EcoCableTM and EcoFlexTM Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoCable and EcoFlex cable are Alpha Wire's newest innovations in control cabling. A true engineering breakthrough, EcoCable and EcoFlex cable combine better performance with a minimum environmental impact. Each derives its advantages from modified polyphenylene ether (mPPE) jacketing and insulation. EcoCable is: * 100% Recyclable * Up to 47% smaller * Up to 65% lighter * Capable of handling temperatures extremes to -50C * Up to 87% lower outgassing mPPE Insulation: All the Advantages in Smaller, Lighter Control Cable Environmentally Friendly Better Dielectric Strength Superior Availability EcoCable and EcoFlex cables contain no halogens, phthalates, or heavy metals. The mPPE thermoplastic insulation and jacketing can be easily recycled. They meet RoHS and WEEE requirements for the elimination of hazardous substances and recyclability. The superior dielectric properties of mPPE make a reduced wall thickness possible, while maintaining the same electrical properties as a thicker PVC control cable. EcoCable and EcoFlex cable are available from stock in most sizes and constructions, with put-ups as small as 100 feet. Alpha Wire provides same-day shipment and next-day delivery to practically anywhere in the world. Low Specific Gravity The 1.03 specific gravity of mPPE is 25% to 40% lower than other insulation materials, such as PVC, polyethylene, and cross-linked polyethylene. Along with the reduced wall thickness, the low specific gravity yields significant weight savings of up to 65% with EcoCable. More Choice in EMI Protection Alpha Wire offers EcoCable and EcoFlex cable in three shielding options to handle any electrical environment. Visit www.alphawire.com/ EcoGen to request free samples * Unshielded * Foil Shielded * S upraShield(R) Foil + Braid Shield Alpha Wire's next generation of eco-friendly, high-performance wire and cable, designed to provide better performance in a smaller package. * EcoCableTM * EcoFlexTM Cable Properties Diameter Weight Temperature Range Outgassing Recyclability Availability EcoCable Up to 47% smaller 65% lighter -50C to 105C 87% lower 100% 100', 1000' EcoFlex Cable Up to 32% smaller 55% lighter -40C to 105C static, -5C to 105C Flexing 91% lower 100% 100', 1000' * EcoWireTM * EcoWireTM Plus Learn more about the new EcoGen family of products at www.alphawire.com/EcoGen EcoCable Specifications Request free samples at www.alphawire.com/ EcoCable Materials Approvals Conductor No Conductors: Stranded tin-plated copper Insulation: mPPE Jacket: mPPE, slate * U L AWM 21270 (600 V, 105C) No. Base Color * UL VW-1 1 Black 2 Brown Electrical * RoHS Compliant 3 Red 4 Orange * CE * CSA AWM I/II A/B 1st Stripe 2nd Stripe Voltage: 600 V * REACH Compliant * WEEE 5 Yellow Bend Radius * S uitable for use in NFPA 79 applications 6 Green 7 Blue 8 Violet 9 Slate Temperature Range: -50C to 105C 10 White 11 White Black Availability 12 White Brown 100 ft (30.5 m) and 1000 ft (305 m) lengths 13 White Red 14 White Orange 15 White Yellow 16 White Green 17 White Blue 18 White Violet 19 White Slate 20 White Black Brown 21 White Black Red 22 White Black Orange 23 White Black Yellow 24 White Black