15 Watts
•Low Cost
•Output Voltages from 5 to 24 V
•PCB Mounting
•Open Frame & Encapsulated Versions
•IT & Medical Approvals
•Class II Construction
•No Load Input Power <0.3 W
VCP Series
Input
Input Voltage • 90-264 VAC
Input Frequency • 47-63 Hz
Input Current • 0.5 A max at 90 VAC
Inrush Current • 40 A max at 240 VAC, cold start at 25 °C
Power Factor • EN61000-3-2, class A
No Load Input Power • <0.3 W
Input Protection • Internal T2.0A/250 V fuse in line
Output
Output Voltage • See table
Initial Set Accuracy • ±2% at 50% load
Minimum Load • No minimum load required
Start Up Delay • 2 s max
Start Up Rise Time • 100 ms typical
Hold Up Time • 5 ms typical at full load and 115 VAC
Line Regulation • ±0.5% max
Load Regulation • 2% max, 0-100% load
Transient Response • 10% max. deviation, recovery to <1%
within 500 µs for a 50% step load change
at 0.2 A/µs
Ripple & Noise • See table
Overvoltage Protection • See table
Overload Protection • 120-280 %, auto recovery
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature • 0.2 %/°C
Coefficient
xppower.com
General
Efficiency • See table
Isolation • 4000 VAC Input to Output
Switching Frequency • 132 kHz typical
MTBF • 250 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • 0 °C to +70 °C, derate from 100% load at
50 °C to 50% load at 70 °C
Cooling • Natural convection
Operating Humidity • 5-90% RH, non-condensing
Storage Temperature • -20 °C to +80 °C
Vibration • 10-300 Hz, 2 g 15 mins/sweep. 30 mins
for each of 3 axes
EMC & Safety
Emissions • EN55011/22, level B conducted & radiated
Harmonic Currents • EN61000-3-2, class A
Voltage Flicker • EN61000-3-3
ESD Immunity • EN61000-4-2, ±4 kV indirect contact,
±8 kV air, Perf Criteria A
Radiated Immunity • EN61000-4-3, 3 V/m, Perf Criteria A
EFT/Burst • EN61000-4-4, level 2, Perf Criteria A
Surge • EN61000-4-5 installation class 3,
Perf Criteria A
Conducted Immunity • EN61000-4-6, 3 V, Perf Criteria A
Magnetic Field • EN61000-4-8, 1 A/m, Perf Criteria A
Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals • EN60950-1, cUL60950-1, IEC60950-1,
EN60601-1, cUL60601-1, IEC60601-1
ACDC