Molded Case Circuit Breakers Molded Case Circuit Breakers - Features ........................................3-2 Spectra RMS Circuit Breakers with MicroVersaTrip Plus Trip Units - Features .....................................3-3 Molded Case Circuit Breakers - Quick Reference Guide .............3-4 Miniature Circuit Breakers and Supplementary Protectors: Plug-in Circuit Breakers - 240V Class .............................................3-5 Bolt-on Circuit Breakers - 240V Class...........................................3-12 Bolt-on Circuit Breakers - 480/277V Class ...................................3-17 Cable-in Cable-out (lug-lug) - 240V Class ....................................3-18 DIN-Rail Mount - 240V Class ..........................................................3-21 Molded Case Switches ....................................................................3-23 E2000 Miniature Circuit Breakers EP60 Series.........................................................................................3-24 EP100 Series.......................................................................................3-26 EP100 UC Series ...............................................................................3-28 Series CA Auxiliary Switch and Bell Alarm..................................3-30 Shunt Trip and Undervoltage Release...........................................3-32 Technical Data ...................................................................................3-33 Accessories........................................................................................3-34 Industrial Circuit Breakers--Spectra RMS, Spectra RMS with MicroVersaTrip Plus Trip Units, Spectra RMS with MicroVersaTrip PM Trip Units, Thermal Magnetic and J/K with MicroVersaTrip RMS-9 and Power+ 4 Trip Units: How to Order .........................................................................................3-37 MicroVersaTrip PM Trip Units - Features.....................................3-40 MicroVersaTrip PM Trip Unit Characteristics ..............................3-41 MicroVersaTrip PM Trip Units - How to Order ............................3-42 R-Frame Molded Case Circuit Breakers - How to Order...........3-43 Electric Trip Spectra RMS Breakers - Quick Reference Guide ..................................................................3-44 Electric Trip Spectra RMS Breakers - IEC/JIS Ratings .............3-45 Thermal Magnetic Trip - Quick Reference Guide .......................3-46 Molded Case Circuit Breakers - Quick Reference Guide..........3-47 15-150A Circuit Breakers, Electronic Trip, Spectra RMS ...........3-48 15-150A Circuit Breakers, Thermal-Magnetic Trip, E150 Line ...3-50 70-250A Circuit Breakers, Electronic Trip, Spectra RMS ...........3-52 70-250A Circuit Breakers, Thermal-Magnetic Trip, F225 Line ...3-54 125-400A Circuit Breakers, Thermal-Magnetic Trip, Q Line ......3-55 125-600A Circuit Breakers, Electronic Trip, Spectra RMS .........3-56 60-600A Circuit Breakers, Electronic Trip, Spectra RMS ...........3-59 60-600A Circuit Breakers, Electronic Trip, Spectra RMS with MicroVersaTrip PM Trip Units.......................................................3-59 125-600A Circuit Breakers, Thermal-Magnetic Trip, J600 Line ...........................................................................................3-62 300-1200A Circuit Breakers, Electronic Trip, Spectra RMS .......3-64 300-1200A Circuit Breakers, Electronic Trip, Spectra RMS with MicroVersaTrip Plus and PM ........................................................3-66 300-1200A Circuit Breakers, Thermal-Magnetic Trip, K1200 Line.........................................................................................3-69 400-2000A Circuit Breakers, Electronic Trip - R Frame..............3-71 150-1200A Molded Case Switches, Spectra RMS.......................3-72 3-1200A, Motor Circuit Protectors, Spectra RMS .......................3-73 50-1200A, Mine Duty Circuit Breakers, Standard Duty...............3-76 Replacement Breakers, TriBreak, Internally Fused ....................3-77 Replacement Breakers, THLC Current Limiting, Unfused ..........3-79 Replacement Breakers, J and K Frame Circuit Breakers with MicroVersa Trip Trip Units.............................................................3-80 Replacement Breakers, J and K Frame Circuit Breakers with Power+ 4 Trip Units.........................................................................3-82 Internal Accessories Spectra RMS Circuit Breakers .......................................................3-83 Molded Case Circuit Breakers........................................................3-85 Internally Mounted Signaling and Controlling Functions...........3-86 External Accessories Cable Operators.................................................................................3-92 Handle Operators ..............................................................................3-93 Flange-Mounted Operators .............................................................3-94 Door-Mounted Operators.................................................................3-96 Motor Operators and Plug-in Hardware .......................................3-98 Mechanical Interlocks and Locking Devices...............................3-99 Breaker Mounting Hardware and Kits ........................................3-100 Lugs and Associated Hardware ...................................................3-101 Neutral Grounds and Sensors ......................................................3-103 Plug-in Hardware ............................................................................3-104 R Frame Accessories......................................................................3-105 Power Management System Accessories ....................................3-106 Spectra RMS Accessories - Other .................................................3-109 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-1 Prices and data subject to change without notice MOLDED CASE CIRCUIT BREAKERS Section 3: Molded Case Circuit Breakers 3 Molded Case Circuit Breakers Molded Case Circuit Breakers Features Spectra RMS Molded Case Circuit Breakers SE150, SF250, SG600, and SK1200 circuit breaker frames have a digital, solid-state, rms sensing trip system with field installable, front-mounted rating plugs to establish or change the breaker ampere rating. Adjustable instantaneous with tracking short-time is standard on all frames including SE150. The trip system uses digital sampling to determine the rms value of sinusoidal and nonsinusoidal currents. MicroVersaTrip Plus Trip Units or MicroVersaTrip PM Trip Units SG600 and SK1200 are optionally available with either MicroVersaTrip Plus or MicroVersaTrip PM trip units which offer expanded functionality in the same space-saving size of standard Spectra RMS breakers. The trip system uses digital sampling to determine the rms value of sinusoidal and nonsinusoidal currents. MicroVersaTrip Plus Trip Units MOLDED CASE CIRCUIT BREAKERS MicroVersaTrip Plus trip units utilize a digital, LCD display with a four-button keypad to provide local set-up and readout of trip settings. A 3-phase ammeter and trip indicators are standard, as is a clear plastic cover with provisions for sealing to allow tamperresistant installation. The trip unit digitally measures the current waveform in each phase to determine the true rms value of the current, regardless of the waveshape. 3 MicroVersaTrip Plus trip units provide accurate, predictable overload and short-circuit protection for distribution systems that include ac and dc variable speed drives, rectifiers, induction heating, and other loads that cause high harmonic distortion as well as standard circuit. They provide maximum breaker-to-breaker selectivity and custom load protection. Short-time and ground fault functions include the flexibility of coordination with or without an I 2t ramp. The MicroVersaTrip PM trip unit adds power management system capability, advanced metering, and protective relays to the basic functions of the MicroVersaTrip Plus trip unit. The MicroVersaTrip PM trip unit communicates directly on the GE POWER LEADER communication bus. A complete circuit breaker consists of a UL listed circuit breaker frame and a rating plug (UL listed interchangeable trip unit). Terminal lugs for cable connection are available if required. --All frames use the same UL listed, field-installable internal accessories (auxiliary switch, shunt trip, undervoltage release and bell alarm). --All frame sizes have maximum UL listed interrupting ratings of 200 kA @ 240 Vac and 100 kA @ 480 Vac with 600 Vac ratings to 65 kA depending on frame size. UL listed current limiting versions are provided through the SG600 frame for the 65 kA @ 480 Vac and the 100 kA @ 480 Vac models, with no increase in physical frame size. --Spectra RMS Mag-Break instantaneous-only motor circuit protectors also use the same digital, solid-state trip unit and rating plugs as the circuit breakers. The interchangeable rating plug establish- Prices and data subject to change without notice Other MCCB Features --UL489 Listed --Broad product line to meet virtually any application need. --Reduced downtime. A tripped breaker is easily spotted and can be immediately reset after the fault has been corrected. --Eliminates single phasing. A common trip bar disconnects all poles simultaneously on both overloads and short circuits. --Offers application flexibility through the use of a wide variety of accessory devices and special attachments. --Repetitive operation--no fuses to replace. --Breakers can be repetitively tested. Fuses must be destroyed to confirm calibration accuracy. For more information on these products, order publications listed in Sections 21 and 22. Reference Publications Spectra RMS Molded Case Circuit Breakers GEH-5591 GEH-5663 MicroVersaTrip PM Trip Unit 3-2 es the instantaneous pickup range (with tracking short-time) but does not change the frame ampere rating. --Spectra RMS molded case switches have a fixed, high-set instantaneous trip (without tracking short-time function) and have short-circuit withstand ratings equal to their equivalent breaker frame size interrupting rating in most cases. --Spectra RMS breakers are ambient insensitive. Trip times will not vary over the range 10-50C breaker ambient. Refer to GET-7002 for further application information. --Spectra RMS breakers contain no parts that would support fungus growth and are, therefore, inherently fungusproof. BuyLog Catalog GEH-5592 GEH-5934 GEH-5887 GEH-5549 GEH-5551 GEH-5593 GEH-5885 DEJ-001 GEH-6250 GEH-6251 GEH-6252 GEH-6253 GEH-6254 GEH-6255 GEH-6256 GEH-6257 GEH-6258 SE150 & SF250 SG600 SG600 with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units SK1200 SK1200 with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units MicroVersaTrip Plus and MicroVersaTrip PM Trip Units in Spectra RMS Molded Case Circuit Breakers Micro-VersaTrip Plus and MicroVersaTrip PM Rating Plugs Standard Rating Plugs Shunt Trip/UV Release Auxiliary Switch/Bell Alarm R-Frame Molded Case Circuit Breakers TVPBP Portable Battery Pack Voltage Module Power Supply Plate Voltage Conditioner Plate Power Supply Assembly Voltage Conditioner Assembly Distribution Cable Harness Distribution Cable Extension Distribution Cable Terminal Block Distribution Cable Junction Box NOTE: NEMA ABI (1975) has been superceded by UL489 www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Spectra RMS Circuit Breakers with MicroVersaTrip Plus Trip Units Features MicroVersaTrip Plus Trip Units Standard --3-phase Ammeter with 4% accuracy. --Adjustable Long Time (L) pickup, 0.5-1.0X, and delay (3-4 bands). --Adjustable Instantaneous (I) pickup, 1.5-10X. --Local Overload and Short Circuit Trip Indicators (T) with overload pickup warning. --Interchangeable trip ratings plugs with test set jack for TVRMS test set. --Digital LCD display with four-button keypad for function selection and set point adjustment and sealable, clear Lexan cover for tamper-resistant settings. --True rms sensing for accurate response to high harmonic content waveforms. --EMI immunity per ANSI C37.90. Optional --Adjustable Short-Time (S) pickup, 1.0-9.0C, and delay (4 bands) with I2t IN/OUT selection. --Adjustable Ground fault (G) pickup, 0.2-1.0S, and delay (4 bands) with I2t IN/OUT selection and trip indicator. The 4 short-time and ground fault delay bands provide broader system selectivity. SG Frame with MicroVersaTrip Plus Trip Unit Wide Current Setting Range--Interchangeable rating plugs combined with 5 current sensors and 0.5-1.0X long time pickup yield ampere ratings from 30 to 1200A. World Standards--Frames rated to UL, CSA, IEC 947-2, and JIS. 100% Continuous Current Rated--Optionally available for 100% UL continuous current rating applications. Universal Internal Accessories--Uses the same front-mounted, field installable shunt trips, undervoltage releases, bell alarms, and auxiliary switches as standard Spectra RMS breakers. Control Power 24 Vdc--Optionally available, provides connection capability for +24 Vdc into the breaker via the distribution cable system. MOLDED CASE CIRCUIT BREAKERS Accessory Lead Routing Left or Right--Side channels mean no extra space required for accessory leads. Current Limiting--SE150, SF250 and SG600 frames rated 65kA and 100kA @ 480 Vac are UL listed as current limiting. Reverse Feed--Front-mounted interchangeable rating plugs mean all frames are UL listed for reverse feed. MicroVersaTrip Plus Trip Unit Characteristics1 Current Setting (C) (Pick-Up) (Multiple of Rating Plug Amperes) (X) 0.5 to 1.0 in increments of 0.05 Long-Time 2 3 Short-Time Delay (Seconds) 3,4 2.4, 4.9, 9.8, 20 Pick-Up (Multiple of Current Setting) (C) 1.5 to 9.0 in increments of 0.5 Delay (Seconds) I2 t in;4 .44 I2 t out;6 .10, .20, .30, .40 Adjustable Instantaneous Pick-Up (Multiple of Rating Plug Amperes) (X) 1.5 to 10.0 in increments of 0.5 Ground Fault Pick-Up (Multiple of Sensor Ampere Rating) (X) Delay (Seconds) I 2 t in;5 .41 .20 to 1.00 in increments of .05 I 2 t out;6 .10, .20, .30, .40 X = Rating Plug Amperes S = Sensor Ampere Rating C = Long-Time Current Settings (Pick-Up) 1 Contact local GE Sales Office for use on 400 Hz applications. Not UL listed for 400 Hz. 2 Pick-up fixed at 1.1C. 3 20 second delay (band) not available on SG frames. 4 Time delay at 600% of current setting at lower limit of each band. 5Time delay at 200% of pick-up setting at lower limit of band. 6 Time delay shown at lower limit of each band. Pick-up tolerances 10%. Ground fault pick-up not to exceed 1200 amperes. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-3 Prices and data subject to change without notice Molded Case Circuit Breakers Molded Case Circuit Breakers Quick Reference Guide Ratings do not apply to molded case switches. The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage. Q Line (UL file E-11592; Fixed Thermal Magnetic Trip Unit) Circuit Breaker Type TQ THQP 1 Ampere Rating No. Poles 15-50 1 120/240 15-60 2 120/240 1 15-50 10 THHQB1 THHQC1 15-70 1 15-125 2 15-100 3 15-70 1 15-100 MOLDED CASE CIRCUIT BREAKERS 3 15-70 1 15-125 2 15-100 3 1 TXQL1 TXQB1 TXQC1 15-30 TQDL THQDL TQD1 THQD1 TJD TEY1 Vac dc 120 -- -- -- -- Vdc 120/240 240 10 -- 10 -- 10 -- Dimensions (in.) 277 480 600 125 250 H -- -- -- -- -- 3 -- -- -- -- -- 3 9/32 W 3/4 D A B C E 2 3/8 -- -- -- -- -- 120/240 -- -- 52 -- 240 52 -- -- -- -- 3 9/32 5 100 2 3/8 -- -- -- -- -- 240 -- 120/240 22 10 -- -- -- -- -- 3 9/32 -- -- 240 22 -- -- -- -- -- 3 9/32 22 -- -- -- 240 22 -- -- -- -- -- 3 9/32 120/240 -- -- -- -- 2 2 65 -- -- -- -- -- 3 9/32 25 15 50 2 3/8 -- -- -- -- 25 15 50 2 3/8 -- -- -- -- 25 3 15 1 50 2 2 3/8 -- -- -- -- 2 25 15 1 65 -- -- 3 -- 2 -- 1 -- 120/240 50 2 3/8 3 -- -- 2 1 10 -- 50 3 -- 120/240 10 1/2 1 -- Std. Pack 1 1/2 1 2 3 THHQL1 120/240 2 3 THQL1 THQB1 THQC1 ac 2 1 TQL/TQB/ TQC UL Listed Interrupting Ratings-- rms Symmetrical kA Maximum Voltage Rating 50 2 3/8 -- -- -- -- 240 125-200 2 120/240 -- -- 10 -- -- -- -- -- -- 6 1/16 2 2 3/8 -- -- -- -- 12 125-200 2 120/240 -- -- 22 -- -- -- -- -- -- 6 1/16 2 2 3/8 -- -- -- -- 12 100-225 2 240 10 10 100-225 3 240 -- 10 100-225 2 240 22 22 100-225 3 240 -- 22 2 240 22 22 3 240 -- 22 1 277 250-400 15-100 2 3 480/277 -- -- -- 125 250 -- -- -- 65 -- 3 25 3 -- -- -- -- 6 9/16 -- 2 5/8 2 7/16 2 7/16 4 1/8 -- -- -- -- -- 6 9/16 2 3/4 -- -- 14 14 -- 65 14 -- -- 10 10 1/8 8 1/4 27/32 11/16 2 7/16 2 7/16 1 1 -- 2 5/8 4 1/8 27/32 11/16 1 1 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16 1 1 -- -- -- 2 3/4 15 14 3 -- 10 -- 10 10 -- -- 1 5 1/4 2 3 1/16 -- -- -- -- 2 3/8 -- -- -- -- -- 3 CB3 Ground Fault, Equipment Ground Fault and Arc Fault (UL File E-51075; Fixed Thermal Magnetic Trip Unit) THQB THQC THQL ...GF, GFEP, AF 15-30 THHQL ...GF THHQB ...GF, GFEP, AF 15-30 1 120 10 -- -- 2 120/240 1 120 -- 1 -- -- 1 22 -- -- -- -- -- -- 3 9/32 10 2 -- -- -- -- -- -- 3 9/32 1 10 2 3/8 -- -- -- -- 10 1 UL listed as HACR (heating, air conditioning and refrigeration). 2 3 Not UL listed. 480Y/277 Vac 3-4 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class TQL and THQL 120/240 Vac 1 1 1 1 1 1 1 1 1 1 1 Ampere Rating GO-138A 120/240 Vac Interrupting Rating 10 152 202 25 30 35 40 45 50 60 70 5kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA Wire Range1 Product Number List Price (1) 14-8 Cu/12-8 Al (1) 14-8 Cu/12-8 Al (1) 14-8 Cu/12-8 Al (1) 14-8 Cu/12-8 Al (1) 8-3 Cu/8-3 Al (1) 8-3 Cu/8-3 Al (1) 8-3 Cu/8-3 Al (1) 8-3 Cu/8-3 Al (1) 8-3 Cu/8-3 Al (1) 6-1/0 Cu/4-1/0 Al TQL1110 THQL1115 THQL1120 THQL1125 THQL1130 THQL1135 THQL1140 THQL1145 THQL1150 THQL1160 THQL1170 $20.00 $20.25 $20.25 $20.25 $20.25 $21.25 $21.25 $21.25 $21.25 $21.25 $42.50 TQL and THQL 120/240 Vac, Internal Common Trip # of Poles 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Ampere Rating 120/240 Vac Interrupting Rating 102 5kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 Wire Range1 (1) 14-8 Cu/12-8 Al (1) 14-8 Cu/12-8 Al (1) 14-8 Cu/12-8 Al (1) 14-8 Cu/12-8 Al (1) 8-3 Cu/8-3 Al (1) 8-3 Cu/8-3 Al (1) 8-3 Cu/8-3 Al (1) 8-3 Cu/8-3 Al (1) 8-3 Cu/8-3 Al (1) 6-1/0 Cu/4-1/0 Al (1) 6-1/0 Cu/4-1/0 Al (1) 6-1/0 Cu/4-1/0 Al (1) 6-1/0 Cu/4-1/0 Al (1) 2-2/0 Cu/2-2/0 Al (1) 2-2/0 Cu/2-2/0 Al GO-138A Product Number TQL2110 THQL2115 THQL2120 THQL2125 THQL2130 THQL2135 THQL2140 THQL2145 THQL2150 THQL2160 THQL2170 THQL2180 THQL2190 THQL21100 THQL21110 THQL211253 THQP 120/240 Vac # of Poles 1 1 1 1 1 1 1 1 THQL1120 List Price $46.00 $46.00 $46.00 $46.00 $46.00 $47.75 $47.75 $47.75 $47.75 $47.75 $95.00 $131.00 $131.00 $131.00 $284.00 $284.00 MOLDED CASE CIRCUIT BREAKERS # of Poles GO-138A Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 15 20 25 30 35 40 45 50 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-4 Cu/8-4 Al 8-4 Cu/8-4 Al 8-4 Cu/8-4 Al 8-4 Cu/8-4 Al 8-4 Cu/8-4 Al Product Number THQP115 THQP120 THQP125 THQP130 THQP135 THQP140 THQP145 THQP150 List Price $20.25 $20.25 $20.25 $20.25 $21.25 $21.25 $21.25 $21.25 3 1Solid or stranded for 14-10 AWG. 2UL listed as SWD (Switching Duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. 3Recommended for use as main or submain breaker only. UL listed as HACR (heating, air conditioning and refrigeration). Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-5 Prices and data subject to change without notice Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class THQP 120/240 Vac, Internal Common Trip # of Poles 2 2 2 2 2 2 2 2 GO-138A Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 15 20 25 30 35 40 45 50 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-4 Cu/8-4 Al 8-4 Cu/8-4 Al 8-4 Cu/8-4 Al 8-4 Cu/8-4 Al 8-4 Cu/8-4 Al Product Number THQP215 THQP220 THQP225 THQP230 THQP235 THQP240 THQP245 THQP250 List Price $46.00 $46.00 $46.00 $46.00 $47.75 $47.75 $47.75 $47.75 15-100 ampere UL Listed as HACR (heating, air conditioning and refrigeration). THQP230 TQL and THQL 120/240 Vac, Internal Common Trip # of Poles Ampere Rating 2 2 2 2 2 2 2 2 2 2 2 2 2 2 10 15 20 25 30 35 40 45 50 60 70 80 90 100 120/240 Vac Interrupting Rating 5kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA Wire Range1 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al GO-138 Product Number List Price TQL22010 THQL22015 THQL22020 THQL22025 THQL22030 THQL22035 THQL22040 THQL22045 THQL22050 THQL22060 THQL22070 THQL22080 THQL22090 THQL22100 $133.00 $133.00 $133.00 $133.00 $133.00 $133.00 $133.00 $133.00 $133.00 $133.00 $156.00 $221.00 $221.00 $221.00 THQL32015 MOLDED CASE CIRCUIT BREAKERS TQL and THQL 240 Vac, Internal Common Trip 3 # of Poles Ampere Rating 3 3 3 3 3 3 3 3 3 3 3 3 3 3 10 15 20 25 30 35 40 45 50 60 70 80 90 100 240 Vac Interrupting Rating 5kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA GO-138 Wire Range1 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al Product Number List Price TQL32010 THQL32015 THQL32020 THQL32025 THQL32030 THQL32035 THQL32040 THQL32045 THQL32050 THQL32060 THQL32070 THQL32080 THQL32090 THQL32100 $165.00 $165.00 $165.00 $165.00 $165.00 $165.00 $165.00 $165.00 $165.00 $165.00 $216.00 $245.00 $245.00 $245.00 THQL and THHQL 120/240 Vac Arc Fault # of Poles 1 1 1 1 Ampere Rating 120/240 Vac Interrupting Rating 15 20 15 20 10kA 10kA 22kA 22kA GO-146A Wire Range1 14-10 14-10 14-10 14-10 Cu/14-10 Al Cu/14-10 Al Cu/14-10 Al Cu/14-10 Al Product Number List Price THQL1115AF THQL1120AF THHQL1115AF THHQL1120AF $170.00 $170.00 $326.00 $326.00 THQL and THHQL 120/240 Vac Arc Fault # of Poles 2 2 2 2 Ampere Rating 120/240 Vac Interrupting Rating 15 20 15 20 10kA 10kA 22kA 22kA THQL1115AF GO-146A Wire Range1 14-10 14-10 14-10 14-10 Cu/14-10 Al Cu/14-10 Al Cu/14-10 Al Cu/14-10 Al Product Number List Price THQL2115AF THQL2120AF THHQL2115AF THHQL2120AF $385.00 $385.00 $701.00 $701.00 THQL2115AF 1Solid or stranded for 14-10 AWG. 3-6 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class THQL and THHQL 120 Vac, Ground Fault Circuit Interrupters 1 1 1 1 1 1 Ampere Rating 120 Vac Interrupting Rating 15 20 30 15 20 30 10kA 10kA 10kA 22kA 22kA 22kA Wire Range1 14-8 14-8 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al GO-146 Product Number List Price THQL1115GF THQL1120GF THQL1130GF THHQL1115GF THHQL1120GF THHQL1130GF $159.00 $159.00 $159.00 $311.00 $311.00 $311.00 THQL and THHQL 120/240 Vac or 208Y/120 Vac, Ground Fault Circuit Interrupters Internal Common Trip # of Poles 2 2 2 2 2 GO-146 Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 Product Number List Price 15 20 30 40 50 10kA 10kA 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al THQL2115GF1 THQL2120GF1 THQL2130GF1 THQL2140GF1 THQL2150GF1 $282.00 $282.00 $282.00 $282.00 $702.00 THQL and THHQL 120 Vac, Equipment Protection Ground Fault Circuit Breakers Internal Common Trip # of Poles 1 1 1 Ampere Rating 120 Vac Interrupting Rating Wire Range1 15 20 30 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al GO-146 Product Number List Price THQL1115GFEP THQL1120GFEP THQL1130GFEP $271.00 $271.00 $271.00 THQL and THHQL 120/240 Vac or 208Y/120 Vac, Equipment Protection Ground Fault Circuit Breakers # of Poles 2 2 2 Ampere Rating 120/240 Vac or 208Y/120 Interrupting Rating Wire Range1 15 20 30 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al GO-146 Product Number List Price THQL2115GFEP THQL2120GFEP THQL2130GFEP $481.00 $481.00 $481.00 THQL Interlocking--for use in PowerMark Gold Generator Panels # of Poles 2 2 THQL1120GF MOLDED CASE CIRCUIT BREAKERS # of Poles GO-138A Ampere Rating 120/240 Vac or 208Y/120 Interrupting Rating Wire Range1 Product Number List Price 30 60 10kA 10kA 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al THQL2130GEN THQL2160GEN $238.75 $238.75 3 Two breakers required for interlocking. TQ Circuit Breakers 120/240 Vac GO-138Q 3/4" UL Classified Circuit Breakers for use in Square D QO Load Centers. 10 kAIC RMS symmetrical. # of Poles 1 1 1 1 1 2 2 2 2 2 2 Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 Product Number List Price 15 20 30 40 50 15 20 30 40 50 60 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-2 Cu/8-2 Al 8-2 Cu/8-2 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-2 Cu/8-2 Al 8-2 Cu/8-2 Al 8-2 Cu/8-2 Al TQ1115 TQ1120 TQ1130 TQ1140 TQ1150 TQ2115 TQ2120 TQ2130 TQ2140 TQ2150 TQ2160 $20.25 $20.25 $20.25 $20.25 $20.25 $46.00 $46.00 $46.00 $46.00 $46.00 $46.00 1Solid or stranded for 14-10 AWG. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-7 Prices and data subject to change without notice Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class THQL and THHQL 120/240 Vac, High Intensity Discharge Lighting Loads GO-138A # of Poles List Price Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 15 20 25 30 10kA 10kA 10kA 10kA 22kA 22kA 22kA 22kA 1 1 1 1 1 1 1 1 Wire Range1 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Product Number THQL1115HID2 THQL1120HID2 THQL1125HID THQL1130HID THHQL1115HID2 THHQL1120HID2 THHQL1125HID THHQL1130HID $26.00 $26.00 $26.00 $26.00 $49.50 $49.50 $49.50 $49.50 UL listed as HID. THQL2120HID THQL and THHQL 120/240 Vac, Internal Common Trip For High Intensity Discharge Lighting Loads GO-138A # of Poles Product Number List Price THQL2115HID THQL2120HID THQL2125HID THQL2130HID THHQL2115HID THHQL2120HID THHQL2125HID THHQL2130HID $57.00 $57.00 $57.00 $57.00 $119.00 $119.00 $119.00 $119.00 Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 15 20 25 30 10kA 10kA 10kA 10kA 22kA 22kA 22kA 22kA 2 2 2 2 2 2 2 2 Wire Range1 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al UL listed as HID. THQL 120/240 Vac, High In-Rush Loads MOLDED CASE CIRCUIT BREAKERS # of Poles 3 1 1 1 1 1 1 GO-138A Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 Product Number List Price 15 20 25 30 40 50 10kA 10kA 10kA 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al THQL1115HM THQL1120HM THQL1125HM THQL1130HM THQL1140HM THQL1150HM $26.00 $26.00 $26.00 $26.00 $26.75 $26.75 THQL 120 Vac, For Factory Installed Shunt Trip 3,4 Internal Common Trip # of Poles 3 Ampere Rating 120 Vac Interrupting Rating Wire Range1 20 10kA 14-8 Cu/12-8 Al Product Number List Price THQL32020ST1 $273.00 THQL 120/240 Vac, Thermal Magnetic Pole plus Nonautomatic Pole For Switching Neutral # of Poles 2 2 2 2 3 3 3 3 Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 15 20 25 30 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA Wire Range1 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al GO-138 THQL1120HM GO-138A Product Number List Price THQL21WY15 THQL21WY20 THQL21WY25 THQL21WY30 THQL31WY15 THQL31WY20 THQL31WY25 THQL31WY30 $74.25 $74.25 $74.25 $74.25 $111.00 $111.00 $111.00 $111.00 1Solid or stranded for 14-10 AWG. 2UL listed as SWD (switching duty). Suitable for 120 Vac fluorescent lighting loads. 3For additional shunt trip offerings see page 3-88. 420-60 ampere are UL listed as HACR (heating, air conditioning and refrigeration). 3-8 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class THQMV Top-Feed Main Circuit Breaker Kits for use with 150A-225A PowerMark Gold Load Centers 2 2 2 2 2 2 Ampere Rating Interrupting Rating @ System Voltage 100 125 150 175 200 225 22kA 22kA 22kA 22kA 22kA 22kA GO-138M Wire Range1 Product Number List Price 6-350 6-350 6-350 6-350 6-350 6-350 THQMV100 THQMV125 THQMV150 THQMV175 THQMV200 THQMV225 $259.00 $259.00 $259.00 $259.00 $259.00 $259.00 Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al THQMV Bottom-Feed Main Circuit Breaker Kits for use with 150A-225A PowerMark Gold Load Centers Internal Common Trip # of Poles 2 2 2 2 2 2 Ampere Rating Interrupting Rating @ System Voltage 100 125 150 175 200 225 22kA 22kA 22kA 22kA 22kA 22kA GO-138M Wire Range1 Product Number List Price 6-350 6-350 6-350 6-350 6-350 6-350 THQMV100B THQMV125B THQMV150B THQMV175B THQMV200B THQMV225B $259.00 $259.00 $259.00 $259.00 $259.00 $259.00 Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al THLK Sub-free and Feed-through Lugs Internal Common Trip # of Poles 2 3 2 2 3 Ampere Rating Wire Range1 125 125 150 200 225 2-3/0 Cu/Al 2-3/0 Cu/Al 2-3/0 Cu/Al 6-250 Cu/Al 6-300 Cu/Al 2 2 2 2 Ampere Rating 120/240 Vac Interrupting Rating 125 150 175 200 10kA 10kA 10kA 10kA THQMV200B GO-137A Product Number THLK2125 THLK3125 THLK21502 THLK22002 THLK32253 TQDL 120/240 Vac, Internal Common Trip # of Poles THQMV200 List Price THLK2125 $77.00 $107.00 $137.00 $158.00 $250.00 GO-138A Wire Range1 1/0-250 1/0-250 1/0-250 1/0-250 Cu/Al Cu/Al Cu/Al Cu/Al Product Number List Price TQDL21125 TQDL21150 TQDL21175 TQDL21200 $296.00 $296.00 $296.00 $296.00 THKL2150 1Solid or stranded for 14-10 AWG. 3 2For use with PowerMark Gold load centers only. 3For use with three-phase load centers only. Includes mounting base. UL listed as HACR (heating, air conditioning and refrigeration). Requires four one-inch spaces. TQDL21200 THQP130 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com MOLDED CASE CIRCUIT BREAKERS # of Poles BuyLog Catalog 3-9 Prices and data subject to change without notice Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class THHQL 120 Vac # of Poles 1 1 1 1 1 1 1 1 1 1 GO-138A Ampere Rating 120 Vac Interrupting Rating Wire Range1 15 20 25 30 35 40 45 50 60 70 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al Product Number THHQL11152 THHQL11202 THHQL1125 THHQL1130 THHQL1135 THHQL1140 THHQL1145 THHQL1150 THHQL1160 THHQL1170 THHQL 120/240 Vac, Internal Common Trip # of Poles 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 List Price $40.25 $40.25 $40.25 $40.25 $41.25 $41.25 $41.25 $41.25 $41.25 $58.50 THHQL1120 GO-138A Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 2-2/0 Cu/2-2/0 Al 2-2/0 Cu/2-2/0 Al Product Number List Price THHQL2115 THHQL2120 THHQL2125 THHQL2130 THHQL2135 THHQL2140 THHQL2145 THHQL2150 THHQL2160 THHQL2170 THHQL2180 THHQL2190 THHQL21100 THHQL21110 THHQL21125 $93.00 $93.00 $93.00 $93.00 $97.00 $97.00 $97.00 $97.00 $97.00 $148.00 $210.00 $210.00 $210.00 $686.00 $686.00 1Solid or stranded for 14-10 AWG. MOLDED CASE CIRCUIT BREAKERS 2UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. UL listed HACR (heating, air conditioning and refrigeration). 3 3-10 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class THHQL 240 Vac, Internal Common Trip # of Poles 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 GO-138 Ampere Rating 240 Vac Interrupting Rating Wire Range1 Product Number List Price 15 20 25 30 35 40 45 50 60 70 80 90 100 15 20 25 30 35 40 45 50 60 70 80 90 100 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al THHQL22015 THHQL22020 THHQL22025 THHQL22030 THHQL22035 THHQL22040 THHQL22045 THHQL22050 THHQL22060 THHQL22070 THHQL22080 THHQL22090 THHQL22100 THHQL32015 THHQL32020 THHQL32025 THHQL32030 THHQL32035 THHQL32040 THHQL32045 THHQL32050 THHQL32060 THHQL32070 THHQL32080 THHQL32090 THHQL32100 $193.00 $193.00 $193.00 $193.00 $193.00 $193.00 $193.00 $193.00 $193.00 $251.00 $277.00 $277.00 $277.00 $251.00 $251.00 $251.00 $251.00 $251.00 $251.00 $251.00 $251.00 $251.00 $329.00 $359.00 $359.00 $359.00 THHQL32015 UL listed HACR (heating, air conditioning and refrigeration). # of Poles 2 2 2 2 Ampere Rating 120/240 Vac Interrupting Rating 125 150 175 200 22kA 22kA 22kA 22kA GO-138 Wire Range1 1/0-250 1/0-250 1/0-250 1/0-250 Cu/1/0-250 Al Cu/1/0-250 Al Cu/1/0-250 Al Cu/1/0-250 Al Product Number List Price THQDL21125 THQDL21150 THQDL21175 THQDL21200 $713.00 $713.00 $713.00 $713.00 TXQL 120/240 Vac # of Poles 1 1 1 1 GO-138A Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 65kA 65kA 65kA 65kA Wire Range1 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Product Number TXQL11152 TXQL11202 TXQL1125 TXQL1130 TXQL 120/240 Vac, Internal Common Trip # of Poles 2 2 2 2 3 3 3 3 MOLDED CASE CIRCUIT BREAKERS THQDL 120/240 Vac, Internal Common Trip Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 15 20 25 30 65kA 65kA 65kA 65kA 65kA 65kA 65kA 65kA List Price $74.75 $74.75 $74.75 $74.75 3 GO-138A Wire Range1 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Product Number List Price TXQL2115 TXQL2120 TXQL2125 TXQL2130 TXQL32015 TXQL32020 TXQL32025 TXQL32030 $186.00 $186.00 $186.00 $186.00 $348.00 $348.00 $348.00 $348.00 1Solid or stranded for 14-10 AWG. 2UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. UL listed HACR (heating, air conditioning and refrigeration). Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-11 Prices and data subject to change without notice Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Bolt-on Circuit Breakers 240V Class TQB, THQB 120/240 Vac # of Poles 1 1 1 1 1 1 1 1 1 1 1 GO-135B Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 10 15 20 25 30 35 40 45 50 60 70 5kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al Product Number TQB1110 THQB11152 THQB11202 THQB1125 THQB1130 THQB1135 THQB1140 THQB1145 THQB1150 THQB1160 THQB1170 TQB, THQB 120/240 Vac, Internal Common Trip # of Poles MOLDED CASE CIRCUIT BREAKERS 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 $19.75 $19.75 $19.75 $19.75 $19.75 $19.75 $19.75 $19.75 $19.75 $19.75 $38.00 THQB2115 GO-135B Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 10 15 20 25 30 35 40 45 50 60 70 80 90 100 5kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al Product Number List Price TQB2110 THQB2115 THQB2120 THQB2125 THQB2130 THQB2135 THQB2140 THQB2145 THQB2150 THQB2160 THQB2170 THQB2180 THQB2190 THQB21100 $43.50 $43.50 $43.50 $43.50 $43.50 $43.50 $43.50 $43.50 $43.50 $43.50 $82.50 $113.00 $113.00 $113.00 TQB, THQB 240 Vac, Internal Common Trip # of Poles List Price GO-135B Ampere Rating 240 Vac Interrupting Rating Wire Range1 10 15 20 25 30 35 40 45 50 60 70 80 90 100 10 15 20 25 30 35 40 45 50 60 70 80 90 100 5kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 5kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al Product Number List Price TQB22010 THQB22015 THQB22020 THQB22025 THQB22030 THQB22035 THQB22040 THQB22045 THQB22050 THQB22060 THQB22070 THQB22080 THQB22090 THQB22100 TQB320103 THQB32015 THQB32020 THQB32025 THQB32030 THQB32035 THQB32040 THQB32045 THQB32050 THQB32060 THQB32070 THQB32080 THQB32090 THQB32100 $113.00 $113.00 $113.00 $113.00 $113.00 $113.00 $113.00 $113.00 $113.00 $113.00 $148.00 $170.00 $170.00 $170.00 $139.00 $139.00 $139.00 $139.00 $139.00 $139.00 $139.00 $139.00 $139.00 $139.00 $175.00 $199.00 $199.00 $199.00 1Solid or stranded for 14-10 AWG. 2UL listed as SWD (Switching Duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. 3Not UL listed. UL listed HACR (heating, air conditioning and refrigeration). 