PowerLogic PM5000 series Basic multi-function meters Technical datasheet Basic multi-function metering PM5000 Series Functions and characteristics PB111776 PowerLogicTM PM5100, PM5300 and PM5500 series The PowerLogicTM PM5000 power meter is the ideal fit for cost management applications. It provides the measurement capabilities needed to allocate energy usage, perform tenant metering and sub-billing, pin-point energy savings, optimize equipment efficiency and utilization, and perform a high level assessment of the power quality of the electrical network. In a single 96 x 96 mm unit, with a graphical display, all three phases, neutral and ground can be monitored simultaneously. The bright, anti-glare display features large characters and powerful backlighting for easy reading even in extreme lighting conditions and viewing angles. Easy to understand menus, text in 8 selectable languages, icons and graphics create a friendly environment to learn about your electrical network. Highly accurate devices with global billing certifications. Applications PowerLogicTM PM5000 Series meter Commercial reference numbers PM5100 METSEPM5100 PM5110 METSEPM5110 PM5111 METSEPM5111 PM5310 METSEPM5310 PM5320 METSEPM5320 PM5330 METSEPM5330 PM5331 METSEPM5331 PM5340 METSEPM5340 PM5341 METSEPM5341 PM5560 METSEPM5560 PM5561 METSEPM5561 PM5563 METSEPM5563 Cost management: Cost saving opportunities becomes clear once you understand how and when your facility uses electricity. The PowerLogicTM PM5000 series meters are ideal for: * Sub billing / tenant metering: allows a landlord, property management firm, condominium association, homeowners association, or other multi-tenant property to bill tenants for individual measured utility (electricity) usage. MID approved meters for billing applications across Europe. * Cost allocation: allocate energy costs between different departments (HVAC, indoor and outdoor lighting, refrigeration, etc), different parts of an industrial process or different cost centres. Cost allocation systems can help you save money by making changes to your operation, better maintaining your equipment, taking advantage of pricing fluctuations, and managing your demand. Network management: Improving reliability of the electrical network is key for success in any business. Monitoring values such as voltage levels, harmonic distortion and voltage unbalance will help you to ensure proper operation and maintenance of your electrical network and equipment. PowerLogicTM PM5000 series meters are the perfect tool for: * Basic Power Quality monitoring: power quality phenomena can cause undesirable effects such as heating in transformers, capacitors, motors, generators and misoperation of electronic equipment and protection devices. * Min/ Max monitoring (with timestamp): understanding when electrical parameters, such as voltage, current and power demand, reach maximum and minimum values will give you the insight to correctly maintain your electrical network and assure equipment will not be damaged. * Alarming: alarms help you to be aware of any abnormal behavior on the electrical network in the moment it happens. * WAGES monitoring: take advantage of the input metering on PM5000 meters to integrate measurements from 3rd party devices such as water, air, gas, electricity or steam, meters. Main characteristics Easy to install Mounts using two clips, in standard cut out for DIN 96 x 96mm, no tools required. Compact meter with 72mm (77mm for PM5500) depth connectable up to 690 VL-L without voltage transformers for installations compliant with category III. Easy to operate Intuitive navigation with self-guided, language selectable menus, six lines, four