Green 25 White Black Blue 6x * IEC 60332-2 Flame Behavior Physical and Mechanical 22 AWG (0.35 mm2) Cable EcoCable Unshielded 24 AWG (0.28 mm2) 18 AWG (0.81 mm2) Stranding: 7/32 (0.20 mm ) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 16/30 (0.25 mm2) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) 2 Part Number Conductors 77001 2 77002 77003 Nominal Diameter Part Number Conductors 77020 2 Nominal Diameter Inch mm Inch mm 0.156 3.96 0.202 5.13 4 0.175 4.44 77021 3 0.213 5.41 5 0.188 4.78 77022 4 0.230 5.84 77004 7 0.201 5.11 77023 5 0.250 6.35 77005 9 0.229 5.82 77024 7 0.271 6.88 77006 19 0.288 7.32 77025 9 0.313 7.95 77026 12 0.346 8.79 77027 15 0.377 9.58 77028 19 0.404 10.26 77029 25 0.470 11.94 22 AWG (0.35 mm2) 16 AWG (1.32 mm2) Stranding: 7/30 (0.25 mm2) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 19/0.0117 (0.297 mm2) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Nominal Diameter Nominal Diameter Part Number Conductors Inch mm 4.27 77030 4 0.259 6.58 4.80 77031 5 0.283 7.19 0.204 5.18 77032 7 0.307 7.80 0.219 5.56 77033 9 0.357 9.07 Part Number Conductors Inch mm 77007 2 0.168 77008 4 0.189 77009 5 77010 7 77011 9 0.251 6.38 77034 12 0.396 10.06 77012 19 0.318 8.08 77035 15 0.433 11.00 77036 19 0.464 11.79 77037 25 0.542 13.77 Part Number 20 AWG (0.56 mm2) 14 AWG (2.08 mm2) Stranding: 7/28 (0.32 mm2) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 41/30 (0.25 mm2) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.032 (0.81 mm) Conductors Nominal Diameter Inch mm Part Number Conductors Nominal Diameter Inch mm 77013 3 0.193 4.90 77038 2 0.260 6.60 77014 4 0.209 5.31 77039 3 0.275 6.98 77015 9 0.280 7.11 77040 4 0.301 7.65 77016 12 0.309 7.85 77041 5 0.329 8.36 77017 15 0.336 8.53 77042 7 0.358 9.09 77018 19 0.358 9.09 77043 9 0.419 10.64 77019 25 0.416 10.57 77044 12 0.467 11.86 77045 15 0.511 12.98 77046 25 0.644 16.36 EcoCable Foil Shield 24 AWG (0.28 mm2) 18 AWG (0.81 mm2) Stranding: 7/32 (0.20 mm ) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 16/30 (0.25 mm2) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) 2 Part Number Conductors 77102 2 Nominal Diameter Part Number Conductors 6.48 77124 2 Inch mm 0.255 Nominal Diameter Inch mm 0.206 5.23 77103 3 0.16 4.06 77126 3 0.217 5.51 77104 4 0.167 4.24 77127 4 0.234 5.94 77105 5 0.179 4.55 77128 5 0.254 6.45 77106 7 0.192 4.88 77129 7 0.275 6.98 77107 9 0.205 5.21 77130 9 0.317 8.05 77101 12 0.233 5.92 77121 12 0.350 8.89 77122 15 0.381 9.68 77123 19 0.408 10.36 77125 25 0.474 12.04 22 AWG (0.35 mm2) 16 AWG (1.32 mm2) Stranding: 7/30 (0.25 mm2) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 19/0.0117 (0.297 mm2) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Nominal Diameter Nominal Diameter Part Number Conductors 4.37 77133 2 4.57 77134 3 0.242 6.15 4 0.263 6.68 5 0.287 7.29 Part Number Conductors Inch mm 77109 2 0.172 77110 3 0.180 77111 4 0.193 4.90 77135 77112 5 0.208 5.28 77136 Inch mm 0.230 5.84 77113 7 0.223 5.66 77137 7 0.311 7.90 77114 9 0.255 6.48 77138 9 0.361 9.17 77108 12 0.280 7.11 77131 12 0.400 10.16 77132 15 0.437 11.10 14 AWG (2.08 mm2) 20 AWG (0.56 mm2) Stranding: 41/30 (0.25 mm2) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 7/28 (0.32 