage, Ui Thermal rated current, Ith AC12/DC12 Ie, A Ue = 2 3 5 6 7 8 120V 125V A -- -- -- --/1.1 --/1.1 --/1.1 --/1.1 240V A 6/-- 6/-- 6/-- 6/-- 6/-- 6/-- 6/-- 6/-- 250V A -- -- --/0.55 --/0.55 --/0.55 --/0.55 --/0.55 --/0.55 400V A 4/-- 4/-- 4/-- 4/-- 4/-- 4/-- 4/-- 4/-- 415V A -- -- 4/-- 4/-- 4/-- 4/-- 4/-- 4/-- 440V A -- -- --/0.31 --/0.31 --/0.31 --/0.31 --/0.31 --/0.31 480V A -- -- 3/-- 3/-- 3/-- 3/-- 3/-- 3/-- 500V A -- -- 3/0.27 3/0.27 3/0.27 3/0.27 3/0.27 3/0.27 600V A -- -- --/0.2 --/0.2 --/0.2 --/0.2 --/0.2 --/0.2 690V A 2/-- 2/-- 2/-- 2/-- 2/-- 2/-- 2/-- 2/-- Not available at time of printing, please consult factory. Size 4. Maximum distance between busbar support and switch terminal 70mm. pf 0.95. pf 0.65. IEC 947-3, utilization category B, infrequent operation. Load Figure 1 Visit us on the web at www.cooperbussmann.com 377 Disconnect Switches 30A - 800A Enclosed Fusible Disconnect Switches 378 Visit us on the web at www.cooperbussmann.com Disconnect Switches 30A - 800A Enclosed Fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 379 Disconnect Switches Approximate Diamensions for Enclosed Fusible Disconnect Switches 380 Visit us on the web at www.cooperbussmann.com Disconnect Switches 16A - 3150A Enclosed Non-fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 381 Disconnect Switches 16A - 3150A Enclosed Non-fusible Disconnect Switches 382 Visit us on the web at www.cooperbussmann.com Disconnect Switches Accessories for Enclosed Non-fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 383 Disconnect Switches Technical Data for Enclosed Non-fusible Disconnect Switches 384 Visit us on the web at www.cooperbussmann.com Disconnect Switches Approximate Dimensions for Enclosed Non-fusible Disconnect Switches Disconnect Switches Visit us on the web at www.cooperbussmann.com 385 Disconnect Switches Approximate Dimensions for Enclosed Non-fusible Disconnect Switches 386 Visit us on the web at www.cooperbussmann.com Telcom Protection Products Section Contents Page Telpower(R) compact fused disconnect switches . . . . .388 Telpower miniature fused disconnect switches . . . . 389 Fused disconnect switches for TPA fuses TP15914 4-Pole disconnect switch . . . . . . . . . . . . . . . .390 TP11590-4 4-Pole disconnect switch . . . . . . . . . . . . .391 TPA & TPA-B Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . .391 Fused disconnect switches for TPS fuses 15800 1-Pole fused disconnect switch . . . . . . . . . . . . .392 TPS Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .392 Fused disconnect switches TP158HC panel mount, rear access switch . . . . . . . . .393 15100 1-Pole switch for use with TPL fuses . . . . . . . .394 15200 1-Pole switch for use with TPL fuses . . . . . . . .394 TPHCS Telpower high-current switch . . . . . . . . . . . .395 TPL Telpower 70-600A: 170Vdc fuses . . . . . . . . . . . .396 TPN Telpower 1-600A: 170Vdc fuses . . . . . . . . . . . .397 70 Series Indicating fuses . . . . . . . . . . . . . . . . . . . .398 15087 Fuse holders . . . . . . . . . . . . . . . . . . . . . . . . . .398 HLS, HLT & PCT fuse holders . . . . . . . . . . . . . . . . . .399 GMT Fast acting fuses . . . . . . . . . . . . . . . . . . . . . . . .399 GMT-A Fast acting fuse . . . . . . . . . . . . . . . . . . . . . . .399 Telpower specialty fuses 7 Type Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400 11 Type Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400 24 & WER Type non-indicating, visible link fuses . . . .400 74 Type Fast acting fuses . . . . . . . . . . . . . . . . . . . . . . .400 75 Type Cylindrical fuses with leads . . . . . . . . . . . . . . .401 76 Type Cylindrical fuses with leads . . . . . . . . . . . . . . .401 80 Type visual indicating fuses . . . . . . . . . . . . . . . . . . .401 81 Type Fast acting, non-indicating fuses . . . . . . . . . . .401 Filtered terminal blocks F38 Series 2- to 8-Pole block . . . . . . . . . . . . . . . . . . . .402 Power feed through terminal blocks 387 Telcom Protection Products Series C7021 2- to 6-Pole block . . . . . . . . . . . . . . . . . . 403 Series C7024 1- to 12-Pole block . . . . . . . . . . . . . . . . .404 Telcom Protection Products Telpower(R) Compact Fused Disconnect Switches Catalog Numbers TPC & TPCDS Specifications Descriptions: -- TPC: Telpower(R) compact currentlimiting fuses. -- TPCDS: Telpower compact fused disconnect switch available in two disconnect switch profiles in addition to a variety of terminal styles. Recommended 0.75" center-to-center product spacing. Dimensions: See Data Sheet 5023. Ratings: Volts: -- 80Vdc Amps: -- 3-125A (See Catalog Numbers table for details) IR: -- 100kA Agency Information: CE, UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse pullout. Recognized to US and Canadian requirements under the component recognition program of Underwriters Laboratories Inc. Files E219046 and E56412. Flammability Ratings: Fuse UL 94V0, 170C RTI, Housing UL 94V0, 120C RTI. TPCS disconnect switch Catalog Amp Numbers Range TPCDS-BBE-1 3-125 TPCDS-BBE-2 3-125 TPCDS-BBE-3 3-125 TPCDS-BBM-1 3-125 TPCDS-BBM-2 3-125 TPCDS-BBM-3 3-125 TPCDS-BSE-1 3-125 TPCDS-BSE-2 3-125 TPCDS-BSE-3 3-125 TPCDS-BSM-1 3-125 TPCDS-BSM-2 3-125 TPCDS-BSM-3 3-125 TPCDS-SSE-1 3-125 TPCDS-SSE-2 3-125 TPCDS-SSE-3 3-125 TPCDS-SSM-1 3-125 TPCDS-SSM-2 3-125 TPCDS-SSM-3 3-125 TPCDS-D-BC1* 3-125 TPCDS-D-BC2* 3-125 TPCDS-D-CC1* 3-125 TPCDS-D-SEC1* 3-125 TPCDS-D-SEC2* 3-125 TPCDS-D-SMC1* 3-125 TPCDS-D-SMC2* 3-125 *Not investigated to Canadian Requirements. Features and Benefits * Highest interrupting rating (100kA) available and complete system coordination for dc circuit protection for compact footprint providing a superior protection solution for replacement of existing dc telecom circuit breakers * AmpColor IDTM System makes fuse replacement easy * Local and remote open fuse indication. Local alarm indication provided by LED on TPC fuse * Remote alarm terminal available in three positions common to dc circuit protection devices Typical Applications * Telecommunications DC power circuit protection * Replacement of DC telecom circuit breakers * Applications where venting of arc or molten metals and gases during opening would pose a problem to surrounding devices Data Sheet: 5023 388 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa TPC Current-Limiting Fuse Catalog Amp Numbers Rating TPC-3 3 TPC-4 4 TPC-5 5 TPC-6 6 TPC-7 7 TPC-8 8 TPC-10 10 TPC-12 12 TPC-15 15 TPC-20 20 TPC-25 25 TPC-30 30 TPC-40 40 TPC-50 50 TPC-60 60 TPC-75 75 TPC-90 90 TPC-100 100 TPC-125 125 Telcom Protection Products Telpower Miniature Fused Disconnect Switches Catalog Numbers TPM & TPMDS Specifications Description: -- TPM: Telpower miniature currentlimiting fuses. -- TPMDS: Telpower miniature fused disconnect switch. Dimensions: See Data Sheet 5022. Ratings: Volts: -- 80Vdc Amps: -- 3-30A IR: -- 20kA Agency Information: CE, UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse pullout. Recognized to US and Canadian requirements under the component recognition program of Underwriters Laboratories Inc. Files E219046 and E56412. Flammability Ratings: Fuse UL 94V0, 170C RTI; Switch UL 94V0, 140C RTI. Typical Applications * Telecommunications DC power circuit protection * Applications with restricted space, or mounting in 1 U panels Description Fuse Fuse Fuse Fuse Fuse Fuse Fuse Fuse Fuse Fuse Fuse Fuse Disconnect, English hardware Disconnect, Metric hardware Amp Rating 3 4 5 6 7 8 10 12 15 20 25 30 3-30 3-30 TPM Alarm Schematic NOTES: 1. The resistance, R, must be provided by the end-user to limit the alarm output current to a maximum of 20mA. The value, R, should be calculated using the system voltage value. * If remote alarm functionality is not required, the END-USER CIRCUITRY must still be supplied to provide a resistive path to the return for the local alarm to properly function. 2. The fuse is polarized to maintain proper orientation with the switch housing. The line and load terminals are identified on the switch housing. Data Sheet: 5022 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 389 Telcom Protection Products Features and Benefits * Smallest and most versatile fused disconnect switch available allowing for assembly into 1 U (1.75"/44.5mm) panel. Easy to connect; Load: 14" quick-connect or bolted connection with 10-32 (M5) captive nut, Line: 14" quickconnect or screw connection with clearance hole for #10 (M5) bolt. * AmpColor IDTM System makes fuse replacement easy * Switch design provides for easy panel mounting by single captive 4-40 (M3) nut and panel notch integral to switch footprint. * Complete system coordination capability with local and remote open fuse indication. Local alarm indication provided by LED on TPM fuse (maximum alarm circuit current: 20mA) Catalog Numbers TPM-3 TPM-4 TPM-5 TPM-6 TPM-7 TPM-8 TPM-10 TPM-12 TPM-15 TPM-20 TPM-25 TPM-30 TPMDS-E TPMDS-M Telcom Protection Products Fused Disconnect Switches for TPA Fuses Dimensions mm/in TP15914 Specifications Description: Modular 4-pole disconnect switch for TPA Series fuses -- 4-poles per module up to four modules ganged together. Features open fuse indication and fuse presence indication along with fuse orientation rejection feature. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 145Vdc Amps: -- 50A per pole Agency Information: CE, UL Recognized as a disconnect switch for interruption of load current by means of withdrawing the fuse carrier. UL Recognized as a component for telecommunication power distribution equipment (UL category QPQYZ), UL Recognized fuses for branch circuit protection, CSA component acceptance for the system. UL Recognized, Guide JFHR2, File E56412., CSA Certified, Class 1422-30, File 53787. Flammability Rating: UL 94V0, 140C. Features and Benefits * Totally enclosed module directly connects to busbar for reduced external wiring--per pole and easy installation with front access load and line connection standard-- double lug load connections 8 AWG wire * LED alarm signaling (LED current 30mA max) * Remote alarm with alarm test probe point to allow on-site checking of alarm circuitry * Bi-polar LED provides capability for both -48Vdc and +24Vdc applications 0.745 0.284 1.5 0.215 1.5 0.625 3.57 4.27 TOP 76.07 3.0 Accessories * Spare fuse holders: Catalog Numbers 5TPH and TPSFH-A Typical Applications * Telecommunications DC power circuit protection Catalog Numbers Catalog Numbers TP15914 TP15914-1 Hardware English Metric Data Sheet: 5011 390 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Telcom Protection Products Fused Disconnect Switches for TPA Fuses TPA & TPA-B TP15900-4 Specifications Description: 4-pole disconnect switch for use with Telpower fuses Type TPA & TPA-B. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 145Vdc (40A) -- 80Vdc (50A) Amps: -- 40A@145Vdc -- 50A@80Vdc Agency Information: CE, UL Recognized File E97649 as a disconnect switch for interruption of load current by means of withdrawing the fuse carrier. UL Recognized as a component for telecommunication power distribution equipment (UL category QPQY2). UL Recognized fuses for branch circuit protection. CSA Component Acceptance for the system. Flammability Rating: UL 94V0, 140C. Features and Benefits * Ease of installation - connection directly to busbar, reduces external wiring per pole. Rear accessibility for line and load terminations * LED alarm signaling (LED current 30mA max) * Local and remote open-fuse indication along with fuse orientation rejection feature and fuse presence indication * Alarm test probe point, to allow on-site checking of alarm circuitry Typical Applications * Telecommunications DC power circuit protection Catalog Numbers Catalog Numbers Description TP15900-4 4-Pole common disconnect switch TP15900-41 4-Pole common disconnect switch w/ Split Alarm, Split Line Specifications Description: DC power distribution indicating fuses. Dimensions: See Dimensions illustration. Ratings: Volts: -- 170Vdc TPA -- 65Vdc TPA-B Amps: -- 3-50A TPA -- 20-30A TPA-B IR: -- 100kA TPA -- 20kA TPA-B Agency Information: CE, UL Recognized, Guide JFHR2, File E56412, CSA Certified, Class 1422-30, File 53787. Features and Benefits * Indication pin provides for local and remote indication when used with Cooper Bussmann(R) TP15900-4 and TP15914 disconnect switches * Patented "orange ring" fuse orientation features assures correct fuse position * The UL Recognized ratings and current-limiting capability make this fuse ideal for cable protection on existing DC power distribution systems * A unique blue label is used on all Telpower fuses to designate their DC capability Typical Applications * Telecommunications DC power circuit protection Catalog Numbers (Amps) Catalog Numbers TPA-3 TPA-5 TPA-10 TPA-15 TPA-20 TPA-25 Amp Rating 3 5 10 15 20 25 Catalog Numbers TPA-30 TPA-40 TPA-50 TPA-B-20 TPA-B-25 TPA-B-30 Amp Rating 30 40 50 20 25 30 Dimensions - mm (in) Telcom Protection Products Dimensions - mm (in) Accessories * Spare fuse holders: 5 position holder; 5TPH; 6 position holder; TPSFH-AS * Use with fused disconnect switches TP15900-4, TP15914 Accessories * Spare fuse holders: Catalog Numbers 5TPH and TPSFH-AS. Data Sheet: 5001 Data Sheet: 5012 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 391 Telcom Protection Products Fused Disconnect Switches for TPS Fuses TPS 15800 Specifications Description: Fused disconnect switch for use only with the following fuses; Main: Telpower(R) TPS 3 to 70 Amp, Alarm: Cooper Bussmann GMT-A only (page 399). Recommend GMT-X Cover (page 399). Dimensions: See Dimensions illustration. Ratings: Volts: -- 60Vdc Amps: -- 3-70A SCCR: -- 100kA Agency Information: CE, UL Recognized, Guide QPQY2, File E97649. Flammability Rating: UL 94V0, 150C. Features and Benefits * Alarm output with wire wrap terminal or connection to 0.063" thick common alarm bus * Spare alarm and power fuse compartment * Mounting hardware included Typical Applications: * Telecommunications DC power circuit protection Features/Benefits * The UL Recognized ratings and current-limiting capability make this fuse ideal for cable protection on existing DC power distribution systems * A unique blue label is used on all Telpower fuses to designate their DC capability * Printed circuit board variations available Typical Applications * Telecommunications DC power circuit protection * Applications requiring printed circuit board mounting Catalog Numbers (Amps) TPS-1 TPS-1L TPS-2 TPS-2L TPS-3 TPS-3L TPS-5 TPS-5L TPS-6 Catalog Numbers Catalog Numbers 15800-R-200 15800-F-200 Specifications Description: DC power distribution non-indicating fuses specifically designed to meet the unique needs of DC power distribution systems. For use with Cooper Bussmann(R) fused disconnect switch 15800. Dimensions: See Dimensions illustration. Ratings: Volts: -- 170Vdc Amps: -- 1-70A. IR: -- 100kA Agency Information: CE, UL Recognized, Guide JFHR2, File E56412. Access Panel Mounting Rear Front Dimensions - in (mm) TPS-6L TPS-10 TPS-10L TPS-15 TPS-15L TPS-20 TPS-20L TPS-25 TPS-25L TPS-30 TPS-30L TPS-35 TPS-35L TPS-40 TPS-40L TPS-40V TPS-50 TPS-50L TPS-50V TPS-60 TPS-60L TPS-70 TPS-70L TPS-70LB Dimensions - in (mm) 72 lb-in Accessories * Spare fuse holder: TPSFH-AS, see page 414. Accessories * Spare fuse holders: Catalog Numbers TPSFH-AS (TPS fuses) and TPSFH-T (GMT fuses). Data Sheet: 5002 392 Data Sheet: 5009 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Telcom Protection Products Fused Disconnect Switches TP158HC Specifications Description: Panel mount, rear access high amp version of Cooper Bussmann(R) 15800 series fused disconnect switch for use only with the following fuses; Main: Telpower TPL-B 70-250 Amps, Alarm: Cooper Bussmann GMT-A. Dimensions: See Data Sheet 5021. Ratings: Volts: -- 80Vdc Amps: -- 70-250A SCCR: -- 100kA Agency Information: UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse pullout. Guide QPQY2, File E97649. Flammability Rating: UL 94V0, 150C. Application Notes * The line connection uses a 14-20 bolt (metric - M6X1) that threads into the line terminal. The line terminal is designed with a float of 0.02" ( 0.50mm) to allow for variation in the distance between the TP158HC mounting flange and the line busbar (see Dimensions). Equipment should be designed to eliminate any relative movement between the TP158HC mounting flange and the line busbar. * The alarm circuit is not intended for precharging of capacitive circuits. Alarm circuit current 1A maximum. Easy Fuse Replacement Features and Benefits * Similar profile, mounting method, and backplane configuration as 15800 Series. The TP158HC can be installed into existing 15800 Series panels using the space of two 15800 disconnects * Innovative new fuse pullout design eliminates need for tools to replace the Telpower type TPL-B fuse * Alarm output with wire wrap terminal or connection to 0.063 inch (1.6mm) thick common alarm bus * Hardware included: Load: washer, split lockwasher, and 5 16 - 18 nut (metric-M8 x 1.25) Typical Applications: * Telecommunications DC power circuit protection Catalog Numbers Hardware English Metric Telcom Protection Products Catalog Numbers TP158HC TP158HC-M Accessories * Spare fuse holders: TPSFH-LB (TPL-B fuses) and TPSFH-T (GMT fuses). Data Sheet: 5021 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 393 Telcom Protection Products Fused Disconnect Switches 15100 15200 Specifications Description: Fused disconnect system for use with Telpower fuses Type TPL. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 60Vdc Amps: -- 70-800A SCCR: -- 100kA Agency Information: CE, UL Recognized, Guide QPQY2, File E97649. Specifications Description: Fused disconnect system for use with Telpower fuses Type TPL. