Headquarters: Wieland Electric GmbH Brennerstrae 10 - 14 96052 Bamberg, Germany Sales and Marketing Center: Wieland Electric GmbH Benzstrae 9 96052 Bamberg, Germany Phone +49 951 9324-0 Fax +49 951 9324-198 www.wieland-electric.com www.gesis.com info@wieland-electric.com Solutions for the control cabinet * DIN rail terminal blocks - Screw, tension spring or push-in connection technology - Wire cross sections up to 240 mm2 - Numerous special functions - Software solutions interfacing to CAE systems * Safety - Safe signal acquisition - Safety switching devices - Modular safety modules - Compact safety controllers - Applicative consultancy and training * Network engineering and fieldbus systems - Remote maintenance via VPN industrial router and VPN service portal - Industrial Ethernet switches - PLC and I/O systems, standard and increased environmental conditions * Interface - Power supply units - Overvoltage protection - Coupling relays, semiconductor switches - Timer relays, measuring and monitoring relays - Analog coupling and converter modules - Passive interfaces Solutions for field applications * Decentralized installation and automation technology - Electrical installation for wind tower - Fieldbus interfaces and motor starters * Connectors for industrial applications - Rectangular and round connectors - Aluminum or plastic housings - Degree of protection up to IP 68 - Current-carrying capacity up to 100 A - Connectors for hazardous areas - Modular, application-specific technology PC board terminals and connectors - Screw or spring clamp connection technology - Spacings: 3.5 mm to 10.16 mm - Reflow or wave soldering process interface interface Industrial technology Building and installation technology * Building installation systems - Main power supply connectors IP 20/IP 65 ... IP 68 - Bus connectors - Low-voltage connectors - Power distribution system with flat cables - Distribution systems - Bus systems in KNX, LON and radio technology - DIN rail terminal blocks for electrical installations - Overvoltage protection interface Solutions for the Control Cabinet Catalog 2013 0800.1 C 11/12 G Sales and Marketing Center in Bamberg G Company headquarters in Bamberg G STOCKO main plant in Wuppertal automation building electronics ACTIVE WORLDWIDE The Wieland Group employs more than 2,000 people all around the globe. With some 15 locations and subsidiaries, and sales partners in more than 70 countries, the Wieland Holding is present in nearly all important key markets worldwide. Always with a clear commitment to the German location where most of the products are still manufactured. 2 The group makes us strong The Wieland Holding is based in Bamberg, Bavaria, and comprises two independently acting subsidiaries: Wieland Electric and STOCKO Contact. Groundbreaking innovations made Wieland Electric one of the leading suppliers of electrical connection technology. This company, founded in Bamberg in 1910, is the largest subsidiary of the Wieland Holding. STOCKO Contact is based in Wuppertal and joined the Wieland Group in 2001. Stocko has also more than 100 years of company history to its credit and is one of the greatest manufacturers of connector systems and crimp contacts. contacts are green green Logistik contacts are Established in industries Control cabinet engineering, industrial automation, building system technology - our large product portfolio provides solutions for all kinds of applications. From innovative interface and network technology to terminal blocks to "safety first" - with modular system solutions and safety components. With Wieland products in your control cabinet, you are always on the safe side. Energy bus systems for distributed automation or indoor and outdoor field Welcome Future bus components - Wieland technology can be found everywhere, and in all kinds of applications. In building system technology, Wieland Electric is the world market leader in pluggable eletrical installation. There are good reasons why our system solutions can be found in the most spectacular building projects worldwide. When it comes to electronic networking, Wieland leads the way to the "intelligent house". Wieland Electric is 100 years young, and full of innovative energy. And our commitment for the future is not only to find constantly new system solutions for our customers but also social responsibility. Environmentally friendly high-tech products, manufactured to the latest production standards, an audited environmental management system and substantial investments in our locations are all part to this concept. Global commitment and sustainable regional action - Wieland Electric is fit for the future: Contacts are green. 3 4 Logiare Logistik stikgreen contacts Contents The Wieland Group 2 interface 6 Signal processing throughout your control system with our connectivity solutions Protect 10 wietap overvoltage protection Supply 38 wipos power supplies Pure Power - no frills Coupling 46 wienet / flare / cores always the right connection Control flare TIME Electronic and electromechanical timer and switching relays Control with the right setting 74 Measure and monitor 86 flare CONTROL Measuring and monitoring relays The right device for every monitoring task Additional product lines 92 Safety, DIN rail terminal blocks, industrial multipole connectors, cable assemblies, distributed automation Software Tools 104 Support and consultation 105 Subsidiaries and sales representatives 107 5 6 interface interface Signal processing throughout your control system, with our connectivity solutions Versatility for every application Wherever current flows and signals are processed, the unique strengths of Wieland Electric interface products shine through. Thanks to a broad range of relays, power supplies and overvoltage protection devices, as well as interface and analog modules, your application will also become a real all-rounder. Send all the right signals with our interface technology and innovative DIN rail terminal blocks. Applications: n Machine building n Process control n Transportation & material handling n Automotive industry n Power distribution n Petrochemical n Food industry n Manufacturing engineering 7 Signal processing throughout your control system with | supply | wipos power supplies including single-phase and three-phase devices for DIN rail mounting in almost any application | protection | wietap overvoltage protection devices for guaranteed highest system availability and device protection 8 interface connectivity solutions our | control | Electronic and electromechanical timer and multi-function relays flare TIME for simple to highly complex control tasks | coupling | flare relays for floating coupling of control functions. Analog isolation amplifier cores for secure coupling. Ethernet switch series and VPN industrial router wienet, for communication. | measuring and monitoring | Electronic measuring and monitoring relays flare CONTROL for all monitoring and communicating tasks in machines and systems 9 10 wietap wietap Overvoltage protection Important information on overvoltage The necessity of overvoltage protection on machines and systems as well as for building technology is ever increasing. The potential danger of damage and even complete destruction posed to valuable electronic components or even complete production systems, computer systems or communication systems by sudden overvoltage from the grid, or direct lightning strikes has mobilized not just insurance companies. Well-advised users also know the importance of protecting their electrical devices, plants and systems both sufficiently and reliably against this danger, and the overall advantage of increasing their system availability. Overvoltage protection modules Overvoltage protection modules come in three type categories which designate their capacity to absorb overvoltage energy. Type 1 arresters can divert the largest amount of energy to ground (PE). The ideal installation location for these devices is at the building's main supply. In this configuration the impulse energy is considerably weakened, if it moves downstream into the installation. In sub-panels and control cabinets, this surplus energy is reduced further by type 2 and 3 arresters, thus maintaining the survival of the protected devices. 11 Table 1 LEMP protection for buildings with electrical and electronic systems according to IEC 62305-4 (DIN EN 62305-4, DIN 0185-305-4) Lightning protection zones 12 LPZ 0A At risk from direct lightning strikes, impulse currents up to the full lightning current and through the full lightning field. LPZ 0B Protected against direct lightning strike. At risk from impulse currents up to partial lightning currents and through the full lightning field. LPZ 1 Impulse currents further limited by current division and SPDs at the zone limits. In most cases, the lightning field is attenuated by shields. LPZ 2 Impulse currents further limited by current division and SPDs at the zone limits. In most cases, the lightning field is attenuated by local shields. wietap IEC Playing it safe with overvoltage protection Very short response time and high discharge capacity With its considerably expanded wietap product range, Wieland Electric offers comprehensive solutions for overvoltage protection in control cabinets and sub panels of machines and buildings, as well as for photovoltaic systems. The components, which are modular and DIN rail mountable, range from the readyto-connect 3-phase combi-arrester wietap V M for the main distribution, to the overvoltage protection module wietap G M for sub panels, up to the overvoltage module wietap R M intended for the control cabinet or constructed into the equipment. All components are designed for application temperatures from -40 to 80 C and have a high discharge capacity. Devices are also available with a remote signaling contact. Properties of wietap: n Electrically coordinated product family n Highest discharge capacity up to 100 kA n No tripping of fuses thanks to follow current limitation n Latching pluggable protection modules n Vibration and shock tested acc. to EN 60068-2 n Visual function & defect display for every path n Modules replaceable without tools n Can also be used in front of vertical power meter 13 Surge arrester type 3 Surge arrester type 3 25 A 1) 25 A 1) 2 1 Part No. 84.995.3200.0 2 125 A 1) 315 A 1) Combined arrester type 1 L1 L2 L2 L3 R M 2P 255 FM R M 2P 255 FM PEN N/PE(N) N/PE(N) N/PE(N) N/PE(N) Surge arrester type 2 Surge arrester type 2 15 m line length to type 2 arrester neccessary 15 m line length to type 2 arrester neccessary Lightning arrester Type 1 Lightning arrester Type 1 315 A 1) 315 A 1) L1' L2 L2' L3 L3' L L' L L' L L' L3 B1 255H B1 255H B1 255H PEN Fault signal V M TNC 255 FM V M TNC 255 FM L/N 3x G S 275 Part No. 84.995.2070.0 or with remote signaling contact: 3x G S 275 FM Part No. 84.995.2090.0 B3 225 H V M TNC 255 FM L/N L/N 1x G M TNC 275 Part No. 84.995.2300.0 or with remote signaling contact: 1x G M TNC 275 FM Part No. 84.995.2305.0 L1 L1 Main distribution panel L3 R M 2P 255 FM R M 2P 255 FM sub-distribution panel L2 Fault signal 3 4 L1 Coordinated directly with type 2 and 3 arresters without additional line length Part No. 84.995.3205.0 R M 2P 255 FM 2 125 A 1) 1x R M 2P 255 FM R M 2P 255 FM 1 1x R M 2P 255 PLC 1 4 Part No. 84.995.3205.0 3 1x R M 2P 255 FM 4 L1 L2 L3 N PE 5m Measuring system R M 2P 255 Power supply unit Line length Surge arrester type 3 3 25 A 1) R M 2P 255 Control cabinet / machine L1 L2 L3 N PE 1x wietap B3 255H PEN Part. No. 84.995.0120.0 N/PE(N) N/PE(N) N/PE(N) 3x wietap B1 255H Part. No. 84.995.0222.0 PAS 1x V M TNC 255 Part No. 84.995.1300.0 alternative 1x V M TNC 255 FM Part No. 84.995.1305.0 1) Only necessary when there is no fuse with this or a smaller nominal value in the upstream system. Direct/close-up lightning strike Lightning strike into the external lightning protection, process rack (in industrial plants), cables, etc. Voltage drop of the surge grounding resistance RST Induced voltage in loops Remote lightning strike Lightning strike into medium voltage overhead lines Information technology system Figure 1 14 Low-voltage supply system Overvoltage traveling waves in overhead lines due to cloud-to-cloud lightning strikes Fields of the lightning channel wietap IEC Overvoltage protection The zone concept for lightning protection In addition to a lightning protection system in the building, additional measures for an overvoltage protection of electrical and electronic systems are required in order to safeguard the continuous availability of complex power engineering and IT systems even in the case of a direct lightning strike. It is important to consider all the causes for overvoltages. The zone concept for lightning protection enables planners, builders and owners to plan, implement and monitor protective measures. All relevant devices, plants and systems can thus be protected reliably at economically justifiable costs.. Direct or close-up lightning strikes are lightning strikes into the lightning protection system of a building, in close proximity to it, or into the electrically conductive systems implemented in the building (e.g. lowvoltage supply,telecommunications, control lines. (Fig. 1) The zone concept for lightning protection as described in IEC 62305-4 (DIN EN 62305-4, DIN 0185-305-4) applies accordingly (Fig. 3). It divides a building into different risk zones. The relevant protective measures can then be derived for each zone, especially the devices and components for lightning and overvoltage protection. Remote lightning strikes are lightning strikes that occur far away from the object to be protected as well as lightning strikes into the medium voltage overhead system or in close proximity to it, or lightning discharge from cloud to cloud (Fig. 1: cases 2a, 2b and 2c). The zones for lightning protection are defined as described in Table 1. Air terminal Waveform (s) imax. (kA) Q (AS) Room shield Ventilation WR (J/) Air terminal Standard Down conductor Low-voltage supply system Foundation ground IT system Steel armoring Equipotential bonding of lightning protection, Lightning arrester (SPD type 1)) Local equipotential bonding, Surge arrester (SPD type 2, SPD type 3) Figure 2: A Peak current for testing of lightning arresters A Peak current for testing of surge arresters Equipotential bonding of lightning protection, Lightning arrester Local equipotential bonding Surge arrester Electromagnetic lightning impulse Electromagnetic switching impulse Lightning protection zone Figure 3: EMC-oriented zone concept for lightning protection 15 wietap IEC Three-phase combined arrester, type 1 (2, 3) For protection of the building main supply wietap V M TNC 255 (FM) * Combined arrester, type 1 * For TN-C-systems * With pluggable protection modules * Max. system availability due to follow current limitation * Switch-off selective for 20 A gL/gG fuses up to 50 kA efff short-circuit current * Discharge capacity up to 75 kA (10/350) * Function/failure indication according to VDE 0100-534 * Optional with remote signaling contact (FM) * Vibration and shock tested acc. to EN 60068-2 wietap V M TNS 255 (FM) * Combined arrester Type 1 * For TN-S-systems * With pluggable protection modules * Max. system availability due to follow current limitation * Switch-off selective for 20 A gL/gG fuses up to 50 kA efff short-circuit current * Discharge capacity up to 100 kA (10/350) * Function/failure indication according to VDE 0100-534 (valid since March 2009) * Optional with remote signaling contact (FM) * Vibration and shock tested acc. to EN 60068-2 16 Type Part No. wietap V M TNC 255 wietap V M TNC 255 FM Replacement module L1, L2, L3 against e 84.995.1300.0 84.995.1305.0 84.995.1001.0 Power network SPD accord. to EN 61643-11 / IEC 61643-1 Energy-coordinated protective function to the end device Energy-coordinated protective function to the end device 5m Nominal voltage AC [UN] Nominal frequency [fN] Maximum continuous voltage AC [UC] Lightn. impulse current (10/350) [L1+L2+L3-PEN] [Itotal] Lightn. impulse current (10/350) [L-PEN] [Iimp] Nominal discharge current (8/20) [In] Protection level [UP] Follow current extinguishing capability AC [I fi] Operating time [t A] Max. pre-fusing (L) up to IK = 50 kA eff Max. pre-fusing (L) up to IK > 50 kA eff Max. pre-fusing (L-L') TOV-voltage [U T] Temperature range (Parallel wiring) [TUP] Temperature range (Through wiring) [TUS] Function/failure indication Wire range (L1, L1', L2, L2', L3, L3', PEN, e) [min.] Wire range (L1, L2, L3, PEN) [max.] Wire range (L1', L2', L3', e) [max.] Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts = Contact Type Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals TN-C Type 1 / Class I Type 1 + Typ 2 Type 1 + Type 2 + Type 3 230 / 400 V 50 / 60 Hz 255 V 75 kA 25 kA 25 / 75 kA 1.5 kV 50 kA eff 100 ns 315 A gL/gG 200 A gL/gG 125 A gL/gG 440 V / 5 sec. -40 ... +80 C -40 ... +60 C green / red 10 mm2 (AWG 8) solid/fine-stranded Type 50 mm2 (AWG 1) stranded/35 mm2 (AWG 2) fine-stranded 35 mm2 (AWG 2) stranded/25 mm2 (AWG 4) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 6 TE, DIN 43880 (108 mm) Change-over contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 16) solid/fine-stranded AoK Part No. wietap V M TNS 255 wietap V M TNS 255 FM Replacement module L1, L2, L3, N against e 84.995.1400.0 84.995.1405.0 84.995.1001.0 Power network SPD accord. to EN 61643-11 / IEC 61643-1 Energy-coordinated protective function to the end device Energy-coordinated protective function to the end device 5m Nominal voltage AC [UN] Nominal frequency [fN] Maximum continuous voltage AC [UC] Lightn. impulse current (10/350) [L1+L2+L3-PEN] [Itotal] Lightn. impulse current (10/350) [L, N-PE] [Iimp] Nominal discharge current (8/20) [In] Protection level [L, N-PE] [UP] Follow current extinguishing capability AC [I fi] Operating time [t A] Max. pre-fusing (L) up to IK = 50 kA eff Max. pre-fusing (L) up to IK > 50 kA eff Max. pre-fusing (L-L') TOV-voltage [L-N] [U T] Temperature range (Parallel wiring) [TUP] Temperature range (Through wiring) [TUS] Function/failure indication Wire range (L1, L1', L2, L2', L3, L3', N, N', PE, e) [min.] Wire range (L1, L2, L3, PE, N) [max.] Wire range (L1', L2', L3',N', e) [max.] Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts = Contact Type Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals TN-S Type 1 / Class I Type 1 + Typ 2 Type 1 + Type 2 + Type 3 230 / 400 V 50 / 60 Hz 255 V 100 kA 25 kA 25 / 100 kA 1.5 kV 50 kA eff 100 ns 315 A gL/gG 200 A gL/gG 125 A gL/gG 440 V / 5 sec. -40 ... +80 C -40 ... +60 C green / red 10 mm2 (AWG 8) solid/fine-stranded 50 mm2 (AWG 1) stranded/35 mm2 (AWG 2) fine-stranded 35 mm2 (AWG 2) stranded/25 mm2 (AWG 4) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 8 TE, DIN 43880 (144 mm) Change-over contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 16) solid/fine-stranded AoK wietap IEC Three-phase combined arrester, type 1 (2, 3) For protection of the building main supply wietap V M TT 255 (FM) * Combined arrester Type 1 * For TT- and TN-S-systems ("3+1" circuits) * With pluggable protection modules * Max. system availability due to follow current limitation * Switch-off selective for 20 A gL/gG fuses up to 50 kA efff short-circuit current * Discharge capacity up to 100 kA (10/350) * Function/failure indication according to VDE 0100-534 * Optional with remote signaling contact (FM) * Vibration and shock tested acc. to EN 60068-2 Type Part No. wietap V M TT 255 wietap V M TT 255 FM Replacement module L1, L2, L3 against N Replacement module N against e 84.995.1310.0 84.995.1315.0 84.995.1001.0 84.995.1100.0 Power network SPD according to EN 61643-11 / IEC 61643-1 Energy-coordinated protective function to the end device Energy-coordinated protective function to the end device 5m Nominal voltage AC [UN] Nominal frequency [fN] Maximum continuous voltage AC [UC] Lightn. impulse current (10/350) [L1+L2+L3 +N-PE] [Itotal] Lightn. impulse current (10/350) [L-N] [Iimp] Lightn. impulse current (10/350) [N-PE] [Iimp] Nominal discharge current (8/20) [In] Protection level [L-N, N-PE] [UP] Follow current extinguishing capability [L-N] AC [Ifi] Follow current extinguishing capability [N-PE] AC [I fi] Operating time [t A] Max. pre-fusing (L) up to IK = 50 kA eff Max. pre-fusing (L) up to IK > 50 kA eff Max. pre-fusing (L-L') TOV-voltage [L-N] [U T] TOV-voltage [N-PE] [U T] Temperature range (Parallel wiring) [TUP] Temperature range (Through wiring) [TUS] Function/failure indication Wire range (L1, L1', L2, L2', L3, L3', N, N', PE, e) [min.] Wire range (L1, L2, L3, N, PE) [max.] Wire range (L1', L2', L3', N, e) [max.] Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts = Contact Type Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals TT and TN-S Type 1 / Class I Type 1 + Typ 2 Type 1 + Type 2 + Type 3 230 / 400 V 50 / 60 Hz 255 V 100 kA 25 kA 100 kA 25 / 100 kA 1.5 kV 50 kA eff 100 A eff 100 ns 315 A gL/gG 200 A gL/gG 125 A gL/gG 440 V / 5 sec. 1200 V / 200 ms -40 ... +80 C -40 ... +60 C green / red 10 mm2 (AWG 8) solid/fine-stranded 50 mm2 (AWG 1) stranded/35 mm2 (AWG 2) fine-stranded 35 mm2 (AWG 2) stranded/25 mm2 (AWG 4) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 8 TE, DIN 43880 (144 mm) Change-over contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 16) solid/fine-stranded AoK Replacement module for wietap VM devices wietap V MOD 255 Type Part No. Network spark gap protection module for all L - e; L - N and for wietap V M TNS 255 (FM) N-e wietap V MOD 255 84.995.1001.0 wietap V MOD NPE 100 wietap V MOD NPE 100 84.995.1100.0 Network spark gap protection module for wietap V M TT 255 (FM) N-e 17 wietap IEC 3-phase lightning arrester, type 1 For protection of the building main supply Type wietap B3 255H wietap B3 255H * Lightning arrester, type 1 * For all systems (in connection with wietap GPM 255 if required) * High limitation of follow current * 50 kA discharge capacity per pole * High insulation resistance; can therefore also be placed in front of the meter * Double terminals for V connection L1 L2 Technical Data SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Nominal voltage AC [UN] Maximum continuous voltage AC [UC] Lightn. impulse current (10/350) [L-N/PEN] [Iimp] Lightn. impulse current (10/350) [L1+L2+L3-N/ PEN] [Itotal] Nominal discharge current (8/20) [In] Protection level [UP] Follow current extinguishing capability AC [Ifi] Limitation of follow current / selectivity Type 1 Class I 230/400 V 255 V 50 kA 100 kA Operating time [t A] Max. pre-fusing bis IK = 50 kAeff (ta 0,2 s) Max. pre-fusing bis IK = 50 kAeff (ta 5 s) Max. pre-fusing bei IK > 50 kAeff Max. pre-fusing (L-L) TOV-voltage [U T] Temperature range (Parallel wiring) [TUP] Temperature range (Through wiring) [TUS] -40 ... +60 C Wire range (L1, L2, L3, N/PEN) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Approvals N/PEN 84.995.0120.0 50 / 100 kA 4 kV 50 kAeff Non-tripping of a 35 A gL/gG fuse up to 50 kAeff (prosp.) 100 ns 500 A gL/gG 315 A gL/gG 200 A gL/gG 125 A gL/gG 335 V / 5 sec. -40 ... +80 C Wire range (L1, L1, L2, L2, L3, L3, N/PEN, N/ PEN) Wire range (L1, L2, L3, N/PEN) L3 Part No. 10 mm (AWG 8) solid/fine-stranded 50 mm (AWG 1) stranded / 35 mm (AWG 2) fine-stranded 35 mm (AWG 2) stranded / 25 mm (AWG 4) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 6 TE, DIN 43880 (108 mm) Ao 1-phase lightning arrester, type 1 For the protection of the building main supply Type wietap B1 255H wietap B1 255H * Lightning arrester, type 1 * For all systems (in connection with wietap GPM 255 if required) * High limitation of follow current * 50 kA discharge capacity per pole * High insulation resistance; can therefore also be placed in front of the meter * Double terminals for V connection L L Technical Data SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Nominal voltage ac [UN] Maximum continuous voltage AC [UC] Lightn. impulse current (10/350) [Iimp] Nominal discharge current (8/20) [In] Protection level [UP] Follow current extinguishing capability AC [Ifi] Limitation of follow current / selectivity Operating time [t A] Max. pre-fusing bis IK = 50 kAeff (ta 0,2 s) Max. pre-fusing bis IK = 50 kAeff (ta 5 s) Max. pre-fusing bei IK > 50 kAeff Max. pre-fusing (L-L) TOV-voltage [U T] Temperature range (Parallel wiring) [TUP] Temperature range (Through wiring) [TUS] -40 ... +60 C Wire range (L, L, N/PEN, N/PEN) [min.] 10 mm (AWG 8) solid/fine-stranded Wire range (L, N/PEN) [max.] 50 mm (AWG 1) stranded / 35 mm (AWG 2) fine-stranded 35 mm (AWG 2) stranded / 25 mm (AWG 4) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 2 TE, DIN 43880 (36 mm) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Approvals 18 84.995.0222.0 Type 1 Class I 230 V 255 V 50 kA 50 kA 4 kV 50 kA eff Non-tripping of a 35 A gL/gG fuse up to 50 kAeff (prosp.) 100 ns 500 A gL/gG 315 A gL/gG 200 A gL/gG 125 A gL/gG 335 V / 5 sec. -40 ... +80 C Wire range (L, N/PEN) [max.] N/PEN N/PEN Part No. Ao wietap IEC N-PE lightning arrester, type 1 For protection of the building main supply Type wietap GMP 255 * N-PE lightning arrester, type 1 * In combination with wietap B1 255H or wietap B3 255H * 100 kA discharge capacity N N wietap GPM 255 84.995.0055.0 Technical Data SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Maximum continuous voltage AC [UC] Lightn. impulse current (10/350) [limp] Nominal discharge current (8/20) [In] Protection level [UP] Follow current extinguishing capability AC [l fi] Operating time [t a] TOV-voltage Temperature range (Parallel wiring) [TUP] Type 1 Class I 255 V 100 kA 100 kA 1.5 kV 100 Aeff 100 ns 1200 V / 200 ms -40 ... +80 C Temperature range (Through wiring) [TUS] -40 ... +60 C Function/failure indication Wire range (min.) green / red 10 mm (AWG 8) solid/fine-stranded 50 mm (AWG 1) stranded / 35 mm (AWG 2) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 2 TE, DIN 43880 (36 mm) Wire range (max.) NPE Part No. Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Approvals Ao N 19 wietap IEC Three-phase combined arrester, type 2 For protection of sub-distributions or the control cabinet main supply wietap G M TNC 275 (FM) * Surge arrester, type 2 * For TN-C-systems * With pluggable protection modules * Function/failure indication according to VDE 0100-534 * Optional with remote signaling contact (FM) * Vibration and shock tested acc. to EN 60068-2 Type wietap G M TNC 275 wietap G M TNC 275 FM Replacement module L1, L2, L3 against e 84.995.2300.0 84.995.2305.0 84.995.2010.0 Power network SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Nominal voltage AC [UN] Nominal frequency [fN] Maximum continuous voltage AC [UC] Nominal discharge current (8/20) [In] Max. discharge current (8/20) [Imax] Protection level [UP] Protection level at 5 kA [UP] Operating time [t A] Maximum network overcurrent protection Short-circuit proof with max. network overcurrent protection TOV-voltage [U T] Temperature range [TU] Function/failure indication Wire range (min.) Wire range (max.) TN-C Type 2 Class II 230/400 V 50 / 60 Hz 275 V 20 kA 40 kA 1.25 kV 1 kV 25 ns 125 A gL/gG 50 kA eff Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts = Contact Type Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals wietap G M TNS 275 (FM) * Surge arrester, type 2 * For TN-S-systems * With pluggable protection modules * Function/failure indication according to VDE 0100-534 * Optional with remote signaling contact (FM) * Vibration and shock tested acc. to EN 60068-2 Type 335 V / 5 sec. -40 ... +80 C green / red 1.5 mm2 (AWG 14) solid/fine-stranded 35 mm2 (AWG 2) stranded / 25 mm2 (AWG 4) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 3 TE, DIN 43880 (54 mm) Change-over contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 14) solid/fine-stranded AoK Part No. wietap G M TNS 275 wietap G M TNS 275 FM Replacement module L1, L2, L3, N against e 84.995.2400.0 84.995.2405.0 84.995.2010.0 Power network SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Nominal voltage AC [UN] Nominal frequency [fN] Maximum continuous voltage AC [UC] Nominal discharge current (8/20) [In] Max. discharge current (8/20) [Imax] Protection level [UP] Protection level at 5 kA [UP] Operating time [t A] Maximum network overcurrent protection Short-circuit proof with max. network overcurrent protection TOV-voltage [U T] Temperature range [TU] Function/failure indication Wire range (min.) Wire range (max.) TN-S Type 2 Class II 230/400 V 50 / 60 Hz 275 V 20 kA 40 kA 1.25 kV 1 kV 25 ns 125 A gL/gG 50 kA eff Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts = Contact Type Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals 20 Part No. 335 V / 5 sec. -40 ... +80 C green / red 1.5 mm2 (AWG 14) solid/fine-stranded 35 mm2 (AWG 2) stranded / 25 mm2 (AWG 4) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 4 TE, DIN 43880 (72 mm) Change-over contact 250 V/ 0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 14) solid/fine-stranded AoK wietap IEC Three-phase combined arrester, type 2 For protection of sub-distributions or the control cabinet main supply wietap G M TT 275 (FM) * Surge arrester, type 2 * For TT- and TN-S-systems ("3+1" circuits) * With pluggable protection modules * Function/failure indication according to VDE 0100-534 * Optional with remote signaling contact (FM) * Vibration and shock tested acc. to EN 60068-2 Type Part No. wietap G M TT 275 wietap G M TT 275 FM Replacement module L1, L2, L3 against N Replacement module N against e 84.995.2310.0 84.995.2315.0 84.995.2010.0 84.995.2050.0 Power network SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Nominal voltage AC [UN] Nominal frequency [fN] Maximum continuous voltage AC [L-N] [UC] Maximum continuous voltage AC [N-PE] [UC] Nominal discharge current (8/20) [In] Max. discharge current (8/20) [I max] Lightn. impulse current (10/350) [N-PE] [Iimp] Protection level [L-N] [UP] Protection level [L-N] at 5 kA [UP] Protection level [N-PE] [UP] Follow current extinguishing capability [N-PE] [I fi] Operating time [L-N] [t A] Operating time [N-PE] [t A] Maximum network overcurrent protection Short-circuit proof with network overcurrent protection with 25 A gL/gG TOV-voltage [L-N] U T] TOV-voltage [N-PE] [U T] Temperature range [TU] Function/failure indication Wire range (min.) Wire range (max.) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts = Contact Type Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals TT and TN-S (Variante 3+1") Type 2 Class II 230/400 V 50 / 60 Hz 275 V 255 V 20 kA 40 kA 12 kA 1.25 kV 1 kV 1.5 kV 100 A eff 25 ns 100 ns 125 A gL/gG 50 kA eff 335 V / 5 sec. 1200 V / 200 ms -40 ... +80 C green / red 1.5 mm2 (AWG 14) solid/fine-stranded 35 mm2 (AWG 2) stranded / 25 mm2 (AWG 4) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 4 TE, DIN 43880 (72 mm) Change-over contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 14) solid/fine-stranded AoK Replacement module for wietap G M devices wietap G MOD 275 Type Part No. Varistor protection module for all L - e; L - N and for wietap G M TNS 275 (FM) N-e wietap G MOD 275 84.995.2010.0 wietap G MOD NPE wietap G MOD NPE 84.995.2050.0 Spark gap protection module for N - e and for wietap G M TT 275 (FM) N-e 21 wietap IEC Single-phase surge arrester, type 2 For protection of sub-distributions or the control cabinet main supply wietap G S 275 (FM) * Surge arrester, type 2 * All-purpose surge arrester * With pluggable protection modules * High discharge capacity due to powerful zinc oxid varistor * High reliability due to arrester monitoring * Slim design (modular construction) acc. to DIN 43880 * Multi-function connection for conductors and comb rails * Function/failure indication according to VDE 0100-534 * Optional with remote signaling contact (FM) * Vibration and shock tested acc. to EN 60068-2 Type wietap G S 275 wietap G S 275 FM 84.995.2070.0 84.995.2090.0 Power network SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Maximum continuous voltage AC [UC] Nominal frequency [fN] Maximum continuous voltage DC [UC] Nominal discharge current (8/20) [In] Max. discharge current (8/20) [Imax] Protection level [UP] Protection level at 5 kA [UP] Operating time [t A] Maximum network overcurrent protection Short-circuit proof with max. network overcurrent protection TOV-voltage [U T] Temperature range [TU] Function/failure indication Wire range (min.) Wire range (max.) universal Type 2 Class II 275 V 50 / 60 Hz 350 V 20 kA 40 kA 1.25 kV 1 kV 25 ns 125 A gL/gG 50 kA eff Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts = Contact Type Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals wietap G MOD 275 * Replacement module for wietap G S 275 (FM) 22 Part No. Type wietap G MOD 275 335 V / 5 sec. -40 ... +80 C green / red 1.5 mm2 (AWG 14) solid/fine-stranded 35 mm2 (AWG 2) stranded / 25 mm2 (AWG 4) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 1 TE, DIN 43880 (18 mm) Change-over contact 250 V/0,5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 14) solid/fine-stranded AoK Part No. 84.995.2010.0 wietap IEC Single-phase surge arrester, type 2 For protection of sub-distributions or the control cabinet main supply wietap GP C S (FM) * Surge arrester, type 2 * For use in TT systems in "3+1" and "1+1" circuits acc. to E DIN VDE 0100-534 between neutral conductor N and protective conductor PE * High discharge capacity * With pluggable protection modules * Function/failure indication according to VDE 0100-534 * Optional with remote signaling contact (FM) * Vibration and shock tested acc. to EN 60068-2 Type wietap GP C S wietap GP C S FM 84.995.2030.0 84.995.2035.0 Power network SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Maximum continuous voltage AC [UC] Nominal frequency [fN] Nominal discharge current (8/20) [In] Max. discharge current (8/20) [I max] Follow current extinguishing capability [I fi] Lightn. impulse current (10/350) [Iimp] Protection level [UP] Operating time [t A] TOV-voltage [U T] Temperature range [TU] Function/failure indication Wire range (min.) Wire range (max.) TT Type 2 Class II 255 V 50 / 60 Hz 20 kA 40 kA 100 A eff 12 kA 1.5 kV 100 ns 1200 V / 200 ms -40 ... +80 C green / red 1.5 mm2 (AWG 14) solid/fine-stranded 35 mm2 (AWG 2) stranded / 25 mm2 (AWG 4) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 1 TE, DIN 43880 (18 mm) Change-over contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 14) solid/fine-stranded Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts = Contact Type Switching capacity AC(FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals wietap GP C MOD * Replacement module for wietap G CS (FM) Part No. Type wietap GP C MOD AoK Part No. 84.995.2060.0 23 wietap IEC Surge arrester, type 3 For direct load protection in control cabinets or sub-distributions wietap R M 2P 30 FM wietap R M 2P 255 (FM) * Surge arrester, type 3 * Two-pole surge arrester * High discharge capacity due to powerful zinc oxide varistor * Slim design (modular construction) acc. to DIN 43880 * With pluggable protection modules * Function/failure indication according to VDE 0100-534 * Optional with remote signaling contact (FM) * Vibration and shock tested acc. to EN 60068-2 wietap R MOD 255 * Replacement module for wietap R M 2P 255 (FM) 24 Type wietap R M 2P 30 FM wietap R M 2P 255 wietap R M 2P 255 FM SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Nominal voltage AC [UN] Maximum continuous voltage AC [UC] Maximum continuous voltage DC [UC] Nominal load current AC [IL] Nominal discharge current (8/20) [In] Total discharge current (8/20) [L+N-PE] [Itotal] Combined surge [UOC] Combined surge [L+N-PE] [UOC total] Protection level [L-N] [UP] Protection level [L/N-PE] [UP] Operating time [L-N] [t A] Operating time [L/N-PE] [t A] Maximum network overcurrent protection Short-circuit proof with network overcurrent protection with 25 A gL/gG TOV-voltage [L-N] [UT] TOV-voltage [L/N-PE] (I) [U T] TOV-voltage [L+N-PE] (II) [U T] Temperature range [TU] Function/failure indication Wire range min. Wire range max. Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts = Contact Type Switching capacity AC (FM) Switching capacity DC (FM) Wire range for Remote signaling terminals Approvals Type wietap R MOD 255 Part No. Part No. 84.995.3206.0 84.995.3200.0 84.995.3205.0 Type 3 Class III 230 V 255 V 255 V 25 A 3 kA 5 kA 6 kV 10 kV 1250 V 1500 V 25 ns 100 ns 25 A gL/gG oder B 25 A 6 kA rms Type 3 Category A / Class III 24 V 30 V 30 V 25 A 1 kA 2 kA 2 kV 4 kV 180 V 630 V 25 ns 100 ns 25 A gL/gG or B 25 A 6 kArms 335 V / 5 sec. -400 V / 5 sec. -1200 V + UO / 200 ms --40 ... +80 C green / red 0.5 mm2 (AWG 20) solid/fine-stranded 4 mm2 (AWG 12) solid / 2.5 mm2 (AWG 14) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 1 TE, DIN 43880 (18 mm) Change-over contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 16) solid/fine-stranded AoKw Part No. 84.995.3010.0 wietap IEC Surge arrester, type 3 For direct load protection in control cabinets or sub-distributions wietap R M 4P 255 (FM) Type wietap R M 4P 255 wietap R M 4P 255 FM * Surge arrester, type 3 * Four-pole surge arrester * High discharge capacity due to powerful zinc oxide varistor * Slim design (modular construction) acc. to DIN 43880 * With pluggable protection modules * Function/failure indication according to VDE 0100-534 * Optional with remote signaling contact (FM) * Vibration and shock tested acc. to EN 60068-2 Technical Data SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Nominal voltage AC [UN] Maximum continuous voltage AC [UC] Nominal load current AC [IL] Nominal discharge current (8/20) [In] Total discharge current (8/20) [L+N-PE] [Itotal] Combined surge [UOC] Combined surge [L+N-PE] [UOC total] Protection level [L-N] [UP] Protection level [L/N-PE] [UP] Operating time [L-N] [t A] Operating time [L/N-PE] [t A] Maximum network overcurrent protection Short-circuit proof with network overcurrent protection with 25 A gL/gG TOV-voltage [L-N] [U T] TOV-voltage [L/N-PE] (I) [U T] TOV-voltage [L+N-PE] (II) [U T] Temperature range [TU] Function/failure indication Wire range (min.) Wire range (max.) Mounted on DIN rail acc. to EN 60715 Housingwerkstoff Degree of protection Dimensions Remote signaling contacts = Contact Type Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals 12 11 14 L1 L1 L2 L2 L3 L3 PE PE N N wietap R M MOD 4P 255 * Replacement module for wietap R M 4P 255 Type wietap R M MOD 4P 255 Part No. 84.995.3400.0 84.995.3405.0 Type 3 Class III 230/400 V 255/440 V 25 A 3 kA 8 kA 6 kV 16 kV 1000 V 1500 V 25 ns 100 ns 25 A gL/gG oder B 25 A 6 kAeff 335 V / 5 sec. 400 V / 5 sec. 1200 V + U0 / 200 ms -40 ... +80 C green / red 0.5 mm (AWG 20) solid/fine-stranded 4 mm (AWG 12) solid / 2.5 mm (AWG 14) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 2 TE, DIN 43880 (36 mm) Change-over contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 16) solid/fine-stranded AoK Part No. 84.995.3020.0 25 Solutions for Category B for the different mains systems: Selection Matrix Circuit 26 Circuit Voltage Configuration Used Types Connected between 120/240V Split Phase 1O 3W + Grnd wietap G S 150 FM UL wietap G S 150 FM UL L1 Phase-Grnd L2 Phase-Grnd 240/480V Split Phase 1O 3W + Grnd wietap G S 320 FM UL wietap G S 320 FM UL L1 Phase-Grnd L2 Phase-Grnd 127/254V Split Phase 1O 3W + Grnd wietap G S 150 FM UL wietap G S 150 FM UL L1 Phase-Grnd L2 Phase-Grnd 120/208V Wye 3O 3W + Grnd wietap G S 150 FM UL wietap G S 150 FM UL wietap G S 150 FM UL L1 Phase-Grnd L2 Phase-Grnd L3 Phase-Grnd 277/480V Wye 3O 3W + Grnd wietap G S 320 FM UL wietap G S 320 FM UL wietap G S 320 FM UL L1 Phase-Grnd L2 Phase-Grnd L3 Phase-Grnd 347/600V Wye 3O 3W + Grnd wietap G S 440 FM UL wietap G S 440 FM UL wietap G S 440 FM UL L1 Phase-Grnd L2 Phase-Grnd L3 Phase-Grnd 120/208V Wye 3O 4W + Grnd wietap G S 150 FM UL wietap G S 150 FM UL wietap G S 150 FM UL wietap G S 150 FM UL L1 Phase-Grnd L2 Phase-Grnd L3 Phase-Grnd Neutral-Grnd 277/480V Wye 3O 4W + Grnd wietap G S 320 FM UL wietap G S 320 FM UL wietap G S 320 FM UL wietap G S 320 FM UL L1 Phase-Grnd L2 Phase-Grnd L3 Phase-Grnd Neutral-Grnd 347/600V Wye 3O 4W + Grnd wietap G S 440 FM UL wietap G S 440 FM UL wietap G S 440 FM UL wietap G S 440 FM UL L1 Phase-Grnd L2 Phase-Grnd L3 Phase-Grnd Neutral-Grnd 127/220V Wye 3O 4W + Grnd wietap G S 150 FM UL wietap G S 150 FM UL wietap G S 150 FM UL wietap G S 150 FM UL L1 Phase-Grnd L2 Phase-Grnd L3 Phase-Grnd Neutral-Grnd 120/240V High Leg Delta - B High wietap G S 150 FM UL wietap G S 150 FM UL wietap G S 150 FM UL wietap G S 275 FM UL L1 Phase-Neutral L3 Phase-Neutral Neutral-Grnd L2 Phase-Neutral 240/480V High Leg Delta - B High wietap G S 320 FM UL wietap G S 320 FM UL wietap G S 320 FM UL wietap G S 600 FM UL L1 Phase-Neutral L3 Phase-Neutral Neutral-Grnd L2 Phase-Neutral 480V Delta 3O 3W + Grnd & HRG Wye wietap G S 600 FM UL wietap G S 600 FM UL wietap G S 600 FM UL L1 Phase-Grnd L2 Phase-Grnd L3 Phase-Grnd 240V Delta 3O 3W + Grnd wietap G S 320 FM UL wietap G S 320 FM UL wietap G S 320 FM UL L1 Phase-Grnd L2 Phase-Grnd L3 Phase-Grnd 600V Delta 3O 3W + Grnd & HRG wietap G S WE 600 FM UL wietap G S WE 600 FM UL wietap G S WE 600 FM UL L1 Phase-Grnd L2 Phase-Grnd L3 Phase-Grnd 120V Single Phase wietap G S 150 FM UL L1 Phase-Neutral 240V Single Phase wietap G S 320 FM UL L1 Phase-Neutral 127V Single Phase wietap G S 150 FM UL L1 Phase-Neutral 254V Single Phase wietap G S 320 FM UL L1 Phase-Neutral 347V Single Phase wietap G S 440 FM UL L1 Phase-Neutral 277V Single Phase wietap G S 320 FM UL L1 Phase-Neutral 480V Single Phase wietap G S 600 FM UL L1 Phase-Neutral 600V Single Phase wietap G S WE 600 FM UL L1 Phase-Neutral 480V B Corner Grnd Delta 3O 3W + Grnd wietap G S 600 FM UL wietap G S 600 FM UL L1 Phase-Grnd L3 Phase-Grnd 240V B Corner Grnd Delta 3O 3W + Grnd wietap G S 320 FM UL wietap G S 320 FM UL L1 Phase-Grnd L3 Phase-Grnd 600V B Corner Grnd Delta 3O 3W + Grnd wietap G S WE 600 FM UL wietap G S WE 600 FM UL L1 Phase-Grnd L3 Phase-Grnd wietap UL / CSA Overvoltage Protection for North and Central For the North and Central American region OVP modules have to be used with UL or CSA approval. At the same time the voltage levels are different compared to Europe or the Asian region. For this reason Wieland offers specialized OVP modules. The green marked countries have energy network systems according UL and CSA mains systems and voltage levels. America The overvoltage protection according IEEE is defined into 3 different areas: n Category C (Class I according IEC): is mainly used at the feed in point of a building or production site. Mainly at outside termination n Category B (Class II according IEC): this category is often used inside of buildings in main distribution panels or in switch board cabinets of machines n Category A (Class III according IEC): is mainly used for the protection of single devices inside a switch board cabinet Wieland is offering solutions for inside the building. This means for Category B and Category A. 3 4 R M 2P 255 PLC At Category A applications the arrester is connected up front in series to the device. The rated voltage of the OVP is selected according the nominal voltage of the device which is connected. 