DRA1 SPF Series * 10mm Single Channel DIN Rail Mount SSR Assembly * AC Ratings up to 380 VAC and 10 Amps * 3-15 VDC, 15-32VDC 18-36 VAC and 90-180 VAC control * Cage style screw terminals for easy connection * Fits standard 35mm DIN rail * Includes LED Status indicator (DC control only) PRODUCT SELECTION Description 3-15 VDC Control 4-15 VDC Control 15-32 VDC Control 90-140 Vrms Control 18-36 Vrms Control 10 A 10A DRA1-SPF240D25 DRA1-SPF240D25R (5) 10 A DRA1-SPFE240D25 DRA1-SPFE240D25R (5) 10 A DRA1-SPF380D25 DRA1-SPFE380D25 DRA1-SPF240A25 DRA1-SPFE240A25 OUTPUT SPECIFICATIONS (1) Description SPF(E)240x25 SPF(E)380x25 12-280 600 10 0.06 0.1 500 239/250 285/260 1.6 48-380** 1200 10 0.06 0.1 500 239/250 285/260 1.6 Operating Voltage [VAC] Transient Overvoltage [Vpk] Maximum Load Current [Arms] (2) (3) Minimum Load Current [Arms] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum off-state dv/dt @ maximum rated voltage [V/sec] (4) Maximum 1 Cycle Surge Current (50/60 Hz) [Apk] Maximum It for fusing (50/60 Hz, 1/2 cycle) [A sec] Maximum On-State Voltage Drop @ Rated Current [Vpk] INPUT SPECIFICATIONS (1) Description Control Voltage Range Must Turn On Voltage Must Turn Off Voltage Typycal Input Current Nominal Input Impedance Maximum Turn-On Time [msec] (5) Maximum Turn-Off Time [sec] SPF240D25 SPF380D25 SPFExxxD25 SPFxxxA25 SPFExxxA25 3-15 VDC 3.0 VDC 1 .0 VDC 15 mAdc 300 Ohm 1/2 Cycle 1/2 Cycle 4-15 VDC 4.0 VDC 1 .0 VDC 15 mAdc 240 Ohm 1/2 Cycle 1/2 Cycle 15-32 VDC 15.0 VDC 1 .0 VDC 15 mAdc 1500 Ohm 1/2 Cycle 1/2 Cycle 90-140 Vrms 90.0 Vrms 10.0 Vrms 10 mArms 14.1K Ohm 10 40 18-36 Vrms 18.0 Vrms 2.0 Vrms 10 mArms 2.1k Ohm 10 40 GENERAL SPECIFICATIONS Description Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 VDC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation Parameters 4000 VRMS 109 Ohms 8 pF -30 to 80C -30 to 125 C 0.32 lb (145.5g) Themally Conductive Epoxy GENERAL NOTES 1) All parameters at 25C unless otherwise specified. 2) See derating chart on page 3. 3) Steady state load current exceeding 10 amps will damage socket. 4) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 5) Turn-on time for DC control random turn-on versions is 0.1 msec **NOTE: Voltages in excess of 380V will damage output terminals. MECHANICAL SPECIFICATIONS WIRING DIAGRAM THERMAL DERATE INFORMATION AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 E116950 (relay only) Rev. 110811 ANNEX - ENVIROMENTAL INFORMATION