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 60Vdc Amps: -- 70-800A SCCR: -- 100kA Agency Information: CE, UL Recognized, Guide QPQY2, File E97649. Features and Benefits * Single-pole fusible disconnect switch for primary DC power distribution * Robust housing and terminal construction for demanding applications * Panel mounting * Easily connected to line or load bus Features and Benefits * Fusible disconnect transfer switch for primary DC power distribution * Robust housing and terminal construction for demanding applications * Panel mounting * Easily connected to line or load bus Typical Applications * Telecommunications DC power circuit protection Typical Applications * Telecommunications DC power circuit protection Catalog Numbers Catalog Numbers 15100-401 15100-601 Catalog Number For Use With TPL Series Fuses 70-400A 300-800A Catalog Number 15200-602 For Use With TPL Series Fuses 70-800A Dimensions - in (mm) Dimensions - in (mm) 6.75" (171.45mm) 3" 1" (76.2mm) (25.4mm) 3" 4" (76.2mm) (101.6mm) 5.86" (149.22mm) 8.69" (220.66mm) 0.27" (6.75mm) Dia. Hole with 0.5" (12.7mm) Dia. x 0.16" (3.97mm) Deep C'bore (4 Holes) 2" 0.88" 5.75" (50.8mm) (22.22mm) (146.05mm) #14 Thd. 1.88" (47.62mm) 7.25" (184.15mm) 3.63" (92.07mm) 0.31" (7.93mm) #18 Tap x 0.5" (12.7mm) Deep (4 Holes) 2.75" (69.85mm) 7.13" (181.10mm) 5" 6.75" (127.0mm) (171.45mm) 0.5" 11" 1.31" (33.33mm) 2.63" (279.4mm) 5.25" (304.8mm) (66.67mm) 12" (133.35mm) Data Sheet: 5003 394 Data Sheet: 5004 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa (12.7mm) Telcom Protection Products Telpower(R) High-current Switch Catalog Numbers - Switches (Pullout and Base) Amp Rating 70-250 70-250 70-250 70-250 70-250 70-250 300-800 300-800 300-800 300-800 300-800 300-800 Catalog Numbers - Components Catalog Numbers TPHCS250-P TPHCS800-P TPHCS-B-M TPHCS-B-E TPHCS-B-ML TPHCS-B-EL TPHCS-B-MAV TPHCS-B-EAV Description Rating/Hardware/Option Pullout only - 250A Pullout only - 800A Base only, Metric Base only, English Base only, Metric, LED Base only, English, LED Base only, Metric, Alarm Base only, English, Alarm Fuse Series TPL-B TPL-C or TPH -- -- -- -- -- -- Amp Rating 70-250 300-800 800 Max 800 Max 800 Max 800 Max 800 Max 800 Max Dimensions mm (in) O 7.62 (0.300) Type. 4 41.02 (1.615) L L L 66.4 (2.62) L L 25.9 (1.02) L 122.43 (4.820) L L 8.8 (0.34) L 22.2 (0.88) L L 12.7 (0.50) L 17.3 (0.68) L L L L L L 100.5 REF (3.96) 74.6 (2.94) 13.2 (0.52) L Threaded Insert, 4 Places M8x1.25 (-M Series) 5/16-18 (-E Series) Recommended Torque 15N * m (11 Ft-lb) 24.8 REF (0.98) L L L L L L L Telcom Protection Products L 105.2 (4.14) 139.7 (5.50) L See table for part number format L Typical Applications * Telecommunications DC power circuit protection * Compact design is ideal for today's high power, high-density cabinets Fuse Series TPL-B TPL-B TPL-B TPL-B TPL-B TPL-B TPL-C or TPH TPL-C or TPH TPL-C or TPH TPL-C or TPH TPL-C or TPH TPL-C or TPH L Features and Benefits * Innovative design eliminates need for tools to replace the Telpower(R) Type TPL-B, TPL-C or TPH fuse * Easy to install-captive fasteners allow for direct busbar mounting (bolts not included). Standard 14" male quickconnect terminal for effortless remote alarm connection. * Optional new electronic alarm eliminates need for parallel indicating fuses while providing local and remote openfuse indications (maximum remote alarm current: 20mA); Bipolar alarm: designed for both Central Office and Radio applications, Local LED alarm indication for ease-of-viewing. * Fuse presence window allows for easy viewing of installed fuse amp rating Hardware/ Option Metric English Metric, LED English, LED Metric, Alarm English, Alarm Metric English Metric, LED English, LED Metric, Alarm English, Alarm L Specifications Description: High current switch for use with Telpower fuses Type TPL-B, TPL-C and TPH. Available as complete switch or pullout. TPHCS800-MAV (shown) Base may be purchased separately. Dimensions: See Dimensions illustrations. Construction: Ratings: Volts: -- 80Vdc Amps: -- 70-800A SCCR: -- 100kA Agency Information: UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse carrier. UL Recognized to meet the requirements for Canadian Standards. Catalog Numbers TPHCS250-M TPHCS250-E TPHCS250-ML TPHCS250-EL TPHCS250-MAV TPHCS250-EAV TPHCS800-M TPHCS800-E TPHCS800-ML TPHCS800-EL TPHCS800-MAV TPHCS800-EAV L TPHCS Tin-Plated Copper Terminals L L 61.47 (2.420) L L 39.2 REF (1.54) L 16.76 (0.660) NOTES: 1. TPHCS250 and TPHCS800 pullouts and bases are the same with exception to the type of fuse, TPL-B, TPL-C or TPH the pullout will carry. 2. Plastic rated UL 94V0, 140C RTI. Data Sheet: 5020 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 395 Telcom Protection Products Telpower(R) 70-600A: 170Vdc Fuses TPL Dimensions - in (mm) Specifications Description: DC power distribution fuses for use with Telpower 15100, 15200, TP158HC and TPHCS disconnect systems. For replacement of Cooper Bussmann UBO fuses a TPL-TA adapter kit is necessary. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 170Vdc Amps: -- 70-800A IR: -- 100kA Agency Information: CE, UL Recognized Guide JFHR2, File E56412 Bellcore. Features and Benefits * Current-limiting capability designed for DC power distribution systems * Recognized branch circuit protection * Complete system coordination capability * Energy savings with low watts loss, low operating temperatures, and minimum I2t levels 2.66" (67.5mm) 2.19" (55.6mm) 1.91" (48.4mm) 1.0" 1.16" (25.4mm) (29.4mm) BUSS 0.75" (19.1mm) TPL-BL 0.33" 0.19" (8.3mm) (4.8mm) TPL-BA, TPL-BD, TPL-BF, TPL-BH, TPL-BK, and TPL-BL 3.50" (88.9mm) 2.44" (61.9mm) 1.50" 1.25" (38.1mm) (31.8mm) BUSS 1.00" (25.4mm) TPL-CZ 0.41" (10.3mm) TPL-CN, TPL-CR, TPL-CV, and TPL-CZ Typical Applications * Telecommunications power circuit protection Catalog Numbers Catalog Numbers Amp Rating TPL-BA 70 TPL-BB 80 TPL-BC 90 TPL-BD 100 TPL-BE 125 TPL-BF 150 TPL-BG 175 TPL-BH 200 TPL-BK 225 TPL-BL 250 TPL-CN 300 TPL-CO 350 TPL-CR 400 TPL-CU 450 TPL-CV 500 TPL-CZ 600 TPL-CZH 800 Accessories * Spare fuse holders: TPSFH-LB (for TPL-B fuses) TPSFH-LC (for TPL-C fuses) Data Sheet: 5005 396 0.25" (6.4mm) For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Telcom Protection Products Telpower(R) 1-600A, 170Vdc Fuses TPN Dimensions - in (mm) Specifications Description: Currentlimiting DC power distribution fuses. The TPN fuse series is dimensionally similar to Class R fuses making it easy to use standard Class R fuse blocks. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 170Vdc Amps: -- 1-600A IR: -- 100kA Agency Information: UL Recognized, Guide JFHR2, File E56412. Features/Benefits * Current-limiting capability designed for DC power distribution systems * Recognized branch circuit protection * Complete system coordination capability * Energy savings with low watts loss, low operating temperatures, and minimum I2t levels Typical Applications * Telecommunications power circuit protection Catalog Numbers (Amps) TPN-1 TPN-3 TPN-5 TPN-6 TPN-10 TPN-15 TPN-20 TPN-25 TPN-30 TPN-35 TPN-40 TPN-45 TPN-50 TPN-60 TPN-70 TPN-80 TPN-90 TPN-100 TPN-110 TPN-125 TPN-150 TPN-175 TPN-200 TPN-225 TPN-250 TPN-300 TPN-350 TPN-400 TPN-450 TPN-500 TPN-600 0.56" (14.3mm) 2" (50.8mm) 1A to 30A 0.81" (20.6mm) 3" (76.2mm) 35A to 60A 5.88" (149.2mm) 1.00" (25.4mm) 70A to 100A 7.13" (181.0mm) 1.50" (38.1mm) 110A to 200A 8.63" (219.1mm) 2.00" (50.8mm) 225A to 400A 10.38" (263.5mm) 2.50" (63.5mm) 450A to 600A Accessories * Spare fuse holders:TPSFH-N30 (for TPN 1-30) TPSFH-N60 (for TPN 35-60) Recommended Class R Fuse Blocks Poles 1 2 3 1 2 3 1 2 3 1 3 1 3 1 3 Catalog Number R25030-1CR R25030-2CR R25030-3CR R25060-1CR R25060-2CR R25060-3CR R25100-1CR R25100-2CR R25100-3CR R25200-1CR R25200-3CR R25400-1CR R25400-3CR R25600-1CR R25600-3CR Telcom Protection Products Amps 1-30 1-30 1-30 35-60 35-60 35-60 70-100 70-100 70-100 110-200 110-200 225-400 225-400 450-600 450-600 Data Sheet: 5006 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 397 Telcom Protection Products Indicating Fuses and Holders 70 Series Fuses 15087 Fuse Holder Specifications Description: Indicating type fuse. Ratings: Volts: -- 125Vac/300Vdc Amps: -- 110-10A IR: -- 1kA @ 300Vdc Agency Information: CE, UL Recognized, Guide JDYX2, File E19180 Bellcore. Catalog Numbers Catalog Amp Numbers Rating 1 70P-110A* 10 15 70R-15100A* 100 18 70E-18100A* 100 2 70X-210A 10 1 70F-14A* 4 1 1 70K- 4A* 4 1 1 70G- 2A* 2 3 3 70H- 4A* 4 70I-1A 1 1 1 70A-1 3A* 1 3 70B-2A* 2 70C-3A* 3 70J-312A 312 70D-5A* 5 70L-6A 6 70M-8A 8 70N-10A 10 GKB-10A 10 72A Plastic CaseDummy 72B Blister PackDummy Color Code Gray/Wh Red/Wh Yellow Black Violet Violet/Wh Red Brown Pink White Orange Blue Black/Wh Grn/Blk Grn/Wh Brown/Wh Violet/Yel Violet/Yel -- -- Lucent Comcode Ref. No. 100203413 101384550 100203363 -- 100203371 100203405 100203389 100203397 -- 100203322 100203330 100203348 -- 100203355 -- -- -- -- 100203421 103757977 Specifications Description: Fuse holder for 70 Series fuses. Ratings: Volts: -- 300Vdc Amps: -- 12A Agency Information: CE, UL Recognized, Guide IZLT2, File E14853. Flammability Rating: UL 94V0. Code/ List No. KS23751-L10 KS23751-L11 KS23751-L5 -- KS23751-L6 KS23751-L9 KS23751-L7 KS23751-L8 -- KS23751-L1 KS23751-L2 KS23751-L3 -- KS23751-L4 -- -- -- -- -- -- *Product designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1, December 1988. Data Sheet: 5007 398 Features and Benefits * Panel mount fuse holder for 70 Type fuses supplied with two screws * Remote alarm capability Typical Applications * Telecommunications DC power circuit protection Catalog Number -- 15087 Accessories Description: Optional color code eyelets used with fuse holder to indicate fuse amp rating. Eyelet Catalog Numbers Catalog Numbers 1A1706-01 1A1706-02 1A1706-03 1A1706-04 1A1706-05 1A1706-06 1A1706-07 1A1706-08 1A1706-09 1A1706-10 1A1706-11 1A1706-12 1A1706-13 1A1706-14 1A1706-15 1A1706-16 1A1706-17 Amp Indication 18 100 2 10 1 4 1 4 1 2 3 4 1 1 1 3 2 3 5 6 8 10 1 10 312 15 100 Color Code Yellow Black Violet Violet/White Red Brown Pink White Orange Blue Green/Black Green/White Brown/White Violet/Yellow Gray/White Black/White Red/White Data Sheet: 5007 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Telcom Protection Products Indicating Fuses and Holders HLS, HLT, PCT GMT Specifications Description: Fuse holders for GMT Type indicating fuses. Poles: 01 to 25. Ratings: Volts: -- 60Vdc/125Vac Agency Information: CE, UL Recognized, Guide IZLT2, File E14853, 15A (60Vdc). Flammability Rating: UL 94V0. Specifications Description: Fast-acting fuses for use in HLT, HLS, and PCT fuse holders. Ratings: Volts: -- 60Vdc/125Vac Amps: -- 18100-15A IR: -- 450A@60Vdc -- 300A@125Vac Agency Information: CE, UL Recognized, Guide JFHR2, File E56412. Flammability Rating: UL 94V0. Features and Benefits * Local and remote indication capability * Color coded for easy amp rating identification Features and Benefits * Multiple configurations provide application flexibility * Compact size saves space Typical Applications * Telecommunications DC power circuit protection GMT - A (Alarm) GMT - Dummy Typical Applications * Telecommunications DC power circuit protection Catalog Numbers Catalog Numbers PCT HLS HLT Catalog Numbers Catalog Numbers GMT-18100A GMT-14A GMT-38A GMT-12A GMT-65100A GMT-34A GMT-1A GMT-1-13A GMT-1-12A GMT-2A GMT-3A Poles 1 See Build-A-Code See Build-A-Code Multiple Fuseholders with bus bars Ordering Information-- Catalog No. Color Code Yellow Violet White/Gray Red Black Brown Gray White White/Yellow Orange Blue Catalog Numbers GMT-3-12A GMT-4A GMT-5A GMT-7-12A GMT-10A GMT-12A GMT-15A GMT-Dummy GMT-X GMT-Y Color Code White/Blue White/Brown Green Black/White Red/White Yellow/Green Red/Blue Gray Body Clear Cover Clear Cover Some GMT sizes may be sold in bulk pack only. Body Style HLT HLS (No flanges) Termination Location No. of Poles 01 thru 25 (Min. of 2 poles required for bus bars) L R (Left only) (Right only) Accessories * Spare fuse holder: Catalog Number TPSFH-T B Type of bus bars used*** B1*, B2, B3, B4, B5, SL** (Short Leads .135") ML** (Medium Leads .250") (Both ends) Bus Bar Position B1 (Angle Bar Only)* B4 (Angle & "L" Bars) B2 ("L" Bar Only) B3 ("U" Bar Only) P2 (Outside-- Both Sides) P3 (Outside-- Right Only) P4 (Outside-- Left Only) Catalog Numbers B5 ("L" & "U" Bars) *Angle Bar mounts on common or center terminals only. **SL Version is not available with bus bars. Minimum of 4 Poles Required. ***.38 max. leads if not specified. Data Sheet: 5010 P1 (Inside-- Both Sides) Specifications Description: Fast-acting fuse designed specifically for use in the Telpower(R) series 15800 fused disconnect switch (page 392). Agency Information: The GMT-A has the same ratings and agency approvals as the standard GMT fuses as shown above. Catalog Number GMT-A Color Code Yellow Data Sheet: 5008 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 399 Telcom Protection Products GMT-A ** Not available with bus bars Telcom Protection Products Telpower Specialty Fuses 7 Type 11 Type Specifications Description: Fiber tube, threaded ends. Typically used on wall type main distribution frames and central battery substations. Dimensions: See Catalog Numbers table and Dimensions illustration. Ratings: Amps: -- 7A Agency Information: CE Specifications Description: Fiber tube, threaded ends, identical to 7 Type except for vent slots in fiber tube. Dimensions: See Dimensions illustration. Ratings: Amps: -- 7A Agency Information: CE Catalog Numbers Catalog Numbers 7A-7 7T-7 Amp Rating 7 7 Lucent Comcode Ref. No. 100863737 100202753 Dimension A Length (in) 4.562 4.828 Catalog Number Catalog Number 11C-7 Amp Rating 7 Lucent Comcode Ref. No. 100863745 Dimensions - in 4.625" 4.062" Dimensions - in A 4.093" 24 and WER Type 74 Type Specifications Description: Flat, non-indicating visible link element mounted on 1 inch centers using either No. 6 or No. 10 screws. Dimensions: See Dimensions illustration. Ratings: Volts: -- 32Vdc ( , 1, 3 12, 8, 10A) -- 60Vdc (12, 34, 1 12, 2, 3, 4, 5A) Amps: -- 14-10A Agency Information: CE, UL Recognized File E56412. Specifications Description: Fast-acting 0.281" x 1.25" cylindrical fuse designed to comply with Lucent specification KS23753. High current companion to 70 Type Fuse. Dimensions: See Dimensions illustration. Ratings: Volts: -- 60Vdc Amps: -- 1 14-20A Agency Information: CE, UL Recognized File E19180. 1 4 Catalog Numbers Catalog Amp Numbers Rating 1 WER-14 4 1 24E-12* 2 3 24D-34* 4 WER-1 1 24G-1-13* 1 13 24C-2* 2 24B-3* 3 WER-3-12 3 12 24B-4* 4 24F-5* 5 WER-8 8 WER-10 10 64A-Dummy -- DC Volts 32 60 60 32 60 60 60 32 60 60 32 32 -- Color Code -- Red Black -- White Orange Blue -- Yellow Green -- -- -- Lucent Comcode Ref. No. -- 100202894 100202886 -- 100202910 100202878 100202852 -- 100202860 100202902 -- -- 100203280 A Length Inches -- 0.20 0.15 -- 0.20 0.20 0.15 -- 0.15 0.15 -- -- -- Catalog Numbers Catalog Amp Lucent Comcode Numbers Rating Ref. No. List No. 102630290 KS23753-L1 74A-1-14 1 14 Code/ 74G-2 2 103064952 KS23753-L7 74B-3 3 102630308 KS23753-L2 74H-4 4 103264669 KS23753-L8 74C-5 5 102630316 KS23753-L3 74J-7-12 7 12 103228425 KS23753-L9 74D-10 10 102630324 KS23753-L4 74E-15 15 102630332 KS23753-L5 74F-20 20 102630340 KS23753-L6 Dimensions - in (mm) *Designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1, Dec. 1988. 1.25" Dimensions - in (31.75mm) A 0.375" 400 0.281" (7.14mm) 1.406" 0.938" A For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Telcom Protection Products Telpower Specialty Fuses 75 Type 76 Type Specifications Description: Cylindrical with leads, designed to provide protection against currents resulting from the application of foreign voltages. Application for data sets and telephones. Dimensions: See Dimensions illustration. Ratings: Volts: -- 135Vac/220Vdc (440Vdc@0.007A) Amps: -- 0.007-0.230A Agency Information: CE Specifications Description: Cylindrical with leads, designed to provide protection against currents resulting from the application of foreign voltages. Application for data sets and telephones. Dimensions: See Dimensions illustration. Ratings: Volts: -- 135Vac/440Vdc Amps: -- 0.012-0.412A Agency Information: CE Catalog Numbers Catalog Numbers Amp Rating Lucent Comcode Ref. No. Code/ List No. 75C 0.007 103260816 Catalog Numbers KS23825-L3 Catalog Numbers Amp Rating Lucent Comcode Code/ Ref. No. List No. 75F 0.063 104172861 KS23825-L6 76D 0.012 103798245 KS23825-L10 75B 0.115 102732112 KS23825-L2 76B 0.191 102965688 KS23825-L8 75D 0.129 104013180 KS23825-L4 76A 0.231 102810181 KS23825-L7 75A 0.200 102660008 KS23825-L1 76C 0.412 103656625 KS23825-L9 75E 0.230 104015292 KS23825-L5 0.620" (8.26mm) (15.75mm) 0.830" (21.08mm) -- --A -- --A Dimensions - in (mm) 0.325" 0.445" (11.30mm) Dimensions - in (mm) 0.320" (8.13mm) 0.190" 1.125" (4.83mm) (28.58mm) 0.800" (20.32mm) 81 Type Specifications Description: A fuse designed for high reliability applications where high ambient temperatures, low circuit voltages, low power dissipation and low contact resistance are prime considerations. The 80 Type is a visual indicating fuse with remote electrical alarm capability. UL Recognized, Guide JDYX2, File E19180. Dimensions: See Dimensions illustrations. Ratings: Volts: -- 160Vdc Amps: -- 12-5A Agency Information: CE, UL Recognized File E19180. Specifications Description: Cylindrical, fast-acting, non-indicating high current companion to the 80 Type. Dimensions: See Dimensions illustration. Ratings: Volts: -- 65Vdc Amps: -- 7 12-12A Agency Information: CE, UL Recognized, Guide JDYX2, File E19180. 