concurrent values. Two LEDs on the meter face help the user confirm normal operation with a green LED - heartbeat/communications indicator, and the amber LED - customizable either for alarms or energy pulse outputs. Easy circuit breaker monitoring and control The PM5300 provides two relay outputs (high performance Form A type) with capability to command most of the circuit breaker coils directly. For Digital Inputs, monitored switches can be wired directly to the meter without external power supply. PM5500 series have 4 status inputs (digital) and 2 digital output (solid state) to use for WAGES monitoring, control and alarm annunciation. Accurate energy measurement for precise cost allocation: 2 PM5100 PM5300 PM5500 IEC 62053-22 (Active Energy) Class 0.5S Class 0.5S Class 0.2S IEC 62053-24 (Reactive Energy) Class 2 Class 2 Class 1 2013 Basic multi-function metering PM5000 Series Functions and characteristics (cont.) PB111768 Direct metering of neutral current The PM5500 has a fourth CT for measuring neutral current. In demanding IT applications, where loads are non-linear (i.e. switching power supplies on computers/ servers), measuring neutral current is essential to avoid overload and resulting outage. In addition, the PM5500 provides a calculated ground current value, not available in meters with 3 CTs. Power Quality analysis The PM5000 offers Total Harmonic Distortion (THD/thd), Total Demand Distortion (TDD) measurements and individual harmonics (odd) magnitudes and angles for voltage and current: Individual Harmonics PowerLogicTM PM5500 meter PM5100 PM5300 PM5500 magnitudes up to 15th magnitudes up to 31st magnitudes & angles up to 63rd These types of power quality parameters help to identify the source of harmonics that can harm transformers, capacitors, generators, motors and electronic equipment. PB111770 Load management Peak demands with time stamping are provided. Predicted demand values can be used in combination with alarms for basic load shedding applications. Alarming with time stamping A different combination of set point driven alarms and digital alarms with 1s time stamping are available in the PM5000 family: PM5100 PM5300 PM5500 Set point driven alarms 29 29 29 Unary 4 4 4 Digital - 2 4 Boolean / Logic - - 10 Custom defined - - 5 PowerLogicTM PM5300 meter PB111768 Alarms can be visualized as Active (the ones that have picked up and did not drop out yet) or Historical (the ones that happened in the past). Alarms can be programmed and combined to trigger digital outputs and mechanical relays (PM5300). The PM5000 series keeps an alarm log with the active and historical alarms with date and time stamping. Load timer A load timer can be set to count load running hours based on a minimum current withdraw, adjustable to monitor and advise maintenance requirements on the load. PowerLogicTM PM5100 meter High Performance and accuracy IEC 61557-12 Performance measuring and monitoring devices (PMD) Defines the performance expectation based on classes. It defines the allowable error in the class for real and reactive power and energy, frequency, current, voltage, power factor, voltage unbalance, voltage and current harmonics (odds), voltage THD, current THD, as well as ratings for temperature, relative humidity, altitude, startup current and safety. It makes compliant meters readings comparable - they will measure the same values when connected to the same load. Meets IEC 61557-12* PMD/[SD|SS]/K70/0.5 for PM5100 and PM5300 Meets IEC 61557-12* PMD/[SD|SS]/K70/0.2 for PM5500 Certified according to MID Directive, Annex "B" + Annex "D" for legal metrology relevant to active electrical energy meters (see Annex MI-003 of MID). Can be used for fiscal (legal) metrology. MID Legal billing compliance MID compliance is compulsory for billing applications across Europe. In addition to billing applications, for facility managers responsible for energy cost MID means same level of quality as a billing meter. MID ready compliance, EN50470-1/3 - Class C *Pending approval. 