3-12 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Bolt-on Circuit Breakers 240V Class # of Poles 1 1 1 1 1 1 Ampere Rating 120 Vac Interrupting Rating 15 20 30 15 20 30 10kA 10kA 10kA 22kA 22kA 22kA GO-133 Wire Range1 14-8 14-8 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Product Number List Price THQB1115GF THQB1120GF THQB1130GF THHQB1115GF THHQB1120GF THHQB1130GF $120.00 $120.00 $120.00 $235.00 $235.00 $235.00 THQB 120/240 or 208Y/120 Vac, Ground Fault Breakers, Internal Common Trip # of Poles 2 2 2 120/240 or 208Y/120 Vac Interrupting Rating Wire Range1 Product Number List Price 15 20 30 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al THQB2115GF THQB2120GF THQB2130GF $212.00 $212.00 $212.00 THQB 120 Vac, Equipment Protection Ground Fault Circuit Breakers (30 ma) # of Poles 1 1 1 Ampere Rating 120 Vac Interrupting Rating Wire Range1 15 20 30 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 2 2 2 Ampere Rating 120/240 or 208Y/120 Vac Interrupting Rating Wire Range1 15 20 30 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al List Price THQB1115GFEP THQB1120GFEP THQB1130GFEP $205.00 $205.00 $205.00 1 1 1 1 Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 10kA 10kA 10kA 10kA Wire Range1 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al THQB1115GF GO-133 Product Number List Price THQB2115GFEP THQB2120GFEP THQB2130GFEP $273.00 $273.00 $273.00 THQB 120/240 Vac, High Intensity Discharge Lighting Loads # of Poles GO-133 Product Number THQB 120/240 or 208Y/120 Vac, Ground Fault Breakers Equipment Protection Ground Fault Circuit Breakers, Internal Common Trip # of Poles GO-133 Ampere Rating MOLDED CASE CIRCUIT BREAKERS THQB, THHQB 120 Vac, Ground Fault Breakers GO-135B Product Number List Price THQB1115HID2 THQB1120HID2 THQB1125HID THQB1130HID $23.75 $23.75 $23.75 $23.75 3 UL listed as HID (high intensity discharge). THHQB 120/240 Vac, High Intensity Discharge Lighting Loads # of Poles 1 1 1 1 Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 22kA 22kA 22kA 22kA Wire Range1 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al GO-135B Product Number THHQB1115HID2 THHQB1120HID2 THHQB1125HID THHQB1130HID List Price $41.50 $41.50 $47.00 $47.00 1Solid or stranded for 14-10 AWG. 2UL listed as SWD (switching duty). Suitable for switching 120 Vac fluorescent lighting loads. UL listed as HID (high intensity discharge). Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-13 Prices and data subject to change without notice Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Bolt-on Circuit Breakers 240V Class THQB 120/240 Vac, Internal Common Trip, High Intensity Discharge Lighting Loads # of Poles 2 2 2 2 Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 10kA 10kA 10kA 10kA Wire Range1 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al GO-135B Product Number List Price THQB2115HID THQB2120HID THQB2125HID THQB2130HID $52.50 $52.50 $52.50 $52.50 UL listed as HID THHQB 120/240 Vac, Internal Common Trip, High Intensity Discharge Lighting Loads GO-135B # of Poles List Price 2 2 2 2 Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 22kA 22kA 22kA 22kA Wire Range1 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Product Number THHQB2115HID THHQB2120HID THHQB2125HID THHQB2130HID $98.50 $98.50 $98.50 $98.50 UL listed as HID THQB 120 Vac with Factory Installed 120 Vac Shunt Trip 2,3 # of Poles 1 GO-135B Ampere Rating 120 Vac Interrupting Rating Wire Range1 Product Number List Price 20 10kA 14-8 Cu/12-8 Al THQB1120ST1 $113.00 THQB 120 Vac, Internal Common Trip with Factory Installed 120 Vac Shunt Trip 2,3 GO-135B MOLDED CASE CIRCUIT BREAKERS # of Poles 3 2 2 2 3 3 3 3 3 3 3 3 3 Ampere Rating 120 Vac Interrupting Rating Wire Range1 20 30 100 20 30 40 50 60 70 80 90 100 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 6-1/0 Cu/4-1/0 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al Product Number List Price THQB2120ST1 THQB2130ST1 THQB21100ST1 THQB32020ST1 THQB32030ST1 THQB32040ST1 THQB32050ST1 THQB32060ST1 THQB32070ST1 THQB32080ST1 THQB32090ST1 THQB32100ST1 $137.00 $137.00 $205.00 $234.00 $234.00 $234.00 $234.00 $234.00 $270.00 $295.00 $295.00 $295.00 THQB 120 Vac with Switching Neutral Single Thermal Magnetic Pole; Single Nonautomatic Pole GO-138A # of Poles Product Number List Price THQB21WY15 THQB21WY20 THQB21WY25 THQB21WY30 $58.50 $58.50 $58.50 $58.50 2 2 2 2 Ampere Rating 120 Vac Interrupting Rating 15 20 25 30 10kA 10kA 10kA 10kA Wire Range1 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al THQB 120 Vac with Switching Neutral Two Thermal Magnetic Pole; Single Nonautomatic Pole # of Poles 3 3 3 3 Ampere Rating 120 Vac Interrupting Rating 15 20 25 30 10kA 10kA 10kA 10kA Wire Range1 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al GO-135B Product Number List Price THQB31WY15 THQB31WY20 THQB31WY25 THQB31WY30 $88.00 $88.00 $88.00 $88.00 1Solid or stranded for 14-10 AWG. 2For additional shunt trip offerings see page 3-88. 320-60 ampere are UL listed as HACR (heating, air conditioning and refrigeration). 3-14 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Bolt-on Circuit Breakers 240V Class THHQB 120/240 Vac 1 1 1 1 1 1 1 1 1 1 GO-135B Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 Product Number List Price 15 20 25 30 35 40 45 50 60 70 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al THHQB11152 THHQB11202 THHQB1125 THHQB1130 THHQB1135 THHQB1140 THHQB1145 THHQB1150 THHQB1160 THHQB1170 $35.00 $35.00 $39.00 $39.00 $39.00 $39.00 $39.00 $39.00 $39.00 $51.00 THHQB 120/240 Vac, Internal Common Trip # of Poles 2 2 2 2 2 2 2 2 2 2 2 2 2 GO-135B Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 Product Number List Price 15 20 25 30 35 40 45 50 60 70 80 90 100 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al THHQB2115 THHQB2120 THHQB2125 THHQB2130 THHQB2135 THHQB2140 THHQB2145 THHQB2150 THHQB2160 THHQB2170 THHQB2180 THHQB2190 THHQB21100 $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $126.00 $183.00 $183.00 $183.00 THHQB 240 Vac, Internal Common Trip # of Poles 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 THHQB2115 GO-135B Ampere Rating 240 Vac Interrupting Rating Wire Range1 Product Number List Price 15 20 25 30 35 40 45 50 60 70 80 90 100 15 20 25 30 35 40 45 50 60 70 80 90 100 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al THHQB22015 THHQB22020 THHQB22025 THHQB22030 THHQB22035 THHQB22040 THHQB22045 THHQB22050 THHQB22060 THHQB22070 THHQB22080 THHQB22090 THHQB22100 THHQB32015 THHQB32020 THHQB32025 THHQB32030 THHQB32035 THHQB32040 THHQB32045 THHQB32050 THHQB32060 THHQB32070 THHQB32080 THHQB32090 THHQB32100 $156.00 $156.00 $156.00 $156.00 $156.00 $156.00 $156.00 $156.00 $156.00 $196.00 $235.00 $235.00 $235.00 $212.00 $212.00 $212.00 $212.00 $212.00 $212.00 $212.00 $212.00 $212.00 $263.00 $307.00 $307.00 $307.00 MOLDED CASE CIRCUIT BREAKERS # of Poles 3 1Solid or stranded for 14-10 AWG. 2UL listed as SWD (switching duty). Suitable for switching 120 Vac fluorescent lighting loads. UL listed HACR (heating, air conditioning and refrigeration). Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-15 Prices and data subject to change without notice Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Bolt-on Circuit Breakers 240V Class TXQB 120/240 Vac # of Poles 1 1 1 1 GO-135B Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 65kA 65kA 65kA 65kA Wire Range1 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Product Number TXQB11152 TXQB11202 TXQB1125 TXQB1130 TXQB 120/240 Vac, Internal Common Trip # of Poles 2 2 2 2 Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 65kA 65kA 65kA 65kA 3 3 3 3 Ampere Rating 240 Vac Interrupting Rating 15 20 25 30 65kA 65kA 65kA 65kA $63.50 $63.50 $63.50 $63.50 GO-135B Wire Range1 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Product Number List Price TXQB2115 TXQB2120 TXQB2125 TXQB2130 $154.00 $154.00 $154.00 $154.00 TXQB 240 Vac, Internal Common Trip # of Poles List Price GO-135B Wire Range1 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Product Number List Price TXQB32015 TXQB32020 TXQB32025 TXQB32030 $263.00 $263.00 $263.00 $263.00 1Solid or stranded for 14-10 AWG. 2UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. MOLDED CASE CIRCUIT BREAKERS UL listed HACR (heating, air conditioning and refrigeration). 3 3-16 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Bolt-on Circuit Breakers 480Y/277V Class The TEY is a one-inch wide per pole, compact, "bolt-on" circuit breaker for use on grounded 480Y/277 Vac systems. The bolt-on mounting base, shown in the accessory table on page 3-34, makes the TEY suitable for various applications as a lug-lug breaker. TEY 1 pole 65kA @120 Vac; 14kA @120/240, 240, 277 Vac # of Poles 1 1 1 1 1 1 1 1 1 1 1 1 1 Ampere Rating Wire Range1 15 20 25 30 35 40 45 50 60 70 80 90 100 14-12 Cu/12-10 Al 14-12 Cu/12-10 Al 14-12 Cu/12-10 Al 14-10 Cu/14-10 Al 14-10 Cu/14-10 Al 14-10 Cu/14-10 Al 14-10 Cu/14-10 Al 14-10 Cu/14-10 Al 14-10 Cu/14-10 Al 4-1 Cu/2-1/0 Al 4-1 Cu/2-1/0 Al 4-1 Cu/2-1/0 Al 4-1 Cu/2-1/0 Al GO-135B Product Number TEY1152,3 TEY1202,3 TEY1253 TEY1303 TEY1353 TEY1403 TEY1453 TEY1503 TEY160 TEY170 TEY180 TEY190 TEY1100 List Price $72.00 $72.00 $72.00 $72.00 $72.00 $72.00 $72.00 $72.00 $72.00 $142.00 $142.00 $142.00 $142.00 1- 2- and 3-pole TEY breakers TEY 2 pole 65kA @120, 120/240, 240 Vac; 14kA @277 Vac 2 2 2 2 2 2 2 2 2 2 2 2 2 Ampere Rating Wire Range1 15 20 25 30 35 40 45 50 60 70 80 90 100 14-12 Cu/12-10 Al 14-12 Cu/12-10 Al 14-12 Cu/12-10 Al 14-10 Cu/14-10 Al 14-12 Cu/12-10 Al 14-10 Cu/14-10 Al 14-12 Cu/12-10 Al 14-10 Cu/14-10 Al 14-10 Cu/14-10 Al 4-1 Cu/2-1/0 Al 4-1 Cu/2-1/0 Al 4-1 Cu/2-1/0 Al 4-1 Cu/2-1/0 Al GO-135B Product Number TEY2153 TEY2203 TEY2253 TEY2303 TEY2353 TEY2403 TEY2453 TEY2503 TEY260 TEY270 TEY280 TEY290 TEY2100 TEY 3 pole 65kA @120, 120/240, 240 Vac; 14kA @277 Vac # of Poles 3 3 3 3 3 3 3 3 3 3 3 3 3 Ampere Rating 15 20 25 30 35 40 45 50 60 70 80 90 100 Wire Range1 List Price $216.00 $216.00 $216.00 $216.00 $216.00 $216.00 $216.00 $216.00 $216.00 $352.00 $352.00 $352.00 $352.00 MOLDED CASE CIRCUIT BREAKERS # of Poles GO-135B Product Number 14-12 Cu/12-10 Al 14-12 Cu/12-10 Al 14-12 Cu/12-10 Al 14-10 Cu/14-10 Al 14-12 Cu/12-10 Al 14-10 Cu/14-10 Al 14-12 Cu/12-10 Al 14-10 Cu/14-10 Al 14-10 Cu/14-10 Al 4-1 Cu/2-1/0 Al 4-1 Cu/2-1/0 Al 4-1 Cu/2-1/0 Al 4-1 Cu/2-1/0 Al TEY3153 TEY3203 TEY3253 TEY3303 TEY3353 TEY3403 TEY3453 TEY3503 TEY360 TEY370 TEY380 TEY390 TEY3100 3 List Price $316.00 $316.00 $316.00 $316.00 $316.00 $316.00 $316.00 $316.00 $316.00 $424.00 $424.00 $424.00 $424.00 1Solid or stranded for 14-10 AWG. 2Single-pole, 15 and 20 ampere breakers are also UL listed as switching duty breakers, suitable for switching 120, 240, or 277 Vac. 3UL listed HID (high intensity discharge). Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-17 Prices and data subject to change without notice Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Cable-in Cable-out (lug-lug) 240V Class TQC, THQC 120/240 Vac # of Poles 1 1 1 1 1 1 1 1 1 1 1 GO-135B Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 Product Number2 List Price 10 15 20 25 30 35 40 45 50 60 70 5kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 14-4 Cu/12-2 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al TQC1110WL THQC1115WL3,4 THQC1120WL3,4 THQC1125WL3 THQC1130WL3 THQC1135WL3 THQC1140WL3 THQC1145WL3 THQC1150WL3 THQC1160WL3 THQC1170WL $20.25 $20.25 $20.25 $20.25 $20.25 $20.25 $20.25 $20.25 $20.25 $20.25 $39.00 TQC, THQC 120/240 Vac, Internal Common Trip # of Poles 2 2 2 2 2 2 2 2 2 2 2 2 2 2 GO-135B Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 Product Number2 List Price 10 15 20 25 30 35 40 45 50 60 70 80 90 100 5kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 14-4 Cu/12-2 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al TQC2110WL THQC2115WL3 THQC2120WL3 THQC2125WL3 THQC2130WL3 THQC2135WL3 THQC2140WL3 THQC2145WL3 THQC2150WL3 THQC2160WL3 THQC2170WL THQC2180WL THQC2190WL THQC21100WL $46.50 $43.50 $43.50 $43.50 $43.50 $43.50 $43.50 $43.50 $43.50 $43.50 $83.50 $116.00 $116.00 $116.00 MOLDED CASE CIRCUIT BREAKERS TQC, THQC 240 Vac, Internal Common Trip 3 # of Poles 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 GO-135B Ampere Rating 240 Vac Interrupting Rating Wire Range1 Product Number2 List Price 10 15 20 25 30 35 40 45 50 60 70 80 90 100 10 15 20 25 30 35 40 45 50 60 70 80 90 100 5kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 5kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 14-4 Cu/12-2 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 14-4 Cu/12-2 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al TQC22010WL THQC22015WL THQC22020WL THQC22025WL THQC22030WL THQC22035WL THQC22040WL THQC22045WL THQC22050WL THQC22060WL THQC22070WL THQC22080WL THQC22090WL THQC22100WL TQC32010WL THQC32015WL THQC32020WL THQC32025WL THQC32030WL THQC32035WL THQC32040WL THQC32045WL THQC32050WL THQC32060WL THQC32070WL THQC32080WL THQC32090WL THQC32100WL $116.00 $116.00 $116.00 $116.00 $116.00 $116.00 $116.00 $116.00 $116.00 $116.00 $152.00 $173.00 $173.00 $173.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $178.00 $202.00 $202.00 $202.00 1Solid or stranded for 14-10 AWG. 2Use additional suffix "BP" (THQC32020WLBP) for bulk pack of 48 poles. Carton weight 20 lbs. 15-60 ampere breakers only. 3Suitable for mounting on standard 35mm DIN Rail. Refer to table on page 3-21 for termination options. 4UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. UL listed HACR (heating, air conditioning and refrigeration). Refer to Q Line accessories listed on pages 3-34 to 3-36. 3-18 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Cable-in Cable-out (lug-lug) 240V Class THQC 120 Vac, Ground Fault Circuit Interrupter GO-133 Ampere Rating 120 Vac Interrupting Rating Wire Range1 Product Number List Price 15 20 30 10kA 10kA 10kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al THQC1115GF2 THQC1120GF2 THQC1130GF2 $128.00 $128.00 $128.00 1 1 1 THHQC 120/240 Vac # of Poles GO-135B Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 Product Number3 List Price 15 20 25 30 35 40 45 50 60 70 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al THHQC1115WL4 THHQC1120WL4 THHQC1125WL4 THHQC1130WL4 THHQC1135WL4 THHQC1140WL4 THHQC1145WL4 THHQC1150WL4 THHQC1160WL4 THHQC1170WL $35.50 $35.50 $40.50 $40.50 $40.50 $40.50 $40.50 $40.50 $40.50 $52.00 1 1 1 1 1 1 1 1 1 1 THHQC 120/240 Vac, Internal Common Trip # of Poles GO-135B Ampere Rating 120/240 Vac Interrupting Rating Wire Range1 15 20 30 35 40 45 50 60 70 80 90 100 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 2 2 2 2 2 2 2 2 2 2 2 2 THQC1120GF Product Number3 List Price THHQC2115WL4 THHQC2120WL4 THHQC2130WL4 THHQC2135WL4 THHQC2140WL4 THHQC2145WL4 THHQC2150WL4 THHQC2160WL4 THHQC2170WL THHQC2180WL THHQC2190WL THHQC21100WL $83.50 $83.50 $83.50 $83.50 $83.50 $83.50 $83.50 $83.50 $129.00 $188.00 $188.00 $188.00 MOLDED CASE CIRCUIT BREAKERS # of Poles 1Solid or stranded for 14-10 AWG. 2Requires mounting plate. See page 3-34. Not suitable for use in GE column panels. 3Use additional suffix "BP" (THQC32020WLBP) for bulk pack of 48 poles. Carton weight 20 lbs. 15 - 60 amperes breakers only. 4Suitable for mounting on standard 35mm DIN Rail. UL listed HACR (heating, air conditioning and refrigeration). Use Q Line mounting accessories listed on pages 3-34 to 3-36. 3 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-19 Prices and data subject to change without notice Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Cable-in Cable-out (lug-lug) 240V Class THHQC 240 Vac, Internal Common Trip # of Poles 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 GO-135B Ampere Rating 240 Vac Interrupting Rating Wire Range1 15 20 25 30 35 40 45 50 60 70 80 90 100 15 20 25 30 35 40 45 50 60 70 80 90 100 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al 6-1/0 Cu/4-1/0 Al Product Number List Price THHQC22015WL THHQC22020WL THHQC22025WL THHQC22030WL THHQC22035WL THHQC22040WL THHQC22045WL THHQC22050WL THHQC22060WL THHQC22070WL THHQC22080WL THHQC22090WL THHQC22100WL THHQC32015WL THHQC32020WL THHQC32025WL THHQC32030WL THHQC32035WL THHQC32040WL THHQC32045WL THHQC32050WL THHQC32060WL THHQC32070WL THHQC32080WL THHQC32090WL THHQC32100WL $159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $200.00 $240.00 $240.00 $240.00 $216.00 $216.00 $216.00 $216.00 $216.00 $216.00 $216.00 $216.00 $216.00 $267.00 $314.00 $314.00 $314.00 TXQC 120/240 Vac MOLDED CASE CIRCUIT BREAKERS # of Poles 3 1 1 1 1 GO-135B Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 65kA 65kA 65kA 65kA Wire Range1 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Product Number List Price TXQC1115WL TXQC1120WL TXQC1125WL TXQC1130WL $63.50 $63.50 $63.50 $63.50 TXQC 120/240 Vac, Internal Common Trip # of Poles 2 2 2 2 Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 65kA 65kA 65kA 65kA GO-135B Wire Range1 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Product Number List Price TXQC2115WL TXQC2120WL TXQC2125WL TXQC2130WL $157.00 $157.00 $157.00 $157.00 TXQC 240 Vac, Internal Common Trip # of Poles 3 3 3 3 Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 65kA 65kA 65kA 65kA GO-138A Wire Range1 14-8 14-8 14-8 14-8 Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Cu/12-8 Al Product Number List Price TXQC32015WL TXQC32020WL TXQC32025WL TXQC32030WL $267.00 $267.00 $267.00 $267.00 1Solid or stranded for 14-10 AWG. UL listed HACR (heating, air conditioning and refrigeration). Use Q Line mounting accessories listed on pages 3-34 to 3-36. 3-20 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors DIN-Rail Mount 240V Class Product Features Multi-terminal Configuration Breakers --35 mm DIN rail mounting --Optional front/rear panel mounting kits-THQCFMK, page 3-34. --Optional load end terminal for up to (4) 0.25-inch quick connnects. Contact local GE sales office for ring terminal configurations-not DIN rail compatible. THQC, THHQC 120/240 Vac # of Poles 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 GO-135B Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 35 40 45 50 60 15 20 25 30 35 40 45 50 60 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA Product Number THQC1115LL1 THQC1120LL1 THQC1125LL THQC1130LL THQC1135LL THQC1140LL THQC1145LL THQC1150LL THQC1160LL THHQC1115LL THHQC1120LL THHQC1125LL THHQC1130LL THHQC1135LL THHQC1140LL THHQC1145LL THHQC1150LL THHQC1160LL List Price CC Suffix List Price Adder $17.25 $17.25 $17.25 $17.25 $17.25 $17.25 $17.25 $17.25 $17.25 $32.50 $32.50 $37.50 $37.50 $37.50 $37.50 $37.50 $37.50 $37.50 $4.00 X2 Suffix List Price Adder $1.50 15-60A UL Listed HACR (heating, air conditioning and refrigeration) # of Poles 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Ampere Rating 120/240 Vac Interrupting Rating 15 20 25 30 35 40 45 50 60 15 20 25 30 35 40 45 50 60 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA Product Number THQC2115LL1 THQC2120LL1 THQC2125LL THQC2130LL THQC2135LL THQC2140LL THQC2145LL THQC2150LL THQC2160LL THHQC2115LL THHQC2120LL THHQC2125LL THHQC2130LL THHQC2135LL THHQC2140LL THHQC2145LL THHQC2150LL THHQC2160LL GO-135B List Price CC Suffix List Price Adder $37.50 $37.50 $37.50 $37.50 $37.50 $37.50 $37.50 $37.50 $37.50 $77.50 $77.50 $77.50 $77.50 $77.50 $77.50 $77.50 $77.50 $77.50 $8.00 X2 Suffix List Price Adder MOLDED CASE CIRCUIT BREAKERS THQC, THHQC 120/240 Vac, Internal Common Trip $3.00 3 15-60A UL Listed HACR (heating, air conditioning and refrigeration) Terminal Configuration Suffix2 WL X2 LL CC None Terminal Selection Line Terminal TQAL3A TQAL3A N/A TQAL3A N/A Load Terminal THQEL3 N/A N/A THQECC THQEL3 Type Lug-Line only Lug-Load only Quick Connector-Load only GO-135B Wire Range 14-6 Cu/12-2 Al 14-2 Cu/12-2 Al (4) 14 Cu or (4) 12 Al Product Number TQAL3A THQEL3 THQECC List Price $1.50 $1.50 $2.50 115 and 20 ampere breakers UL listed as SWD (Switching Duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. 2Use additional suffix "BP" (THQC1120CCBP) for bulk pack of 48 poles. Must be ordered in multiples of 48 poles. Additional Q Line mounting accessories listed on pages 3-34 to 3-36. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-21 Prices and data subject to change without notice Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Cable-in Cable-out (lug-lug) 240V Class TQD 240 Vac, Internal Common Trip # of Poles 2 2 2 2 2 2 3 3 3 3 3 3 GO-135F Ampere Rating 240 Vac Interrupting Rating Product Number 1,2 List Price 100 125 150 175 200 225 100 125 150 175 200 225 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA TQD22100WL TQD22125WL TQD22150WL TQD22175WL TQD22200WL TQD22225WL TQD32100WL TQD32125WL TQD32150WL TQD32175WL TQD32200WL TQD32225WL $249.00 $249.00 $249.00 $249.00 $249.00 $249.00 $641.00 $641.00 $641.00 $641.00 $641.00 $641.00 TQD 240 Vac, Internal Common Trip with Factory Installed 120 Vac Shunt Trip 3 GO-135F # of Poles 3 3 3 3 3 Ampere Rating 240 Vac Interrupting Rating Product Number 1,2 List Price 125 150 175 200 225 10kA 10kA 10kA 10kA 10kA TQD32125ST1 TQD32150ST1 TQD32175ST1 TQD32200ST1 TQD32225ST1 $793.00 $793.00 $793.00 $793.00 $793.00 THQD 240 Vac, Internal Common Trip MOLDED CASE CIRCUIT BREAKERS # of Poles 3 2 2 2 2 2 2 3 3 3 3 3 3 GO-135F Ampere Rating 240 Vac Interrupting Rating Product Number 1,2 List Price 100 125 150 175 200 225 100 125 150 175 200 225 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA THQD22100WL THQD22125WL THQD22150WL THQD22175WL THQD22200WL THQD22225WL THQD32100WL THQD32125WL THQD32150WL THQD32175WL THQD32200WL THQD32225WL $568.00 $568.00 $568.00 $568.00 $568.00 $568.00 $907.00 $907.00 $907.00 $907.00 $907.00 $907.00 TJD 240 Vac, Internal Common Trip # of Poles 2 2 2 2 3 3 3 3 GO-135F Ampere Rating 240 Vac Interrupting Rating Product Number 1,2 List Price 250 300 350 400 250 300 350 400 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA TJD422250WL TJD422300WL TJD422350WL TJD422400WL TJD432250WL4 TJD432300WL4 TJD432350WL4 TJD432400WL4 $1494.00 $1494.00 $1494.00 $1494.00 $1802.00 $1802.00 $1802.00 $1802.00 1Refer to table on page 3-101 for lug and wire range data. 2Includes line and load lugs. For optional configurations see page 3-38. 3For additional shunt trip options see page 3-88 . 4TJD uses same accessories as J600 line. TJD not listed HACR. UL listed HACR (heating, air conditioning and refrigeration). TJD432300WL 3-22 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Molded Case Switches Note: Molded case switches may be used as main devices in panelboards and switchboards but cannot be used as subfeeds or branch breakers because they do not provide wire protection. Q Line and TEB molded case switches have a 10,000 ampere symmetrical short circuit withstand rating when protected by a fuse or circuit breaker rated 10,000 amperes IC or greater and whose ampere rating does not exceed the ampere rating of the switch. Plug-in TQL 120/240, Vac Internal Common Trip 2 2 GO-138 Ampere Rating 120/240 Vac Short Circuit Withstand Rating Wire Range1 60 100 10kA 10kA 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al Product Number List Price TQL21Y60 TQL21Y100 $51.00 $147.00 Plug-in TQL 240, Vac Internal Common Trip # of Poles 2 2 3 3 Ampere Rating 240 Vac Short Circuit Withstand Rating 60 100 60 100 10kA 10kA 10kA 10kA GO-138 Wire Range1 8-3 6-1/0 8-3 6-1/0 Cu/8-3 Al Cu/4-1/0 Al Cu/8-3 Al Cu/4-1/0 Al Product Number List Price TQL22Y60 TQL22Y100 TQL32Y60 TQL32Y100 $139.00 $235.00 $177.00 $266.00 Bolt-on TQB 120/240, Vac Internal Common Trip # of Poles 2 2 GO-138 Ampere Rating 120/240 Vac Short Circuit Withstand Rating Wire Range1 60 100 10kA 10kA 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al Product Number List Price TQB21Y60 TQB21Y100 $43.50 $113.00 Bolt-on TQB 240 Vac, Internal Common Trip # of Poles 2 2 3 3 Ampere Rating 240 Vac Short Circuit Withstand Rating 60 100 60 100 10kA 10kA 10kA 10kA GO-138 Wire Range1 8-3 6-1/0 8-3 6-1/0 Cu/8-3 Al Cu/4-1/0 Al Cu/8-3 Al Cu/4-1/0 Al Product Number List Price TQB22Y60 TQB22Y100 TQB32Y60 TQB32Y100 $113.00 $170.00 $139.00 $199.00 Cable In-Cable Out (Lug-Lug) TQC 120/240 Vac, Internal Common Trip GO-135B # of Poles Product Number List Price TQC21Y602 TQC21Y100 $43.50 $116.00 2 2 Ampere Rating 120/240 Vac Short Circuit Withstand Rating Wire Range1 60 100 10kA 10kA 8-3 Cu/8-3 Al 6-1/0 Cu/4-1/0 Al Cable In-Cable Out (Lug-Lug) TQC 240 Vac, Internal Common Trip # of Poles 2 2 3 3 Ampere Rating 240 Vac Short Circuit Withstand Rating 60 100 60 100 10kA 10kA 10kA 10kA Wire Range1 8-3 6-1/0 8-3 6-1/0 Cu/8-3 Al Cu/4-1/0 Al Cu/8-3 Al Cu/4-1/0 Al GO-135B Product Number List Price TQC22Y603 TQC22Y100 TQB32Y60 TQB32Y100 $116.00 $173.00 $139.00 $199.00 Cable In-Cable Out (Lug-Lug) TQD, TJD 240 Vac, Internal Common Trip # of Poles 2 3 2 3 MOLDED CASE CIRCUIT BREAKERS # of Poles Ampere Rating 240 Vac Short Circuit Withstand Rating Product Number 6 225 225 400 400 14kA 14kA 22kA 22kA TQD22Y225 TQD32Y2254 TJD422Y400 TJD432Y4005 3 GO-135F List Price $198.00 $559.00 $1169.00 $1509.00 1Solid or stranded for 14-10 AWG. 2Suitable for mounting on 35 mm DIN rail. 3For additional shunt trip offerings, see page 3-88. 4TQD32YT225 with dummy trip used for accessorized applications. 5TJD uses same accessories as J600 line. 6Refer to table on page 3-101 for lug and wire range data. Line and load lugs included in basic switch product number. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-23 Prices and data subject to change without notice Molded Case Circuit Breakers E2000 Miniature Circuit Breakers EP60 Series Applications --Residential --Commercial --Industrial Performance Thermal setting In (A) Rated Vac Un (V) Minimum operating voltage UB min (V) Tripping characteristics Selectivity class Mechanical/electrical endurance Tropicalisation acc. to IEC 60068-2 Terminal capacity flexible/rigid cable mm2 Poles Weight (g/pole) 0.5-63 240/415 12 B-C-D 3 20000/10000 95% RH at 55C 25-35 1, 2, 3, 4 120 Short-circuit Capacity Per UL 1077 & CSA 22.2 No. 235-1989 (File E151139) Poles 1 2 3, 4 Max. Voltage Rating AC DC 277 480Y/277 480Y/277 50 110 110 120 10 10 10 Short Circuit Rating kAIC RMS Symmetrical 120/240 277 480Y/277 - 10 10 6 6 6 6 6 6 kAIC DC 50 110 10 - - - 10 - MOLDED CASE CIRCUIT BREAKERS AC acc. to IEC 60898 3 Poles V Icn/Ics (kA) 1-4 230/400 6 Poles V Icu (kA)1 1 2,3,4 2,3,4 240 240 415 10 20 10 Poles V Icu/Ics (kA) 1 2 60 125 20 25 AC acc. to IEC 60947-2 Auxiliaries 1Ics = 75% Icu DC acc. to IEC 60947-2 Add-on Devices Approval/Marking --CE --cURus --CEBEC --KEMA EUR 3-24 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers E2000 Miniature Circuit Breakers EP60 Series Poles 1 2 3 4 Std. Pack 12 6 4 3 6 kAIC In (A) 0.5 1 2 3 4 5 6 10 13 15 16 20 25 30 32 40 50 60 63 0.5 1 2 3 4 5 6 10 13 15 16 20 25 30 32 40 50 60 63 0.5 1 2 3 4 5 6 10 13 15 16 20 25 30 32 40 50 60 63 0.5 1 2 3 4 5 6 10 13 15 16 20 25 30 32 40 50 60 63 Tripping Characteristic B (3-5X) C (5-10X) D (10-20X) Product No. Product No. Product No. - - - - - EP61ULB05 EP61ULB06 EP61ULB10 EP61ULB13 EP61ULB15 EP61ULB16 EP61ULB20 EP61ULB25 EP61ULB30 EP61ULB32 EP61ULB40 EP61ULB50 EP61ULB60 EP61ULB63 - - - - - EP62ULB05 EP62ULB06 EP62ULB10 EP62ULB13 EP62ULB15 EP62ULB16 EP62ULB20 EP62ULB25 EP62ULB30 EP62ULB32 EP62ULB40 EP62ULB50 EP62ULB60 EP62ULB63 - - - - - EP63ULB05 EP63ULB06 EP63ULB10 EP63ULB13 EP63ULB15 EP63ULB16 EP63ULB20 EP63ULB25 EP63ULB30 EP63ULB32 EP63ULB40 EP63ULB50 EP63ULB60 EP63ULB63 - - - - - EP64ULB05 EP64ULB06 EP64ULB10 EP64ULB13 EP64ULB15 EP64ULB16 EP64ULB20 EP64ULB25 EP64ULB30 EP64ULB32 EP64ULB40 EP64ULB50 EP64ULB60 EP64ULB63 EP61ULC0.5 EP61ULC01 EP61ULC02 EP61ULC03 EP61ULC04 EP61ULC05 EP61ULC06 EP61ULC10 EP61ULC13 EP61ULC15 EP61ULC16 EP61ULC20 EP61ULC25 EP61ULC30 EP61ULC32 EP61ULC40 EP61ULC50 EP61ULC60 EP61ULC63 EP62ULC0.5 EP62ULC01 EP62ULC02 EP62ULC03 EP62ULC04 EP62ULC05 EP62ULC06 EP62ULC10 EP62ULC13 EP62ULC15 EP62ULC16 EP62ULC20 EP62ULC25 EP62ULC30 EP62ULC32 EP62ULC40 EP62ULC50 EP62ULC60 EP62ULC63 EP63ULC0.5 EP63ULC01 EP63ULC02 EP63ULC03 EP63ULC04 EP63ULC05 EP63ULC06 EP63ULC10 EP63ULC13 EP63ULC15 EP63ULC16 EP63ULC20 EP63ULC25 EP63ULC30 EP63ULC32 EP63ULC40 EP63ULC50 EP63ULC60 EP63ULC63 EP64ULC0.5 EP64ULC01 EP64ULC02 EP64ULC03 EP64ULC04 EP64ULC05 EP64ULC06 EP64ULC10 EP64ULC13 EP64ULC15 EP64ULC16 EP64ULC20 EP64ULC25 EP64ULC30 EP64ULC32 EP64ULC40 EP64ULC50 EP64ULC60 EP64ULC63 EP61ULD0.5 EP61ULD01 EP61ULD02 EP61ULD03 EP61ULD04 EP61ULD05 EP61ULD06 EP61ULD10 EP61ULD13 EP61ULD15 EP61ULD16 EP61ULD20 EP61ULD25 EP61ULD30 EP61ULD32 EP61ULD40 EP61ULD50 EP61ULD60 EP61ULD63 EP62ULD0.5 EP62ULD01 EP62ULD02 EP62ULD03 EP62ULD04 EP62ULD05 EP62ULD06 EP62ULD10 EP62ULD13 EP62ULD15 EP62ULD16 EP62ULD20 EP62ULD25 EP62ULD30 EP62ULD32 EP62ULD40 EP62ULD50 EP62ULD60 EP62ULD63 EP63ULD0.5 EP63ULD01 EP63ULD02 EP63ULD03 EP63ULD04 EP63ULD05 EP63ULD06 EP63ULD10 EP63ULD13 EP63ULD15 EP63ULD16 EP63ULD20 EP63ULD25 EP63ULD30 EP63ULD32 EP63ULD40 EP63ULD50 EP63ULD60 EP63ULD63 EP64ULD0.5 EP64ULD01 EP64ULD02 EP64ULD03 EP64ULD04 EP64ULD05 EP64ULD06 EP64ULD10 EP64ULD13 EP64ULD15 EP64ULD16 EP64ULD20 EP64ULD25 EP64ULD30 EP64ULD32 EP64ULD40 EP64ULD50 EP64ULD60 EP64ULD63 GO-135VB List Price $78.00 $65.00 $65.00 $65.00 $65.00 $65.00 $65.00 $65.00 $65.00 $65.00 $65.00 $65.00 $65.00 $65.00 $65.00 $72.00 $76.00 $80.00 $80.00 $156.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $141.00 $145.00 $156.00 $164.00 $164.00 $230.00 $204.00 $204.00 $204.00 $204.00 $204.00 $204.00 $204.00 $204.00 $204.00 $204.00 $204.00 $204.00 $204.00 $204.00 $210.00 $219.00 $229.00 $229.00 $300.00 $269.00 $269.00 $269.00 $269.00 $269.00 $269.00 $269.00 $269.00 $269.00 $269.00 $269.00 $269.00 $269.00 $269.00 $272.00 $285.00 $293.00 $293.00 1 Pole 2 Pole MOLDED CASE CIRCUIT BREAKERS EP60 Series, 6 kAIC @277 or 480Y/277 Vac, Tripping Characteristics B-C-D 3 Pole 4 Pole Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-25 Prices and data subject to change without notice 3 Molded Case Circuit Breakers E2000 Miniature Circuit Breakers EP100 Series Applications --Residential --Commercial --Industrial Performance Thermal setting In (A) Rated Vac Un (V) Minimum operating voltage UB min (V) Tripping characteristics Selectivity class Mechanical/electrical endurance Tropicalisation acc. to IEC 60068-2 Terminal capacity flexible/rigid cable mm2 Poles Weight (g/pole) 0.5-63 240/415 12 B-C-D 3 20000/10000 95% RH at 55C 25-35 1, 2, 3, 4 120 Short-circuit Capacity Per UL 1077 & CSA 22.2 No. 235-1989 (File E151139) Poles 1 2 3, 4 Max. Voltage Rating AC DC 277 480Y/277 480Y/277 50 110 110 120 10 10 10 Short Circuit Rating kAIC RMS Symmetrical 120/240 277 480Y/277 - 10 10 10 10 10 - - 10 kAIC DC 50 110 10 - - - 10 - AC acc. to IEC 60898 Poles V Icn (kA)1 1-4 230/400 10 MOLDED CASE CIRCUIT BREAKERS 1Ics = 75% Icu 3 Auxiliaries AC acc. to IEC 60947-2 Poles V Icu (kA)2 1 2,3,4 2,3,4 240 240 415 15 30 15 2Ics = 50% Icu Add-on Devices DC acc. to IEC 60947-2 Poles V Icu/Ics (kA) 1 2 60 125 25 30 Approval/Marking --CE --cURus --CEBEC --KEMA EUR 3-26 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers E2000 Miniature Circuit Breakers EP100 Series Poles 1 2 3 4 Std. Pack 12 6 4 3 6 kAIC In (A) 0.5 1 2 3 4 5 6 10 13 15 16 20 25 30 32 40 50 60 63 0.5 1 2 3 4 5 6 10 13 15 16 20 25 30 32 40 50 60 63 0.5 1 2 3 4 5 6 10 13 15 16 20 25 30 32 40 50 60 63 0.5 1 2 3 4 5 6 10 13 15 16 20 25 30 32 40 50 60 63 Tripping Characteristic B (3-5X) C (5-10X) D (10-20X) Product No. Product No. Product No. - - - - - EP101ULB05 EP101ULB06 EP101ULB10 EP101ULB13 EP101ULB15 EP101ULB16 EP101ULB20 EP101ULB25 EP101ULB30 EP101ULB32 EP101ULB40 EP101ULB50 EP101ULB60 EP101ULB63 - - - - - EP102ULB05 EP102ULB06 EP102ULB10 EP102ULB13 EP102ULB15 EP102ULB16 EP102ULB20 EP102ULB25 EP102ULB30 EP102ULB32 EP102ULB40 EP102ULB50 EP102ULB60 EP102ULB63 - - - - - EP103ULB05 EP103ULB06 EP103ULB10 EP103ULB13 EP103ULB15 EP103ULB16 EP103ULB20 EP103ULB25 EP103ULB30 EP103ULB32 EP103ULB40 EP103ULB50 EP103ULB60 EP103ULB63 - - - - - EP104ULB05 EP104ULB06 EP104ULB10 EP104ULB13 EP104ULB15 EP104ULB16 EP104ULB20 EP104ULB25 EP104ULB30 EP104ULB32 EP104ULB40 EP104ULB50 EP104ULB60 EP104ULB63 EP101ULC0.5 EP101ULC01 EP101ULC02 EP101ULC03 EP101ULC04 EP101ULC05 EP101ULC06 EP101ULC10 EP101ULC13 EP101ULC15 EP101ULC16 EP101ULC20 EP101ULC25 EP101ULC30 EP101ULC32 EP101ULC40 EP101ULC50 EP101ULC60 EP101ULC63 EP102ULC0.5 EP102ULC01 EP102ULC02 EP102ULC03 EP102ULC04 EP102ULC05 EP102ULC06 EP102ULC10 EP102ULC13 EP102ULC15 EP102ULC16 EP102ULC20 EP102ULC25 EP102ULC30 EP102ULC32 EP102ULC40 EP102ULC50 EP102ULC60 EP102ULC63 EP103ULC0.5 EP103ULC01 EP103ULC02 EP103ULC03 EP103ULC04 EP103ULC05 EP103ULC06 EP103ULC10 EP103ULC13 EP103ULC15 EP103ULC16 EP103ULC20 EP103ULC25 EP103ULC30 EP103ULC32 EP103ULC40 EP103ULC50 EP103ULC60 EP103ULC63 EP104ULC0.5 EP104ULC01 EP104ULC02 EP104ULC03 EP104ULC04 EP104ULC05 EP104ULC06 EP104ULC10 EP104ULC13 EP104ULC15 EP104ULC16 EP104ULC20 EP104ULC25 EP104ULC30 EP104ULC32 EP104ULC40 EP104ULC50 EP104ULC60 EP104ULC63 EP101ULD0.5 EP101ULD01 EP101ULD02 EP101ULD03 EP101ULD04 EP101ULD05 EP101ULD06 EP101ULD10 EP101ULD13 EP101ULD15 EP101ULD16 EP101ULD20 EP101ULD25 EP101ULD30 EP101ULD32 EP101ULD40 EP101ULD50 EP101ULD60 EP101ULD63 EP102ULD0.5 EP102ULD01 EP102ULD02 EP102ULD03 EP102ULD04 EP102ULD05 EP102ULD06 EP102ULD10 EP102ULD13 EP102ULD15 EP102ULD16 EP102ULD20 EP102ULD25 EP102ULD30 EP102ULD32 EP102ULD40 EP102ULD50 EP102ULD60 EP102ULD63 EP103ULD0.5 EP103ULD01 EP103ULD02 EP103ULD03 EP103ULD04 EP103ULD05 EP103ULD06 EP103ULD10 EP103ULD13 EP103ULD15 EP103ULD16 EP103ULD20 EP103ULD25 EP103ULD30 EP103ULD32 EP103ULD40 EP103ULD50 EP103ULD60 EP103ULD63 EP104ULD0.5 EP104ULD01 EP104ULD02 EP104ULD03 EP104ULD04 EP104ULD05 EP104ULD06 EP104ULD10 EP104ULD13 EP104ULD15 EP104ULD16 EP104ULD20 EP104ULD25 EP104ULD30 EP104ULD32 EP104ULD40 EP104ULD50 EP104ULD60 EP104ULD63 GO-135VB List Price $116.00 $97.00 $97.00 $97.00 $97.00 $97.00 $97.00 $97.00 $97.00 $97.00 $97.00 $97.00 $97.00 $97.00 $97.00 $107.00 $113.00 $119.00 $119.00 $233.00 $210.00 $210.00 $210.00 $210.00 $210.00 $210.00 $210.00 $210.00 $210.00 $210.00 $210.00 $210.00 $210.00 $210.00 $216.00 $233.00 $245.00 $245.00 $343.00 $304.00 $304.00 $304.00 $304.00 $304.00 $304.00 $304.00 $304.00 $304.00 $304.00 $304.00 $304.00 $304.00 $304.00 $314.00 $327.00 $342.00 $342.00 $448.00 $401.00 $401.00 $401.00 $401.00 $401.00 $401.00 $401.00 $401.00 $401.00 $401.00 $401.00 $401.00 $401.00 $401.00 $407.00 $425.00 $437.00 $437.00 1 Pole 2 Pole MOLDED CASE CIRCUIT BREAKERS EP100 Series, 10 kAIC @120 or 120/240 Vac, Tripping Characteristics B-C-D 3 Pole 4 Pole Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-27 Prices and data subject to change without notice 3 Molded Case Circuit Breakers E2000 Miniature Circuit Breakers EP100 UC Series1 Applications --Industrial Performance Thermal setting In (A) Rated Vac Un (V) Minimum operating voltage UB min (V) Tripping characteristics Selectivity class Mechanical/electrical endurance Tropicalisation acc. to IEC 60068-2 Terminal capacity flexible/rigid cable mm2 Poles Weight (g/pole) 0.5-63 240/400; 230/440 12 B-C 3 20000/10000 95% RH at 55C 25-35 1, 2 120 Short-circuit Capacity AC acc. to IEC 60898 Poles V Icn/Ics (kA) 125 DC 220 DC 230/400 AC 250 DC 440 DC 400 AC 10 6 6 10 6 6 Poles V Icu/Ics (kA) 1, 2 240 AC 10 1 2 AC acc. to IEC 60947-2 MOLDED CASE CIRCUIT BREAKERS Approval/Marking --IEC 60898-2, DIN VDE 0641 --CE Auxiliaries 1Not UL approved Add-on Devices 3 3-28 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers E2000 Miniature Circuit Breakers EP100 UC Series1 EP100 UC Series, 6 kAIC @400 or 230/400 Vac, Tripping Characteristics B-C Poles Std. Pack 1 2 12 6 6 kAIC In (A) 0.5 1 2 4 6 10 16 20 25 32 40 50 63 0.5 1 2 4 6 10 16 20 25 32 40 50 63 Tripping Characteristic B (3-5X) C (5-10X) Product No. Product No. - - - - EP101UCB06 EP101UCB10 EP101UCB16 EP101UCB20 EP101UCB25 EP101UCB32 EP101UCB40 EP101UCB50 EP10s1UCB63 - - - - EP102UCB06 EP102UCB10 EP102UCB16 EP102UCB20 EP102UCB25 EP102UCB32 EP102UCB40 EP102UCB50 EP102UCB63 GO-135VB List Price EP101UCC0.5 EP101UCC01 EP101UCC02 EP101UCC04 EP101UCC06 EP101UCC10 EP101UCC16 EP101UCC20 EP101UCC25 EP101UCC32 EP101UCC40 EP101UCC50 EP101UCC63 EP102UCC0.5 EP102UCC01 EP102UCC02 EP102UCC04 EP102UCC06 EP102UCC10 EP102UCC16 EP102UCC20 EP102UCC25 EP102UCC32 EP102UCC40 EP102UCC50 EP102UCC63 $145.00 $121.00 $121.00 $121.00 $121.00 $121.00 $121.00 $121.00 $121.00 $121.00 $121.00 $145.00 $163.00 $320.00 $267.00 $267.00 $267.00 $267.00 $267.00 $267.00 $267.00 $267.00 $267.00 $267.00 $319.00 $360.00 1 Pole 1Not UL approved MOLDED CASE CIRCUIT BREAKERS 2 Pole 3 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-29 Prices and data subject to change without notice Molded Case Circuit Breakers E2000 Miniature Circuit Breakers Series CA Auxiliary Switch and Bell Alarm Applications --Commercial --Industrial Features --Common for all MCBs --Can be coupled on both sides of MCBs --Gold contact version available for low current and low voltage applications --Stack up to four CA on left and right sides --Permits the pass-through of busbars, pin and fork, top and bottom, by changing the position of the base of the auxiliaries Performance Change-over contacts Rate current In (A) Rated voltage AC Un (V) Electrical endurance Terminal capacity flexible/rigid cable (mm2) Weight (g) 1 Form C 5 240 10000 2.5 70 Functions Auxiliary contacts are units to be added on to protection devices. They allow information about the status of the protection device to be monitored from a distance. Coupling MOLDED CASE CIRCUIT BREAKERS Auxiliary contact CA H (function H) reports the OPEN/CLOSED status. 