81B-7-12 Catalog Numbers Catalog Amp Numbers Rating Color Code Lucent Comcode Code/ Ref. No. List No. 80G-12 1 Red 103839916 80M-1-13 113 White 408078657 KS23824-L8 80B-2 2 Orange 103752150 KS23824-L2 80C-3 3 Blue 103752168 KS23824-L3 80D-5 5 Green 103800637 KS23824-L4 2 Catalog Numbers Catalog Amp Color Numbers Rating Code 7 12 Lucent Comcode Ref. No. Code/ List No. Gray 103828141 KS23824-L12 81A-10 10 Yellow 103752176 KS23824-L11 81C-12 12 Lt Blue 104391842 KS23824-L13 KS23824-L6 Dimensions - in (mm) 2.685" (68.20mm) 0.280" (7.11mm) Dimensions - in (mm) 2.685" (68.20mm) 0.280" (7.11mm) For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 401 Telcom Protection Products 80 Type Telcom Protection Products Filtered Terminal Blocks F38 Series Insertion Loss for 2,500 pF Pi Schematic Typical Insertion Loss* (dB) in 50 Circuit Specifications Description: Terminal blocks for filtering line power in telecommunications applications. Ratings: Volts: -- 240Vac/300Vdc Amps: -- 30A Center Spacing: 0.437" or 716" (11.1mm). Wire Range: # 10-22 AWG Cu. Screw Size: # 8-32 (# 6-32 available, consult factory). Torque Rating: 15 lb-in. Operating Temperature: -55C to +105C. Capacitance: 1,000 pF to 5,000 pF in either C or Pi Schematic. Dielectric Withstanding: 1000Vac/1700Vdc. DC Resistance: 0.01 max. Agency Information: UL/CSA, CE Certified. Flammability Rating: UL 94V0. 30MHz: 42 dB 50MHz: 45 dB 100MHz: 50 dB 300MHz: 68 dB 1000MHz: 70 dB * For other capacitance insertion loss, consult factory. Features and Benefits * Rugged integrated construction of filtering elements around a solid brass pin provides excellent EMI/RFI filtering with high insertion loss for EMI/RFI filtering of AC and DC power and control lines * 2 to 8 terminals standard (up to 16-poles available) with options for straight lead, male or female quick-connect Typical Applications * Cost-effective EMI solution for industrial interconnection filtering Dimensions - in Poles* 2 3 4 5 6 7 8 Front Mount A 1.67 2.10 2.54 2.98 3.41 3.85 4.29 Rear Mount A 1.88 2.32 2.76 3.19 3.63 4.07 4.51 B 1.31 1.75 2.19 2.63 3.06 3.50 3.94 C 0.93 1.37 1.81 2.25 2.68 3.12 3.56 D 0.44 0.88 1.31 1.75 2.19 2.62 3.06 1" = 25.4mm. * Note: Available up to 16-poles. Consult factory. Front Panel Mount (Code 0) Rear Panel Mount (Code 1) Series Terminal Style Mounting # of Poles F38 _ _ 0 = Straight lead 1 = 0.187" Quick connect (male) 2 = 0.187" Quick connect (female) 3 = 0.250" Quick connect (male) 4 = 0.250" Quick connect (female) 0 = Front panel mount 02 to 08* with mount ends 1 = Rear panel mount with #4-40 threaded inserts __ Screw Options Filter Options Capacitance __ _ _ Blank = #8-32, steel, zinc-plated philslot BHMS (standard) 04 = #8-32, Brass, nickel-plated philslot BHMS 92 = #8-32, Steel, zinc-plated slotted BHMS 94 = #8-32, Brass, nickel-plated slotted BHMS C = C Filter P = Pi Filter 1.0 = 1,000 pF +100%-0% 2.5 = 2,500 pF +100%-0% 5.0 = 5,000 pF +100%-0% * Note: Standard is 02-08 poles. Available up to 16-poles. Consult Cooper Bussmann for availability. Special electrical/mechanical configurations are available upon request. 402 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa . Telcom Protection Products Power Feed Through Terminal Blocks Dimensions - in (mm) Series C7021 Catalog Numbers C7021-01-X C7021-02-X C7021-03-X C7021-04-X C7021-05-X C7021-06-X C7021-01N-X C7021-02N-X C7021-03N-X C7021-04N-X C7021-05N-X C7021-06N-X Specifications Description: Power feed through terminal block with two rows 1 4-20 studs capable of accommodating the industry standard two-hole compression lugs on both studs in parallel. Ratings: Volts: -- 300V Amps: -- 115/175A* per pole Center Spacing: 0.690" (17.5mm). Wire Range: AWG #2/0-8. Poles: 2- to 6-poles. Bolt Hole Spacing: 0.625" or 58" (15.88mm). Stud: Standard 14-20 stud (tin-plated brass) or optional M6 stud. Mounting: #6 thread cutting screws (not included) or optional mounting ears. Torque Rating: 36 lb-in. Operating Temperature: 130C. Agency Information: UL/CSA; CE Certified. A B 17.5 34.9 52.3 69.8 87.2 (0.69) (1.37) (2.06) (2.75) (3.44) 17.5 34.9 52.3 69.8 87.2 (0.69) (0.69) (2.06) (2.75) (3.44) C - D 54.4 70.9 89.3 106.8 124.2 36.1 (1.42) 53.5 (2.11) 71.0 (2.80) 88.4 (3.48) 105.9 (4.17) (2.14) (2.83) (3.52) (4.20) (4.89) E 67.3 (2.65) 84.8 (3.34) 102.2 (4.02) 119.7 (4.71) 134.1 (5.40) - - 31.8 49.2 66.7 84.2 101.7 (1.25) (1.94) (2.63) (3.31) (4.00) 31.8 (1.25) 49.2 (1.94) 66.7 (2.63) 84.2 (3.31) 101.7 (4.00) D C 9.6 28.0 (0.38) (1.10) 15.8 (0.62) 5.4 (0.21) 15.8 (0.62) 55.7 (2.19) 12.5 (0.49) O 9.0 TYP (0.35) 7.9 (0.31) 1/4-20 UNC-2A Thread TYP A o12.2 TYP (0.48) B 17.5 TYP (0.69) *175 achieved using both studs in parallel, 115A using a single stud per line. 15.0 TYP (0.59) Typical Applications * Applications requiring up to 175A utilizing a 2-hole compression lug on 58" centers * Input/output block for telecommunications power panels * Use to eliminate busbars 24.0 (0.94) 12.7 (0.50) 33.0 (1.30) 14.5 TYP (0.57) Blind Hole for #6 Thread Cutting Screw 14.5 TYP (0.57) Panel Cutouts E 14.2 ( o.56) A 1.6 (R.06) Series Poles Telcom Protection Products 30.0 (1.18) Mount Ends Studs C7021 - Hardware - 01 02 03 04 05 06 = = = = = = 1-Pole 2-Pole 3-Pole 4-Pole 5-Pole 6-Pole (2 studs) (4 studs) (6 studs) (8 studs) (10 studs) (12 studs) Blank = Mount ends N = No mount ends Blank = Standard M6 = M6 Studs Blank = No hardware 0 = Bulk pack, one set 1 = Bulk pack, two sets 2 = Assembled, bottom 3 = Assembled, top 4 = Assembled, both sets For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 403 Telcom Protection Products Power Feed Through Terminal Blocks Series C7024 Specifications Description: A power feed through terminal block with two rows of 14-28 studs capable of accommodating the industry standard two-hole compression lugs on 34" centers. Dimensions: See Dimensions illustration. Ratings: Volts: -- 600V Amps: -- 115A per pole Center Spacing: 0.75" (19.1mm). Wire Range: #2-8 AWG. Poles: 1 to 12. Bolt Hole Spacing: 0.75" (19.1mm). Stud: Standard 14-28 stud (tin-plated bronze). Torque Rating: 36 lb-in. Operating Temperature: 130C. Agency Information: UL/C-UL, CSA; CE Certified. Flammability Rating: UL 94V0. Typical Applications * Applications requiring up to 115A utilizing a 2-hole compression lug on 34" centers * Ideal as an input/output block for telecommunications power panels * Use to eliminate busbars Dimensions - mm (in) O17.780 TYP [0.700] MIN. AT STUD PAD 13.2TYP [0.52] 0.5 TYP [0.02 ] Catalog Numbers Catalog Number C7024-01 C7024-02 C7024-03 C7024-04 C7024-05 C7024-06 C7024-07 C7024-08 C7024-09 C7024-10 C7024-11 C7024-12 Series Poles 01 02 03 04 05 06 07 08 09 10 11 12 "A" Dimension- mm (in) 0.4 (0.02) "B" Dimension- mm (in) 21.6 (0.85) 40.6 (1.60) 19.05 0.08 (0.750 0.003) 59.7 (2.35) 38.10 (1.500) 78.7 (3.10) 57.15 0.26 (2.250 0.010) 97.8 (3.85) 76.2 (3.00) 116.8 (4.60) 95.25 0.26 (3.750 0.010) 135.9 (5.35) 114.30 0.38 (5.250 0/015) 154.9 (6.10) 133.35 0.38 (5.25 0.015) 174.0 (6.85) 152.40 0.38 (6.00 0.015) 193.0 (7.60) 171.45 0.38 (6.750 0.015) 212.1 (8.35) 190.50 0.38 (7.500 0.015) 231.1 (9.10) 209.55 0.38 (8.250 0.015) B A 16.53TYP [0.651] 28.0 [1.10] 17.8TYP [0.70] 2.70TYP [ 0.106 ] 3.16TYP [0.124] O14.4 [0.57] 19.06 0.08 [ 0.750 0.003] 40.6 [1.60] Poles C7024 - 01-12 404 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Surge Protection Devices Section Contents TVS voltage surge suppressors . . . . . . . . . . . TVSS surge protection limiters . . . . . . . . . . Page 406 407 Surge Protection Devices 405 Surge Protection Devices Voltage Surge Protectors TVS -- Cooper Bussmann(R) Surge3TM Dimensions - in (mm) Suppressor Module A. 1.88 (47.75) B. 0.75 (19.05) C. 1.00 (25.40) D. 0.31 (7.94) E. 0.04 (1.02) F. 0.63 (15.88) G. 0.27 (6.86) Specifications Description: DIN rail mount voltage surge protection system for AC or DC voltage using diode or MOV technology. Dimensions: See Dimensions illustration. DIN Rail Mount Holder H. 2.30 (58.42) I. 0.76 (19.30) J. 1.27 (32.18) K. 0.15 (3.81) Construction: Suppressor Module: 20% glass-filled PES (Polyethersulfone) case with 110 copper terminals with electroless tin plating. DIN Rail Mount Holder: 15% glass-filled PBT (Polybutylene terephthalate) case with electroless tin-plated CDA 7025 interface clips lubricated with fluoroether grease, copper box lugs and stainless steel DIN rail springs. Ratings*: Volts: -- 12Vdc (2kA surge current) -- 24Vdc (2kA surge current) -- 48Vdc (2kA surge current) -- 120Vac (7kA-18kA surge current) -- 240Vac (7kA-18kA surge current) * See Catalog Numbers table for all specifications pertaining to specific voltage ratings. Agency Information: UL Recognized (UL 1449) for AC products, (UL 497B) for DC products, CSA Approved. To see our entire surge protection device portfolio, contact your Cooper Bussmann sales representative, the factory or visit our website. Catalog Numbers Catalog Numbers TVS12DCD TVS24DCD TVS48DCD TVS120ACD TVS120ACM TVS240ACD TVS240ACM Voltage Application 12Vdc 24Vdc 48Vdc 120Vac 120Vac 240Vac 240Vac MCOV 14Vdc 28Vdc 57Vdc 140Vac 140Vac 280Vac 280Vac Technology SASD SASD SASD SASD MOV SASD MOV SVR 500A, 8x20s 36Vdc 58Vdc 90Vdc 330Vac 500Vac 600Vac 800Vac Surge Current Rating 2kA 2kA 2kA 7kA 18kA 7kA 18kA Agency Information UL 497B UL 497B UL 497B UL 1449 UL 1449 UL 1449 UL 1449 Data Sheet: 9006 406 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Label Color Red White Black Blue Grey Blue Grey Surge Protection Devices Surge Protection Limiters Dimensions TVSS Ferrule Style 1.500 0.031 [38.1 0.79] 0.406 0.066 [10 0.15] Specifications Description: Surge protection limiters designed to protect TVSS systems. Apply in conjunction with TVS voltage surge protector to provide complete surge protection. Able to withstand 8x20 Sec surge pulses without opening. Limiters are identified by a surge rating and not continuous current rating. Available with optional printed circuit board tabs. Dimensions: See Dimensions illustration. Construction: Melamine tube with nickel-plated brass end caps. Ratings*: Volts: -- 600Vac IR: -- 200kA RMS Sym. Optional Printed Circuit Board Tabs 0.019 [.48] 1.540 0.015 [39.12 0.38] 0.406 0.066 [10 0.15] * See Catalog Numbers table for all specifications pertaining to specific ratings. 0.500 [12.70] Agency Information: CE, UL Recognized 600Vac, File E56412. Designed to protect TVSS systems per UL 1449 Second Edition requirements. Features and Benefits * Optional tabs for mounting on printed circuit board. 0.120 [3.05] 0.120 [3.05] Catalog Numbers Catalog Numbers TVSS-5 TVSS-10 TVSS-15 TVSS-20 8x20S Surge Rating 5,000A 10,000A 15,000A 20,000A Melting I2t (A2 Sec) 559 1,788 3,760 6,020 Clearing I2t (A2 Sec) 1,650 5,766 9,730 14.000 Ipeak @ 100kA 60Hz (A) 4,283 6,618 7,843 8.594 Above catalog numbers are available with printed circuit board tabs. When ordering, use suffix "-01". Surge Protection Devices Recommended fuse blocks/fuse holders for 1332" x 112" fuses -- See Data Sheets * * * * Open fuse blocks - 1104, 2104 Finger-safe fuse holders - 1109, 1102, 1103, 2053 Panel-mount fuse holders - 2114, 2113, 2108 In-line fuse holders - 2127, 2126 Data Sheet: 2141 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 407 408 Reduce Downtime With Quick Access to the Right Replacement Fuse Section Contents Page Fuse service kits - supplemental . . . . . . . . . . . . . 410-411 Fuse service kits - branch circuit . . . . . . . . . . . . . 410-411 Fuse service kits - premium branch circuit . . . . . 410-411 Large electronic fuse kit - 270 . . . . . . . . . . . . . . . . . . . 412 Small electronic fuse kit - 140 . . . . . . . . . . . . . . . . . . . 412 Electrical and electtronic fuse kit 5 x 20mm fuse kit 220 . . . . . . . . . . . . . . . . . . . . . . . . . . 412 Clip clamps & rail adapters (DIN & American) . . . . 413 Spare fuse holders, pullers, testers & cabinets Telpower(R) spare fuse holders . . . . . . . . . . . . . . . . . . . . .414 5TPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .414 Fuse pullers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .414 FT-2 & FT-3 fuse testers . . . . . . . . . . . . . . . . . . . . . . . . 414 SFC spare fuse cabinet . . . . . . . . . . . . . . . . . . . . . . . . . 414 Fuse reducers & dummy "neutrals" Class J dimension fuses - LPJ, JKS. . . . . . . . . . . . . . . . 415 Class R dimension fuses FRN-R, LPN-RK, FRS-R & LPS-RK . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415 Class H & K dimension fuses NON, REN, NOS & RES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415 Dummy fuse "neutrals" . . . . . . . . . . . . . . . . . . . . . . . . . 415 Accessories 409 Fuse Kits and Accessories Fuse Service Kits Save Time and Money with These Fuse Service Kits Selection Organization Accessories These service kits are filled with the most common fuse types and sizes for the most common applications - no need to search for the right fuse, it's in the kit. The compact and sturdy carrying case allows organizing and modifying the fuses needed to assure a proper supply is kept on hand. All kits come with a fuse puller for the fuses it contains. As a bonus, all kits on this page include a free wire stripper or lineman's pliers. Supplemental Branch Circuit Premium Branch Circuit Glass Fuse Kit Class CC Fuse Kit Low-Peak(R) Class RK1 250/600V Fuse Kit Catalog Number: GSK-260 Kit Contents (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (1) (1) GMA-500mA (5) MDL-6 GMA-1A (5) MDL-7 GMA-2A (5) MDL-8 GMA-3A (5) MDL-10 GMA-4A (5) MDL-15 GMA-5A (5) MDL-20 GMA-6A (5) AGC-14 GMA-10A (5) AGC-12 GMA-15A (5) AGC-1 MDL-14 (5) AGC-112 (5) AGC-2 MDL-12 MDL-1 (5) AGC-212 1 MDL-1 2 (5) AGC-3 MDL-2 (5) AGC-4 1 (5) AGC-5 MDL-2 2 MDL-3 (5) AGC-6 MDL-4 (5) AGC-7 MDL-5 (5) AGC-8 FT-3 Fuse tester/puller 6-inch Crescent(R) wire stripper (5) AGC-10 (5) AGC-15 (5) AGC-20 (5) GMC-2A (5) GMC-5A (5) GMC-10A (5) MDA-5 (5) MDA-10 (5) MDA-12 (5) MDA-15 (5) MDA-20 (5) ABC-5 (5) ABC-10 (5) ABC-12 (5) ABC-15 (5) ABC-20 Catalog Number: CCSK-45 Kit Contents (3) (3) (3) (3) (3) (3) (3) (1) (1) LP-CC-5 (3) KTK-R-15 LP-CC-10 (3) KTK-R-20 LP-CC-15 (3) KTK-R-30 LP-CC-20 (3) FNQ-R-12 LP-CC-30 (3) FNQ-R-3 KTK-R-5 (3) FNQ-R-5 KTK-R-10 (3) FNQ-R-10 FT-3 Fuse tester/puller 6-inch Crescent(R) wire stripper Catalog Number: RK1SK-39 Kit Contents (3) (3) (3) (3) (3) (3) (3) (1) (1) (1) (1) LPN-RK-10SP (3) LPS-RK-10SP LPN-RK-15SP (3) LPS-RK-15SP LPN-RK-20SP (3) LPS-RK-20SP LPN-RK-25SP (3) LPS-RK-30SP LPN-RK-30SP (3) LPS-RK-60SP LPN-RK-60SP (3) LPS-RK-100SP LPN-RK-100SP NO.263-R (60 to 30A fuse reducer) NO.663-R (60 to 30A fuse reducer) FP-2 Fuse puller 858-inch Crescent(R) lineman's pliers Fusetron(R) Class RK5 250/600V Fuse Kit Catalog Number: RK5SK-39 Midget Fuse Kit Catalog Number: MSK-45 Kit Contents (3) (3) (3) (3) (3) (3) (3) (3) (1) FNM-1 (3) KTK-20 FNM-2 (3) KTK-30 FNM-5 (3) FNQ-5 FNM-10 (3) FNQ-10 FNM-15 (3) FNQ-15 KTK-5 (3) FNQ-20 KTK-10 (3) FNQ-30 KTK-15 (1) FT-3 Fuse tester/puller 6-inch Crescent(R) wire stripper 410 Kit Contents (3) (3) (3) (3) (3) (3) (3) (1) (1) (1) FRN-R-10 (3) FRS-R-10 FRN-R-15 (3) FRS-R-15 FRN-R-20 (3) FRS-R-20 FRN-R-25 (3) FRS-R-30 FRN-R-30 (3) FRS-R-60 FRN-R-60 (3) FRS-R-100 FRN-R-100 (1) FP-2 Fuse puller NO.263-R (60 to 30A fuse reducer) NO.663-R (60 to 30A fuse reducer) 6-inch Crescent(R) wire stripper Low-Peak(R) Class J Fuse Kit Catalog Number: JSK-36 Kit Contents (3) (3) (3) (3) (3) (3) (1) (1) LPJ-3SP (3) LPJ-25SP LPJ-5SP (3) LPJ-30SP LPJ-6SP (3) LPJ-40SP LPJ-10SP (3) LPJ-50SP LPJ-15SP (3) LPJ-60SP LPJ-20SP (3) LPJ-100SP FP-2 Fuse puller 858-inch Crescent(R) lineman's pliers For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Kits and Accessories Fuse Service Kits Supplemental/Branch Circuit Branch Circuit Premium Branch Circuit Class CC / Midget Fuse Kit Fusetron(R) Class RK5 250V Fuse Kit Low-Peak(R) Class RK1 250V Fuse Kit Emergency fuse kit for replacement of 13 32" x 112" (Class CC and midget) fuses in a sturdy nylon box. Cross reference makes it easy to install the correct fuse in any Class CC or midget application. Kit Size: 1078" W x 658" D x 134" H Catalog Number: NO.36 Emergency Kit Contents (2) (2) (2) (2) (2) (2) (2) (2) (2) (1) FNQ-R-12 FNQ-R-1 FNQ-R-2 FNQ-R-3 FNQ-R-4 FNQ-R-5 FNQ-10 FNQ-15 FNQ-20 FP-2 Fuse puller (2) (2) (2) (2) (2) (2) (2) (2) (2) KTK-R-1 KTK-R-2 KTK-R-3 KTK-R-5 KTK-R-6 KTK-R-10 KTK-R-15 KTK-R-20 KTK-R-30 Compact kit in a sturdy nylon box rugged enough to withstand field use. Extra spaces and changeable compartments make it easy to customize for your particular need. Compact kit in a sturdy nylon box rugged enough to withstand field use. Extra spaces and changeable compartments make it easy to customize for your particular need. Catalog Number: ERK-28 Catalog Number: LPRK-28 Service Kit Contents (2) (2) (2) (2) (3) (2) (4) (2) FRN-R-3-210 FRN-R-6-14 FRN-R-10 FRN-R-15 FRN-R-20 FRN-R-25 FRN-R-30 FRN-R-35 (2) (2) (3) (2) (2) (2) (2) FRN-R-40 FRN-R-50 FRN-R-60 FRN-R-100 NO.263-R Reducers NO.1 Clip Clamps NO.2 Clip Clamps Service Kit Contents (2) (2) (2) (2) (3) (2) (4) (2) LPN-RK-3-210SP LPN-RK-6-14SP LPN-RK-10SP LPN-RK-15SP LPN-RK-20SP LPN-RK-25SP LPN-RK-30SP LPN-RK-35SP (2) (2) (3) (2) (2) (2) (2) (1) LPN-RK-40SP LPN-RK-50SP LPN-RK-60SP LPN-RK-100SP NO.263-R Reducers NO.1 Clip Clamps NO.2 Clip Clamps FP-2 Fuse puller Accessories For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 411 Fuse Kits and Accessories Fuse Service Kits Large Electronic Fuse Kit Small Electronic Fuse Kit Electrical and Electronic Fuse Kit Fuse Kit 270 Fuse Kit 140 5 x 20mm Fuse Kit 220 Small dimension fuse assortment with 270 fuses, fuse holders, fuse blocks and fuse clips to fit most electronic equipment. Ratings: Volts: -- 125V/250V Small dimension fuse kit with 140 fuses, fuse holders, fuse blocks and fuse clips