1 2 Category A 27 wietap UL / CSA Single-phase surge arrester, category B & A For protection of sub-distributions or the control cabinet main supply wietap G S 150 FM UL wietap G S 275 FM UL * Surge arrester, type 2, category B * Multi-purpose surge arrester * With plug-in protection module * Thermo Dynamic Control SPD monitoring device * Small housing * Operating state/fault indication by indicator flag in window * With signaling contact (FM) * Vibration and shock tested according EN 60068-2 12 11 14 wietap G S 320 FM UL wietap G S 385 FM UL * Surge arrester, type 2, category B * Multi-purpose surge arrester * With plug-in protection module * Thermo Dynamic Control SPD monitoring device * Small housing * Operating state/fault indication by indicator flag in window * With signaling contact (FM) * Vibration and shock tested according EN 60068-2 12 11 14 28 Type Part No. Part No. wietap G S 150 FM UL wietap G S 275 FM UL 84.995.2092.1 SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Maximum continuous voltage AC [UC] Maximum continuous voltage DC [UC] Rated varistor voltage AC [Umov] Rated voltage (50/60 Hz) [V] Max. continuous operating voltage [MCOV] Voltage protection rating [VPR] Rated discharge current [In] Max. discharge current (8/20) [Imax] Protection level [UP] Protection level at 5 kA [UP] Operating time [t A] Maximum network overcurrent protection Short-circuit proof with max. network overcurrent protection TOV-voltage [UT] Temperature range [TU] acc. to UL 1449 3rd edition acc. to EN 61643-11 Function/failure indication Wire range (min.) Wire range (max.) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts (FM) Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals Type 2 Category B / Class II 150 V 200 V 200 V 150 V 150 V 700 V 20 kA 40 kA 0.7 kV 0.55 kV 25 ns 125 A gL/gG 50 kArms Type 2 Category B / Class II 275 V 350 V 350 V 275 V 275 V 1000 V 20 kA 40 kA 1.25 kV 1 kV 25 ns 125 A gL/gG 50 kArms 175 V / 5 sec. 335 V / 5 sec. Type 84.995.2090.1 0... +85 C -40... +85 C green / red 1.5 mm2 (AWG 14) solid/fine-stranded 35 mm2 (AWG 2) stranded / 25 mm2 (AWG 4) fine-stranded 35 mm thermoplastic, UL 94 V-0 IP 20 1 mod., DIN 43880 changeover contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 14) solid/fine-stranded A Kw Part No. Part No. wietap G S 320 FM UL wietap G S 385 FM UL 84.995.2093.1 SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Maximum continuous voltage AC [UC] Maximum continuous voltage DC [UC] Rated varistor voltage AC [Umov] Rated voltage (50/60 Hz) [V] Max. continuous operating voltage [MCOV] Voltage protection rating [VPR] Rated discharge current [In] Max. discharge current (8/20) [Imax] Protection level [UP] Protection level at 5 kA [UP] Operating time [t A] Maximum network overcurrent protection Short-circuit proof with max. network overcurrent protection TOV-voltage [UT] Temperature range [TU] acc. to UL 1449 3rd edition acc. to EN 61643-11 Function/failure indication Wire range (min.) Wire range (max.) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts (FM) Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals Type 2 Category B / Class II 320 V 420 V 420 V 320 V 320 V 1200 V 20 kA 40 kA 1.5 kV 1.2 kV 25 ns 125 A gL/gG 25 kArms Type 2 Category B / Class II 385 V 500 V 500 V 385 V 385 V 1500 V 20 kA 40 kA 1.75 kV 1.35 kV 25 ns 125 A gL/gG 25 kArms 335 V / 5 sec. 385 V / 5 sec. 84.995.2094.1 0... +85 C -40... +85 C green / red 1.5 mm2 (AWG 14) solid/fine-stranded 35 mm2 (AWG 2) stranded / 25 mm2 (AWG 4) fine-stranded 35 mm thermoplastic, UL 94 V-0 IP 20 1 mod., DIN 43880 changeover contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 14) solid/fine-stranded A L Kw wietap UL / CSA Single-phase surge arrester, category B & A For protection of sub-distributions or the control cabinet main supply wietap G S 440 FM UL wietap G S 600 FM UL * Surge arrester, type 2, category B * Multi-purpose surge arrester * With plug-in protection module * Thermo Dynamic Control SPD monitoring device * Small housing * Operating state/fault indication by indicator flag in window * With signaling contact (FM) * Vibration and shock tested according EN 60068-2 12 11 14 wietap G S WE 600 FM UL Type Part No. Part No. wietap G S 440 FM UL wietap G S 600 FM UL 84.995.2095.1 SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Maximum continuous voltage AC [UC] Maximum continuous voltage DC [UC] Rated varistor voltage AC [Umov] Rated voltage (50/60 Hz) [V] Max. continuous operating voltage [MCOV] Voltage protection rating [VPR] Rated discharge current [In] Max. discharge current (8/20) [Imax] Protection level [UP] Protection level at 5 kA [UP] Operating time [t A] Maximum network overcurrent protection Short-circuit proof with max. network overcurrent protection TOV-voltage [UT] Temperature range [TU] acc. to UL 1449 3rd edition acc. to EN 61643-11 Function/failure indication Wire range (min.) Wire range (max.) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts (FM) Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals Type 2 Category B / Class II 440 V 585 V 585 V 440 V 440 V 1500 V 20 kA 40 kA 2 kV 1.7 kV 25 ns 125 A gL/gG 25 kArms Type 2 Category B / Class II 600 V 600 V 600 V 600 V 600 V 2000 V 20 kA 30 kA 2.5 kV 2 kV 25 ns 100 A gL/gG 25 kArms 580 V / 5 sec. 600 V / 5 sec. Type 84.995.2096.1 0... +85 C -40... +85 C green / red 1.5 mm2 (AWG 14) solid/fine-stranded 35 mm2 (AWG 2) stranded / 25 mm2 (AWG 4) fine-stranded 35 mm thermoplastic, UL 94 V-0 IP 20 1 mod., DIN 43880 changeover contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 14) solid/fine-stranded A Kw Part No. wietap G S WE 600 FM UL 84.995.2097.1 SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Maximum continuous voltage AC [UC] Maximum continuous voltage DC [UC] Rated varistor voltage AC [Umov] Rated voltage (50/60 Hz) [V] Max. continuous operating voltage [MCOV] Voltage protection rating [VPR] Rated discharge current [In] Max. discharge current (8/20) [Imax] Protection level [UP] Protection level at 5 kA [UP] Operating time [t A] Maximum network overcurrent protection Short-circuit proof with max. network overcurrent protection TOV-voltage [UT] Temperature range [TU] acc. to UL 1449 3rd edition acc. to EN 61643-11 Function/failure indication Wire range (min.) Wire range (max.) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts (FM) Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals Type 2 Category B / Class II 600 V 600 V 750V 600 V 750 V 2500V 10 kA 25 kA 3 kV 2.5 kV 25 ns 100 A gL/gG 25 kArms Part No. * Surge arrester, type 2, category B * Multi-purpose surge arrester * With plug-in protection module * Thermo Dynamic Control SPD monitoring device * Small housing * Operating state/fault indication by indicator flag in window * With signaling contact (FM) * Vibration and shock tested according EN 60068-2 12 11 14 900 V / 5 sec. 0... +85 C -40... +85 C green / red 1.5 mm2 (AWG 14) solid/fine-stranded 35 mm2 (AWG 2) stranded / 25 mm2 (AWG 4) fine-stranded 35 mm thermoplastic, UL 94 V-0 IP 20 1 mod., DIN 43880 changeover contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 14) solid/fine-stranded A Kw 29 wietap UL / CSA Surge arrester, category A For direct load protection in control cabinets or sub-distributions Type wietap R M 2P 30 FM wietap R M 2P 30 FM * Surge arrester, type 3 * Two-pole surge arrester * High discharge capacity due to powerful zinc oxide varistor * Slim design (modular construction) acc. to DIN 43880 * With pluggable protection modules * Function/failure indication according to VDE 0100-534 * With remote signaling contact (FM) 12 11 14 3 1 4 2 * Vibration and shock tested acc. to EN 60068-2 Type wietap R M 2P 150 FM wietap R M 2P 150 FM * Surge arrester, type 3 * Two-pole surge arrester * High discharge capacity due to powerful zinc oxide varistor * Slim design (modular construction) acc. to DIN 43880 * With pluggable protection modules * Function/failure indication according to VDE 0100-534 * With remote signaling contact (FM) 12 11 14 3 1 4 2 * Vibration and shock tested acc. to EN 60068-2 30 Technical Data SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Rated voltage (50/60 Hz) [V] Maximum continuous voltage AC [UC] Maximum continuous voltage DC [UC] Max. continuous operating voltage [MCOV] Voltage protection rating [VPR] Rated current AC acc. UL 1449 3rd edition | EN 61643-11 Rated discharge current (8/20) [In] Total discharge current (8/20) [L+N-PE] [Itotal] Combined surge [UOC] Combined surge [L+N-PE] [UOC total] Protection level [L-N] [UP] Protection level [L/N-PE] [UP] Operating time [L-N] [t A] Operating time [L/N-PE] [t A] Maximum network overcurrent protection Short-circuit proof with network overcurrent protection with 25 A gL/gG Temperature range [TU] acc. to UL 1449 3rd edition acc. to EN 61643-11 Function/failure indication Wire range (min.) Wire range (max.) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts (FM) Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals Technical Data SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Rated voltage (50/60 Hz) Maximum continuous voltage AC [UC] Maximum continuous voltage DC [UC] Max. continuous operating voltage [MCOV] Voltage protection rating [VPR] Rated current AC acc. UL 1449 3rd edition | EN 61643-11 Rated discharge current (8/20) [In] Total discharge current (8/20) [L+N-PE] [Itotal] Combined surge [UOC] Combined surge [L+N-PE] [UOC total] Protection level [L-N] [UP] Protection level [L/N-PE] [UP] Operating time [L-N] [t A] Operating time [L/N-PE] [t A] Maximum network overcurrent protection Short-circuit proof with network overcurrent protection with 25 A gL/gG Temperature range [TU] acc. to UL 1449 3rd edition acc. to EN 61643-11 Function/failure indication Wire range (min.) Wire range (max.) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts (FM) Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals Part No. 84.995.3206.0 Type 3 Category A / Class III 24 V 30 V 30 V 30 V 330 V 20 A | 25 A 1 kA 2 kA 2 kV 4 kV 180 V 630 V 25 ns 100 ns 25 A gL/gG or B 25 A 6 kArms 0... +85 C -40... +85 C green / red 0.5 mm (AWG 20) solid/fine-stranded 4 mm (AWG 12) solid / 2.5 mm (AWG 14) fine-stranded 35 mm thermoplastic, UL 94 V-0 IP 20 1 mod., DIN 43880 changeover contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 16) solid/fine-stranded A Kw Part No. 84.995.3209.0 Type 3 Category A / Class III 120 V 150 V 150 V 150 V 700 V 20 A | 25 A 2 kA 4 kA 4 kV 8 kV 640 V 800 V 25 ns 100 ns 25 A gL/gG or B 25 A 6 kArms 0... +85 C -40... +85 C green / red 0.5 mm (AWG 20) solid/fine-stranded 4 mm (AWG 12) solid / 2.5 mm (AWG 14) fine-stranded 35 mm thermoplastic, UL 94 V-0 IP 20 1 mod., DIN 43880 changeover contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 14) solid/fine-stranded A Kw wietap UL / CSA Surge arrester, category A For direct load protection in control cabinets or sub-distributions wietap R M 2P 255 * Surge arrester, type 3 * Two-pole surge arrester * High discharge capacity due to powerful zinc oxide varistor * Slim design (modular construction) acc. to DIN 43880 * With pluggable protection modules * Function/failure indication according to VDE 0100-534 * Vibration and shock tested acc. to EN 60068-2 wietap R M 2P 255 FM * Surge arrester, type 3 * Two-pole surge arrester * High discharge capacity due to powerful zinc oxide varistor * Slim design (modular construction) acc. to DIN 43880 * With pluggable protection modules * Function/failure indication according to VDE 0100-534 * With remote signaling contact (FM) * Vibration and shock tested acc. to EN 60068-2 Type wietap R M 2P 255 Technical Data SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Rated voltage (50/60 Hz) [V] Maximum continuous voltage AC [UC] Maximum continuous voltage DC [UC] Max. continuous operating voltage [MCOV] Voltage protection rating [VPR] Rated current AC Rated discharge current (8/20) [In] Total discharge current (8/20) [L+N-PE] [Itotal] Combined surge [UOC] Combined surge [L+N-PE] [UOC total] Protection level [L-N] [UP] Protection level [L/N-PE] [UP] Operating time [L-N] [t A] Operating time [L/N-PE] [t A] Maximum network overcurrent protection Short-circuit proof with network overcurrent protection with 25 A gL/gG TOV-voltage [L-N] [U T] TOV-voltage [L/N-PE] (I) [U T] TOV-voltage [L+N-PE] (II) [U T] Temperature range [TU] acc. to UL 1449 3rd edition acc. to EN 61643-11 Function/failure indication Wire range (min.) Wire range (max.) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Approvals Type wietap R M 2P 255 FM Technical Data SPD accord. to EN 61643-11 SPD accord. to IEC 61643-1 Rated voltage (50/60 Hz) [V] Maximum continuous voltage AC [UC] Maximum continuous voltage DC [UC] Max. continuous operating voltage [MCOV] Voltage protection rating [VPR] Rated current AC acc. UL 1449 3rd edition | EN 61643-11 Rated discharge current (8/20) [In] Total discharge current (8/20) [L+N-PE] [Itotal] Combined surge [UOC] Combined surge [L+N-PE] [UOC total] Protection level [L-N] [UP] Protection level [L/N-PE] [UP] Operating time [L-N] [t A] Operating time [L/N-PE] [t A] Maximum network overcurrent protection Short-circuit proof with network overcurrent protection with 25 A gL/gG TOV-voltage [L-N] [U T] TOV-voltage [L/N-PE] (I) [U T] TOV-voltage [L+N-PE] (II) [U T] Temperature range [TU] acc. to UL 1449 3rd edition acc. to EN 61643-11 Function/failure indication Wire range (min.) Wire range (max.) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts (FM) Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals Part No. 84.995.3200.0 Type 3 Category A / Class III 240 V 255 V 255 V 255 V 1200 V 20 A 3 kA 5 kA 6 kV 10 kV 1250 V 1500 V 25 ns 100 ns 25 A gL/gG or B 25 A 6 kArms 335 V / 5 sec. 400 V / 5 sec. 1200 V + UCS / 200 ms 0... +85 C -40... +85 C green / red 0.5 mm (AWG 20) solid/fine-stranded 4 mm (AWG 12) solid / 2.5 mm (AWG 14) fine-stranded 35 mm thermoplastic, UL 94 V-0 IP 20 1 mod., DIN 43880 AoKw Part No. 84.995.3205.0 Type 3 Category A / Class III 240 V 255 V 255 V 255 V 1200 V 20 A | 25 A 3 kA 5 kA 6 kV 10 kV 1250 V 1500 V 25 ns 100 ns 25 A gL/gG or B 25 A 6 kArms 335 V / 5 sec. 400 V / 5 sec. 1200 V + UCS / 200 ms 0... +85 C -40... +85 C green / red 0.5 mm (AWG 20) solid/fine-stranded 4 mm (AWG 12) solid / 2.5 mm (AWG 14) fine-stranded 35 mm thermoplastic, UL 94 V-0 IP 20 1 mod., DIN 43880 changeover contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm2 (AWG 16) solid/fine-stranded AoKw 31 32 wietap DC Solar Overvoltage protection for Photovoltaic systems Photovoltaic systems, abbreviated as PV systems, are a considerable investment that must be protected from failure and damage. As these systems are installed outdoors, they are exposed to the danger of overvoltage from lightning strikes. Overvoltage protection in the DC circuit with central inverters The generator circuit (the PV modules) produces a direct current. Connecting the PV modules and arrays in series allows voltages of 1000 V to be reached. This combination with the fact that the generator circuit can continue to supply energy after overvoltage requires sophisticated technology for the overvoltage arrester. DC overvoltage protection: The PV/DC overvoltage arresters are specially designed for use in PV systems. Both the housing technology and the connections are designed for the requirements of a PV systems high voltages and conductor crosssections. With a width of only 36 or 48 mm, the units are easily installed inside distribution panels, requiring the minimum of space. n High discharge capacity due to powerful zinc-oxide varistor DC n No fire hazard caused by permanent electric arc due to combined disconnect and short-circuit facility. Overload indicated in display window n Signaling contacts for remote monitoring in all remote signaling types AC overvoltage protection: On the AC side of the inverters overvoltage protection must also be installed. The arresters listed here are the most commonly used versions. Suitable units can be found inside the chapters wietap IEC and wietap UL/ CSA. 33 wietap DC Solar Surge protection for solar modules To be used in photovoltaic DC circuits wietap GS PV SCI 600 (FM) * DC solar arrester for 600 V string voltage Type wietap GS PV SCI 600 wietap GS PV SCI 600 FM Part No. 84.995.2550.0 84.995.2555.0 * For DC grounded solar systems * No fire hazard during overload due to combined disconnection and short-circuit device * Safe, arc-free replacement of protection modules due to integrated DC fuse * High discharge capacity * Function/failure indication * wietap GS PV SCI 600 FM with remote signaling contact (FM) Technical Data Connection between Conformity according SPD-accord. to EN 61643-11 SPD-accord. to IEC 61643-1 Maximum PV voltage [UPVmax] Protection level [UP] Protection level at 5 kA [UP] Nominal discharge current (8/20) [(DC+/DC-) a PE] [In] Max. discharge current (8/20) [(DC+/DC-) a PE] [Imax] Operating time [t A] Temperature range [TU] Short-circuit resistance (ISCWPV) Function/failure indication Wire range (min.) Wire range (max.) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts (FM) Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals 34 DC - Grnd prEN 50539-11 Type 2 Class II 600 V 2.5 kV 2 kV 12.5 kA 25 kA 25 ns -40 ... +80 C 1000 A green / red 1.5 mm (AWG 14) solid/fine-stranded 35 mm (AWG 2) stranded / 25 mm (AWG 4) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 2 TE, DIN 43880 (36 mm) Change-over contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm (AWG 14) solid/fine-stranded A Kw wietap DC Solar Surge protection for solar modules To be used in photovoltaic DC circuits wietap GM YPV SCI 600 (FM) * DC solar arrester for 600 V string voltage * No fire hazard during overload due to combined disconnection and short-circuit device * Safe, arc-free replacement of protection modules due to integrated DC fuse * High discharge capacity * Function/failure indication * wietap GM YPV SCI 600 FM with remote signaling contact (FM) Type wietap GM YPV SCI 600 wietap GM YPV SCI 600 FM Repl. module "+" or "-" against int. neutral point Repl. module int. neutral point against e Technical Data Connection between Conformity according SPD-accord. to EN 61643-11 SPD-accord. to IEC 61643-1 Maximum PV voltage [UPVmax] Protection level [UP] Protection level at 5 kA [UP] Total discharge current (8/20) [Itotal] Nominal discharge current (8/20) [(DC+/DC-) a PE] [In] Max. discharge current (8/20) [(DC+/DC-) a PE] [Imax] Operating time [t A] Temperature range [TU] Short-circuit resistance (ISCWPV) Function/failure indication Wire range (min.) Wire range (max.) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts (FM) Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals Part No. 84.995.2511.0 84.995.2516.0 84.995.2053.0 84.995.2010.0 DC+ - Grnd - DCprEN 50539-11 Type 2 Class II 600 V 2.5 kV 2 kV 40 kA 12.5 kA 25 kA 25 ns -40 ... +80 C 1000 A green / red 1.5 mm (AWG 14) solid/fine-stranded 35 mm (AWG 2) stranded / 25 mm (AWG 4) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 3 TE, DIN 43880 (54 mm) Change-over contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm (AWG 14) solid/fine-stranded A Kw Replacement module for wietap GM YPV SCI 600 (FM) wietap G MOD PV SCI 300 Type Part No. "+" or "-" against internal neutral point wietap G MOD PV SCI 300 84.995.2053.0 wietap G MOD 275 wietap G MOD 275 84.995.2010.0 Internal neutral point against PE 35 wietap DC Solar Surge protection for solar modules To be used in photovoltaic DC circuits wietap GM YPV SCI 1000 (FM) * DC solar arrester for 1000 V string voltage * No fire hazard during overload due to combined disconnection and short-circuit device * Safe, arc-free replacement of protection modules due to integrated DC fuse * High discharge capacity * Function/failure indication * wietap GM YPV SCI 1000 FM with remote signaling contact (FM) Type wietap GM YPV SCI 1000 wietap GM YPV SCI 1000 FM Repl. module "+" or "-" against int. neutral point Repl. module int. neutral point against e Technical Data Connection between Conformity according SPD-accord. to EN 61643-11 SPD-accord. to IEC 61643-1 Maximum PV voltage [UPVmax] Protection level [UP] Protection level at 5 kA [UP] Total discharge current (8/20) [Itotal] Nominal discharge current (8/20) [(DC+/DC-) a PE] [In] Max. discharge current (8/20) [(DC+/DC-) a PE] [Imax] Operating time [t A] Temperature range [TU] Short-circuit resistance (ISCWPV) Function/failure indication Wire range (min.) Wire range (max.) Mounted on DIN rail acc. to EN 60715 Housing material Degree of protection Dimensions Remote signaling contacts (FM) Switching capacity AC (FM) Switching capacity DC (FM) Wire range for remote signaling terminals Approvals Part No. 84.995.2510.0 84.995.2515.0 84.995.2051.0 84.995.2015.0 DC+ - Grnd - DCprEN 50539-11 Type 2 Class II 1000 V 4 kV 3.5 kV 40 kA 12.5 kA 25 kA 25 ns -40 ... +80 C 1000 A green / red 1.5 mm (AWG 14) solid/fine-stranded 35 mm (AWG 2) stranded / 25 mm (AWG 4) fine-stranded 35 mm Thermoplast, UL 94 V-0 IP 20 3 TE, DIN 43880 (54 mm) Change-over contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm (AWG 14) solid/fine-stranded A Kw Replacement module for wietap GM YPV SCI 1000 (FM) wietap G MOD PV SCI 500 Type Part No. "+" or "-" against internal neutral point wietap G MOD PV SCI 500 84.995.2051.0 wietap G MOD 440 wietap G MOD 440 84.995.2015.0 Internal neutral point against PE 36 wietap DC Solar Surge protection for solar modules To be used in photovoltaic DC circuits AC arrester on mains for Class 1 / 2 / 3 The used arrester type of the AC side is depending on the mains system. A suitable arrester with the relevant certifications can be found in the previous chapters. The suitable distribution for your project Housing Protection UV-resistant Material Cable connection Class II yes polycarbonate pluggable or gland Build in components * Termination points for solar connectors * Big termination points for inverter connection * PE connection * String fusing * Reverse current diodes * String monitoring * Main switch * Circuit breaker * Overvoltage protection and many more AC combiner box - erhohte losungen mit Schnittste Umweltbe dingunge n mit llen zu CAE -Systeme Bahn- u. Schi n ffszulassu ng gesis(R)SOL - Soft ware AR DC combiner box Wieland will support you during the planning phase. High product quality and documentation are a standard for us. More information and a planning tool can be found in the brochure gesis SOLAR, Part No. 0164.0, and at http://solar.gesis.wieland-electric.de DC gesis(R)SOLA R Elektrisch e technik fur InstallationsPhotovolta ik Katalog 37 38 wipos wipos Power supply units Pure Power. No-Frills. Power supplies perform a central function in the control cabinet. Their reliability affects the availability of the machine or the process to a great degree. That is why a robust and proven design is very important for a power supply unit. There are no unnecessary frills with the wipos family. Instead, these power supply units score with their fundamental features. wipos satisfies your requirements in the significant disciplines: 100 % power up to 60 C Can be connected in parallel (from 5 A) to increase power and redundancy Automatic or wide-input voltage range for worldwide use High operational reliability due to long hold-up times >30 ms PFC-technology for high functional reliability Compensation of voltage drops via adjustable output voltage Outdoor installation possible due to wide temperature range Easy to commission via LED diagnosis Active monitoring with signalling contact For mounting on DIN Rail TS 35 / TS 32 39 wipos wipos P1 Modules Power supply wipos P1 24-1.25 P1 24-2.5 Type wipos P1 24-1.25 wipos P1 24-2.5 Technical Data Input voltage PFC Hold up time Output voltage Output current Parallel operation In series connectable Temperature range Derating Signal contact Dimensions (mm) W x H x D Weight Type of connectors Connector size Efficiency Approvals Power supply wipos P1 24-3.8 P1 24-5 Type wipos P1 24-3.8 wipos P1 24-5 Technical Data Input voltage PFC Hold up time Output voltage Output current Parallel operation In series connectable Temperature range Derating Signal contact Dimensions (mm) W x H x D Weight Type of connectors Connector size Efficiency Approvals Power supply wipos P1 24-10 P1 24-20 Type wipos P1 24-10 wipos P1 24-20 Technical Data Input voltage PFC Hold up time Output voltage Output current Parallel operation In series connectable Temperature range Derating Signal contact Dimensions (mm) W x H x D Weight Type of connectors Connector size Efficiency Approvals 40 Part No. Part No. 81.000.6110.0 81.000.6120.0 85 - 264 V AC, 90 - 375 V DC not necessary not necessary > 30 ms at 230 V > 30 ms at 230 V 24 - 28 V 24 - 28 V 1.25 A 2.5 A no no yes yes -40 ... +70 C -40 ... +70 C > 60 C > 60 C yes yes 40.5 x 90 x 114 40.5 x 90 x 114 290 g 360 g Screw terminal Screw terminal 0.2 - 2.5 mm (AWG 24 - 14) 0.2 - 2.5 mm (AWG 24 - 14) 83 - 86 % 86 - 89 % 3 Y UL 1310 Class 2 3 Y UL 1310 Class 2 Haz. a Class I Div.2 Haz. a Class I Div.2 Part No. Part No. 81.000.6135.0 81.000.6130.0 115/230 V AC auto, 210 - 375 V DC yes yes > 30 ms at 230 V > 30 ms at 230 V 22.5 - 24,5 V 22.5 - 28.5 V 3.8 A 5A no yes (up to 3) yes yes -35 ... +70 C -35 ... +70 C > 60 C > 60 C yes yes 64 x 124.5 x 123.6 64 x 124.5 x 123.6 920 g 920 g Screw terminal Screw terminal 0.5 - 6 mm (AWG 22 - 10) 0.5 - 6 mm (AWG 22 - 10) 83 - 85 % 84 - 86 % 3 Y UL 1310 Class 2 3 Y Haz. a Class I Div.2 Haz. a Class I Div.2 Part No. Part No. 81.000.6140.0 81.000.6150.0 115/230 V AC auto, 210 - 375 V DC yes > 30 ms at 230 V 22.5 - 28.5 V 10 A yes (up to 3) yes -40 ... +70 C > 60 C yes 83.5 x 124.5 x 123.6 1300 g Screw terminal 0.5 - 6 mm (AWG 22 - 10) 87 - 89 % 3 Y Haz. a Class I Div.2 115/230 V AC auto 120 - 370 V DC yes > 30 ms at 230 V 22.5 - 28.5 V 20 A yes (up to 3) yes -40 ... +70 C > 55 C yes 175.5 x 124.5 x 123.6 1920 g Screw terminal 0.5 - 6 mm (AWG 22 - 10) 86 - 89 % 3 Y Haz. a Class I Div.2 wipos wipos P1 Modules Power supply wipos P1 12-5 Type wipos P1 12-5 Technical Data Input voltage PFC Hold up time Output voltage Output current Parallel operation In series connectable Temperature range Derating Signal contact Dimensions (mm) W x H x D Weight Type of connectors Connector size Efficiency Approvals Power supply wipos P1 12-10 Type wipos P1 12-10 Technical Data Input voltage PFC Hold up time Output voltage Output current Parallel operation In series connectable Temperature range Derating Signal contact Dimensions (mm) W x H x D Weight Type of connectors Connector size Efficiency Approvals Power supply wipos P1 48-5 Type wipos P1 48-5 Technical Data Input voltage PFC Hold up time Output voltage Output current Parallel operation In series connectable Temperature range Derating Signal contact Dimensions (mm) W x H x D Weight Type of connectors Connector size Efficiency Approvals Part No. 81.000.6132.0 85 - 264 V AC, 90 - 375 V DC not necessary > 30 ms at 230 V 12 - 14 V 5A no yes -40 ... +70 C >61 C no 40.5 x 90 x 114 340 g Screw terminal 0.2 - 2.5 mm (AWG 24 - 14) 86 % 3 Y Haz. a Class I Div.2 Part No. 81.000.6142.0 115/230 V AC auto, 210 - 375 V DC not necessary > 30 ms at 230 V 11,4 - 14,5 V 10 A yes (up to 3) yes -35 ... +70 C >61 C no 64 x 124.5 x 123.6 920 g Screw terminal 0.5 - 6 mm (AWG 22 - 10) 84 % 3 Y Haz. a Class I Div.2 Part No. 81.000.6134.0 115/230 V AC auto, 210 - 375 V DC not necessary >30 ms at 230 V 47 - 56 V 5A yes (up to 3) yes -40 ... +70 C >61 C no 83.5 x 124.5 x 123.6 1380 g Screw terminal 0.5 - 6 mm2 solid/fine str. (AWG 22 - 10) 90 % 3 Y Haz. a Class I Div.2 41 wipos wipos P3 Modules Power supply wipos P3 24-5 P3 24-10 Power supply wipos P3 24-20 Power supply wipos P3 24-40 Further Modules available on request. 42 Type wipos P3 24-5 wipos P3 24-10 Part No. Part No. 81.000.6160.0 81.000.6170.0 Technical Data Input voltage PFC Hold up time Output voltage Output current Parallel operation In series connectable Temperature range Derating Signal contact Dimensions (mm) W x H x D Weight Type of connectors Connector size Efficiency 340 - 575 V AC 480 - 820 V DC yes (0.55) 20 ms 22.5 - 28.5 V 5A yes (up to 2) yes -40 ... +70 C > 60 C yes 75 x 124 x 119 800 g Screw terminal to 6 mm (AWG 10) 88 - 90 % 340 - 575 V AC 480 - 820 V DC yes (0.6) 20 ms 22.5 - 28.5 V 10 A yes (up to 2) yes -40 ... +70 C > 60 C yes 89 x 124 x 119 1100 g Screw terminal to 6 mm (AWG 10) 88 - 90 % Approvals 3 Y Haz. a Class I Div.2 3 Y Haz. a Class I Div.2 Type Part No. wipos P3 24-20 81.000.6180.0 Technical Data Input voltage PFC Hold up time Output voltage Output current Parallel operation In series connectable Temperature range Derating Signal contact Dimensions (mm) W x H x D Weight Type of connectors Connector size Efficiency 340 - 575 V AC 480 - 820 V DC yes (0.7) 20 ms 22.5 - 28.5 V 20 A yes (up to2) yes -30 ... +70 C > 60 C yes 150 x 124 x 119 1750 g Screw terminal to 6 mm (AWG 10) 88 - 90 % Approvals 3 Y Haz. a Class I Div.2 Type Part No. wipos P3 24-40 81.000.6190.0 Technical Data Input voltage PFC Hold up time Output voltage Output current Parallel operation In series connectable Temperature range Derating Signal contact Dimensions (mm) W x H x D Weight Type of connectors Connector size Efficiency 340 - 575 V AC 480 - 820 V DC yes (0.7) 15 ms 22.5 - 28.5 V 40 A yes (up to 2) yes -40 ... +70 C >60 C yes 276 x 127 x 119 3200 g Screw terminal to 6 mm (AWG 10)/ output to 16 mm (AWG 6) 90 - 92 % Approvals 3 Y Haz. a Class I Div.2 wipos wipos Modules Redundancy module wipos R20 Fusing module wipos FM 4-10 Uninterrupted power supply wipos UPS 24-30 Type Part No. wipos R20 81.000.6200.0 Technical Data Input voltage Input current Output current Typical voltage drop Temperature range Signal contact Signal contact Display/Relay OK Display/Relay fail Dimensions (mm) W x H x D Weight Type of connectors Connector size Connector size for signal contacts 21 - 28 V DC 20 A (in total) 20 A 0.5 V -40 ... +70 C one each for channel A and B 1 A at 30 V DC Input voltage 20...30 V (+/-5 %) Input voltage <20 V or >30 V (+/-5 %) 54 x 90 x 114 210 g Screw terminal 0.2 - 2.5 mm (AWG 24 - 12) 0.2 - 1.5 mm (AWG 24 - 14) Approvals 3 Y Type Part No. wipos FM 4-10 81.000.6210.0 Technical Data Input voltage Output current via all 4 fuses Output voltage Number of fusing circuits Nominal current of fuse Fuses LED Alarm contact Temperature range Dimensions (mm) W x H x D Mounting type Weight Type of connectors Connector size input Connector size output 18 - 30 V 40 A max. 24 V (equivalent to input voltage) 4 max. 10 A (check power losses of fuse) 4 x G-fuse holder 5 x 20 mm one per fuse, LED lights whe fuse is broken yes 0 ... +60 C 48 x 96 x 68 DIN rail mounting 110 g Screw terminal 10 mm2 (AWG 8) up to 4 mm2 (AWG 12) solid,2.5 mm2 (AWG 14) fine-stranded Approvals 3 Y Type Part No. wipos UPS 24-30 81.000.6220.0 Technical Data Rated input voltage UIN Input current Rated output voltage UOUT Output current IOUT Output voltage (battery mode) Output current (battery mode) Temperature range Derating Signal contact mains or battery current Signal contact discharge battery Signal contact broken battery Battery type Battery size Dimensions (mm) W x H x D Weight Type of connectors Connector size 24 V DC max. 35 A 24 V DC max. 30 A 18.7 - 28.0 V max. 30 A -40 ... +70 C > 51 C yes yes yes Lead-acid or lead-gel 2 ... 12 Ah / 2 x 12 V 54 x 90 x 114 370 g Screw terminal 0.2-4 mm (AWG 24 - 12) Approvals 3 Y 43 wipos wipos PB1 Modules Power supply wipos PB1 5-1.5 PB1 5-3 Type Part No. wipos PB1 5-1.5 wipos PB1 5-3 81.000.6321.0 Technical Data Input voltage PFC Hold up time Output voltage Output current Temperature range Derating LED display Dimensions W x H x D Installation dimensions 90 - 264 V AC, 120 - 375 V DC not necessary > 80 ms at 230 V 5 - 5.5 V 3A -40 ... +70 C > 61 C yes 35 x 91 x 57 for junction boxes and flat control panels DIN rail mounting 130 g Screw terminal 0.2 - 2.5 mm (AWG 24 - 14) 82 % 3 Y UL 1310 Class 2 Type Part No. Part No. wipos PB1 12-0.83 wipos PB1 24-0.42 81.000.6302.0 Approvals Technical Data Input voltage PFC Hold up time Output voltage Output current Temperature range Derating LED display Dimensions W x H x D Installation dimensions Power supply wipos PB1 12-2 PB1 24-1 81.000.6300.0 Mounting type Weight Type of connectors Connector size Efficiency 90 - 264 V AC, 120 - 375 V DC not necessary > 30 ms at 230 V 12 V 0.83 A -40 ... +70 C > 61 C: 100 %, 70 C: 75 % yes 18 x 91 x 57 for junction boxes and flat control panels DIN rail mounting 65 g Screw terminal 0.2 - 2.5 mm (AWG 24 - 14) 78 % Approvals 3 Y Haz. a Class I Div.2 Type Part No. wipos PB1 12-2 wipos PB1 24-1 81.000.6322.0 Technical Data Input voltage PFC Hold up time Output voltage Output current Temperature range Derating LED display Dimensions W x H x D Installation dimensions 44 81.000.6331.0 90 - 264 V AC, 120 - 375 V DC not necessary > 30 ms at 230 V 5V 1.5 A -40 ... +70 C > 61 C yes 18 x 91 x 57 for junction boxes and flat control panels DIN rail mounting 65 g Screw terminal 0.2 - 2.5 mm (AWG 24 - 14) 74 % 3 Y UL 1310 Class 2 Haz. a Class I Div.2 Mounting type Weight Type of connectors Connector size Efficiency Power supply wipos PB1 12-0.83 PB1 24-0.42 Part No. 90 - 264 V AC, 120 - 375 V DC not necessary > 30 ms at 230 V 24 - 28 V 0.42 A -25 ... +70 C > 60 C yes 18 x 91 x 57 for junction boxes and flat control panels DIN rail mounting 65 g Screw terminal 0.2 - 2.5 mm (AWG 24 - 14) 80 % 3 Y UL 1310 Class 2 Haz. a Class I Div.2 Part No. 81.000.6310.0 Mounting type Weight Type of connectors Connector size Efficiency 90 - 264 V AC, 120 - 375 V DC not necessary > 80 ms at 230 V 12 - 14 V 2A -40 ... +70 C > 61 C: 100 %, 70 C: 75 % yes 35 x 91 x 57 for junction boxes and flat control panels DIN rail mounting 130 g Screw terminal 0.2 - 2.5 mm (AWG 24 - 14) 84 % 90 - 264 V AC, 120 - 375 V DC not necessary > 80 ms at 230 V 24 - 28 V 1A -25 ... +70 C > 60 C yes 35 x 91 x 57 for junction boxes and flat control panels DIN rail mounting 130 g Screw terminal 0.2 - 2.5 mm (AWG 24 - 14) 85 % Approvals 3 Y UL 1310 Class 2 3 Y UL 1310 Class 2 wipos wipos PB1 Modules Power supply wipos PB1 12-2.75 PB1 24-1.5 Type Part No. wipos PB1 12-2.75 wipos PB1 24-1.5 81.000.6332.0 Technical Data Input voltage PFC Hold up time Output voltage Output current Temperature range Derating LED display Dimensions W x H x D Installation dimensions Power supply wipos PB1 12-4.5 PB1 24-2.5 81.000.6320.0 Mounting type Weight Type of connectors Connector size Efficiency 90 - 264 V AC, 120 - 375 V DC not necessary > 60 ms at 230 V 12 - 14 V 4.5 A -40 ... +70 C > 56 C yes 71 x 91 x 57 for junction boxes and flat control panels DIN rail mounting 250 g Screw terminal 0.2 - 2.5 mm (AWG 24 - 14) 84 % 90 - 264 V AC, 120 - 375 V DC not necessary > 100 ms at 230 V 24 - 28 V 1.5 A -25 ... +70 C > 56 C yes 53 x 91 x 57 for junction boxes and flat control panels DIN rail mounting 190 g Screw terminal 0.2 - 2.5 mm (AWG 24 - 14) 84 % Approvals 3 Y UL 1310 Class 2 3 Y UL 1310 Class 2 Type Part No. Part No. wipos PB1 12-4.5 wipos PB1 24-2.5 81.000.6342.0 Technical Data Input voltage PFC Hold up time Output voltage Output current Temperature range Derating LED display Dimensions W x H x D Installation dimensions Mounting type Weight Type of connectors Connector size Efficiency Approvals Power supply wipos PB1 24-4.2 Part No. Type 81.000.6330.0 90 - 264 V AC, 120 - 375 V DC not necessary > 60 ms at 230 V 12 - 14 V 4,5 A -40 ... +70 C > 56 C ja 71 x 91 x 57 for junction boxes and flat control panels DIN rail mounting 250 g Screw terminal 0.2 - 2.5 mm (AWG 24 - 14) 84 % 3 Y UL 1310 Class 2 Haz. a Class I Div.2 90 - 264 V AC, 120 - 375 V DC not necessary > 60 ms at 230 V 24 - 28 V 2.5 A -25 ... +70 C > 60 C yes 71 x 91 x 57 for junction boxes and flat control panels DIN rail mounting and screw connection 250 g Screw terminal 0.2 - 2.5 mm (AWG 24 - 14) 86 % 3 Y UL 1310 Class 2 Haz. a Class I Div.2 Part No. wipos PB1 24-4.2 81.000.6340.0 Technical Data Input voltage PFC Hold up time Output voltage Output current Temperature range Derating LED display Dimensions W x H x D Installation dimensions Mounting type Weight Type of connectors Connector size Efficiency 90 - 264 V AC, 120 - 375 V DC not necessary > 60 ms at 230 V 24 - 28 V 4.2 A -40 ... +70 C > 60 C yes 90 x 91 x 57 for junction boxes and flat control panels DIN rail mounting and screw connection 380 g Screw terminal 0.2 - 2.5 mm (AWG 24 - 14) 89 % Approvals 3 Y Haz. a Class I Div.2 45 46 interface wienet Industrial Ethernet switches Safe and fast communication for your process. Ethernet connections have become part of many areas of life. This global standard is also making inroads into automation technology. Ethernet switches have become quite common for safe networking and coupling between machines, or inside the system. They manage the data flow in an effective and targetoriented manner. The devices are designed to be very robust and are optimally suited to harsh industrial environments. Benefits: n Redundant power supply n Full compatibility according to IEEE 802.3, including autocrossing, autonegotiation, autosensing, autopolarity n Complete diagnostics display via various LEDs n Compact design n DIN rail mounting or screw connection n Robust designs n High degree of protection (IP40) 47 wienet Ethernet Switches (Fast Ethernet) wienet UMS 6-L Type wienet UMS 6-L Technical Data Number of ports Port types Store and forward switching mode Autocrossing Autonegotiation Autosensing Autopolarity Full IEEE 802.3 compatibility Line, star and network topologies are possible Operating voltage Redundant power supply Diagnostic LEDs (power / link status / data / data rate) Operating temperature Dimensions (mm) W x H x D Housing Mounting Type of connectors Connector size Weight Degree of protection Approvals wienet UMS 6 Type wienet UMS 6 Technical Data Number of ports Port types Store and forward switching mode Autocrossing Autonegotiation Autosensing Autopolarity Full IEEE 802.3 compatibility Line, star and network topologies are possible Operating voltage Redundant power supply Diagnostic LEDs (power / link status / data / data rate) Operating temperature Dimensions (mm) W x H x D Housing Mounting Type of connectors Connector size Weight Degree of protection Approvals 48 Part No. 83.040.0000.1 6 RJ45 ports 6 x Ethernet and Fast Ethernet (10/100 Mbit/s) yes yes yes yes yes yes yes 9 ... 30 V DC 2 infeeds yes / yes / yes / yes 0 ... +60 C 45 x 90 x 80 Thermoset DIN rail and screw mounting Screw terminal, pluggable up to 1.5 mm (AWG 16) 160 g IP 40 AE FCC Part No. 83.040.0000.0 6 RJ45 ports 6 x Ethernet and Fast Ethernet (10/100 Mbit/s) yes yes yes yes yes yes yes 9 ... 30 V DC 2 infeeds yes / yes / yes / yes 0 ... +60 C 45.3 x 90 x 90.5 Aluminum extrusion DIN rail and screw mounting Screw terminal, pluggable up to 1.5 mm (AWG 16) 250 g IP 40 AE FCC wienet Ethernet Switches (Fast Ethernet) wienet UMS 8 Type wienet UMS 8 Technical Data Number of ports Port types Store and forward switching mode Autocrossing Autonegotiation Autosensing Autopolarity Full IEEE 802.3 compatibility Line, star and network topologies are possible Operating voltage Redundant power supply Diagnostic LEDs (power / link status / data / data rate) Operating temperature Dimensions (mm) W x H x D Housing Mounting Type of connectors Connector size Weight Degree of protection Approvals Part No. 83.040.0001.0 8 RJ45-Ports 8 x Ethernet and Fast-Ethernet (10/100 Mbit/s) yes yes yes yes yes yes yes 9 ... 30 V DC 2 infeeds yes / yes / yes / yes -10 ... +70 C 45.3 x 90 x 90.5 Aluminum extrusion DIN rail and screw mounting Screw terminal, pluggable up to 1.5 mm (AWG 16) 270 g IP 40 AE FCC 49 wienet Ethernet Switches (Giga Ethernet) wienet UMS 8-G Type wienet UMS 8-G Technical Data Number of ports Port types Store and forward switching mode Autocrossing Autonegotiation Autosensing Autopolarity Full IEEE 802.3 compatibility Line, star and network topologies are possible Operating voltage Redundant power supply Diagnostic LEDs (power / link status / data / data rate) Operating temperature Dimensions (mm) W x H x D Housing Mounting Type of connectors Connector size Weight Degree of protection Approvals wienet UMS 8-2G Type wienet UMS 8-2G Technical Data Number of ports Port types Store and forward switching mode Autocrossing Autonegotiation Autosensing Autopolarity Full IEEE 802.3 compatibility Line, star and network topologies are possible Operating voltage Redundant power supply Diagnostic LEDs (power / link status / data / data rate) Operating temperature Dimensions (mm) W x H x D Housing Mounting Type of connectors Connector size Weight Degree of protection Approvals 50 Part No. 83.040.0106.0 8 x RJ45 6 x Giga-Ethernet (10/100/1000 Mbit/s) yes yes yes yes yes yes yes 9 ... 48 V DC 2 infeeds yes / yes / yes / yes -10 ... +70 C 45.3 x 90 x 90.5 Metal DIN rail and screw mounting Screw terminal, pluggable 0.2 - 1.5 mm (AWG 24 - 16) 255 g IP 50 AE FCC Part No. 83.040.0103.0 10 RJ45-Ports 8 x Ethernet and Fast-Ethernet (10/100 Mbit/s) 2 x Giga-Ethernet (10/100/1000 Mbit/s) yes yes yes yes yes yes yes 12 ... 