SD101AWS - SD101CWS SURFACE MOUNT SCHOTTKY BARRIER DIODE Features Mechanical Data * * * * * * * * * Low Forward Voltage Drop Guard Ring Construction for Transient Protection Negligible Reverse Recovery Time Low Capacitance Ultra-small Surface Mount Package Lead Free/RoHS Compliant Version (Note 1) "Green" Device (Note 2) * * * * Case: SOD323 Case Material: Molded Plastic. UL Flammability Classification Rating 94V-0 Moisture Sensitivity: Level 1 per J-STD-020 Polarity: Cathode Band Leads: Matte Tin Finish annealed over Alloy 42 leadframe (Lead Free Plating). Solderable per MIL-STD-202, Method 208 Weight: 0.004 grams (approximate) Top View Ordering Information (Note 3) Part Number SD101AWS-7-F SD101BWS-7-F SD101CWS-7-F Notes: Case SOD323 SOD323 SOD323 Packaging 3000/Tape & Reel 3000/Tape & Reel 3000/Tape & Reel 1. No purposefully added lead. 2. Diodes Inc.'s "Green" policy can be found on our website at http://www.diodes.com/ 3. For packaging details, go to our website at http://www.diodes.com. Marking Information XX SD101AWS - SD101CWS Document number: DS30078 Rev. 12 - 2 xx = Product Type Marking Code S1 or SK = SD101AWS S2 or SK = SD101BWS S3 or SC or SK = SD101CWS 1 of 4 www.diodes.com January 2012 (c) Diodes Incorporated SD101AWS - SD101CWS Maximum Ratings @TA = 25C unless otherwise specified Characteristic Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage Symbol VRRM VRWM VR VR(RMS) IFM RMS Reverse Voltage Forward Continuous Current (Note 4) Non-Repetitive Peak Forward Surge Current SD101AWS SD101BWS SD101CWS Unit 60 50 40 V 42 28 V mA IFSM 35 15 50 2.0 Symbol PD RJA TJ, TSTG Value 200 625 -65 to +125 @ t 1.0s @ t = 10s mA Thermal Characteristics Characteristic Power Dissipation (Note 4) Thermal Resistance, Junction to Ambient Air (Note 4) Operating and Storage Temperature Range Electrical Characteristics @TA = 25C unless otherwise specified Characteristic Reverse Breakdown Voltage (Note 5) Forward Voltage Drop Peak Reverse Current (Note 5) Total Capacitance Reverse Recovery Time Notes: Unit mW C/W C Symbol SD101AWS SD101BWS SD101CWS SD101AWS SD101BWS SD101CWS SD101AWS SD101BWS SD101CWS SD101AWS SD101BWS SD101CWS SD101AWS SD101BWS SD101CWS V(BR)R VFM IRM CT trr Min 60 50 40 Typ Max 0.41 0.40 0.39 1.00 0.95 0.90 200 200 200 2.0 2.1 2.2 Unit 1.0 ns V V nA pF Test Conditions IR = 10A IR = 10A IR = 10A IF = 1.0mA IF = 1.0mA IF = 1.0mA IF = 15mA IF = 15mA IF = 15mA VR = 50V VR = 40V VR = 30V VR = 0V, f = 1.0MHz VR = 0V, f = 1.0MHz VR = 0V, f = 1.0MHz IF = IR = 5.0mA, Irr = 0.1 x IR, RL = 100 4. Part mounted on FR-4 PC board with recommended pad layout, which can be found on our website at http://www.diodes.com. 5. Short duration pulse test used to minimize self-heating effect. SD101AWS - SD101CWS Document number: DS30078 Rev. 12 - 2 2 of 4 www.diodes.com January 2012 (c) Diodes Incorporated 100 IR, INSTANTANEOUS REVERSE CURRENT (nA) IF, INSTANTANEOUS FORWARD CURRENT (mA) SD101AWS - SD101CWS T A = 125C TA = 75C TA = 25C 10 1.0 TA = 0C 0.1 T A = -40C 0 10,000 1,000 100 10 1 0.1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 VF, INSTANTANEOUS FORWARD VOLTAGE (V) Fig. 1 Typical Forward Characteristics 0 1.8 10 40 20 30 50 60 VR, INSTANTANEOUS REVERSE VOLTAGE (V) Fig. 2 Typical Reverse Characteristics 250 1.6 PD, POWER DISSIPATION (mW) CT, TOTAL CAPACITANCE (pF) f = 1.0MHz 1.4 1.2 1.0 0.8 0.6 0.4 200 150 100 50 0.2 0 0 0 5 10 20 15 25 35 30 0 40 40 80 120 160 200 TA, AMBIENT TEMPERATURE (C) Fig. 4 Power Derating Curve VR, DC REVERSE VOLTAGE (V) Fig. 3 Total Capacitance vs. Reverse Voltage Package Outline Dimensions C H A B M K L SD101AWS - SD101CWS Document number: DS30078 Rev. 12 - 2 J 3 of 4 www.diodes.com SOD323 Dim Min Max A 0.25 0.35 B 1.20 1.40 C 2.30 2.70 H 1.60 1.80 J 0.00 0.10 K 1.0 1.1 L 0.20 0.40 M 0.10 0.15 0 8 All Dimensions in mm January 2012 (c) Diodes Incorporated SD101AWS - SD101CWS Suggested Pad Layout C Dimensions Value (in mm) Z 3.75 G 1.05 X 0.65 Y 1.35 C 2.40 X Y G Z IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright (c) 2012, Diodes Incorporated www.diodes.com SD101AWS - SD101CWS Document number: DS30078 Rev. 12 - 2 4 of 4 www.diodes.com January 2012 (c) Diodes Incorporated