to fit most electronic equipment. Ratings: Volts: -- 125V/250V Catalog Number: NO.270 Catalog Number: NO.140 Assortment Contents Assortment Contents (5) MDL-18 (5) AGC-12 (5) MDL-14 (5) AGC-34 (5) MDL-12 (5) AGC-1 (5) MDL-34 (5) AGC-1-12 (5) MDL-1 (5) AGC-2 (5) AGC-2-12 (5) MDL-1-12 (5) MDL-2 (5) AGC-3 (5) MDL-3 (5) AGC-4 (5) MDL-4 (5) AGC-5 (5) MDL-5 (5) AGC-6 (5) MDL-6 (5) AGC-7 (5) MDA-8 (5) AGC-8 (5) MDA-10 (5) ABC-10 (5) MDA-15 (5) ABC-15 (5) MDA-20 (5) ABC-20 (5) MDA-30 (5) ABC-30 (5) AGC-18 (5) GMA-250mA (5) GMA-500mA (5) AGC-14 (2) Pr. 4121 Fuse clips (2) HHB Inline fuse holder (1) HTB-26I panel mount fuse holder (1) HTB-28M panel mount fuse holder (1) S-8202-2 Two-pole fuse block 412 (5) GMA-1A (5) GMA-2A (5) GMA-3A (5) GMA-4A (5) GMA-6A (5) GMC-1A (5) GMC-2A (5) GMC-3A (5) GMC-4A (5) GMC-6A (4) AGC-V-12 (4) AGC-V-1 (4) AGC-V-2 (4) AGC-V-3 (4) MDL-V-12 (4) MDL-V-1 (4) MDL-V-2 (4) MDL-V-3 (5) MDL-12 (5) MDL-1 (5) MDL-1-12 (5) MDQ-2 (5) MDQ-3 (5) MDQ-4 (5) MDQ-5 (5) MDQ-6 (5) MDA-8 (5) MDA-10 (5) MDA-15 (5) MDA-20 (5) MDA-30 (5) AGC-14 (5) AGC-12 (5) AGC-1 (5) AGC-1-12 (5) AGC-2 (5) AGC-3 (5) MTH-4 (5) MTH-5 (5) MTH-6 (5) MTH-7 (5) MTH-8 (5) ABC-10 (5) ABC-15 (5) ABC-20 (5) ABC-30 (2) Pr. #4121 Fuse clips (2) HHB Inline fuse holder (1) FP-A3 Fuse puller A complete assortment of 125V and 250V 5 x 20mm fuses for the repair of both electrical and electronic devices. Ratings: Volts: -- 125V/250V Catalog Number: NO.220 Assortment Contents (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (5) (1) (1) GMA-250mA (5) GDA-6.3 (5) GMA-500mA (5) GDB-630mA (5) GMA-1 (5) GDB-2 (5) GMA-1.5 (5) GDB-3.15 (5) GMA-2 (5) GDB-4 (5) GMA-2.5 (5) GMC-500mA (5) GMA-3 (5) GMC-750mA (5) GMA-4 (5) GMC-1 (5) GMA-5 (5) GMC-2 (5) GMA-10 (5) GMC-2.5 (5) GDA-630mA (5) GMC-3 (5) GDA-1 (5) GMC-3.15 (5) GDA-2 (5) GMC-4 (5) GDA-3.15 (5) GMC-5 (5) GDA-5 (5) GMC-6.3 HTB-28M panel mount fuse holder FP-A3 Fuse puller For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa GMD-200mA GMD-500mA GMD-1 GMD-1.6 GMD-2 GMD-3 GDC-250mA GDC-500mA GDC-1 GDC-1.6 GDC-2 GDC-3.15 GDC-4 GDC-5 Fuse Kits and Accessories Clip Clamps and Rail Adapters (DIN & American) TRONTM Clip-Clamps Specifications Description: Clamps for ferrule and bladetype cartridge fuse clips. Provide tight contacts between fuse holder clips and fuse ferrules/blades. Construction: Phenolic knob and plated-steel jaws. Catalog Numbers Catalog Numbers NO.1 NO.2 NO.2 NO.4 NO.5 NO.6 NO.7 NO.8 Clamp Size Volts 250 250 600 600 250/600 250/600 250/600 250/600 Amps 0-30 35-60 0-30 35-60 70-100 110-200 225-400 450-600 Adapters for DIN and American Rails Specifications Description: Cooper Bussmann(R) DIN rail adapters permit secure, positive snap-on mounting of Cooper Bussmann 0-30A fuse blocks (one-, two-, or three-pole) onto various size rails to eliminate costly and time consuming drilling, tapping, and screw mounting. Adapters mechanically lock into mounting holes of fuse blocks in seconds to become an integral part of the block. One adapter is required for one- and two-pole Cooper Bussmann blocks. Two adapters are required for three-pole blocks. With the exception of the 32mm DIN rail, all blocks with adapters can be removed from a rail simply by pulling up its release tab. Use of rail end-stops on both sides of adapters is recommended. Construction: Molded from "LexanTM 241" for high strength and flexibility. Catalog Numbers (For 0-30A Fuse Blocks) Catalog Numbers DRA-1 DRA-2 Fuse Block Class CC G *H (250V) *R (250) M Type Rail Type DIN American Size 15mm (Sym.) 32mm (Asym.) 35mm (Sym.) 17 64" (Sym.) (also 35mm DIN) Adapter Color Black Gray Package Quantities: standard--10; bulk--100 (Cat. No. BK/DRA-1 or BK/DRA-2.) *Mounting on 15mm rails is not recommended. NOTE--Newer Cooper Bussmann fuse blocks have elongated block-to-adapter mounting Accessories For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 413 Fuse Kits and Accessories Spare Fuse Holders, Pullers, Testers and Cabinets Spare Fuse Holders Fuse Pullers FP-2 SFC Spare Fuse Cabinet FP-6 FP-3 Specifications Description: Spare fuse holders durably constructed using black thermoplastic with common mounting using #6 screws or bolts on 5-inch centers. Dovetailed interlocking between fuse holders simplifies installation and reduces needed hardware. Common footprint allows for any combination of fuse holders to be mounted together. Built-in retaining clips secure fuses. Flammability Rating: UL 94V0. Catalog Numbers Catalog Numbers TPSFH-CW TPSFH-M TPSFH-70 TPSFH-LC TPSFH-LB TPSFH-N60 TPSFH-N30 TPSFH-AS TPSFH-T Capacity 4-position 4-position 12-position 1-position 1-position 1-position 4-position 6-position 10-position For Use With: TPC and/or TPW fuses TPM fuses Series 70 fuses TPL-C series fuses TPL-B series fuses TPN (35-60A) fuses TPN (1-30A) fuses TPA & TPS fuses GMT fuses FP-A3 FP-4 Specifications Description: Fuse pullers in various sizes to safely and easily extract fuses from blocks and holders. Catalog Numbers Ca talog Numbers Application 13 FP-2 32" to 1316" dia. fuses FP-3 1" to 1 34" dia. fuses FP-4 1 34" to 2 12" dia. fuses FP-6 0-60A T-Tron fuses FP-A3 Glass Tube & ATC fuses Fuse pullers are only to be used when the associated circuit has been de-energized. Specifications Description: Spare fuse cabinet with five cubic feet of storage space. Constructed of heavy gauge steel with durable baked ASA 61 grey enamel finish. Cabinet door is equipped with locking handle for security. Mounting holes are 16 inches on center with with key slots. Size: 24" W x 30" H x 12" D Material: 0.062 sheet steel Catalog Numbers: SFC-FUSE-CAB FT-2 Fuse Tester SFC-SHELF* *Extra shelf for fuse cabinet. Data Sheet: 1119 FT-3 Fuse Tester 5TPH Specifications Description: 5-position spare fuse holder for midget size and Class CC fuses (1332" diameter) fuses. Constructed of thermoplastic with adhesive tape on back for easy mounting on cabinet doors. Size: 2.98" W x 1.03" H x 0.63" D Catalog Number: 5TPH Data Sheet: 5014 414 Specifications Description: Fuse tester for automotive, glass tube and ferrule fuses up to 178" length. Probe slides to appropriate fuse length. Batteries are included and replaceable. WARNING: DO NOT test electrical fuses in the fuse panel. Catalog Number: FT-2 Specifications Description: Fuse tester for automotive, glass tube and ferrule fuses up to 114" length. Probe slides to appropriate fuse length. Batteries are included and replaceable. WARNING: DO NOT test electrical fuses in the fuse panel. Catalog Number: FT-3 Replacement Battery: Rayovac 364 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Fuse Kits and Accessories Fuse Reducers and Dummy "Neutrals" Fuse Reducers for Class J Dimension Fuses: LPJ, DFJ, JKS Catalog Numbers Catalog Numbers (Pair) Reducer No. J-63 J-13 J-16 J-26 J-21 J-41 J-42 J-62 J-64 Dummy Fuse "Neutrals" (These are not fuses) Catalog Numbers Fuse Amp Size Range 1-30 1-30 35-60 35-60 70-100 70-100 110-200 110-200 225-400 Equipment/Fuseblock Amp Size 60 100 100 200 200 400 400 600 600 Not for Bolt-on Applications. Fuse Reducers for Class R Dimension Fuses: FRN-R, LPN-RK, FRS-R, LPS-RK KTN-R, KTS-R Fuse Equivalent Catalog Numbers NNB NNB-R NNC NTN-R-30 NTN-R-60 NTN-R-100 NTN-R-200 NTN-R-400 NTS-R-30 NTS-R-60 NTS-R-100 NTS-R-200 NTS-R-400 NTS-R-600 Voltage -- -- -- 250 250 250 250 250 600 600 600 600 600 600 Dimension 13 32" x 112" Class CC 1 4" x 114" R/H R/H R/H R/H R/H R/H R/H R/H R/H R/H R/H Fuse Amp Size Range -- -- -- 1-30 35-60 70-100 110-200 225-400 1-30 35-60 70-100 110-200 225-400 450-600 UL Listed File E12853 Catalog Numbers Catalog Numbers (Pairs) Voltages Fuse Equipment/Fuseblock 250V 600V Amp Size Range Amp Size NO.263-R NO.663-R 1-30 60 NO.213-R NO.216-R 1-30 100 NO.216-R NO.616-R 35-60 100 NO.226-R NO.626-R 35-60 200 NO.2621-R* NO.2621-R 70-100 200 NO.2641-R NO.2641-R 70-100 400 NO.242-R NO.642-R 110-200 400 NO.2661-R NO.2661-R 70-100 600 NO.2662-R NO.2662-R 110-200 600 NO.2664-R** NO.2664-R** 225-400 600 *Reducer NO.2621-R does not apply to LPN-RK-70SP to LPN-RK-100SP Fuses. **Single reducer only (pair not required). Fuse Reducers for Class H & K Dimension Fuses: NON, REN, NOS, RES UL Listed File E12853 Catalog Numbers 600V Reducer NO.663 NO.216 NO.616 NO.626 NO.2621 NO.2641 NO.2642 Fuse Amp Size Range 1-30 1-30 35-60 35-60 70-100 70-100 110-200 Accessories Catalog Numbers. (Pairs) 250V Reducer NO.263 NO.213 NO.216 NO.226 NO.2621 NO.2641 NO.2642 Equipment/ Fuseblock Amp Size 60 100 100 200 200 400 400 Data Sheet: 1118 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 415 416 Cooper Bussmann Services & Application Guide Downtime Reduction, Workplace Safety & Code Compliance Services to Increase Your Productivity Through Protection Section Contents Cooper Bussmann Services Engineering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .418 Engineering - OSCARTM 2.0 Compliance Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .419-420 Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .421 Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 422 Custom Products . . . . . . . . . . . . . . . . . . . . . . . . . 423 Application Guide Fuse technology . . . . . . . . . . . . . . . . . . . . . . . . . . .424-430 Motor circuit branch circuit protection . . . . . . . . . . . . . . .431 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432-434 Out-of-stock substitution/upgrades . . . . . . . . . . . . . . . . 434 Industrial & commercial fuse applications . . . . . . . . . . . 435 Catalog number index . . . . . . . . . . . . . . . . . 436-440 Sales support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .441 RED indicates NEW information Services & Application Guide 417 Services Engineering (R) 2 7 3 6 (R) (R) Our comprehensive service offerings include: 1 - Electrical System One-Line Diagram Development 2 - Short-Circuit Current Analysis 3 - Overcurrent Protective Device Time-Current Curve Characteristic 4 - Overcurrent Protective Device Coordination Analysis 5 - Arc-Flash Hazard Analysis 6 - Arc-Flash Hazard Label Production 7 - Electrical Safety Training 8 - Annual Maintenance 1 8 (R) Arc-Flash Safety and Productivity The Cooper Bussmann(R) Services team has the experience in power system design, analysis and electrical safety to best assess and make recommendations that offer maximum protection and productivity. We go beyond just understanding electrical standards and regulations, actively participating in improving circuit protection and electrical safety. To Order: To find out more contact your local Cooper Bussmann representative, or visit us online at www.cooperbussmann.com/services. 5 Engineering Catalog Numbers Description 418 Catalog Number One Line Description Development CBSV-ES-EN1 Data Collection CBSV-ES-EN2 Short-Circuit Study CBSV-ES-EN3 Selective Coordination Study CBSV-ES-EN4 Arc-Flash Study CBSV-ES-EN5 Labeling CBSV-ES-EN6 Arc-Flash Training CBSV-ES-EN7 Maintenace Plan for Arc-Flash Study CBSV-ES-EN8 Visit www.cooperbussmann.com/services 4 Services Engineering - OSCARTM 2.0 Compliance Software Calculate Assembly SCCR with Ease & Confidence Enhanced Cooper Bussmann(R) OSCARTM Software Speeds Code & Standards Compliance The new Cooper Bussmann(R) OSCARTM Version 2.0 SCCR (Short-Circuit Current Rating) compliance software easily guides you through entering your electrical panel's components and calculates an assembly SCCR. This award winning, online, essential design tool allows you to comply quickly and accurately with 2008 NEC(R) and UL 508A Supplement SB for assembly SCCR marking requirements: * Industrial Control Panels [409.110] * Industrial Machinery Electrical Panels [670.3(A)] * HVAC Equipment [440.4(B)] 2006 New Project Management Features: * Simplify your panel design and project organization. * Save and edit existing panel designs. * Save multiple panels under a single project. * Copy existing panels to new projects. New Intuitive Navigation: * Display your one-line diagram. * Select from pre-loaded circuit templates. * Identify the weakest link component automatically. * Print reports and one-line diagrams for required SCCR documentation. * Utilize mouse-over tips to enhance your design. Design with Confidence: * Logic updated to current UL requirements. * Extensive 55,000+ component database. * Search by partial part number or device rating. * Custom device option allows for entering specialized component rating information. To Subscribe: Contact your local Cooper Bussmann distributor, or visit us online at www.cooperbussmann.com/oscar. Catalog Number CBSV-SC-EN8 Visit www.cooperbussmann.com/oscar Services & Application Guide Order Information Description OSCARTM 2.0 Compliance Software Annual Subscription 419 Services Engineering - OSCARTM 2.0 Compliance Software Cooper Bussmann(R) OSCARTM 2.0 Software The Cooper Bussmann OSCAR 2.0 Compliance Software is maintained online to provide you with the most current UL design standards, and to continuously update our product search database with new components and their individual ratings. This software is available 24/7--365 with a one-year subscription. New User Interface Displays Panel Information Including Assembly SCCR Displays Actual One-Line Diagram Easily Search the OSCAR Database to Aid in Design & Part Selection Red Circle Easily Identifies "Weakest Link" Component Limiting Assembly SCCR Drop-Down Menus Enhance Search Capabilities Improved Results & Documentation Detailed Online Report or Print Option Additional Features: * Simplify your panel design and project organization with the My Projects feature. * Copy existing designs to new projects. * Display your one-line diagram as each component is added through the new build-a-circuit graphical interface. * Save and edit existing panel designs. * Save multiple panels under a single project. * Select from pre-loaded templates of common circuit types for faster design development. * Detect combination ratings automatically. * Utilize mouse-over tips to enhance your design. Computer System Requirements: All calculating activity takes place on the Cooper Bussmann server. Your computer only needs to have sufficient band width access to the Internet and the minimum requirements listed below. Performance is optimized by utilizing Internet Explorer and a PC. Apple/Macintosh computers and other web browsers may compromise OSCAR 2.0 performance. * Computer: Pentium 1 PC or equivalent * Web Browser: Internet Explorer 5.5 with Java script and cookies enabled * Internet Connection: ADSL minimum 420 Visit www.cooperbussmann.com/oscar Services Training Knowledge That Minimizes Risk to Maximize Productivity and Protection Technology evolves, the Code and standards change, and new personnel are joining your operation. How do you manage this changing environment while still focusing on what you do best - running your operation? Expert training from Cooper Bussmann is the solution. We provide the training when and where you need it. Cooper Bussmann can deliver our world-class safety and technical training on-site at your facility or ours. Training: To arrange a Cooper Bussmann(R) training seminar, contact your local Cooper Bussmann representative, or e-mail us at services@cooperbussmann.com. Publications and e-Training Modules Cooper Bussmann(R) Services has developed advanced, value-added technical resources to meet the more demanding needs around Code compliance, and electrical design and safety. How To Order: Training Catalog Numbers For detailed descriptions on Description this portfolio visit Designing Commercial & Industrial Power Systems Per Person www.cooperbussmann.com/services. Understanding Short-Circuit Current Rating Basics 1 Hour Hardcopy materials are available 2 Hour through your local Cooper Bussmann Designing Panels with Higher SCCRs distributor. Understanding Electrical Safety Basics 1 Hour Electrical Hazards and Designing for Safety 2 Hour Catalog Number CBSV-ES-ED1 CBTR-SC-1HP CBTR-SC-2HP CBTR-ES-1HP CBTR-ES-2HP 8 Hours (0.8 CEU) CBTR-ES-1DA Safety Basics User Kit Hard Copy CBSV-ES-ED3 Safety Basics Trainer Kit Hard Copy CBSV-ES-ED4 Safety Basics Video (VHS) Hard Copy CBSV-ES-ED5 Safety Basics CD Hard Copy CBSV-ES-ED6 Safety Basics Handbook Hard Copy CBPUB-ES-ED1H Selecting Protective Devices (SPD) Hard Copy CBPUB-ES-ED2H Electrical Plan Review (EPR) and Answer Sheet Hard Copy CBPUB-ES-ED3H Interrupting Rating Overcurrent Protection DVD Hard Copy CBPUB-ES-ED30H Selective Coordination: Preventing Blackouts DVD Hard Copy CBPUB-ES-ED31H Current Limitation Overcurrent Protection DVD Hard Copy CBPUB-ES-ED32H Motor Starter Protection: Overcurrent DVD Hard Copy CBPUB-ES-ED33H Motor Protection DVD Hard Copy CBPUB-ES-ED34H Specification Grade Protection DVD Hard Copy CBPUB-ES-ED35H Overcurrent Protection 6 DVD Set Hard Copy CBPUB-ES-ED36H Visit www.cooperbussmann.com/services 421 Services & Application Guide NFPA 70E Workplace Guidelines Services Testing Performance and Compliance Certification for Components and Assemblies The Cooper Bussmann(R) Paul P. Gubany Center for High Power Technology at Cooper Bussmann is the electrical industry's most comprehensive facility for testing and certifying electrical components and assemblies. OEM customers make the Gubany Center their first choice in testing equipment such as: * Drives, both AC and DC * Circuit breakers * Motor control centers * Soft starters * Fuses * Power distribution panels * Surge suppressors * Cables Wide Range of Capability Built to exceed the short circuit capacity of today's high power electrical distribution systems, the Gubany Center performs: * Ultra-high power testing from 200kA to 300kA at 600Vac, three-phase * Medium power testing from 5kA to 200kA at 600Vac, singleand three-phase; to 100kA at 1450Vac single-phase; to 100kA at 1000Vdc * Low power testing up to 5kA at 600Vac, single-phase. Our technicians conduct tests to many global agency standards including: * ANCE * ETL * ANSI * IEC, and * CE * Underwriters Laboratories * CSA To Order: To find out more contact your local Cooper Bussmann representative, or visit us online at www.cooperbussmann.com/services. 