48 V DC 2 infeeds yes / yes / yes / yes -40 ... +70 C 54 x 146 x 130.5 Aluminum extrusion DIN rail and screw mounting Screw terminal, pluggable up to 1.5 mm (AWG 16) 1000 g IP 40 AE FCC wienet Ethernet Switches (with optical ports) wienet UMS 4-1FM Type wienet UMS 4-1FM Technical Data Number of ports Port types Store and forward switching mode Autocrossing Autonegotiation Autosensing Autopolarity Full IEEE 802.3 compatibility Line, star and network topologies are possible Operating voltage Redundant power supply Diagnostic LEDs (power / link status / data / data rate) Operating temperature Dimensions W x H x D Housing Mounting Type of connectors Connector size Weight Degree of protection Approvals wienet UMS 4-1FS Type wienet UMS 4-1FS Technical Data Number of ports Port types Store and forward switching mode Autocrossing Autonegotiation Autosensing Autopolarity Full IEEE 802.3 compatibility Line, star and network topologies are possible Operating voltage Redundant power supply Diagnostic LEDs (power / link status / data / data rate) Operating temperature Dimensions W x H x D Housing Mounting Type of connectors Connector size Weight Degree of protection Approvals Part No. 83.040.0002.0 4 x RJ45, 1 x ST (optical multi mode) 10/100BaseT(X), 100BaseFX yes yes yes yes yes yes yes 9 ... 30 V DC 2 infeeds yes / yes / yes / yes -10 ... +70 C 45.3 x 90 x 90.5 Metal DIN rail and screw mounting Screw terminal, pluggable 0.2 - 1.5 mm (AWG 24 - 16) 260 g IP 50 AE FCC Part No. 83.040.0003.0 4 x RJ45, 1 x SC (optical single mode) 10/100BaseT(X), 100BaseFX yes yes yes yes yes yes yes 9 ... 30 V DC 2 infeeds yes / yes / yes / yes -10 ... +70 C 45.3 x 90 x 90.5 Metal DIN rail and screw mounting Screw terminal, pluggable 0.2 - 1.5 mm (AWG 24 - 16) 260 g IP 50 AE FCC 51 wienet Applications n Energy systems * Wind turbines * Solar farms * Biogas cogeneration systems * Heat pumps, ... n Water and waste water Management n System monitoring in machine building * Washing machines * Packaging machines * Compressors, ... n External surveillance camera n Vending Telemetry online sales or ticket machines n Smart metering n Mobile Fleet Management 52 wienet wienet VPN Industrial Router - unlimited M2M communication Functionality which convinces Whether it is about the control of machines, monitoring of production lines or the coordination of all production areas a permanent communication between devices is needed to complete such a complex task. Access to stored data using wireless networks is not always possible or safe. Now Wieland offers with its modern router technology the possibility of completing such complex tasks. For example control commands, level indicators or video signals can now be transmitted. At download speeds of up to 100 Mbit/s and upload speeds of up to 50 Mbits/s (depending on the network operator) the wienet VPN industrial router is sure to cover the available connectivity options of GPRS up to LTE. With automatic login wienet VPN industrial router will always access the fastest available connection. Each router has its own IP address and can be configured through the integrated web interface. It supports services such as DHCP, NAT and DynDNS. The routers communicate directly or via the control panel to open a secure VPN connection. The establishment of an IPSec encrypted tunnel is alternatively possible. wienet VPN routers are ideal components for industrial use in conjunction with VPN-service portals, such as Wie-Service24. With the arrangement of the ports on the frontpanel and a standard USB port, the wienet VPN industrial router are extremely user friendly. A clear statistic of mobile connections is used for better control. Optionally, the devices are available with a second SIM card slot, additional I/O, RS-232, RS-422/RS-485, M-Bus, second Ethernet interface, Wi-Fi module or integrated 3 port switch. Open VPN HSDPA HSDPA Highspeed Router VPN SMS RJ45 GPRS Open HSDPA 21,1 Mbit/s DynDNS EDGE UMTS Highspeed Router Ipsec SMS GPRS HSPA+ Open VPN HSUPA E-Mail HSPA+ HSDPA DynDNS RJ45 GSM EDGE UMTS Ipsec 21,1 Mbit/s HSPA+ Open VPN HSUPA E-Mail HSPA+ Highspee Ipsec SMS DHCP GSM Highspeed Router Highspeed Router GSM HSDPA EDGE UMT HSPA+ Open VPN HSU Highspeed Router 53 wienet Industrial Mobile Router - GSM / GPRS / EDGE EDGE mobile router Basic" wienet EDGE ER75i v2 * 1x SIM-card-slot * 1x RJ45-Port extension * Inclusive antenna * Inclusive RJ45-Patch cable * Inclusive DIN Rail clip * Plastic or metal housing Type EDGE mobile router basic version wienet EDGE ER75iv2 wienet EDGE ER75iv2 RS232 wienet EDGE ER75iv2 RS485/422 wienet EDGE ER75iv2 MBUS wienet EDGE ER75iv2 CNT wienet EDGE ER75iv2 ETH Technical Data Housing Dimensions (mm) W x H x D Weight Transmission Frequency bands SIM-card-slots RJ45-extension-ports Interfaces Max. Download/Upload VPN-Client for encrypted connection to the control center Mounting Operating voltage Operating temperature Antenna Approvals Norms Port 1 RS-232 RS-485/422 M-Bus 4DI, 2DO, 2AI Ethernet Port 2 - Part No. Part No. Aluminium Plastic 83.041.0000.1 83.041.0001.1 83.041.0002.1 83.041.0003.1 83.041.0004.1 83.041.0005.1 83.041.0000.0 83.041.0004.0 83.041.0005.0 Aluminium Plastic 42 x 113 x 81 42 x 113 x 76 280 g 220 g GSM/GPRS/EDGE (Class 10) 850/900/1800/1900 MHz 1 1 Ethernet 10/100 Mbit/s; USB 2.0 Type A (Host); 1x Digital In / 1x Digital Out 236 Kbit/s / 118,4 Kbit/s IPSec Client/Server; OpenVPN Client/Server; L2TP; PPTP DIN-rail or table 10 - 30 V DC -30 ... +60C External GSM-antenna (SMA - 50 Ohm) 3 EN 301 511, v 9.0.2; EN 301 908-1&2, v 3.2.1; ETSI EN 301 489-1 V1.8.1; EN 60950-1:06 ed. 2 + A11:09 Functions Support of NAT/PAT and X.509 Firewall (SPI) VPN: OpenVPN, IPsec, L2TP, GRE Easy web interface, DHCP, DynDNS, VRRP; Dial-in Router-control by SMS Comprehensive mobile statistic options Data volume-/roaming-control by SMS Status information by SNMP and SMS Status by LED FTP Linux based Operating System: ability to integrate their own applications EDGE mobil router Full" wienet EDGE ER75i v2f SL * 2x SIM-card-slot * 2x RJ45-Port extension * Inclusive antenna * Inclusive RJ45-Patch cable * Inclusive DIN Rail clip * Plastic or metal housing Type EDGE mobil router full version wienet EDGE ER75iv2f SL wienet EDGE ER75iv2f SL RS232 wienet EDGE ER75iv2f SL RS485/422 wienet EDGE ER75iv2f SL MBUS wienet EDGE ER75iv2f SL IO wienet EDGE ER75iv2f SL ETH wienet EDGE ER75iv2f SL WIFI wienet EDGE ER75iv2f SL RS232 RS232 wienet EDGE ER75iv2f SL RS485 RS232 wienet EDGE ER75iv2f SL MBUS RS232 wienet EDGE ER75iv2f SL CNT RS232 wienet EDGE ER75iv2f SL ETH RS232 wienet EDGE ER75iv2f SL RS485 RS485 wienet EDGE ER75iv2f SL MBUS RS485 wienet EDGE ER75iv2f SL CNT RS485 wienet EDGE ER75iv2f SL ETH RS485 wienet EDGE ER75iv2f SL RS232 WIFI wienet EDGE ER75iv2f SL RS485 WIFI wienet EDGE ER75iv2f SL MBUS WIFI wienet EDGE ER75iv2f SL CNT WIFI wienet EDGE ER75iv2f SL ETH WIFI wienet EDGE ER75iv2f SL 3P Port 1 RS-232 RS-485/422 M-Bus IO ETH RS-232 RS-485/422 M-Bus IO ETH RS-485/422 M-Bus IO ETH RS-232 RS-485/422 M-Bus IO ETH 3-port Switch Technical Data SIM-card-slots RJ45-extension-ports Further technical data see basic version 2 2 Functions see basic version 54 Port 2 WI-FI/WLAN RS-232 RS-232 RS-232 RS-232 RS-232 RS-485/422 RS-485/422 RS-485/422 RS-485/422 WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN 3-port Switch Part No. Part No. Aluminium Plastic 83.041.0100.1 83.041.0101.1 83.041.0102.1 83.041.0103.1 83.041.0104.1 83.041.0105.1 83.041.0106.1 83.041.0111.1 83.041.0112.1 83.041.0113.1 83.041.0114.1 83.041.0115.1 83.041.0122.1 83.041.0123.1 83.041.0124.1 83.041.0125.1 83.041.0161.1 83.041.0162.1 83.041.0163.1 83.041.0164.1 83.041.0165.1 83.041.0199.1 - wienet Industrial Mobile Router - UMTS UMTS mobil router Basic" wienet UMTS UR5 v2 * 1x SIM-card-slot * 1x RJ45-Port extension * Inclusive antenna * Inclusive RJ45-Patch cable * Inclusive DIN Rail clip * Plastic or metal housing Type UMTS mobile router basic version wienet UMTS UR5v2 wienet UMTS UR5v2 RS232 wienet UMTS UR5v2 RS485/422 wienet UMTS UR5v2 MBUS wienet UMTS UR5v2 CNT wienet UMTS UR5v2 ETH Technical Data Housing Dimensions (mm) W x H x D Weight Transmission Frequency bands - Dual-Band SIM-card-slots RJ45-extension-ports Interfaces Max. Download/Upload VPN-Client for encrypted connection to the control center Mounting Operating voltage Operating temperature Antenna Approvals Norms Port 1 RS-232 RS-485/422 M-Bus 4DI, 2DO, 2AI Ethernet Port 2 - Part No. Part No. Aluminium Plastic 83.041.0020.1 83.041.0021.1 83.041.0022.1 83.041.0023.1 83.041.0024.1 83.041.0025.1 83.041.0020.0 83.041.0025.0 Aluminium Plastic 42 x 113 x 81 42 x 113 x 76 280 g 220 g GSM/GPRS/EDGE/UMTS/HSDPA UMTS: 900/2100 MHz; GSM: 900/1800 MHz 1 1 Ethernet 10/100 Mbit/s; USB 2.0 Type A (Host); 1x Digital In / 1x Digital Out 3,6 Mbit/s / 384Kbit/s IPSec Client/Server; OpenVPN Client/Server; L2TP; PPTP DIN-rail or table 10 - 30 V DC -30 ... +60C External GSM-antenna (SMA - 50 Ohm) 3 EN 301 511, v 9.0.2; EN 301 908-1&2, v 3.2.1; ETSI EN 301 489-1 V1.8.1; EN 60950-1:06 ed. 2 + A11:09 Functions Support of NAT/PAT and X.509 Firewall (SPI) VPN: OpenVPN, IPsec, L2TP, GRE Easy web interface, DHCP, DynDNS, VRRP; Dial-in Router-control by SMS Comprehensive mobile statistic options Data volume-/roaming-control by SMS Status information by SNMP and SMS Status by LED FTP Linux based Operating System: ability to integrate their own applications UMTS mobile router Full" wienet UMTS UR5 v2f SL * 2x SIM-card-slot * 2x RJ45-Port extension * Inclusive antenna * Inclusive RJ45-Patch cable * Inclusive DIN Rail clip * Plastic or metal housing Type UMTS mobile router full version wienet UMTS UR5v2f SL wienet UMTS UR5v2f SL RS232 wienet UMTS UR5v2f SL RS485/422 wienet UMTS UR5v2f SL MBUS wienet UMTS UR5v2f SL IO wienet UMTS UR5v2f SL ETH wienet UMTS UR5v2f SL WIFI wienet UMTS UR5v2f SL RS232 RS232 wienet UMTS UR5v2f SL RS485 RS232 wienet UMTS UR5v2f SL MBUS RS232 wienet UMTS UR5v2f SL CNT RS232 wienet UMTS UR5v2f SL ETH RS232 wienet UMTS UR5v2f SL RS485 RS485 wienet UMTS UR5v2f SL MBUS RS485 wienet UMTS UR5v2f SL CNT RS485 wienet UMTS UR5v2f SL ETH RS485 wienet UMTS UR5v2f SL RS232 WIFI wienet UMTS UR5v2f SL RS485 WIFI wienet UMTS UR5v2f SL MBUS WIFI wienet UMTS UR5v2f SL CNT WIFI wienet UMTS UR5v2f SL ETH WIFI wienet UMTS UR5v2f SL 3P Port 1 RS-232 RS-485/422 M-Bus IO ETH RS-232 RS-485/422 M-Bus IO ETH RS-485/422 M-Bus IO ETH RS-232 RS-485/422 M-Bus IO ETH 3-port Switch Technical Data SIM-card-slots RJ45-extension-ports Further technical data see basic version 2 2 Port 2 WI-FI/WLAN RS-232 RS-232 RS-232 RS-232 RS-232 RS-485/422 RS-485/422 RS-485/422 RS-485/422 WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN 3-port Switch Part No. Part No. Aluminium Plastic 83.041.0200.1 83.041.0201.1 83.041.0202.1 83.041.0203.1 83.041.0204.1 83.041.0205.1 83.041.0206.1 83.041.0211.1 83.041.0212.1 83.041.0213.1 83.041.0214.1 83.041.0215.1 83.041.0222.1 83.041.0223.1 83.041.0224.1 83.041.0225.1 83.041.0261.1 83.041.0262.1 83.041.0263.1 83.041.0264.1 83.041.0265.1 83.041.0299.1 - Functions see basic version 55 interface Industrial Mobile Router - HSPA+ HSPA+ mobile router Basic" wienet HSPA+ UR5i v2 * 1x SIM-card-slot * 1x RJ45-Port extension * Inclusive antenna * Inclusive RJ45-Patch cable * Inclusive DIN Rail clip * Plastic or metal housing Type HSPA+ mobile router basic version wienet HSPA+ UR5iv2 wienet HSPA+ UR5iv2 RS232 wienet HSPA+ UR5iv2 RS485/422 wienet HSPA+ UR5iv2 MBUS wienet HSPA+ UR5iv2 CNT wienet HSPA+ UR5iv2 ETH Technical Data Housing Dimensions (mm) W x H x D Weight Transmission Frequency bands SIM-card-slots RJ45-extension-ports Interfaces Max. Download/Upload VPN-Client for encrypted connection to the control center Mounting Operating voltage Operating temperature Antenna Approvals Norms Port 1 RS-232 RS-485/422 M-Bus 4DI, 2DO, 2AI Ethernet Port 2 - Part No. Part No. Aluminium Plastic 83.041.0040.1 83.041.0041.1 83.041.0042.1 83.041.0043.1 83.041.0044.1 83.041.0045.1 83.041.0040.0 83.041.0045.0 Aluminium Plastic 42 x 113 x 81 42 x 113 x 76 280 g 220 g GSM/GPRS/EDGE/UMTS/HSDPA/HSPA+ Quad-Band UMTS (WCDMA): 850/900/1900/2100 MHz Quad-Band GSM/GPRS/EDGE: 850/900/1800/1900 MHz 1 1 Ethernet 10/100 Mbit/s; USB 2.0 Type A (Host); 1x Digital In / 1x Digital Out 21,1 Mbit/s / 5,7Mbit/s IPSec Client/Server; OpenVPN Client/Server; L2TP; PPTP DIN-rail or table 10 - 30 V DC -30 ... +60C External GSM-antenna (SMA - 50 Ohm) 3 EN 301 511, v 9.0.2; EN 301 908-1&2, v 3.2.1; ETSI EN 301 489-1 V1.8.1; EN 60950-1:06 ed. 2 + A11:09 Functions Support of NAT/PAT and X.509 Firewall (SPI) VPN: OpenVPN, IPsec, L2TP, GRE Easy web interface, DHCP, DynDNS, VRRP; Dial-in Router-control by SMS Comprehensive mobile statistic options Data volume-/roaming-control by SMS Status information by SNMP and SMS Status by LED FTP Linux based Operating System: ability to integrate their own applications HSPA+ mobilfunkrouter Full" wienet HSPA+ UR5i v2f SL * 2x SIM-card-slot * 2x RJ45-Port extension * Inclusive antenna * Inclusive RJ45-Patch cable * Inclusive DIN Rail clip * Plastic or metal housing Type HSPA+ mobile router full version wienet HSPA+ UR5iv2f SL wienet HSPA+ UR5iv2f SL RS232 wienet HSPA+ UR5iv2f SL RS485/422 wienet HSPA+ UR5iv2f SL MBUS wienet HSPA+ UR5iv2f SL IO wienet HSPA+ UR5iv2f SL ETH wienet HSPA+ UR5iv2f SL WIFI wienet HSPA+ UR5iv2f SL RS232 RS232 wienet HSPA+ UR5iv2f SL RS485 RS232 wienet HSPA+ UR5iv2f SL MBUS RS232 wienet HSPA+ UR5iv2f SL CNT RS232 wienet HSPA+ UR5iv2f SL ETH RS232 wienet HSPA+ UR5iv2f SL RS485 RS485 wienet HSPA+ UR5iv2f SL MBUS RS485 wienet HSPA+ UR5iv2f SL CNT RS485 wienet HSPA+ UR5iv2f SL ETH RS485 wienet HSPA+ UR5iv2f SL RS232 WIFI wienet HSPA+ UR5iv2f SL RS485 WIFI wienet HSPA+ UR5iv2f SL MBUS WIFI wienet HSPA+ UR5iv2f SL CNT WIFI wienet HSPA+ UR5iv2f SL ETH WIFI wienet HSPA+ UR5iv2f SL 3P Port 1 RS-232 RS-485/422 M-Bus IO ETH RS-232 RS-485/422 M-Bus IO ETH RS-485/422 M-Bus IO ETH RS-232 RS-485/422 M-Bus IO ETH 3-port Switch Technical Data SIM-card-slots RJ45-extension-ports Further technical data see basic version 2 2 Functions see basic version 56 Port 2 WI-FI/WLAN RS-232 RS-232 RS-232 RS-232 RS-232 RS-485/422 RS-485/422 RS-485/422 RS-485/422 WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN 3-port Switch Part No. Part No. Aluminium Plastic 83.041.0400.1 83.041.0401.1 83.041.0402.1 83.041.0403.1 83.041.0404.1 83.041.0405.1 83.041.0406.1 83.041.0411.1 83.041.0412.1 83.041.0413.1 83.041.0414.1 83.041.0415.1 83.041.0422.1 83.041.0423.1 83.041.0424.1 83.041.0425.1 83.041.0461.1 83.041.0462.1 83.041.0463.1 83.041.0464.1 83.041.0465.1 83.041.0499.1 - interface Industrial Mobile Router - LTE 4G LTE mobile router 4G Basic" wienet LTE LR77 v2 SL * 1x SIM-card-slot * 1x RJ45-Port extension * Inclusive antenna * Inclusive RJ45-Patch cable * Inclusive DIN Rail clip * Plastic or metal housing Type LTE-Mobilfunkrouter 4G basic version wienet LTE LR77v2 wienet LTE LR77v2 RS232 wienet LTE LR77v2 RS485/422 wienet LTE LR77v2 MBUS wienet LTE LR77v2 CNT wienet LTE LR77v2 ETH Technical Data Housing Dimensions (mm) W x H x D Weight Transmission Frequency bands SIM-card-slots RJ45-extension-ports Interfaces Max. Download/Upload VPN-Client for encrypted connection to the control center Mounting Operating voltage Operating temperature Antenna Approvals Norms Port 1 RS-232 RS-485/422 M-Bus 4DI, 2DO, 2AI Ethernet Port 2 - Part No. Part No. Aluminium Plastic 83.041.0050.1 83.041.0051.1 83.041.0052.1 83.041.0053.1 83.041.0054.1 83.041.0055.1 83.041.0050.0 83.041.0055.0 Aluminium Plastic 42 x 113 x 81 42 x 113 x 76 280 g 220 g GSM/GPRS/EDGE/UMTS/HSDPA/HSPA+/LTE LTE: 800/900/1800/2100/2600 MHz; UMTS: 900/ 2100 MHz; GSM/GPRS/EDGE: 900/1800/1900 MHz 1 1 Ethernet 10/100 Mbit/s; USB 2.0 Type A (Host); 1x Digital In / 1x Digital Out 100 Mbit/s / 50 Mbit/s IPSec Client/Server; OpenVPN Client/Server; L2TP; PPTP DIN-rail or table 10 - 30 V DC -30 ... +60C External GSM-antenna (SMA - 50 Ohm) 3 EN 301 511, v 9.0.2; EN 301 908-1&2, v 3.2.1; ETSI EN 301 489-1 V1.8.1; EN 60950-1:06 ed. 2 + A11:09 Functions Support of NAT/PAT and X.509 Firewall (SPI) VPN: OpenVPN, IPsec, L2TP, GRE Easy web interface, DHCP, DynDNS, VRRP; Dial-in Router-control by SMS Comprehensive mobile statistic options Data volume-/roaming-control by SMS Status information by SNMP and SMS Status by LED FTP Linux based Operating System: ability to integrate their own applications LTE mobile router 4G Full" wienet LTE LR77 v2f SL * 2x SIM-card-slot * 2x RJ45-Port extension * Inclusive antenna * Inclusive RJ45-Patch cable * Inclusive DIN Rail clip * Plastic or metal housing Type LTE mobile router 4G full version wienet LTE LR77v2f SL wienet LTE LR77v2f SL RS232 wienet LTE LR77v2f SL RS485/422 wienet LTE LR77v2f SL MBUS wienet LTE LR77v2f SL IO wienet LTE LR77v2f SL ETH wienet LTE LR77v2f SL WIFI wienet LTE LR77v2f SL RS232 RS232 wienet LTE LR77v2f SL RS485 RS232 wienet LTE LR77v2f SL MBUS RS232 wienet LTE LR77v2f SL CNT RS232 wienet LTE LR77v2f SL ETH RS232 wienet LTE LR77v2f SL RS485 RS485 wienet LTE LR77v2f SL MBUS RS485 wienet LTE LR77v2f SL CNT RS485 wienet LTE LR77v2f SL ETH RS485 wienet LTE LR77v2f SL RS232 WIFI wienet LTE LR77v2f SL RS485 WIFI wienet LTE LR77v2f SL MBUS WIFI wienet LTE LR77v2f SL CNT WIFI wienet LTE LR77v2f SL ETH WIFI wienet LTE LR77v2f SL 3P Port 1 RS-232 RS-485/422 M-Bus IO ETH RS-232 RS-485/422 M-Bus IO ETH RS-485/422 M-Bus IO ETH RS-232 RS-485/422 M-Bus IO ETH 3-port Switch Technical Data SIM-card-slots RJ45-extension-ports Further technical data see basic version 2 2 Port 2 WI-FI/WLAN RS-232 RS-232 RS-232 RS-232 RS-232 RS-485/422 RS-485/422 RS-485/422 RS-485/422 WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN 3-port Switch Part No. Part No. Aluminium Plastic 83.041.0500.1 83.041.0501.1 83.041.0502.1 83.041.0503.1 83.041.0504.1 83.041.0505.1 83.041.0506.1 83.041.0511.1 83.041.0512.1 83.041.0513.1 83.041.0514.1 83.041.0515.1 83.041.0522.1 83.041.0523.1 83.041.0524.1 83.041.0525.1 83.041.0561.1 83.041.0562.1 83.041.0563.1 83.041.0564.1 83.041.0565.1 83.041.0599.1 - Functions see basic version 57 interface Industrial Router - LAN-to-LAN LAN-to-LAN router wienet LAN XR5i v2 * inklusive 2xRJ45-Patch cable * Inclusive DIN Rail clip * Plastic or metal housing Type LAN-to-LAN router wienet LAN XR5iv2 ETH wienet LAN XR5iv2f SL ETH RS232 wienet LAN XR5iv2f SL ETH RS485 wienet LAN XR5iv2f SL RS232 WIFI wienet LAN XR5iv2f SL RS485 WIFI wienet LAN XR5iv2f SL MBUS WIFI wienet LAN XR5iv2f SL IO WIFI wienet LAN XR5iv2f SL ETH WIFI Technical Data Housing Dimensions (mm) W x H x D Weight Transmission RJ45-extension-ports Interfaces Max. Download/Upload VPN-Client for encrypted connection to the control center Mounting Operating voltage Operating temperature Approvals Norms Port 1 Ethernet Ethernet Ethernet RS-232 RS-485 M-Bus 4DI, 2DO, 2AI Ethernet Port 2 RS-232 RS-485 WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN WI-FI/WLAN Part No. Part No. Aluminium Plastic 83.041.0065.1 83.041.0071.1 83.041.0072.1 83.041.0081.1 83.041.0082.1 83.041.0083.1 83.041.0084.1 83.041.0085.1 83.041.0065.0 - Aluminium Plastic 42 x 113 x 81 42 x 113 x 76 280 g 220 g LAN-to-LAN, WI-FI/WLAN 1 (basic version), 2 (full version) Ethernet 10/100 Mbit/s; USB 2.0 Typ A (Host); 1x Digital In / 1x Digital Out Fast Ethernet IPSec Client/Server; L2TP; PPTP DIN-rail or table 10 - 30 V DC -30 ... +60C 3 ETSI EN 301 489-1 V1.8.1; EN 60950-1:06 ed. 2 + A11:09 Functions Support of NAT/PAT and X.509 Firewall (SPI) VPN: OpenVPN, IPsec, L2TP, GRE Easy web interface, DHCP, DynDNS, VRRP; Dial-in PPPoE - DSL-Modem Support Status by LED SNMP - Integration to the network management FTP Linux based Operating System: ability to integrate their own applications Omnidirectional rod antenna wienet GXS606 Type Typ Part No. Bestell-Nr. wienet GXS606 83.041.0210.0 Technical Data Frequency bandwidth Connector Gain Length of cable Dimensions GSM, GPRS, EDGE, UMTS FME/F 2.2 dBi 5m Length of rod approx. 300 mm Top flat antenna wienet GXR623 Type Part No. wienet GXR623 83.041.0200.0 Technical Data Frequency bandwidth Connector Gain Length of cable Dimensions GSM, GPRS, EDGE, UMTS FME/F 2.2 dBi 2.5 m approx. 