http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
TMR 3WI Series 3 Watt
Input Specifications
Input current at full load 12 Vin models: 340 mA max.
24 Vin models: 170 mA max.
48 Vin models: 85 mA max.
Input current at no load 12 Vin models: 40 mA max.
24 Vin models: 25 mA typ.
48 Vin models: 15 mA typ.
Surge voltage (100 msec. max.) 12 Vin models: 25 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
Input filter inernal capacitor
ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A
Fast transient / Surge EN 61000-4-4, ± 2 kV, perf. criteria A
EN 61000-4-5, ± 1 kV perf. criteria A
With external input capacitor e.g. Nippon
chemi-con KY 100 µF, 100 V, ESR 110 mOhm
Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Output Specifications
Voltage set accuracy ±1 % max
Regulation – Input variation Vin min. to Vin max. 0.2 % max.
– Load variation 0 – 100% single output models: 1.0 % max.
dual output models: 1.0 % max. balanced load
– Load cross regulation 25/100% 5.0 % max. (dual output models)
Minimum load not required
Temperature coefficient 0.02 %/K
Ripple and noise (20 MHz Bandwidth) 30 mVpk-pk max.
Start up time – Power On 30 ms typ.
(constant resistive load) – Remote On 30 ms typ.
Transient response setting time (25% load step change) 250 µs typ.
Short circuit protection continuous, automatic recovery
Capacitive load 3.3 VDC models: 1‘760 µF max.
5 VDC models: 1’000 µF max.
12 VDC models: 170 µF max.
15 VDC models: 110 µF max.
±5 VDC models: ±470 µF max.
±12 VDC models: ±100 µF max.
±15 VDC models: ±47 µF max.
General Specifications
Temperature ranges – Operating –40°C to +85°C
– Case temperature +100°C max.
– Storage –55°C to +125°C
Load derating 3.3 %/K above 70°C
Humidity (non condensing) 95 % rel. H max.
Reliability, calculated MTBF (MIL-HDBK-217F, @ 25°C, ground benign) >1.7 Mio h