422 Testing Catalog Numbers Description Catalog Number High Power Testing Hourly Rate Medium Power Testing Hourly Rate CBSV-ES-TEMP Low Power Testing Hourly Rate CBSV-ES-TELP Visit www.cooperbussmann.com CBSV-ES-TEHP Services Custom Products Creating the Right Answers to Unique or Demanding Needs When you wish to gain a competitive edge or improve your product's performance, have Cooper Busmann provide a custom product that can: * Improve functionality and utility * Fit unique design needs * Reduce labor and component costs Our Expertise Is Your Advantage For over 90 years, Cooper Bussmann has designed and manufactured products that improve electrical safety and performance. Whether it's modifying an existing product or creating a new one, our experience effectively brings together the skills to design, prototype, test, manufacture and secure agency approvals to deliver a single component, sub-assembly or finished product. Cooper Busman can design and manufacture products that integrate: * Fuses - with the right size and performance characteristics * Fuse holders and blocks - with the requisite terminations, mounting options and safety features To Find Out More: If you need a custom solution to a product problem, submit a Request for Quotation to your local authorized Cooper Bussmann distributor or sales representative. * Wire connection products - that make wiring simpler, safer and faster * Molded products - that give the unique shape your product needs * Power distribution products - that meet prevailing agency and Code requirements In-House Testing All electrical performance testing of your custom products can be performed at the Cooper Bussmann(R) Paul P. Gubany Center for High Power Technology, an ASTA and CSA accredited, and an ANCE Designated facility. We're able to conduct electrical performance testing that replicates any power system to be encountered in any country, covering: * Up to 300kA and 600Vac * Up to 100kA and 1000Vdc And our technicians conduct tests to many global agency standards including: * ANCE * ANSI * CE Services & Application Guide * CSA * ETL * IEC, and * Underwriters Laboratories For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 423 Application Guide Fuse Technology Circuit Protection The following is a basic introduction to overcurrent protection and fuse technology. In depth information on the selection and application of overcurrent protective devices is available in the Cooper Bussmann publication "Selecting Protective Devices" (SPD). This publication is available free of charge as a PDF download at www.cooperbussmann.com/spd. Electrical distribution systems are often quite complicated. They cannot be absolutely fail-safe. Circuits are subject to destructive overcurrents. Harsh environments, general deterioration, accidental damage, damage from natural causes, excessive expansion, and/or overloading of the electrical distribution system are factors which contribute to the occurrence of such overcurrents. Reliable protective devices prevent or minimize costly damage to transformers, conductors, motors, and the other many components and loads that make up the complete distribution system. Reliable circuit protection is essential to avoid the severe monetary losses which can result from power blackouts and prolonged downtime of facilities. It is the need for reliable protection, safety, and freedom from fire hazards that has made the fuse a widely used protective device. Overcurrents An overcurrent is either an overload current or a short-circuit current. The overload current is an excessive current relative to normal operating current, but one which is confined to the normal conductive paths provided by the conductors and other components and loads of the distribution system. As the name implies, a short-circuit current is one which flows outside the normal conducting paths. than the normal operating current. A high level fault may be 50,000A (or larger). If not cut off within a matter of a few thousandths of a second, damage and destruction can become rampant--there can be severe insulation damage, melting of conductors, vaporization of metal, ionization of gases, arcing, and fires. Simultaneously, high level short-circuit currents can develop huge magnetic-field stresses. The magnetic forces between bus bars and other conductors can be many hundreds of pounds per linear foot; even heavy bracing may not be adequate to keep them from being warped or distorted beyond repair. Fuses The fuse is a reliable overcurrent protective device. A "fusible" link or links encapsulated in a tube and connected to contact terminals comprise the fundamental elements of the basic fuse. Electrical resistance of the link is so low that it simply acts as a conductor. However, when destructive currents occur, the link very quickly melts and opens the circuit to protect conductors, and other circuit components and loads. Fuse characteristics are stable. Fuses do not require periodic maintenance or testing. Fuses have three unique performance characteristics: 1. Modern fuses have an extremely "high interrupting rating"--can withstand very high fault currents without rupturing. 2. Properly applied, fuses prevent "blackouts." Only the fuse nearest a fault opens without upstream fuses (feeders or mains) being affected--fuses thus provide "selective coordination." (These terms are precisely defined in subsequent pages.) 3. Fuses provide optimum component protection by keeping fault currents to a low value...They are said to be "current limiting." Overloads Voltage Rating Overloads are most often between one and six times the normal current level. Usually, they are caused by harmless temporary surge currents that occur when motors are started-up or transformers are energized. Such overload currents, or transients, are normal occurrences. Since they are of brief duration, any temperature rise is trivial and has no harmful effect on the circuit components. (It is important that protective devices do not react to them.) The voltage rating of a fuse must be at least equal to or greater than the circuit voltage. It can be higher but never lower. For instance, a 600V fuse can be used in a 208V circuit. Continuous overloads can result from defective motors (such as worn motor bearings), overloaded equipment, or too many loads on one circuit. Such sustained overloads are destructive and must be cut off by protective devices before they damage the distribution system or system loads. However, since they are of relatively low magnitude compared to short-circuit currents, removal of the overload current within minutes will generally prevent equipment damage. A sustained overload current results in overheating of conductors and other components and will cause deterioration of insulation, which may eventually result in severe damage and short-circuits if not interrupted. Short-Circuits Whereas overload currents occur at rather modest levels, the short-circuit or fault current can be many hundred times larger 424 The voltage rating of a fuse is a function of its capability to open a circuit under an overcurrent condition. Specifically, the voltage rating determines the ability of the fuse to suppress the internal arcing that occurs after a fuse link melts and an arc is produced. If a fuse is used with a voltage rating lower than the circuit voltage, arc suppression will be impaired and, under some fault current conditions, the fuse may not clear the overcurrent safely. Special consideration is necessary for semiconductor fuse and medium voltage fuse applications, where a fuse of a certain voltage rating is used on a lower voltage circuit. Amp Rating Every fuse has a specific amp rating. In selecting the amp rating of a fuse, consideration must be given to the type of load and code requirements. The amp rating of a fuse normally should not exceed the current carrying capacity of the circuit. For instance, if a conductor is rated to carry 20A, a 20A fuse is the largest that should be used. However, there are some specific circumstances in which the amp rating is permitted to be greater than the current carrying capacity of the circuit. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Application Guide Fuse Technology A typical example is the motor circuit; dual-element fuses generally are permitted to be sized up to 175% and non-timedelay fuses up to 300% of the motor full-load amps. As a rule, the amp rating of a fuse and switch combination should be selected at 125% of the continuous load current (this usually corresponds to the circuit capacity, which is also selected at 125% of the load current). There are exceptions, such as when the fuse-switch combination is approved for continuous operation at 100% of its rating. Interrupting Rating A protective device must be able to withstand the destructive energy of short-circuit currents. If a fault current exceeds the capability of the protective device, the device may actually rupture, causing additional damage. Thus, it is important when applying a fuse or circuit breaker to use one which can sustain the largest potential short-circuit currents. The rating which defines the capacity of a protective device to maintain its integrity when reacting to fault currents is termed its "interrupting rating". The interrupting rating of most branchcircuit, molded case, circuit breakers typically used in residential service entrance panels is 10,000A. (Please note that a molded case circuit breaker's interrupting capacity will typically be lower than its interrupting rating.) Larger, more expensive circuit breakers may have interrupting ratings of 14,000A or higher. In contrast, most modern, current-limiting fuses have an interrupting rating of 200,000 or 300,000A and are commonly used to protect the lower rated circuit breakers. The National Electrical Code, Section 110-9, requires equipment intended to break current at fault levels to have an interrupting rating sufficient for the current that must be interrupted. Selective Coordination - Prevention of Blackouts The coordination of protective devices prevents system power outages or blackouts caused by overcurrent conditions. When only the protective device nearest a faulted circuit opens and larger upstream fuses remain closed, the protective devices are "selectively" coordinated (they discriminate). The word "selective" is used to denote total coordination...isolation of a faulted circuit by the opening of only the localized protective device. KRP-C 1200SP LPS-RK 600SP LPS-RK 200SP 2:1 (or more) 2:1 (or more) This diagram shows the minimum ratios of amp ratings of Low-Peak Yellow fuses that are required to provide "selective coordination" (discrimination) of upstream and downstream fuses. Current Limitation - Component Protection Areas within waveform loops represent destructive energy impressed upon circuit components Normal load current Initiation of short-circuit current Circuit breaker trips and opens short-circuit in about 1 cycle A non-current-limiting protective device, by permitting a shortcircuit current to build up to its full value, can let an immense amount of destructive short-circuit heat energy through before opening the circuit. Fuse opens and clears short-circuit in less than TM cycle A current-limiting fuse has such a high speed of response that it cuts off a short-circuit long before it can build up to its full peak value. If a protective device cuts off a short-circuit current in less than one-quarter cycle, before it reaches its total available (and highly destructive) value, the device is a "current-limiting" device. Most modern fuses are current-limiting. They restrict fault currents to such low values that a high degree of protection is given to circuit components against even very high short-circuit currents. They permit breakers with lower interrupting ratings to be used. They can reduce bracing of bus structures. They minimize the need of other components to have high short-circuit current "withstand" ratings. If not limited, short-circuit currents can reach levels of 30,000 or 40,000A or higher in the first half cycle (.008 seconds, 60Hz) after the start of a short-circuit. The heat that can be produced in circuit components by the immense energy of short-circuit currents can cause severe insulation damage or even explosion. At the same time, huge magnetic forces developed between conductors can crack insulators and distort and destroy bracing structures. Thus, it is important that a protective device limit fault currents before they reach their full potential level. Services & Application Guide Unlike electromechanical inertial devices (circuit breakers), it is a simple matter to selectively coordinate fuses of modern design. By maintaining a minimum ratio of fuse-amp ratings between an upstream and downstream fuse, selective coordination is assured. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 425 Application Guide Fuse Technology Operating Principles of Cooper Bussmann(R) Fuses The principles of operation of the modern, current-limiting fuses are covered in the following paragraphs. Non-Time-Delay Fuses The basic component of a fuse is the link. Depending upon the amp rating of the fuse, the single-element fuse may have one or more links. They are electrically connected to the end blades (or ferrules) (see Figure 1) and enclosed in a tube or cartridge surrounded by an arc quenching filler material. Cooper Bussmann(R) Limitron(R) and T-Tron(R) fuses are both single-element fuses. Under normal operation, when the fuse is operating at or near its amp rating, it simply functions as a conductor. However, as illustrated in Figure 2, if an overload current occurs and persists for more than a short interval of time, the temperature of the link eventually reaches a level which causes a restricted segment of the link to melt. As a result, a gap is formed and an electric arc established. However, as the arc causes the link metal to burn back, the gap becomes progressively larger. Electrical resistance of the arc eventually reaches such a high level that the arc cannot be sustained and is extinguished. The fuse will have then completely cut off all current flow in the circuit. Suppression or quenching of the arc is accelerated by the filler material. (See Figure 3.) Single-element fuses of present day design have a very high speed of response to overcurrents. They provide excellent short-circuit component protection. However, temporary, harmless overloads or surge currents may cause nuisance openings unless these fuses are oversized. They are best used, therefore, in circuits not subject to heavy transient surge currents and the temporary over-load of circuits with inductive loads such as motors, transformers, solenoids, etc. Because single-element, fast-acting fuses such as Limitron and T-Tron fuses have a high speed of response to short-circuit currents, they are particularly suited for the protection of circuit breakers with low interrupting ratings. Whereas an overload current normally falls between one and six times normal current, short-circuit currents are quite high. The fuse may be subjected to short-circuit currents of 30,000 or 40kA or higher. Response of current limiting fuses to such currents is extremely fast. The restricted sections of the fuse link will simultaneously melt (within a matter of two or threethousandths of a second in the event of a high-level fault current). The high total resistance of the multiple arcs, together with the quenching effects of the filler particles, results in rapid arc suppression and clearing of the circuit. (Refer to Figures 4 & 5) Short-circuit current is cut off in less than a half-cycle, long before the short-circuit current can reach its full value (fuse operating in its current limiting range). 426 Figure 1. Cutaway view of typical single-element fuse. Figure 2. Under sustained overload, a section of the link melts and an arc is established. Figure 3. The "open" single-element fuse after opening a circuit overload. Figure 4. When subjected to a short-circuit current, several sections of the fuse link melt almost instantly. Figure 5. The "open" single-element fuse after opening a short circuit. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Application Guide Fuse Technology Cooper Bussmann(R) Dual-Element Fuses There are many advantages to using these fuses. Unlike single-element fuses, the Cooper Bussmann(R) dual-element, time-delay fuses can be sized closer to provide both high performance short-circuit protection and reliable overload protection in circuits subject to temporary overloads and surge currents. For ac motor loads, a single-element fuse may need to be sized at 300% of an a.c. motor current in order to hold the starting current. However, dual-element, time delay fuses can be sized much closer to motor loads. For instance, it is generally possible to size Fusetron Dual-Element Fuses, FRS-R and FRN-R and Low-Peak(R) Dual-Element Fuses, LPS-RK_SP and LPN-RK_SP, at 125% and 130% of motor full load current, respectively. Generally, the Low-Peak Dual-Element Fuses, LPJ_SP, and CUBEFuse(R), TCF, can be sized at 150% of motor full load amps. This closer fuse sizing may provide many advantages such as: (1) smaller fuse and block, holder or disconnect amp rating and physical size, (2) lower cost due to lower amp rated devices and possibly smaller required panel space, (3) better short-circuit protection - less short-circuit current let-through energy, and (4) potential reduction in the arc-flash hazard. Insulated end-caps to help prevent accidental contact with live parts. Filler material Figure 6. Short-circuit element Small volume of metal to vaporize Overload element Figure 9. Figure 7. M M Before Filler quenches the arcs Spring After Figure 8. Figure 10. M Overcurrent protection must be reliable and sure. Whether it is the first day of the electrical system or thirty or more years later, it is important that overcurrent protective devices perform under overload or short-circuit conditions as intended. Modern current-limiting fuses operate by very simple, reliable principles. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 427 Services & Application Guide When the short-circuit current is in the current-limiting range of a fuse, it is not possible for the full available short-circuit current to flow through the fuse - it's a matter of physics. The small restricted portions of the short-circuit element quickly vaporize and the filler material assists in forcing the current to zero. The fuse is able to "limit" the short-circuit current. Application Guide Fuse Technology Fuse Time-Current Curves When a low level overcurrent occurs, a long interval of time will be required for a fuse to open (melt) and clear the fault. On the other hand, if the overcurrent is large, the fuse will open very quickly. The opening time is a function of the magnitude of the level of overcurrent. Overcurrent levels and the corresponding intervals of opening times are logarithmically plotted in graph form as shown to the right. Levels of overcurrent are scaled on the horizontal axis; time intervals on the vertical axis. The curve is thus called a "time-current" curve. 400 300 This particular plot reflects the characteristics of a 200A, 250V, Low-Peak(R) dual-element fuse. Note that at the 1,000A overload level, the time interval which is required for the fuse to open is 10 seconds. Yet, at approximately the 2,200A overcurrent level, the opening (melt) time of a fuse is only 0.01 seconds. It is apparent that the time intervals become shorter as the overcurrent levels become larger. This relationship is termed an inverse time-to-current characteristic. Time-current curves are published or are available on most commonly used fuses showing "minimum melt," "average melt" and/or "total clear" characteristics. Although upstream and downstream fuses are easily coordinated by adhering to simple amp ratios, these time-current curves permit close or critical analysis of coordination. 40 30 The derating of dual-element fuses based on increased ambient temperatures closely parallels the derating curve of motors in elevated ambient. This unique feature allows for optimum protection of motors, even in high temperatures. Affect of ambient temperature on operating characteristics of Fusetron and Low-Peak dual-element fuses. 150 10 8 6 4 3 2 1 .8 .6 .4 .3 .2 110 .04 100 .03 90 60 30 -76F -40F -4F (-60C) (-40C) (-20C) -32F (0C) 68F (20C) 104F (40C) 140F (60C) 176F (80C) 212F (100C) CURRENT IN AMPS AMBIENT 428 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 6,000 8,000 10,000 3,000 4,000 2,000 40 600 800 1,000 .01 50 300 400 70 .02 Affect on Opening Time 200 80 100 PERCENT OF RATING OR OPENING TIME Affect on Carrying Capacity Rating 120 20 .1 .08 .06 140 130 LOW-PEAK LPN-RK200 SP (RK1) 100 80 60 TIME IN SECONDS Better Motor Protection in Elevated Ambients 200 Application Guide Fuse Technology Better Protection Against Motor Single Phasing When secondary single-phasing occurs, the current in the remaining phases increases to approximately 200% rated full load current. (Theoretically 173%, but change in efficiency and power factor make it about 200%.) When primary singlephasing occurs, unbalanced voltages occur on the motor circuit causing currents to rise to 115%, and 230% of normal running currents in delta-wye systems. Dual-element fuses sized for motor running overload protection will help to protect motors against the possible damages of single-phasing. Classes of Fuses Safety is the industry mandate. However, proper selection, overall functional performance and reliability of a product are factors which are not within the basic scope of listing agency activities. In order to develop its safety test procedures, listing agencies develop basic performance and physical specifications or standards for a product. In the case of fuses, these standards have culminated in the establishment of distinct classes of low-voltage (600V or less) fuses; Classes RK1, RK5, G, L, T, J, H and CC being the more important. The fact that a particular type of fuse has, for instance, a classification of RK1, does not signify that it has the identical function or performance characteristics as other RK1 fuses. In fact, the Limitron(R) non-time-delay fuse and the Low-Peak dual-element, time-delay fuse are both classified as RK1. Substantial differences in these two RK1 fuses usually requires considerable difference in sizing. Dimensional specifications of each class of fuse does serve as a uniform standard. In the above illustration, a grooved ring in one ferrule provides the rejection feature of the Class R fuse in contrast to the lower interrupting rating, non-rejection type. Branch-Circuit Listed Fuses Branch-circuit listed fuses are designed to prevent the installation of fuses that cannot provide a comparable level of protection to equipment. The characteristics of Branch-circuit fuses are: 1. They must have a minimum interrupting rating of 10kA 2. They must have a minimum voltage rating of 125V. 3. They must be size rejecting such that a fuse of a lower voltage rating cannot be installed in the circuit. 4. They must be size rejecting such that a fuse with a current rating higher than the fuse holder rating cannot be installed. Class R Fuses For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Services & Application Guide Class R ("R" for rejection) fuses are high performance,110 to 600A units, 250V and 600V, having a high degree of current limitation and a short-circuit interrupting rating of up to 300kA (RMS Sym.). Cooper Bussmann(R) Class R fuses include Class RK1 Low-Peak(R) and Limitron(R) fuses, and RK5 Fusetron fuses. They have replaced the K1 Low-Peak and Limitron fuses and K5 Fusetron fuses. These fuses are identical, with the exception of a modification in the mounting configuration called a "rejection feature." This feature permits Class R fuses to be mounted in rejection type fuseclips. "R" type fuseclips prevent older type Class H, ONE-TIME and RENEWABLE fuses from being installed. The use of Class R fuse holders is thus an important safeguard. The application of Class R fuses in such equipment as disconnect switches permits the equipment to have a high interrupting rating. NEC(R) Articles 110-9 and 230-65 require that protective devices have adequate capacity to interrupt short-circuit currents. Article 240-60(b) requires fuse holders for current-limiting fuses to reject non-current-limiting type fuses. 429 Application Guide Fuse Technology Supplementary Overcurrent Protective Devices for use in Motor Control Circuits Branch Circuit vs. Supplemental Overcurrent Protective Devices Branch circuit overcurrent protective devices (OCPD) can be used everywhere OCPD are used, from protection of motors and motor circuits and group motor circuits, to protection of distribution and utilization equipment. Supplemental OCPD can only be used where proper protection is already being provided by a branch circuit device, by exception [i.e., 430.72(A)], or if protection is not required. Supplemental OCPD can often be used to protect motor control circuits but they cannot be used to protect motors or motor circuits. A very common misapplication is the use of a supplementary overcurrent protective device such as a UL 1077 mechanical overcurrent device for motor branch circuit short-circuit and ground fault protection. Supplementary OCPDs are incomplete in testing compared to devices that are evaluated for branch circuit protection. THIS IS A SERIOUS MISAPPLICATION AND SAFETY CONCERN!! Caution should be taken to assure that the proper overcurrent protective device is being used for the application at hand. Below is a description of popular supplementary overcurrent protective devices. Most supplemental overcurrent protective devices have very low interrupting ratings. Just as any other overcurrent protective device, supplemental OCPDs must have an interrupting rating equal to or greater than the available short-circuit current. Reliability and Maintenance of Overcurrent Protective Devices Modern fuses have several significant advantages over mechanical overcurrent protective devices - one of those advantages is reliability. Whether the first day of the electrical system or years later, it is important that overcurrent protective devices perform under overload and fault conditions as intended. Modern current-limiting fuses operate by very simple, reliable principles. Fuses do not have to be maintained. By their inherent design, fuses do not have elements or mechanisms to calibrate, adjust or lubricate. If and when fuses are called upon to open on an overcurrent, installing the same type and ampere rated fuses provides the circuit with new factorycalibrated protection. The original design integrity can be maintained throughout the life of the electrical system. One last point on fuse systems; the terminations, clips and disconnects should be maintained as necessary. In contrast, circuit breakers are mechanical devices, even those with electronic sensing, and circuit breakers require periodic maintenance, testing, and if necessary reconditioning or replacement. This is required per the circuit breaker manufacturers' instructions, NFPA 70B Recommended Practice for Electrical Equipment Maintenance, and NEMA AB4. If circuit breakers are not properly maintained, the interrupting rating, circuit component protection, coordination, and electrical safety may be compromised. See www.cooperbussmann.com for more information on Reliability and Maintenance. Supplemental fuses as listed or recognized to the UL/CSA/ANCE Trinational 248-14 Standard These are fuses that can have many voltages and interrupting ratings within the same case size. Examples of supplemental fuses are 1332'' X 1 12'', 5 x 20mm, and 14'' x 1 14'' fuses. Interrupting ratings range from 35 to 100,000 amps. 430 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Application Guide Motor Circuit Branch Circuit Protection Motor Circuits - Choice of Overcurrent Protection Motor circuits have unique characteristics and several functions, such as short-circuit protection, overload protection and automatic/ remote start/stop, that may be required. Sometimes the comment is made that users prefer circuit breakers because they can be reset. Let's examine the choice of either circuit breakers or current- limiting fuses for motor branch circuit protection. In the case to be examined, fuses and circuit breakers (includes magnetic only circuit breakers which are called MCPs or motor circuit protectors) are sized with the intent to provide only short-circuit and ground fault protection for the motor branch circuit protection per 430.52. Other means, such as overload relays, provide the motor overload protection. Typical thermal magnetic circuit breakers can only be sized for motor branch circuit protection (typically 200% - 250% of motor current) because if they are sized closer, the motor starting current trips the circuit breaker's instantaneous mechanism. Magnetic only circuit breakers (MCPs) are intentionally not provided with overload capability; they only operate on short-circuit currents. There are some fuses such as the FRS-R and LPS-RK fuses that can be sized close enough for motor running overload protection or backup motor running protection. But for the discussion in this section, assume current-limiting fuses are sized only for motor short-circuit and ground fault protection. It is important to note that in this protection level being discussed, a circuit breaker or fuses should only open if there is a fault on the motor circuit. A separate overload protective device, such as an overload relays, provides motor overload protection per 430.32. Here are some important considerations: 1. OSHA regulation 1910.334(b)(2) Use of Equipment states: Reclosing circuits after protective device operation. After a circuit is deenergized by a circuit protective device, the circuit may not be manually reenergized until it has been determined that the equipment and circuit can be safely energized. The repetitive manual reclosing of circuit breakers or reenergizing circuits through replaced fuses is prohibited. NOTE: When it can be determined from the design of the circuit and the over-current devices involved that the automatic operation of a device was caused by an overload rather than a fault condition, no examination of the circuit or connected equipment is needed before the circuit is reenergized. So the speed of reclosing a circuit breaker after a fault is not an advantage. The law requires that if the condition is a fault (that is the only reason the circuit breaker or fuses should open on a motor circuit), then the fault must be corrected prior to replacing fuses or resetting the circuit breaker. Consequently, with circuit breaker protection, after a fault condition, 3. Circuit breakers must be periodically tested to verify they mechanical operate and electrically tested to verify they still are properly calibrated within specification. The circuit breaker manufacturers recommend this. Typically circuit breakers should be mechanically operated at least every year and electrically tested every 1 to 5 years, depending on the service conditions. Modern current-limiting fuses do not have to be maintained or electrically tested to verify they still will operate as intended. The terminations of both circuit breakers and fusible devices need to be periodically checked and maintained to prevent thermal damage. Plus fuse clips should be periodically inspected and if necessary maintained. 4. After a circuit breaker interrupts a fault, it may not be suitable for further service. UL 489, the product standard for molded case circuit breakers, only requires a circuit breaker to interrupt two short-circuit currents at its interrupting rating. Circuit breakers that are rated 100 amps or less do not have to operate after only one short-circuit operation under "bus bar" short-circuit conditions. If the fault current is high, circuit breaker manufacturers recommend that a circuit breaker should receive a thorough inspection with replacement, if necessary. How does one know a circuit breaker's service history or what level of fault current that a circuit breaker interrupts? With modern current-limiting fuses, if the fuse interrupts a fault, new factory calibrated fuses are installed in the circuit. The original level of superior short-circuit protection can be there for the life of the motor circuit. 5. After a fault, the electrician has to walk back to the storeroom to get new fuses; that is if spare fuses are not stored adjacent to the equipment. This does require some additional down time. However, if fuses opened under fault conditions, there is a fault condition that must be remedied. The electrician probably will be going back to the storeroom anyway for parts to repair the fault. If properly selected current-limiting fuses are used in the original circuit, the starter will not sustain any significant damage or loss of overload calibration. With circuit breaker protection on motor circuits, after a fault condition, it may be necessary to repair or replace the starter, so a trip to the storeroom may be necessary. And if the starter is not significantly damaged, it may still need to be tested to insure the let-through energy by the circuit breaker has not caused the loss of starter overload calibration. Also, the circuit breaker needs to be evaluated for suitability before placing it back into service. Who is qualified for that evaluation? How much time will that take? In summary, resettability is not an important feature for motor branch circuit (short-circuit) protection and resettability of the branch circuit protective device is not a benefit for motor circuits. As a matter of fact, resettability of the motor branch circuit overcurrent protective device may encourage an unsafe practice. The function of motor branch circuit protection is fault protection: short-circuit and ground fault protection. Faults do not occur on a regular basis. But when a fault does occur, it is important to have the very best protection. The best motor branch circuit protection can be judged by (1) reliability - its ability to retain its calibration and speed of operation over its lifetime, (2) current-limiting protection - its ability to provide Type 2 "No Damage" protection to the motor starter, and (3) safety - its ability to meet a facility's safety needs. Modern current-limiting fuses are superior to circuit breakers for motor branch circuit protection. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 431 Services & Application Guide 2. The typical level of short-circuit protection for the motor starter provided by circuit breakers and MCPs is referred to as Type 1. This is because most circuit breakers are not current-limiting. So, for a loadside fault, the starter may sustain significant damage such as severe welding of contacts and rupturing of the heater elements. Or the heater/overload relay system may lose calibration. This is an acceptable level of performance per UL 508, which is the product standard for motor starters. Current-limiting fuses can be selected that can provide Type 2 "No Damage" short-circuit protection for motor starters. significant downtime and cost may be incurred in repairing or replacing the starter. With properly selected fuses for Type 2 protection, after the fault is repaired, only new fuses need to be inserted in the circuit; the starter does not have to be repaired or replaced. Application Guide Glossary Ampere (Amp) Class G Fuses Class R Fuses The measurement of intensity of rate of flow of electrons in an electric circuit. An ampere (amp) is the amount of current that will flow through a resistance of one ohm under a pressure of one volt. Ampere is often abbreviated as "A". 480V, 100kA interrupting rating branch circuit fuses that are size rejecting to eliminate overfusing. The fuse diameter is 1332" while the length varies from 1516" to 214". These are available in ratings from 1A through 60A. Amp Rating Class H Fuses The current-carrying capacity of a fuse. When a fuse is subjected to a current above its amp rating, it will open the circuit after a predetermined period of time. 250V and 600V, 10kA interrupting rating branch circuit fuses that may be renewable or non-renewable. These are available in amp ratings of 1A through 600A. These are high performance fuses rated 1 10-600A in 250V and 600V ratings. All are marked "Current Limiting" on their label and all have a minimum of 200kA interrupting rating. They have identical outline dimensions with the Class H fuses but have a rejection feature which prevents the user from mounting a fuse of lesser capabilities (lower interrupting capacity) when used with special Class R Clips. Class R fuses will fit into either rejection or non-rejection clips. Amp Squared Seconds, l2t Class J Fuses The measure of heat energy developed within a circuit during the fuse's clearing. It can be expressed as "melting l2t", "arcing l2t" or the sum of them as "Clearing l2t". "l" stands for effective let-through current (RMS), which is squared, and "t" stands for time of opening, in seconds. These fuses are rated to interrupt a minimum of 200kA AC. They are labeled as "Current-Limiting", are rated for 600Vac, and are not interchangeable with other classes. Class K Fuses Class T Fuses An industry class of fuses in 300V and 600V ratings from 1A through 1200A. They are physically very small and can be applied where space is at a premium. They are fast acting fuses with an interrupting rating of 200kA RMS. Classes of Fuses The amount of time from the instant the fuse link has melted until the overcurrent is interrupted, or cleared. These are fuses listed as K-1, K-5, or K-9 fuses. Each subclass has designated I2t and lp maximums. These are dimensionally the same as Class H fuses, and they can have interrupting ratings of 50k, 100k, or 200kA. These fuses are current-limiting. However, they are not marked "current-limiting" on their label since they do not have a rejection feature. Breaking Capacity Class L Fuses Clearing Time (See Interrupting Rating) These fuses are rated for 601 through 6000A, and are rated to interrupt a minimum of 200kA AC. They are labeled "Current-Limiting" and are rated for 600Vac. They are intended to be bolted into their mountings and are not normally used in clips. Some Class L fuses have designed in time-delay features for all purpose use. The total time between the beginning of the overcurrent and the final opening of the circuit at rated voltage by an overcurrent protective device. Clearing time is the total of the melting time and the arcing time. Arcing I2t Value of the I2t during the arcing time under specified conditions. Arcing Time Cartridge Fuse A fuse consisting of a current responsive element inside a fuse tube with terminals on both ends. Class CC Fuses 600V, 200kA interrupting rating, branch circuit fuses with overall dimensions of 13 32" x 112". Their design incorporates a rejection feature that allows them to be inserted into rejection fuse holders and fuse blocks that reject all lower voltage, lower interrupting rating 1332" x 112" fuses. They are available from 110A through 30A. 432 The industry has developed basic physical specifications and electrical performance requirements for fuses with voltage ratings of 600V or less. These are known as standards. If a type of fuse meets the requirements of a standard, it can fall into that class. Typical classes are K, RK1, RK5, G, L, H, T, CC, and J. Current Limitation A fuse operation relating to short circuits only. When a fuse operates in its current-limiting range, it will clear a short circuit in less than 12 cycle. Also, it will limit the instantaneous peak let-through current to a value substantially less than that obtainable in the same circuit if that fuse were replaced with a solid conductor of equal impedance. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Application Guide Glossary Dual Element Fuse Melting I2t Peak Let-Through Current, lp Fuse with a special design that utilizes two individual elements in series inside the fuse tube. One element, the spring actuated trigger assembly, operates on overloads up to 5-6 times the fuse current rating. The other element, the short circuit section, operates on short circuits up to their interrupting rating. Value of the I2t during the melting time of the fuse link under specified conditions. The instantaneous value of peak current let-through by a current-limiting fuse, when it operates in its current-limiting range. Electrical Load "NEC(R)" Dimensions That part of the electrical system which actually uses the energy or does the work required. These are dimensions once referenced in the National Electrical Code. They are common to Class H and K fuses and provide interchangeability between manufacturers for fuses and fusible equipment of given ampere and voltage ratings. Fast-Acting Fuse A fuse which opens on overload and short circuits very quickly. This type of fuse is not designed to withstand temporary overload currents associated with some electrical loads. Fuse An overcurrent protective device with a fusible link that operates and opens the circuit on an overcurrent condition. High Speed Fuses Fuses with no intentional time-delay in the overload range and designed to open as quickly as possible in the short-circuit range. These fuses are often used to protect solid-state devices. Inductive Load An electrical load which pulls a large amount of current--an inrush current-- when first energized. After a few cycles or seconds the current "settles down" to the full-load running current. Melting Time The amount of time required to melt the fuse link during a specified overcurrent. (See Arcing Time and Clearing Time.) Resistive Load An electrical load which is characteristic of not having any significant inrush current. When a resistive load is energized, the current rises instantly to its steady-state value, without first rising to a higher value. RMS Current The unit of measure for electric resistance. An ohm is the amount of resistance that will allow one ampere to flow under a pressure of one volt. The RMS (root-mean-square) value of any periodic current is equal to the value of the direct current which, flowing through a resistance, produces the same heating effect in the resistance as the periodic current does. Ohm's Law The relationship between voltage, current, and resistance, expressed by the equation E = IR, where E is the voltage in volts, I is the current in amps, and R is the resistance in ohms. One Time Fuses Generic term used to describe a Class H non-renewable cartridge fuse, with a single element. Overcurrent Interrupting Rating -- IR Overload (Breaking Capacity) Can be classified as an overcurrent which exceeds the normal full load current of a circuit. Also characteristic of this type of overcurrent is that it does not leave the normal current carrying path of the circuit--that is, it flows from the source, through the conductors, through the load, back through the conductors, to the source again. SCCR See Short-Circuit Current Rating Semiconductor Fuses Fuses used to protect solid-state devices. See "High Speed Fuses." Short-Circuit Can be classified as an overcurrent which exceeds the normal full load current of a circuit by a factor many times (tens, hundreds or thousands greater). Also characteristic of this type of overcurrent is that it leaves the normal current carrying path of the circuit--it takes a "short cut" around the load and back to the source. Short-Circuit Current Rating (SCCR) The maximum short-circuit current an electrical component can sustain without the occurrence of excessive damage when protected with an overcurrent protective device. Short-Circuit Withstand Rating Same definition as short-circuit rating. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 433 Services & Application Guide (See Interrupting Rating) The rating which defines a fuse's ability to safely interrupt and clear short circuits. This rating is much greater than the ampere rating of a fuse. The NEC(R) defines Interrupting Rating as "The highest current at rated voltage that an overcurrent protective device is intended to interrupt under standard test conditions." A fuse in which the element, typically a zinc link, may be replaced after the fuse has opened, and then reused. Renewable fuses are made to Class H standards. Ohm A condition which exists on an electrical circuit when the normal load current is exceeded. Overcurrents take on two separate characteristics--overloads and short circuits. Interrupting Capacity Renewable Fuse (600V & below) Application Guide Glossary Single-Phasing That condition which occurs when onephase of a three-phase system opens, either in a low voltage (secondary) or high voltage (primary) distribution system. Primary or secondary singlephasing can be caused by any number of events. This condition results in unbalanced currents in polyphase motors and unless protective measures are taken, causes overheating and failure. Threshold Current The symmetrical RMS available current at the threshold of the current-limiting range, where the fuse becomes current-limiting when tested to the industry standard. This value can be read off of a peak let-through chart where the fuse curve intersects the A-B line. A threshold ratio is the relationship of the threshold current to the fuse's continuous current rating. Time-Delay Fuse A fuse with a built-in delay that allows temporary and harmless inrush currents to pass without opening, but is so designed to open on sustained overloads and short circuits. Out-of-Stock Substitution/Upgrades Cooper Bussmann # AGC-(AMP) Upgrade # ABC-(AMP) Description FAST-ACTING, 14" X 114" FUSE AGC-V-(AMP) ABC-V-(AMP) FAST-ACTING, 14" X 114" FUSE WITH LEADS 2001 AGU-(AMP) LP-CC-(AMP) FAST-ACTING, 1332" X 112" FUSE 2008 BAF-(AMP) LP-CC-(AMP) FAST-ACTING, 1332" X 112" FUSE 2011 BAN-(AMP) LP-CC-(AMP) FAST-ACTING, 1332" X 112" FUSE 2046 FNM-(AMP) LP-CC-(AMP) TIME-DELAY, 1332" X 112" FUSE 2028 FNQ-R-(AMP) LP-CC-(AMP)* TIME-DELAY, 500V, 1332" X 112" FUSE 1012 FNR-R-(AMP) LPN-RK-(AMP)SP TIME-DELAY, 250V, CLASS RK5 FUSES 1019/1020 FRS-R-(AMP) LPS-RK-(AMP)SP TIME-DELAY, 600V, CLASS RK5 FUSES 1017/1018 JKS-(AMP) LPJ-(AMP)SP FAST-ACTING, 600V, CLASS J FUSE 1026/1027 1013 KLU-(AMP) KRP-C-(AMP)SP TIME-DELAY, CLASS L FUSE KTK-(AMP) KTK-R-(AMP) FAST-ACTING, 600V, 1332" X 112" FUSE 1011 KTK-R-(AMP) LP-CC-(AMP) FAST-ACTING, 600V, CLASS CC FUSE 1015 KTN-R-(AMP) LPN-RK-(AMP)SP FAST-ACTING, 250V, CLASS RK1 FUSE 1043 KTS-R-(AMP) LPS-RK-(AMP)SP FAST-ACTING, 600V, CLASS RK1 FUSE 1044 KTU-(AMP) KPR-C-(AMP)SP FAST-ACTING, 600V, CLASS L FUSE 1010 MDL-(AMP) MDA-(AMP) TIME-DELAY, 14" X 114" FUSE 2004 MDL-V-(AMP) MDA-V-(AMP) TIME-DELAY, 14" X 114" FUSE WITH LEADS 2004 MTH-(AMP) ABC-(AMP) FAST-ACTING, 14" X 114" FUSE NON-(AMP) LPN-RK-(AMP)SP GENERAL PURPOSE, 250V, CLASS H FUSES 1030 NOS-(AMP) LPS-RK-(AMP)SP GENERAL PURPOSE, 600V, CLASS H FUSES 1030 REN-(AMP) LPN-RK-(AMP)SP 250V RENEWABLE FUSELINK 1028 RES-(AMP) LPS-RK-(AMP)SP 600V RENEWABLE FUSELINK 1028 1033 SL-(AMP) S-(AMP) TIME-DELAY, 125V, PLUG FUSE TL-(AMP) T-(AMP) TIME-DELAY, 125V, PLUG FUSE 1035 W-(AMP) TL-(AMP) TIME-DELAY, 125V, PLUG FUSE 1035 *Not recommended for control transformer circuits. Total Clearing I2t Total measure of heat energy developed within a circuit during the fuse's clearing of a fault current. Total Clearing I2t is the sum of the melting I2t and arcing I2t. Voltage Rating The maximum open circuit voltage in which a fuse can be used, yet safely interrupt an overcurrent. Exceeding the voltage rating of a fuse impairs its ability to clear an overload or short circuit safely. Withstand Rating The maximum current that an unprotected electrical component can sustain for a specified period of time without the occurrence of extensive damage. 434 Data Sheet # 2001 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Application Guide Industrial Fuse Applications Industrial Applications 1. Interior Lighting 2. Computer Power 3. Switchboards 4. Motor Control Center 5. Emergency Lighting 6. UPS Backup Power Supplies 7. Transformer/Emergency Generator 8. Forklift Battery Charging Station 9. HVAC Chillers/Blowers 10. Welding Circuits 11. Plant Lighting 12. Distribution Panels 13. Disconnect Switches 14. Programmable Logic Circuits 15. Conveyor System 1 2 3 8 7 5 6 4 9 12 10 11 13 15 14 Commercial Applications 1 3 2 5 4 7 6 8 9 10 11 1. Interior Lighting 2. HVAC Blowers 3. Computer Power 4. Branch Circuits 5. Emergency Lighting 6. Load Centers 7. Disconnect/Distribution Panels 8. HVAC/Chillers 9. Switchboards/Motor Control Centers 10. UPS Backup Power Supplies 11. Elevator Control Centers 12. Transformer/Emergency Generator 12 Services & Application Guide 435 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 435 Index Catalog Number Index Catalog Number Page 1025 * 11 Type 400 11239 275 11240 275 11241 275 11242 275 11675299 11725299 11960 * 13195 * 13926 * 14002301 14004301 15087 398 15100 394 15149 329 15188308 15200 394 15242 * 15288308 15506 * 15515 * 15595 * 15600 * 15602 * 15660 * 15800 392 15900 * 15968 * 160___ 299, 300 162___ 299, 300 162__-_UL * 163__ 297-298, 299-300 163__-_UL * 164___ * 165___ 299, 300 1683A75H08 * 170E_ _ _ _ 173-177, 180-184 170F_ _ _ _ 178-179 170H_ _ _ _ 185-186 170L * 170M_ _ _ _ 117-172 170N * 170R * 170T * 171A * 17415 * 175GDMSJD * 175GXQNJD * 1768A40H * 19315 * 19320 * 1976 * 1A0065 91 1A0835 * 1A111968 1A112068 1A1310 * 1A1360 * 1A1478 * 1A1837 * 1A1838 * 1A1853 * 1A190768 Catalog Number 1A2294 1A2650 1A33981A33991A34001A3746 1A45331A45341A4544 1A4708 1A4806 1A50181A5041 1A5220 1A56001A56011A56021A5603 1A5778 1A5779 1A5780 1A5940 1A6004 1A6049 1A8654 1A9619 1B0021 1B0048 1B0049 1B0089 1BR021 1BR048 1BS1_ _ _ 1CIF 2004 2081 20BS 20LSC 21010 21040 21050 21065 21100 21200 2127 2177 2178 2201 2245 2322 24 Type 2429 2430 2432 246B9949BG 2487 2494 2499 25499 2601 2602 2604 2605 2607 Page * * 68 67 69 * 68 68 * * * 67 * * 69 67 67 * 69 69 69 * * * * * * * * 271 * * 113, 186 * * * 235 235 * * * * * * * * * * * * 400 * * * * * * 288 * * * * * * Catalog Number 2608 2610 2611 2650 2654 2698 270303 2714 2772 2778 2795 2833 2834 2837 2838 2839 2860 2960 2989 2992 2A066 2A1279 2A8 30LSC 323A2433P6 32BS 3356 3373 3375 3411 3429 3434 3512 3513 3515 3519 3520 3521 3525 3528 3531 353837 3544 3545 3552 3553 3554 3555 3556 3562 3569 3571 3572 3575 3576 3578 3580 3591 3594 3595 3604 3723 3742 3743 Page * * * * * * 91 * * * * * * * * * * * * * * 295 * 235 * 235 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 290 290 290 Catalog Number 3794 3823 3828 3833 3835 3839 3959 3998 39E 4070 4121 4164 4178 4180 4202 4207 4261 4287 4386 4393 4399 4402 4405 4406 4407 4408 4410 4411 4412 4413 4415 4421 4422 4423 4427 4428 4467 4482 4483 4512 4513 4514 4515 4520 4522 4525 4528 4529 4530 4532 4534 4535 4537 4561 4567 4574 4586 4648 4909 510 51215 51235 558730 5591- Page * * 289 * 290 * * * * * * 52 * * * * * * * 289 * * 288 288 * * * * * * * 290 * * * * * * * * * * 290 289 * * * * * * * * * * * 288 * * * * * * * 70 Catalog Number 55925623 567256745678 568156825950 59565958 59605961 5TPH 60/100BS 60/100LSC 6125 6125TD 6374 63A-DUMMY 64 _ _ _ 6415 6417 6418 6419 6420 64200 6422 6424 6427 64913 64926 6525-25-0341 65372 65398 6725 675 68_ _ _ 68100 7 Type 70 Series 7071-0192 72 74 Type 75 Type 76 Type 80 Type 80910 81 Type 82048 8414677 84345 8456A85H 847966108 8583A36H 8588A81H 88914568 9078A67G04 9435 9483 9732 9789 9834 9835 Page 70 * 70 70 * 70 70 * 70 * 70 * 414 235 235 * * * * 46 * * * * * * * * * * * * * * * * 46 * 400 398 398 * * 400 401 401 401 * 401 * * * * * * * * 91 * * * * * * * Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Call 636-527-3877. 