mm ) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) 2 Part Number Conductors 77116 3 77117 4 77118 5 Nominal Diameter Part Number Conductors 5.00 77141 2 0.213 5.41 77142 0.230 5.84 77143 Inch mm 0.197 Nominal Diameter Inch mm 0.264 6.71 3 0.279 7.09 4 0.305 7.75 77119 7 0.247 6.27 77144 5 0.333 8.46 77120 9 0.284 7.21 77145 7 0.362 9.19 77115 12 0.313 7.95 77146 9 0.423 10.74 77139 12 0.471 11.96 77140 15 0.515 13.08 EcoCable Supra-Shield(R) Foil + Braid 24 AWG (0.28 mm2) 18 AWG (0.81 mm2) Stranding: 7/32 (0.20 mm ) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 16/30 (0.25 mm2) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) 2 Part Number Conductors 77201 Nominal Diameter Nominal Diameter Part Number Conductors 5.16 77213 2 0.229 5.82 77214 3 0.241 6.12 0.279 7.09 77215 4 0.258 6.55 77216 5 0.278 7.06 77217 7 0.299 7.59 77218 9 0.341 8.66 Inch mm 4 0.203 77202 7 77203 12 Inch mm 0.230 5.84 77219 12 0.374 9.50 77220 15 0.405 10.29 77221 19 0.432 10.97 22 AWG (0.35 mm2) 16 AWG (1.32 mm2) Stranding: 7/30 (0.25 mm2) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 19/0.0117 (0.297 mm2) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Nominal Diameter Conductors Inch mm 5.51 77222 2 0.254 6.45 0.247 6.27 77223 3 0.266 6.76 0.304 7.72 77224 4 0.287 7.29 77225 5 0.311 7.90 Conductors Inch mm 77204 4 0.217 77205 7 77206 12 77226 7 0.335 8.51 77227 9 0.385 9.78 77228 12 0.424 10.77 77229 15 0.461 11.71 77230 19 0.492 12.50 20 AWG (0.56 mm2) 14 AWG (2.08 mm2) Stranding: 7/28 (0.32 mm ) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 41/30 (0.25 mm2) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.032 (0.81 mm) 2 Part Number Conductors 77207 Nominal Diameter Part Number Part Number Nominal Diameter Part Number Conductors 6.02 77231 0.254 6.45 0.271 6.88 0.308 7.82 77234 0.337 8.56 77235 0.386 9.80 77236 Inch mm 4 0.237 77208 5 77209 7 77210 9 77211 12 77212 19 Nominal Diameter Inch mm 2 0.288 7.32 77232 3 0.303 7.70 77233 4 0.329 8.36 7 0.386 9.80 9 0.447 11.35 12 0.495 12.57 77237 15 0.539 13.69 77238 25 0.678 17.22 EcoFlex Cable Specifications Request free samples at www.alphawire.com/ EcoFlex Materials Key Features Conductor No Conductors: Stranded tin-plated copper Insulation: mPPE Jacket: mPPE, slate * C ompact cable for moderate flex applications No. Base Color * R ated for more than 1 million flex cycles 1 Black 2 Red 3 White Approvals 4 Green * U L AWM 21819 (600 V, 105C) 5 Orange * UL AWM 21492 (300 V, 80C) 6 Blue * CE 7 Brown 8 Yellow 9 Violet * REACH Compliant 10 Slate * WEEE * Suitable for use in NFPA79 Applications 11 Pink 12 Tan 13 Red Green 14 Red Yellow 15 Red Black 16 White Black 17 White Red 18 White Green 19 White Yellow 20 White Blue 21 White Brown 22 White Orange 23 White Slate 24 White Violet 25 White Black Electrical Voltage: 600 V Bend Radius Unshielded: 5x Static, 5x Flexing Shielded: 6x Static, 8x Flexing Physical and Mechanical Temperature Range: -40C to 105C Availability 100 ft (30.5 m) and 1000 ft (305 m) lengths * Easier routing and handling * UL VW-1 * RoHS Compliant * CSA AWM I/II A/B FT1 * IEC 60332-2 Flame Behavior 20 AWG (0.51 mm2) Cable 1st Stripe 2nd Stripe Red EcoFlex Cable Unshielded 20 AWG (0.51 mm2) 14 