3 CA S/H or CA S/H G act as either an auxiliary contact (function H) or a signal contact (function S). The user can set the function at the time of installation. When used as a signal contact, it reports information about the automatic tripping of the protection devices. A test button on the front simulates functions H or S. There are also a reset button for the contacts (function S) and a tripping signal (function S). Busbar pass-through Approval/Marking --CE --cURus --CEBEC --KEMA EUR Stack-on Series CA GO-135VB Function Std. Pack Product No. List Price H S/H S/H (gold contacts) 1 1 1 CA H CA S/H CA S/H G $47.00 $59.00 $59.00 1/2 mod. H 3-30 Prices and data subject to change without notice BuyLog Catalog S www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers E2000 Miniature Circuit Breakers Series CB Auxiliary Switch and Bell Alarm Applications --Commercial --Industrial Features --Common for all MCBs --Can be coupled on both sides of MCBs --There are two change-over contacts - the upper one features changeable function S/H --CB SH/HH-R couples to the right side of the protection devices; CB SH/HH-L couple to the left --No stack-on possibilities (only one auxiliary) --No busbar pass-through facilities Performance Change-over contacts Rate current In (A) Rated voltage AC Un (V) Electrical endurance Terminal capacity flexible/rigid cable (mm2) Weight (g) 2 Form C 5 240 10000 2.5 80 Functions The top auxiliary contact can act as either an auxiliary contact (function H) or a signal contact (function S). The user can set the function at the time of installation. When used as a signal contact, it reports information about the automatic tripping of the protection devices. A test button on the front simulates functions H or S. There are also a reset button for the contacts (function S) and a tripping signal (function S). MOLDED CASE CIRCUIT BREAKERS The bottom auxiliary contact (function H) reports the OPEN/CLOSED status. Coupling right 3 Approval/Marking --cURus Coupling left Series CB GO-135VB Function Coupling Std. Pack Product No. List Price SH/HH SH/HH Right Left 1 1 CB SH/HH-R CB SH/HH-R $87.00 $87.00 1/2 mod. H S Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-31 Prices and data subject to change without notice Molded Case Circuit Breakers E2000 Miniature Circuit Breakers Shunt Trip and Undervoltage Release Applications --Commercial --Industrial Features --Common devices for all miniature circuit breakers --Can be coupled on both sides of MCBs --Permits pass-through of busbars, pin and fork, at top or bottom terminals --Stack up to four modules on left and right sides Approval/Marking --CURUS --IEC 947-2 Shunt Trip Tele L The Tele L allows remote switching of any miniature circuit breaker by means of push buttons or any other automatic management processor. A built-in contact, in series with the coil, prevents burnout damage if the voltage remains. Shunt Trip Tele L Performance MOLDED CASE CIRCUIT BREAKERS Rated voltage (V) (V) Tripping time (ms) Electrical endurance Terminal capacity flexible/rigid cable (mm2) Weight (g) 3 110/415, 110/125 DC 24/60, 24/48 DC <10 10000 2.5 125 Shunt Trip Tele L Coupling GO-135VB Voltage Poles 1 Std. Pack AC DC Product No. List Price 1 24-60 V 110-415 V 24-48 V 110-125 V TELE L-1 TELE L-2 $90.00 $90.00 Busbar pass-through Undervoltage Release Tele U The Tele U releases the main miniature circuit breaker in case the power supply drops below 0.5xUn. Time delay is adjustable up to 300 ms. Stack-on Undervoltage Release Tele U Performance Rated voltage AC UN (V) Rated voltage DC/AC UN (V) Tripping voltage (V) Resetting voltage (V) Tripping time (ms) Electrical endurance Terminal capacity flexible/rigid cable (mm2) Weight (g) 240 12, 24, 48 DC/AC 0.5xUN 10% >0.5xUN 10% Adjustable 1-300 2000 2.5 125 Undervoltage Release Tele U Poles 1 Std. Pack Voltage 1 AC 230V AC/DC 12V AC/DC 24V AC/DC 48V GO-135VB Product No. TELE TELE TELE TELE U-230 U-12 U-24 U-48 List Price $128.00 $128.00 $128.00 $128.00 Shunt Trip Tele L 3-32 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Undervoltage Release Tele L Rev. 12/04 Molded Case Circuit Breakers E2000 Miniature Circuit Breakers Technical Data Standards Tripping characteristics Nominal current Calibration temperature Number of poles (# mod) Neutral pole protected Nominal voltage Un EP100 EP100 UC C/RH C C mm2 mm2 UL1077, EN60947-2 B, C, D B: 6-63, C/D: 0.5-63 30 1/1+N/2/3/4 yes 240/415 415 415 48 110 50/60 DC:magn.trip + 40% DC:magn.trip + 50% 250/440; 53/120 12; 12 3 yes 500 440 6 10000 2.5 3g 10000 20000 A any yes IP20/IP40 V2 +55%C/95% RH -25/+55 -55/+55 1/35 0.75/25 UL1077, EN60947-2 B, C, D B: 6-63, C/D: 0.5-63 30 1/1+N/2/3/4 yes 240/415 415 415 48 110 50/60 DC:magn.trip + 40% 400:magn.trip + 50% 250/440; 53/120 12; 12 3 yes 500 440 6 10000 2.5 3g 10000 20000 A any yes IP20/IP40 V2 +55%C/95% RH -25/+55 -55/+55 1/35 0.75/25 IEC EN70898-2 B, C B: 6-63, C: 0.5-63 30 1/2 - 240/415 415 415 220 440 50/60 DC:magn.trip + 40% 400:magn.trip + 50% 250/440; 250/440 12; 12 3 yes 500 440 6 10000 2.5 3g 1000 20000 A any yes IP20/IP40 V2 +55%C/95% RH -25/+55 -55/+55 1/35 0.75/25 mm2 mm2 1/35 0.75/25 1/35 0.75/25 1/35 0.75/25 Nm 4.5 yes yes yes yes/yes -/yes yes 18 120 12 KEMA yes 4.5 yes yes yes yes/yes -/yes yes 18 120 12 KEMA yes 4.5 yes yes yes yes/yes -/yes yes 18 125 12 yes A C AC DC 1P 2P 3P/3P+N/4P 1P (1) 2P (in series) (1) Frequency Maximum service voltage Ubmax between two wires Minimum service voltage Ubmin Selectivity class (IEC 60898) Isolator application IEC 60947-2 Rated insulation voltage - Pollution Degree 2 Rated insulation voltage - Pollution Degree 3 Impulse withstand test voltage Insulation resistance Dielectric rigidity Vibrations resistance (in x,y,z direction) (IEC 77/16,3) Endurance - electrical at Un, In Endurance - mechanical Utilization category (IEC 60947 - 2) Mounting position Incoming top or bottom Protection degree (outside/inside enclosure with door) Self extinguish degree (according to UL94) Tropicalisation (according to IEC 60068-2/DIN 40046) Operating temperature Storage temperature Terminal capacity - Rigid cable min/max (top) Terminal capacity - Flexible cable min*/max (top) (*Flexible cable 0.75/1/1.5 mm2 with cable lug) Terminal capacity - Rigid cable min/max (bottom) Terminal Capacity - Flexible cable min*/max (bottom) (*Flexible cable 0.75/1/1.5 mm2 with cable lug) Torque Add-on services - Auxiliary contacts Add-on services - Tele U Add-on services - Tele L Busbar systems - pin (top/bottom) (non-UL) Busbar systems - fork (top/bottom) (non-UL) Accessories Dimensions, weights, packaging V V V Vdc Vdc Hz Hz Hz V V V V Kv Mohm Kv (HxDxW) 86x68xW Weight/mod Package Approvals CE-marking mm/mod g mod. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-33 Prices and data subject to change without notice MOLDED CASE CIRCUIT BREAKERS Series EP60 3 Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Accessories Terminals (Lugs) for Q Line Circuit Breakers Ampere Rating 15-60 15-60 15-60 GO-135B Termination Type Wire Range (Cu/Al) Lug (line only) Lug (load only) Quick connector (load only) 14-6/12-2 14-2/12-2 (4) 14/(4) 12 Product Number List Price TQAL3A THQEL3 THQECC $1.50 $1.50 $2.50 Internal Accessories for TEY (2- and 3-pole breaker only) Factory Installed Only Auxiliary Switch, Single-Pole (6A at 240 Vac,1/2A at 125 Vdc, 1/4A at 250 Vdc) GO-135B Add suffix to Breaker Product Number List Price Adder AS1A AS1B ASAB ST12 $148.00 $148.00 $288.00 $358.00 "A" switch (normally open) "B" switch (normally closed) "AB" switch (both) Shunt Trip 120-277 Vac control voltage Mounting Accessories for THQB, THQC, TEY MOLDED CASE CIRCUIT BREAKERS Product Type Ampere Rating GO-135B # of Poles Used With Frame Bolt-on Mounting Base 3 TEY3B Back Mounting Plates Screw Type Back Mounting Plates Screw Type Back Mounting Plates Screw Type Back Mounting Plates Screw Type Front-mounting Plates Front-mounting Plates Front-mounting Plates Front-mounting Plates Front/Rear Mounting Clips DIN rail clips 1 TEY THQB THQC TQCBMPA1 $8.30 2 THQC TQCBMPA2 $9.80 3 THQC TQCBMPA3 $12.00 10 THQC TQCBMPA10 $32.00 15-60A 1 2 3 4 1&2 THQC THQC THQC THQC THQC TQCFMP11 TQCFMP21 TQCFMP31 TQCFMP41 THQCFMK2 $8.30 $9.80 $12.00 $14.00 $48.00 15-60A 1&2 THQC THQCDIN2 $24.00 Product Number List Price $31.50 Load Lug THQEL3 1Not UL listed. 2Price is per pack. Mounting Accessories for THQC, THQC-GF, GFEP, AF 3 Quick Connector THQECC Product Type GO-133 # of Poles Used With Frame Product Number List Price 1 THQC, THQC-GF TQCGFBMPA1 $6.10 2 THQC, THQC-GF TQCGFBMPA2 $7.60 3 THQC, THQC-GF TQCGFBMPA3 $9.10 10 THQC, THQC-GF TQCGFBMPA10 $25.00 Snap In Back Mounting Plates Snap In Back Mounting Plates Snap In Back Mounting Plates Snap In Back Mounting Plates Mounting Accessories for TQL Product Type Plug-in Plug-in Plug-in Plug-in Mounting Mounting Mounting Mounting Base Base Base Base Mounting Kit THQCFMK G0-134A Ampere Rating # of Poles Used With Frame Product Number List Price 70 amp 70 amp 100 amp 100 amp 2 3 3 2 TQL TQL TQL TQL 571B595DDG1 571B595DDG2 565B837G1 565B837G2 $23.75 $32.00 $38.00 $23.75 3-34 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Accessories Handle Locking Devices Product Number THL103 $6.501 TQPL $5.501 TEY TEYLD1 $5.00 E150 Line TLD3 $5.00 THLC2, 4 F225 Line SF250 SE150 TFKLD1 $6.00 SBD1 $4.702 Handle Locking Devices Product Type TQD TQDL TQB TQL THQP Handle Locks - Padlocking Product Number List Price TQDPLD13 TQDLPDL13 THP100 $20.75 $17.75 $6.501 TQPPL Handle Locking Devices Handle Locks - Padlocking Handle Locks - Padlocking Handle Locks - Padlocking Handle Locks - Padlocking Handle Locks - Padlocking Handle Locks - Padlocking Handle Locks - Padlocking Handle Locks - Padlocking Handle Locks - Padlocking Handle Locks - Padlocking Handle Locks - Padlocking $5.75 GO-135B Used With Frame Product Number TQC TEY E150 TB1 THLC1 F225 THLC2 THLC4 TLB4 J600 Line K1200 Line List Price TQPLD13 TEYPLD1 TEFPLD1 $4.70 $9.00 $8.00 TLC1PLD1 TFKPLD1 TLC4PLD1 $17.00 $4.00 $22.00 TJKPLD1 TKMPLD1 $8.00 $28.50 Product Number List Price Handle Locking Devices Product Type THL103 GO-137A Used With Frame Handle Locks - Padlocking Handle Locks - Padlocking Handle Locks - Padlocking Product Type List Price TQC TQB TQL THQP Handle Locks Non Padlocking Handle Locks Non Padlocking Handle Locks Non Padlocking Handle Locks Non Padlocking Handle Locks Non Padlocking Handle Locks Non Padlocking GO-135B Used With Frame THP100 MOLDED CASE CIRCUIT BREAKERS Product Type GO-135S Used With Frame SF250 SE150 SG600 SK1200 SEPLD3 $8.70 SGPLD3 SKPLD3 $15.00 $28.50 3 1GO-137A. 2GO-135S. 3Suitable for circuit breakers used in group mounted panelboard construction only except for J600, K1200, SE150/SE250, SG600 and SK1200 which screw down to face of breaker. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-35 Prices and data subject to change without notice Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Accessories Handle Locking and Handle Extension Devices EUSERC Approved -- Factory Installed Only Product Type Handle Handle Handle Handle Handle Handle Handle Handle Locks Locks Locks Locks Locks Locks Locks Locks Used With Frame - Padlocking Padlocking Padlocking Padlocking Padlocking Padlocking Padlocking Padlocking Product Number TQDPLD2 TEDPLD2 TJKPLD2 THLC1PLD2 THLC4PLD2 SEFPLD2 SGPLD2 SKPLD2 GO-135B List Price $32.00 $32.00 $48.00 $48.00 $48.00 $32.001,2 $48.001 $60.001 THT1 Handle Locking and Handle Extension Devices Product Type Used With Frame Snap-on Handle Tie - open Snap-on Handle Tie - solid Snap-on Handle Tie - solid, indicating Snap-on Handle Tie - trip indicating Handle Extension - replacement GO-137A Product Number THT23 THT104 THT1 $2.30 $2.30 $2.30 TQC TQHT1 $2.30 SK1200 SKHDLEXT Used With Frame Product Number Breaker Mounting Screw Kits Product Type Breaker Mounting Screw Kits List Price THQP TQL THQP $96.501 GO-135B THQB TQBS14 List Price $6.00 1GO-135S. THT104 2Field Installable 3For 2 THQPs separated by 2 side-by-side THQPs. MOLDED CASE CIRCUIT BREAKERS 4Price is per screw. Packaged in quantities of 24. Must be ordered in multiples of 24. 3 TQHT1 THT2 3-36 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers Spectra RMS, Spectra RMS with MicroVersaTrip Plus Trip Units, Spectra RMS with MicroVersaTrip PM Trip Units, Thermal Magnetic and J/K with MicroVersaTrip RMS-9 and Power+ 4 Trip Units Spectra RMS --Circuit Breakers Determine the required breaker frame, IC rating, and load requirements. Select frame, trip unit (rating plug), and lug, if required, product numbers from the tables on pages 3-48 to 3-58. For Spectra breakers with MicroVersaTrip Plus Trip Units or MicroVersaTrip PM Trip Units refer to pages 3-59 through 3-61. Select field-mounted internal accessory product numbers, if required, on pages 3-83 and 3-84. Select fieldmounted external accessory product numbers, if required, on pages 3-92 through 3-104. Order as separate items. --Mag-Break Motor Circuit Protectors Determine the required frame and ampere requirements. Select frame, trip unit (rating plug), and lug, if required, product numbers from the table on pages 3-73 through 3-75. Select accessories as noted above for circuit breakers. The same accessories are used with both circuit breakers and motor circuit protectors. Order as separate items. --Molded Case Switches Determine the required frame and ampere requirements. Select frame and lug, if required, product numbers from the table on page 3-72. Rating plugs are not used. Select accessories as noted above for circuit breakers. Internal accessories do not require dummy trips. The same accessories are used with both circuit breakers and molded case switches. Order as separate items. Unless otherwise noted, all circuit breakers are UL listed in File E-11592. Molded case switches are UL listed in File E-57546. Field-Installable Internal Accessories are UL listed in File E-57253. Distribution Cable Accessories for MicroVersaTrip Plus Trip Units and MicroVersaTrip PM Trip Units are UL listed in File E-57253. E 150 Line --Thermal Magnetic Circuit Breakers --Magnetic Circuit Breakers --Molded Case Switches The product numbers as shown in the following pages include the complete breaker or switch. All devices listed come with Cu/Al line and load lugs. If line lugs are not required on a breaker, eliminate "WL" from product number; for molded case switches see page 3-38. Unless otherwise noted, all circuit breakers are UL listed in File E-11592. Molded case switches are UL listed in File E-57546. F 225 Line --Thermal Magnetic Circuit Breakers --Magnetic Circuit Breakers --Molded Case Switches These breakers are available with either noninterchangeable trips (designated Type TFJ) or interchangeable trips (designated Types TFK/THFK). When ordering Type TFJ, product number includes complete breaker, trip unit, CU/Al line and load lugs factory assembled. If line lugs are not required on a breaker, eliminate "WL" from product number, and subtract price of line lugs from price of complete breaker. If interchangeable trip (Types TFK/THFK) is required order one of two ways. "Complete circuit breaker" price includes frame, trip, Cu/Al line and load lugs. Units will be shipped unassembled unless specified on order "must be factory assembled." If line lugs are not required on a breaker, eliminate "WL" from product number, and subtract price of line lugs from price of complete breaker. To order the frame, trip, and lugs separately, select the required components from table. Magnetic breakers must be ordered as components. A complete breaker consists of frame, trip unit, one line lug per pole and one load lug per pole. Price of "Complete Circuit Breaker" vs. ordering frame, trip, and line and load lugs separately is the same. Molded case switches can also be ordered as complete units (designated TFK---Y) or as separate components. They are UL listed only as complete units. To indicate required lugs, see page 3-38. Unless otherwise noted, all circuit breakers are UL listed in File E-11592. Molded case switches are UL listed in File E-57546. J 600 Line --Thermal Magnetic Circuit Breakers --Magnetic Circuit Breakers --Molded Case Switches These breakers are available with either noninterchangeable trip (designated Type TJJ) or interchangeable trip (designated Type TJK and THJK). Type TJJ product numbers include frame, trip, Cu/Al line, and load lugs factory assembled. If line lugs are not required on the breaker, eliminate "WL" from product number, and subtract price of line lugs from price of complete breaker. TJK breakers are available in two frames, 400 ampere frame (125 to 400 amperes) and 600 ampere frame (250 to 600 amperes). Trip units are not interchangeable between frames. "Complete Circuit Breaker" price includes frame, trip unit, Cu/Al line, and load lugs. Unit will be shipped unassembled unless order specifies "must be factory assembled." If line lugs are not required, eliminate "WL" from product number and subtract price of line lugs from price of complete breaker. To order the frame, trip, and lugs separately, select the required components from table. Magnetic breakers must be ordered as components. A complete breaker consists of frame, trip, and one line and one load lug per pole. Price of ordering "Complete Circuit Breaker" vs. frame, trip, and line and load lugs separately is the same. Molded case switches can also be ordered as complete units (designated Type TJK---Y) or as separate components. They are UL listed only as complete units. To indicate required lugs, see page 3-38. Unless otherwise noted, all circuit breakers are UL listed in File E-11592. Molded case switches are UL listed in File E-57546. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-37 Prices and data subject to change without notice MOLDED CASE CIRCUIT BREAKERS How to Order 3 Molded Case Circuit Breakers Industrial Case Circuit Breakers K 1200 Line Mag-Break Line --Magnetic only circuit breakers (motor circuit protectors) --Thermal Magnetic Circuit Breakers --Magnetic Breakers --Molded Case Switches These breakers are available only with interchangeable trip units. Two frame sizes are available, the 800 ampere frame (300 to 800 amperes) and the 1200 ampere frame (600 to 1200 amperes). Trip units are not interchangeable between frames. "Complete Circuit Breaker" price includes frame, trip, Cu/Al line, and load lugs. Units will be shipped unassembled unless specified "must be factory assembled." If line lugs are not required on the breaker, eliminate "WL" from product number and subtract price of line lugs. To order the frame, trip, and lugs separately, select the required components from table. Magnetic circuit breakers must be ordered as components. A complete breaker consists of frame, trip and one line and one load lug per pole. Price of ordering "Complete Circuit Breaker" vs. frame, trip, and line and load lugs separately is the same. Molded case switches can also be ordered as complete units (designated Type TKMA---Y) or as separate components. They are UL listed only as complete units. To indicate required lugs, see the table below. MOLDED CASE CIRCUIT BREAKERS Unless otherwise noted, all circuit breakers are UL listed in File E-11592. Molded case switches are UL listed in File E-57546. 3 R Frame--1000/1600/2000 Ampere Molded Case Circuit Breakers --Solid-state MicroVersaTrip Plus or MicroVersaTrip PM Trip Unit --Interchangeable trip unit via rating plugs --65 and 100 kA ratings available --Standard and 100% rated versions --Uses standard Power Break accessories --Stationary/manual only Circuit Breakers with MicroVersaTrip Trip Units --Solid-state construction with MicroVersaTrip Plus digital rms sensing microprocessor trip units. --Available in J and K frame construction with ampere ratings from 60-1200A. For ordering information see pages 3-80 through 3-82. UL listed, File E-11592. All breakers are UL listed in File E-11592. Tri-Break Line --Integrally Fused Thermal Magnetic Circuit Breakers --Integrally Fused Magnetic Circuit Breakers --Integrally Fused Molded Case Switches These breakers are available in four types. Type TB1 (15-100 amperes) product numbers include frame, trip, line and load lugs, and current limiters all factory assembled. Types TB4 (125 to 400 amperes), TB6 (300 to 600 amperes) and TB8 (600 to 800 amperes) include frame, trip and limiters, factory assembled, but do not include line or load lugs. If line and load lugs are required, order separately. Unless otherwise noted, TB1, TB4, TB6, and TB8 breaker components are UL listed in File E-42263. Fused molded case switches are UL listed in File E-57546. 3-38 Prices and data subject to change without notice BuyLog Catalog These breakers are available only with noninterchangeable adjustable magnetic trip, in frame Types E, F, J, K, and Tri-Break. All breakers are shipped factory assembled, complete with Cu/Al line and load lugs. All magnetic only circuit breakers and limiters are UL Component Recognized in Files E-11592 and E-66390, respectively, unless otherwise noted. Accessories Order accessories from the appropriate table: --Thermal Magnetic Circuit Breakers, Magnetic Circuit Breakers, and Molded Case Switches1--pages 3-85 to 3-104. --MicroVersaTrip Plus or Power+ 4-function J and K frame Solid State Circuit Breakers--pages 3-85 to 3-104. --Spectra RMS Breakers--pages 3-83 to 3-84 and 3-92 to 3-104. --Spectra RMS Breakers with MicroVersaTrip Plus Trip Units or MicroVersaTrip PM Trip Units--pages 3-83 to 3-84, 3-92 to 3-104 and 3-106 to 3-109. 1Installation of accessories in molded case switches requires dummy trip; see page 3-91 for information. Dummy trip not required for Tri-Break or Q Line molded case switches. Molded Case Circuit Breaker and Switch Terminal Configuration Code Order standard Cu/Al lugs by using suffix codes presented. Order lugs separately if special lugs are required. For optional lugs, see pages 3-101 and 3-102. Breaker/Switch Type Suffix Blank WL XL X2 LL TQD/TJD Load Lugs Only Line and Load Lugs -- Line Lugs Only No Lugs Molded Case Breakers, Thermal Magnetic Load Lugs Only Line and Load Lugs -- Load Lugs Only No Lugs Molded Case Switch Line and Load Lugs -- No Lugs Line Lugs Only Load Lugs Only Spectra RMSTM Breakers No Lugs Order Lugs Separately J.K. MicroVersaTrip(R) Breakers No Lugs Order Lugs Separately Mine DutyTM Breakers No Lugs Order Lugs Separately Mag-Break(R) Breakers Line and Load Lugs -- -- -- -- For E 150 circuit breakers suffix XL is used to specify "no lugs". www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers How To Order Spectra RMS Circuit Breakers with MicroVersa Trip Plus Trip Units How to Order --Determine the required breaker frame (i.e., 150, 400, 600, 800, or 1200 amperes), IC rating, and load requirements (UL Standard or 100%). Determine overcurrent protective functions (LI, LSI, LIG, LSIG). Select frame product number and list price from table on pages 3-59 to 3-61 and 3-66 to 3-68. --Select and price the required rating plug from table below. The sensor rating of frame must match the sensor rating of the rating plug in table. --Select and price lugs and lug covers as required from page 3-102 and 3-103. --Select and price appropriate combination of Power Management System accessories from pages 3-106 to 3-109. --Select and price any other accessories from pages 3-83 to 3-84 and 3-92 to 3-100. MicroVersaTrip Plus and PM Rating Plug Selection -- All Plugs List Price, $106.00 Trip Function Definitions Long-Time (L) Short-Time (S) Instantaneous (I) Ground Fault (G) Control Power (CP) Note: All Spectra RMS breakers with ground fault option will have a breaker cable. If the breaker is connected to a 3O4w or 1O3w service, a terminal block or junction box is required for connection to the neutral current sensor. Adjustable current setting Adjustable long-time delay Adjustable short-time pick-up Adjustable short-time delay with I2t Adjustable short-time delay without I2t Adjustable pick-up Adjustable ground fault pick-up adjustable ground fault delay with I2t Adjustable ground fault delay without I2t +24 Vdc control power connection Circuit Breaker Frame Sensor Rating 150 SGHB, SGHH, SGLB, SGLL, SGPB, SGPP 400 Pricing Example SG600 frame, 400 ampere sensor, 400 ampere rating plug, 100kAIC, 100% rated. Trip functions to include long-time (L), short-time (S), instantaneous (I) and ground fault. 3-phase/4 wire system with 400 ampere neutral sensor. Load lugs only. 120 Vac shunt trip and two stage auxiliary switch (2AB) with signal level contacts. 600 800 Description Product Number Frame Rating Plug Load Lugs (3 pole kit) Terminal Block 400A neutral sensor 120 Vac Shunt Trip 2AB Aux. Switch SGPP36BD0400 SRPG400B400 TCLK365 SDCTBA11 TSRG204 SAST1 SAUXGAB2 List Price GO-135S $8987.00 $106.00 $42.00 $110.001 $532.00 $363.00 $295.00 1GO-135PM. SKHB, SKHH, SKLB, SKLL, SKPB, SKPP 1200 GO-135S Rating Plug Rating (Amperes) Rating Plug Product No. 60 80 100 125 150 150 200 225 250 300 350 400 300 400 450 500 600 300 400 500 600 700 800 600 700 800 1000 1200 SRPG150B60 SRPG150B80 SRPG150B100 SRPG150B125 SRPG150B150 SRPG400B150 SRPG400B200 SRPG400B225 SRPG400B250 SRPG400B300 SRPG400B350 SRPG400B400 SRPG600B300 SRPG600B400 SRPG600B450 SRPG600B500 SRPG600B600 SRPK800B300 SRPK800B400 SRPK800B500 SRPK800B600 SRPK800B700 SRPK800B800 SRPK1200B600 SRPK1200B700 SRPK1200B800 SRPK1200B1000 SRPK1200B12002 2Not suitable for use with 100% rated, 1000A breaker frame. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-39 Prices and data subject to change without notice MOLDED CASE CIRCUIT BREAKERS --When ordering, specify separate product numbers as follows: --Frame --Rating Plug --Lugs --Power Management Accessories --Other Accessories 3 Molded Case Circuit Breakers Industrial Circuit Breakers Spectra RMS Circuit Breakers with MicroVersaTrip PM Trip Units MicroVersaTrip PM Trip Unit The MicroVersaTrip PM trip unit adds power management system capability, advanced metering, and protective relays to the basic functions of MicroVersaTrip Plus. MicroVersaTrip PM trip units communicate directly on the GE POWER LEADER communications bus. Suitable for use in applications from 45 Hz to 66 Hz. Not suitable for 400 Hz. MOLDED CASE CIRCUIT BREAKERS Standard Features 3 --Adjustable Long-Time (L) pickup, 0.5-1.0X, and delay (3-4 bands). --Adjustable Instantaneous (I) pickup, 1.5-10X. --Local Overload and Short-Circuit Trip Indicators (T) with overload pickup warning. --Interchangeable trip rating plugs with test set jack for TVRMS test set. --Digital LCD display with four-button keypad for function selection and set point adjustment and sealable, clear Lexan cover for tamper-resistant settings. --True rms sensing for accurate response to high harmonic content waveforms. --EMI immunity per ANSI C37.90. --POWER LEADER Communications System Link with userselectable address assignment for COMNET communication. --Metering --3-Phase Ammeter with 4% accuracy. --3-Phase Voltmeter, 2% @ 1X, configurable for Wye and Delta systems. --Frequency Meter, 1 Hz --kW Meter, 7% (real power) --kVA Meter, 6% (apparent power) --kWh Meter, 6% (energy) Control Power 24 Vdc provides connection capability for +24 Vdc control power into the breaker via the distribution cable system. Note: MicroVersaTrip PM functions require 24 Vdc control power and voltage sensing signals. Universal Internal Accessories--Uses the same front-mounted, field-installable shunt trips, undervoltage releases, bell alarms, and auxiliary switches as standard Spectra RMS breakers. Accessory Lead Routing Left or Right--Side channels mean no extra space required for accessory leads. Current Limiting--SG600 frames rated 65kA and 100kA @ 480 Vac are UL listed as current limiting. Reverse Feed--Front-mounted interchangeable rating plugs mean all frames are UL listed for reverse feed. Wide Current Setting Range--Interchangeable rating plugs combined with 5 current sensors and 0.5-1.0X long time pickup yield ampere ratings from 30 to 1200A. 100% Continuous Current Rated--Optionally available for 100% UL continuous current rating applications. Optional Features --Adjustable Short-Time (S) pickup, 1.0-9.0C, and delay (4 bands) with I 2t IN/OUT selection. --Adjustable Ground fault (G) pickup, 0.2-1.0S, and delay (4 bands) with I 2t IN/OUT selection and trip indicator. The 4 short-time and ground fault delay bands provide broader system selectivity. --Protective Relays--User selectable in any combination from 1 to 5 relays --Current Unbalance Relay --Undervoltage Relay --Overvoltage Relay --Voltage Unbalance Relay --Power Reversal Relay 3-40 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers Spectra RMS Circuit Breakers with MicroVersaTrip PM Trip Units MicroVersaTrip PM Trip Unit Characteristics Current Setting (C) Pickup (Multiple of Rating Plus Amperes) (X) 0.50 to 1.0 in increments of 0.05 (11 Settings) Pick-Up (Multiple of Current Settings) (C) Delay (Seconds) Adjustable Instantaneous Pickup (Multiple of Rating Plug Amperes) (X) 1.5 to 9.0 in increments of 0.5 (16 Settings) I2t IN3 0.44 I2T OUT4 0.1, 0.2, 0.3, 0.4 (8 Bands) 1.5 to 10.0 in increments of 0.5 (18 Settings) Long-Time1 Short-Time Delay (Seconds) 2.4,4.9,9,8,20 (3-4 Bands) 2,3 Ground Fault Pick-Up (Multiple of Sensor Ampere Rating) (S) 0.2 to 1.0 in increments of 0.05 (17 Settings) Delay (Seconds) I2t IN5 0.41 I2t OUT4 0.1, 0.2, 0.3, 0.4 (8 Bands) X = Rating Plug Amperes S = Sensor Ampere Rating C = Long-Time Current Settings (Pickup) C = X Times Long-Time Pickup Setting 1 Pick-up fixed at 1.1C. 2 20-second delay (band) not available on SG frames. 3 Time delay at 600% of current setting at lower limit of each band. 4 Time delay shown at lower limit of each band. Pickup tolerances 10%. Ground Fault Pick-up not to exceed 1200 amperes. 