CXA20 SERIES
Single and dual output
[ 2 YEAR WARRANTY ]
• 4:1 input voltage range
• No minimum load on singles
• 6A on 3.3V output (@ 48Vin) at 50˚C in still air
• Wide operating temperature with overtemperature
protection
• ±10% output voltage trim
• Remote On/Off control
• Overvoltage protection
• Pin compatible with NFC15 and NFC20 series
The CXA20 is a new 20W addition to the CXA family of open-frame, isolated, DC/DC
converters. The five model series features a 4:1 input voltage range of 18 to 75VDC,
making it suitable for a wide variety of communications and distributed power
applications. With its 2.0 x 1.6 inch industry standard footprint, the CXA20 provides
an easy upgrade option for new and existing Artesyn customers seeking a high-
performance, cost-effective power supply. The CXA20 is available in output voltages
of 3.3V, 5V, 12V, ±5V and ±12V. The 3.3V version delivering up to 6A is fully rated to
20W. Typical efficiency for the CXA20 is 83 percent. The CXA20 offers remote on/off,
as well as overvoltage, overtemperature and short circuit protection features.
SPECIFICATION
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
PAGE 118
OUTPUT SPECIFICATIONS
Voltage accuracy ±1.0%
Line regulation Singles/dual positives ±0.1%
(LL to HL) Dual negatives ±0.1%
Load regulation Full load to minimum load
(not incl. cross reg.) S3V3 ±0.2%
Singles/dual positives ±0.1%
Dual negatives ±0.1%
Minimum load Singles None
Duals (for imbalanced loads) 10%
Ripple and noise S3V3, S05, D05 75mV pk-pk max.
20MHz bandwidth S12, D12 100mV pk-pk max.
All models 20mV rms max.
Temperature coefficient ±0.02%/°C
Overvoltage protection See Application Note 107
Short circuit protection Hiccup Continuous
Short <20mautomatic recovery
Transient response 25% load step ±2.0% max. dev.,
300µs recovery to
within total error band
Load cross regulation 10% load to full load, ±7.0%
(See Note 1) either output
INPUT SPECIFICATIONS
Input voltage range 48Vin nominal 18 to 75VDC
Input fuse HRC recommended 2.0A
Max. input rise 48V ETS300-132 5V/ms
and fall time
UVLO turn ON voltage (See Note 4) 92%
UVLO turn OFF voltage (See Note 4) 86%
Remote ON/OFF
Logic compatibility CMOS/TTL/Open Collector
ON Open circuit or >2VDC
OFF <1.2VDC
NEW
Product
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS
ETS 300 386-1 table 5
Conducted emissions EN55022, ext. cap. (Note 5) Level A
EN55022, external filter, Level B
VDE0878, 48V models
Radiated emissions EN55022-B See App. Note 107
Immunity:
ESD air EN61000-4-2 8kV (NP), 15kV (RP)
ESD contact EN61000-4-2 6kV (NP), 8kV (RP)
EFT DC power EN61000-4-4 2kV (NP), 4kV (LFS)
EFT signal EN61000-4-4 1kV (NP), 2kV (LFS)
Radiated field enclosure EN61000-4-3 10V/m (NP)
Surges indoor signal EN61000-4-5 500V (RP)
Conducted (DC power) EN61000-4-6 10V (NP)
Conducted (signal) EN61000-4-6 10V (NP)
Input transients ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency See table
Overtemp. shutdown 120˚C
Isolation voltage Input/output test voltage 1500VDC
Switching frequency Fixed 400kHz
Approvals and standards
EN60950