2013 3 Basic multi-function metering PM5000 Series Functions and characteristics (cont.) General PM5100 PM5300 Use on LV and MV systems b Basic metering with THD and min/max readings b Instantaneous rms values PM5500 Current per phase, neutral and ground (PM5500) b Voltage Total, per phase L-L and L-N b Frequency Real, reactive, and apparent power Total and per phase b Signed, Four Quadrant True Power Factor Total and per phase Signed, Four Quadrant Displacement PF Total and per phase Signed, Four Quadrant b % Unbalanced I, VL-N, VL-L Direct monitoring of neutral current b Energy values* Accumulated Active, Reactive and Apparent Energy Received/Delivered; Net and absolute; Time Counters Demand values* Current average Present, Last, Predicted, Peak, and Peak Date Time Active power Present, Last, Predicted, Peak, and Peak Date Time Reactive power Present, Last, Predicted, Peak, and Peak Date Time Apparent power Present, Last, Predicted, Peak, and Peak Date Time Peak demand with time stamping D/T for current and powers b Demand calculation Sliding, fixed and rolling block, thermal methods b Synchronization of the measurement window to input, communication command or internal clock b Settable Demand intervals b b Demand calculation for Pulse input (WAGES) Other measurements* I/O timer b Operating timer b Load timer b Alarm counters and alarm logs b Power quality measurements I,VLN, VLL THD, thd (Total Harmonic Distortion) I, VLN, VLL per phase b TDD (Total Demand Distortion) Individual harmonics (odds) 15th 31st 63rd b Neutral Current metering with ground current calculation Data recording b Min/max of instantaneous values, plus phase identification* b Alarms with 1s timestamping* Data logging Memory capacity Min/max log b Maintenance, alarm and event logs 2 fixed parameters kWh and kVAh with configurable interval and duration (e.g. 2 parameters for 60 days at 15 minutes interval) 256 kB Up to 14 selectable parameters with configurable interval and duration (e.g. 6 parameters for 90 days at 15 minutes interval) b b b b 1.1 MB b Customizable data logs Inputs / Outputs / Mechanical Relays 2 (SI1, SI2) Digital inputs Digital outputs 1 (kWh only) 2 (configurable) 2 Form A Relay outputs Timestamp resolution in seconds 1 Whetting voltage b *Stored in non-volatile memory 4 2013 4 (SI1, SI2, SI3, SI4) with WAGES support Basic multi-function metering PM5000 Series Functions and characteristics (cont.) Electrical characteristics* PM5100 Type of measurement: True rms on three-phase (3P, 3P + N), zero blind Measurement IEC 61557-12 accuracy Active Energy PMD/[SD|SS]/K70/0.2 Class 0.2S as per IEC 62053-22 Reactive Energy Class 2S as per IEC62053-24 Class 1S as per IEC62053-24 Active Energy Reactive Energy 0.5% 2% Class 0.5 as per IEC 61557-12 0.2% 1% Class 0.2 as per IEC 61557-12 Class 0.5 as per IEC 61557-12 Current, Phase Class 0.5 as per IEC 61557-12 0.15% Voltage, L-N Class 0.5 as per IEC 61557-12 0.1% Frequency 0.05% MID Directive EN50470-1, EN50470-3 Input-voltage (up to 1.0 MV AC max, with voltage transformer) Nominal Measured Voltage range Input-current I nom Annex B and Annex D (Optional model references) Class C 20 V L-N / 35 V L-L to 400 V L-N /690 V L-L absolute range 35 V L-L to 760 V L-L 20 V L-N / 20 V L-L to 400 V L-N /690 V L-L absolute range 20 V L-L to 828 V L-L 5M Impedance 50 or 60 Hz 5% F nom Starting current: 5mA Operating range: 50mA to 8.5A Starting current: 5m A Operating range: 50 mA to 10 A Continuous 20A, 10s/hr 50A, 1s/hr 500A Withstand Impedance F nom Burden Operating range < 0.3 m 50 or 60 Hz 5% 50 or 60 Hz 10% <0.026VA at 8.5A 100 - 277 V AC L-N / 415 V L-L +/-10% CAT III 300V class per IEC 61010 Burden <5 W,11 VA at 415V L-L Frequency Ride-through time 100-480 V AC 10% CAT III 600V class per IEC 61010 <5W/16.0 VA at 480 V AC 45 to 65 Hz 80 mS typical at 120V AC and maximum burden. 