5 Time delay at 200% of pickup setting at the lower limit of each band. PM Trip Unit Metering (M) Accuracy and Description Metering and Relaying (PM) Amperes (A) Current 4% Selectable Phase * * Voltage (V) Volts 2% Selectable Phase in L-L or L-N * * Energy (kWh/MWh) Watt hours 7% Total energy flow through breaker * * Real Power (kW/MW) Watts 6% L-L or L-N Power * * Apparent Power (kVA/MVA) Volt amps 6% L-L or L-N Power * * Frequency (45-66 Hz) Hertz 6% * * Voltage Unbalance Relay Adjustable pickup, 10 to 50% Adjustable delay, 1 to 15 seconds or OFF * Current Unbalance Relay Adjustable pickup, 10 to 50% Adjustable delay, 1 to 15 seconds or OFF * Undervoltage Relay Adjustable pickup, 50 to 90% Adjustable delay, 1 to 15 seconds or OFF * Overvoltage Relay Adjustable pickup, 110 to 150% Adjustable delay, 1 to 15 seconds or OFF * Power Reversal Relay Adjustable pickup, 0.01 MW to .90 MW Adjustable delay, 1 to 15 seconds or OFF * Communications POWER LEADERTM Communications System Link (comment) * * MOLDED CASE CIRCUIT BREAKERS Functions 3 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-41 Prices and data subject to change without notice Molded Case Circuit Breakers Industrial Circuit Breakers Spectra RMS Circuit Breakers with MicroVersaTrip PM Trip Units How to Order --Determine the required breaker frame (i.e., 150, 400, 600, 800, or 1200 amperes), IC rating, and load requirements (UL Standard or 100%). Determine overcurrent protective functions (LI, LSI, LIG, LSIG) and whether protective relaying is required. Select frame product number and list price from table on pages 3-59 to 3-61 and 3-66 and 3-68. --Select and price the required rating plug from table below. The sensor rating of frame must match the sensor rating of the rating plug in table. --Select and price lugs and lug covers as required from page 3-102 and 3-103. --Select and price appropriate combination of Power Management System accessories from pages 3-106 to 3-109. --Select and price an auxiliary switch as required from page 3-109. --Select and price any other accessories from pages 3-83 to 3-84 and 3-92 to 3-100. --When ordering, specify separate product numbers as follows: --Frame --Rating Plug --Lugs --Auxiliary Switch --Power Management System Accessories --Other Accessories Trip Unit Function Definitions MOLDED CASE CIRCUIT BREAKERS Long-Time (L) 3 Short-Time (S) Instantaneous (I) Ground Fault (G) Trip Indication Targets Full Metering (Standard) Protective Relay Functions Adjustable current setting Adjustable long-time delay Adjustable short-time pick-up Adjustable short-time delay with l2t Adjustable short-time delay without l2t Adjustable pick-up Adjustable ground fault pick-up Adjustable ground fault delay with l2t Adjustable ground fault delay without l2t Standard Amperes (A/kA) - Phase Selectable Voltage (V) - L-L or L-N and Phase Selectable Energy (kWh/MWh) Real Power (kW) - L-L or L-N Total Power (kVA) - L-L or L-N Frequency (45-66 Hz) Adjustable Undervoltage pick-up Adjustable Undervoltage delay or OFF Adjustable Overvoltage pick-up Adjustable Overvoltage delay or OFF Adjustable Voltage Unbalance pick-up Adjustable Voltage Unbalance delay or OFF Adjustable Current Unbalance pick-up Adjustable Current Unbalance delay or OFF Adjustable Power Reversal pick-up Adjustable Power Reversal delay or OFF overvoltage (OV) and power reversal (PR). Local metering values available at the breaker shall include Current (Amperes), Voltage (Volts), Energy (kWh), Real Power (kW), Apparent Power (kVA) and Frequency (Hz). The available system is 277/480 Vac, 3-phase/4-wire with 100 kAIC fault current available. The Distribution Cable Accessories are to be mounted on plates with all the necessary fuse protection, potential transformers, control power transformers, etc. Description Frame Rating Plug Line and Load Lugs (2-3 Pole Kits) Auxiliary Switch Power Supply Plate Voltage Conditioner Plate Junction Box Harness (2) 400A Neutral Current Sensor Product Number List Price GO Schedule SGPP36DD0400 SRPG400B400 $11387.00 $106.00 135PM 135S $42.00 $149.00 $1215.00 $1000.00 $155.00 $140.00 $532.00 135S 135S 135PM 135PM 135PM 135PM 135S TCLK635 SAUXPAB1 SPSA480 SVCA480Y SDCJBA SPCHA11 TSRG204 MicroVersaTrip Plus and PM Rating Plug Selection-- All Plugs List Price, $106.00 Circuit Breaker Frame Sensor Rating 150 SGHB, SGHH, SGLB, SGLL, SGPB, SGPP 400 600 800 Pricing Example SG600 ampere frame breaker, 100% UL rated with 400 ampere sensors and 400 ampere rating plug with line and load lugs. Trip functions to include adjustable long-time (L), short-time (S), instantaneous (I) and equipment ground fault (G) and internal protective relay functions of current unbalance (CU), voltage unbalance (VU), undervoltage (UV), 3-42 Prices and data subject to change without notice BuyLog Catalog SKHB, SKHH, SKLB, SKLL, SKPB, SKPP 1200 Rating Plug Rating (Amperes) 60 80 100 125 150 150 200 225 250 300 350 400 300 400 450 500 600 300 400 500 600 700 800 600 700 800 1000 1200 GO-135S Rating Plug Product No. SRPG150B60 SRPG150B80 SRPG150B100 SRPG150B125 SRPG150B150 SRPG400B150 SRPG400B200 SRPG400B225 SRPG400B250 SRPG400B300 SRPG400B350 SRPG400B400 SRPG600B300 SRPG600B400 SRPG600B450 SRPG600B500 SRPG600B600 SRPK800B300 SRPK800B400 SRPK800B500 SRPK800B600 SRPK800B700 SRPK800B800 SRPK1200B600 SRPK1200B700 SRPK1200B800 SRPK1200B1000 SRPK1200B12001 1Not suitable for use with 100% rated, 1000A breaker frame. www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers R-Frame Molded Case Circuit Breakers Solid-State Interchangeable Trip 400-2000A, 600 Vac, 65,100 kAIC @480V Standard and 100% Rated MicroVersaTripPlus Suitable for Reverse Feed How To Order: 1. Select frame product number. 2. Select rating plug for current rating from page 3-71. 3. Select appropriate accessories and lugs from page 3-105. Include suffix "s" for factory installation. Example Description Frame Rating Plug Neutral CT Shunt Trip Auxiliary Switch Padlocking Provision Line Side Terminations (Optional) Load Side Terminations Adapter Kit Lugs (2 per pole) Product Number TRPP36BD10 TR10B600 TSVG810A TPST12 TPAS2AB4 Standard (3)TP16FCA (1)TPLUGA16 (6)TPLUG108 R-Frame UL Listed Interrupting Ratings - rms Symmetrical Amperes Continuous Current Rating Frame Type 80% 100% Standard Break LA LL Interrupting Rating (rms sym.) 240 Vac 100,000 Amperes 480 Vac 65,000 Amperes 600 Vac 50,000 Amperes 240 Vac 125,000 Amperes Hi-Break(R) PA PP 480 Vac 100,000 Amperes MOLDED CASE CIRCUIT BREAKERS 600 Vac 65,000 Amperes MicroVersaTrip Plus Trip Unit Selection Trip Unit Function Definitions Long-Time (L) Adjustable current setting Adjustable long-time delay Short-Time (S) Adjustable short-time pick-up Adjustable short-time delay with I2t Adjustable short-time delay without I2t Instantaneous (I) Adjustable pick-up Ground Fault (G) Adjustable ground fault pick-up Adjustable ground fault delay with I2t Adjustable ground fault delay without I2t Trip Indication Target (T1, T2) Overload/short circuit targets (T1) Overload/short circuit/ground fault targets (T2) Zone Selective Interlock (Z1, Z2) Ground fault (Z1) Ground fault/short-time (Z2) 3 Trip Unit Functions Available OL, SC OL, SC, GF Zone Interlock GF (Z1) 2 Zone Interlock GF, ST (Z2) * -- -- -- * -- -- -- * -- * -- -- * * -- * -- -- * * -- * * -- * * -- * * -- * * -- * -- * Targets (T) R-Frame Breaker Function Code Long Time (L) Short Time (S) Instantaneous (I) A * -- * -- B * * * -- C * -- * D * * E * -- F * * G * * Ground Fault (G) 1 1 For single-phase, 3-wire or 3-phase, 4-wire GF applications select neutral-current sensor on page 3-105. 2 Zone interlocking requires purchase of interlock module TIM1 (120 Vac control voltage). Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-43 Prices and data subject to change without notice Molded Case Circuit Breakers Industrial Circuit Breakers 15-1200A Circuit Breakers Electric Trip Spectra RMS Breakers Quick Reference Guide Ratings do not apply to molded case switches. The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage. Spectra RMS Circuit Breakers UL/CSA Ratings Solid-State with Interchangeable Trip Unit (Rating Plug) Circuit Breaker Type Ampere Rating No. Poles Maximum Vac H W D A B C E Approx. Ship Wt./Std. Pack 6.31 (160) 4.12 (105) 3.38 (86) 2.41 (61) 2.47 (63) .69 (18) .72 (18) 5.65 lb/ 1 10.12 (257) 4.12 (105) 3.81 (97) 3.87 (98) 3.87 (98) .69 (18) 1.19 (30) 9.15 lb/ 1 10.09 (256) 5.50 (140) 3.81 (97) 4.45 (113) 3.30 (84) .91 (23) 1.18 (30) 15.85 lb/ 1 UL Listed Interrupting Rating-- kA 240 Vac 480 Vac Dimensions Inches (mm) 600 Vac SE150 Current Limiting (UL File No. E-11592; CSA LR 40350) 1 SED2 15-150 SEH2 SEL 15-150 SEP 2 480 3 600 2 480 3 600 2 480 3 600 2 480 3 600 -- 18 18 14 -- 65 25 100 65 200 100 18 -- 25 -- 25 SF-250 Current Limiting (UL File No. E-11592; CSA LR 40350) 1 SFH2 70-250 SFL 70-250 SFP 2 480 3 600 2 480 3 600 2 480 3 600 -- 65 35 22 -- 100 65 25 -- 200 100 25 SG600 Current Limiting (UL File No. E-11592; CSA LR 40350) 3 SGH12,4 60-150 SGD MOLDED CASE CIRCUIT BREAKERS 125-400 3 SGH42 SGH62 250-600 4 SGL1 SGP14 3 600 65 35 25 240 65 -- -- 65 35 25 2 2 60-150 SGL4 125-400 SGP4 SGL6 250-600 SGP6 3 2 600 3 600 2 600 65 35 25 3 600 3 600 100 65 65 3 600 200 100 65 2 600 3 600 100 65 65 2 600 3 600 200 100 65 2 600 3 600 100 65 65 2 600 3 600 200 100 65 600 65 50 25 600 100 65 42 600 200 100 65 600 65 50 25 600 100 65 42 600 200 100 65 5 5 SK1200 (UL File No. E-11592; CSA LR 40350) 3 2 SKH8 3 SKL8 300-800 2 3 2 SKP8 3 2 SKH12 15.50 (394) SKL12 SKP12 600-1200 3 2 3 1 UL listed as HACR (heating, air conditioning and refrigeration) type. 2 Not current-limiting circuit breaker. 3 Includes MicroVersaTrip Plus Trip Units and MicroVersaTrip PM Trip Units. 3-44 Prices and data subject to change without notice 5.50 (140) 8.56 (217) 5.69 (145) 1.38 (35) .62 (16) 6 3 2 8.25 (210) 47.6 lb/ 1 6 4 MicroVersaTrip PlusTM Trip Units and MicroVersaTrip PMTM Trip Units only. 5 Add 1.76 inches (45 mm) to each end with lugs and lug cover installed. 6 Add 4.00 inches (101 mm) to upper end for SKP (100 kAIC-480V) lug cover. BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers 15-1200A Circuit Breakers Electric Trip Spectra RMS Breakers Quick Reference Guide Ratings do not apply to molded case switches IEC/JIS Ratings Solid-State with Interchangeable Trip Unit (Rating Plug) Japanese Industry Standard Interruption Capacity kA IEC 947-2 Interruption Capacity -- kA Circuit Breaker Type Ampere Rating No. Poles 220-240 Vac Icu I cs 380-415 Vac I cu I cs 500 Vac I cu I cs 690 Vac I cu I cs Vac 220-240 380-415 500 690 SE150 Current Limiting, 15-32A 2 SED 3 15-32 2 SEH 3 2 SEL 3 15-32 2 SEP 3 18 9 10 5 65 33 15 10 100 50 20 15 200 100 20 20 18 9 14 7 65 33 35 17 -- -- 4 -- 4 -- 6 -- 6 -- 8 -- -- -- -- 18 10 -- -- 65 15 -- -- 8 -- 3 -- 3 -- 100 20 10 10 5 5 200 20 -- -- 14 -- 7 -- -- -- 18 14 25 -- 12 -- -- -- 65 25 -- -- 40 -- 20 -- 5 -- 5 -- 4 -- 6 -- -- -- -- 8 -- 3 -- 10 5 SE SE150 Current Limiting, 40-160A 2 SED 3 40-160 2 SEH 3 2 SEL 3 40-160 2 SEP 3 100 50 65 33 200 100 100 50 65 33 35 17 50 25 -- -- 25 -- 12 -- 40 -- 20 -- -- 10 5 -- -- -- -- 14 -- 7 -- 100 65 200 100 65 25 14 -- -- -- 18 -- -- 25 -- 5 -- 65 10 SF250 Current Limiting 70-250 2 3 2 SFL 70-250 SFP 3 2 3 SG600 Current Limiting -- 60-150 SGH11 3 100 50 65 33 200 100 100 50 65 33 25 13 65 33 25 13 65 33 25 13 2 SGH4 125-400 3 2 SGH6 250-600 SGL11 60-150 SGP11 3 -- 3 -- 3 100 50 65 33 200 100 100 50 100 50 65 33 200 100 100 50 100 50 65 33 200 100 100 50 65 16 50 100 25 140 2 SGL4 3 125-400 SGP4 3 250-600 SGP6 200 100 18 9 -- -- 65 25 -- -- 65 25 65 25 100 65 200 100 100 65 200 100 100 65 200 100 -- -- 18 -- 9 -- 18 -- 9 -- 18 -- 9 -- -- -- -- -- 35 -- 18 -- 14 -- 7 -- 50 -- 25 -- 18 -- 9 -- 25 -- 14 -- 65 18 SF -- 18 -- 18 -- 18 -- -- -- -- -- 35 -- 22 -- 65 -- 35 -- 35 22 -- 65 -- 35 -- 35 -- 22 -- 65 35 14 -- 7 50 -- 25 -- 18 -- 9 -- 35 -- 18 -- 14 -- 7 -- 50 25 18 9 13 25 13 -- -- 65 50 25 -- 65 16 42 21 14 14 100 65 42 14 35 85 25 50 25 18 18 140 85 50 18 65 16 50 13 25 13 -- -- 65 50 25 -- 100 25 65 21 42 16 14 14 100 65 42 14 140 35 70 25 50 25 18 18 140 85 50 18 2 3 65 18 -- 2 SGL6 33 100 -- -- 35 -- 2 3 65 -- 18 -- MOLDED CASE CIRCUIT BREAKERS SFH 3 SG SK1200 2 SKH8 3 2 SKL8 300-800 3 2 SKP8 3 2 SKH12 3 2 SKL12 600-1250 3 SK 2 SKP12 1 3 MicroVersaTrip PlusTM trip system only. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-45 Prices and data subject to change without notice Molded Case Circuit Breakers Industrial Circuit Breakers 10-1200A Circuit Breakers Thermal Magnetic Trip Ratings do not apply to molded case switches. The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage. TFJ, TFK, THFK TJJ, TJK, THJK Quick Reference Guide E150 (UL File E-11592; Fixed Thermal Magnetic Trip Unit; CSA LR 57114) Circuit Breaker Type TEB2 Ampere Rating 10-1003 ac dc 120 1 120 125 10 2 240 THED2 250 -- 1 277,3474 125 2 480 250 10-150 3 600 500 15-30 1 277,3474 125 15-100 2 480 250 10-1003 15-100 15-100 Vac No. Poles 3 TED2 UL Listed Interrupting Ratings-- kA Maximum Voltage Rating 3 480,600 -- -- 120/ 240 15-150 277 480 -- -- 10 -- -- -- 14 10 18 -- 18 250 500 1 -- -- -- 5 -- -- -- 5 -- -- 4 1/8 10 -- -- 1 3/8 10 -- 10 10 4 1/8 11/16 28 lb/8 -- -- 1 3/8 -- 26 lb/24 205 -- 10 -- -- -- -- -- 14 -- -- -- -- 205 -- 65 65 -- 65 Approx. Ship Wt./Std. Pack 125 -- -- Dimensions (In.) 600 -- 110-150 TEL6 240 Vdc -- 25 18 -- 65 25 -- H W D A B 1 3/8 6 5/16 6 5/16 2 3/4 2 3/4 6 5/16 C E 26 lb/24 -- 3 3/8 2 41/64 2 15/64 23/32 11/16 28 lb/8 26 lb/24 -- 3 3/8 3 3/8 2 41/64 2 15/64 23/32 2 41/64 2 15/64 4 1/8 24 lb/12 23/32 11/16 24 lb/12 24 lb/12 28 lb/8 42 3 600 -- -- 100 100 -- 6 5/16 4 1/8 3 29/32 2 7/16 2 15/32 11/16 23/32 3 1/2 lb/1 F225 (UL File E-11592; TFJ, Fixed Thermal Magnetic Trip Unit; TFK, THFK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350) UL Listed Interrupting Ratings-- kA MOLDED CASE CIRCUIT BREAKERS Circuit Breaker Ampere Type Rating 3 2 TFJ TFK2 No. Poles ac dc 70-225 2 480 250 70-250 3 600 500 70-225 2 Maximum Voltage Rating THFK 70-225 TFL6 70-225 2 480 250 3 600 -- 2 480 250 3 600 -- 3 600 -- Vac 120 120/ 240 240 277 480 600 125 -- -- -- 25 -- Dimensions (In.) Vdc 22 -- 18 -- -- -- 25 -- 22 -- -- 65 -- 25 -- 100 100 -- 65 18 25 500 1 10 -- 10 10 10 -- -- -- 20 5 -- -- -- -- -- -- -- -- -- 18 250 H W D A B 10 1/8 4 1/8 3 13/16 3 7/8 3 7/8 C E 11/16 1 3/16 Approx. Ship Wt./Std. Pack 10 lb/1 12 lb/1 10 1/8 4 1/8 3 13/16 3 7/8 3 7/8 11/16 1 3/16 10 1/8 4 1/8 3 13/16 3 7/8 3 7/8 11/16 1 3/16 10 1/8 4 1/8 3 13/16 3 7/8 3 7/8 11/16 1 3/16 10 lb/1 12 lb/1 10 lb/1 12 lb/1 -- J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350) TJJ, TJK4 125-400 TJK6 250-600 THJK4 2 600 125-400 250-600 -- -- 42 -- 30 22 -- 10 -- 20 10 3 500 20 20 2 250 40 -- -- -- 40 -- -- -- 2 500 600 600 3 THJK6 250 20 8 -- 3 2 600 3 250 -- 250 -- -- -- -- -- -- -- 42 65 65 -- -- -- 30 35 35 22 25 25 -- -- -- 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16 16 lb/1 17 1/2 lb/1 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16 18 lb/1 20 lb/1 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16 16 lb/1 17 1/2 lb/1 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16 18 lb/1 20 lb/1 K1200 (UL File E-11592; Interchangeable Thermal Magnetic Trip Unit; CSA LR 40350) TKM8 300-800 2 600 TKM12 600-1200 2 250 -- -- 42 -- 30 22 -- 500 3 600 -- -- -- 42 -- 30 22 -- 10 -- 20 22 -- -- 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8 39 lb/1 300-800 2 600 3 THKM12 600-1200 2 38 lb/1 41 1/2 lb/1 3 THKM8 33 lb/1 600 250 -- -- -- -- 65 -- 35 25 -- -- -- 65 -- 35 25 -- 407 -- -- -- -- -- 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8 33 lb/1 39 lb/1 38 lb/1 41 1/2 lb/1 3 1UL listed with poles in series for 500 Vdc ungrounded battery applications. 2 All UL listed as HACR type. 3 10 amp not UL listed. 4 UL listed/CSA Certified for 10kA @ 347 Vac (TED) and 18kA @ 347V 5 UL listed at 10,000 amps. 6 Discontinued 7 Also 10,000 amps at 500 Volts dc. Not UL listed. 8 500 Vdc on TJK only. (THED). Also rated 10kA @ 480V but not UL listed. 3-46 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Molded Case Circuit Breakers Quick Reference Guide Ratings do not apply to molded case switches. The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage. TJC TJL6S R Frame1 (UL File E-11592; Interchangeable Solid-State MicroVersaTrip Plus Trip Unit; CSA LR 10263) UL Listed Interrupting Ratings-- rms Symmetrical Amps (In Thousands) Maximum Voltage Rating Circuit Breaker Type Ampere Rating No. Poles ac dc 120 120/240 240 277 480 600 125 250 H W D A B C E Approx. Ship Wt./Std. Pack TRL...10, 16 400-1600 3 600 -- -- -- 100 -- 65 50 -- -- 17 1/2 13 1/2 8 5/16 -- -- -- -- 90/1 TRP...10, 16 400-1600 3 600 -- -- -- 125 -- 100 65 -- -- 17 1/2 13 1/2 8 5/16 -- -- -- -- 90/1 TRL...20 800-2000 3 600 -- -- -- 100 -- 65 50 -- -- 20 13 1/2 8 5/16 -- -- -- -- 96/1 TRP...20 800-2000 3 600 -- -- -- 125 -- 100 65 -- -- 20 13 1/2 8 5/16 -- -- -- -- 96/1 -- 200 200 -- -- 10 5/16 4 1/8 3 5/8 2 21/32 Vac Vdc Dimensions (In.) Tri-Break (UL File E-42263; Integrally Fused, Thermal Magnetic Trip Unit) TB12,3 15-100 3 600 -- -- -- 200 6 9/32 11/16 23/32 TB42,4 125-400 TB62,4 300-600 3 600 -- -- -- 200 -- 200 200 -- -- 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8 TB82,4 600-800 3 600 -- -- -- 200 -- 200 100 -- -- 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8 3 600 -- -- -- 200 -- 200 200 -- -- 16 1/8 8 1/4 4 1/2 3 15/16 9 13/16 1 3/8 1 3/16 8 lb/1 31 lb/1 33 lb/1 53 lb/1 55 lb/1 53 lb/1 55 lb/1 TEC 3-150 6 2 480 250 3 600 -- -- -- 10 -- -- 10 10 -- 10 6 5/16 4 1/8 3 3/8 2 41/64 2 15/64 11/16 23/32 21 lb/6 3 1/2 lb/1 TEML 3-150 3 600 250 -- -- 100 -- 65 25 -- -- 6 5/16 4 1/8 3 7/8 2 41/64 2 15/64 11/16 23/32 TEC & TECL7 3-150 3 600 -- -- -- 100 -- 100 100 -- -- 8 3/16 4 1/8 3 3/8 2 41/64 1.2 lb/1 2 15/64 11/16 23/32 TECL Only 225 3 600 -- -- -- 25 -- 22 18 -- -- 10 1/8 4 1/8 3 13/16 3 7/8 TFC 3 7/8 11/16 1 3/16 10 lb/1 12 lb/1 TBC4 225-400 3 600 -- -- -- 100 -- 100 100 -- -- 16 1/8 8 1/4 4 1/2 3 15/16 9 13/16 1 3/8 1 3/16 31 lb/1 33 lb/1 TJC 400-600 3 600 -- -- -- 42 -- 30 22 -- -- 10 1/8 8 1/4 3 13/16 3 13/16 3 13/16 1 3/8 1 3/16 16 lb/1 17 1/2/1 TBC6 600 3 600 -- -- -- 100 -- 100 100 -- -- 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8 TKC 800-1200 3 600 -- -- -- 42 -- 30 22 -- -- 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8 53 lb/1 MOLDED CASE CIRCUIT BREAKERS Mag-Break (UL Files E-11592, E-66390; Magnetic Trip Unit) 5 55 lb/1 38 lb/1 41 1/2/1 TBC8 800 3 600 -- -- -- 100 -- 100 100 -- -- 21 7/8 8 1/4 5 7/8 8 9/16 12 1/16 1 3/8 5/8 53 lb/1 55 lb/1 MicroVersaTrip (UL File E-11592; Solid-State Trip Units) TJ4V 8,9 THJ4V8,9 150-600 3 600 -- -- TJL4V8 42 42 65 65 100 100 -- 30 22 35 25 65 30 -- -- 10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16 -- -- TK4V8 800-1200 3 600 -- -- 42 42 -- 30 22 -- -- 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8 TKL4V 8 800-1200 3 600 -- -- 100 100 -- 65 42 -- -- 15 1/2 8 1/4 5 1/2 8 9/16 5 11/16 1 3/8 5/8 60-600 3 600 -- -- 65 65 -- 35 25 -- -- 16 1/8 8 1/4 3 13/16 3 15/16 9 13/16 1 3/8 1 3/16 3 13/16 3 15/16 9 13/16 1 3/8 1 3/16 TJH1S-6S -- -- 60-600 3 600 -- -- 100 100 -- 65 30 -- -- 16 1/8 8 1/4 TKH8S, 12S 300-1200 3 600 -- -- 65 65 -- 50 25 -- -- 21 7/8 8 1/4 5 1/2 8 9/16 12 11/16 1 3/8 5/8 -- TKL8S, 12S 300-1200 3 600 -- -- 100 100 -- 65 42 -- -- 21 7/8 8 1/4 5 1/2 8 9/16 12 11/16 1 3/8 5/8 -- TJL1S-6S 1 Rotary handle (not toggle handle). 2 UL listed with internally mounted accessories at 100,000 amps IC. Contact GE Sales Office for availability of 200 kAIC ratings with internal accessories. -- 5 Per UL 489, interrupting capacities are not shown on product label. 6 Discontinued. 7 Ratings shown for TEC in combination with TECL. 8 With Power+ 4 trip unit. 9 Suitable for single-phase, use outer two poles. 3 CSA LR 57114. 4 CSA LR 40350. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-47 Prices and data subject to change without notice 3 Molded Case Circuit Breakers Industrial Circuit Breakers 15-150A Circuit Breakers Electronic Trip Spectra RMS SE150 Line Circuit Breakers Features --Interchangeable trip using rating plugs --True digital rms sensing --Universal internal accessories UL listed for field installation --Adjustable instantaneous with short-time tracking function --CE marked SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR GO-135S SEL, SEP UL Current Limiting 2-Pole, UL/CSA: 150A, 480 Vac Max., IEC 947-2: 160A, 415 Vac Max. Rating Plug Frame Adj. Inst. Trip Range Amps UL 489 IC @480 Vac Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac MOLDED CASE CIRCUIT BREAKERS 18kA Ampere Rating Low High 15 20 25 30 40 50 60 70 80 90 100 110 125 150 43 58 73 87 118 148 178 206 236 267 297 328 374 450 182 254 332 415 501 637 777 863 999 1138 1280 1426 1640 1991 Product Number SRPE30A15 SRPE30A20 SRPE30A25 SRPE30A30 SRPE60A40 SRPE60A50 SRPE60A60 SRPE100A70 SRPE100A80 SRPE100A90 SRPE100A100 SRPE150A110 SRPE150A125 SRPE150A150 List Price $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor 25kA Product Number List Price Product Number 30 SEDA24AT0030 $214.00 SEHA24AT0030 $530.00 60 SEDA24AT0060 $214.00 SEHA24AT0060 $530.00 100 SEDA24AT0100 $312.00 SEHA24AT0100 $634.00 150 SEDA24AT0150 $837.00 SEHA24AT0150 $1427.00 Product Number List Price TCAL18 $3.00 SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR Wire Range 12-3/0 Cu 12-3/0 Al GO-135S 2-Pole, UL/CSA: 150A, 480 Vac Max., IEC 947-2: 160A, 415 Vac Max. Rating Plug Frame Adj. Inst. Trip Range Amps UL 489 IC @480 Vac Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 65kA 3 List Price Ampere Rating Low High 15 20 25 30 40 50 60 70 80 90 100 110 125 150 43 58 73 87 118 148 178 206 236 267 297 328 374 450 182 254 332 415 501 637 777 863 999 1138 1280 1426 1640 1991 Product Number SRPE30A15 SRPE30A20 SRPE30A25 SRPE30A30 SRPE60A40 SRPE60A50 SRPE60A60 SRPE100A70 SRPE100A80 SRPE100A90 SRPE100A100 SRPE150A110 SRPE150A125 SRPE150A150 List Price $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 3-48 Prices and data subject to change without notice 100kA Current Sensor Product Number List Price Product Number List Price 30 SELA24AT0030 $549.00 SEPA24AT0030 $895.00 60 SELA24AT0060 $549.00 SEPA24AT0060 $895.00 Product Number List Price TCAL18 $3.00 Wire Range 12-3/0 Cu 12-3/0 Al 100 SELA24AT0100 $744.00 SEPA24AT0100 $1179.00 150 SELA24AT0150 $1808.00 SEPA24AT0150 $2777.00 BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers 15-150A Circuit Breakers Electronic Trip Spectra RMS SE150 Line Circuit Breakers SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR GO-135S 3-Pole, UL/CSA: 150A, 600 Vac Max., IEC 947-2: 160A, 690 Vac Max. Rating Plug Frame Adj. Inst. Trip Range Amps UL 489 IC @480 Vac Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 18kA Ampere Rating Low High 15 20 25 30 40 50 60 70 80 90 100 110 125 150 43 58 73 87 118 148 178 206 236 267 297 328 374 450 182 254 332 415 501 637 777 863 999 1138 1280 1426 1640 1991 Product Number SRPE30A15 SRPE30A20 SRPE30A25 SRPE30A30 SRPE60A40 SRPE60A50 SRPE60A60 SRPE100A70 SRPE100A80 SRPE100A90 SRPE100A100 SRPE150A110 SRPE150A125 SRPE150A150 List Price $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor Product Number 25kA List Price Product Number List Price 30 SEDA36AT0030 $382.00 SEHA36AT0030 $632.00 60 SEDA36AT0060 $382.00 SEHA36AT0060 $632.00 100 SEDA36AT0100 $492.00 SEHA36AT0100 $734.00 150 SEDA36AT0150 $1253.00 SEHA36AT0150 $1815.00 Product Number List Price TCAL18 $3.00 Wire Range 12-3/0 Cu SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR 12-3/0 Al GO-135S 3-Pole, UL/CSA: 150A, 600 Vac Max., IEC 947-2: 160A, 690 Vac Max. Frame UL 489 IC @480 Vac Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 65kA Ampere Rating Low High 15 20 25 30 40 50 60 70 80 90 100 110 125 150 43 58 73 87 118 148 178 206 236 267 297 328 374 450 182 254 332 415 501 637 777 863 999 1138 1280 1426 1640 1991 Product Number SRPE30A15 SRPE30A20 SRPE30A25 SRPE30A30 SRPE60A40 SRPE60A50 SRPE60A60 SRPE100A70 SRPE100A80 SRPE100A90 SRPE100A100 SRPE150A110 SRPE150A125 SRPE150A150 List Price $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 100kA Current Sensor Product Number List Price Product Number List Price 30 SELA36AT0030 $753.00 SEPA36AT0030 $1189.00 60 SELA36AT0060 $753.00 SEPA36AT0060 $1189.00 100 SELA36AT0100 $895.00 SEPA36AT0100 $1482.00 150 SELA36AT0150 $2165.00 SEPA36AT0150 $3477.00 Product Number List Price TCAL18 $3.00 Wire Range 12-3/0 Cu 12-3/0 Al 3 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog MOLDED CASE CIRCUIT BREAKERS Rating Plug Adj. Inst. Trip Range Amps 3-49 Prices and data subject to change without notice Molded Case Circuit Breakers Industrial Circuit Breakers 15-150A Circuit Breakers Thermal-Magnetic Trip E150 Line Circuit Breakers Types TEB, TED, THED Noninterchangeable Trip Note: All UL listed as HACR type except 10 ampere 60C/75F Conductor 10-150 Amperes Rating Through 100 Amperes 120-600 Vac 75C above 100 Amperes 125, 250 Vdc Single Pole -- Includes Cu/Al load lugs only. If line lugs are required, add suffix "WL" to Product Number. Type TEB Ampere Rating 10 15 20 25 30 35 40 45 50 60 70 80 90 100 Type TED 120 Vac 125 Vdc 347 Vac1 277 Vac 125 Vdc Product Number List Price Product Number TEB1110102 TEB1110153 TEB1110203 TEB111025 TEB111030 TEB111035 TEB111040 TEB111045 TEB111050 TEB111060 TEB111070 TEB111080 TEB111090 TEB111100 $78.50 $78.50 $78.50 $78.50 $78.50 $78.50 $78.50 $78.50 $78.50 $78.50 $134.00 $134.00 $134.00 $134.00 TED1130102 TED1130153 TED1130203 TED113025 TED113030 TED113035 TED113040 TED113045 TED113050 TED113060 TED113070 TED113080 TED113090 TED113100 GO-135B Type THED List Price $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $159.00 $159.00 $159.00 $159.00 347 Vac1 277 Vac Product Number List Price Product Number List Price TED1140153 TED1140203 TED114025 TED114030 -- -- -- -- -- -- -- -- -- $152.00 $152.00 $152.00 $152.00 -- -- -- -- -- -- -- -- -- THED113015 THED113020 THED113025 THED113030 -- -- -- -- -- -- -- -- -- $229.00 $229.00 $229.00 $229.00 -- -- -- -- -- -- -- -- -- Product Number THED1140153 THED1140203 THED114025 THED114030 -- -- -- -- -- -- -- -- -- Two Pole -- Includes Cu/Al load lugs. For optional lugs, see page 3-101 and 3-102. MOLDED CASE CIRCUIT BREAKERS Type TEB 3 240 Vac, 250 Vdc GO-135B 480 Vac, 250 Vdc Product Number List Price Product Number 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150 TEB122010WL2 TEB122015WL TEB122020WL TEB122025WL TEB122030WL TEB122035WL TEB122040WL TEB122045WL TEB122050WL TEB122060WL TEB122070WL TEB122080WL TEB122090WL TEB122100WL -- -- -- $159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $261.00 $261.00 $261.00 $261.00 -- -- -- TED124010WL2 TED124015WL TED124020WL TED124025WL TED124030WL TED124035WL TED124040WL TED124045WL TED124050WL TED124060WL TED124070WL TED124080WL TED124090WL TED124100WL TED124110WL TED124125WL TED124150WL $416.00 $416.00 $416.00 $416.00 -- -- -- -- -- -- -- -- -- Type THED, Hi-Break 4 Type TED Ampere Rating List Price List Price $290.00 $290.00 $290.00 $290.00 $290.00 $290.00 $290.00 $290.00 $290.00 $290.00 $377.00 $377.00 $377.00 $377.00 $1000.00 $1000.00 $1000.00 480 Vac, 250 Vdc Product Number List Price -- THED124015WL THED124020WL THED124025WL THED124030WL THED124035WL THED124040WL THED124045WL THED124050WL THED124060WL THED124070WL THED124080WL THED124090WL THED124100WL -- -- -- -- $560.00 $560.00 $560.00 $560.00 $560.00 $560.00 $560.00 $560.00 $560.00 $653.00 $653.00 $653.00 $653.00 -- -- -- 1Suitable for 10 kAIC at 480 Vac, but not labeled or UL listed. 2Not UL listed 3Single-pole, 15-and 20-ampere breakers are also UL listed as switching duty breakers, suitable for switching 120 Vac (TEB), 277, 347 Vac (TED, THED) fluorescent lighting loads. 4Two-pole breaker is furnished in three-pole case. 3-50 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers 15-150A Circuit Breakers Thermal-Magnetic Trip E150 Line Circuit Breakers Types TEB, TED, THED Note: All UL listed as HACR type except 10 ampere 60C/75F Conductor 10-150 Amperes Rating Through 100 Amperes 120-600 Vac 75C above 100 Amperes 125, 250 Vdc Three Pole -- Includes Cu/Al load lugs. For optional lugs, see page 3-101 and 3-102. Type TEB GO-135B Type TED 240 Vac 480 Vac Ampere Rating Product Number List Price Product Number 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150 100NA 150NA TEB132010WL1 TEB132015WL TEB132020WL TEB132025WL TEB132030WL TEB132035WL TEB132040WL TEB132045WL TEB132050WL TEB132060WL TEB132070WL TEB132080WL TEB132090WL TEB132100WL -- -- -- -- -- $240.00 $240.00 $240.00 $240.00 $240.00 $240.00 $240.00 $240.00 $240.00 $240.00 $339.00 $339.00 $339.00 $339.00 -- -- -- -- -- TED134010WL1 TED134015WL TED134020WL TED134025WL TED134030WL TED134035WL TED134040WL TED134045WL TED134050WL TED134060WL TED134070WL TED134080WL TED134090WL TED134100WL TED134110WL TED134125WL TED134150WL TED134Y1002 TED134Y1502 Type THED, Hi-Break 600 Vac List Price $377.00 $377.00 $377.00 $377.00 $377.00 $377.00 $377.00 $377.00 $377.00 $377.00 $445.00 $445.00 $445.00 $445.00 $1198.00 $1198.00 $1198.00 $377.00 $967.00 480 Vac 600 Vac Product Number List Price Product Number Product Number List Price TED136010WL1 TED136015WL TED136020WL TED136025WL TED136030WL TED136035WL TED136040WL TED136045WL TED136050WL TED136060WL TED136070WL TED136080WL TED136090WL TED136100WL TED136110WL TED136125WL TED136150WL TED136Y1002 TED136Y1502 $439.00 $439.00 $439.00 $439.00 $439.00 $439.00 $439.00 $439.00 $439.00 $439.00 $534.00 $534.00 $534.00 $534.00 $1198.00 $1198.00 $1198.00 $445.00 $967.00 -- THED134015WL -- -- THED134030WL -- -- THED134045WL -- -- THED134070WL -- THED134090WL THED134100WL THED134110WL THED134125WL THED134150WL -- -- -- THED136015WL THED136020WL THED136025WL THED136030WL THED136035WL THED136040WL THED136045WL THED136050WL -- THED136070WL -- THED136090WL THED136100WL THED136110WL THED136125WL THED136150WL -- -- -- $655.00 $655.00 $655.00 $655.00 $655.00 $655.00 $655.00 $655.00 -- $742.00 -- $742.00 $742.00 $1683.00 $1683.00 $1683.00 -- -- 1Not UL listed. MOLDED CASE CIRCUIT BREAKERS 2Includes factory-installed dummy trip. Accessories: See pages 3-85 to 3-104. 3 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-51 Prices and data subject to change without notice Molded Case Circuit Breakers Industrial Circuit Breakers 70-250A Circuit Breakers Electronic Trip Spectra RMS SF250 Line Circuit Breakers SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR GO-135S SFH UL Current Limiting 2-Pole, UL/CSA: 250A, 480 Vac Max., IEC 947-2: 250A, 415 Vac Max. Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 70 90 100 110 125 150 175 200 225 250 205 265 295 325 370 440 515 590 665 736 700 900 1000 1100 1250 1500 1750 2000 2250 2500 35kA Product Number List Price Current Sensor Product Number List Price Product Number List Price SRPF250A70 SRPF250A90 SRPF250A100 SRPF250A110 SRPF250A125 SRPF250A150 SRPF250A175 SRPF250A200 SRPF250A225 SRPF250A250 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 250 SFHA24AT0250 $1134.00 TCAL29 $8.00 Wire Range 8-350 Cu SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR 8-350 Al GO-135S SFL, SFP UL Current Limiting 2-Pole, UL/CSA: 250A, 480 Vac Max., IEC 947-2: 250A, 415 Vac Max. Rating Plug Frame UL 489 IC @480 Vac MOLDED CASE CIRCUIT BREAKERS Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 3 70 90 100 110 125 150 175 200 225 250 205 265 295 325 370 440 515 590 665 736 700 900 1000 1100 1250 1500 1750 2000 2250 2500 Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 65kA Product Number List Price Current Sensor Product Number SRPF250A70 SRPF250A90 SRPF250A100 SRPF250A110 SRPF250A125 SRPF250A150 SRPF250A175 SRPF250A200 SRPF250A225 SRPF250A250 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 250 SFLA24AT0250 100kA List Price Product Number List Price Product Number List Price $2790.00 TCAL29 $8.00 Wire Range 8-350 Cu $2175.00 SFPA24AT0250 SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR 8-350 Al GO-135S SFH UL Current Limiting 3-Pole, UL/CSA: 250A, 600 Vac Max., IEC 947-2: 250A, 690 Vac Max. Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac Adjustable Instantaneous Trip Ampere Range Ampere Rating Low 70 90 100 110 125 150 175 200 225 250 205 265 295 325 370 440 515 590 665 736 35kA High Product Number List Price 700 900 1000 1100 1250 1500 1750 2000 2250 2500 SRPF250A70 SRPF250A90 SRPF250A100 SRPF250A110 SRPF250A125 SRPF250A150 SRPF250A175 SRPF250A200 SRPF250A225 SRPF250A250 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 3-52 Prices and data subject to change without notice Current Sensor Product Number List Price Product Number List Price 250 SFHA36AT0250 $1441.00 TCAL29 $8.00 Wire Range 8-350 Cu 8-350 Al BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers 70-250A Circuit Breakers Electronic Trip Spectra RMS SF250 Line Circuit Breakers SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR GO-135S SFL, SFP UL Current Limiting 3-Pole, UL/CSA: 250A, 600 Vac Max., IEC 947-2: 250A, 690 Vac Max. Rating Plug Frame UL 489 IC @480 Vac Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 205 265 295 325 370 440 515 590 665 736 700 900 1000 1100 1250 1500 1750 2000 2250 2500 65kA Product Number List Price SRPF250A70 SRPF250A90 SRPF250A100 SRPF250A110 SRPF250A125 SRPF250A150 SRPF250A175 SRPF250A200 SRPF250A225 SRPF250A250 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 100kA Current Sensor Product Number List Price Product Number List Price Product Number List Price 250 SFLA36AT0250 $2631.00 SFPA36AT0250 $3490.00 TCAL29 $8.00 Wire Range 8-350 Cu 8-350 Al MOLDED CASE CIRCUIT BREAKERS 70 90 100 110 125 150 175 200 225 250 Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 3 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-53 Prices and data subject to change without notice Molded Case Circuit Breakers Industrial Circuit Breakers 70-250A Circuit Breakers Thermal-Magnetic Trip F225 Line Circuit Breakers Types TFJ, TFK, THFK F225 Line Circuit Breakers --70-250 Amperes-TFJ Noninterchangeable Trip, suitable for reverse feed --70-225A TFK, THFK Interchangeable Trip, not suitable for reverse feed --480 or 600 Vac --250 Vdc Note: All TFJ, TFK and THFK breakers are UL listed as HACR Type TFK Type TFJ -- Noninterchangeable Trip GO-135B Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High Complete Breaker 480 Vac Max Product Number Complete Breaker 600 Vac Max List Price Product Number Two-Pole List Price Copper/Aluminum Lugs 70 80 90 100 110 125 150 175 200 225 250 600 700 600 600 660 600 700 800 900 1000 1000 900 1000 900 1250 1250 1250 1500 1750 2000 2250 2250 TFJ224070WL TFJ224080WL TFJ224090WL TFJ224100WL TFJ224110WL TFJ224125WL TFJ224150WL TFJ224175WL TFJ224200WL TFJ224225WL -- $1122.00 $1122.00 $1122.00 $1122.00 $1122.00 $1122.00 $1122.00 $1122.00 $1122.00 $1122.00 -- TFJ236070WL TFJ236080WL TFJ236090WL TFJ236100WL TFJ236110WL TFJ236125WL TFJ236150WL TFJ236175WL TFJ236200WL TFJ236225WL TFJ236250WL $1407.00 $1407.00 $1407.00 $1407.00 $1407.00 $1407.00 $1407.00 $1407.00 $1407.00 $1407.00 $2075.00 TCAL24 4-300 Cu/Al 1 1 Types TFK, THFK -- Interchangeable Trip GO-135B Complete Circuit Breaker Includes Line and Load Lugs MOLDED CASE CIRCUIT BREAKERS Adjustable Instantaneous Ampere Trip Ampere Range Rating Low High 3 Wire Size Three-Pole Standard Product Number Two-Pole, 480 Vac Max., 250 Vdc Max. 70 600 900 TFK224070WL 80 700 1000 TFK224080WL 90 600 900 TFK224090WL 100 600 1250 TFK224100WL 110 660 1250 TFK224110WL 125 600 1250 TFK224125WL 150 700 1500 TFK224150WL 175 800 1750 TFK224175WL 200 900 2000 TFK224200WL 225 1000 2250 TFK224225WL Three-Pole, 600 Vac Max., 250 Vdc Max. 70 600 900 TFK236070WL 80 700 1000 TFK236080WL 90 600 900 TFK236090WL 100 600 1250 TFK236100WL 110 660 1250 TFK236110WL 125 600 1250 TFK236125WL 150 700 1500 TFK236150WL 175 800 1750 TFK236175WL 200 900 2000 TFK236200WL 225 1000 2250 TFK236225WL 225 600 1400 -- Mag 1000 2250 -- Only Trip Unit Only Terminal Lugs for Front Connection (Copper/Aluminum) 2 Frame Only High-Break List Price Product Number List Price Use with Standard and Hi-Break Frames List Price Product Number $1122.00 $1122.00 $1122.00 $1122.00 $1122.00 $1122.00 $1122.00 $1122.00 $1122.00 $1122.00 THFK224070WL THFK224080WL THFK224090WL THFK224100WL THFK224110WL THFK224125WL THFK224150WL THFK224175WL THFK224200WL THFK224225WL $2315.00 $2315.00 $2315.00 $2315.00 $2315.00 $2315.00 $2315.00 $2315.00 $2315.00 $2315.00 TFK226T070 TFK226T080 TFK226T090 TFK226T100 TFK226T110 TFK226T125 TFK226T150 TFK226T175 TFK226T200 TFK226T225 $337.00 $337.00 TFK224F000 $753.00 $337.00 Standard $337.00 Frame $337.00 $337.00 $337.00 $337.00 THFK224F000 $1946.00 $337.00 Hi-Break $337.00 Frame $1407.00 $1407.00 $1407.00 $1407.00 $1407.00 $1407.00 $1407.00 $1407.00 $1407.00 $1407.00 -- -- THFK236070WL THFK236080WL THFK236090WL THFK236100WL THFK236110WL THFK236125WL THFK236150WL THFK236175WL THFK236200WL THFK236225WL -- -- $2787.00 $2787.00 $2787.00 $2787.00 $2787.00 $2787.00 $2787.00 $2787.00 $2787.00 $2787.00 -- -- TFK236T070 TFK236T080 TFK236T090 TFK236T100 TFK236T110 TFK236T125 TFK236T150 TFK236T175 TFK236T200 TFK236T225 TFK236TM12253 TFK236TM22253 $445.00 $445.00 $445.00 $445.00 $445.00 $445.00 $445.00 $445.00 $445.00 $445.00 $555.00 $555.00 TFK236F000 Standard Frame List Price Product Number (Order 1 line and 1 load per pole) List Price Wire Size TCAL24 $8.00 4-300 Cu/Al TCAL24 $8.00 4-300 Cu/Al $914.00 THFK236F000 $2294.00 Hi-Break Frame 1TC024 load end. Wire range #4-300 copper only. 2For optional lug see page 3-101. Accessories: See pages 3-85 to 3-104. 