75 x 80 x 13 mm 58 interface VPN-Server Wie-Service24" Additional VPN channels to VPNserver Wie-Service24 * Rent of additional VPN-tunnels to VPN-Server of Wieland Electric * High availability of VPN connections * Immediately usable * Client access on the server Customer installation of the VPN server Wie-Service24 * Customer installation of the VPN server * Administration on customer side * High availability of VPN connections * Customized layout possible Type Part No. wienet WIE-SERVICE24-EINZEL-R wienet WIE-SERVICE24-EINZEL-PC VPN-Router-Client VPN-PC-Client ZD.000.0011.0 ZD.000.0011.1 Properties Security by VPN Automatic generation of router configurations Only outgoing connections to the VPN server Wie-Service24 No changes in the local network needed Connection complete networks without additional route settings Contract data Calculation Termination Administration Server hardware 12 months in advance any time at the end of a month Wieland Electric Internet high-performance computing center Type Installation Part No. Virtual machine "Oracle Virtual Box" On energy-saving PC hardware On High Performance 19 "PC In customer data center In internet data center ("in the cloud") ZD.000.0012.0 ZD.000.0013.0 ZD.000.0014.0 ZD.000.0015.0 ZD.000.0016.0 wienet wienet wienet wienet wienet WIESERVICE24-VM WIESERVICE24-IPC SAVE WIESERVICE24-IPC HIGH WIESERVICE24-DC CUSTOM WIESERVICE24-DC INTERN. Properties Security by VPN Automatic generation of router configurations Only outgoing connections to the VPN server Wie-Service24 No changes in the local network needed Connection complete networks without additional route settings Contract data Calculation Number of VPN connections Administration Server hardware Fixed rate > 1000 customer selectable 59 wienet More security, more service, simply more Wie-Service24 Open VPN HSDPA HSDPA Highspeed Router VPN SMS RJ45 GPRS Open pen HSDPA 21,1 Mbit/s DynDNS EDGE DGE UMTS Highspeed High hspeed ed Router I SMS S HSPA+ Open VP PN HSUPA E-M Mail HSPA+ HSDPA DynDNS RJ45 GSM EDGE HSPA+ H SPA Open VPN HSUPA GSM 21,1 Muter bit/s bi Highsp Hig HSPA+ Highspeed Router er A perfect team The Wie-Service24 portal is optimized for the Wieland mobile and LAN-toLAN router. It automatically generates the configuration of the router and provides it for download. By this automatic setup possible failures will be minimized. Wie-Service24 generates and categorizes certificates for Wieland router. It regulates within a bigger group who is able to communicate with who. The combination of WieService24 and the Wieland router enable a fast commissioning and a highly secure VPN connection. Advantages n Security by VPN n Automatic generation of router configuration n Only outgoing connections towards Wie-Service24 are necessary n No changes inside the local network is necessary n Interconnection of complete networks, without additional routing configuration n Little coordination with IT department and easy commissioning n Mobile access by Smartphone or tablet to all devices behind the router n directRemote: Direct access with all internet browser by a clearly URL 60 wienet Wie-Service24 VPN Service Portal All machines online! Wie-Service24 LAN-TO-LAN Machines or plants Technician Mobile router Technician Machines or plants SMS information The Wie-Service24 VPN service portal is available in different configurations: You can try the working with the VPN-server Wie-Service24 with up to 30 routers and one PC client for free. If you need further VPN clients you can rent more router and PC clients. We propose the installation of your own customer VPN server portal. Installation of the portal on a virtual machine, on an industrial PC, data center at customer site or a data center on an internet server. Single access Virtual machine Industrial PC Data center Server at Customer Data center Internet server ZD.000.0011.0 (Router) ZD.000.0011.1 (PC-Client) ZD.000.0012.0 ZD.000.0013.0 (Energy Saving) ZD.000.0014.0 (High Performance) ZD.000.0015.0 .00 .0016.0 ZD.000.0016.0 User access * * * * * Administrator access - * * * * Server hardware from Wieland Customer Wieland Customer Provider Internet connection by Wieland Customer Customer Customer Provider Installation by Wieland Customer or Wieland Wieland Wieland Wieland Part-No. More information is available from our technical support: Telefon +49 9 51 93 24-995 Telefax +49 9 51 93 26-991 wie-service24@wieland-electric.com 61 62 interface flare Coupling relays The safe way to achieve a perfect interface in process applications. In the microchip age of bits and bytes, one might assume that there is no place left for electromechanical relays. Far from it! In control, transportation and production technology, coupling relays have been reliably accomplishing important tasks for years, and continue to do so. Together with control systems, they offer numerous possibilities of making your application even safer and less sensitive to disturbances. Advantages: n Safe galvanic separation n Pluggable and compact solutions n Mounts directly onto a 35-mm DIN rail n Optional gold-plated contacts n Screw clamp and tension spring termination n Display and EMI suppression modules n Also suitable for railway applications acc. to EN 50155 63 flare MOVE Coupling relays flare MOVE * Pluggable coupling relay * Overall width 6.2 mm * Screw terminals * 1 change-over contact 6A flare MOVE * Pluggable coupling relay * Overall width 15.8 mm * Screw terminals * 1 change-over contact 16A * 2 change-over contacts 8A 64 Description Part No. flare MOVE 12V Relay module DC 12V Relay module AC/DC 24V Relay module DC 24V Relay module AC/DC spring clamp con. 24V Relay module AC/DC 115V Relay module AC/DC 230V Relay module AC/DC Comb-shaped jumper 20pol. max 36A Marking plate BM SF38 Replacement relay and socket AgSnO2 80.010.4501.0 10 80.010.4521.0 10 80.010.4502.0 10 80.010.4622.0 10 80.010.4522.0 10 80.010.4525.0 10 80.010.4526.0 10 80.063.4029.1 10 80.063.4129.3 1 Information on request Std. Pack Part No. Std. Pack Technical data Maximum switching voltage Maximum switching current Maximum starting current Mechanical life Electrical life up to 230 V AC / 6A Isolation voltage of input / output Connectable via pluggable jumper Wire range fine-stranded/solid Degree of protection / Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 400 V AC 6 A AC/DC 10 A 1 x 107 6 x 10 4 4 kV eff 20 modules 0.14 -1.5 mm2 (AWG 26 - 16) / 0.5 - 2.5 mm2 (AWG 22 - 14) IP 20 / TS35 6.2 x 88 x 76 0 ... +50 C AgSnO2 + gold (5) 80.010.4501.1 10 80.010.4521.1 10 80.010.4502.1 10 80.010.4522.1 80.010.4525.1 80.010.4526.1 10 10 10 AK w Description Part No. flare MOVE 12V Relay module DC 24V Relay module DC 24V Relay module AC 115V Relay module AC 230V Relay module AC Comb-shaped jumper 8pol. for A1, A2 max 10A Marking tag BZ SF-48 Replacement relay 1 change-over contact 80.010.4901.3 10 80.010.4902.3 10 80.010.4912.3 10 80.010.4915.3 10 80.010.4916.3 10 80.063.5029.2 10 80.063.5029.3 10 Information on request Technical data Maximum switching voltage Maximum switching current Maximum starting current Mechanical life DC / AC Electrical life AC 1 Isolation voltage of input / output Connectable via pluggable jumper Wire range fine-stranded/solid Degree of protection / Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 400 V AC 250 V AC 16 A / (10 A up to 12 V) 8A 30 A / (20 A up to 12 V) 15 A 7 7 2 x 10 / 1 x 10 2 x 107 2 x 105 / 1 x 105 1 x 105 4 kV 8 modules 0.25 - 4 mm2 (AWG 24 - 12) / 0.25 - 6 mm2 (AWG 24 - 10) IP 20 / TS35 15.8 x 78.6 x 76 -40 ... +70 C A Kw Std. Pack Part No. Std. Pack 2 change-over contacts 80.010.5501.2 10 80.010.5102.2 10 80.010.5315.2 80.010.5316.2 10 10 flare MOVE Coupling relays flare MOVE MR * Pluggable coupling relay * Robust pins * Switching position is indicated mechanically * Lockable test button * For railway application accord. to EN 50 155 * Overall width 15.8 mm * Screw terminals * 1 change-over contact 16A * 2 change-over contacts 8A flare MOVE MR * Pluggable coupling relay * Robust pins * Switching position is indicated mechanically * Lockable test button * For railway application accord. to EN 50 155 * Overall width 15.8 mm * Cage clamp * 1 change-over contact 16A * 2 change-over contacts 8A flare MOVE MR * Pluggable coupling relay * Robust pins * Switching position is indicated mechanically * Lockable test button * For railway application accord. to EN 50 155 * Overall width 27 mm * Screw terminals * 4 change-over contacts 7A Description Part No. flare MOVE MR 24V Relay module DC 24V Relay module DC with gold (5m) Replacement relay Comb-shaped jumper 8 pole for A1, A2 max 10A Marking plate BM MR-4C 1 change-over contact 80.010.6002.2 10 80.010.6002.3 10 Information on request 80.063.5029.2 10 80.063.6029.3 10 Std. Pack Part No. Std. Pack Technical data Maximum switching voltage Maximum switching current Maximum starting current Mechanical life Electrical life AC 1 Isolation voltage of input / output Wire range fine-stranded/solid Degree of protection / Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 440 V AC 440 V AC 16 A 8A 25 A 15 A 7 1 x 10 1 x 107 1 x 105 1 x 105 6 kV 0.25 - 4 mm2 (AWG 24 - 12) / 0.25 - 6 mm2 (AWG 24 - 10) IP 20 / TS35 15.8 x 82.9 x 68.1 -40...+70 C (>12A max 50 C) -40 ... +70 C Description Part No. flare MOVE MR 24V Relay module DC 24V Relay module DC with gold (5m) Replacement relay Marking plate BM MR-4C 1 change-over contact 80.010.6102.2 10 80.010.6102.3 10 Information on request 80.063.6029.3 10 2 change-over contacts 80.010.6132.2 10 80.010.6132.3 Technical data Maximum switching voltage Maximum switching current Maximum starting current Mechanical life Electrical life AC 1 Isolation voltage of input / output Wire range fine-stranded/solid Degree of protection / Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 400 V AC 16 A 25 A 1 x 107 1 x 105 6 kV 0.2 - 1.5 mm2 (AWG 24 - 16) IP 20 / TS35 15.8 x 82.9 x 68.1 -25...+70 C (>12A max 50 C) 400 V AC 8A 15 A 1 x 107 1 x 105 2 change-over contacts 80.010.6032.2 10 80.010.6032.3 A Kw Std. Pack Part No. Std. Pack -25 ... +70 C A Kw Description Part No. flare MOVE MR 24V Relay module DC Replacement relay 4 change-over contact 80.010.5702.2 Information on request Std. Pack Technical data Maximum switching voltage Maximum switching current Maximum starting current Mechanical life Electrical life AC 1 Isolation voltage of input / output Wire range fine-stranded/solid Degree of protection / Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 250 V AC 7A 15 A 2 x 107 1.5 x 105 3.6 kV 0.25 - 4 mm2 (AWG 24 - 12) / 0.25 - 6 mm2 (AWG 24 - 10) IP 20 / TS35 27 x 76 x 86.9 -40 ... +70 C 10 A Kw 65 flare Coupling relays flare * Compact coupling relay * Overall width 6.2 mm * Screw terminals/ Cage clamp * 1 change-over contact 6 A Description Part No. flare MOVE 12V Relay module DC 24V Relay module DC 115V Relay module AC 230V Relay module AC Pluggable jumper max 2A Jumper for potential distribution red Jumper for potential distribution blue Endcaps for jumper, red Endcaps for jumper, blue 8 digit marking tag, unmarked, 60 pcs. Screw terminal Technical data Maximum switching voltage Maximum switching current Maximum starting current Mechanical life Electrical life up to 230V AC / 6A Isolation voltage of input / output Connectable via pluggable jumper Wire range fine-stranded/solid Degree of protection / Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals flare * Compact coupling relay * Overall width 6.2 mm / 12.4 (2 change-over contacts) * Screw terminals/ Cage clamp * Special Type Description Degree of protection / Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 66 80.010.4000.0 10 Z8.000.0200.8 Z8.000.0202.3 Z8.000.0202.4 Z8.000.0202.1 Z8.000.0202.2 Z4.242.5153.0 10 5 5 20 20 10 Part No. Cage clamp 80.010.4106.0 80.010.4100.0 80.010.4131.0 80.010.4141.0 Std. Pack 10 10 10 10 250 V AC / 300 V DC 6 A AC / 2A DC 10 A 1 x 107 8 x 10 4 4 kV eff 50 modules 0.5 -2.5 mm2 (AWG 22 - 14) / 0.25 -1.5 mm2 (AWG 24 - 16) / 0.25 - 4 mm2 (AWG 24 - 12) 0.25 - 2.5 mm2 (AWG 24 - 14) IP 20 / TS35 6.2 x 89 x 70 0 ... +60 C Aq w h Part No. flare Screw terminal 80.010.4005.0 24V Relay module AC/DC 1 change-over contact DC 48V 20mA with gold (3m) 24V Relay module DC 2 change-over contact AC 250V 6A AC/DC 300 V 2A DC 24V Knife edge disconnect relay AC/DC 1 change-over contact AC 250V 6A / DC 300 V 2 A 24V HAND-0-AUTO-Relay 1 normally open contact AC 250V 6A / DC 300V 2A Technical data Mechanical life Electrical life up to 230V AC / 6A Isolation voltage of input / output Connectable via pluggable jumper Wire range fine-stranded/solid Std. Pack Std. Pack 10 Part No. Std. Pack Cage clamp 80.010.4105.0 10 80.010.4103.0 5 80.010.4120.0 10 80.010.4101.0 10 2 x 107 6 x 10 4 4 kVeff 50 modules 0.5 -2.5 mm2 (AWG 22 - 14) / 0.25 -1.5 mm2 (AWG 24 - 16) / 0.25 - 4 mm2 (AWG 24 - 12) 0.25 - 2.5 mm2 (AWG 24 - 14) IP 20 / TS35 6.2 x 89 x 70 / 12.4 x 89 x 70 (2 change-over contacts) 0 .... +60 C 6 mm2 Aq w h flare Coupling relays Relay output modules * Pluggable coupling relay * Screw terminals * 1 change-over contact / 2 change-over contacts * 1 relay up to 16 relays * 5 A switching capacity per output * 12 V and 24 V Relay output modules * Pluggable coupling relay * Screw terminals * 1 change-over contact 4 A / 2 change-over contacts 5 A * 1 relay up to 8 relays * 115 V and 230 V AC/DC Description Part No. Relay output modules 12V Module AC/DC 1 relay 24V Module DC 4 relay positive switching 24V Module DC 4 relay negative switching 24V Module DC 8 relay positive switching 24V Module DC 16 relay positive switching Replacement relay 1 change-over contact 87.220.7553.0 10 87.220.1853.0 1 87.221.5553.0 1 87.220.1953.3 1 87.220.2253.3 1 Z8.000.0056.9 10 Std. Pack Part No. Std. Pack Technical data Maximum switching voltage Maximum switching current Maximum starting current Mechanical life Electrical life 230V AC / 5A Isolation voltage of input / output Wire range fine-stranded/solid Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 250 V AC/DC 5 A AC/DC 8 A AC/DC 3 x 107 6 x 105 4 kV 0.25 - 2.5 mm (AWG 24 - 14) / 0.5 - 4 mm2 (AWG 22 - 12) TS 35 / TS 32 1 relay:12.5 x 80 x 58.3 4/8/16 relay: 70/128/280 x 80 x 71 -25 ... +50 C (Derating) 2 change-over contacts 87.220.4753.3 1 87.220.4853.3 1 Z8.000.0035.5 10 A Description Part No. Relay output modules 230 V Module AC/DC 1 relay 115 V Module AC/DC 4 relay 115 V Module AC/DC 8 relay 230 V Module AC/DC 4 relay 230 V Module AC/DC 8 relay Replacement relay 1 change-over contact 80.010.0011.0 10 80.010.1102.0 1 80.010.1110.0 1 80.010.1106.0 1 80.010.1114.0 1 Z8.000.0181.0 10 Std. Pack Part No. Std. Pack Technical data Maximum switching voltage Maximum switching current Maximum starting current Mechanical life Electrical life 230V AC / nominal current Isolation voltage of input / output Wire range fine-stranded/solid Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 250 V AC/DC 4 A AC/DC 5 A AC/DC 6 A AC/DC 6 A AC/DC 7 3 x 10 1.5 x 10 6 4 kV 0.25 - 2.5 mm (AWG 24 - 14) / 0.5 - 4 mm2 (AWG 22 - 12) TS 35 / TS 32 1 relay: 12.5 x 80 x 70 4/8 relay: 70/128 x 80 x 71 -40 ... +50 C (Derating) 2 change-over contacts 80.010.1100.0 5 80.010.1104.0 1 80.010.1112.0 1 80.010.1108.0 1 80.010.1116.0 1 Z8.000.0176.2 10 A 67 flare Coupling relays Relay system * Bridgeable relay system * Screw terminals * 1 normally open contact/ 1 change-over contact * 24 V AC/DC Relay system * Bridgeable relay system * Screw terminals * 2 change-over contacts 5 A * 24 V AC/DC Relay system * Bridgeable relay system * Screw terminals * 1 change-over contact 16 A * 24 V AC/DC 68 Description Part No. Relay system 24 V Module AC/DC 1 normally open contact 24 V Module AC/DC 1 change-over contact Pluggable jumper max. 0.5A Output 80.010.0005.0 80.010.0008.0 Z8.000.0103.4 Technical data Maximum switching voltage Maximum switching current Maximum starting current Mechanical life Electrical life (up to nominal rating) Isolation voltage of input / output Wire range fine-stranded/solid Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 250 V AC/DC 48 V DC (10 m gold) 5 A AC/DC 20 mA 8 A AC/DC 7 3 x 10 3 x 107 2.5 x 105 3 x 10 6 4 kV 0.5 - 2.5 mm (AWG 22 - 14) / 0.5 - 4 mm2 (AWG 22 - 12) TS 35 / TS 32 12.5 x 80 x 60 -25 ... +50 C (Derating up to 65 C) Description Part No. 10 10 10 Part No. Input 80.010.0007.0 80.010.0009.0 Std. Pack 10 10 AlE w Relay system Output 24 V Module AC/DC 2 change-over contacts 80.010.1003.0 Z8.000.0103.4 Pluggable jumper max. 0.5 A Technical data Maximum switching voltage Maximum switching current Maximum starting current Mechanical life Electrical life (up to nominal rating) Isolation voltage of input / output Wire range fine-stranded/solid Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals Std. Pack Std. Pack 5 10 Part No. Input 80.010.1002.0 Std. Pack 5 250 V AC/DC 48 V DC (10 m gold) 5 A AC/DC 20 mA 6 A AC/DC 3 x 107 3 x 107 2.5 x 105 3 x 10 6 4 kV 0.5 - 2.5 mm (AWG 22 - 14) / 0.5 - 4 mm2 (AWG 22 - 12) TS 35 / TS 32 22.5 x 80 x 60 -25 ... +50 C AlE w Description Part No. Relay system 24 V Module AC/DC 1 change-over contact Pluggable jumper max. 0.5 A Output 80.010.0010.0 Z8.000.0103.4 Technical data Maximum switching voltage Maximum switching current Maximum starting current Mechanical life Electrical life (up to nominal rating) Isolation voltage of input / output Wire range fine-stranded/solid Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 250 V AC/DC 16 A AC/DC 16 A AC/DC 3 x 107 1.8 x 105 4 kV 0.5 - 2.5 mm (AWG 22 - 14) / 0.5 - 4 mm2 (AWG 22 - 12) TS 35 / TS 32 22.5 x 80 x 60 -25 ... +50 C (Derating up to 65 C) AlE w Std. Pack 5 10 flare Solid-State relays flare * Compact solid-state relay * Overal width 6.2 mm * Spring cage clamp * Output 48 V DC flare * Compact solid-state relay * Overal width 6.2 mm * Spring cage clamp * Output 230 V AC Solid-state relay * Bridgeable * Screw terminals * Output 60 V DC Solid-state relay * Bridgeable * Screw terminals * Output 250 V AC Description Part No. flare 24 V Module DC / Output 48 V 115 V Module AC/DC / Output 48 V 230 V Module AC/DC / Output 48 V Pluggable jumper max 2 A 8 digit marking tag, unmarked, 60 pcs. Output 0,5 A 80.020.4100.0 80.020.4102.0 80.020.4103.0 Z8.000.0200.8 Z4.242.5153.0 Std. Pack Technical data Maximum switching voltage Maximum switching current Min. switching current Isolation voltage of input / output Connectable via pluggable jumper Wire range fine-stranded/solid Degree of protection / Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 48 V DC (4,4...53 V DC) 0.5 A 2A 0.1 mA 1 mA 3.75 kV 50 modules 0.25 -1.5 (AWG 24 - 16) / 0.25 - 2.5 mm2 (AWG 24 - 14) IP 20 / TS35 6.2 x 89 x 70 0 .... +50 C (Derating) Description Part No. flare 24V Module DC / Output 230 V AC Pluggable jumper max 2 A 8 digit marking tag, unmarked, 60 pcs. Output 0,5 A 80.020.4150.0 Z8.000.0200.8 Z4.242.5153.0 Technical data Maximum switching voltage Maximum switching current Min. switching current Isolation voltage of input / output Connectable via pluggable jumper Wire range fine-stranded/solid Degree of protection / Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 250 V AC 0.5 A 0.1 mA 2.5 kV 50 modules 0.25 -1.5 mm (AWG 24 - 16) / 0.25 - 2.5 mm2 (AWG 24 - 14) IP 20 / TS35 6.2 x 89 x 70 0 ... +50 C (Derating) 10 10 10 10 10 Part No. Std. Pack Output 2 A 80.020.4101.0 10 Aq w h Std. Pack 10 10 10 Aq w h Description Part No. Solid-State-Relay 24 V Module DC / Output 48 V Pluggable jumper Output 3 A 80.020.2003.0 Z8.000.0103.4 Std. Pack Technical data Maximum switching voltage Maximum switching current Min. switching current Isolation voltage of input / output Connectable via pluggable jumper Wire range fine-stranded/solid Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 60 V DC (3...60 V) 3 A DC (Derating) 5 A DC 20 mA 4 kV 20 modules 0.5 -2.5 mm (AWG 22 - 14) / 0.5 - 4 mm2 (AWG 22 - 12) TS 35 / TS 32 12.5 x 80 x 64 12.5 x 80 x 59 -20 ... +50 C (Derating) 10 10 Part No. Output 5 A 80.020.2004.0 Std. Pack 10 AEw Description Part No. Solid-State-Relay 24 V Module DC / Output 250 V AC Pluggable jumper Output 4 A 80.020.2001.0 Z8.000.0103.4 Std. Pack Technical data Maximum switching voltage Maximum switching current Min. switching current Isolation voltage of input / output Connectable via pluggable jumper Wire range fine-stranded/solid Mounting rail Dimensions (mm) W x H x D Ambient temperature Approvals 280 V AC (48...280 V) 4A 6A 60 mA 4 kV 20 modules 0.5 -2.5 mm (AWG 22 - 14) / 0.5 - 4 mm2 (AWG 22- 12) TS 35 / TS 32 12.5 x 80 x 56 25.6 x 80 x 70 -25 ... +50 C (Derating) 10 10 Part No. Output 6 A 80.020.0004.0 Std. Pack 10 AEw 69 cores 70 cores Analog Isolation Amplifier flexible and precise Analog isolation amplifier of the cores series The Advantages: The cores series convinces with flexible use in process and industrial automation. * Highest accuracy (0.1 %) and linearity They ensure a defined separation of measurement and process signals from the control system. And it protects against voltage drops. Analogue isolation amplifiers also convert signals into standardized signal levels. * Digital conversion (up to 16 Bit) * Fastest reaction time (from 11 ms) * 3 or 4 way galvanic isolation * High isolation voltage * Compact housing (also as thin as 6.2 mm) * Universal functions settable * Wide temperature range cores combines a highly precise signal conversion with a very small housing and fulfils actual demands for such products. 71 cores Analog Isolation Amplifier cores C1 UI-B * Analog Isolation Amplifier * 3 way isolation * Input: voltage / current, output: voltage / current * High accuracy by digital conversion * Width 6.2 mm * Spring clamp connection * Wide temperature range Type cores C1 UI-B Techncal data Input range (adjustable) Output range (adjustable) Galvanic isolation Isolation voltage Accuracy Supply voltage range Power consumption Connection type Wire range solid/fine-stranded Degree of protection / Mounting rail Dimensions (mm) W x H x D Temperature range Approvals (pending) cores C1 PT-B * Analog Isolation Amplifier * 3 way isolation * Input: PT 100, output: voltage / current * High accuracy by digital conversion * Width 6.2 mm * Spring clamp connection * Wide temperature range Type cores C1 PT-B Technical data Input range (adjustable) Output range (adjustable) Galvanic isolation Isolation voltage Accuracy Supply voltage range Power consumption Connection type Wire range solid/fine-stranded Degree of protection / Mounting rail Dimensions (mm) W x H x D Temperature range Approvals (pending) cores C1 TC-B * Analog Isolation Amplifier * 3 way isolation * Input: thermo coupler, output: voltage / current * High accuracy by digital conversion * Width 6.2 mm * Spring clamp connection * Wide temperature range Type cores C1 TC-B Technical data Input range (adjustable) Output range (adjustable) Galvanic isolation Isolation voltage Accuracy Supply voltage range Power consumption Connection type Wire range solid/fine-stranded Degree of protection / Mounting rail Dimensions (mm) W x H x D Temperature range Approvals (pending) 72 Part No. 82.003.0110.0 0/1 ... 