AWG (2.08 mm2) Stranding: 10/30 (0.25 mm ) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 41/30 (0.25 mm2) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.81 mm) 2 Part Number Conductors 79001 2 Nominal Diameter Inch mm 0.184 4.67 Part Number Conductors 79028 2 Nominal Diameter Inch mm 0.266 6.76 79002 3 0.193 4.90 79029 3 0.281 7.14 79003 4 0.207 5.26 79030 4 0.307 7.80 79004 5 0.224 5.69 79031 5 0.335 8.51 79005 7 0.240 6.10 79032 7 0.364 9.25 79006 9 0.296 7.52 79033 9 0.459 11.66 79007 12 0.303 7.70 79034 12 0.473 12.01 79008 18 0.349 8.86 79035 18 0.556 14.12 18 AWG (0.81 mm2) 12 AWG (3.29 mm2) Stranding: 16/30 (0.25 mm2) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 65/30 (0.25 mm2) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Nominal Diameter Conductors Inch mm 5.28 79037 3 0.326 8.28 5.56 79038 4 0.358 9.09 5.99 79039 5 0.392 9.96 6.50 79040 7 0.428 10.87 Conductors Inch mm 79010 2 0.208 79011 3 0.219 79012 4 0.236 79013 5 0.256 79014 7 0.277 7.04 79015 9 0.344 8.74 79016 12 0.353 8.97 79017 18 0.411 10.44 Part Number Nominal Diameter Part Number Part Number 16 AWG (1.32 mm2) 10 AWG (5.32 mm2) Stranding: 26/30 (0.25 mm2) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 105/30 (0.25 mm2) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Conductors Nominal Diameter Inch mm Part Number Conductors Nominal Diameter Inch mm 79019 2 0.236 5.99 79041 3 0.38 9.65 79020 3 0.249 6.32 79042 4 0.423 10.74 79043 5 0.465 11.81 79021 4 0.270 6.86 79022 5 0.294 7.47 79023 7 0.319 8.10 79024 9 0.400 10.16 79025 12 0.411 10.44 79026 18 0.481 12.22 EcoFlex Cable Braid Shield 20 AWG (0.51 mm2) 14 AWG (2.08 mm2) Stranding: 10/30 (0.25 mm ) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 41/30 (0.25 mm2) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.81 mm) 2 Part Number Conductors 79101 2 Nominal Diameter Part Number Conductors 5.33 79121 Inch mm 0.210 Nominal Diameter Inch mm 2 0.294 7.47 79102 3 0.219 5.56 79122 3 0.309 7.85 79103 4 0.233 5.92 79123 4 0.335 8.51 79104 5 0.250 6.35 79124 5 0.363 9.22 79105 7 0.266 6.76 79125 7 0.392 9.96 79106 9 0.321 8.15 79107 12 0.329 8.36 79108 18 0.376 9.55 18 AWG (0.81 mm2) 12 AWG (3.29 mm2) Stranding: 16/30 (0.25 mm2) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 65/30 (0.25 mm2) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Nominal Diameter Conductors Inch mm 5.99 79126 3 0.354 8.99 0.247 6.27 79127 4 0.386 9.80 4 0.264 6.71 5 0.284 7.21 Conductors Inch mm 79109 2 0.236 79110 3 79111 79112 79113 7 0.305 7.75 79114 9 0.372 9.45 79115 12 0.381 9.68 16 AWG (1.32 mm2) Stranding: 26/30 (0.25 mm2) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.89 mm) Part Number Nominal Diameter Part Number Part Number Conductors Nominal Diameter Inch mm 79116 2 0.262 6.65 79117 3 0.275 6.98 79118 4 0.396 10.06 79119 5 0.320 8.13 79120 7 0.345 8.76 EcoFlex Cable Supra-Shield(R) Foil + Braid 20 AWG (0.51 mm2) 14 AWG (2.08 mm2) Stranding: 10/30 (0.25 mm ) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 41/30 (0.25 mm2) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.81 mm) 2 Part Number Conductors 79201 2 Nominal Diameter Part Number Conductors 5.49 79225 2 Inch mm 0.216 Nominal Diameter Inch mm 