3-54 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers 125-400A Circuit Breakers Thermal-Magnetic Trip Q Line Circuit Breakers Types TJD Three-Pole TJD GO-135F TJD Lug-lug 240 Vac1 22 kAIC Ampere Rating Product Number List Price 250 300 350 400 400 Molded Case Switch TJD432250WL2 TJD432300WL2 TJD432350WL2 TJD432400WL2 TJD432Y4002 $1802.00 $1802.00 $1802.00 $1802.00 $1509.00 1Includes line and load lugs. For optional configurations, see page 3-21. 2TJD uses same accessories as J600 line. TJD not listed HACR. See page 3-4 for size and ratings. MOLDED CASE CIRCUIT BREAKERS TJD432300WL 3 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-55 Prices and data subject to change without notice Molded Case Circuit Breakers Industrial Circuit Breakers 125-600A Circuit Breakers Electronic Trip Spectra RMS SG600 Digital, Solid-State Spectra RMS Breakers SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S SGL, SGP UL Current Limiting UL/CSA: 400A, 600 Vac Max., IEC 947-2: 400A, 690 Vac Max. Rating Plug Frame UL 489 IC @480 Vac Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 125 150 175 200 225 250 300 350 400 380 455 530 605 680 755 905 1060 1210 1275 1530 1785 2040 2295 2550 3060 3570 4080 Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 65kA (240 Vac) Product Number List Price SRPG400A125 SRPG400A150 SRPG400A175 SRPG400A200 SRPG400A225 SRPG400A250 SRPG400A300 SRPG400A350 SRPG400A400 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor List Price 35kA Poles Product Number Product Number List Price 2 SGDA22AT04001 $1540.00 SGHA26AT0400 $1959.00 3 SGDA32AT04001 $1860.00 SGHA36AT0400 $2383.00 Product Number List Price Wire Range $28.00 (2) 2/0-500 Cu or (1) 8-600 Cu $42.00 (2) 2/0-500 Al or (1) 6-600 Al 2-pole lug kit TCLK2652 400 3-pole lug kit TCLK3652 SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S SGL, SGP UL Current Limiting UL/CSA: 400A, 600 Vac Max., IEC 947-2: 400A, 690 Vac Max. Rating Plug Frame UL 489 IC @480 Vac MOLDED CASE CIRCUIT BREAKERS Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 3 125 150 175 200 225 250 300 350 400 380 455 530 605 680 755 905 1060 1210 1275 1530 1785 2040 2295 2550 3060 3570 4080 Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 65kA Product Number List Price SRPG400A125 SRPG400A150 SRPG400A175 SRPG400A200 SRPG400A225 SRPG400A250 SRPG400A300 SRPG400A350 SRPG400A400 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor 100kA Poles Product Number List Price Product Number List Price 2 SGLA26AT0400 $2926.00 SGPA26AT0400 $3856.00 3 SGLA36AT0400 $3487.00 SGPA36AT0400 $4653.00 Product Number List Price Wire Range $28.00 (2) 2/0-500 Cu or (1) 8-600 Cu $42.00 (2) 2/0-500 Al or (1) 6-600 Al 2-pole lug kit TCLK2652 400 3-pole lug kit TCLK3652 SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S SGL, SGP UL Current Limiting UL/CSA: 600A, 600 Vac Max., IEC 947-2: 630A, 690 Vac Max. Rating Plug Frame UL 489 IC @480 Vac Adjustable Instantaneous Ampere Trip Ampere Range Rating Low High 250 300 350 400 450 500 600 765 915 1070 1220 1375 1525 1830 2530 3035 3545 4050 4555 5060 6075 Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 35kA Product Number List Price SRPG600A250 SRPG600A300 SRPG600A350 SRPG600A400 SRPG600A450 SRPG600A500 SRPG600A600 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor 65kA Poles Product Number List Price Product Number List Price 2 SGHA26AT0600 $2663.00 SGLA26AT0600 $3545.00 3 SGHA36AT0600 $3354.00 SGLA36AT0600 $4270.00 Product Number List Price Wire Range $28.00 (2) 2/0-500 Cu or (1) 8-600 Cu 2-pole lug kit TCLK2652 600 3-pole lug kit TCLK3652 $42.00 (2) 2/0-500 Al or (1) 6-600 Al 1Rated 240 Vac max. 2Order one kit for either line or load end; two kits required for both. 3-56 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers 125-600A Circuit Breakers Electronic Trip Spectra RMS SG600 Digital, Solid-State Spectra RMS Breakers SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S SGL, SGP UL Current Limiting UL/CSA: 600A, 600 Vac Max., IEC 947-2: 630A, 690 Vac Max. Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 250 300 350 400 450 500 600 765 915 1070 1220 1375 1525 1830 2530 3035 3545 4050 4555 5060 6075 100kA Product Number List Price SRPG600A250 SRPG600A300 SRPG600A350 SRPG600A400 SRPG600A450 SRPG600A500 SRPG600A600 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor Poles Product Number List Price 2 SGPA26AT0600 $4607.00 3 SGPA36AT0600 $5548.00 Product Number List Price Wire Range $28.00 (2) 2/0-500 Cu or (1) 8-600 Cu 2-pole lug kit TCLK2651 600 3-pole lug kit TCLK3651 $42.00 (2) 2/0-500 Al or (1) 6-600 Al 1Order one kit for either line or load end; two kits required for both. SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S SGL, SGP UL Current Limiting 100% UL Rated, 3-Pole: 400A, 600 Vac Max.; IEC 947-2: 400A, 690 Vac Max. Frame UL 489 IC @480 Vac Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 125 150 175 200 225 250 300 350 400 380 455 530 605 680 755 905 1060 1210 1275 1530 1785 2040 2295 2550 3060 3570 4080 Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 35kAIC Product Number List Price SRPG400A125 SRPG400A150 SRPG400A175 SRPG400A200 SRPG400A225 SRPG400A250 SRPG400A300 SRPG400A350 SRPG400A400 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor Poles Product Number 65kAIC List Price Product Number List Price Product Number List Price Wire Range (2) 2/0-500 Cu or (1) 8-600 Cu 400 3 SGHH36AT0400 $4381.00 SGLL36AT0400 $5501.00 TCLK365 $42.00 (2) 2/0-500 Al or (1) 6-600 Al SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S SGL, SGP UL Current Limiting 100% UL Rated, 3-Pole: 400A, 600 Vac Max.; IEC 947-2: 400A, 690 Vac Max. Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 125 150 175 200 225 250 300 350 400 380 455 530 605 680 755 905 1060 1210 1275 1530 1785 2040 2295 2550 3060 3570 4080 100kAIC Product Number List Price SRPG400A125 SRPG400A150 SRPG400A175 SRPG400A200 SRPG400A225 SRPG400A250 SRPG400A300 SRPG400A350 SRPG400A400 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor Poles Product Number List Price Product Number List Price Wire Range (2) 2/0-500 Cu or (1) 8-600 Cu 400 3 SGPP36AT0400 $6049.00 TCLK365 $42.00 (2) 2/0-500 Al or (1) 6-600 Al Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-57 Prices and data subject to change without notice MOLDED CASE CIRCUIT BREAKERS Rating Plug 3 Molded Case Circuit Breakers Industrial Circuit Breakers 125-600A Circuit Breakers Electronic Trip Spectra RMS SG600 Digital, Solid-State Spectra RMS Breakers SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S SGL, SGP UL Current Limiting 100% UL Rated, 3-Pole: 600A, 600 Vac Max.; IEC 947-2: 630A, 690 Vac Max. Rating Plug Frame UL 489 IC @480 Vac Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 250 300 350 400 450 500 600 765 915 1070 1220 1375 1525 1830 2530 3035 3545 4050 4555 5060 6075 Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 35kAIC Product Number List Price SRPG600A250 SRPG600A300 SRPG600A350 SRPG600A400 SRPG600A450 SRPG600A500 SRPG600A600 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor Poles Product Number 65kAIC List Price Product Number List Price Product Number List Price Wire Range (2) 2/0-500 Cu or (1) 8-600 Cu 600 3 SGHH36AT0600 $5451.00 SGLL36AT0600 $6783.00 TCLK365 $42.00 (2) 2/0-500 Al (1) 6-600 Al SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S SGL, SGP UL Current Limiting 100% UL Rated, 3-Pole: 600A, 600 Vac Max.; IEC 947-2: 630A, 690 Vac Max. Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac MOLDED CASE CIRCUIT BREAKERS Adjustable Instantaneous Ampere Trip Ampere Range Rating Low High 250 300 350 400 450 500 600 765 915 1070 1220 1375 1525 1830 2530 3035 3545 4050 4555 5060 6075 100kAIC Product Number List Price SRPG600A250 SRPG600A300 SRPG600A350 SRPG600A400 SRPG600A450 SRPG600A500 SRPG600A600 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor Poles Product Number List Price Product Number List Price Wire Range (2) 2/0-500 Cu or (1) 8-600 Cu 600 3 SGPP36AT0600 $7212.00 TCLK365 $42.00 (2) 2/0-500 Al or (1) 6-600 Al 3 3-58 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers 60-600A Circuit Breakers Electronic Trip Spectra RMS SG600 with MicroVersaTrip Plus and PM MicroVersaTrip Plus, Standard UL Rated GO-135S SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600 Vac Max., IEC 947-2: 630A, 690 Vac Max. Frame Current Sensor 150 400 600 Terminal Lugs for Front connection (Cu/Al) IC @480 Vac, UL 489 IC @480 Vac, UL 489 Trip Function 35kA Product Number List Price 65kA Product Number List Price 100kA Product Number List Price LIT LSIT LIGT1 LSIGT1 LIT-CP2 LSIT-CP2 LIT LSIT LIGT1 LSIGT1 LIT-CP2 LSIT-CP2 LIT LSIT LIGT1 LSIGT1 LIT-CP2 LSIT-CP2 SGHB36BA0150 SGHB36BB0150 SGHB36BC0150 SGHB36BD0150 SGHB36BE0150 SGHB36BF0150 SGHB36BA0400 SGHB36BB0400 SGHB36BC0400 SGHB36BD0400 SGHB36BE0400 SGHB36BF0400 SGHB36BA0600 SGHB36BB0600 SGHB36BC0600 SGHB36BD0600 SGHB36BE0600 SGHB36BF0600 $2597.00 $3962.00 $3807.00 $5172.00 $2897.00 $4262.00 $2597.00 $3962.00 $3807.00 $5172.00 $2897.00 $4262.00 $3551.00 $4916.00 $4761.00 $6126.00 $3851.00 $5216.00 SGLB36BA0150 SGLB36BB0150 SGLB36BC0150 SGLB36BD0150 SGLB36BE0150 SGLB36BF0150 SGLB36BA0400 SGLB36BB0400 SGLB36BC0400 SGLB36BD0400 SGLB36BE0400 SGLB36BF0400 SGLB36BA0600 SGLB36BB0600 SGLB36BC0600 SGLB36BD0600 SGLB36BE0600 SGLB36BF0600 $3752.00 $5117.00 $4962.00 $6327.00 $4052.00 $5417.00 $3752.00 $5117.00 $4962.00 $6327.00 $4052.00 $5417.00 $4505.00 $5870.00 $5715.00 $7080.00 $4805.00 $6170.00 SGPB36BA0150 SGPB36BB0150 SGPB36BC0150 SGPB36BD0150 SGPB36BE0150 SGPB36BF0150 SGPB36BA0400 SGPB36BB0400 SGPB36BC0400 SGPB36BD0400 SGPB36BE0400 SGPB36BF0400 SGPB36BA0600 SGPB36BB0600 SGPB36BC0600 SGPB36BD0600 SGPB36BE0600 SGPB36BF0600 $4932.00 $6297.00 $6142.00 $7507.00 $5232.00 $6597.00 $4932.00 $6297.00 $6142.00 $7507.00 $5232.00 $6597.00 $5880.00 $7245.00 $7090.00 $8455.00 $6180.00 $7545.00 Product Number 3-Pole lug kit TCLK3653 List Price Wire Range $42.00 (2) 2/0-500 Cu or (1) 8-600 Cu (2) 2/0-500 Al or (1) 6-600 Al MicroVersaTrip Plus, 100% UL Rate 4 GO-135S SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600 Vac Max., IEC 947-2: 630A, 690 Vac Max. Frame IC @480 Vac, UL 489 Current Sensor 150 400 600 Terminal Lugs for Front connection (Cu/Al) IC @480 Vac, UL 489 IC @480 Vac, UL 489 Trip Function 35kA Product Number List Price 65kA Product Number List Price 100kA Product Number List Price LIT LSIT LIGT1 LSIGT1 LIT-CP2 LSIT-CP2 LIT LSIT LIGT1 LSIGT1 LIT-CP2 LSIT-CP2 LIT LSIT LIGT3 LSIGT3 LIT-CP4 LSIT-CP4 SGHH36BA0150 SGHH36BB0150 SGHH36BC0150 SGHH36BD0150 SGHH36BE0150 SGHH36BF0150 SGHH36BA0400 SGHH36BB0400 SGHH36BC0400 SGHH36BD0400 SGHH36BE0400 SGHH36BF0400 SGHH36BA0600 SGHH36BB0600 SGHH36BC0600 SGHH36BD0600 SGHH36BE0600 SGHH36BF0600 $4774.00 $6139.00 $5984.00 $7349.00 $5074.00 $6439.00 $4774.00 $6139.00 $5984.00 $7349.00 $5074.00 $6439.00 $5771.00 $7136.00 $6981.00 $8346.00 $6071.00 $7436.00 SGLL36BA0150 SGLL36BB0150 SGLL36BC0150 SGLL36BD0150 SGLL36BE0150 SGLL36BF0150 SGLL36BA0400 SGLL36BB0400 SGLL36BC0400 SGLL36BD0400 SGLL36BE0400 SGLL36BF0400 SGLL36BA0600 SGLL36BB0600 SGLL36BC0600 SGLL36BD0600 SGLL36BE0600 SGLL36BF0600 $5919.00 $7284.00 $7129.00 $8494.00 $6219.00 $7584.00 $5919.00 $7284.00 $7129.00 $8494.00 $6219.00 $7584.00 $7155.00 $8520.00 $8365.00 $9730.00 $7455.00 $8820.00 SGPP36BA0150 SGPP36BB0150 SGPP36BC0150 SGPP36BD0150 SGPP36BE0150 SGPP36BF0150 SGPP36BA0400 SGPP36BB0400 SGPP36BC0400 SGPP36BD0400 SGPP36BE0400 SGPP36BF0400 SGPP36BA0600 SGPP36BB0600 SGPP36BC0600 SGPP36BD0600 SGPP36BE0600 SGPP36BF0600 $6412.00 $7777.00 $7622.00 $8987.00 $6712.00 $8077.00 $6412.00 $7777.00 $7622.00 $8987.00 $6712.00 $8077.00 $7644.00 $9009.00 $8854.00 $10219.00 $7944.00 $9309.00 Product Number 3-Pole lug kit TCLK3653 List Price Wire Range $42.00 (2) 2/0-500 Al or (1) 6-600 Al (2) 2/0-500 Cu or (1) 8-600 Cu 1For grounded neutral systems (1**/3w or 3**4w) a neutral current sensor is required. Refer to page 3-109. 2For +24 Vdc Control Power Accessories refer to pages 3-106 to 3-109. 3Order one kit for either line or load end; two kits required for both. 4100% UL rated supplied with back-connected assembly which increases breaker depth. Refer to outline drawing for details. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-59 Prices and data subject to change without notice MOLDED CASE CIRCUIT BREAKERS IC @480 Vac, UL 489 3 Molded Case Circuit Breakers Industrial Circuit Breakers 60-600A Circuit Breakers Electronic Trip Spectra RMS with MicroVersaTrip PM Trip Units 1 MicroVersaTrip PM, Standard UL Rated (No Protective Relays) GO-135S SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600 Vac Max., IEC 947-2: 630A, 690 Vac Max. Frame IC @480 Vac, UL 489 Current Sensor 150 400 600 Terminal Lugs for Front connection (Cu/Al) IC @480 Vac, UL 489 IC @480 Vac, UL 489 Trip Function 35kA Product Number List Price 65kA Product Number List Price 100kA Product Number List Price LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 SGHB36CA0150 SGHB36CB0150 SGHB36CC0150 SGHB36CD0150 SGHB36CA0400 SGHB36CB0400 SGHB36CC0400 SGHB36CD0400 SGHB36CA0600 SGHB36CB0600 SGHB36CC0600 SGHB36CD0600 $3797.00 $5162.00 $5007.00 $6372.00 $3797.00 $5162.00 $5007.00 $6372.00 $4751.00 $6116.00 $5961.00 $7326.00 SGLB36CA0150 SGLB36CB0150 SGLB36CC0150 SGLB36CD0150 SGLB36CA0400 SGLB36CB0400 SGLB36CC0400 SGLB36CD0400 SGLB36CA0600 SGLB36CB0600 SGLB36CC0600 SGLB36CD0600 $4952.00 $6317.00 $6162.00 $7527.00 $4952.00 $6317.00 $6162.00 $7527.00 $5705.00 $7070.00 $6915.00 $8280.00 SGPB36CA0150 SGPB36CB0150 SGPB36CC0150 SGPB36CD0150 SGPB36CA0400 SGPB36CB0400 SGPB36CC0400 SGPB36CD0400 SGPB36CA0600 SGPB36CB0600 SGPB36CC0600 SGPB36CD0600 $6132.00 $7497.00 $7342.00 $8707.00 $6132.00 $7497.00 $7342.00 $8707.00 $7080.00 $8445.00 $8290.00 $9655.00 Product Number List Price Wire Range (2) 2/0-500 Cu or (1) 8-600 Cu 3-Pole lug kit TCLK3653 $42.00 (2) 2/0-500 Al or (1) 6-600 Al MicroVersaTrip PM, 100% UL Rated 4 (No Protective Relays) GO-135S SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600 Vac Max., IEC 947-2: 630A, 690 Vac Max. Frame IC @480 Vac, UL 489 Current Sensor MOLDED CASE CIRCUIT BREAKERS 150 3 400 600 Trip Function 35kA Product Number List Price 65kA Product Number LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 SGHH36CA0150 SGHH36CB0150 SGHH36CC0150 SGHH36CD0150 SGHH36CA0400 SGHH36CB0400 SGHH36CC0400 SGHH36CD0400 SGHH36CA0600 SGHH36CB0600 SGHH36CC0600 SGHH36CD0600 $5974.00 $7339.00 $7184.00 $8549.00 $5974.00 $7339.00 $7184.00 $8549.00 $6971.00 $8336.00 $8181.00 $9546.00 SGLL36CA0150 SGLL36CB0150 SGLL36CC0150 SGLL36CD0150 SGLL36CA0400 SGLL36CB0400 SGLL36CC0400 SGLL36CD0400 SGLL36CA0600 SGLL36CB0600 SGLL36CC0600 SGLL36CD0600 MicroVersaTrip Plus and PM Rating Plug Selection -- All Plugs List Price, $106.00 Circuit Breaker Frame Sensor Rating Rating Plug Rating (Amperes) 150 60 80 100 125 150 150 200 225 250 300 350 400 300 400 450 500 600 400 SGHB, SGHH, SGLB, SGLL, SGPB, SGPP 600 Terminal Lugs for Front connection (Cu/Al) IC @480 Vac, UL 489 List Price $7119.00 $8484.00 $8329.00 $9694.00 $7119.00 $8484.00 $8329.00 $9694.00 $8355.00 $9720.00 $9565.00 $10930.00 IC @480 Vac, UL 489 100kA Product Number List Price SGPP36CA0150 SGPP36CB0150 SGPP36CC0150 SGPP36CD0150 SGPP36CA0400 SGPP36CB0400 SGPP36CC0400 SGPP36CD0400 SGPP36CA0600 SGPP36CB0600 SGPP36CC0600 SGPP36CD0600 $7612.00 $8977.00 $8822.00 $10187.00 $7612.00 $8977.00 $8822.00 $10187.00 $8844.00 $10209.00 $10054.00 $11419.00 Product Number List Price Wire Range (2) 2/0-500 Cu or (1) 8-600 Cu 3-Pole lug kit TCLK3653 $42.00 (2) 2/0-500 Al or (1) 6-600 Al GO-135S Rating Plug Product No. SRPG150B60 SRPG150B80 SRPG150B100 SRPG150B125 SRPG150B150 SRPG400B150 SRPG400B200 SRPG400B225 SRPG400B250 SRPG400B300 SRPG400B350 SRPG400B400 SRPG600B300 SRPG600B400 SRPG600B450 SRPG600B500 SRPG600B600 1MicroVersaTrip PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages 3-106 to 3-109. 2For grounded neutral systems (1**/3w or 3**4w) a neutral current sensor is required. Refer to page 3-109. 3Order one kit for either line or load end; two kits required for both. 4100% UL rated supplied with back-connected assembly which increases breaker depth. Refer to outline drawing for details. 3-60 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers 60-600A Circuit Breakers Electronic Trip Spectra RMS with MicroVersaTrip PM Trip Units 1 MicroVersaTrip PM, Standard UL Rated (With Protective Relaying) GO-135S SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600 Vac Max., IEC 947-2: 630A, 690 Vac Max. Frame IC @480 Vac, UL 489 Current Sensor 150 400 600 Terminal Lugs for Front connection (Cu/Al) IC @480 Vac, UL 489 IC @480 Vac, UL 489 Trip Function 35kA Product Number List Price 65kA Product Number List Price 100kA Product Number List Price LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 SGHB36DA0150 SGHB36DB0150 SGHB36DC0150 SGHB36DD0150 SGHB36DA0400 SGHB36DB0400 SGHB36DC0400 SGHB36DD0400 SGHB36DA0600 SGHB36DB0600 SGHB36DC0600 SGHB36DD0600 $4997.00 $6362.00 $6207.00 $7572.00 $4997.00 $6362.00 $6207.00 $7572.00 $5951.00 $7316.00 $7161.00 $8526.00 SGLB36DA0150 SGLB36DB0150 SGLB36DC0150 SGLB36DD0150 SGLB36DA0400 SGLB36DB0400 SGLB36DC0400 SGLB36DD0400 SGLB36DA0600 SGLB36DB0600 SGLB36DC0600 SGLB36DD0600 $6152.00 $7517.00 $7362.00 $8727.00 $6152.00 $7517.00 $7362.00 $8727.00 $6905.00 $8270.00 $8115.00 $9480.00 SGPB36DA0150 SGPB36DB0150 SGPB36DC0150 SGPB36DD0150 SGPB36DA0400 SGPB36DB0400 SGPB36DC0400 SGPB36DD0400 SGPB36DA0600 SGPB36DB0600 SGPB36DC0600 SGPB36DD0600 $7332.00 $8697.00 $8542.00 $9907.00 $7332.00 $8697.00 $8542.00 $9907.00 $8280.00 $9645.00 $9490.00 $10855.00 Product Number List Price Wire Range (2) 2/0-500 Cu or (1) 8-600 Cu 3-Pole lug kit TCLK3653 $42.00 (2) 2/0-500 Al or (1)6-600 Al MicroVersaTrip PM, 100% UL Rated 4 (With Protective Relays) GO-135S SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600 Vac Max., IEC 947-2: 630A, 690 Vac Max. Frame Current Sensor 150 400 600 Trip Function 35kA Product Number List Price 65kA Product Number LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 SGHH36DA0150 SGHH36DB0150 SGHH36DC0150 SGHH36DD0150 SGHH36DA0400 SGHH36DB0400 SGHH36DC0400 SGHH36DD0400 SGHH36DA0600 SGHH36DB0600 SGHH36DC0600 SGHH36DD0600 $7174.00 $8539.00 $8384.00 $9749.00 $7174.00 $8539.00 $8384.00 $9749.00 $8171.00 $9536.00 $9381.00 $10746.00 SGLL36DA0150 SGLL36DB0150 SGLL36DC0150 SGLL36DD0150 SGLL36DA0400 SGLL36DB0400 SGLL36DC0400 SGLL36DD0400 SGLL36DA0600 SGLL36DB0600 SGLL36DC0600 SGLL36DD0600 MicroVersaTrip Plus and PM Rating Plug Selection -- All Plugs List Price, $106.00 Circuit Breaker Frame Sensor Rating Rating Plug Rating (Amperes) 150 60 80 100 125 150 150 200 225 250 300 350 400 300 400 450 500 600 400 SGHB, SGHH, SGLB, SGLL, SGPB, SGPP 600 Terminal Lugs for Front connection (Cu/Al) IC @480 Vac, UL 489 List Price $8319.00 $9684.00 $9529.00 $10894.00 $8319.00 $9684.00 $9529.00 $10894.00 $9555.00 $10920.00 $10765.00 $12130.00 IC @480 Vac, UL 489 100kA Product Number List Price SGPP36DA0150 SGPP36DB0150 SGPP36DC0150 SGPP36DD0150 SGPP36DA0400 SGPP36DB0400 SGPP36DC0400 SGPP36DD0400 SGPP36DA0600 SGPP36DB0600 SGPP36DC0600 SGPP36DD0600 $8812.00 $10177.00 $10022.00 $11387.00 $8812.00 $10177.00 $10022.00 $11387.00 $10044.00 $11409.00 $11254.00 $12619.00 Product Number List Price Wire Range (2) 2/0-500 Cu or (1) 6-600 Cu 3-Pole lug kit TCLK3653 $42.00 (2) 2/0-500 Al or (1) 8-600 Al GO-135S Rating Plug Product No. 3 SRPG150B60 SRPG150B80 SRPG150B100 SRPG150B125 SRPG150B150 SRPG400B150 SRPG400B200 SRPG400B225 SRPG400B250 SRPG400B300 SRPG400B350 SRPG400B400 SRPG600B300 SRPG600B400 SRPG600B450 SRPG600B500 SRPG600B600 1MicroVersaTrip PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages 3-106 to 3-109. 2For grounded neutral systems (1**/3w or 3**4w) a neutral current sensor is required. Refer to page 3-109. 3Order one kit for either line or load end; two kits required for both. 4100% UL rated supplied with back-connected assembly which increases breaker depth. Refer to outline drawing for details. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 MOLDED CASE CIRCUIT BREAKERS IC @480 Vac, UL 489 www.geindustrial.com BuyLog Catalog 3-61 Prices and data subject to change without notice Molded Case Circuit Breakers Industrial Circuit Breakers 125-600A Circuit Breakers Thermal-Magnetic Trip J600 Line Circuit Breakers Types TJJ, TJK, THJK TYPE TJK Type TJJ Noninterchangeable Trip (includes Line and Load Lugs), suitable for reverse feed GO-135B Frame Ampere Rating 125 150 175 200 225 250 300 350 400 2-Pole, 400 Ampere Frame 600 Vac, 250 Vdc Adjustable Instantaneous Trip Ampere Range 3-Pole, 400 Ampere Frame 600 Vac Low High Product Number List Price Product Number List Price 375 450 525 600 675 750 900 1050 1200 1250 1500 1750 2000 2250 2500 3000 3500 4000 TJJ426125WL TJJ426150WL TJJ426175WL TJJ426200WL TJJ426225WL TJJ426250WL TJJ426300WL TJJ426350WL TJJ426400WL $2118.00 $2118.00 $2118.00 $2118.00 $2118.00 $2118.00 $2118.00 $2118.00 $2118.00 TJJ436125WL TJJ436150WL TJJ436175WL TJJ436200WL TJJ436225WL TJJ436250WL TJJ436300WL TJJ436350WL TJJ436400WL $2573.00 $2573.00 $2573.00 $2573.00 $2573.00 $2573.00 $2573.00 $2573.00 $2573.00 Terminal Lugs for Front Connection (Cu/Al) Copper/ Aluminum Lugs Wire Size TCAL432 Included in price of breaker (1) 6-600 or (2) 2/0-250 Cu/Al Types TJK, THJK -- Interchangeable Trip, not suitable for reverse feed GO-135B MOLDED CASE CIRCUIT BREAKERS Complete Circuit Breaker Includes Line and Load Lugs 3 Adjustable Instantaneous Ampere Trip Ampere Range Standard Rating Low High Product Number List Price 400A Frame--Two-Pole 125 375 1250 TJK426125WL 150 450 1500 TJK426150WL 175 525 1750 TJK426175WL 200 600 2000 TJK426200WL 225 675 2250 TJK426225WL 250 750 2500 TJK426250WL 300 900 3000 TJK426300WL 350 1050 3500 TJK426350WL 400 1200 4000 TJK426400WL $2118.00 $2118.00 $2118.00 $2118.00 $2118.00 $2118.00 $2118.00 $2118.00 $2118.00 THJK426125WL THJK426150WL THJK426175WL THJK426200WL THJK426225WL THJK426250WL THJK426300WL THJK426350WL THJK426400WL $3085.00 $3085.00 $3085.00 $3085.00 $3085.00 $3085.00 $3085.00 $3085.00 $3085.00 400A Frame--Three-Pole 125 375 1250 TJK436125WL 150 450 1500 TJK436150WL 175 525 1750 TJK436175WL 200 600 2000 TJK436200WL 225 675 2250 TJK436225WL 250 750 2500 TJK436250WL 300 900 3000 TJK436300WL 350 1050 3500 TJK436350WL 400 1200 4000 TJK436400WL 400 600 2000 -- Mag 1200 4000 -- Only 350 1000 -- $2573.00 $2573.00 $2573.00 $2573.00 $2573.00 $2573.00 $2573.00 $2573.00 $2573.00 -- -- -- THJK436125WL THJK436150WL THJK436175WL THJK436200WL THJK436225WL THJK436250WL THJK436300WL THJK436350WL THJK436400WL -- -- -- $3675.00 $3675.00 $3675.00 $3675.00 $3675.00 $3675.00 $3675.00 $3675.00 $3675.00 -- -- -- Hi-Break Product Number List Price Terminal Lugs for Front Connection (Cu/Al)1 Frame Only Product Number List Price TJK426F000 Standard Frame $1598.00 THJK426F000 $2565.00 Hi-Break TJK436F000 Standard Frame $2025.00 THJK436F000 $3127.00 Hi-Break Trip Unit Only. Use with Standard and Hi-Break Frames List Price TJK426T125 TJK426T150 TJK426T175 TJK426T200 TJK426T225 TJK426T250 TJK426T300 TJK426T350 TJK426T400 $464.00 $464.00 $464.00 $464.00 $464.00 $464.00 $464.00 $464.00 $464.00 TJK436T125 TJK436T150 TJK436T175 TJK436T200 TJK436T225 TJK436T250 TJK436T300 TJK436T350 TJK436T400 TJK436TM14003 TJK436TM24003 TJK436TM34003 $464.00 $464.00 $464.00 $464.00 $464.00 $464.00 $464.00 $464.00 $464.00 $558.00 $558.00 $558.00 Product Number (Order 2 per pole) List Price TCAL432 $14.00 (1) 6-600 or (2) 2/0-250 Cu/Al TCAL432 $14.00 (1) 6-600 or (2) 2/0-250 Cu/Al Wire Size 1For optional lugs, see page 3-101. 2Not UL listed. 3Alternate lug for 750 kcmil Cu/Al cable, Product Number TCAL47 List Price $26.00, GO-135B. Accessories: See pages 3-85 to 3-104. 3-62 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers 125-600A Circuit Breakers Thermal-Magnetic Trip J600 Line Circuit Breakers Types TJJ, TJK, THJK Types TJK, THJK -- Interchangeable Trip GO-135S Complete Circuit Breaker Includes Line and Load Lugs Adjustable Instantaneous Ampere Trip Ampere Range Standard Rating Low High Product Number 600A Frame--Two-Pole 250 750 2500 TJK626250WL 300 900 3000 TJK626300WL 350 1050 3500 TJK626350WL 400 1200 4000 TJK626400WL 450 1350 4500 TJK626450WL 500 1500 5000 TJK626500WL 600 1800 6000 TJK626600WL 600A Frame--Three-Pole 250 750 2500 TJK636250WL 300 900 3000 TJK636300WL 350 1050 3500 TJK636350WL 400 1200 4000 TJK636400WL 450 1350 4500 TJK636450WL 500 1500 5000 TJK636500WL 600 1800 600 TJK636600WL 600 6000 2000 -- Mag Only 1800 6000 -- List Price Hi-Break Product Number List Price $2812.00 THJK626250WL $2812.00 THJK626300WL $2812.00 THJK626350WL $2812.00 THJK626400WL $2848.00 THJK626450WL $2848.00 THJK626500WL $2848.00 THJK626600WL $3704.00 $3704.00 $3704.00 $3704.00 $3740.00 $3740.00 $3740.00 $3539.00 $3539.00 $3539.00 $3539.00 $3593.00 $3593.00 $3593.00 -- $4457.00 $4457.00 $4457.00 $4457.00 $4511.00 $4511.00 $4511.00 -- -- THJK636250WL THJK636300WL THJK636350WL THJK636400WL THJK636450WL THJK636500WL THJK636600WL -- -- Terminal Lugs for Front Connection (Cu/Al)1 Frame Only Product Number List Price TJK626F000 $1535.00 Standard Frame THJK626F000 Hi-Break $2427.00 Frame TJK636F000 $2234.00 Standard Frame THJK636F000 Hi-Break $3152.00 Frame -- Trip Unit Only. Use with Standard and Hi-Break Frames List Price Product Number (Order 2 per pole) List Price TJK626T250 TJK626T300 TJK626T350 TJK626T400 TJK626T450 TJK626T500 TJK626T600 $1221.00 $1221.00 $1221.00 $1221.00 $1221.00 $1221.00 $1221.00 TCAL432 $14.00 TCAL63 $23.00 TJK636T250 TJK636T300 TJK636T350 TJK636T400 TJK636T450 TJK636T500 TJK636T600 TJK636TM16003 $1221.00 $1221.00 $1221.00 $1221.00 $1221.00 $1221.00 $1221.00 $1465.00 TCAL432 $14.00 TCAL63 $23.00 Wire Size (1) 6-600 or (2) 2/0-250 Cu/Al (2) 4/0-350 Cu or (2) 300-500 Al (1) 6-600 or (2) 2/0-250 Cu/Al (2) 4/0-350 Cu or (2) 300-500 Al TJK636TM26003 $1465.00 1For optional lugs, see page 3-101. 2Alternate lug for 750 kcmil Cu/Al cable, Product Number TCAL47 List Price $26.00, GO-135B. 3Not UL listed. MOLDED CASE CIRCUIT BREAKERS Accessories: See pages 3-85 to 3-104. 3 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-63 Prices and data subject to change without notice Molded Case Circuit Breakers Industrial Circuit Breakers 300-1200A Circuit Breakers Electronic Trip Spectra RMS SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S UL/CSA: 800A, 600 Vac Max., IEC 947-2:800A 690 Vac Max. Rating Plug Frame UL 489 IC @480 Vac Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 300 400 500 600 700 800 940 1255 1570 1875 2155 2440 3015 4015 5020 6195 7420 8705 Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 50kA Product Number List Price Current Sensor SRPK800A300 SRPK800A400 SRPK800A500 SRPK800A600 SRPK800A700 SRPK800A800 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 800 65kA Poles Product Number List Price Product Number List Price 2 SKHA26AT0800 $3377.00 SKLA26AT0800 $4301.00 3 SKHA36AT0800 $4323.00 SKLA36AT0800 Product Number List Price TCAL81 $47.00 Wire Range (3) 3/0-500 Cu $5234.00 (3) 3/0-500 Al SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S UL/CSA: 800A, 600 Vac Max., IEC 947-2:800A 690 Vac Max. Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac Adjustable Instantaneous Ampere Trip Ampere Range Rating Low High 300 400 500 600 700 800 940 1255 1570 1875 2155 2440 3015 4015 5020 6195 7420 8705 100kA Product Number List Price Current Sensor SRPK800A300 SRPK800A400 SRPK800A500 SRPK800A600 SRPK800A700 SRPK800A800 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 800 Poles Product Number List Price 2 SKPA26AT0800 $6746.00 3 SKPA36AT0800 Product Number List Price TCAL81 $47.00 (3) 3/0-500 Cu $8240.00 (3) 3/0-500 Al MOLDED CASE CIRCUIT BREAKERS SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 3 Wire Range GO-135S UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. Rating Plug Frame UL 489 IC @480 Vac Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 600 700 800 1000 1200 1825 2125 2430 3040 3650 Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 35kA Product Number List Price 6110 SRPK1200A600 $106.00 7125 SRPK1200A700 $106.00 8145 SRPK1200A800 $106.00 10180 SRPK1200A1000 $106.00 12215 SRPK1200A1200 $106.00 Current Sensor 65kA Poles Product Number List Price Product Number List Price 2 SKHA26AT1200 $7057.00 SKLA26AT1200 $7958.00 1200 3 SKHA36AT1200 $7679.00 SKLA36AT1200 Product Number List Price TCAL125 $76.00 Wire Range (4) 250-500 Cu1 $8586.00 (4) 250-350 Al SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 600 700 800 1000 1200 1825 2125 2430 3040 3650 100kA Product Number List Price 6110 SRPK1200A600 $106.00 7125 SRPK1200A700 $106.00 8145 SRPK1200A800 $106.00 10180 SRPK1200A1000 $106.00 12215 SRPK1200A1200 $106.00 Current Sensor Poles Product Number List Price 2 SKPA26AT1200 $10136.00 1200 3 SKPA36AT1200 Product Number List Price TCAL125 $76.00 Wire Range (4) 250-500 Cu1 $11183.00 (4) 250-350 Al 1Suitable for 500 kcmil copper for voltage drop consideration, 1200 ampere max. rating. 3-64 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers 300-1200A Circuit Breakers Electronic Trip Spectra RMS SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S 100% UL Rated, 3-Pole: 800A, 600 Vac Max.; IEC 947-2: 800A, 690 Vac Max. Rating Plug Frame UL 489 IC @480 Vac Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 300 400 500 600 700 800 940 1255 1570 1875 2155 2440 3015 4015 5020 6195 7420 8705 Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 50kA Product Number List Price SRPK800A300 SRPK800A400 SRPK800A500 SRPK800A600 SRPK800A700 SRPK800A800 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor 800 65kA Poles Product Number List Price Product Number List Price Product Number List Price 3 SKHH36AT0800 $7514.00 SKLL36AT0800 $9325.00 TCAL81 $47.00 Wire Range (3) 3/0-500 Cu (3) 3/0-500 Al SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S 100% UL Rated, 3-Pole: 800A, 600 Vac Max.; IEC 947-2: 800A, 690 Vac Max. Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 300 400 500 600 700 800 940 1255 1570 1875 2155 2440 3015 4015 5020 6195 7420 8705 100kA Product Number List Price SRPK800A300 SRPK800A400 SRPK800A500 SRPK800A600 SRPK800A700 SRPK800A800 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor 800 Poles Product Number List Price Product Number List Price 3 SKPP36AT0800 $10712.00 TCAL81 $47.00 Wire Range (3) 3/0-500 Cu (3) 3/0-500 Al SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S 100% UL Rated, 3-Pole: 1000A, 600 Vac Max.; IEC 947-2: 1000A, 690 Vac Max. Rating Plug Frame UL 489 IC @480 Vac Adjustable Instantaneous Ampere Trip Ampere Range Rating Low High 600 700 800 1000 1200 1825 2125 2430 3040 3650 Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac 50kA Product Number List Price 6110 SRPK1200A600 $106.00 7125 SRPK1200A700 $106.00 8145 SRPK1200A800 $106.00 10180 SRPK1200A1000 $106.00 12215 SRPL12000A1200 $106.00 Current Sensor 1200 65kA Poles Product Number List Price Product Number List Price Product Number List Price 3 SKHH36AT1000 $11051.00 SKLL36AT1000 $13678.00 TCAL125 $76.00 3 SKHH36AT12001 $11450.00 SKLL36AT12001 $14250.00 Wire Range (4) 250-500 Cu2 (4) 250-350 Al 3 SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 GO-135S 100% UL Rated, 3-Pole: 1000A, 600 Vac Max.; IEC 947-2: 1000A, 690 Vac Max. Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 IC @480 Vac Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High 600 700 800 1000 1200 1825 2125 2430 3040 3650 100kA Product Number List Price 6110 SRPK1200A600 $106.00 7125 SRPK1200A700 $106.00 8145 SRPK1200A800 $106.00 10180 SRPK1200A1000 $106.00 12215 SRKP1200A1200 $106.00 Current Sensor 1200 Poles Product Number List Price Product Number List Price 3 SKPP36AT1000 $14538.00 TCAL125 $76.00 3 SKPP36AT12001 $15235.00 Wire Range (4) 250-500 Cu2 (4) 250-350 Al 1100% UL rated SK1200 supplied with back-connected assembly which increases breaker depth. Refer to outline drawings for details. 2Suitable for 500 kcmil copper for voltage drop consideration, 1200A max. rating. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 MOLDED CASE CIRCUIT BREAKERS Adjustable Instantaneous Trip Ampere Range Ampere Rating Low High www.geindustrial.com BuyLog Catalog 3-65 Prices and data subject to change without notice Molded Case Circuit Breakers Industrial Circuit Breakers 300-1200A Circuit Breakers Electronic Trip Spectra RMS SK1200 with MicroVersaTrip Plus and PM MicroVersaTrip Plus, Standard UL Rated GO-135S SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 3-Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only) Frame IC @480 Vac, UL 489 Current Sensor 800 1200 Trip Function 50kA Product Number LIT LSIT LIGT1 LSIGT1 LIT-CP2 LSIT-CP2 LIT LSIT LIGT1 LSIGT1 LIT-CP2 LSIT-CP2 SKHB36BA0800 SKHB36BB0800 SKHB36BC0800 SKHB36BD0800 SKHB36BE0800 SKHB36BF0800 SKHB36BA1200 SKHB36BB1200 SKHB36BC1200 SKHB36BD1200 SKHB36BE1200 SKHB36BF1200 Terminal Lugs for Front connection (Cu/Al) IC @480 Vac, UL 489 List Price 65kA Product Number List Price $4588.00 $5953.00 $5798.00 $7163.00 $4888.00 $6253.00 $8077.00 $9442.00 $9287.00 $10652.00 $8377.00 $9742.00 SKLB36BA0800 SKLB36BB0800 SKLB36BC0800 SKLB36BD0800 SKLB36BE0800 SKLB36BF0800 SKLB36BA1200 SKLB36BB1200 SKLB36BC1200 SKLB36BD1200 SKLB36BE1200 SKLB36BF1200 $5552.00 $6917.00 $6762.00 $8127.00 $5852.00 $7217.00 $9048.00 $10413.00 $10258.00 $11623.00 $9348.00 $10713.00 IC @480 Vac, UL 489 100kA Product Number SKPB36BA0800 SKPB36BB0800 SKPB36BC0800 SKPB36BD0800 SKPB36BE0800 SKPB36BF0800 SKPB36BA1200 SKPB36BB1200 SKPB36BC1200 SKPB36BD1200 SKPB36BE1200 SKPB36BF1200 List Price $8734.00 $10099.00 $9944.00 $11309.00 $9034.00 $10399.00 $11854.00 $13219.00 $13064.00 $14429.00 $12154.00 $13519.00 Product Number List Price Wire Range TCAL81 $47.00 (3) 3/0-500 Cu (3) 3/0-500 Al TCAL125 $76.00 (4) 250-350 Cu3 (4) 250-500 Al MicroVersaTrip Plus, 100% UL Rated 4 GO-135S SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 3-Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only) Frame IC @480 Vac, UL 489 Current Sensor MOLDED CASE CIRCUIT BREAKERS 800 3 1200 12004 Trip Function 50kA Product Number LIT LSIT LIGT1 LSIGT1 LIT-CP2 LSIT-CP2 LIT LSIT LIGT1 LSIGT1 LIT-CP2 LSIT-CP2 LIT LSIT LIGT1 LSIGT1 LIT-CP2 LSIT-CP2 SKHH36BA0800 SKHH36BB0800 SKHH36BC0800 SKHH36BD0800 SKHH36BE0800 SKHH36BF0800 SKHH36BA1000 SKHH36BB1000 SKHH36BC1000 SKHH36BD1000 SKHH36BE1000 SKHH36BF1000 SKHH36BA1200 SKHH36BB1200 SKHH36BC1200 SKHH36BD1200 SKHH36BE1200 SKHH36BF1200 Terminal Lugs for Front connection (Cu/Al) IC @480 Vac, UL 489 List Price 65kA Product Number List Price $7975.00 $9340.00 $9185.00 $10550.00 $8275.00 $9640.00 $11624.00 $12989.00 $12834.00 $14199.00 $11924.00 $13289.00 $11624.00 $12989.00 $12834.00 $14199.00 $11924.00 $13289.00 SKLL36BA0800 SKLL36BB0800 SKLL36BC0800 SKLL36BD0800 SKLL36BE0800 SKLL36BF0800 SKLL36BA1000 SKLL36BB1000 SKLL36BC1000 SKLL36BD1000 SKLL36BE1000 SKLL36BF1000 SKLL36BA1200 SKLL36BB1200 SKLL36BC1200 SKLL36BD1200 SKLL36BE1200 SKLL36BF1200 $9892.00 $11257.00 $11102.00 $12467.00 $10192.00 $11557.00 $14414.00 $15779.00 $15624.00 $16989.00 $14714.00 $16079.00 $14414.00 $15779.00 $15624.00 $16989.00 $14714.00 $16079.00 MicroVersaTrip Plus and PM Rating Plug Selection -- All Plugs List Price, $106.00 800 SKHB, SKHH, SKLB, SKLL, SKPB, SKPP 1200 300 400 500 600 700 800 600 700 800 1000 1200 IC @480 Vac, UL 489 100kA Product Number SKPP36BA0800 SKPP36BB0800 SKPP36BC0800 SKPP36BD0800 SKPP36BE0800 SKPP36BF0800 SKPP36BA1000 SKPP36BB1000 SKPP36BC1000 SKPP36BD1000 SKPP36BE1000 SKPP36BF1000 SKPP36BA1200 SKPP36BB1200 SKPP36BC1200 SKPP36BD1200 SKPP36BE1200 SKPP36BF1200 List Price $11354.00 $12719.00 $12564.00 $13929.00 $11654.00 $13019.00 $15410.00 $16775.00 $16620.00 $17985.00 $15710.00 $17075.00 $15410.00 $16775.00 $16620.00 $17985.00 $15710.00 $17075.00 Product Number List Price Wire Range TCAL81 $47.00 (3) 3/0-500 Cu (3) 3/0-500 Al TCAL125 $76.00 (4) 250-350 Cu3 (4) 250-500 Al GO-135S SRPK800B300 SRPK800B400 SRPK800B500 SRPK800B600 SRPK800B700 SRPK800B800 SRPK1200B600 SRPK1200B700 SRPK1200B800 SRPK1200B1000 SRPK1200B12006 1For grounded neutral systems (1**/3w or 3**4w) a neutral current sensor is required. Refer to page 3-109. 