436 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 436 Index Catalog Number Index Catalog Number * * * * 91 * 91 91 * 225 63 85 63 85 85 * * 79, 85 226 * * * * * * 226 * 81 79 84 * * * 62 62 63 63 * * 62 62 * * 258 * * * * 79, 85 52 52 * * 55 55 55 * 55 55 55 247 247 * * Catalog Number B83 B84 B93 BAF BAN BAO BBS BBU BBU-EFID BC (fuse blocks) BC (fuses) BCA603 BCBC BCBD BCBS BCC BCCM BCF BD (fuses) BD (switches) BDF BDFLNF100 BDFLNF175 BDFLNF200 BDFLNF30 BDFLNF400 BDFLNF60 BDFLNF600 BDNF1200 BDNF1600 BDNF2000 BDNF3150 BDNF600 BDNF800 BFW BG BGH BH- _ _ _ _ 113, BH-_ xxx BM BMA603 BNQ21-WH BP655 BQE BQQ41-WH BRT BRW C08G C08M C08NL C10G C10M C10NL C14G C14G_S C14M C14M_S C14NL C19 C22G C22G_S C22M C22M_S C22NL Page * * * 47 * 225 50 89-90 * 274 226 273 245-246 245-246 245-246 * 274 * 226 244 * 369-370 369 369-370 369-370 369 369-370 369 367-368 367-368 367-368 367-368 365-366 365-366 * 274 * 225, 275 113, 186 274 273 311 * 311 311 * * 232 233 258 232 233 * 232 234 233 234 258 * 232 234 233 234 258 Catalog Number C2617 C2791 C2909 C30BS C30F C30FBS C4044 C4534 C4559 C515 C517 C518 C519 C520 C5237 C5268C5898 C60BS C60F C60FBS C6344 C7018 C7019 C7020 C7021C7024CAV CAVH CB203107S2105 CB3 CB5 CBB CBC CBF CBP CBPUB-ES-ED1H CBPUB-ES-ED2H CBPUB-ES-ED30H CBPUB-ES-ED31H CBPUB-ES-ED32H CBPUB-ES-ED33H CBPUB-ES-ED34H CBPUB-ES-ED35H CBPUB-ES-ED36H CBPUB-ES-ED3H CBS CBSV-ES-ED1 CBSV-ES-ED3 CBSV-ES-ED4 CBSV-ES-ED5 CBSV-ES-ED6 CBSV-ES-EN1 CBSV-ES-EN2 CBSV-ES-EN3 CBSV-ES-EN4 CBSV-ES-EN5 CBSV-ES-EN6 CBSV-ES-EN7 CBSV-ES-EN8 CBSV-ES-TEHP CBSV-ES-TELP CBSV-ES-TEMP CBSV-SC-EN8 CBT Page * * * 235 235 235 * * * 58 58 58 58 58 * 113 * 235 235 235 * * * * 403 404 79, 85 79, 85 * * * * * * * 421 421 421 421 421 421 421 421 421 421 * 421 421 421 421 421 418 418 418 418 418 418 418 418 422 422 422 419-420 * Catalog Number Page CBTR-ES-1DA 421 CBTR-ES-1HP 421 CBTR-ES-2HP 421 CBTR-SC-1HP 421 CBTR-SC-2HP 421 CBU * CCB * CCC * CCE * CCG * CCP326-329 CCSK-45 410 CD 226 CD1 * CD100 * CD27 * CD33 * CDB * CDC * CDN (fuses) 219 CDNF100 352-355, 356-358, 371 CDNF16 352-355, 356-358 CDNF160 359-360, 371 CDNF200 361-362, 371 CDNF25 352-355, 356-358 CDNF30 352-355, 356-358, 371 CDNF32 352-355, 356-358 CDNF400 363-364 CDNF45 352-355, 356-358 CDNF60 352-355, 356-358, 371 CDNF63 352-355, 356-358 CDS 219 CDS6 * CDS8 * CDS9 * CDSS 338 CEO 225 CFD100 334-336, 344-346 CFD200 337-339, 346 CFD30 331-333, 344-346 CFD60 334-336, 344-346 CFD600 346 CFD800 346 CFZ * CGL 220 CH30J_ 254 CH30J_I 254 CH60J_ 254 CH60J_I 254 CH08 258 CH10 * CH10CL * CH10CM * CH14 258 CH14-HP 258 CH14MS-_D 258 CH22 258 CH810-HP 258 CHCC 257 CHM 257 CH-PLC 258 CHPV 257 CIF 221 CIH 223 Catalog Number CIK CIL CJ CL1 CM__CF CM__F CM__FC CP14002 CPB16 _ CPDBCPS-C CT CUG _D125 _D16 _D27 _D33 DCM DD DEO DFC DFJ DIA DLN-R DLS-R DRA-1 DRA-2 DRLC-A E-6188 EBI055EC-_ _ _ ECF ECL055ECL155ED EDA EDN EET EF EFC30 EFC60 EFF EFH EFJ100 EFJ200 EFJ30 EFJ400 EFJ60 EFJ600 EFJ800 EFL800 EFS EK ELN EN6 ENA ENF100 ENF1200 ENF125 ENF16 ENF1600 ENF200 ENF2000 ENF25 Page 223 223 222 195 235 225 225 * 296, 299-300 296-297, 299-300 * 191-192 * 227 227 227 227 47 226 225 * 97 * 34 34 413 413 * * * 195 * 76 77 226 40 40 191-193 226 378-380 378, 380 * * 378-380 378-380 378-380 378-380 378-380 378-380 378-380 379-380 226 * * * * 381-383 381-383 381-383 381-383 381-383 381-383 381-383 381-383 * Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Call 636-527-3877. 437 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 437 Services & Application Guide 9838 9841 9843 A3354705 A3354710 A3354720 A3354730 A3354745 A404302 AAO ABC ABCNA ABC-V ABFNA ABGNA ABS ABU ABWNA AC ACB ACF ACH ACK ACL ACO AD ADL ADLSJ ADMNA ADOSJ AF AFS AFX AGA AGA-V AGC AGC-V AGS AGU AGW AGX AGX-V AGY AL-D ALS ALW AMG AMI AMWNA ANL ANN ASZ350B3 AT ATC ATC-_ID ATC-FHID ATF ATM ATM-_ID ATM-FHID B221 B222 B40 B48 Page Index Catalog Number Index Catalog Number ENF30 ENF3150 ENF32 ENF400 ENF45 ENF60 ENF600 ENF63 ENF800 ENN EP ERK-28 ERS2 ERS30 ESD ET ETF EVF F01A F02A F02B F03A F03B F06A F07A F09A F09B F10A F15A F15B F16A F16B F19B F29A F38 F380 F60C F61C F62C F63C F64C F65C F7036FA02 FA2A FA4H FBI FBM FBP FC FCB FCC FCU FD200 FD400 FD600 FD800 FDM FE FE2475FEE FEH FF FG Page 381-383 381-383 381-383 381-383 381-383 381-383 381-383 381-383 381-383 * * 411 * * 225 191-192 * * * * * * * * * * * * * * * * * * 402 * * * * * * * * * * * 66 66 * * * * * 344 340-344 340-343, 346 340-343, 346 * 191-192, 194 * 191-192, 194 * 226 226 Catalog Number Page FH2 * FHL * FHN * FL* FL11H_ 88 FL11K__ 88 FL11N * FL11T__ 88 FL12K__ 88 FL1A5 * FL3H * FL3K__ 88 FL3T__ 88 FLB * FLD * FLF * FLM * FLN * FLS * FM 191-192, 194 FM01A * FM08A * FM09A * FM09B * FMM 191-192, 194 FMX * FNA 51 FNJ * FNM 49 FNQ 49 FNQ-R 18 FNW * FP-_ 414 FR-1000 * FRN-R 35 FRN-R-__ID 35 FRS-R 36 FRS-R-__ID 36 FSD * FT-_ 414 FTI * FTM * FWA 98-101, 197-198 FWC 205-206 FWH 104-105, 201-204 FWJ 111-112, 213-214 FWK 211-212 FWL 215 FWP 207-210 FWS 215 FWX 102-103, 199-200 G30060 274 GBA 51 GBB 63 GBB-V 63 GBC * GDA 59 GDA-V 59 GDB 59 GDB-V 59 GDC 60 GDC-V 60 GF 226 GFA * Catalog Number GG GH GKB GKJ GLD GLH GLN GLP GLQ GLR GLX GMA GMA-V GMC GMC-V GMD GMD-V GMF GMQ GMTGMT-A GMW GOB GRF GSK-260 H07C H25_ H60_ HAC-R HAS-R HBC HBH-I HBH-M HBM HBO HBPHBSHBV-I HBV-M HBW-I HBW-M HCHC1 HC2 HC3 HC7 HC8 HCM HEB HEC HEF HEG HEH HEJ HET HEX HEY HFA HFB HGA HGB HGC HHB HHC Page 226 226 * * 51 * * 235 53 54 * 61 61 61 61 61 61 54 53 399 399 * * 54 410 224 260-262 263-265 * * * 66 66 * * * * 66 66 66 66 * * * * * * * 279-280 279 * 279 279 279 279 279 279 278 277 * * * 277 56 Catalog Number HHD HHF HHG HHI HHJ HHL HHM HHT HHX HIF HJL HJM HKA HKL HKP HKQ HKR HKT HKU HKX HLA HLD HLQ HLR HLS HLT HME HMF HMG HMH HMI HMJ HMK HMR HN-1 HN-3 HN-5 HOB HOF HPC-D HPD HPF HPG HPL HPM HPS HPS2 HRE HRF HRG HRH HRI HRJ HRK HSK HTBHTC-10M HTC-140M HTC-15M HTC-200M HTC-210M HTC-30M HTC-35M HTC-40M Page 56 56 56 278 278 56 56 278 56 * 285 * * 285 282 * 285 285 285 285 * 285 53 54 399 399 278 278 278 278 278 278 * * * * * * * 287 286 286 286 * 287 286 287 278 278 278 278 278 278 277 * 283-284 * 67 67 67 67 * 281 281 Catalog Number HTC-45M HTC-50M HTC-55M HTC-60M HTC-65M HTC-70M HVA HVB HVJ HVL HVR HVT HVU HVW HVX HWA IXL70F J-_ _ J101/J J201/J J301/J J60__ J70032 J70100 JA600 JB1 JB3 JCA JCDJCEJCGJCHJCIJCKJCK-AJCK-BJCLJCL-AJCL-BJCM JCN JCP JCQJCR-A JCR-BJCTJCUJCWJCXJCYJCZJDN JDZJF1 JJNJJSJKS JN JP600 JPA-3 JSK-36 JT JTN JU Page 65 65 281 65 65 281 87 87 87 87 87 87 87 87 87 * * 415 * * * 266-267 216 216 268 * * * 78 * 80, 82 80-81 78 80-81 80-81 80-81 80-81 80, 82 80, 82 * * * 78 80, 82 80, 82 78 74-75 78 74 74 74-75 * 74-75 * 38 39 24 * 268 * 410 255-256 255-256 * * Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Call 636-527-3877. 438 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 438 Index Catalog Number Index Catalog Number 258 224 * * 106 * * * * * * 52 107 * * * * * * 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 * * * 46 46 46 46 46 46 * * * * * * * Catalog Number KGS-A KGT KGX KGY KIG KJA KJB KLC KLM KLP KLU KMH-C KOS15 KPF KQO KQT KQV KQW-M KRP-C__SP KRP-CL KS-19392-L36 KT3KT4KTE KTJ KTK KTK-R KTN-R KTN-S KTQ KTS-R KTS-S KTU KU KUH KURL KUSC KUX KUXRL KUXSC KWN-R KWS-R L09C L14C LA LA8D324 LAA LAC LAG LAN LAR LCT LCU LD1 LD2 LEF LET LKB LKC LKN LKS LMMT LMT LP-CC Page * * * * 46 * * * 47 * 28 * * 46 46 46 46 * 26-27 27 * 310 310 * * 47 19 32 * 50 * * 28 321 321 321 321 321 321 321 * 33 224 224 * * * * * * * 188-189 * * * * 188-189 * * * * 188, 190 188, 190 17 Catalog Number LPF1LPJ__SP LPJ__SPI LPN-RK__SP LPN-RK__SPI LPRK-28 LPS-RK__SP LPS-RK__SPI LPT LS1D3 M09C M14C MAI MAS MAXMAX-__ID MBMBO MC_ _ _ MCRW MDA MDA-V MDF MDL MDL-V MDM MDQ MDQ-V MDX MFN MIC MIJ MIN MIS MKA MKB MKG MMB MMT MPR MS100 MSK-45 MSL MSW710 MT MT12 MTC6 MTH MTMU MV055MV155N512-BK NBB NBC NBE NC3ND-1260 NDN111NDN1A-WH NDN1-WH NDN3NDN63NDNA100 NDNA200 Page 291 23 23 29-31 29-31 411 29-31 29-31 * * 224 224 195 * 55 55 42 * 195 * 64 64 * 64 64 * 64 64 * * 51 * 51 52 * * * * 191-193 * * 410 * * 191-193 * * * * 73 73 306 * * * 307 * 305 305 305 304 304 305 305 Catalog Number NDNAS NDND1 NDNF1-WH NDNFD1-WH NDNLFD1-WH NDNV4NFA NFT2NFT3NFTA _NHG _ _ _ B NI NITD NNB NNB-R NNC NO.1 NO.100 NO.140 NO.15 NO.2 NO.201 NO.204 NO.205 NO.213 NO.213-R NO.216 NO.216-R NO.220 NO.226 NO.226-R NO.242-R NO.2621 NO.2621-R NO.263 NO.263-R NO.2641 NO.2641-R NO.2642 NO.2661-R NO.2662-R NO.2664-R NO.270 NO.2880 NO.36 NO.4 NO.5 NO.6 NO.616 NO.616-R NO.626 NO.626-R NO.642-R NO.663 NO.663-R NO.7 NO.8 NON NOS NPL NRA NSD NSE3-WH NSS3- Page 305 * 291 291 291 304 * 306 306 305 228-231 235 225 415 415 415 413 * 412 * 413 * * * 415 415 415 415 412 415 415 415 415 415 415 415 415 415 415 415 415 415 412 * 411 413 413 413 415 415 415 415 415 415 415 413 413 25 25 * 305 225 307 307 Catalog Number Page NTN-R415 NTQ23-WH 311 NTS-R415 NUE * NXA * NXC * __NZ01 227 __NZ02 227 OEFMA 86 OEGMA 86 OHFMA 86 OHGMA 86 OIA * OJ * OLGMA 86 OPM-1038 250-251 OPMNGSA 252-253 OPMNGSAAUX 252-253 OPM-NG-SC3 252-253 OPM-NG-SM3 252-253 OSD 225 OSP * P41 P09C 224 P11C 224 PCB * PCC * PCD * PCF * PCG * PCH * PCI* PCT 399 PDB___ 296 PDBFS___ 295 PF1 274 PF1291 PLK3-WH 310 PLU11-WH 309 PLU111-WH 309 PLU1-WH 309 PLU3309 PMP 240-241 PON 219 PS 240-241 PS1RPLSW * PSU11-WH 309 PSU111-WH 309 PSU1-WH 309 PV48 PVS-R 37 QC202/J * QC203/J * Quik-Spec AC Safety Switches Switches 245-246 Quik-Spec Coordination Panelboards 238-239 Quik-Spec DC Safety Switches 242 Quik-Spec Solar Combiner Boxes 243-244 R11C 224 R25_ 260-262 R60_ 263-265 * Not listed in this catalog. Call Cooper Bussmann Customer Satisfaction for more information. Call 636-527-3877. 439 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 439 Services & Application Guide JV-L K07C KAA KAB KAC KAD KAF KAJ KAL KAW KAX KAZ KBC KBD KBJ KBO KBR KBT KBY KCA KCB KCC KCD KCE KCF KCH KCJ KCM KCM-B KCR KCS KCV KCY KCZ KDA KDB KDC KDD KDE KDF KDH KDJ KDM KDP KDR KDT KDU KDY KEF KEM KER KEW KEX KFH-A KFM KFT KFZ KGC KGJ KGJ-A KGJ-E KGL KGO-E KGS Page Index Catalog Number Index Catalog Number REG REN RES RFI RFL RK1SK-39 RK5SK-39 RLA RLC RYA RYC SS3Holder S500 S500-V S501 S501-V S504 S505 S505-V S506 S506-V S-8001 S-8002 S-8101 S-8102 S-8201 S-8202 S-8203 S-8301 SASAMISB SC SCV15 SCV20 SCY SDA SDLSJ SDMSJ SDQ SDQSJ SEW-5B SF25H SFB1030 SFC-FUSE-CAB SFC-SHELF SFD27 SFE SFLSJ SFMSJ SFQSJ SFR SFR1 SKA SKLSJ SLSM363 SNF-7K SNF-7M SNL-7K SOA72 SOU SOW 440 Page Catalog Number * * * * * 410 410 * * * * 41 * 59 59 59 59 * 59 59 60 60 288 288 288 288 288 288 288 288 42 259 186 22 * * 276 * * * * * * * * 414 414 * * * * * * * 276 * 40 * * * * 305 276 276 SOX SOY SPJ SPP SRA-R SRD SRT-A SRU SRU-BC SRW SRX SRY SSD SSN SSU SSW SSX SSY STD STI STM STY SYC SZQ TT1320-2R T30__ T60__ TB100TB200TB200HBTB300TB345TB400TC TCF TCF__RN TCFH__N TCP TDC TDC10 TDC11 TDC180 TDC600 TDLEJ TDLSJ TDMEJ TDP TDQSJ TFC TFF TFL TFLSJ TFMEJ TFQSJ TGC TGH THL THLEJ THMEJ TIQ TJD TKLEJ TKMEJ Page 276 276 * * * * * 276 * 276 276 276 225 276 276 276 276 276 225 * * 276 * * 41 * 269-270 271-272 312-313 314-315 314-315 316-317 316-317 320 41 20-21 20-21 20-21 * * * * * * 84 84 84 * 84 * * * 84 84 84 * * * 84 84 * * 84 84 Catalog Number TLTP158HC TP15900 TP15900-4 TP15914 TPA TPA-B TPB TPC TPCDS TPH TPHCSTPJ TPLTPM TPMDS TPN TPS TPSFHTPW TPWDS TRF TSTVS TVSSTXLEJ TXMEJ TXQEJ UHA UHC UHJ UHS UHT UHW ULR VFNHA VKNHA WWDFHO WDLSJ WDOH6 WDOSJ WER WFFHO WFLSJ WFMSJ WFNHO WFOH6 WFOSJ WGA WHA WHN WIE WJON6 WKB WKFHO WKH WKJ WKK WKL WKLSJ WKMSJ WKNHO WKS Page 40 393 * 391 390 391 391 * 388 388 * 395 * 396 389 389 397 392 414 * * * 322-324 406 407 84 84 84 * * * * * * * 83 83 40 83 83-84 83 84 400 83 83 83 83 83 84 * * * * 83 * 83 * * * * 84 83-84 83 * Catalog Number WKU WKV WLF WMB WMM WMQ WPQ WQL WQN WQP WSE WSH WSL WSM WSP WSQ WST WSU WTJ WTK WTT WTZ WUC WUD WUE WUG WUH WUI WUQ WUR WUU WUV WUW WUY WVA WVQ WVR WWD WWE WWF WWG WWI WWK WWL WWU WWV WWX WYG WYM WZC WZJ WZK WZL WZX XL25X XL50F XL70F Page * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa Catalog Number Page Sales & Support Sales Support & Manufacturing Facilities North America - World Headquarters Asian Headquarters Cooper Bussmann 114 Old State Road Ellisville, Missouri 63021 Telephone: 636-527-3877 Fax: 800-544-2570 Email: fusebox@cooperindustries.com Cooper Electric (Shanghai) Co. Ltd. 955 Shengli Road Heqing Pudong, Shanghai 201201 China Telephone: 8621-2899-3888 Fax: 8621-2899-3997 Cooper Bussmann Mexico Poniente 148 No.933 Col. Industrial Vallejo Azcapotzalco C.P. 02300, Mexico D.F. Telephone: +52-55-5587-0211 Ext.720 Fax: +52-55-5567-1131 E-mail: ventasbussmannmexico@cooperindustries.com Cooper Bussmann Transportation 10955 SW Avery St. Tualatin, OR 97062 Telephone: 503-692-5360 Fax: 503-692-9091 E-mail: SurePower.Sales@cooperindustries.com Cooper Bussmann Electronics 1225 F Broken Sound Parkway NW Boca Raton, FL 33487 Telephone: 561-988-4100 Fax: 561-241-6640 E-mail: customerservice@cooperindustries.com Bussmann India Cooper Bussmann, India, Pvt. Ltd. 2, EVR Street, Sedarpet Indl. Estate, Pondicherry - 605 111 India Telephone: 91-413-267-2005 Fax: 91-413-267-8182 E-mail: sales.india@cooperindustries.com European Headquarters Cooper (UK) Ltd. Melton Road Burton-on-the-Wolds Leicestershire LE12 5TH England Telephone: 44-1509-882737 Fax: 44-1509-882786 E-mail: bule.sales@cooperindustries.com South American Headquarters Cooper Bussmann Brazil Bussmann do Brasil Ltda. Rodovia Santos Dumont, km 23 13.300-000, Caixa Postal 095 Itu Sao Paulo Brazil Telephone: 55-11-4024-8400 Fax: 55-11-40-24-8424 Services & Application Guide For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 441 Circuit Protection Products for the Electrical Industry Cooper Bussmann(R) Fuse Cross Reference & Low-Peak(R) Upgrade The left column represents Cooper Bussmann and competitors' part numbers. The right column represents the Cooper Bussmann upgrades. The Cooper Bussmann(R) fuse upgrade offers superior performance while reducing the number of SKUs that need to be in stock. Low-Peak(R) fuses feature a high degree of current limitation, which will provide the best component protection and may reduce the arc-flash hazard. Listings are alphanumerical by fuse class and fuse catalog symbol. This list is only a consolidated cross reference to some of our most common products. For a much more extensive database please consult the Product Profiler competitor cross-reference. Just visit www.cooperbussmann.com and click on the magnifying glass icon in the upper right corner. Class CC and Midget Existing Fuse A6Y (type 2B) ABU AGU ATDR ATM ATMR ATQ BAF BAN BLF BLN CCMR CM CMF CNM CNQ CTK CTK-R FLM FLQ FNM FNQ GGU HCLR KLK KLK-R KTK KTK-R MCL MEN MEQ MOF MOL OTM TRM 6JX Low-Peak(R) Upgrade LP-CC Class L Class J Existing Fuse A4J AJT CJ CJS GF8B HRCXXJ J JA JCL JDL JFL JHC JKS JLS JTD Low-Peak(R) Upgrade LPJ_SP LPJ_SP 250 Volt Class R Existing Fuse A2D A2D-R A2K A2K-R A2Y (type 1) AT-DE CHG CRN-R (type 3) CTN-R DEN DLN DLN-R ECN ECN-R ERN FLN FLN-R FRN FRN-R FTN-R GDN HAC-R HB KLN-R KON KTN-R LENRK LKN LLN-RK LON-RK NCLR NLN NON NRN OTN REN RFN RHN RLN TR 655 660 10KOTN 50KOTN Existing Fuse A4BQ A4BT A4BY A4BY (type 55) CLASS L CLF CLL CLU HRC-L KLLU KLPC KLU KTU L LCL LCU Low-Peak(R) Upgrade KRP-C_SP KRP-C_SP 600 Volt Class R (R) Low-Peak Upgrade LPN-RK_SP Existing Fuse A6D A6K-R A6X (type 1) ATS-DE CHR CTS-R DES DES-R DLS DLS-R ECS-R ERS FLS FLS-R FRS FRS-R FTS-R GDS HA KLS-R KOS KTS-R LES LES-R LES-RK LKS LLS-RK LOS-RK NLS NOS NRS OTS RES RFS RHS RLS SCLR TRS TRS-R 656 10KOTS 50KOTS Low-Peak(R) Upgrade LPS-RK_SP LPS-RK_SP LPN-RK_SP LP-CC *FNQ-R suggested on primary of control transformers. ATQR FNQ-R FNQ-R KLDR The comparative catalog numbers shown were derived from the latest available published information from various manufacturers. Because competitors' products may differ from Cooper Bussmann products, it is recommended that each application be checked for required electrical and mechanical characteristics before substitutions are made. Cooper Bussmann is not responsible for misapplications of our products. Overcurrent protection is application dependent. Consult the latest catalogs and application literature, or contact our Application Engineering Department at (636) 527-1270. Customer Assistance Application Engineering Technical assistance is available to all customers. Staffed by degreed electrical engineers, this application support is available Monday-Friday, 8:00 a.m. - 5:00 p.m. Central Time. Contact: Customer Satisfaction Team Available to answer questions regarding Cooper Bussmann products & services Monday-Friday, 8:00 a.m. - 6:00 p.m. Central Time. Contact: * Phone: 636-527-3877 * Toll-free fax: 800-544-2570 * E-mail: busscustsat@cooperindustries.com * * * * Emergency and After-Hours Orders Next flight out or will call shipment for time-critical needs. Customers pay only standard product price, rush freight charges, & modest emergency service fee. Place these orders through the Customer Satisfaction Team during regular business hours. For after-hours, contact: Phone: 636-527-1270 Fax: 636-527-1607 E-mail: fusetech@cooperindustries.com Live Chat: www.cooperbussmann.com Online Resources Visit www.cooperbussmann.com for the following resources: * Product search & cross-reference * Product & technical materials * Solutions centers for information on topical issues including arc-flash, selective coordination & short-circuit current rating * Technical tools, like our arc-flash calculator * Where to purchase Cooper Bussmann product * After hours 314-995-1342 C3 - the Enhanced, Online Cooper Customer Center Provides real time product availability, net pricing, order status & shipment tracking across six Cooper divisions: B-Line, Bussmann, Crouse-Hinds, Lighting, Power Systems & Wiring Devices. Call 877-995-5955 for log-in assistance. Available at: Services Cooper Bussmann Services team provides engineering expertise in electrical system reviews, electrical safety training & component testing for Agency compliance. Contact: * www.cooperc3.com * Phone: 636-207-3294 * E-mail: services@cooperindustries.com Cooper Bussmann(R) St. Louis, MO 63178 636-394-2877 w w w. c o o p e r b u s s m a n n . c o m Your Authorized Cooper Bussmann Distributor is: Cooper Industries plc 600 Tra vis, Ste. 5600 Houston, TX 77002-1001 P: 713-209-8400 www.cooperindustries.com Reorder # 1007 0210-55M Printed in USA