0.300 7.62 79202 3 0.225 5.72 79226 3 0.315 8.00 79203 4 0.239 6.07 79227 4 0.341 8.66 79204 5 0.256 6.50 79228 5 0.369 9.37 79205 7 0.272 6.91 79229 7 0.398 10.11 79206 9 0.328 8.33 79230 9 0.493 12.52 79231 12 0.507 12.88 79207 12 0.335 8.51 79208 18 0.382 9.70 18 AWG (0.81 mm2) 12 AWG (3.29 mm2) Stranding: 16/30 (0.25 mm2) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 65/30 (0.25 mm2) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Nominal Diameter Conductors Inch mm 6.15 79232 3 0.360 9.14 0.253 6.43 79233 4 0.391 9.93 4 0.270 6.86 79234 5 0.426 10.82 5 0.290 7.37 79235 7 0.462 11.73 Conductors Inch mm 79210 2 0.242 79211 3 79212 79213 79214 7 0.311 7.90 79215 9 0.378 9.60 79216 12 0.387 9.83 79217 18 0.445 11.30 Part Number Nominal Diameter Part Number Part Number 16 AWG (1.32 mm2) 10 AWG (5.32 mm2) Stranding: 26/30 (0.25 mm2) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 105/30 (0.25 mm2) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Conductors Nominal Diameter Inch mm Part Number Conductors Nominal Diameter Inch mm 79218 2 0.268 6.81 79236 3 0.419 10.64 79219 3 0.281 7.14 79237 4 0.457 11.61 79220 4 0.302 7.67 79221 5 0.326 8.28 79222 7 0.351 8.92 79223 9 0.432 10.97 79224 12 0.443 11.25 Cables you trust. Service you deserve. Superior availability Every application is critical and cable failure is not an option when the safety of your equipment and personnel is paramount. Specify Alpha products since the integrity of your system is only as robust as the products you use. Alpha offers wire and cable from stock in most sizes and constructions, in both small and large put-ups, so you can order it when you need it. Our products are available for same-day shipment, eliminating long lead times. GLOBAL HEADQUARTERS 711 Lidgerwood Avenue Elizabeth, NJ 07207-0711 USA Toll Free: 1-800-52 ALPHA Tel: 1-908-925-8000 Fax: 1-908-925-5411 E-mail: info@alphawire.com EUROPE Alpha Wire International Saxon House 1 Downside | Sunbury-on-Thames Middlesex | United Kingdom TW16 6RT Tel: +44-(0)-800-288-8809 Fax: +44-(0)-800-288-8810 E-mail: europe@alphawire.com Service and support, second-to-none Selecting the correct cable for your critical application is essential to overall system reliability, performance, and safety. So we make it easy for you select the right Alpha product for your specific application. Our online resources include a wire and cable selection guide, technical information, full product catalog, and a distributor locator to make it easy to select and get the wire or cable you need. Can't find what you're looking for? Design the cable to your specification. It's easy, just visit www.alphawire.com! ASIA PACIFIC Alpha Wire Silver Center | Room 1708 North Shanxi Road 1388 Shanghai | China | 200060 Tel: +86-21-61498201/61498205 Fax: +86-21-61498001 E-mail: apac@alphawire.com Alpha Wire's next generation of eco-friendly, high-performance wire and cable, designed to provide better performance in a smaller package. (c)2012 Alpha Wire. All rights reserved. Specifications subject to change. Consult Alpha Wire for latest specifications. EcoCable, EcoFlex, EcoGen, EcoWire, and EcoWire Plus are trademarks of Alpha Wire. Lit. No. EcoC-Bro-1209 Supersedes: New