2For +24 Vdc Control Power Accessories refer to pages 3-106 to 3-109. 3Suitable for 500 kcmil copper, 1200A max. rating. 4100% UL rated SK1200 supplied with back-connected assembly which increases breaker depth. Refer to outline drawing 168D1678 Sh2 for details. 5For ground fault neutral current sensor, use 1200A rating. 6Not suitable for use with 100% rated, 1000A breaker frame. 3-66 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers 300-1200A Circuit Breakers Electronic Trip Spectra RMS SK1200 with MicroVersaTrip PM 1 MicroVersaTrip PM, Standard UL Rated (No Protective Relays) SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 3-Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only) Frame IC @480 Vac, UL 489 Current Sensor 800 1200 Trip Function 50kA Product Number LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 SKHB36CA0800 SKHB36CB0800 SKHB36CC0800 SKHB36CD0800 SKHB36CA1200 SKHB36CB1200 SKHB36CC1200 SKHB36CD1200 Terminal Lugs for Front connection (Cu/Al) IC @480 Vac, UL 489 List Price 65kA Product Number List Price $5788.00 $7153.00 $6998.00 $8363.00 $9277.00 $10642.00 $10487.00 $11852.00 SKLB36CA0800 SKLB36CB0800 SKLB36CC0800 SKLB36CD0800 SKLB36CA1200 SKLB36CB1200 SKLB36CC1200 SKLB36CD1200 $6752.00 $8117.00 $7962.00 $9327.00 $10248.00 $11613.00 $11458.00 $12823.00 IC @480 Vac, UL 489 100kA Product Number SKPB36CA0800 SKPB36CB0800 SKPB36CC0800 SKPB36CD0800 SKPB36CA1200 SKPB36CB1200 SKPB36CC1200 SKPB36CD1200 List Price $9934.00 $11299.00 $11144.00 $12509.00 $13054.00 $14419.00 $14264.00 $15629.00 Product Number List Price Wire Range TCAL81 $47.00 (3) 3/0-500 Cu (3) 3/0-500 Al TCAL125 $76.00 (4) 250-350 Cu3 (4) 250-500 Al MicroVersaTrip PM, 100% UL Rated (No Protective Relays) SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 3-Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only) Frame Current Sensor 800 12004 12005 Trip Function 50kA Product Number LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 SKHH36CA0800 SKHH36CB0800 SKHH36CC0800 SKHH36CD0800 SKHH36CA1000 SKHH36CB1000 SKHH36CC1000 SKHH36CD1000 SKHH36CA1200 SKHH36CB1200 SKHH36CC1200 SKHH36CD1200 Terminal Lugs for Front connection (Cu/Al) IC @480 Vac, UL 489 List Price 5kA Product Number List Price $9175.00 $10540.00 $10385.00 $11750.00 $12824.00 $14189.00 $14034.00 $15399.00 $12824.00 $14189.00 $14034.00 $15399.00 SKLL36CA0800 SKLL36CB0800 SKLL36CC0800 SKLL36CD0800 SKLL36CA1000 SKLL36CB1000 SKLL36CC1000 SKLL36CD1000 SKLL36CA1200 SKLL36CB1200 SKLL36CC1200 SKLL36CD1200 $11092.00 $12457.00 $12302.00 $13667.00 $15614.00 $16979.00 $16824.00 $18189.00 $15614.00 $16979.00 $16824.00 $18189.00 MicroVersaTrip Plus and PM Rating Plug Selection -- All Plugs List Price, $106.00 300 400 500 600 700 800 600 700 800 1000 1200 800 SKHB, SKHH, SKLB, SKLL, SKPB, SKPP 1200 IC @480 Vac, UL 489 00kA Product Number SKPP36CA0800 SKPP36CB0800 SKPP36CC0800 SKPP36CD0800 SKPP36CA1000 SKPP36CB1000 SKPP36CC1000 SKPP36CD1000 SKPP36CA1200 SKPP36CB1200 SKPP36CC1200 SKPP36CD1200 List Price $12554.00 $13919.00 $13764.00 $15129.00 $16610.00 $17975.00 $17820.00 $19185.00 $16610.00 $17975.00 $17820.00 $19185.00 Product Number List Price Wire Range TCAL81 $47.00 (3) 3/0-500 Cu (3) 3/0-500 Al TCAL125 $76.00 (4) 250-350Cu4 (4) 250-500 Al 3 GO-135S SRPK800B300 SRPK800B400 SRPK800B500 SRPK800B600 SRPK800B700 SRPK800B800 SRPK1200B600 SRPK1200B700 SRPK1200B800 SRPK1200B1000 SRPK1200B12006 1MicroVersaTrip PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages 3-106 to 3-109. 2For grounded neutral systems (1**/3w or 3**4w) a neutral current sensor is required. Refer to page 3-109. 3Suitable for 500 kcmil copper, 1200A max. rating. 4For ground fault neutral current sensor, use 1200A rating. 5100% UL rated SK1200 supplied with back-connected assembly which increases breaker depth. Refer to outline drawing 168D1678 Sh2 for details. 6Not suitable for use with 100% rated, 1000A breaker frame. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com MOLDED CASE CIRCUIT BREAKERS IC @480 Vac, UL 489 BuyLog Catalog 3-67 Prices and data subject to change without notice Molded Case Circuit Breakers Industrial Circuit Breakers 300-1200A Circuit Breakers Electronic Trip Spectra RMS SK1200 with MicroVersaTrip Plus and PM 1 MicroVersaTrip PM, Standard UL Rated (With Protective Relaying) SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 3-Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only) Frame IC @480 Vac, UL 489 Current Sensor 800 1200 Terminal Lugs for Front connection (Cu/Al) IC @480 Vac, UL 489 IC @480 Vac, UL 489 Trip Function 50kA Product Number List Price, GO-135PM 65kA Product Number List Price, GO-135PM 100kA Product Number List Price, GO-135PM LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 SKHB36DA0800 SKHB36DB0800 SKHB36DC0800 SKHB36DD0800 SKHB36DA1200 SKHB36DB1200 SKHB36DC1200 SKHB36DD1200 $6988.00 $8353.00 $8198.00 $9563.00 $10477.00 $11842.00 $11687.00 $13052.00 SKLB36DA0800 SKLB36DB0800 SKLB36DC0800 SKLB36DD0800 SKLB36DA1200 SKLB36DB1200 SKLB36DC1200 SKLB36DD1200 $7952.00 $9317.00 $9162.00 $10527.00 $11448.00 $12813.00 $12658.00 $14023.00 SKPB36DA0800 SKPB36DB0800 SKPB36DC0800 SKPB36DD0800 SKPB36DA1200 SKPB36DB1200 SKPB36DC1200 SKPB36DD1200 $11134.00 $12499.00 $12344.00 $13709.00 $14254.00 $15619.00 $15464.00 $16829.00 List Price, GO-135S Wire Range TCAL81 $47.00 (3) 3/0-500 Cu (3) 3/0-500 Al TCAL125 $76.00 (4) 250-350 Cu3 (4) 250-500 Al Product Number MicroVersaTrip PM, 100% UL Rated (With Protective Relays) SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350 3-Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only) Frame IC @480 Vac, UL 489 Current Sensor MOLDED CASE CIRCUIT BREAKERS 800 3 12004 12005 Terminal Lugs for Front connection (Cu/Al) IC @480 Vac, UL 489 IC @480 Vac, UL 489 Trip Function 50kA Product Number List Price, GO-135PM 65kA Product Number List Price, GO-135PM 100kA Product Number List Price, GO-135PM LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 LIT LSIT LIGT2 LSIGT2 SKHH36DA0800 SKHH36DB0800 SKHH36DC0800 SKHH36DD0800 SKHH36DA1000 SKHH36DB1000 SKHH36DC1000 SKHH36DD1000 SKHH36DA1200 SKHH36DB1200 SKHH36DC1200 SKHH36DD1200 $10375.00 $11740.00 $11585.00 $12950.00 $14024.00 $15389.00 $15234.00 $16599.00 $14024.00 $15389.00 $15234.00 $16599.00 SKLL36DA0800 SKLL36DB0800 SKLL36DC0800 SKLL36DD0800 SKLL36DA1000 SKLL36DB1000 SKLL36DC1000 SKLL36DD1000 SKLL36DA1200 SKLL36DB1200 SKLL36DC1200 SKLL36DD1200 $12292.00 $13657.00 $13502.00 $14867.00 $16814.00 $18179.00 $18024.00 $19389.00 $16814.00 $18179.00 $18024.00 $19389.00 SKPP36DA0800 SKPP36DB0800 SKPP36DC0800 SKPP36DD0800 SKPP36DA1000 SKPP36DB1000 SKPP36DC1000 SKPP36DD1000 SKPP36DA1200 SKPP36DB1200 SKPP36DC1200 SKPP36DD1200 $13754.00 $15119.00 $14964.00 $16329.00 $17810.00 $19175.00 $19020.00 $20385.00 $17810.00 $19175.00 $19020.00 $20385.00 MicroVersaTrip Plus and PM Rating Plug Selection -- All Plugs List Price, $106.00 800 SKHB, SKHH, SKLB, SKLL, SKPB, SKPP 1200 300 400 500 600 700 800 600 700 800 1000 1200 List Price, GO-135S Wire Range TCAL81 $47.00 (3) 3/0-500 Cu (3) 3/0-500 Al TCAL125 $76.00 Product Number (4) 250-350 Cu3 (4) 250-500 Al GO-135S SRPK800B300 SRPK800B400 SRPK800B500 SRPK800B600 SRPK800B700 SRPK800B800 SRPK1200B600 SRPK1200B700 SRPK1200B800 SRPK1200B1000 SRPK1200B12006 1MicroVersaTrip PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages 3-106 to 3-109. 2For grounded neutral systems (1**/3w or 3**4w) a neutral current sensor is required. Refer to page 3-109. 3Suitable for 500 kcmil copper, 1200A max. rating. 4For ground fault neutral current sensor, use 1200A rating. 5100% UL rated SK1200 supplied with back-connected assembly which increases breaker depth. Refer to outline drawing 168D1678 Sh2 for details. 6Not suitable for use with 100% rated, 1000A breaker frame. 3-68 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers 300-1200A Circuit Breakers Thermal-Magnetic Trip K1200 Line Circuit Breakers Types TKM, THMK Types TKM, THKM -- Interchangeable Trip, not suitable for reverse feed GO-135B Complete Circuit Breaker Includes Line and Load Lugs Terminal Lugs for Front Connection (Cu/Al)1 Adjustable Instantaneous AmpereTrip Ampere Range Standard Rating Low High Product Number List Price Hi-Break1 Product Number List Price 800A 300 350 400 450 500 600 700 800 Frame--Two-Pole 900 3000 TKMA826300WL 1050 3500 TKMA826350WL 1200 4000 TKMA826400WL 1350 4500 TKMA826450WL 1500 5000 TKMA826500WL 1800 6000 TKMA826600WL 2100 6400 TKMA826700WL 2400 6400 TKMA826800WL $3672.00 $3672.00 $3672.00 $3672.00 $3672.00 $3672.00 $3700.00 $3700.00 THKMA826300WL THKMA826350WL THKMA826400WL THKMA826450WL THKMA826500WL THKMA826600WL THKMA826700WL THKMA826800WL $4579.00 $4579.00 $4579.00 $4579.00 $4579.00 $4579.00 $4611.00 $4611.00 800A 300 350 400 450 500 600 700 800 800 Mag Only Frame--Three-Pole 900 3000 TKMA836300WL 1050 3500 TKMA836350WL 1200 4000 TKMA836400WL 1350 4500 TKMA836450WL 1500 5000 TKMA836500WL 1800 6000 TKMA836600WL 2100 6400 TKMA836700WL 2400 6400 TKMA836800WL 1200 4000 -- 2400 8000 -- $4713.00 $4713.00 $4713.00 $4713.00 $4713.00 $4713.00 $4755.00 $4755.00 -- -- THKMA836300WL THKMA836350WL THKMA836400WL THKMA836450WL THKMA836500WL THKMA836600WL THKMA836700WL THKMA836800WL -- -- $5624.00 $5624.00 $5624.00 $5624.00 $5624.00 $5624.00 $5666.00 $5666.00 -- -- Frame Only Product Number List Price TKM826F000 Standard Frame $1244.00 THKM826F000 Hi-Break Frame TKM836F000 Standard Frame THKM836F000 Hi-Break Frame $2167.00 $2205.00 $3116.00 Trip Unit Only. Use with Standard and Hi-Break Frames List Price TKMA836T300 TKMA836T350 TKMA836T400 TKMA836T450 TKMA836T500 TKMA836T600 TKMA836T700 TKMA836T800 $2268.00 $2268.00 $2268.00 $2268.00 $2268.00 $2268.00 $2268.00 $2268.00 TKMA836T300 TKMA836T350 TKMA836T400 TKMA836T450 TKMA836T500 TKMA836T600 TKMA836T700 TKMA836T800 $2268.00 $2268.00 $2268.00 $2268.00 $2268.00 $2268.00 $2268.00 $2268.00 TKMA836TM483 $2268.00 $2268.00 TKMA836TM683 Product Number (Order 2 List per pole) Price Wire Size TCAL61 $40.00 (2) 2/0-500 Cu/Al TCAL81 $47.002 (3) 3/0-500 Cu/Al TCAL61 $40.00 (2) 2/0-500 Cu/Al TCAL81 $47.004 (3) 3/0-500 Cu/Al 1For optional lugs, see page 3-101. 2Not UL listed. 3Internal accessory installation requires dummy trip unit. See page 3-91 for additional details. Nonautomatic trip unit and dummy trip unit not UL listed for field installation. MOLDED CASE CIRCUIT BREAKERS 4GO-135S. 3 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-69 Prices and data subject to change without notice Molded Case Circuit Breakers Industrial Circuit Breakers 300-1200A Circuit Breakers Thermal-Magnetic Trip K1200 Line Circuit Breakers Types TKM, THMK Types TKM, THKM -- Interchangeable Trip, not suitable for reverse feed GO-135B Complete Circuit Breaker Includes Line and Load Lugs Terminal Lugs for Front Connection (Cu/Al)1 Adjustable Instantaneous AmpereTrip Ampere Range Standard Rating Low High Product Number 1200 600 700 800 1000 1200 Frame--Two-Pole 1800 6000 TKMA20600WL 2100 6400 TKMA20700WL 2400 6400 TKMA20800WL 3000 10000 TKMA21000WL3 3600 10000 TKMA21200WL3 List Price Hi-Break1 Product Number List Price Frame Only Product Number List Price $5172.00 $5172.00 $5172.00 $5472.00 $7471.00 THKMA20600WL THKMA20700WL THKMA20800WL THKMA21000WL3 THKMA21200WL3 $6069.00 $6069.00 $6069.00 $6353.00 $8368.00 TKM2F Standard Frame $2690.00 THKM2F Hi-Break Frame 1200 600 700 800 1000 1200 1200 Mag Only Frame--Three-Pole 1800 6000 TKMA30600WL 2100 6400 TKMA30700WL 2400 6400 TKMA30800WL 3000 10000 TKMA31000WL4 3600 10000 TKMA31200WL4 1800 2400 6000 8000 -- -- Trip Unit Only. Use with Standard and Hi-Break Frames List Price TKMA3T0600 TKMA3T0700 TKMA3T0800 TKMA3T10004 TKMA3T12004 $2294.00 $2294.00 $2294.00 $2478.00 $4477.00 TKMA3T0600 TKMA3T0700 TKMA3T0800 TKMA3T10004 TKMA3T12004 TKMA3TM5123 TKMA3TM6123 Product Number (Order 2 List per pole) Price TCAL81 $47.002 TCAL121 $76.002 $2294.00 $2294.00 $2294.00 $2478.00 $4477.00 TCAL81 $47.002 $4477.00 $4477.00 TCAL121 $76.002 $3587.00 $5885.00 $5885.00 $5885.00 $6243.00 $8242.00 THKMA30600WL THKMA30700WL THKMA30800WL THKMA31000WL4 THKMA31200WL4 $6795.00 $6795.00 $6795.00 $7153.00 $9152.00 TKM3F Standard Frame $3309.00 -- -- -- -- -- -- THKM2F Hi-Break Frame $4219.00 Wire Size (3) 3/0-500 Cu/Al (4) 250-3505 Cu or (4) 300-500 Al (3) 3/0-500 Cu/Al (4) 250-3505 Cu or (4) 300-500 Al 1For optional lugs, see page 3-101. 2GO-135S. 3Not UL listed. 4Not Suitable for use on dc systems. 5Suitable for 500 kcmil Cu for voltage drop considerations. MOLDED CASE CIRCUIT BREAKERS Accessories: See pages 3-85 to 3-104. 3 3-70 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Industrial Circuit Breakers 400-2000A Circuit Breakers Electronic Trip R Frame Circuit Breaker Frames --R-Frame Molded Case Circuit Breaker Frames --600 Vac, 50/60 Hz, 3-Poles only. Suitable for Reverse Feed --Complete breaker requires frame and rating plug. --For 4-wire GF application, select neutral CT from page 3-105, order separately. --IC Ratings shown are at 480 Vac. Circuit Breaker Frame Selection MicroVersaTrip Plus Trip Units R-Frame Current Sensors and Rating Plugs GO-135S 1000 A 1600 A 2000 A Trip Function LIT LSIT LIGT LSIGT LIGTZ1 LSIGTZ1 LSIGTZ2 LIT LSIT LIGT LSIGT LIGTZ1 LSIGTZ1 LSIGTZ2 LIT LSIT LIGT LSIGT LIGTZ1 LSIGTZ1 LSIGTZ2 65kAIC Product Number List Price TRLA36BA10 $10610.00 TRLA36BB10 $11975.00 TRLA36BC10 $11820.00 TRLA36BD10 $13185.00 TRLA36BE10 $12405.00 TRLA36BF10 $13770.00 TRLA36BG10 $14355.00 TRLA36BA16 $10610.00 TRLA36BB16 $11975.00 TRLA36BC16 $11820.00 TRLA36BD16 $13185.00 TRLA36BE16 $12405.00 TRLA36BF16 $13770.00 TRLA36BG16 $14355.00 TRLA36BA20 $11488.00 TRLA36BB20 $12853.00 TRLA36BC20 $12698.00 TRLA36BD20 $14063.00 TRLA36BE20 $13283.00 TRLA36BF20 $14648.00 TRLA36BG20 $15233.00 100% Rating 65kAIC Product Number List Price TRLL36BA10 $13871.00 TRLL36BB10 $15236.00 TRLL36BC10 $15081.00 TRLL36BD10 $16446.00 TRLL36BE10 $15666.00 TRLL36BF10 $17031.00 TRLL36BG10 $17616.00 TRLL36BA16 $13871.00 TRLL36BB16 $15236.00 TRLL36BC16 $15081.00 TRLL36BD16 $16446.00 TRLL36BE16 $15666.00 TRLL36BF16 $17031.00 TRLL36BG16 $17616.00 TRLL36BA20 $14986.00 TRLL36BB20 $16351.00 TRLL36BC20 $16196.00 TRLL36BD20 $17561.00 TRLL36BE20 $16781.00 TRLL36BF20 $18146.00 TRLL36BG20 $18731.00 Standard Rating Current Sensor 1000 A 1600 A 2000 A Trip Function LIT LSIT LIGT LSIGT LIGTZ1 LSIGTZ1 LSIGTZ2 LIT LSIT LIGT LSIGT LIGTZ1 LSIGTZ1 LSIGTZ2 LIT LSIT LIGT LSIGT LIGTZ1 LSIGTZ1 LSIGTZ2 100kAIC Product Number List Price TRPA36BA10 $12465.00 TRPA36BB10 $13830.00 TRPA36BC10 $13675.00 TRPA36BD10 $15040.00 TRPA36BE10 $14260.00 TRPA36BF10 $15625.00 TRPA36BG10 $16210.00 TRPA36BA16 $12465.00 TRPA36BB16 $13830.00 TRPA36BC16 $13675.00 TRPA36BD16 $15040.00 TRPA36BE16 $14260.00 TRPA36BF16 $15625.00 TRPA36BG16 $16210.00 TRPA36BA20 $13472.00 TRPA36BB20 $14837.00 TRPA36BC20 $14682.00 TRPA36BD20 $16047.00 TRPA36BE20 $15267.00 TRPA36BF20 $16632.00 TRPA36BG20 $17217.00 Sensor Current Rating 1000 A 1600 A 2000 A Rating Plug Removal Tool 400 A 600 A 800 A 1000A 600 A 800 A 1000 A 1100 A 1200 A 1600 A 750 A 800 A 1000 A 1200 A 1500 A 1600 A 2000 A List Price TR10B400 TR10B600 TR10B800 TR10B1000 TR16B600 TR16B800 TR16B1000 TR16B1100 TR16B1200 TR16B1600 TR20B750 TR20B800 TR20B1000 TR20B1200 TR20B1500 TR20B1600 TR20B2000 TRTOOL $89.00 $89.00 $89.00 $89.00 $89.00 $89.00 $89.00 $89.00 $89.00 $89.00 $89.00 $89.00 $89.00 $89.00 $89.00 $89.00 $89.00 $12.001 1GO-135S. MOLDED CASE CIRCUIT BREAKERS Standard Rating Current Sensor GO-245A Rating Plug Product Number 100% Rating 100kAIC Product Number List Price TRPP36BA10 $16258.00 TRPP36BB10 $17623.00 TRPP36BC10 $17468.00 TRPP36BD10 $18833.00 TRPP36BE10 $18053.00 TRPP36BF10 $19418.00 TRPP36BG10 $20003.00 TRPP36BA16 $16258.00 TRPP36BB16 $17623.00 TRPP36BC16 $17468.00 TRPP36BD16 $18833.00 TRPP36BE16 $18053.00 TRPP36BF16 $19418.00 TRPP36BG16 $20003.00 TRPP36BA20 $17566.00 TRPP36BB20 $18931.00 TRPP36BC20 $18776.00 TRPP36BD20 $20141.00 TRPP36BE20 $19361.00 TRPP36BF20 $20726.00 TRPP36BG20 $21311.00 3 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-71 Prices and data subject to change without notice Molded Case Circuit Breakers Molded Case Switches 150-1200A Spectra RMS Molded Case Switches GO-135S UL File E-57546, CSA LR 91464 Includes fixed, high-set Instantaneous trip suitable for reverse feed. Frame Type Ampere Rating Product Number List Price SE150 100 150 250 SEDA36AN0100 SEDA36AN0150 SFDA36AN0250 $650.00 $948.00 $1126.00 TCAL18 $3.00 TCAL29 $8.00 400 SGDA36AN0400 $1813.00 3-pole lug kit 600 SGDA36AN0600 $2489.00 TCLK3653 $42.00 800 SKDA36AN0800 $2483.00 TCAL81 $47.00 1000 SKDA36AN1000 $3600.00 1200 SKDA36AN1200 $3600.00 SF250 SG600 SK1200 Maximum Sort Circuit Withstand Rating2 (kA rms symmetrical) Terminal Lugs for Front Connection (Cu/Al) Switch1 Product Number TCAL125 List Price $76.00 Wire Range 240 Vac Aluminum: #12-3/0 Copper: #14-3/0 Aluminum: #8-350 kcmil Copper: #8-350 kcmil Aluminum: (2) 2/0-500 kcmil or (1) #6-600 kcmil Copper: (2) 2/0-500 kcmil or (1) #8-600 kcmil Aluminum: (3) 3/0-500 kcmil Copper: (3) 3/0-500 kcmil Aluminum: (4) 250-500 kcmil Copper: (4) 250-350 kcmil4 200 480 Vac 100 600 Vac 25 200 100 25 200 100 42 100 65 42 1No rating plug required. 2The maximum withstand rating is limited by the application to the value set forth in this table or the short circuit rating of the upstream fuse or circuit breaker, whichever is less. The upstream protective device must have an instantaneous trip function or element and its rated ampacity may not exceed the ampere rating of the switch. 3Order one kit for either line or load end; two kits required for both. 4Suitable for 500 kcmil copper, 1200A max. rating. MOLDED CASE CIRCUIT BREAKERS Noninterchangeable Trip, Includes Cu/Al load lugs. For optional lugs, see page 3-101 and 3-102. GO-135B Type Ampere Rating Number of Poles Voltage Rating Product Number List Price TEB TEB TEB TED TED TED TFJ TFJ TJJ TJJ 100 100 100 100 100 150 225 225 400 400 1 2 3 1 2 2 2 3 2 2 120 Vac, 125 Vdc 240 Vac, 250 Vdc 240 Vac 277 Vac, 125 Vdc 480 Vac, 250 Vdc 480 Vac, 250 Vdc 480 Vac 600 Vac 600 Vac, 250 Vdc 600 Vac TEB111Y1005 TEB122Y1005 TEB132Y1005 TED113Y1005 TED124Y1005 TED124Y1505,6 TFJ226Y2255,7 TFJ236Y225 TJJ426Y4008 TJJ436Y4008 $65.50 $159.00 $240.00 $82.50 $263.00 $708.00 $803.00 $1174.00 $1577.00 $1904.00 3 Interchangeable Trip, Includes Cu/Al load lugs. For optional lugs, see page 3-101 and 3-102. Type Ampere Rating Number of Poles Voltage Rating TFK TFK TJK TJK TJK TJK TMK TMK TMK TMK TMK TMK 225 225 400 400 600 600 800 800 1000 1000 1200 1200 2 3 2 3 2 3 2 3 2 3 2 3 480 Vac, 250 Vdc 600 Vac, 250 Vdc 600 Vac, 250 Vdc 600 Vac, 250 Vdc 600 Vac, 250 Vdc 600 Vac, 250 Vdc 600 Vac, 250 Vdc 600 Vac, 250 Vdc 600 Vac, 250 Vdc 600 Vac, 250 Vdc 600 Vac, 250 Vdc 600 Vac, 250 Vdc GO-135B Product Number List Price TFK226Y2257,8,9 TFK236Y2258,9 TJK426Y4008 TJK436Y4008 TJK626Y6008 TJK636Y6008 TMKA836Y8008 TMKA826Y8008 TMKA2Y10008 TMKA3Y10008 TMKA2Y12008 TMKA3Y12008 $937.00 $1174.00 $1874.00 $2330.00 $1844.00 $2595.00 $1692.00 $2769.00 $3311.00 $4030.00 $3420.00 $4191.00 5Internal accessory requires factory installed dummy trip. Specify on order. Accessories not available for one-pole TEB, TED. 6Not UL listed. 7600 Volts max. 8Internal accessory requires factory installed dummy trip unit. See page 3-91 for additional details. Nonautomatic trip unit and dummy trip not UL listed for field installation. 9UL listed only when ordered as a complete switch. 3-72 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Motor Circuit Protectors 3-1200A Spectra RMS Spectra RMS Mag-Break Motor Circuit Protectors Current Limiting, UL Component Recognized 1 Features --Suitable for Reverse Feed --UL Recognized File E-11592 --CSA Certified LR 40350 --IEC 947-2 690 Vac Max. --SE 150 160 Ampere Max. --SF250 250 Ampere Max. --SG600 630 Ampere Max. --SK1200 1250 Ampere Max. --UL Current Limiting High Interrupting Capacity Spectra RMS Motor Circuit Protectors Rating Plug Adjustable Instantaneous Trip Ampere Range Low Product Number High SE150 Line 3-Pole 3 11 7 22 15 43 20 58 25 73 30 87 40 118 50 148 60 178 70 206 80 236 90 267 100 297 110 328 125 374 150 450 Terminal Lugs for Front Connection (Cu/Al) 39 90 182 254 332 415 501 637 777 863 999 1138 1280 1426 1640 1991 List Price, GO-135S SRPE7A3 SRPE7A7 SRPE30A15 SRPE30A20 SRPE30A25 SRPE30A30 SRPE60A40 SRPE60A50 SRPE60A60 SRPE100A70 SRPE100A80 SRPE100A90 SRPE100A100 SRPE150A110 SRPE150A125 SRPE150A150 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor Product Number List Price, GO-141S 100kAIC @480 Vac Product Number List Price, GO-141S Product Number List Price, GO-135S 7 SELA36AI0007 $530.00 SEPA36AI0007 $663.00 TCAL18 $3.00 30 SELA36AI0030 $530.00 SEPA36AI0030 $663.00 TCAL18 $3.00 Wire Range 14-3/0 Cu 60 SELA36AI0060 $686.00 SEPA36AI0060 $858.00 TCAL18 $3.00 12-3/0 Al 100 SELA36AI0100 $754.00 SEPA36AI0100 $943.00 TCAL18 $3.00 150 SELA36AI0150 $848.00 SEPA36AI0150 $1060.00 TCAL18 $3.00 Standard Capacity Mag-Break Motor Circuit Protectors--Adjustable Magnetic Trip, Noninterchangeable Types TEC, TECL GO-141 Complete Breaker (includes line and load lugs) Adjustable Trip Ampere Range2 Two-Pole, 480 Vac3 Three-Pole, 600 Vac Add-on Limiter Three-Pole, 100 kAIC Ampere Rating Low High Product Number List Price Product Number List Price Product Number List Price 3 7 15 30 50 100 150 8 18 42 90 180 300 600 38 90 198 390 660 1300 2700 TEC24003 TEC24007 TEC24015 TEC24030 TEC24050 TEC24100 TEC24150 $318.00 $318.00 $318.00 $318.00 $377.00 $413.00 $477.00 TEC36003 TEC36007 TEC36015 TEC36030 TEC36050 TEC36100 TEC36150 $388.00 $388.00 $388.00 $388.00 $464.00 $498.00 $545.00 TECL36003 TECL36007 TECL36015 TECL36030 TECL36050 TECL36100 TECL36150 $231.00 $231.00 $231.00 $231.00 $231.00 $524.00 $1079.00 1Per UL 489, interrupting capacities are not shown on product label. 2AC only 3Two-pole furnished in three-pole case. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-73 Prices and data subject to change without notice MOLDED CASE CIRCUIT BREAKERS Ampere Rating Frame 65kAIC @480 Vac 3 Molded Case Circuit Breakers Motor Circuit Protectors 150-1200A Spectra RMS Spectra RMS Mag-Break Motor Circuit Protectors Current Limiting, UL Component Recognized 1 SF250 Line 3-Pole Rating Plug Ampere Rating Low SE150 Line 3-Pole 70 205 90 265 100 295 110 325 125 370 150 440 175 515 200 590 225 665 250 736 Product Number High 700 900 1000 1100 1250 1500 1750 2000 2250 2500 Frame Terminal Lugs for Front Connection (Cu/Al) 65kAIC @480 Vac Adjustable Instantaneous Trip Ampere Range List Price, GO-135S SRPF250A70 SRPF250A90 SRPF250A100 SRPF250A110 SRPF250A125 SRPF250A150 SRPF250A175 SRPF250A200 SRPF250A225 SRPF250A250 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Current Sensor 250 Product Number SFLA36AI0250 List Price, GO-141S $1297.00 100kAIC @480 Vac Product Number SFPA36AI0250 List Price, GO-141S $1622.00 Product Number TCAL29 Types TFC, TJC, TKC 3-Pole $8.00 8-350 Cu 8-350 Al Complete Breaker (includes line and load lugs) Ampere Rating Low High Product Number List Price 225 600 100 330 550 1000 1200 1000 1800 3000 5000 3000 5000 1400 2250 1100 1670 3300 4000 3300 6000 6000 10000 6000 10000 TFC36225 TFC36225A TJC36400E TJC36400F TJC36400G TJC36400B TJC36600G TJC36600H TKC36800L2 TKC36800M2 TKC361200L2 TKC361200M2 $1448.00 $1448.00 $2589.00 $2589.00 $2589.00 $2589.00 $3676.00 $3676.00 $4880.00 $4880.00 $8412.00 $8412.00 400 600 800 MOLDED CASE CIRCUIT BREAKERS Wire Range GO-135B Adjustable Instantaneous Trip Ampere Range 3 List Price, GO-135S 1200 1200 Type TBC with Current Limiters GO-135B Complete Breaker (includes line and load lugs) Adjustable Instantaneous Trip Ampere Range Standard Replacement Current Limiters Three-Pole Ampere Rating Low High Product Number List Price Product Number List Price 225 400 600 800 550 1000 3000 2400 1670 3300 6000 6000 TBC43225F14F TBC43400F14G TBC63600J14L TBC83800K222 $3810.00 $5149.00 $7443.00 $8622.00 TB10F14 TB10F14 TB10BJ14 TB15K22 $377.00 $377.00 $543.00 $543.00 1Per UL 489, interrupting capacities are not shown on product label. 2Balanced three-phase inrush current will trip the circuit breaker at lower than indicated currents. For motors over 350 hp, use Spectra RMS SK frame or circuit breakers with MicroVersaTrip Plus Trip Units Accessories: See pages 3-83 to 3-104. 3-74 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Motor Circuit Protectors 150-1200A Spectra RMS Spectra RMS Mag-Break Motor Circuit Protectors Current Limiting, UL Component Recognized 1 SG 600 Line 3-Pole Rating Plug Ampere Rating Frame Low High Product Number List Price, GO-135S 400 Ampere Max. 125 380 150 455 175 530 200 605 225 680 250 755 300 905 350 1060 400 1210 1275 1530 1785 2040 2295 2550 3060 3570 4080 SRPG400A125 SRPG400A150 SRPG400A175 SRPG400A200 SRPG400A225 SRPG400A250 SRPG400A300 SRPG400A350 SRPG400A400 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 600 Ampere 250 300 350 400 450 500 600 2530 3035 3545 4050 4555 5060 6075 SRPG600A250 SRPG600A300 SRPG600A350 SRPG600A400 SRPG600A450 SRPG600A500 SRPG600A600 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 Max. 765 915 1070 1220 1375 1525 1830 Terminal Lugs for Front Connection (Cu/Al) 65kAIC @480 Vac Adjustable Instantaneous Trip Ampere Range Current Sensor Product Number List Price, GO-141S Product Number List Price, GO-141S Product Number List Price, GO-135S 3-Pole lug kit 400 SGLA36AI0400 $2396.00 SGPA36AI0400 $2995.00 TCLK3652 Wire Range (2) 2/0-500 Cu or (1) 8-600 Cu $42.00 (2) 2/0-500 Al or (1) 6-600 Al 3-Pole lug kit 600 SGLA36AI0600 $3481.00 SGPA36AI0600 $4350.00 TCLK3652 (2) 2/0-500 Cu or (1) 8-600 Cu $42.00 (2) 2/0-500 Al or (1) 6-600 Al SK1200 Line (Not Current Limiting) 3-Pole Rating Plug Frame Low High Product Number List Price, GO-135S Max. 940 1250 1570 1875 2155 2440 3015 4015 5020 6195 7420 8705 SRPK800A300 SRPK800A400 SRPK800A500 SRPK800A600 SRPK800A700 SRPK800A800 $106.00 $106.00 $106.00 $106.00 $106.00 $106.00 1200 Ampere Max. 600 1825 700 2125 800 2430 100 3040 1200 3650 6110 7125 8145 10180 12215 SRPK1200A600 SRPK1200A700 SRPK1200A800 SRPK1200A1000 SRPK1200A1200 $106.00 $106.00 $106.00 $106.00 $106.00 800 Ampere 300 400 500 600 700 800 Terminal Lugs for Front Connection (Cu/Al) 65kAIC @480 Vac Current Sensor Product Number List Price, GO-141S Product Number List Price, GO-135S $4490.00 TCAL81 $47.00 Wire Range (3) 3/0-500 Cu 800 SKLA36AI0800 (3) 3/0-500 Al (4) 250-500 Cu3 1200 SKLA36AI1200 $7859.00 TCAL125 $76.00 (4) 250-350 Al 1Per UL 489, interrupting capacities are not shown on product label. 2Order one kit for either the line or load end; two kits required for both. 3Suitable for 500 kcmil copper, 1200A max. rating. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog MOLDED CASE CIRCUIT BREAKERS Ampere Rating Adjustable Instantaneous Trip Ampere Range 3-75 Prices and data subject to change without notice 3 Molded Case Circuit Breakers Special Purpose Mine Duty Breakers Mine Duty Circuit Breakers Standard Duty 50-1200 amperes 600 Vac 300 Vdc Three-Pole 1000 Wye 577 Vac (Not UL Listed) -- Without Line or Load Lugs 1 GO-135A Complete Breaker Frame Only Thermal Magnetic Ampere Rating Magnetic Instantaneous Trip Low High Product Number Magnetic Only List Price Product Number Thermal Magnetic List Price Product Number Product Number List Price Magnetic Only List Price Product Number List Price E Frame -- 100 Amperes Maximum, Noninterchangeable Trip 50 502 1802 TE131050MD $1104.00 TE131M050MD $1104.00 100 1002 5002 TE131100MD $1104.00 TE131M100MD $1104.00 -- -- J Frame -- 225 Amperes Maximum, Interchangeable Trip3 225 300 1000 TJ132225MD1 225 500 1500 TJ132225MD2 -- -- TJ132M2MD1 TJ132M2MD2 -- -- TJ132FMD -- $3231.00 TJ32225TMD1 -- TJ32225TMD2 $920.00 $920.00 TJ32M2TMD1 TJ32M2TMD2 $920.00 $920.00 J Frame -- 400 Amperes Maximum, Interchangeable Trip3 400 500 1500 TJ134400MD2 400 900 3000 TJ134400MD3 -- -- TJ134M4MD2 TJ134M4MD3 -- -- TJ134FMD -- $4499.00 TJ34400TMD2 -- TJ34400TMD3 $1007.00 $1007.00 TJ34M4TMD2 TJ34M4TMD3 $1007.00 $1007.00 J Frame -- 600 Amperes Maximum, Interchangeable Trip3 600 900 3000 TJ136600MD3 -- TJ136M6MD3 -- TJ136FMD $4636.00 TJ36600TMD3 $1071.00 TJ36M6TMD3 $1671.00 -- -- -- -- -- -- -- -- -- -- TK13M8MD4 TK13M8MD5 -- -- -- -- -- -- -- -- TK138FMD -- -- -- -- -- $5296.00 -- -- -- $1815.00 $1815.00 $2813.00 $2813.00 $2813.00 $2813.00 -- -- -- -- TK38M8TMD4 TK38M8TMD5 -- -- -- -- $2813.00 $2813.00 -- -- -- TK13M12MD5 -- -- TK13AFMD -- $7600.00 TK3A10TMD5 -- TK3A12TMD5 $5923.00 $5923.00 -- TK3M12TMD5 -- $5923.00 K Frame -- 800 Amperes Maximum, 300 900 3000 400 1250 3000 600 1250 3000 600 2000 4000 800 1250 3000 800 2000 4000 -- -- -- -- -- -- -- -- -- -- Interchangeable Trip3 TK138600MD3 TK138400MD4 TK138600MD4 TK138600MD5 TK138800MD4 TK138800MD5 K Frame -- 1200 Amperes Maximum, Interchangeable Trip3,4 800 2000 4000 TK13A10MD5 800 2000 4000 TK13A12MD5 MOLDED CASE CIRCUIT BREAKERS Trip Unit Only TK38300TMD3 TK38400TMD4 TK38600TMD4 TK38600TMD5 TK38800TMD4 TK38800TMD5 1The lugs recommended for use with all Mine Duty breakers are copper for use with copper cable. Select from page 3-101. 2Applies only to magnetic-only breakers. 3Order frame plus trip unit; not available as complete breaker. 4Not suitable for use on dc. Accessories: See pages 3-85 to 3-104. 3 3-76 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Replacement Breakers TriBreak Internally Fused TB1 TB4 TB6 TB1, 150A Frame, Noninterchangeable Trip (Includes line and load lugs) Adjustable Instantaneous Trip Amperes Range Low High 15 20 25 30 35 40 45 50 60 70 80 90 100 100NA Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed - TB13015BWE05 TB13020BWE05 TB13025BWE05 TB13030BWE05 TB13035BWE05 TB13040BWE05 TB13045BWE05 TB13050BWE09 TB13060BWE09 TB13070BWE09 TB13080BWE09 TB13090BWE09 TB13100BWE09 TB13BYWE095,6 GO-135B Lugs2 Product No. and Wire Sizes (order 2 per pole) $2680.004 $2680.004 $2680.004 $2680.004 $2680.004 $2680.004 $2680.004 $2680.004 $2680.004 $2680.004 $2680.004 $2680.004 $2680.004 $2680.004 TCAL14 #14-8 Cu-Al TCAL 12 #14-2/0 Cu-Al TCAL 12 #14-2/0 Cu-Al List Price Trip Units3 Product Number List Price Lugs Furnished with Breaker Lugs Furnished with Breaker Replacement Current Limiters1 Standard Optional1 Product List Product Number Price Number TB4E05 $280.004 Not Available TB7E09 $360.004 TB4E05 TB4, 400A Frame, Interchangeable Trip (Without line or load lugs) Ampere Rating 125 150 175 200 225 250 300 350 400 400NA Adjustable Instantaneous Trip Amperes Range Low High 375 450 525 600 675 750 900 1050 1200 - 1250 1500 1750 2000 2250 2500 3000 3500 3500 - Tri-Break--Including Current Limiters1 Three-Pole Product List Number Price TB43125AF14 TB43150AF14 TB43175AF14 TB43200AF14 TB43225AF14 TB43250AF14 TB43300AF14 TB43350AF14 TB43400AF14 TB43AYW F145,6 $4079.00 $4079.00 $4079.00 $4079.00 $4079.00 $5542.00 $5542.00 $5542.00 $5542.00 $4802.00 $280.004 GO-135B Lugs2 Product No. and Wire Sizes (order 2 per pole) List Price $14.00 TCAL43 TCAL43 (1) 6-600 kcmil (1) 6-600 kcmil $14.00 or or (2) 2/0-250 kcmil (2) 2/0-250 kcmil - List Price - Trip Units3 Product Number List Price TB43T125 TB43T150 TB43T175 TB43T200 TB43T225 TB43T250 TB43T300 TB43T350 TB43T400 - $473.00 $473.00 $473.00 $473.00 $473.00 $1931.00 $1931.00 $1931.00 $1931.00 - Replacement Current Limiters1 Standard Optional1 Product List Product Number Price Number TB10F14 $377.00 TB3F05 or TB6F09 List Price $401.00 $377.00 3 1Standard current limiters (bolt on: TB1, TB6, TB8 and plug-in: TB4) have been selected based upon recommended coordination with thermal magnetic trip characteristics of the breaker. Optional current limiters are not UL listed in combination with breaker except TB4 with TB3F05 or TB6F09, 250A maximum. 2For optional lugs, see page 3-101. 3Trip units fit 2 and 3 pole frames. 4GO-148D. 5Molded case switch. Includes dummy trip, line and load lugs. 6Not UL listed. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog MOLDED CASE CIRCUIT BREAKERS Ampere Rating Tri-Break--Including Current Limiters1 Three-Pole Product List Number Price 3-77 Prices and data subject to change without notice Molded Case Circuit Breakers Replacement Breakers TriBreak Internally Fused TB6, 600A Frame, Interchangeable Trip (Without line or load lugs) Ampere Rating 300 350 400 500 600 600NA Adjustable Instantaneous Trip Amperes Range Low High 1200 1200 1200 1200 1200 - 3500 3500 3500 3500 3500 - TB63300BJ14 TB63350BJ14 TB63400BJ14 TB63500BJ14 TB63600BJ14 TB63BYWJ144 GO-135B Lugs2 Tri-Break--Including Current Limiters1 Three-Pole Product List Number Price Product No. and Wire Sizes (order 2 per pole) $7123.00 $7123.00 $7123.00 $7123.00 $7123.00 $6894.00 TCAL61 TCAL61 (2) 2/0-500 (2) 2/0-500 kcmil kcmil - List Price $40.00 40.00 - Trip Units3 Product Number List Price TB63T300 TB63T350 TB63T400 TB63T500 TB63T600 - $2334.00 $2334.00 $2334.00 $2334.00 $2334.00 - Replacement Current Limiters1 Standard Optional1 Product List Product Number Price Number TB10BJ14 $543.00 TB3BJ05 or TB6BJ09 TB8, 800A Frame, Interchangeable Trip (Without line or load lugs) Ampere Rating 600 700 800 800NA Adjustable Instantaneous Trip Amperes Range Low High 1800 2100 2400 - 3000 4000 4000 - TB83600BK22 TB83700BK22 TB83800BK22 TB83AYWK224,5 Product No. and Wire Sizes (order 2 per pole) $8204.00 $8204.00 $8204.00 $8204.00 $579.00 $543.00 GO-135B Lugs2 Tri-Break--Including Current Limiters1 Three-Pole Product List Number Price List Price TCAL81 (3) 250-500 kcmil - List Price $47.00 - Trip Units3 Product Number List Price TB83T600 TB83T700 TB83T800 - $2334.00 $2334.00 $2334.00 - Replacement Current Limiters1 Standard Optional1 Product List Product Number Price Number TB15K22 543.00 TB6BJ095 or TB10BJ145 List Price $543.00 $543.00 MOLDED CASE CIRCUIT BREAKERS Old Style (Plug-in) Replacement Limiters Replacement Limiter1 Breaker Type Ampere Range Standard TB1 TB1 TB1 TB6 TB8 15-45 50-100 110-150 300-600 600-800 TB3E05 TB6E09 TB7E10 TB10J14 TB15K18 Optional1 TB3E05 TB3J05 - TB7E09 TB6J09 - 1Standard current limiters (bolt on: TB1, TB6, TB8 and plug-in: TB4) have been selected based upon recommended coordination with thermal magnetic trip characteristics of the breaker. Optional current limiters are not UL listed in combination with breaker except TB4 with TB3F05 or TB6F09, 250A maximum. 