Dimensions and weights
Depth 105 mm Depth (inches) 4.134 inch
Height 135 mm Height (inches) 5.315 inch
Net weight 765 g Width 53.6 mm
Width (inches) 2.11 inch
Temperatures
Storage temperature -40 °C...85 °C Operating temperature 0 °C...60 °C
Humidity 5 to 95 % (non-
condensing)
Environmental Product Compliance
REACH SVHC Lead 7439-92-1
EMC conformity and approvals
EMC standards EN 55032, EN 55024,
CISPR 32, FCC Part
15 Subpart B Class A,
IEC 61000-4-2 ESD:
Contact: 6 kV; Air: 8 kV,
IEC 61000-4-3 RS: 80
MHz bis 1 Ghz: 3 V/
m, IEC 61000-4-4 EFT:
Power: 2 kV; Signal: 2
kV, IEC 61000-4-5 Surge:
Power: 1 kV; Signal: 1 kV,
IEC 61000-4-6 CS: 3 V/
m, IEC 61000-4-8, IEC
61000-4-11
Explosive risk zone
UL/cUL, Class I, Division
2, Groups A, B, C and D,
ATEX Zone 2 Ex nA nC IIC
T4 Gc
Free fall According to IEC
60068-2-32
Safety standard UL508, UL 60950-1, EN
60950-1
Ship use
DNV-GL
Shock according to IEC
60068-2-27
Vibration according to IEC
60068-2-6
Environmental conditions
Humidity 5 to 95 % (non-
condensing)
Operating temperature, max.
60 °C
Operating temperature, min. 0 °C Storage temperature, max. 85 °C
Storage temperature, min. -40 °C
Fibre optic transceiver characteristics
Transmission rate 100 Mbps
Transceiver type Multimode
Connector type SC-Duplex
Transmission distance, typ. 5 km