7/30/2000
PCB-MOUNT UNIVERSAL INPUT AC-DC POWER SUPPLIES
ENCAPSULATED MODULES 5-WATTS SINGLE & DUAL OUTPUT
APS05AM-S & APS05AM-D SERIES
Advanced Power Solutions
FEATURES:
! ON-BOARD AC/DC MODULAR
POWER SUPPLIES
! WIDE INPUT VOLTAGE FOR
THE WORLD WIDE USE
! COMPACT IN SIZE
! DESIGNED TO MEET UNIVERSAL
SAFETY STANDARDS
! EMI MEET CISPR PUB.22 / FCC CLASS B
! CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac. (Or 110-340Vdc)
Input Frequency: 47-63 Hz. or DC
Input Current: 0.15A @115Vac./0.07A @230Vac
Inrush Current: 32.5A peak @ 230Vac
Input Fuse: Use external fuse. 1.0A/250Vac for the
primary fuse is suggested
Dielectric Withstand: Meet IEC950
3,000Vac-Output/Input
1,500Vac-Input/GND
500Vac-Output/GND
EMI: Meet CISPR PUB. 22 / FCC Class B
Hold-up t ime: 20 mS @115Vac, 80mS @230Vac
Earth Leakage: Less than 3.5mA @230Vac
OUTPUT SPECIFICATION
Output Voltage : See Ratings Chart.
Output Current: See Ratings Chart
Output Wattage: Typ. 5Watts.
Output Indicator: LED
Line Regulation: APS05AM-S ±0.1% typ.
APS05AM-D ±0.5% typ.
Load Regulation: APS05AM-S ±1.0% typ.
APS05AM-D ±2.0% typ.
Noise & ripple: Typ. 1.0% peak to peak
OVP: Built-in on main output
Adjustability: From -10% of main output till OVP
Short Circuit Protection: Power fold back,
self-recovering
Overload Protection: About 130% of overrange
foldback type
GENERAL SPECIFICATION
Efficiency: Typ. 65% - 67%
Switching Frequency: 75KHz
Circuit Topology: Fixed Frequency Flyback circuit
Transient Re sponse: Output voltage returns in
less than 3mS following a
50% load change
Case: Impact resistant thermo-plastic enclosure
Weight: 107.0g (3.77 Oz)
Power Density: 1.61 Watts./ Cubic inch
Safety Standard: EN60950/ UL1950 Class I
Operating Temperature: -25 to +71°C range
-10°C to +50°C without derating. Derating linearly
2.5%/°C from +50°C @F-L to +71°C @ H-L
(Refer to Derating Chart)
Storage Temperature: -40°C to +85°C
Temperature Coefficient: 0.02% /°C
Humidity: Up to 95%RH, Non-conde nsi ng
Cooling: Convection cooling for +50°C @ full load
At least 100LFM moving air is recommended
for full load > +50°C in a confined area
Commercial Grade only
Note: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load Regulation measured from Full-Load(F-L) to Half-Load (H-L) at nominal input and others loaded at half load.