(See Notes 6,7,8) UL1950 File No. E136005
Material flammability UL94V-0
Weight 26g (0.92 oz)
MTBF MIL-HDBK-217F 400,000 hours
(Representative model Parts stress method
48S05 @ 48Vin) Ground Benign @ 25°C
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient -40°C to +60°C,
temperature (See Note 9)
Non-operating -55°C to +125°C
ETS 300 019-2-3 Classes T3.1, 3.2, 3.3, 3.5
Air temperature Low: IEC 68-2-1 -40°C
High: IEC 68-2-2 +60°C
Change: IEC 68-2-14 -40°C to +60°C
Relative humidity IEC 68-2-56 10% to 100% RH
IEC 68-2-30 Condensation
INPUT OUTPUT OVERVOLTAGE OUTPUT TYPICAL MODEL
VOLTAGE VOLTAGE PROTECTION (2,3) CURRENT (MAX.) EFFICIENCY NUMBER(10)
18-75VDC 3.3V 3.7V 6.0A 80% CXA20-48S3V3
18-75VDC 5.0V 6.67V 4.0A 83% CXA20-48S05
18-75VDC 12V 14.25V 1.66A 83% CXA20-48S12
18-75VDC ±5V 6.67V 2.0A ea. 84% CXA20-48D05
18-75VDC ±12V 14.25V 0.83A ea. 84% CXA20-48D12
20 Watt
DC/DC converters
DC/DC CONVERTERS |
20W DC/DC
http://www.artesyn.com
Notes
1 Negative output voltage deviation when either load is changed.
2 For TVS/Zener specifications please see Application Note 107.
3 On dual output models, OVP protection is on positive outputs only.
4 With respect to minimum input voltage.
5 With one external 4µF capacitor across the input.
6 Unit provides basic insulation up to the 75VDC maximum input voltage.
7 Maximum continuous output power not to exceed 20 Watts.
8 User must provide 2A HRC (recommended) in line fuse in order to comply
with safety approvals.
9 Download Application Note 107 and the full data sheet from our website.
10 Active high remote on/off is available. Standard product is active low.
Designate with the suffix 'H', e.g. CXA20-48S05H.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
STAND-OFFS
4 PLACES Ø0.040 ±0.004
(Ø1.02 ±0.1)
2.00 ±0.02
(50.80 ±0.5)
1.80
(45.72)
1
ALL DIMENSIONS IN INCHES (mm)
General tolerance ±0.010 (±0.25)
unless otherwise specified
2
4
5
6
7
8
0.02 ±0.004
(0.50 ±0.1)
1.60 ±0.02
(40.64 ±0.5)
0.70
(17.78) 0.20
(5.08)
0.10
(2.54)
0.30
(7.62) 0.70
(17.78)
0.50
(12.70)
0.60
(15.24)
0.14 ±0.02
(3.60 ±0.5)
0.413
(10.50)
MAX. OPEN
FRAME
HEIGHT
BOTTOM
VIEW
TRIM
DOWN
+ Output
TRIM
UP
Trim
- Output
PIN CONNECTIONS
PIN NUMBER SINGLE OUTPUT DUAL OUTPUT
1 + Input + Input
2 – Input - Input
3 No Pin No Pin
4 Remote On/Off Remote On/Off
5 No Pin + Output
6 + Output Common
7 - Output - Output
8 Trim Trim
Data Sheet © Artesyn Technologies
®
2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Derating Curve Output Current vs Temperature S3V3
Natural Convection (<0.1m/s airflow)
-40˚C
0
20
40
60
80
100
Ambient Temperature
Rated Output Current
-20˚C0˚20˚40˚60˚80˚100˚
75%
PAGE 119
Please consult our website for the following items: Application Note Full Data Sheet
MAX. TEMPERATURES FOR FULL RATED OUTPUT CURRENT
MODEL FULL Vin RANGE Vin <60VDC
48S3V3 50˚C 50˚C
48S05 55˚C 60˚C
48S12 50˚C 55˚C
48D05 55˚C 60˚C
48D12 50˚C 60˚C
EXTERNAL OUTPUT TRIMMING
All models can be externally trimmed by ±10% using either
method shown below. See Application Note 107 for details. 5
new product
DS_CXA20_20000101.PDF