2For optional lugs, see page 3-101. 3Trip units fit 2 and 3 pole frames. 4Molded case switch. Includes dummy trip, line and load lugs. 5Not UL listed. 6GO-135S. 3 3-78 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Replacement Breakers THLC Current Limiting Unfused 15-400 Amperes 20kAIC @ 240 Vac max. 20kAIC @480 Vac max. 50kAIC @600 Vac max. Ampere Rating 3-Pole Product Number 15 20 30 40 50 60 70 80 90 100 125 150 THLC136015WL THLC136020WL THLC136030WL THLC136040WL THLC136050WL THLC136060WL THLC136070WL THLC136080WL THLC136090WL THLC1360100WL THLC1360125WL THLC1360150WL GO-135B List Price $2910.00 $2910.00 $2910.00 $2910.00 $2910.00 $2910.00 $2910.00 $2910.00 $2910.00 $2910.00 $5520.00 $5520.00 Internal accessories for THLC1 are same as Type TED accessories. Refer to pages 3-86 to 3-91. THLC2, 225A Frame, 125-225 Amperes, Noninterchangeable Trip with Line and Load Lugs Ampere Rating 125 150 175 200 225 Adjustable Trip Range Amperes Low High 550 675 775 900 1000 1250 1500 1750 2000 2500 THLC1 GO-135B 3-Pole Product Number List Price THLC236125WL THLC236150WL THLC236175WL THLC236200WL THLC236225WL $5540.00 $5540.00 $5540.00 $5540.00 $5540.00 Internal accessories for THLC2 and THLC4 are same as Type TFK accessories. Refer to pages 3-87 to 3-91. Accessory must have code date 535+ or later. THLC4, 400A Frame, 250-400 Amperes, Noninterchangeable Trip without Line and Load Lugs 1 GO-135B THLC2 Adjustable Trip Range Amperes Ampere Rating Low High 3-Pole Product Number List Price 250 300 350 400 1175 1400 1650 1870 2500 3000 3500 4000 THLC436250 THLC436300 THLC436350 THLC436400 $7450.00 $7450.00 $7450.00 $7450.00 3 1Lug kit for THLC4 for line or load end. Order Product Number TCLK43, List Price $49.00, GO-135B. Consists of three-pole assembly. Wire range (1) 3/0-500 or (2) 3/0-250 Cu-Al. THLC4 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com MOLDED CASE CIRCUIT BREAKERS THLC1, 150A Frame, 15-150 Amperes, Noninterchangeable Trip with Line and Load Lugs BuyLog Catalog 3-79 Prices and data subject to change without notice Molded Case Circuit Breakers Replacement Breakers J and K Frame Circuit Breakers with MicroVersaTrip Plus Trip Units For Replacement Use Only For New Breaker Designs, use Spectra RMS Breakers with MicroVersaTrip Plus How To Order Pricing Example --Determine the required breaker frame (i.e. 600 or 1200 amperes), IC rating, and load requirements (UL Standard or 100%). Select frame product number and list price from table below. --Select and price the appropriate trip unit from table below. --Select and price the required rating plug from table below. The sensor rating of frame must match the sensor rating of the rating plug in table. --Select and price lugs and lug covers as required from pages 3-101 and 3-102. --When ordering, specify separate product numbers as follows. The trip unit will be installed in the frame. Rating plugs and lugs/lug covers will be shipped unassembled. --Frame --Trip Unit --Rating plug --Lugs/Lug covers --Other accessories (assembled or separate items) J600 frame, 300 ampere sensor, 250 ampere rating plug, 35kAIC, 480 Vac, IC 100% rated, trip unit functions to include long-time (L), short-time (S), instantaneous (I), ground fault (G), trip targets (T2), ground fault/short-time zone selective interlocking (Z2), 3-phase/3-wire system. Product Number Description Frame Trip Unit and Suffix Adder Rating Plug Zone Interlock Module (120 Vac) Neutral Current Sensor List Price, GO-135D TJH3SS TS20LSIGT2Z2 TR3S250J TIM1 TSRG203 $4774.00 $4915.00 $106.00 $402.001 $532.002 1GO-245B. 2GO-135S. MicroVersaTrip Plus Trip Unit Characteristics Long-Time 2 Current Setting (Multiple of rating plug ampere) (X) MOLDED CASE CIRCUIT BREAKERS 1.0, .95, .90, .85, .80, .70, .60, .50 Short-Time Delay (Seconds) Pick-Up (Multiple of Current Setting) (C) 2.4, 4.9, 9.8, 20 at 600% of current setting at lower limit of each band 1.5, 2.0, 2.5, 3.0, 4.0, 6.0, 7.0, 9.0 Delay (Seconds) I2t in;3 .44 I2t out:5 .10, .21, .35 Adjustable Instantaneous Pick-Up (Multiple of Rating Plug Amperes) (X) Ground Fault Pick-Up (Multiple of Sensor Ampere Rating) (S) 1.5, 2.0, 3.0, 5.0, 7.0, 9.0, 10.0 without short-time 1.5, 2.0, 3.0, 5.0, 7.0, 9.0, 10.0, 13.0, 15.0 6 with short-time .20, .25, .30, .35, .40, .45, .50, .60 Delay (Seconds) I 2t in;4 .44 I 2t out:5 .10, .21, .35 2 Pick-up fixed at 1.1C. 3 Time delay at 600% of current setting at lower limit of band. 4Time delay at 200% of pick-up setting at lower limit of band. 5 Time delay shown at lower limit of each band. Pick-up tolerances 10%. Ground fault pick-up not to exceed 1200 amperes. 6 J600 frame with 600 amp sensor for high IC 65kA rating (TJL) limited to 10X . X = rating plug amperes S = sensor ampere rating C = current setting 3 Circuit Breaker Frame Selection (less lugs) Frame Type J600 K1200 Sensor Rating (Amperes) 150 300 400 600 800 1200 65 kAIC Product Number TJL1S TJL3S TJL4S TJL6S TKL8S TKL12S GO-135D List Price $5149.00 $5149.00 $5149.00 $6222.00 $8603.00 $12536.00 100% 65 kAIC Product Number TJL1SS TJL3SS TJL4SS TJL6SS TKL8SS TKL12SS List Price $5919.00 $5919.00 $5919.00 $7155.00 $9892.00 $14414.00 Hi-Break Product Number TJH1S TJH3S TJH4S TJH6S TKH8S TKH12S List Price 100% Hi-Break7 Product Number $4151.00 $4151.00 $4151.00 $5018.00 $6935.00 $10108.00 TJH1SS TJH3SS TJH4SS TJH6SS TKH8SS TKH12SS List Price $4774.00 $4774.00 $4774.00 $5771.00 $7975.00 $11624.00 7100% supplied with back-connected assembly which increases breaker depth. Refer to outline drawing 139C4335 Sh7 for details. 3-80 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Replacement Breakers J and K Frame Circuit Breakers with MicroVersaTrip Trip Units For Replacement Use Only For New Breaker Designs, use Spectra RMS Breakers with MicroVersaTrip Plus J/K Rating Plug Selection--All plugs List Price, $106.00 Frame Type Sensor Rating (Amperes) Current Rating (Amperes) Rating Plug Product Number 60 80 100 125 150 150 200 225 250 300 150 200 225 250 300 400 TR1S60J TR1S80J TR1S100J TR1S125J TR1S150J TR3S150J TR3S200J TR3S225J TR3S250J TR3S300J TR4S150J TR4S200J TR4S225J TR4S250J TR4S300J TR4S400J 150 J600 GO-135D 300 400 Frame Type Sensor Rating (Amperes) J600 600 K800 800 K1200 1200 Current Rating (Amperes) Rating Plug Product Number 300 400 450 500 600 300 400 500 600 700 800 TR6S300J TR6S400J TR6S450J TR6S500J TR6S600J TR6S300K TR6S400K TR6S500K TR6S600K TR6S700K TR6S800K 600 800 1000 1200 TR12S600K TR12S800K TR12S1000K TR12S1200K Trip Unit Function Definitions Short-Time (S) Instantaneous (I) Ground Fault (G) Trip Indication Target (T1, T2) Zone Selective Interlock (Z1, Z2) Adjustable current setting Adjustable long-time delay Adjustable short-time pick-up Adjustable short-time delay with l2t Adjustable short-time delay without l2t Adjustable pick-up Adjustable ground fault pick-up Adjustable ground fault delay with l2t Adjustable ground fault delay without l2t Overload/short circuit targets (T1) Overload/short circuit/ground fault targets (T2) Ground fault (Z1) Ground fault/short-time (Z2) MOLDED CASE CIRCUIT BREAKERS Long-Time (L) 3 MicroVersaTrip Trip Unit Selection GO-135D Targets Trip Unit Suffix TS20LIT1 TS20LSIT1 TS20LIGT2 TS20LSIGT2 TS20LIGT2Z1 TS20LSIGT2Z1 TS20LSIGT2Z2 Zone Interlock List Price Long-Time (L) Short-Time (S) Instantaneous (I) Ground Fault1 (G) OL, SC (T1) OL, SC, GF (T2) GF (Z1) GF, ST (Z2) $755.00 $2120.00 $2380.00 $3745.00 $3965.00 $4330.00 $4915.00 * * * * * * * - * - * - * * * * * * * * * - - * * * * * * * - - * - - - - * * - * * - - - - * * - - - - - - - * 1For single-phase, 3-wire or three-phase, 4-wire applications select appropriate neutral-current sensor from page 3-103. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-81 Prices and data subject to change without notice Molded Case Circuit Breakers Replacement Breakers J and K Frame Circuit Breakers with Power+ 4 Trip Unit Part Number Selection Instructions 1. Select product number of circuit breaker, including trip unit suffix. 2. Select lugs, internal/external accessories and neutral current sensor, as required from pages 3-85 through 3-104. Power+ Trip Unit Characteristics Current Setting (Multiple of Frame Max. Sensor Current Sensor Current Type Amperes Ratings (Amperes) Rating) (X) Pick-up (Multiple of Current Setting) (C) .5, .6, .7, .8, .9, .9.5, 1.0 J600 600 150, 200 300, 400, 500, 600 K1200 1200 800, 1000, 1200 Short-Time 1,2 Long-Time (X) Fixed Sensor .5, .6, .7, .8, .9, .95, 1.0 (X) Delay 3 (Seconds) Pick-up (Multiple of Current Setting) (C) I 2t Delay Ramp 3 (Seconds) 3, 6, 12, 25 Bands 1, 2, 3, 4 1.5, 2, 2.5, 3, 4, 5, 7, 9 (C) .13, .26, .42 (Min, Int, Max) Adjustable Instantaneous Pick-Up 1 (Multiple of Sensor Current Rating (X) Pick-Up (Multiple of Sensor Current Rating) (X) 1.5, 2, 3, 4, 5, 7, 9, 10 (X) .2, .25, .3, .35, .4, .45, .5, .6 (X) Ground Fault 2 Delay 4 (Seconds) 0.10, 0.21 0.35 (Min, Int, Max) 1 When optional adjustable short-time pick-up is provided, instantaneous is fixed at 15X. Short-time and fixed instantaneous are not available on TJL with 500A and 600A sensors. 2 Delay Curve = I 2 t in, I 2 t out 3 Time delay shown at 600% of current setting at lower limit of each band. 4 Time delay shown at lower limit of each band. All pick-up tolerances are 10%. Ground Fault Pick-up not to exceed 1200 amperes. X = sensor current rating C = current setting Select trip unit product number from specific circuit breaker pages--J and K frames, page 3-81. Circuit Breaker Product Number Selection (less lugs) 5 Standard Circuit Breaker MOLDED CASE CIRCUIT BREAKERS Frame Type 3 Base Product No. None N G NG Base Product No. None N G NG 150 TJ4V2601A $2703.00 $2703.00 $3909.00 $3909.00 THJ4V2601A $3858.00 $3858.00 $5064.00 $5064.00 J600 K1200 Hi-Break Current Sensor Ampere List Price, GO-148D with Suffix 200 TJ4V2602A $2703.00 $2703.00 $3909.00 $3909.00 THJ4V2602A $3858.00 $3858.00 $5064.00 $5064.00 300 TJ4V2603A $2703.00 $2703.00 $3909.00 $3909.00 THJ4V2603A $3858.00 $3858.00 $5064.00 $5064.00 400 TJ4V2604A $2703.00 $2703.00 $3909.00 $3909.00 THJ4V2604A $3858.00 $3858.00 $5064.00 $5064.00 500 TJ4V2605A $3657.00 $3657.00 $4863.00 $4863.00 THJ4V2605A $4611.00 $4611.00 $5816.00 $5816.00 $5816.00 600 TJ4V2606A $3657.00 $3657.00 $4863.00 $4863.00 THJ4V2606A $4611.00 $4611.00 $5816.00 800 TK4V4608A $4694.00 $4694.00 $5900.00 $5900.00 -- -- -- -- -- 1000 TK4V4610A $8183.00 $8183.00 $9389.00 $9389.00 -- -- -- -- -- 1200 TK4V4612A $8183.00 $8183.00 $9389.00 $9389.00 -- -- -- -- -- Circuit Breaker Product Number Selection (less lugs) 5,6 Power+ 4 Trip Unit Selection Trip Unit Functions 65 kAIC Breaker Frame Type K1200 Suffix None W G NG Adjustable Current Setting * * * * Fixed Long-Time Pick-Up * * * * * Current Sensor Ampere Base Product No. None N G NG 150 TJL4V2601A $4242.00 $4242.00 $5448.00 $5448.00 Fixed Long-Time Delay * * * 200 TJL4V2602A $4242.00 $4242.00 $5448.00 $5448.00 Long-Time Timing Light * * * * 300 TJL4V2603A $4242.00 $4242.00 $5448.00 $5448.00 Adj. Short-Time Pick-Up -- * -- * 400 TJL4V2604A $4242.00 $4242.00 $5448.00 $5448.00 Fixed Short-Time Delay I2t Ramp -- * -- * 500 TJL4V2605A2 $5071.00 7 $6275.00 7 * -- * -- 600 TJL4V2606A2 $5071.00 7 $6275.00 7 800 TKL4V4608A $5658.00 $5658.00 $6864.00 $6864.00 1000 TKL4V4610A $9154.00 $9154.00 $10360.00 $10360.00 List Price, GO-148D with Suffix Long-Time J600 List Price, GO-148D with Suffix 1200 TKL4V4612A $9154.00 $9154.00 $10360.00 $10360.00 5 For single-phase, 3-wire or three phase, 4-wire applications, select appropriate neutral-current sensor from page 3-103. Short-Time Adj. Instantaneous Pick-Up Instantaneous Ground Fault5 Fixed Instantaneous Pick-Up7 -- * -- * Adj. Ground Fault Pick-Up Zero Sequence -- -- * * Adj. Ground Fault Delay -- -- * * 7 TJL4V with 500 and 600A sensors available with adjustable instantaneous only. 6Select and price lugs and lug covers as required from pages 3-101 and 3-102. * = Function included. 3-82 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Internal Accessories Spectra RMS Circuit Breakers Universal Field-Installable Internal Accessories All Spectra RMS circuit breakers from the SE150 through the SK1200, including instantaneous-trip Mag Break motor circuit protectors and molded case switches, use the same UL listed, field-installable internal accessories that do not require cover removal to install. Accessory Mounting All accessories mount in pouches accessible from a front cover. All breakers have a left-side pouch and right-side pouch. The following combinations may be installed: Left Side Pouch Left-Side Pouch--either shunt trip or undervoltage release plus bell alarm. Right-Side Pouch--auxiliary switch (single or double pole). Auxiliary Switch GO-135S Auxiliary switches provide remote indication of whether the circuit breaker main contacts are opened or closed via open or closed SPDT switch elements. Switch Rating 5A @240 Vac/ 0.5A @ 125 Vdc Gold-Plated Contacts 0.5A @ 30V One each of above types Number of Switch Elements 1 form C 2 form C 1 form C 2 form C 2 form C Auxiliary Switch Product Number SAUXPAB1 SAUXPAB2 SAUXGAB1 SAUXGAB2 SAUXGPAB2 List Price $149.00 $295.00 $149.00 $295.00 $295.00 Right Side Pouch Red White Brown/white Shunt Trip MOLDED CASE CIRCUIT BREAKERS All accessory contacts shown with the circuit breaker in tripped position. GO-135S For remote tripping of breaker, use with momentary close contact. Not recommended for use with latching relay contact since electronics in shunt trip will pulse power to the coil if continuously energized, and breaker shunt tripping upon reclosure will be delayed 1-2 seconds at rated control voltage. (A short-circuit trip would be instantaneous.) Auxilliary Switch If maintained (latching relay) contact must be used and delayed shunt tripping is not acceptable, use small bell alarm in series with control power for SE150 and SF250 frames and auxiliary switch for SG600 and SK1200 breakers. These devices are suitable for use with ground fault sensing and relaying equipment. Maximum VA is 75. AC devices are UL listed for 50-60 Hz. Voltage Current (mA) ac dc Inrush Cont Product Number List Price 120 240 12 24 48 125 250 12 24 48 500 400 1000 300 300 6.0 5.0 800 10.0 10.0 SAST1 SAST2 SAST51 SAST3 SAST4 $363.00 $363.00 $363.00 $363.00 $363.00 1Not suitable for use with ground fault sensing and relaying equipment. Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories. Black Black All accessory contacts shown with the circuit breaker in tripped position. Shunt Trip Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-83 Prices and data subject to change without notice 3 Molded Case Circuit Breakers Internal Accessories Spectra RMS Circuit Breakers Undervoltage Release GO-135S The undervoltage release provides automatic circuit breaker tripping when there is a power loss or major dip (to 35%-70% of rated voltage) in accessory control voltage. AC devices are UL listed for 50-60 Hz. Product number SAUV1 may be used with time delay unit SPUVTD (List Price $430.00, GO-245B) (delay 0.1 to 1.0 seconds), 120 Vac input, 125 Vdc output. Voltage ac 120 240 24 48 120 Peak Current (mA) 200 200 100 100 dc 125 250 24 48 125 Product Number SAUV1 SAUV2 SAUV3 SAUV4 SPUVTD List Price $363.00 $363.00 $363.00 $363.00 $430.001 1GO-245B. Undervoltage Release Blue All accessory contacts shown with the circuit breaker in tripped position. Blue Bell Alarm Switch GO-135S The bell alarm switch provides remote indication of whether the circuit breaker has been tripped via open or closed SPDT switch elements, but remains unchanged during "On/Off" circuit breaker operation and during operation by the "Push-to-Trip" button. MOLDED CASE CIRCUIT BREAKERS Switch Rating 5A @ 240 Vac/ 0.5A @ 125 Vdc Gold-Plated Contacts 0.5A @30V Number of Switch Elements Product Number List Price 1 form C SABAP1 $154.00 1 form C SABAG1 $154.00 Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories. Bell Alarm Switch Purple Yellow Brown All accessory contacts shown with the circuit breaker in tripped position. 3 3-84 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Internal Accessories Molded Case Circuit Breakers Internally mounted accessories can be either factory or field installed, but should be factory installed when UL listing is required. Pole Positions L--Left C--Center R--Right F225 frame accessories, including THLC2, and THLC4 are UL listed for field installation1. Lead Wire Exit S--Side B--Back Accessory Devices and Ratings Factory installed devices with leads exiting from the side are UL listed, but when leads exit from the back the UL listing is void. For accessory installation combinations refer to table below. "Mounting Pole" refers to left-, center- or right-hand pole as seen when facing the front of the breaker. Control leads may exit the breaker from its side (S) or back (B) 2. J Frame Circuit Breaker with Internal Accessories Mounted in Each Pole Nonautomatic circuit breakers (molded case switches) require dummy trip units if internal accessories are to be field installed (refer to page 3-91). L C R Inst. Sheet GEH- TQB, THQB, THHQB, TXQB, TQL, THQL, THHQL, TXQL, TQC, THQC, THHQC, TXQC -- -- -- TQD, THQD -- -- E150 TEB, TEC, TED, THED, THLC1, TB15,6,8 UL 7 F2259 TFC, TFJ, TFK, THFK, THLC2, THLC4, TLB2, TLB4 R Inst. Sheet GEH- L R Inst. Sheet GEH- -- -- -- -- -- -- One accessory only. Mounts in a one-inch frame and increase overall breaker size by one pole. May be applied to 1-, 2-, or 3-pole breakers. 4 -- -- -- -- -- -- One accessory only UL 3418 Aux 3416 S.T. -- UL 3417 -- UL8 3434 2-pole circuit breaker--any one 3-pole circuit breaker-- any two except UVR and 3-coil shunt trip UL UL 4653 UL UL 4653 UL8 UL 4622 any two 3320 UL UL 3321 Aux 3435 S.T. -- UL 5407 UL8 -- 3346 Any two plus belt alarm except TB4, TBC4 any one plus bell alarm. -- 4305 UL UL 3321 Aux 3344 S.T. -- UL 5408 UL8 -- 3346 Any two plus bell alarm -- 4626 -- UL 4623 Aux 4623 S.T. -- UL 4623 -- -- -- Any one plus bell alarm Mounting Pole L R -- UL -- -- -- -- UL -- UL 4576 UL 7 -- -- UL 4620 J600 TJC, TJD, TJJ, TJK, THJK, TB45, TBC45 -- UL8 -- K1200 TKC, TKM, THKM TB65, TBC65, TB8, TBC8 -- UL8 TJ4V, TKL4V, TJH6S, TKL12S 8 solid-state trips -- UL Inst. Sheet GEH- Three Coil Shunt Trip L Mounting Pole Breaker Type Undervoltage Release 4 Mounting Pole Mounting Pole Red White Brown/white Accessory-Lead Color Coding10 Purple Yellow Brown Blue White Black Blue Black Blue Shunt Trip 3 Red Brown/white Auxiliary Switch Bell Alarm Switch Total Number of Accessories Within any One Circuit Breaker Undervoltage Release All accessory contacts shown with the circuit breaker in tripped position. Yellow Black Three-Coil Shunt Trip 1 Except TFC and TFJ, F225 line model 4 frames and trips (mfg. code date J101+ (1981 or later), and THLC2, THLC4, TLB4 are UL listed for field installation of most accessories. 2 Not UL listed. 3 600 Vac auxiliary switches are not UL listed. 4 Accessories are factory installed only. 5 UL listed at 200 AIC without internal accessories, 100 AIC with internally mounted accessories. 6 Accessories not available for single-pole TEB/TED frame. Use two-pole circuit breaker. 7 Left pole mounting not available for two-pole TEB, TED. 8 Not available with lead exit from the back of breaker. 9 UL listed interrupting capacity with accessories: 10 kAIC at 600 Vac, 22 kAIC at 480 Vac, 22 kAIC at 240 Vac. 10Leads are #18 125C Vulkene insulated. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog MOLDED CASE CIRCUIT BREAKERS Auxiliary Switch 3 or Shunt Trip Bell Alarm Switch 3-85 Prices and data subject to change without notice Molded Case Circuit Breakers Internal Accessories Internally Mounted Signaling and Controlling Functions How to Order For factory installation, specify breaker product number, accessory base number, and appropriate suffix. (Example: Product Number TJK436125WL, TJUV1RS, TJKASA2AB2LS specifies a type TJK breaker with factory installed undervoltage release in the right-hand pole and an auxiliary switch in the left-hand pole.) For field replacement, order the accessory by the base number only. Where this number ends in "R" or "L" right-hand and left-hand devices are physically different. Specify only one suffix letter per accessory product number when option is available. Nonautomatic circuit breakers require dummy trip units if internal accessories are to be mounted. Undervoltage Release Mine Duty Circuit Breaker Undervoltage Release Circuit Breaker Frame E MOLDED CASE CIRCUIT BREAKERS J K GO-135A Control Voltage Factory Installed1 Product Number Premium Duty List Price Field Replacement Product Number2 List Price 24 Vac 120 Vac 240 Vac 12 Vdc 24 Vdc 60 Vdc 24 Vac 120 Vac 230 Vac 12 Vdc 24 Vdc 60 Vdc 24 Vac 120 Vac 240 Vac 12 Vdc 24 Vdc 60 Vdc TEDMDVAS TEDMDVBS TEDMDVCS TEDMDVDS TEDMDVES TEDMDVFS TJMDVAS TJMDVBS TJMDVCS TJMDVDS TJMDVES TJMDVFS TKMDVAS TKMDVBS TKMDVCS TKMDVDS TKMDVES TKMDVFS $485.00 $485.00 $485.00 $485.00 $485.00 $485.00 $509.00 $509.00 $509.00 $509.00 $509.00 $509.00 $509.00 $509.00 $509.00 $509.00 $509.00 $509.00 TEMDVAS TEMDVBS TEMDVCS TEMDVDS TEMDVES TEMDVFS TJRMDVA TJRMDVB TJRMDVC TJRMDVD TJRMDVE TJRMDVF TKRMDVA TKRMDVB TKRMDVC TKRMDVD TKRMDVE TKRMDVF $485.00 $485.00 $485.00 $485.00 $485.00 $485.00 $526.00 $526.00 $526.00 $526.00 $526.00 $526.00 $526.00 $526.00 $526.00 $526.00 $526.00 $526.00 1Mounts in right pole only. "S" suffix-wires out the side of breaker. 2Replacement for standard and premium duty mine duty UVR, both old and new design. 3 3-86 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Internal Accessories Internally Mounted Signaling and Controlling Functions Auxiliary Switches GO-135B Unless otherwise noted switch is SPDT rated 6 amperes at rated ac voltage, 1/2 amperes at 125 Vdc, 1/4 amperes at 250 Vdc. TQB, THQB, THHQB, TXQB, TQL,2 THQL, THHQL, TXQL TQC, THQC, THHQC, TXQC2 TQD, THQD TEB, TEC, TB1 TED, THED,THLC18 TFC, TFJ, TFK, THFK,9 THLC2, THLC4, TLB2, TLB4 TJC, TJD, TJJ, TJK, THJK TB4, TBC4 TKM, THKM, TKC, TB6, TB8, TBC6, TBC8 TJ4V/TJL, TK4V/TKL TRL/TRP R Frame Base Number 13 TQAS2A14 5 $64.50 13 TQCAS2A14 5 1 1 2 1 2 1 2 3 4 1 2 3 4 1 2 3 4 2 4 1 2 3 4 5 6 7 8 9 10 11 12 TQDAS2AB1RS TEDAS2AB1R,L7,8 TEDAS2AB2R,L7,8 TFKASA2AB110 TFKASA2AB210 TJKASA2AB1R,L TJKASA2AB2R,L TJKASA2AB3R,L TJKASA2AB4R,L TB4ASA2AB1R,L TB4ASA2AB2R,L TB4ASA2AB3R,L TB4ASA2AB4R,L TKMAAS2AB1 TKMAAS2AB2 TKMAAS2AB3 TKMAAS2AB4 TVAS2AB2R10 TVAS2AB4R10 TPAS2AB110 TPAS2AB210 TPAS2AB310 TPAS2AB410 TPAS2AB510 TPAS2AB610 TPAS2AB7S10 TPAS2AB8S10 TPAS2AB9S10 TPAS2AB10S10 TPAS2AB11S10 TPAS2AB12S10 $77.50 $148.006 $148.00 $295.00 $148.00 $295.00 $148.00 $295.00 $439.00 $598.00 $148.00 $295.00 $439.00 $598.00 $148.00 $295.00 $439.00 $598.00 $297.0011 $553.0011 $251.0012 $503.0012 $534.0012 $562.0012 $623.0012 $680.0012 $924.0012 $1180.0012 $1215.0012 $1240.0012 $1300.0012 $1365.0012 Must Must Must Must Must Must N/A S S RS or LS RS or LS S S S S S S S S RS or LS RS or LS RS or LS RS or LS S S S S S S S S be Factory Installed be Factory Installed be Factory Installed be Factory Installed be Factory Installed be Factory Installed Control Voltage 600 Vac, 250 Vdc Maximum Not UL Listed Suffix1 Add to Base Product Base Number for Factory List Number Installation Price - - - - TEDAS6AB1R,L7,8 TEDAS6AB2R,L7,8 TFKASA6AB110 TFKASA6AB210 TJKASA6AB1R,L TJKASA6AB2R,L TJKASA6AB3R,L TJKASA6AB4R,L TB4ASA6AB1R,L TB4ASA6AB2R,L TB4ASA6AB3R,L TB4ASA6AB4R,L TKMAAS6AB1 TKMAAS6AB2 TKMAAS6AB3 TKMAAS6AB4 TVAS6AB2R TVAS6AB4R TPAS6AB1 TPAS6AB2 TPAS6AB3 TPAS6AB4 TPAS6AB5 TPAS6AB6 TPAS6AB7S Must TPAS6AB8S Must TPAS6AB9S Must TPAS6AB10S Must TPAS6AB11S Must TPAS6AB12S Must - - S S RS RS S S S S S S S S RS or LS RS or LS RS or LS RS or LS S S S S S S S S be Factory Installed be Factory Installed be Factory Installed be Factory Installed be Factory Installed be Factory Installed - - $179.00 $360.00 $167.00 $360.00 $179.00 $360.00 $530.00 $712.00 $179.00 $360.00 $530.00 $712.00 $179.00 $360.00 $530.00 $712.00 $341.0011 $657.0011 $251.0012 $503.0012 $534.0012 $562.0012 $623.0012 $680.0012 $924.0012 $1180.0012 $1215.0012 $1240.0012 $1300.0012 $1365.0012 1"S" suffix for wires out the side of breaker. For lead exit from back of breaker, replace suffix "S" with "B"" and multiply list price by 1.25. "B" suffix not UL listed. Not available with leads out the back for "Q Line". 2Not available on GFCI (5 ma) or Equipment Ground Fault (30 ma) breakers. 3Switch is SPST. Operates like "A" side of an "AB" contact and is rated six amperes at 120 Vac and three amperes at 24 Vac. 4Accessories mounted in a one-inch frame and increase overall breaker size by one pole added to left side. May be applied to 1-, 2-, or 3-pole breakers. Must be factory installed. MOLDED CASE CIRCUIT BREAKERS Breaker Type Number of SPDT Switch Elements Control Voltage 240 Vac, 250 Vdc Maximum UL Listed When Factory Installed Suffix1 Add to Base Product Number for Factory List Installation Price Maximum total breaker width is four poles. 5To order, specify both the accessory and breaker product number, e.g. THQL2130, TQASA1 identifies a 30 ampere, 2-pole plug-in breaker with a factory installed SPST auxiliary switch. 6GO-135F. 7Auxiliary switch mounts in right pole only on two-pole TEB, TED breakers. (Factory installed only.) 8Not available with "B" suffix-leads out back. 9Changes circuit breaker interrupting capacity to 10kAIC, 600 Vac; 22 kAIC, 240 and 480 Vac. 10UL listed for field installation. 11GO-135C. 12GO-145A. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-87 Prices and data subject to change without notice 3 Molded Case Circuit Breakers Internal Accessories Internally Mounted Signaling and Controlling Functions How to Order For field replacement, order base number only. For factory installation, order base number plus appropriate suffix. For a nonautomatic breaker (molded case switch) a dummy trip is required when installing either a shunt trip or UVR. Shunt Trip Remote Tripping - Trips breaker by remote control. Trip coil de-energized when breaker opens. Device meets UL requirements for service to ground fault system. Undervoltage Release Undervoltage release automatically trips breaker when applied coil voltage drops to 30 to 70 percent of rated value. Time-delay unit prevent nuisance tripping due to momentary loss of voltage. Separate externally mounted unit has 120 Vac input and 125 Vdc output. Used in conjunction with 125 Vdc undervoltage release which must be ordered separately. Product number SPUVTD for adjustable delay .1 to 1.0 seconds. List Price $430.00 GO-245B. Shunt Trip GO-135B Accessory Voltage Vac Vdc Breaker Type TQB, THQB, THHQB, TXQB, TQL, THQL, THHQL, TXQL Product Number1,2 -- UL Listed When Factory Installed Suffix Number3 Base Number Add to Base Product Number for Field Replacement for Factory Installation 120-240 12 24-48 120-240 TQC, THQC, THHQC, TXQ 120 240 TQD, THQD MOLDED CASE CIRCUIT BREAKERS 12 24 12 24 120 240 480 600 TEB, TEC, TB1-B,11 TED, THED, THLC1 12 24 48 125 250 TFC, TFJ, TFK, THFK, THLC2, THLC4, TLB2, TLB4 120 240 480 600 3 12 24 48 125 250 TQSTA14,5,6,7 TQSTA74,6,7 TQSTA84,6,7 TQCSTA14,6 TQCSTA74,6 TQCSTA84,6 TQDSTA8,9 TQDSTA29 TQDSTA79 TQDSTA89 TEDST12 TEDST12 TEDST13 TEDST13 TEDST7 TEDST8 TEDST9 TEDST12 TEDST11 TFKSTA121 TFKSTA121 TFKSTA131 TFKSTA131 TFKSTA71 TFKSTA81 TFKSTA91 TFKSTA121 TFKSTA111 10 10 10 10 10 10 10 10 10 10 RS or LS8,12 RS or LS8,12 RS or LS8,12 RS or LS8,12 RS or LS8,12 RS or LS8,12 RS or LS8,12 RS or LS8,12 RS or LS8,12 RS or LS RS or LS RS or LS RS or LS RS or LS RS or LS RS or LS RS or LS RS or LS List Price $95.50 $95.50 $95.50 $112.00 $112.00 $112.00 $178.00 $178.00 $178.00 $178.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4. 2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1. for 120 Vac UVRs on all other breaker lines, order Product Number 192A8300G1. 3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed. Not available with leads out the back on "Q Line." 4Mounts on a one-inch frame and increases overall breaker size by one pole added to left side. May be applied to 1-, 2-, or 3-pole breakers. Maximum total breaker width is 4-pole. Must be factory installed. 5A selective listing of breaker product numbers that include 120 Volt ac shunt trip appears on page 3-14. 6Not available on GFCI (5 ma) or Equipment Ground Fault (30 ma) breakers. 7TQST shunt trips not available on breakers over 100 A. 8Not available with "B" suffix-leads out back. 9Must be factory installed, right pole only. 10To order, specify both the accessory and breaker product number =, e.g.THQL2130, TQST1 identifies a 30 A, 2-pole plug-in breaker with a factory installed 120 Vac shunt trip. 11For TB1 with bolt-on limiters. 12Mounts in the right pole only on 2-pole TEB, TED breakers. 3-88 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Internal Accessories Internally Mounted Signaling and Controlling Functions Shunt Trip (continued) GO-135B Vac Vdc 120 240 480 600 TJC, TJD, TJJ, TJK, THJK 12 24 48 125 250 120 240 480 600 TB4, TBC4 TKC, TKM, THKM, TB6, TB8, TBC6, TBC84 TJ4V, TKL4V, TJH6S, TKL12S R Frame TRL, TRP 12 24 48 125 250 120 240 480 600 12 24 48 125 250 120 240 480 600 12 24 48 125 250 120 240 480 600 12 24 48 125 250 TJKSTA12R,L TJKSTA12R,L TJKSTA13R,L TJKSTA13R,L TJKSTA7R,L TJKSTA8R,L TJKSTA9R,L TJKSTA12R,L TJKSTA11R,L TB4STA12R,L TB4STA12R,L TB4STA13R,L TB4STA13R,L TB4STA7R,L TB4STA8R,L TB4STA9R,L TB4STA12R,L TB4STA11R,L TKMASTA12R,L TKMASTA12R,L TKMASTA13R,L TKMASTA13R,L TKMASTA7R,L TKMASTA8R,L TKMASTA9R,L TKMASTA12R,L TKMASTA11R,L TVST12R TVST12R TVST13R TVST13R TVST7R TVST8R TVST9R TVST12R TVST11R TPST12R TPST12R TPST13R TPST13R TPST7R TPST8R TPST9R TPST12R TPST11R List Price S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.005 $363.005 $363.005 $363.005 $363.005 $363.005 $363.005 $363.005 $363.005 $630.006 $630.006 $630.006 $630.006 $630.006 $630.006 $630.006 $630.006 $630.006 1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4. 2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1. for 120 Vac UVRs on all other breaker lines, order Product Number 192A8300G1. 3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed. Not available with leads out the back on "Q Line." 4Not UL listed. 5GO-135C UL listed for field installation. 6GO-145A UL listed for field installation. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-89 Prices and data subject to change without notice MOLDED CASE CIRCUIT BREAKERS Accessory Voltage Breaker Type Product Number1,2 -- UL Listed When Factory Installed Suffix Number3 Base Number Add to Base Product Number for Field Replacement for Factory Installation 3 Molded Case Circuit Breakers Internal Accessories Internally Mounted Signaling and Controlling Functions UnderVoltage Release GO-135B Accessory Voltage Breaker Type Vac Vdc Product Number1,2 -- UL Listed When Factory Installed Suffix Number3 Base Number Add to Base Product Number for Field Replacement for Factory Installation 120 240 480 600 TEB, TEC, TB1-B5 TED, THED, THLC1 12 24 48 125 250 TFC, TFJ, TFK, THFK, THLC2, THLC4, TLB2, TLB4 120 240 480 600 12 24 48 125 250 120 240 480 600 TJC, TJD, TJJ, TJK, THJK 120 240 480 600 MOLDED CASE CIRCUIT BREAKERS TKC, TKM, THKM, TB6, TB8, TBC6, TBC86 3 12 24 48 125 250 12 24 48 125 250 120 240 480 600 TJ4V, TKL4V, TJH6S, TKL12S5 12 24 48 125 250 380 120 240 480 600 R Frame TRL, TRP5 12 24 48 125 250 TEDUV1 TEDUV2 TEDUV4 TEDUV6 TEDUV7 TEDUV8 TEDUV9 TEDUV10 TEDUV11 TFKUVA11 TFKUVA2 TFKUVA4 TFKUVA6 TFKUVA7 TFKUVA8 TFKUVA9 TFKUVA10 TDKUVA11 TJUV1R TJUV2R TJUV4R TJUV6R TJUV7R TJUV8R TJUV9R TJUV10R TJUV11R TKUV1R TKUV2R TKUV4R TKUV6R TKUV7R TKUV8R TKUV9R TKUV10R TKUV11R TVUV1R TVUV2R TVUV4R TVUV6R TVUV7R TVUV8R TVUV9R TVUV10R TVUV11R TVUV3R TPUV1 TPUV2 TPUV4 TPUV6 TPUV7 TPUV8 TPUV9 TPUV10 TPUV11 RS8 RS8 RS8 RS8 RS8 RS8 RS8 RS8 RS8 RS or LS RS or LS RS or LS RS or LS RS or LS RS or LS RS or LS RS or LS RS or LS S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S List Price $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.00 $363.007 $363.007 $363.007 $363.007 $363.007 $363.007 $363.007 $363.007 $363.007 $363.007 $630.008 $630.008 $630.008 $630.008 $630.008 $630.008 $630.008 $630.008 $630.008 1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4. 2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1 for 120 Vac UVRs on all other breaker lines, order Product Number 192A8300G1. 3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed. Not available with leads out the back on "Q Line." 4For TB1 with bolt-on limiters. 5Not available with "B" suffix - leads out back. 6Not UL listed. 7GO-135C UL listed for field installation. 8GO-145A UL listed for field installation. 