100 mS typical at 230 V AC and maximum burden 100 mS typical at 415 V AC and maximum burden Operating range 35 ms typical at 120 V L-N and maximum burden 129 ms typical at 230 V L-N and maximum burden 125-250 V DC 20% Burden <4 W at 250 V DC Ride-through time Relay 50 or 60 Hz 10% 1 A or 5 A Measured Amps with over range and Crest Factor Outputs PM5500 128 samples per cycle PMD/[SD|SS]/K70/0.5 Apparent Power DC control power PM5300 Class 0.5S as per IEC 62053-22 Active Power AC control power 64 samples per cycle typical 3.1W at 125 V DC, max. 5W 50 mS typical at 125 V DC and maximum burden Max output frequency 0.5 Hz maximum (1 second ON / 1 second OFF - minimum times) 250 V AC at 8.0 Amps, 25 k cycles, resistive 30 V DC at 2.0 Amps, 75 k cycles, resistive 30 V DC at 5.0 Amps, 12.5 k cycles, resistive 2.5 kV rms Switching current Isolation Digital outputs 2 1 2 Max load voltage 40 V DC 30 V AC / 60 V DC Max load current 20 mA 125 mA On Resistance 50 max 8 Meter constant from 1 to 9,999,999 pulses per kWh Pulse width for Digital Output Pulse frequency for Digital Output Leakage current 50% duty cycle 25 Hz max. Isolation Optical outputs Pulse width (LED) Pulse frequency Meter constant 0.03 micro Amps 1 micro Amps 5 kV rms 2.5 kV rms 200 ms 50 Hz. max. from 1 to 9,999,999 pulses per kWh 2013 2.5 kHz. max 5 Basic multi-function metering PM5000 Series Functions and characteristics (cont.) Electrical characteristics* (cont'd) Status Inputs PM5100 ON Voltage PM5300 PM5500 18.5 to 36 V DC 30 V AC / 60 V DC max OFF Voltage 0 to 4 V DC Input Resistance Maximum Frequency Response Time Opto Isolation Whetting output 110 k 100 k 2 Hz (T ON min = T OFF min = 250 ms) 20 ms 25 Hz (T ON min = T OFF min = 20 ms) 10 ms 5 kV rms 2.5 kV rms 24 V DC/ 8mA max Input Burden 2mA @24V DC 2 mA @ 24 V AC/DC 430 g 450 g Mechanical characteristics Product weight 380 g IP degree of protection (IEC 60529) Dimensions W x H x D [protrusion from cabinet] ** IP52 front display, IP30 meter body 96 x 96 x 72mm (77mm for PM5500) (depth of meter from housing mounting flange) [13mm] Mounting position ** Panel thickness Vertical 6 mm maximum Environmental characteristics Operating temperature Meter -25 C to 70 C Display (Display functions to -25 with reduced performance) -25 C to +70 C Storage temp. -40 C to +85 C Humidity range 5 to 95 % RH at 50 C (non-condensing) Polution degree 2 Altitude 2000 m CAT III / 3000 m CAT II Electromagnetic compatibility*** Harmonic current emissions Flicker emissions IEC 61000-3-2 IEC 61000-3-3 Electrostatic discharge IEC 61000-4-2 Immunity to radiated fields IEC 61000-4-3 Immunity to fast transients IEC 61000-4-4 Immunity to surge IEC 61000-4-5 Conducted immunity 150kHz to 80MHz IEC 61000-4-6 Immunity to magnetic fields IEC 61000-4-8 Immunity to voltage dips IEC 61000-4-11 Radiated emissions FCC part 15, EN 55022 Class B Conducted emissions FCC part 15, EN 55022 Class B *Electrical Characteristics still under verification at time of printing of the catalogue, may be subject to change. ** PM5563 is DIN mounted *** Tests are conducted as per IEC 61557-12 (IEC 61326-1), 62052-11 and EN50470 6 2013 3000 m max. CAT III Basic multi-function metering PM5000 Series