5 V DC or 0/2 ... 10 V DC 0/4 ... 20 mA DC 0/1 ... 5 V DC or 0/2 ... 10 V DC 0/4 ... 20 mA DC or 20 ... 4/0 mA DC active or passive yes, 3 way isolation 1500 V AC <0.1%, 14 Bit resolution 19.2 ... 30 V DC max. 500 mW Spring clamp 0.2 - 2.5 mm (AWG 24 - 14) IP 20 / TH 35 (EN60715) 6.2 x 93.1 x 102.5 -20 ... +65 C AE Part No. 82.003.0120.0 PT100 with 2-, 3- or 4 wire connection -150 ... +650 C 0/1 ... 5 V DC or 0 ... 10 V; 10 ... 0 V DC 0/4 ... 20 mA DC or 20 ... 4/0 mA DC yes, 3 way isolation 1500 V AC <0.1%, 14 Bit resolution 19.2 ... 30 V DC max. 500 mW Spring clamp 0.2 - 2.5 mm (AWG 24 - 14) IP 20 / TH 35 (EN60715) 6.2 x 93.1 x 102.5 -20 ... +65 C AE Part No. 82.003.0130.0 Types of thermo coupler: J, K, E, N, S, R, B, T 0/1 ... 5 V DC oder 0 ... 10 V DC 0/4 ... 20 mA DC oder 20 ... 4/0 mA DC yes, 3 way isolation 1500 V AC <0.1%, 14 Bit resolution 19.2 ... 30 V DC max. 500 mW Spring clamp 0.2 - 2.5 mm (AWG 24 - 14) IP 20 / TH 35 (EN60715) 6.2 x 93.1 x 102.5 -20 ... +65 C AE cores Analog Isolation Amplifier cores C2 UI-A * Analog Isolation Amplifier * 3 way isolation * Input: current, output: current * High accuracy by digital conversion * Width 17.5 mm * Screw clamp pluggable * Wide temperature range Type cores C2 UI-A 82.003.0210.0 Technical data Input range (adjustable) Output range (adjustable) Galvanic isolation Isolation voltage Accuracy Reaction time Supply voltage range Power consumption Connection type Wire range solid/fine-stranded Degree of protection / Mounting rail Dimensions (mm) W x H x D Temperature range 0 ... 20 mA DC active or passive 0 ... 20 mA DC active or passive yes, 3 way isolation 1500 V AC <0.1% <40 ms 9 ... 40 V DC, 19 ... 28 V AC max. 2.5 W Screw clamp pluggable 0.14 - 2.5 mm (AWG 26 - 14) IP 20 / TH 35 (EN60715) 17.5 x 100 x 112 -20 ... +60 C Approvals (pending) cores C2 M-A * Analog Isolation Amplifier * 3 way isolation * Input: voltage, current, thermo coupler, potentiometer, output: voltage, current * High accuracy by digital conversion * Width 17.5 mm * Screw clamp pluggable * Wide temperature range Type cores C2 M-A Technical data Input range (adjustable) Output range (adjustable) Galvanic isolation Isolation voltage Accuracy Reaction time Supply voltage range Power consumption Connection type Wire range solid/fine-stranded Degree of protection / Mounting rail Dimensions (mm) W x H x D Temperature range Approvals (pending) cores C2 M2-A * Analog Isolation Amplifier * 4 way isolation * 2 analogue outputs * Input: voltage, current, thermo coupler, potentiometer, output: voltage, current * High accuracy by digital conversion * Width 17.5 mm * Screw clamp pluggable * Wide temperature range Part No. Type cores C2 M2-A Technical data Input range (adjustable) Output range (adjustable) Galvanic isolation Isolation voltage Accuracy Reaction time Supply voltage range Power consumption Connection type Wire range solid/fine-stranded Degree of protection / Mounting rail Dimensions (mm) W x H x D Temperature range Approvals (pending) AE Part No. 82.003.0200.0 75 mV ... 20 V in 9 ranges (bipolar) 0 ... 20 mA (bipolar) J,K,R,S,T,B,E,N Thermo coupler Pt100, Pt500, Pt1000, Ni100. 3 or 4 wire 500 Ohm ... 10 kOhm Potentiometer 500 Ohm ... 25 kOhm Rheostat 0 ... 20 mA oder 4 ... 20 mA 0 ... 5 V oder 0 ... 10 V oder 1 ... 5 V oder 2 ... 10 V yes, 3 way isolation 1500 V AC <0.1%, 12 or 16 Bit resolution <35 ms (at 12 Bit) and <140 ms (at 16 Bit) 10 ... 40 V DC, 19 ... 28 V AC max. 2.5 W Screw clamp pluggable 0.14 - 2.5 mm (AWG 26 - 14) IP 20 / TH 35 (EN60715) 17.5 x 100 x 112 -10 ... +60 C AE Part No. 82.003.0250.0 0 ... +10V 0 ... 20mA active or passive J, K, R, S, T, B, E, N Thermo coupler Pt100, Pt500, Pt1000, Ni100. 2, 3, 4 wire 1 ... 100 kOhm Potentiometer 500 Ohm ... 25 kOhm Rheostat 0 ... 20 mA or 4 ... 20 mA active or passive 0 ... +10 V yes, 4 way isolation 1500 V AC <0.1%, 14 Bit resolution <11 ms 10 ... 40 V DC, 19 ... 28 V AC max. 2 W Screw clamp pluggable 0.14 - 2.5 mm (AWG 26 - 14) IP 20 / TH 35 (EN60715) 17.5 x 100 x 112 -10 ... +65 C AE 73 74 flare TIME Timers Always up to the minute The electronic relays are ideally suited for standard, monitoring and control tasks in order to control function processes down to the second. Depending on the application, multiple-voltage and multi-functional relays are available. Decades of timer know-how are packed into a completely new, highly miniaturized generation of timers just 22.5 mm wide. Although the end of the timer has been being predicted for years now, as the PLC has spread, high quality timers with well thoughtout designs and universal application will continue to be needed in industrial automation. Timers remain crucial - in less complex series machines, in later modifications, everywhere where other solutions would result in unnecessary engineering and hardware costs. For these applications Wieland offers a range of timers that provides everything you need. These devices unite diverse features with an efficiency that permits the fullest profitability - from procurement and warehousing through application and operation, and finally to disposal. 75 flare TIME Variable input voltage The activation of the excitation input B1 can be done with any voltage levels from AC/DC 20.4 V to 264 V. Remote Control (optional) Connecting an optional remote potentiometer means that a number of devices can be time-setting enabled over large distances without requiring access to the control cabinet. Operation without a remote potentiometer does not require a bridge at the relay. Assembly 1. Hook the housing onto the DIN rail 2. Snap the housing onto the DIN rail by gently pressing it in the direction of the arrow 76 Disassembly 1. Press down the housing in the direction of the arrow 2. Release the housing from its latched position by holding it down and moving it in the direction of the arrow, and remove it from the DIN rail flare TIME Multiple-voltage ergonomic and mobile flare TIME series of timer relays The advantages: Our flare TIME family features universal application in the industrial automation sector. Up to 8 functions in just one relay cover all of your requirements and reduce inventory costs as well. Existing production processes can be easily expanded thanks to our flare TIME timer relay series, without incurring additional engineering and hardware costs. Our timer relays can be used in bakery machines, industrial washing machines, elevators and escalators, access controls and much more. Power LED with progress display Function setting Time range setting Clear time setting LED as status indicator of the change-over contact Double connection points internally connected (HM series) Features: Ambient temperatures from -25 C to +60 C Very high interference voltage resistance Output relays correspond to utilization category AC-15 and DC-13 77 flare TIME Electronic timer and switching relays for DIN rails Electromechanical timer and switching relays for DIN rails Electronic timer and switching relays for panel mounting Electromechanical timer and switching relays for panel mounting ! 78 Further products and technical details can be found at www.wieland-electric.com in our e-catalog. flare TIME Electronic timer and switching relays for DIN rails Multifunction flare TIME HM8-2-A flare TIME HM8-2P-A flare TIME HM5-1-A flare TIME M8-2 flare TIME M8-1 flare TIME M4-2 flare TIME M4-1 flare TIME-S 81.020.0104.0 81.020.0134.0 81.020.0100.0 81.020.0003.0 81.020.0002.0 81.020.0001.0 81.020.0000.0 81.020.4100.0 Description Multi-function Multi-range * * * * * * * * * * * * * * * ON-delay OFF-delay * * * * * * * * * * * * * ON-delay- and OFF-delay, symmetrical * * * * Interval ON Interval OFF Interval ON and Interval OFF OFF start, symmetrical and selectable ON start, symmetrical and selectable * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 2 2 1 1 * * * * 21) 11) * 1 * 21) 11) * A * A * A * A * Part no. Model Function Timer relays Interval ON relay Repeat cycle timer ON start, symmetrical and fixed OFF start and ON start, symmetrical and fixed, cycle time setting range Star-delta relay Switch-over relay, Interval ON Pulse relay Contacts Rated Voltage Special Features Housing Pulse relay, ON-delay, Pulse output Pulse relay, OFF start, OFF start selectable, ON time fixed Pulse relay, alternating, OFF or ON time selectable One shot (interval ON) Timed change-over contact Instantaneous change-over contact Multi-voltage AC/DC 24 to 230 (240) V Remote potentiometer connection Double connection points (internally connected) for trough cabling Digital (D) or analog (A) settings Surface mounting 22.5 mm * * * A * A * A * 1 * 1) = 1 timed and 1 instantaneous change-over contact or 2 timed change-over contacts, selectable 79 flare TIME Electronic timer and switching relays for DIN rails flare TIME M * Multi-function timer * Multi-range time * Wide input voltage range 20.4 ... 264 V AC/DC * 4 or 8 selectable time functions * 1 or 2 change-over contacts 5 A flare TIME HM * Multi-function timer * Multi-range time * Wide input voltage range 20.4 ... 264 V AC/DC * 5 or 8 selectable time functions * Pluggable clamps * Wide temperature range * 1 or 2 change-over contacts 5 A flare TIME TWIN-1 * Multi-range repeat cycle timer * Multi-range time * ON- or OFF-start settable * Time ON and OFF seperate adjustable * Wide input voltage range 20.4 ... 264 V AC/DC * 1 change-over contacts 5 A 80 Type Part No. flare TIME M4-1 (4 time ranges / 1 contacts) flare TIME M4-2 (4 time ranges / 2 contacts) flare TIME M8-1 (8 time ranges / 1 contacts) flare TIME M8-2 (8 time ranges / 2 contacts) 81.020.0000.0 81.020.0001.0 81.020.0002.0 81.020.0003.0 Technical data Input voltage range Time range Time functions Number of change-over contacts Maximum switching current Mechanical life time Electrical life time AC1 Isolation voltage of input/output Connection clamps Wire range fine-stranded/solid Degree of protection / mounting rail Dimensions (mm) W x H x D Operation temperature range Approvals 20,4 ... 264 V AC/DC 0.1 s ... 1200 h 4 or 8 1 or 2 5A 10 x 10 6 0.1 x 10 6 2 kV Screw clamp 0.14 - 2.5 mm (AWG 26 - 14) IP 20 / TH 35 (EN60715) 22.5 x 89.4 x 100 -20 ... +55 C Type AK Part No. flare TIME HM5-1-A (5 time ranges / 1 contacts) 81.020.0100.0 flare TIME HM8-2-A (8 time ranges / 2 contacts) 81.020.0104.0 flare TIME HM8-2P-A (with remote control connection) 81.020.0134.0 Technical data Input voltage range Time range Time functions Number of change-over contacts Maximum switching current Mechanical life time Electrical life time AC1 Isolation voltage of input/output Connection clamps Wire range fine-stranded/solid Degree of protection / mounting rail Dimensions (mm) W x H x D Operation temperature range Approvals 20,4 ... 264 V AC/DC 0.05 s ... 240 h 5 or 8 1 or 2 5A 20 x 10 6 0.1 x 10 6 2 kV Pluggable screw clamp 0.2 - 2.5 mm (AWG 24 - 14) IP 20 / TH 35 (EN60715) 22.5 x 96.5 x 81.5 -25 ... +60 C AE Type Part No. flare TIME TWIN-1 81.020.0011.0 Technical data Input voltage range Time range Time functions Number of change-over contacts Maximum switching current Mechanical life time Electrical life time AC1 Isolation voltage of input/output Connection clamps Wire range fine-stranded/solid Degree of protection / mounting rail Dimensions (mm) W x H x D Operation temperature range Approvals 20,4 ... 264 V AC/DC 0.1 s ... 1200 h ON- or OFF-start 1 5A 10 x 10 6 0,1 x 10 6 2 kV Screw clamp 0.14 - 2.5 mm (AWG 26 - 14) IP 20 / TH 35 (EN60715) 22.5 x 89.4 x 100 -20 ... +55 C AK flare TIME Electronic timer and switching relays for DIN rails flare TIME OFF-1 * OFF delayed timer * No auxiliary voltage necessary * 2 time ranges setable * 1 change-over contacts 5 A flare TIMER-S * Multi-function timer * ON-delay and OFF-delay * One shot and flashing * Spring clamp * Width 6.2 mm * 1 change-over contacts 6 A Type Part No. flare TIME OFF-1 81.020.0010.0 Technical data Input voltage range Time range Time functions Number of change-over contacts Maximum switching current Mechanical life time Electrical life time AC1 Isolation voltage of input/output Connection clamps Wire range fine-stranded/solid Degree of protection / Mounting rail Dimensions (mm) W x H x D Operation temperature range Approvals 170 ... 264 V AC 1 ... 120 s OFF delay 1 5A 10 x 10 6 0.1 x 10 6 2 kV Screw clamp 0.14 - 2.5 mm (AWG 26 - 14) IP 20 / TH 35 (EN60715) 22.5 x 89.4 x 100 -20 ... +55 C Type Part No. flare TIMER-S-250250V6A 81.020.4100.0 Technical data Input voltage range Time range Number of change-over contacts Maximum switching current Mechanical life time Electrical life time at 24 V DC / 2 A Electrical life time at 230 V AC / 6 A Isolation voltage of input/output Connection clamps Wire range fine-stranded/solid Degree of protection / Mounting rail Dimensions (mm) W x H x D Operation temperature range Approvals flare TIMER-A * Timer * ON-delay * Spring clamp * Width 6.2 mm * 1 change-over contacts 6 A AK 24 V DC +25%/-20% 0.1 ... 300 s 1 6A 2 x 107 0.6 x 10 6 0.8 x 105 4 kV Spring clamp 0.25 - 1.5 mm (AWG 24-16) / 0.25 - 2.5 mm (AWG 24-14) IP 20 / TH 35 (EN60715) 6,2 x 89 x 70mm 0 ... +50 C wh Type Part No. flare TIMER-A /0100-S-250V6A flare TIMER-A /0060-S-250V6A 81.020.4101.0 81.020.4102.0 Technical data Input voltage range Time range TIMER A/0100 Time range TIMER A/0060 Number of change-over contacts Maximum switching current Mechanical life time Electrical life time at 24 V DC / 2 A Electrical life time at 230 V AC / 6 A Isolation voltage of input/output Connection clamps Wire range fine-stranded/solid Degree of protection / Mounting rail Dimensions (mm) W x H x D Operation temperature range Approvals 24 V DC +25%/-20% 1 ... 100 s 1 ... 100 min 1 6A 2 x 107 0.6 x 10 6 0.8 x 105 4 kV Spring clamp 0.25 - 1.5 mm (AWG 24-16) / 0.25 - 2.5 mm (AWG 24-14) IP 20 / TH 35 (EN60715) 6,2 x 89 x 70mm 0 ... +50 C wh 81 flare TIME Electromechanical Timer and switching relays for DIN rails ON-delay multi-range electromechanical timer relays SZA 52-S / SZA 52 / SZAN 52-S / SZA 54-2S * Devices for single voltage * Function: ON-delay (AV), SZAN 52-S protected against power failure * 1 setting range divided into 6 time ranges * Contact assignment: SZA 52-S = 1 timed and 1 instantaneous change-over contact SZAN 52-S = 1 timed and 1 instantaneous change-over contact SZA 52 = 2 timed change-over contact SZA 54-2S = 1 timed and 1 instantaneous normally closed contact (NC) 1 timed and 1 instantaneous normally open contact (NO) OFF-delay multi-range electromechanical timer relay with auxiliary supply, SZA 521 * Devices for single voltage Electromechanical multi-range repeat cycle timer SPZA 52 * Function: repeat cycle timer (TI) starting with ON * function: OFF-delay (RV) * 1 setting range divided into 6 time ranges * Contact assignment: 1 timed and 1 instantaneous change-over contact * ON and OFF times can be selected independently of one another * 1 setting range divided into 6 time ranges * Contact assignment: 1 normally open, 1 normally closed Electromechanical stepping relay SSF 32 / SSF 52 / SSF 62 * Devices for single voltage * Function: stepping relay * Contact assignment: SSF 32 = 2 NO contacts, simultaneously switched in an ON-OFF cycle SSF 52 = 1 NO contact and 1 NC contact, reciprocally switched in an ON-OFF cycle SSF 62 = 1 NO contact and 1 NC contact, reciprocally switched in an ON-OFF cycle Electromechanical latching relay SSP 56 / SSP 72 / SSP 33 / SSP 34 * Devices for single voltage * Function: Latching relay * Contact assignment: SSP 56 = 3 NO contact and 3 NC contact SSP 72 = 2 change-over contact SSP 33 = 3 change-over contact SSP 34 = 4 change-over contact 82 Detailled information can be found in our e-catalogue at http://eshop.wieland-electric.com Type at search the product family name, e. g. SZA521 (without blank) flare TIME Electronic timer and switching relays for panel mounting flare TIME FM15-1 * Multi-function timer * High-contrast color display * 15 time functions * Front panel mounting 48 x 48 mm * Wide temperature range * 1 change-over contact 5 A Type Part No. flare TIME FM15-1 (24 V) flare TIME FM15-1 (230 V) 81.020.0020.0 Technical data Input voltage range Time range Time functions Number of change-over contacts Maximum switching current Mechanical life time Electrical life time AC1 Isolation voltage of input/output Connection clamps Wire range fine-stranded/solid Degree of protection Dimensions (mm) W x H x D Operation temperature range Approvals 81.020.0021.0 4.5...30 V DC 85...264 V AC/DC 0.001 s ... 999 h 15 1 5A 10 x 10 6 0.1 x 10 6 2 kV Screw clamp 0.14 - 2,5 mm (AWG 26 - 14) IP20 / IP 66 (optional) 48 x 48 x 65 48 x 48 x 85,5 -10 ... +55 C AE 83 flare TIME Electromechanical timer and switching relays for panel mounting ON-delay single-range timer relay, electromechanical DZ 12-S L*) / DZN 12-S L * Devices for single voltage * Function: ON-delay (AV), DZN 12-S L protected against power failure * 1 time range * Contact assignment: 1 timed and 1 instantaneous change-over contact * Cover: 72 x 72 mm * Panel cutout: 68 mm * Push-on connections 6.3 mm ON-delay multi-range electromechanical timer relay DZ 52-S G * Device for single voltage * Function: ON-delay (AV) * 1 Setting range, divided into 5 oder 6 time ranges * Contact assignment: 1 timed change-over contact and 1 instantaneous NO contact * Cover: 72 x 72 mm * Panel cutout: 68 mm ON-delay multi-range electromechanical timer relay, for burner control system DZR 52-S L * Device for single voltage * Function: ON-delay (AV) for burner control system * 1 Setting range divided into 5 or 6 time ranges * Contact assignment: 1 timed and 1 instantaneous change-over contact * Cover: 72 x 72 mm * Panel cutout: 68 mm * Push-on connections 6.3 mm ON-delay multi-range electromechanical timer relay DZ 52-S L / DZN 52-S L * Devices for single voltage * Function: ON-delay (AV), DZN 52-S L protected against power failure * 1 setting range divided into 5 or 6 time ranges * Contact assignment: 1 timed and 1 instantaneous change-over contact * Cover: 72 x 72 mm * Panel cutout: 68 mm * Push-on connections 6.3 mm ON-delay multi-range electromechanical timer relay DZA 52-S L / DZA 53-S L DZAN 52-S L / DZA 52 L * Devices for single voltage * Function: ON-delay (AV), DZAN 52-S L protected against power failure * 1 setting range divided into 6 time ranges * Contact assignment: DZA 52-S L = 1 timed and 1 instantaneous change-over contact DZAN 52-S L = 1 timed and 1 instantaneous change-over contact DZA 53-S L = 2 timed change-over contact and 1 instantaneous NO contact DZA 52 L = 2 timed change-over contact * Cover: 72 x 72 mm * Panel cutout: 68 mm * Push-on connections 6.3 mm 84 *Products with approval w flare TIME Electromechanical timer and switching relays for panel mounting ON-delay multi-range electromechanical timer relay DZ 74-2S L * Devices for single voltage * Function: ON-delay (AV) * 1 setting range divided into 6 time ranges * Contact assignment: 1 timed NC contact, 1 instantaneous and 1 timed NO contact * without time accumulation * Cover: 96 x 96 mm * Panel cutout: 91 mm * Push-on connections 6.3 mm ON-delay multi-range electromechanical timer relay DZ 72-S / DZ 74-2S * Devices for single voltage * Function: ON-delay (AV) * 1 setting range divided into 5 or 6 time ranges * Contact assignment: DZ 72-S = 1 timed and 1 instantaneous change-over contact DZ 74-2S = 1 instantaneous and 1 timed NC contact, 1 instantaneous and 1 timed NO contact * Cover: 96 x 96 mm * Panel cutout: 91 mm ON-delay single-range electromechanical timer relay, for burner control system DZR 12-S L * Devices for single voltage * Function: ON-delay (AV) for burner control system * 1 time range * Contact assignment: 1 timed and 1 instantaneous change-over contact * Cover: 72 x 72 mm * Panel cutout: 68 mm * Push-on connections 6.3 mm OFF-delay multi-range electromechanical timer relay DZ 521 L * Devices for single voltage * Function: OFF-delay (RV) * 1 setting range divided into 5 or 6 time ranges * Contact assignment: 1 timed and 1 instantaneous change-over contact * Cover: 72 x 72 mm * Panel cutout: 68 mm * Push-on connections 6.3 mm OFF-delay multi-range electromechanical timer relay DZA 521 L * Devices for single voltage * Function: OFF-delay (RV) * 1 setting range divided into 6 time ranges * Contact assignment: 1 timed and 1 instantaneous change-over contact * Cover: 72 x 72 mm * Panel cutout: 68 mm * Push-on connections 6.3 mm * New housing concept Detailled information can be found in our e-catalogue at http://eshop.wieland-electric.com Type at search the product family name,. e. g. DZ12 (without blank) 85 86 flare CONTROL Measuring & control precise and safe Always live Electronic measuring and monitoring relays for measuring input values such as current, voltage, 3-phases, cos phi, temperature. They carry out both simple and complex monitoring in machines and systems. Features: The optimum device for every monitoring task Voltage, current, phase sequence, phase error, temperature or cos phi Broad temperature range Gold-plated switching contacts for maximum operational reliability 87 flare CONTROL Benefits * Upper and lower threshold separately adjustable * 3 measuring ranges (single phase) * Closed circuit or operating circuit principle * Time delay 0 ... 