Functions and characteristics (cont.) Safety PM5100 Europe PM5300 PM5500 CE, as per IEC 61010-1 Ed. 3, IEC 62052-11 & IEC61557-12 U.S. and Canada cULus as per UL61010-1 (3rd Edition) Measurement category (Voltage and Current inputs) CAT III up to 400 V L-N / 690 V L-L Dielectric As per IEC/UL 61010-1 Ed. 3 Protective Class II, Double insulated for user accessible parts Communication RS 485 port Modbus RTU, Modbus ASCII (7 or 8 bit), JBUS 2-Wire, 9600,19200 or 38400 baud, Parity - Even, Odd, None, 1 stop bit if parity Odd or Even, 2 stop bits if None; (Optional in PM51x and PM53x) Ethernet port: 10/100 Mbps; Modbus TCP/IP 1 Optional Firmware and language file update 2 (for daisy chain only, one IP address) Meter firmware update via the communication ports Isolation 2.5 kVrms, double insulated Human machine interface Display type Monochrome Graphics LCD Resolution 128 x 128 Backlight White LED Viewable area (W x H) 67 x 62.5 mm Keypad 4-button Indicator Heartbeat / Comm activity Green LED Energy pulse output / Active alarm indication (configurable) Optical, amber LED Wavelength 590 to 635 nm PE86288 Maximum pulse rate Features and Options Installation Fast installation, panel mount with integrated display Fast installation, DIN rail mountable 2.5 kHz PM5100 PM5100 PM5110 b b PM5310 b PM5300 PM5320 PM5330 b b PM5340 b PM5500 PM5560 PM5563 b - - - - - - - - b CI 0.5S CI 0.5S CI 0.5S CI 0.5S CI 0.5S CI 0.5S CI 0.2S CI 0.2S b b b b b b b b 3-phase voltage, current, power, demand, energy, frequency, power factor b b b b b b b b Multi-tariff - - 4 4 4 4 8 8 Accuracy Display Backlit LCD, multilingual, bar graphs, 6 lines, 4 concurrent values Power and energy metering Power quality analysis THD, thd, TDD Harmonics, individual (odd) up to b b b b b b b b 15th 15th 31st 31st 31st 31st 63rd 63rd 1DO 1DO 2DI/2DO 2DI/2DO 0 0 2DI/2DO 2 4DI/2DO 0 2DI/2DO 2 4DI/2DO 0 0 0 52 I/Os and relays I/Os Relays Alarms and control Alarms 33 33 35 35 35 35 52 Set point response time, seconds 1 1 1 1 1 1 1 1 Single and multi-condition alarms - - b b b b b b Boolean alarm logic - - - - - - b b - - 1 1 1 - 1 1 - - 1 - - 1 2** 2** PM5331 PM5341 PM5561 Communications Serial ports with modbus protocol Ethernet port with Modbus TCP protocol MID ready compliance, EN50470-1/3, Annex B and Annex D Class C PM5111 ** 2 Ethernet ports for daisy chain, one IP address. 2013 7 Basic multi-function metering PM5000 Series Dimensions and connection PB111276 PM5000 Series meter flush mounting* PB111279 PM5000 Series meter dimensions PB111278 PB111277 PM5100 / PM5300 PM5500 PM5000 meter parts A Menu selection buttons B LED indicators C Navigation or menu selections D Maintenance and alarm notification area PM5500 meter parts E Voltage inputs F RS-485 comms G Digital inputs H Current inputs I Digital outputs J Ethernet ports K Control power PM5100 / PM5300 meter parts E Relay output (PM5300 only) F Voltage inputs G Control power H Current inputs I Status inputs/digital outputs J Communications port: Ethernet (PM5300 only) or RS-485) ** PM5563 is DIN mounted Please see the Installation Guide for accurate and complete information on the installation of this product. 8 2013 PM5500 As standards, specifications and designs develop from time to time, please ask for confirmation of the information given in this document. RCS Nanterre 954 503 439 Capital social 896 313 776 www.schneider-electric.com Design: Schneider Electric Photos: Schneider Electric This document has been printed on recycled paper 10-31-1247 PLSED310052EN 07-2013 ART 059363 / (c) 2013 - Schneider Electric - All rights reserved Schneider Electric Industries SAS 35, Rue Joseph Monier, CS 30323 F - 92506 Rueil Malmaison Cedex