10 s adjustable * Wide input voltage range 20.4 ... 264 V AC/DC * Width 22.5 mm * Pluggable screw clamps * Wide temperature range 88 flare CONTROL Multi-functional measuring relay economical and flexible Measuring relays flare CONTROL The product family flare CONTROL convinces by the universal use in industrial automation. All functions required for measuring relays are combined in one device. Only one type for current and voltage measurement is necessary. This simplifies engineering and reduces stock. Features: 3 measuring ranges in one device Power LED Adjustable for closed circuit or operating circuit principle In additional also time delay for exceeding the threshold LED for exceedance of the threshold value One terminal for supply voltage Upper threshold in percent of measuring range Lower threshold in percent of upper threshold 2 change over contacts simultaneously switching, one change-over contact output per terminal 89 flare CONTROL Measuring relay flare CONTROL U-1-A * Multi-function measuring relay * Upper and lower threshold separately adjustable * 3 measurement ranges (single phase) * Signal shape DC and sinus * Closed circuit or operating circuit principle * Time delay at exceeding the threshold adjustable * Wide input voltage range 20.4 ... 264 V AC/DC * Width 22.5 mm * Pluggable screw clamps * Wide temperature range * 2 change-over contacts 5 A flare CONTROL I-1-A * Multi-function measuring relay * Upper and lower threshold separately adjustable * 3 measuring ranges (single phase) * Signal shape DC and sinus * Closed circuit or operating circuit principle * Time delay at exceeding the threshold adjustable * Wide input voltage range 20,4 ... 264 V AC/DC * Width 22.5 mm * Pluggable screw clamps * Wide temperature range * 2 change-over contacts 5 A 90 Type Part No. flare CONTROL U-1-A 81.030.0100.0 Technical data Measuring ranges Upper threshold Lower threshold Signal shape Nominal frequency of measured signal at AC Nominal power Supply voltage range Galvanic isolation toward supply Functions Time delay at exceeding the threshold Number of change-over contacts Maximum switching current Mechanical life time Electrical life time AC1 Isolation voltage of input/output Connection clamps Wire range fine-stranded/solid Degree of protection / mounting rail Dimensions (mm) W x H x D Operation temperature range Approvals 5 / 50 / 300 V 10...100 % of measuring range 50 ... 95 % of upper threshold DC and sinus 45 ... 400 Hz app. 2 W / 4 VA 20.4 ... 264 V AC/DC Yes Closed circuit or operating circuit principle 0 / 0.1 / 0.5 / 2 / 10 s 2 (simultaneously switching) 5A 20 x 10 6 0.1 x 10 6 2 kV Pluggable screw clamp 0.2 - 2.5 mm (AWG 24 - 14) IP 20 / TH 35 (EN60715) 22.5 x 96.5 x 114 -25 ... +55 C AE Type Part No. flare CONTROL I-1-A 81.030.0110.0 Technical data Measuring ranges Upper threshold Lower threshold Signal shape Nominal frequency of measured signal at AC Nominal power Supply voltage range Galvanic isolation toward supply Functions Time delay at exceeding the threshold Number of change-over contacts Maximum switching current Mechanical life time Electrical life time AC1 Isolation voltage of input/output Connection clamps Wire range fine-stranded/solid Degree of protection / mounting rail Dimensions (mm) W x H x D Operation temperature range Approvals 0,1 / 1 / 10 A 10...100 % of measuring range 50 ... 95 % of upper threshold DC and sinus 45 ... 400 Hz ca. 2 W / 4 VA 20.4 ... 264 V AC/DC Yes Closed circuit or operating circuit principle 0 / 0.1 / 0.,5 / 2 / 10 s 2 (simultaneously switching) 5A 20 x 10 6 0.1 x 10 6 2 kV Pluggable screw clamp 0.2 - 2.5 mm (AWG 24 - 14) IP 20 / TH 35 (EN60715) 22.5 x 96.5 x 114 -25 ... +55 C AE flare CONTROL Monitoring relay flare CONTROL P3-L * 3 phase monitoring relay * Detection for loss of one or more phases * Detection of wrong phase sequence * Closed circuit principle * Width 22.5 mm * 1 change-over contact 6 A flare CONTROL P3-LTN * 3 phase monitoring relay * 3 or 4 wire monitoring * Detection for loss of one or more phases * Detection of wrong phase sequence * Adjustable asymmetry trigger 3 wire * Closed circuit principle * Supports worldwide mains systems (adjustable) * Width 22,5 mm * 1 change-over contact 6 A Type Part No. flare CONTROL P3-L 81.030.0020.0 Technical data Supply voltage range Detection time Number of change-over contacts Maximum switching current Mechanical life time Electrical life time AC1 Connection clamps Wire range fine-stranded/solid Degree of protection / Mounting rail Dimensions (mm) W x H x D Operation temperature range Approvals 200 ... 500 V AC max. 0.1 s 1 6A 10 x 10 6 0.05 x 10 6 Screw clamp 0.14 - 4 mm (AWG 26 - 12) IP 20 / TH 35 (EN60715) 22.5 x 100 x 100 -20 ... +60C AK Type Part No. flare CONTROL P3-LTN 81.030.0021.0 Technical data Supply voltage 3 phase / 3 wire Supply voltage 3 phase / 4 wire Detection range for asymmetry Detection time at asymmetry Number of change-over contacts Maximum switching current Mechanical life time Electrical life time AC1 Connection clamps Wire range fine-stranded/solid Degree of protection / Mounting rail Dimensions (mm) W x H x D Operation temperature range Approvals 380, 400, 415, 480 V AC 220, 230, 240, 277 V AC 2 ...22 % 0.1 ... 30 s 1 6A 10 x 10 6 0.05 x 10 6 Screw clamp 0.14 - 4 mm (AWG 26 - 12) IP 20 / TH 35 (EN60715) 22.5 x 100 x 100 -20 ... +60 C AK 91 92 contacts are green More products which complement your interface applications Contacts are green Wieland Electric is one of the global technology and innovation leaders in the field of pluggable connections for building system technology and industrial automation. Wherever power and signals are distributed, Wieland's motto is: green light for innovative ideas. Because: contacts are green. Wieland Electric offers you suitable products for all applications. Wieland product ranges: n Safety n DIN rail terminal blocks n Industrial plug connectors n Fieldbus components n Distributed automation n Circular connector system n System plug connectors n PCB terminals and connectors 93 safety safety Reliable signal detection sensor PRO Sichere Systemlosungen fur die Automatisierungstechnik Katalog 2012 Sicherheit geht vor. More information is available in the "Safety first" brochure. Order No. 0860.1 94 Universal safety relays safe RELAY safety Safety is a matter of confidence The demands on facilities, machines and vehicles are high these days. Apart from the productivity and efficiency of a machine or vehicle, the focus is also increasingly on safety. Designing modern means of transportation, facilities and machines also requires consideration of the safety of the persons working with these machines or using these means of transportation. Modular safety units samos(R) Compact safety control samos(R)PRO Reliable and innovative solutions are needed that contribute to meeting this important requirement without affecting the productivity and availability of the facility or means of transportation. With its sensor PRO, safe RELAY, samos(R) and samos(R)PRO, Wieland Electric offers superior quality safety components which can contribute substantially to safety in production and operation of modern facilities or machines. 95 fasis & selos Innovative DIN rail terminal blocks DIN rail terminal blocks are the standard connection component in all areas of electrical engineering. Whether in machinery or power supply applications, DIN rail terminal blocks are used for signal and power distribution as well as for the conventional electrical installation of buildings. Wieland Electric DIN rail terminal block product lines from Wieland Electric for worldwide use: Due to their high mechanical strength and contact stability the DIN rail terminal blocks from Wieland are particularly suitable for our customers' requirements. Whether explosion and fire protection, vibration and shock resistance or international approvals for worldwide use - Wieland Electric provides solutions in different connection techniques. fasis DIN Rail Terminal Blocks with Tension Spring Connection A touch of Spring in installation 96 n fasis - DIN rail terminal blocks with spring clamp and push-in connection n selos - DIN rail terminal blocks with screw connection Please find further Information in our catalog DIN Rail terminal blocks Order no: 0500.1 fasis . selos Application Wieland Electric supplies superior quality products for user specific applications. fasis and selos rail terminal block system features: n Reliable functionality n Efficient applications n Customized to your needs Functionality and system Terminal blocks are electrical wire connection systems and can be found wherever electrical energy is generated, transferred and distributed. System components for measuring and control tasks are, e.g.: n Isolating terminals n Fuse blocks n Function blocks Planning and configuration wieplan was developed to provide you with a powerful software tool for configuring terminal block assemblies using Wieland rail terminal blocks. n Configuring terminal block assemblies n Data exchange with CAE systems n Ordering terminal block assemblies n Issuing drawing and parts lists Pre-assembly and installation For customers who want to save time and work on the control cabinet, Wieland Electric offers pre-assembled, fully equipped terminal blocks - even with connected conductors, if desired. n Marking system of all applications in the switch board cabinet n Hand held tools for terminal blocks and accessories n Software tools 97 98 revos For any application - Heavy-duty industrial connectors The revos heavy-duty industrial connectors are categorized according to their housings, contact inserts and connection technology. A wide range standard program, as well as modular components that can be combined, per customer specific requirements, are available. n revos BASIC with 6 to 92-pole contact inserts n revos POWER high-current pluggable connector for currents up to 100 A n revos HD high density multipole pluggable connector with up to 64 poles and up to 10 A n revos FLEX modular hybrid pluggable connector system to equip your connector, as needed, with mixed contact inserts, including signal, pneumatics and fiber optic cable components n revos BASIC EMV for applications where electromagnetic interferences must be shielded from entering or exiting the connector. 99 revos revos BASIC The conventional industrial connector. The die-cast aluminum housing with powder-coated surface provides reliable protection. The contact inserts come in 6-92-pole design. revos BASIC meets the highest demands and is used in the automotive industry, mechanical and system engineering, conveyor systems, and process measuring and control technology. revos POWER The Wieland Electric high current pluggable connector. Contact inserts and multipole adapters accommodate currents exceeding 16 A and are also available with a mix of contact amperages with screw connection. Contact inserts and adaptors are protected inside the revos BASIC housings. revos POWER applications include mechanical and system engineering for small drives, motors, pumps and frequency converters. revos HD revos HD is designed specifically for multi-pole pluggable connectors. The robust housings provide space for contact inserts with 15 to 64 poles and are designed for currents up to 10 A (in compliance with DIN EN 17 5301-801). revos HD proves its strengths in mechanical and system engineering, in escalators, small motors and injection molding machines. revos DD High contact density in a very limited space - this is what revos DD space-saving contact inserts offer. The inserts are compatible with BASIC housing sizes 6/6H-, 10/10H-, 16/16H-, and 24/24H. They are connected with reliable, turned 1.6 mm crimp contacts and a termination range of 0.14 - 2.5 mm2 at a rated voltage of 250 V. 100 revos revos FLEX Do you want a customized industrial pluggable connector for your specific application? No problem, thanks to revos FLEX. With this modular and flexible system, you are free to configure and assemble your pluggable connector according to your needs. The smart solution for any tasks in mechanical and system engineering, in process measuring and control technology and the automotive industry. revos MINI Small but robust. Thanks to its extremely compact contact inserts with 3 to 12 poles, revos MINI can be integrated in applications for mechanical, control systems and control engineering, small motors and lighting engineering. Its zinc die-cast or polyamide pluggable connector housing helps revos MINI to withstand rough environments. revosO In explosion hazardous areas such as mining or the chemical industry, electrical components need to meet specific requirements. The revosO series provides heavy-duty pluggable connectors especially designed for systems where explosion protection is absolutely essential. The BVS (Association of Publicly Certified and Qualified Experts) testing institute approved the use of revosO in zone 1 for intrinsically safe circuits. revos IT In some applications, the data cable feed-through must be protected by a heavy-duty pluggable connector. revos IT is the ideal solution. These connectors facilitate the feeding of pre-assembled cables into a closed, sealed housing with strain relief. D-sub plug-in connections are available with 4 to 100 poles. revos IT protects data transmission to PLCs or to measuring and encoder lines. 101 podis(R) podis(R) & gesis(R) Systems with unique advantages podis(R) - uninterrupted flat cable Application n n n n in conveyor systems in linear-designed facilities in expandable systems in modular-designed systems Advantages podis(R) - uncut flat cable n n n n n 102 No cutting, no stripping Quick and easy connection Secure terminations Just a few components for the entire system Easy-to-add drops wherever needed gesis(R) gesis(R) - plug-in round cable Application n n n n In conveyor facilities For modular-design facilities For star or network structures Where complex cable routing is an issue Advantages gesis(R) - plug-in round cable n n n n n Plug in and go Ideal for modular systems Easy creation of network structures Just a few components for entire system Can be expanded as required 103 Software Software TOOLS Wieland Software perfects your applications Wieland Electric offers specially designed software for its individual products, making them exceptionally easy to use and making configuration and product selection easy. samos(R)PLAN This programming tool for samos(R)PRO supports designers and machine manufacturers in the programming, diagnosis, and documentation of all the safety functions of a machine. revos configurator This software tool facilitates the selection of heavy-duty connectors. SISTEMA library The SISTEMA library contains all safety components from Wieland Electric and, in combination with the SISTEMA software tool provided by the IFA (Institute for Occupational Safety and Health of the German Social Accident Insurance), allows the safety-related parameters of a machine's functions to be calculated according to EN ISO 13849-1. podis PLAN podis PLAN, allows you to design your distributed power bus perfectly and test important electrotechnical parameters. wieplan wiemarc DIN rail terminal blocks: Planning and labeling with a system 104 Support Hotline - one call is all it takes Our Technical Service Department is ready to answer all your questions on the subject of interface. Please call our hotline +49 951 9324-995. Wieland e-Catalog For further technical information and the latest news on interface technology, go to: http://eshop.wieland-electric.com 105 Support Hotline * advice Additional information Technical support Technical Support Automation technology: Building services engineering: Phone: +49 951 9324- . . . Phone: +49 951 9324- . . . -999 * System connectors for building installation gesis CON, gesis RAN, gesis ELECTRONIC -996 * interface: -995 Power supply, industrial Ethernet switches, timer relays, measuring and monitoring relays, coupling relays, analog modules, remote I/O, surge protection, passive interfaces, remote power distribution podis(R) * DIN rail terminal blocks fasis BIT, selos BIT -991 * Safety technology safety e-mail: safety@wieland-electric.com * DIN rail terminal blocks fasis, selos -991 Industrial multipole connectors revos PCB terminals and connectors wiecon, appliance terminals, european terminal strips, housings for electronic components Fax: e-mail: +49 951 9326-991 AT.TS@wieland-electric.com Fax: e-mail: +49 951 9326-996 BIT.TS@wieland-electric.com Technical Support Photovoltaics/solar technology: Phone: +49 951 9324- . . . * Photovoltaics gesis SOLAR Fax: e-mail: -972 +49 951 9326-977 Solar@wieland-electric.com Sales service: * To contact our sales department regarding availability, delivery schedules, and pricing please call Phone: +49 951 9324-990 General information and news: www.wieland-electric.com Visit our eCAT at http://eshop.wieland-electric.com 106 contacts contactsare aregreen green Our subsidiaries ... and the addresses of our representatives worldwide are available at: www.wieland-electric.com USA Wieland Electric Inc. 49 International Road Burgaw, N.C. 28425 Phone +1-910-259 5050 Fax +1-910-259 3691 www.wielandinc.com CANADA Wieland Electric Inc. 2889 Brighton Road Oakville, Ontario L6H 6C9 Phone +1-905-829 8414 Fax +1-905-829 8413 www.wieland-electric.ca GREAT BRITAIN Wieland Electric Ltd. Riverside Business Centre, Walnut Tree Close GB-Guildford/Surrey GU1 4UG Phone +44-1483-531 213 Fax +44-1483-505 029 sales@wieland.co.uk FRANCE Wieland Electric SARL. Le Cerame Hall 6 47, avenue des Genottes CS 48313 95803 Cergy-Pontoise Cedex Phone +33-1-30 32 07 07 Fax +33-1-30 32 07 14 infos@wieland-electric.fr SPAIN Wieland Electric S.L. C/ Maria Auxiliadora 2 bajos E-08017 Barcelona Phone +34-93-252 3820 Fax +34-93-252 3825 ventas@wieland-electric.com ITALY Wieland Electric S.r.l. Via Edison, 209 I-20019 Settimo Milanese Phone +39-02-48 91 63 57 Fax +39-02-48 92 06 85 info@wieland-electric.it POLAND Wieland Electric Sp. Zo.o. w. Antoniego 8 62-080 Swadzim Phone +48-61-2 22 54 00 Fax +48-61-8 40 71 66 office@wieland-electric.pl CHINA Wieland Electric Trading Unit 2703 International Soho City 889 Renmin Rd., Huang Pu District PRC- Shanghai 200010 Phone +86-21-63 555 833 Fax +86-21-63 550 090 info-shanghai@wieland-electric.cn CZECH REPUBLIC (Production) Wieland Electric s.r.o. Nadrani 1557 356 01 Sokolov Phone +420-352 302 011 Fax +420-352 302 027 DENMARK Wieland Electric A/S Valloraekken 26 DK-4600 Koge Phone +45-70-26 66 35 Fax +45-70-26 66 37 sales@wieland-electric.dk F Informational material for ordering and for downloading from our websites Subject to technical modifications! gesis(R), podis(R), samos(R) are registered trademarks of Wieland Electric GmbH 107 Headquarters: Wieland Electric GmbH Brennerstrae 10 - 14 96052 Bamberg, Germany Sales and Marketing Center: Wieland Electric GmbH Benzstrae 9 96052 Bamberg, Germany Phone +49 951 9324-0 Fax +49 951 9324-198 www.wieland-electric.com www.gesis.com info@wieland-electric.com Solutions for the control cabinet * DIN rail terminal blocks - Screw, tension spring or push-in connection technology - Wire cross sections up to 240 mm2 - Numerous special functions - Software solutions interfacing to CAE systems * Safety - Safe signal acquisition - Safety switching devices - Modular safety modules - Compact safety controllers - Applicative consultancy and training * Network engineering and fieldbus systems - Remote maintenance via VPN industrial router and VPN service portal - Industrial Ethernet switches - PLC and I/O systems, standard and increased environmental conditions * Interface - Power supply units - Overvoltage protection - Coupling relays, semiconductor switches - Timer relays, measuring and monitoring relays - Analog coupling and converter modules - Passive interfaces Solutions for field applications * Decentralized installation and automation technology - Electrical installation for wind tower - Fieldbus interfaces and motor starters * Connectors for industrial applications - Rectangular and round connectors - Aluminum or plastic housings - Degree of protection up to IP 68 - Current-carrying capacity up to 100 A - Connectors for hazardous areas - Modular, application-specific technology PC board terminals and connectors - Screw or spring clamp connection technology - Spacings: 3.5 mm to 10.16 mm - Reflow or wave soldering process interface interface Industrial technology Building and installation technology * Building installation systems - Main power supply connectors IP 20/IP 65 ... IP 68 - Bus connectors - Low-voltage connectors - Power distribution system with flat cables - Distribution systems - Bus systems in KNX, LON and radio technology - DIN rail terminal blocks for electrical installations - Overvoltage protection interface Solutions for the Control Cabinet Catalog 2013 0800.1 C 11/12