3-90 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Internal Accessories Internally Mounted Signaling and Controlling Functions GO-135B Automatically trips breaker when an undervoltage or power outage condition occurs. Special PUSH-TO-TRIP/PUSH-TO-RESET button is used to manually trip the breaker (E-frame only). On J and K frames, the UVR is handle resettable with a cover-mounted button to provide local mechanical tripping. The Heavy-Duty Undervoltage Release (UVR) is designed for applications where repeated UVR trips are anticipated. The manual reset feature prevents breaker reset or possible contact kiss until power is available and reset button is depressed. Mounts in right pole of breaker only. Must be factory installed to incorporate special breaker frame modifications.2 Motor-operated mechanism cannot be provided when heavy-duty UVR is installed. TEB, TED, THED, TEC,TB14,5 TJJ, TJK, THJK, TJD, TJC, TB4, TBC4 TKM, THKM, TKC, TB6,TB8, TBC66, TBC86 ac dc Product Number3 List Price 24 120 240 - - - - 24 120 240 - - - 24 120 240 - - - - - - 12 24 60 125 - - - 12 24 60 - - - 12 24 60 TEDXUVARS13 TEDXUVBRS13 TEDXUVCRS13 TEDXUVDRS13 TEDXUVERS13 TEDXUVFRS13 TEDXUVGRS13 TJMDVAS TJMDVBS TJMDVCS TJMDVDS TJMDVES TJMDVFS TKMDVAS TKMDVBS TKMDVCS TKMDVDS TKMDVES TKMDVFS $543.00 $543.00 $543.00 $543.00 $543.00 $543.00 $543.00 $509.007 $509.007 $509.007 $509.007 $509.007 $509.007 $509.007 $509.007 $509.007 $509.007 $509.007 $509.007 GO-135B Product Number UL Listed When Factory Installed Base No. Suffix Breaker Type TEB, TEC, TB1 TED, THED, THLC1 TFC, TFJ, TFK, THFK, THLC2, THLC4, TLB4 TJC, TJJ, TJK, THJK TB4, TBC4, TJD TKC, TKM, THKM, TB6, TBC6, TBC8, TB8 List Price TEDBAR or TEDBAL5,8 S $154.00 $154.00 TFKBAAR9,10 S $154.00 TJKBAAL11 S $156.00 TKMABAAL11 S $141.00 TJL, TKL TJVBALS TKVBALS S $156.0012 $156.0012 (R Frame) TRL, TRP TPSBAS S $259.0013 Blown Fuse Detector-Three-Coil Shunt Trip GO-135B Product Number UL Listed When Factory Installed Base No. Suffix Breaker Type Voltage Breaker Type Bell Alarm Switches TED, THED, TEC5 TFJ, TJK, THFK, TFC TJJ, TJK, THJK, TJD, TJC TKM, THKM, TKC (R Frame) TRL, TRP TEDST316 TFKBFD316 TJKST316 TKMAST316 TPST316 RS LS or RS LS LS S Dummy Trip1 $672.00 $672.00 $672.00 $672.00 $1530.0013 GO-135B Breaker Type E150 FJ225 JJ400 FK225 FK225 JK400 JK600 KM800 KM1200 List Price Product Number List Price Internal accessories for these noninterchangeable breakers require factory-installed dummy trips. Automatically supplied when accessories are ordered. TFKYT2 (two-pole) TFKYT3 (three-pole) TJKYT3 (two-pole, three-pole) TJKYT36 (two-pole, three-pole) TKMAYT3 (two-pole, three-pole) TKMA3YT12 (two-pole, three-pole) No Charge $148.00 $208.00 $212.00 $212.00 $261.00 $424.00 1Not UL listed when field installed. 2For replacement purposes, order from page 3-84 using field replacement Product Number. 3Add "B" suffix for leads exit from back of breaker; for price, multiply List Price by 1.25. MOLDED CASE CIRCUIT BREAKERS Heavy-Duty Undervoltage Release1 4For TB1 with bolt-on limiters. 5Not available with "B" suffix - leads out back. 6Not UL listed. 3 7GO-135A. 8Not available for two-pole TEB, TED. Order TEDBAR. 9Changes circuit breaker interrupting capacity to: 10kA @ 600 Vac, 22kA @ 480 Vac, 22kA @ 240 Vac, for TFC, TFJ, TFK and THFK only. 10UL listed for field installation. 11Mounts in center pole with leads out left side. 12GO-135C. 13GO-145A. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-91 Prices and data subject to change without notice Molded Case Circuit Breakers External Accessories Cable Operators Spectra Flex Cable Operators --UL Listed--File E-57253 --Reduced installation costs: --Simpler, faster installation --No special alignment required --Optimized panel layout: --Breaker mounting position is independent of flange-mounted handle location --Covers a full spectrum of enclosure types and sizes: --Flange-mounted handle for NEMA Types 1, 3R, 12 and 13 enclosures --Flange-mounted handle for NEMA 4/4X enclosures--optional --Broad range of enclosure sizes and breaker mounting configurations --8 different operating cable lengths available from 3 to 10 feet --For circuit breaker types E150, SE150, SF250, SG600 and SK1200 --Force and motion transmitted independently of breaker mounting plane or position relative to handle location --Common breaker mounted operator for SE150 and SF250 frames MOLDED CASE CIRCUIT BREAKERS Spectra Flex cable operating mechanisms are suitable for application with GE circuit breakers mounted in a wide variety of flanged enclosure types and sizes. 3 Flange-mounted handle mechanisms are available for NEMA Types 1, 12 or 13 enclosures in either 6 inch (Model SCH1) or 10 inch (Model SCH2) handle lengths. Corresponding mechanisms, SCH1X and SCH2X, are available for NEMA Type 4/4X enclosures. Handle mechanisms are suitable for either left or right flange operation. The handle mechanism is combined with one of eight operating cables, with lengths from 3 to 10 feet, to cover a broad range of possible breaker mounting locations in the enclosure. The cable links the handle mechanism to the breaker-mounted operating mechanism and transmits the mechanical force and motion of the handle mechanism to the breaker mounted mechanism. The force and motion is transmitted independently of the breaker mounting plane or location relative to the location of the handle mechanism, provided only that the bending radius of the cable is not less than 3 inches. No mounting reinforcement of the breaker or enclosure flange is required. The breaker-operating mechanism mounts directly to the face of the breaker and does not involve any mounting interface with the enclosure. A standard breaker mounting screw kit for tapped holes is furnished with each mechanism to mount the breaker in the enclosure. See page 3-93 for ordering and pricing information. 3-92 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers External Accessories Cable Operators How to order Use the circuit breaker mounting zone dimension table to determine the correct cable length for the application and ensure that the 3-inch minimum bending radius is not violated. Select the breaker mounted mechanism, operating cable and handle mechanism below. Order as separate components. Publication References Breaker types E150, SE150, SF250, SG600 Breaker type SK1200 GEH-6290 GEH-6291 See Section 21 for publication ordering information. Maximum Dimensions in Inches To determine the maximum mounting dimensions for 60-through 120-inch-long operating cables, add the respective additional lengths to the 48-inch cable maximum dimensions. (Example: Add 12 inches to E, F and G dimensions for 60-inch cable length.) When cable is installed, the minimum cable bend radius should not be less than 3 inches. The minimum cable bending requirement must be met to ensure a safe operating environment. Maximum Mounting Dimensions (in.) 8" 10" 12" 16" 18" 20" 24" E1 36" Cable F G 13.5 13.0 12.8 10.5 8.5 - - 4.0 5.0 6.0 4.5 3.5 0.5 - 15.0 14.8 14.5 14.2 12.6 10.0 - Operating Cables E1 48" Cable F G 25.5 25.0 24.8 22.5 20.5 22.0 19.5 16.0 17.0 17.0 16.5 15.5 15.0 14.0 27.0 26.8 26.5 26.2 24.6 24.0 22.0 GO-144A Circuit Breaker Type Cable Length 3' 4' 5' 6' 7' 8' 9' 10' 1Maximum E Dimension only if F = 4.5" E150, SE150, SF250, SG600 Product List Number Price SC3L SC4L SC5L SC6L SC7L SC8L SC9L SC10L $91.00 $108.00 $119.00 $134.00 $148.00 $163.00 $196.00 $211.00 SK1200 Product Number List Price SC3H SC4H SC5H SC6H SC7H SC8H SC9H SC10H $119.00 $141.00 $163.00 $185.00 $207.00 $229.00 $251.00 $273.00 Breaker and Handle Mechanisms Flange-Mounted Handle Mechanism Circuit Breaker Type E150 SE150 SF250 SG600 SK1200 Breaker Mounted Mechanism Product List Price Number GO-144A SCOM1A SCOM1EF SCOM1EF SCOM1G SCOM1K $96.00 $133.00 $133.00 $148.00 $149.00 6" Product Number NEMA Enclosure Type 1, 3R, 12, 13 10" List Price Product GO-144A Number NEMA Enclosure Type 4, 4X 6" 10" List Price GO-144A Product Number List Price GO-144A Product Number List Price GO-144A SCH1 $188.00 SCH2 $322.00 SCH1X $258.00 SCH2X $373.00 - - SCH2K $322.00 - - SCH2KX $373.00 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog MOLDED CASE CIRCUIT BREAKERS Box Depth Circuit Breaker Mounting Zone Dimensions 3-93 Prices and data subject to change without notice 3 Molded Case Circuit Breakers External Accessories Flange-Mounted Operators Type STDA Flange Handles and Variable Depth Operating Mechanisms Flange Stiffener Kit or Extended Length Drive Rod, Product Number TDSR --Designed to meet automotive duty specifications --NEMA 12/13 and 4/4X UL Component Recognized components, File E-57253l CSA LR 10263 --For right or left hand flange mounting - field convertible --Mounting dimensions to fit standard flange enclosures 8 inches - 24 inches deep --Detailed installation instructions --Superior strength Provides rigid 3/8-inch diameter rod between STDA handle mounting surface (flange or center mullion) and operating mechanism when STDA handle would otherwise not be rigidly supported. Flange Handle Construction --Rugged die cast housing with provisions for locking in OFF position with up to three 3/16-inch to 5/16-inch padlocks --O-ring seals for dirt-tight/oil-tight duty --Gusseted, 3/32-inch thick double-sided steel handle with large, red-black self-extinguishing grade plastic grip. Rod length is 22 inches and my be cut to appropriate length. Also used as extended-length drive rod for SDOM1A and SDOM3 when standard 16 inch rod is not long enough. (Operating mechanism Product Number SDOM6 for SK1200 includes two 22" unique 3/8-16x22 inch flange stiffener rods, Product Number TDSR and drive rod.) Operating Mechanism Product Number GO-144A Product Number STDA1 (6 inch) and STDA2 (10 inch) flange series handles are interchangeable. While the SE150 through SG600 operating mechanisms can be easily operated with the 6-inch STDA1 handle, the 10-inch STDA2 may be used to obtain lower operating force and/or to provide a proportionally larger handle on large enclosures. STDA3 and STDA3X can be used only with SDOM6 (for SK1200) operating mechanism. MOLDED CASE CIRCUIT BREAKERS NEMA 12/13 Flange Handle Product Number 3 STDA1 STDA2 STDA3 List Price NEMA 4/4X Flange Handle Product Number List Price Nominal Length Inches Installation Instruction Number Drilling Template Number $82.50 $94.50 $94.50 STDA1X STDA2X STDA3X $148.00 $165.00 $165.00 6 10 10 GEH-5314 GEH-5314 Operating Mechanism Selection Circuit Breaker Type Flange Handle Product Number SE150 SF250 SG600 SK12001 TEB, TED, THED, TEC TB1 (150A), TEC with TECL THLC1 (150A) TFJ, TFK, TFC (225A) J-Frames, TJC (400, 600A)3 TB4 (400A) TJH/TJL4 (600A Max) K-Frames, TKC (800A, 1200A)5, THLC2 (225A), THLC4 TLB4 (400A) TB6 (600A), TB8 (800A) TKH/TKLD6 (1200A Max) GO-144A Operating Mechanism Product Number STDA1, 1X (6 inch) or STDA2, 2X (10-inch) STDA3, 3X STDA1, 1X (6 inch) or STDA2, 2X (10-inch) List Price SDOM1A SDOM3 SDOM4 SDOM61 SDOM1A SDOM1A SDOM1AP TDOM1D TDOM32 $67.00 $76.50 $194.00 $303.00 $67.00 $67.00 $15.00 $252.00 $76.50 TDOM4 $194.00 TDOM5 $265.00 TDOM6 $303.00 TDOM7 $303.00 Flange Stiffener Kit Product Number Extended Drive Rod Product Number List Price TDSR TDSR $29.50 TDSR1 $28.00 SDOM1A, SDOM3, TDOM1A through TDOM3 TDSR SDOM4, Flange Handle Selection GO-144A TDOM4 through TDOM7 (16" supplied with operating mechanism) Extended Drive Stud, Product Number TDS1, TDS2 GO-144A This optional drive study permits locating the operating mechanism 1-5/16 inches farther to the left (When flange handle is on right side) or to the right (when handle is on the left side) to accommodate specific mounting restrictions. Not suitable for use with SDOM4, SDOM6, TDOM4 and TDOM5 operating mechanisms. Operating Mechanism Product Number SDOM1A, SDOM3, TDOM1A through TDOM3 TDOM6, TDOM7 Extended Drive Stud Product Number List Price TDS1 $29.50 $29.50 TDS2 Door Hardware NEMA 12/13 and 4/4X GO-144A Type TDV door hardware provides sealing and interlocking of 3/4-inch nominal door depth hinged on left or right. Interlocking design requires use of screwdriver to release. When used with an STDA flange handle and operating mechanisms, disconnect or circuit breaker cannot be turned on unless door and door hardware have been closed. For noninterlocking type, one bracket in kit is not used. Use of third point latch recommended for doors 40 inches or longer. Description NEMA 12/13 two point interlocking door hardware kit NEMA 4/4X two point interlockingdoor hardware kit Third point latch kit for above Door Hinged on Left Product Number Door Hinged on Right Product Number List Price TDV1 TDV1L $134.00 TDV1X TDV1LX $174.00 TDV3 TDV3L $29.50 1Requires STDA3 or STDA3X (10 inch, SK1200 only). 2Not suitable for left hand mounting. 3Includes TJ/THJ/TJL with MicroVersaTrip R trip unit. 4Use TDOM5 for TJH/TJL with MicroVersaTrip R RMS-9 trip unit. 5Includes TK/TKL with MicroVersaTrip R trip unit. 6Use TDOM7 for TKH/TKL with MicroVersaTrip R trip unit. 3-94 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers External Accessories Flange-Mounted Operators Auxiliary Contact Kits GO-144A Available SPDT and DPDT and actuated by operating mechanism yoke. Used With Operating Mechanism Product Number When STDA handle is on Right Left Flange Flange SDOM1A, SDOM3 SDOM4 TDOM1A, JA TDOM1B, JB TDOM1C TDOM1D TDOM3 SDOM6 TDOM4 TDOM5 TDOM6 TDOM7 * * * * Auxiliary Contact Kit SPDT DPDT Product Number List Price Product Number List Price TDAS1L1 $71.00 TDAS1L2 $134.00 TDAS1R1 $71.00 TDAS1R2 $134.00 TDAS2L1 $71.00 TDAS2L2 $134.00 TDAS1R1 $71.00 TDAS1R2 $134.00 Publication References Instructions: Door Hardware Auxiliary Contact Kit Flange Stiffener Kit or Extended Length Drive Rod Extended Drive Stud GEH-5322 GEH-5323 GEH-5324 GEH-5325 Operating Mechanism: SDOM1A through SDOM4, SDOM6 TDOM1A through TDOM1D TDOM3 TDOM4 and TDOM5 TDOM6 and TDOM7 GEH-5684 GEH-5315 GEH-5317 GEH-5318 GEH-5319 MOLDED CASE CIRCUIT BREAKERS See Section 21 for publication ordering information. 3 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-95 Prices and data subject to change without notice Molded Case Circuit Breakers External Accessories Door-Mounted Operators TDM Operating Handle, Fixed or Adjustable Shaft TDM Handle Operating Mechanisms, Door Mounted GO-144A Complete mechanism with handle UL listed, E-57253 Operating mechanism only, UL Component Recognized, E-57253 Breaker Type TQD, THQD TEB, TEC, TB1, TED, THED TFC, TFJ, TFK, THFK MOLDED CASE CIRCUIT BREAKERS TJC, TJD, TJJ, TJK, THJK, TB4, TBC4 TKC, TKM, THKM, TB6, TBC6, TB8, TBC8 TJ4V, TJL TK4V, TKL SE150 (GEH-5611)5 SF250 (GEH-5611)5 3 SG600 (GEH-5653)5 Complete Mechanism1 with NEMA 1, 3R, 12 Handle Product List Number Price Box Depth in Inches Shallow Mount 3 7/16 Extended Shaft 4 5/16 - 14 5/16 Shallow Mount 4 3/16 Extended Shaft 5-1/8 - 5 7/32 5 1/8 - 5 13/16 5 1/8 - 15 Shallow Mount 5 7/8 Extended Shaft 6 7/8 - 15 1/2 Shallow Mount 5 7/8 Extended Shaft 5 5/8 - 15 5/8 Shallow Mount 7 7/16 Extended Shaft 7 1/32 - 17 5/16 Shallow Extended Shallow Extended 4 3/16 6 1/8 - 15 5 7/8 7 3/4 - 15 1/2 5 7/8 5 5/8 - 15 5/8 TQDHM1 6 SK1200 (GEH-5612)5 7 Operating Mechanism Only Product List Number Price $69.00 TQDOM1 $42.00 TQDHM2 $82.00 TQDOM22 $55.00 TEFHM1 $69.00 TEFOM1 $42.00 TEFHM3 $82.00 TEFOM3 $55.00 TEFHM4 TEFHM2 $82.00 $82.00 TEFOM4 TEFOM2 $55.00 $55.00 TFKHM1 $103.50 TFKOM1 $76.50 TFKHM2 $107.50 TFKOM22 $80.50 TJKHM1 $143.00 TJKOM1 $102.00 TJKHM2 $147.00 TJKOM24 $106.00 TKMHM1 $143.00 TKMOM1 $102.00 TKMHM2 $147.00 TKMOM24 $106.00 TJVHM1 TJVHM2 TKVHM1 TKVHM2 SEFHM1 SEFHM2 SEFHM1 SEFHM2 SGHM1 SGHM2 SKHM1 SKHM2 $143.00 $147.50 $143.00 $147.00 $79.00 $81.50 $79.00 $81.50 $143.00 $147.00 $143.00 $147.00 TJVOM1 TJVOM2 TKVOM1 TKVOM2 SEFOM1 SEFOM22 SEFOM1 SEFOM22 SGOM1 SGOM24 SKOM1 SKOM24 $102.00 $106.00 $102.00 $106.00 $52.00 $55.00 $52.00 $55.00 $102.00 $106.00 $102.00 $106.00 Handle Only NEMA 1, 3R, 12 Product List Number Price TH1 TH2 NEMA 4/4X Product List Number Price $27.00 THCH453,4 $303.00 - - - - - - - - THCH453,4 $303.00 $41.00 TH1 $7.00 TH2 $41.00 1Handle assembly and operating mechanism separately packaged. 2For 15-inch long shaft order Product Number 788A831G10, List Price, $40.00, GO-135B. For 20-inch long shaft order Product Number 788A831G21 List Price $40.00, GO-135B. 3Provides interlocking for J600, SG600 SK1200, and K1200 breakers when used with the extended shaft operating mechanism. For interlocking with E150/SE150, F225 and SF250 order special shaft Product Number 788A832G1, List Price, $40.00, GO-135B. 4For 15-inch long shaft order Product Number 788A832G2, List Price $40.00, GO-135B. For 20-inch long shaft order Product Number 788A832G5, List Price $40.00, GO-135B. 5Installation instructions publication number. 6MOD 1 is 7 7/16; MOD 2 is 8 3/32. 7MOD 1 is 7 3/16 - 17 3/16; MOD 2 is 7 15/16 - 17 15/16. Handle Accessories for TDM Operating Mechanisms Device Product Number Replacement neoprene gaskets for NEMA 1, 3R and 12 enclosures Use with TH1 Use with TH2 788A742P3 788A742P4 3-96 Prices and data subject to change without notice GO-139 List Price $2.80 $6.10 BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers External Accessories Door-Mounted Operators TDR Handle on TEC Mag-Break TDR Integral Handle Mechanism 1 Suitable for NEMA 12 Applications 2 Breaker Type TEB, TEC, TB1-B, TED, THED THLC1 TFC, TFJ, TFK, THFK THLC2, 4; TLB4 TJD, TJC, TJJ, TJK, THJK, TB4, TBC4 TKC, TKM, THKM, TB6, TB8, TBC6, TBC8 TJ4V, TJL TKL SE150, SF250 (GEH-5609)6 SG600 (GEH-5654)6 SK1200 (GEH-5610)6 Vertical Mounting Product Number Handle Horizontal Mounting Product Number TEFR1B TLC1RB TFKR1B TLC4RB TJR1B TKMR1B TJVR1B TJVR1BKLP4 TKVR1B TKVR1BKLP4 SEFR15 SGR1 SKR1 TEFR1HB TLC1RHB TFKR1HB TLC4RHB TJR1HB TKMR1HB TJVR1HB TJVR1HBKLP4 TKVR1HB TKVR1HBKLP4 SEFR1H5 SGR1H SKR1H GO-144 List Price Ship Weight $65.50 $65.50 $78.50 $78.50 $78.50 $128.00 $78.50 $524.00 $128.00 $572.00 $65.50 $78.50 $128.00 Door Ring - Interlock Catch Kit Product List Number Price NEMA 12 Gasket Kit Product List Number Price 173 173 223 3 5 5 SEFRDRCK - 343L483G5 343L483G9 343L483G2 SKRDRCK $11.25 - $11.25 $11.25 $20.25 $21.75 SEFRGSK $4.00 - SGRGSK SKRGSK - $11.00 $11.00 5 343L483G7 $20.25 SGRGSK $11.00 5 343L483G8 $21.75 SKRGSK $11.00 173 5 5 SEFRDRCK SGRDRCK SKRDRCK $11.25 $20.25 $21.75 SEFRGSK SGRGSK SKRGSK $4.00 $11.00 $11.00 1Not suitable for use with mine duty or heavy duty UVR breakers. 2Requires Gasket kit. 3Shipped 12 per pack. 4With provision for Kirk Key Interlock. Lock supplied by customer (type FN with one-inch bolt projection - bolt extended, key removable with breaker open). 5For F250 Frame also order adapter bracket, Product Number SFRAK, no charge when ordered with handle. MOLDED CASE CIRCUIT BREAKERS 6Installation instructions publication number. See Section 21 for publication ordering information. 3 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-97 Prices and data subject to change without notice Molded Case Circuit Breakers External Accessories Motor Operators and Plug-in Hardware Motor Mounted Mechanism GO-135S UL Listed Voltage Vac 50/60 Hz Vdc Breaker Type - 1203 2404,5 - - 120 2404,5 - - 120 2404,5 - - 120 2404,5 120 2404 - - 120 2404 - - 120 2404 - - 120 2404 - - TEB,1 TEC, TED,1 THED, TB1, THLC12 TFC, TFJ, TFK, THFK TJC, TJJ, TJD, TJK, THJK, TB4, TBC4 TKC, TKM, THKM, TB6, TB8, TBC6, TBC8 SE150 SF250 SG600 SK1200 24 - - 24 48 125 250 24 48 125 250 24 48 125 250 125 - 24 48 125 - 24 48 125 250 24 48 125 250 24 48 Product Number List Price TEDMOMA8 TEDMOMA1 TEDMOMA2 TFKMOMA8 TFKMOMA9 TFKMOMA1 TFKMOMA2 TJKMOMA8 TJKMOMA9 TJKMOMA1 TJKMOMA2 TKMMOMA8 TKMMOMA9 TKMMOMA1 TKMMOMA2 SEMOM1 SEMOM2 SEMOM8 SEMOM9 SFMOM1 SFMOM2 SFMOM8 SFMOM9 SGMOM1 SGMOM2 SGMOM8 SGMOM9 SKMOM1 SKMOM2 SKMOM8 SKMOM9 $1572.006 $710.006 $710.006 $1692.006 $1692.006 $1692.006 $1692.006 $2160.006 $2160.006 $2160.006 $2160.006 $2340.006 $2340.006 $2340.006 $2340.006 $710.00 $710.00 $710.00 $710.00 $1692.00 $1692.00 $1692.00 $1692.00 $2160.00 $2160.00 $2160.00 $2160.00 $2340.00 $2340.00 $2340.00 $2340.00 For TJ4V, TJL, TKL, TK4V ONLY 7 MOLDED CASE CIRCUIT BREAKERS Breaker Type 3 TJ4V, TJL TKL, TK4V Volts 120 Vac 125 Vdc 240 Vac4,5 250 Vdc 24 Vdc 48 Vdc 120 Vac 125 Vdc 240 Vac4,5 250 Vdc 24 Vdc 48 V 343L564G7 343L564G1 343L564G2 SGMSKMOM 343L564G3 - - - Motor Operated Mechanism on SF-Frame breaker GEH-5613 GEH-5613 GEH-5657 GEH-5614 GO-135B Mounting Plate Product Number List Price TJKMOMA1 286A7558G8 $2160.00 TJKMOMA2 286A7558G8 $2160.00 TJKMOMA8 TJKMOMA9 286A7558G8 286A7558G8 $2160.00 $2160.00 TKMMOMA1 286A7558G7 $2340.00 TKMMOMA2 286A7558G7 $2340.00 TKMMOMA8 TKMMOMA9 286A7558G7 286A7558G7 $2340.00 $2340.00 Mounting Screw Kit Product Number TED, TB1 TFJ, TFK TJJ, TJK, TB4 SG600 TKM, TB6, TB8, SK 1For use on 3-pole breaker only. - Mechanism Product Number Mounting Screw Kit for Motor-Operated Mechanism 8 Breaker Type Installation Instructions GO-148B Mounting Screw Kit for TDR Integral Handle List Price $33.506 $8.706 $87.00 $87.009 $121.00 Breaker Type TFC,TFJ,TFK TEC,TED,TB1-B, TJC, TJJ, TJK, TB4, TBC, TKC, TKM, TB6, TB8, TBC6, TBC8 GO-135B Mounting Screw Kit Product Number List Price 343L564G4 $8.60 No Special Mounting Screw Required 2Motor-operated mechanisms must have Code Date 506 + or later for use with THLC1. 3TEDMOMA1 not rated at 50 hertz. 4Suitable for use at 208 Vac. 5Not UL listed. 6GO-135B. 7Requires mounting plate which is supplied at no charge when ordered with mechanism. Order both items. 8Required with plug-in mounting base assembly when used with motor-operating mechanisms or TDR integral-handle kits. Furnished no charge when ordered with mounting base. 9GO-135S. 3-98 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers External Accessories Mechanical Interlocks and Locking Devices Standard Padlocking Devices10 Mechanical Interlocks Walking Beam Type Externally Mounted--UL Component Recognized E-150, TB1 F225 TJJ, TJK, TJ4V, THJ4V, TB4 TKM, TK4V, TB6, TB8 Panel Thickness in Inches .25-1.0 .25-1.0 0.38 1.0 .75-1.0 TEDMI TFKMI TJKMIB TJKMIE TKMMI List Price GO-135B $341.00 $341.00 $341.00 $341.00 $341.001 These face-mounted interlocks prevent two adjacent breakers from being in the ON position at the same time. Spectra RMS Breaker Type SE150, SF250 SG600 SK1200 Face-mounted Interlock Product Number SEFFMI SGFMI SKFMI List Price GO-135S Adapter Kit Required when using handle operator (TDM) or motor operator. Order separately. $341.00 $683.00 $683.00 Breaker Type TQB, TQC, TQL TQB, TQC, TQL TQL TEY E150 Line F225 Line, THLC2, 4 SE150, SF250 SK1200 Device $33.50 $42.00 $59.50 GO-135B Product Number THL103 TQHT1 THT104 TEYLD1 TLD3 $6.504 $2.304 $2.304 $5.00 $5.00 Handle locking TFKLD1 $6.00 SBD1 SKHDLEXT Q Line, TEY Mounting Accessories Description Back Mounting plates Screw Type THQC Breaker held to Mounting Plate by screw clip Snap In THQC, THQC-GF snaps in to spring retaining clip Breaker Type 1-pole THQC 2-pole THQC 3-pole THQC 10-pole THQC 1-pole 2-pole 3-pole 10-pole Bolt-on Base for THQB, TEY 3-pole 1-pole THQC 2-pole THQC Front-mounting Plates7 3-pole THQC 10-pole THQC 3-pole Plug-in Mounting Base (70 Amp) 3-pole TQL 2-pole Plug-in Mounting Base (70 Amp) 2-pole TQL 3-pole Plug-in Mounting Base (100 Amp) 3-pole TQL 2-pole Plug-in Mounting Base (100 Amp) 2-pole TQL 1 & 2-pole Pack of 48 Front/Rear Mounting Clips 15-60A THQC Pack of 24 DIN rail clips DIN rail THQC TQPLD1 TQDPLD1 TQDLPDL1 THP100 TEYPLD1 TEFPLD1 TLC1PLD1 TFKPLD1 TLC4PLD1 TJKPLD1 TKMPLD1 SEPLD SGPLD SKPLD Breaker Type Product Number TQD E150 SE150, SF25011 SG600 J600 SK1200 THLC1 THLC2/4 TQDPLD2 TEDPLD2 SEFPLD2 SGPLD2 TJKPLD2 SKPLD2 THLC1PLD2 THLC4PLD2 List Price $4.70 $20.754 $17.754 $6.504 $9.00 $8.00 $17.00 $4.00 $22.00 $8.00 $28.50 $8.705 $15.005 $28.505 GO-135B List Price $32.00 $32.00 $32.005 $48.005 $48.00 $60.005 $48.00 $48.00 List Price Handle locking Snap-on handle tie - trip indicating Snap-on handle tie - solid Handle locking Handle locking Handle locking Handle extension - replacement Device Product Number EUSERC Approved--Factory Installed Only List Price GO-135S SEFFMIAK2 SGFMIAK3 SKFMIAK Handle-Locking, Handle-Extension Devices Breaker Type TQC TQD TQDL TQB, TQL TEY E150, TB1 THLC1 F225 THLC2, THLC4, TLB4 J600 Line K1200 Line SE150, SF250 SG600 SK1200 PowerMark Gold Main Circuit Breaker Kit Description Order appropriate THQL (10 kAIC) or THHQL breakers separately. GO-138M Product Number List Price TQMH000 $10.50 $4.705 $96.505 GO-135B Product Number TQCBMPA1 TQCBMPA2 TQCBMPA3 TQCBMPA10 TQCGFBMPA1 TQCGFBMPA2 TQCGFBMPA3 TQCGFBMPA10 TEY3B TQCFMP1 TQCFMP2 TQCFMP3 TQCFMP10 571B595DDG2 571B595DDG1 565B837G1 565B837G2 THQCFMK MOLDED CASE CIRCUIT BREAKERS Breaker Type Requires Breaker with Special Factory Drilling. Order 2 Breakers per Interlock, Specifying "Drilled for Mech. Interlock" Product Number GO-135B List Price $8.30 $9.80 $12.00 $32.00 $6.106 $7.606 $9.106 $25.006 $31.50 $8.30 $9.80 $12.00 $14.00 $32.008 $23.758 $38.008 $23.758 $48.009 3 THQCDIN $24.009 1GO-144. 2Not suitable with THCH45 handle. 3Compatible with motor operator only. Product Number SGFMI cannot be used with the handle operator. 4GO-137A. 5GO-135S. 6GO-133. 7Not UL listed. 8GO-134A. 9Price is per pack. 10Suitable for circuit breakers used in group mounted panelboard construction only except for J600, K1200, SE150/SF250, SG600 and SK1200 which screw down to face of breaker. 11Field installable. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-99 Prices and data subject to change without notice Molded Case Circuit Breakers External Accessories Breaker Mounting Hardware and Kits Breaker Mounting Screw Kits Spectra RMS Breaker Type Application For use on mounting plates with tapped holes (4 screws and lockwashers) For use on mounting plates with clearance holes (4 screws, lockwashers and nuts) SE150 SF250 SG600 SK1200 SE150 SF250 SG600 SK1200 GO-135S Kit Product Number Screw Size (inches) List Price SEMSK1 SEMSK3 SFGMSK1 SFMSK1 SFGMSK1 SKMSK1 SEMSK2 SEMSK4 SFGMSK2 SFMSK2 SFGMSK2 SKMSK2 10-33x2 7/8 (std.) 8-32x2 7/8 (opt.) 12-24x3 3/4 (std.) 10-32x3 3/4 (opt.) 12-24x3 3/4 5/16-18x1 1/4 10-32x3 (std.) 8-32x3 (opt.) 12-24x4 (std.) 10-32x4 (opt.) 12-24x4 5/16-18x1 3/4 $2.10 $2.10 $6.10 $6.10 $6.10 $8.70 $2.10 $2.10 $6.10 $6.10 $6.10 $8.70 Back-Connected Line and Load Studs Breaker Type Amperes 50 E1504, TB14, THLC14 TFJ4, TFK4, THFK4 J600, TJ4V, TB4, TJL K1200, TB6, TB8 150 225 400 600 1200 50 SE150 150 Breaker Mounting Screw Kits GO-135B SF250 250 Breaker Type Product Number List Price SG600 600 1-pole E150 2- and 3-pole E150 THLC1 F225 THLC2, 4, TLB4 J600 K1200 1-pole TE, E150 2- and 3-pole E150 THLC1 2- and 3-pole TQD/THQD F225 THLC2, 4, TLB4 J600 K1200 343L162G1 SEMSK4 343L162G22 SFGMSK2 343L162G24 343L162G20 SKMSK2 343L162G7 SEMSK3 343L162G23 343L184G18 SFGMSK1 343L162G25 343L162G11 SKMSK1 $0.85 $2.101 $2.10 $6.101 $5.70 $4.50 $8.701 $0.85 $2.101 $2.10 $4.402 $6.101 $5.70 $4.50 $8.701 SK1200 1200 THQB TQBS1 (packaged 24/kit) $6.003 E150 254V644P1 $0.10 (2 req'd per breaker) Application For use on mounting plates with clearance holes MOLDED CASE CIRCUIT BREAKERS For use on mounting plates with tapped holes 24 mounting screws for connecting low tab to panel board Cup washer (for mounting 1-pole breakers) Std Pkg 2 25/32 (short) 4 13/32 (long) 3 13/32 (short) 5 25/32 (long) 2 23/32 (short) 5 31/32 (long) 5 17/32 5 17/32 5 1/2 8 2 25/32 (short) 4 13/32 (long) 3 13/32 (short) 5 25/32 (long) 2 23/32 (short) 5 31/32 (long) 2 13/16 (short) 6 1/16 (long) 5 1/2 8 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 2 2 2 2 Product Number List Price TEF1 TEF2 TEF3 TEF4 TFK1 TFK2 TJK1 TJK2 TKM11 TKM12 TEF1 TEF2 TEF3 TEF4 TFK1 TFK2 SGBCS1 SGBCS2 TKM11 TKM12 $27.00 $27.00 $28.00 $31.50 $38.50 $59.50 $83.50 $119.00 $220.00 $242.00 $27.00 $27.00 $28.00 $31.50 $38.50 $59.50 $119.001 $119.001 $220.00 $242.00 Back-Connected Center Studs for Dual Voltage Applications GO-135B 3-pole only. Order frame and trip unit separately. Not UL listed. Breaker frame can be supplied with center stud connections permitting operation at both voltages with one trip unit rating. At the higher voltage, connection is made at the line and load terminals only and thus the trip unit carries all the load current. At the lower voltage, where current is double, connection is also made through the center studs permitting half the current to bypass the trip unit. At either voltage, full-load current is carried by the breaker contacts. Maximum Frame Ampere Rating 225A 400A 600A 800A 1200A 3 GO-135B Length, Back of Breaker in Inches Trip Unit Maximum Ampere Rating 110 200 300 400 600 Dual Voltage Frame Only Product Number TFK236F000DV TJK436F000DV TJK636F000DV TKM836F000DV TKM3FDV List Price 5 $1244.00 $2364.00 $2576.00 $3095.00 $4064.00 1GO-135S. 2GO148C. 3Price is per screw. Packaged in quantity of 24. Must be ordered in multiples of 24. 4For proper clearance between poles, a short and long stud must be assembled adjacent to each other. 5Price includes center studs, but does not include line and load back-connected studs or trip unit. 3-100 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers External Accessories Lugs and Associated Hardware Breaker with Line and Load Studs Lugs, Line Shields, Covers and Bus Connectors Copper-Aluminum Lugs Copper Only Lugs With Follower and Extra Plating GO-135B Wire Size For Use With #14-6 Cu, #12-2 Al #4-1/0 Cu-Al #1-300 kcmil Cu-Al #14-8 #14-3 Cu, #12-1 Al #6-2/0 Cu, #4-2/0 Al #3-3/0 Cu, #1-3/0 Al #4-300kcmil Cu-Al #4-300kcmil Cu-Al (1) 6-600kcmil or (2) 2/0-250kcmil Cu-Al (2) 4/0-350kcmil Cu or (2) 300-500kcmil Al (1) 750 kcmil Cu-Al (1) 3/0-500kcmil or (2)3/0-250kcmil Cu-Al (2) 1/0-250kcmil or (1) #4-600 kcmil Cu-Al (2) 2/0-500 kcmil Cu-Al (3) 3/0-500 kcmil Cu-Al (3) 3/0-500 kcmil Cu-Al (4) 250-350 kcmil Cu or (4) 250-500 kcmil Al (3) 750 kcmil Cu-Al (4) 250-350 kcmil Cu or (4) 250-500 kcmil Al #14-2/0 (1) 6-600 kcmil or (2) 1/0-250 kcmil Cu (2) 250-350 kcmil Cu (1) 1/0-600kcmil or (2) 1/0-250 kcmil Cu (2) 2/0-500 kcmil Cu (3) 3/0-500 kcmil Cu (3) 3/0-500 kcmil Cu (4) 250-400kcmil Cu (4) 250-400kcmil Cu TQC (15-60A) (Non DIN Rail) TQC (70-100A) TQD E150, THLC1, TB1, (15-30A) E150, THLC1, TB1, (15-60A) E150, THLC1, TB1, (70-90A) E150, THLC1, TB1, (100-150A) F225 THLC2 J400, TB4, J600 (Thru 400A), TJD J600 (450-600A) J400, TJD TLB4, THLC4 K1200, TB6 (300-400A) K1200, TB6, (500-600A) K1200 (700-1000A), TB8 TK4V - Load end K1200 (1200A) Line Shield Lug Cover, TKM Breaker (two per breaker) Connector (back strap) Line voltage control wire kit for terminating control wire at breaker lugs TK4V - Load end E150, TB1 (thru 150A) J400, TB4 J600 K1200, TB6 (300-400A) K1200, TB6, (500-600A) K1200 (700-1000A), TB8 TK4V - Load end K1200 (1200A) TK4V - Load end TEB, TEC, TED, THED TFJ, TFK, TFC TJJ, TJK, TJC TC041, TCAL41 Lugs TC061, TCAL61, TCAL81 Lugs, TC081A TC0121; TCAL121 Lugs TH4V, THK9V TKM J600 K1200 Product Number List Price TQAL3 TQAL4 TCAL25 TCAL14 TCAL12 TCAL12A TCAL15 TCAL24 TCAL27 TCAL43 TCAL63 TCAL47 TCLK43 TCAL41 TCAL61 TCAL812 TCAL912 TCAL1214 TCAL122 TCAL1314 TC012 TC043 TC063 TC0415 TC061 TC081A TC091 TC0121 TC0131 TEDLS TFKLS TJKLS 789A448G36 789A448G1 789A448G2 286A8066G1 TKMC1 TJLVK7 SKLVK7 $1.50 $1.50 $8.001 $3.00 $3.00 $3.00 $3.00 $8.00 $10.00 $14.00 $23.00 $26.00 $49.00 $38.00 $40.00 $47.003 $47.003 $76.003 $103.005 $76.003 $6.00 $21.00 $34.00 $38.00 $40.00 $53.003 $53.003 $80.003 $80.003 $5.10 $16.25 $14.25 $35.00 $35.00 $35.00 $33.503 $38.00 $9.00 $12.003 1GO-135F. 2Not suitable for 100 A aluminum conductor. 3GO-135S. 4Suitable for 500 kcmil copper for voltage drop considerations. 5Not UL listed. 6End cover supplied with 800A frame is used as lug cover. 73-pole kit. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-101 Prices and data subject to change without notice MOLDED CASE CIRCUIT BREAKERS Accessory 3 Molded Case Circuit Breakers External Accessories Lugs and Associated Hardware Spectra RMS Lugs, Lug Covers, and Bus Lugs Accessory GO-135S Wire Range (Qty.) Aluminum 15-150 70-250 125-600 125-600 Cu 275-1200 Al 225-1100 300-800 600-1200 $3.00 $8.00 $28.00 $42.00 $103.00 $103.00 $47.00 $76.00 #12-3/0 #8-350 kcmil (2)2/0-500 kcmil or (1)#8-600 kcmil #12-3/0 #8-350 kcmil (2)2/0-500 kcmil or (1)#8-600 kcmil (3)300-750 kcmil (3)300-750 kcmil TCAL124 Single lug (3)3/0-500 kcmil (4)250-3503 kcmil (3)3/0-500 kcmil (4)250-500 kcmil TCAL81 TCAL1253 SE150 - - SE3LCK SF250 - - SF3LCK SG600 - - Single lug Single lug Three lug covers for upper (line) end Three lug covers for upper (line) end 3-pole lug cover for upper (line) or lower (load) end 3-pole lug cover for upper (line) or lower (load) end7 Lug cover for upper (line) or lower (load) end4 Single lug Single lug 2-pole lug kit 3-pole lug kit Single lug Single lug Single lug Single lug with .25 Quick Connect for Control Voltage 3-pole kit 3-pole kit Replacement cover for MicroVersaTrip Plus and MicroVersaTrip PM Cover with access to instantaneous set point Cover with no access to instantaneous set point SG600 Replacement Lug Covers and End Covers TCAL18 TCAL29 TCLK265 TCLK365 SG1LCK SG1BCK SK1200 - - SK1LCK SE150 SF250 #12-3/0 #8-350 kcmil (2)2/0-500 kcmil or (1)#8-600 kcmil (3)250-500 kcmil (4)250-400 kcmil (3)250-750 kcmil - - - - - - - TCO18 TCO19 TCOK265 TCOK365 TCO81A TCO121 TCO124 SE150 SF250 #12-3/0 #8-350 kcmil #12-3/0 #8-350 kcmil TCAL18LV TCAL29LV SG600 SK1200 - - - - SG600 Plated Copper Lugs SK1200 Line voltage control wire kit for terminating control wire at breaker lugs SGLVK SKLVK SPCOV1 SG600 / SK1200 - - SPCOV2 SPCOV3 MOLDED CASE CIRCUIT BREAKERS List Price Single lug Single lug 2-pole lug kit2 3-pole lug kit2 SE150 SF250 SK1200 Clear rating plug cover with provision for wire seal Ampacity Range1 Copper Plated extruded aluminum lugs for terminating copper or aluminum cables Product Number Description For Use With - $5.10 - $9.80 - $21.25 - $37.00 - $33.50 15-150 70-250 125-600 125-600 300-800 600-1200 600-1200 $6.00 $21.25 $42.00 $63.00 $53.00 $80.00 $155.00 15-150 70-250 $6.60 $17.75 - - $9.00 $12.00 - $13.25 - $13.25 - $13.25 Lugs and Lug Covers for J and K Frames with MVT-4 and RMS-9 Trip Units Breaker Type Sensor Rating (Amps) TJ, TJL with RMS-9 or MVT-4 3 TKH, TKL with RMS-9 K with MVT-4 TRIP UNIT 150 200 300 400 500 600 400 600 800 1000 1200 400 600 800 1000 1200 Standard Lugs Cu/Al List Product Number Price GO-135S Optional Lugs Cu Only List Product Number Price Lug Covers5 Product List Number Price End Covers5 Product List Number Price TCAL43 $14.006 TCO43 $21.006 - - - - TCAL63 $23.006 TCO63 $34.006 - - - - TCAL81 $47.00 TCO81A $53.00 286A8066G3 $33.50 286A8066G2 $33.50 TCAL1213 $76.00 TCO121 $80.00 286A8066G1 $33.50 286A8066G2 $33.50 TCAL81-Line3 $47.00 TCO81A-Line $53.00 TCAL91-Load3 286A8066G3 $33.50 286A8066G2 $33.50 $47.00 TCO91-Load $53.00 TCAL121-Line3 $76.00 $76.00 TCO121-Line TCO131-Load $80.00 $80.00 286A8066G1 $33.50 286A8066G2 $33.50 TCAL131-Load3 1Both copper and aluminum cables may not cover full ampacity range. 2With lug cover for line or load end. 3500 kcmil acceptable for voltage drop considerations. 4100kA, 480 Vac (SKPA) uses longer lug cover/arc shield on upper end. Use Product Number SKPSHLD for replacement. May be used on other SK1200 devices. 5Breakers supplied less lugs with end covers. When ordering K-frame breaker and lugs, order appropriate lug covers. 6GO-135B. 7Required for line end bus connection. 3-102 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers External Accessories Neutral Grounds and Sensors Power Distribution Lugs GO-135 Breaker Type Max Amperes Wire Range Product Number List Price SE, TED 125 TCAL19PD3 $50.00 SF SG 250 400 (2) 4-14 or (1) 2/0-4 Cu only (6) 4-14 Cu only (12) 4-14 Cu only TCAL28PD3 TCAL40PD3 $75.00 $88.00 Neutral Current Sensors GO-135S For grounded neutral system ground fault applications Breaker Type J K Ampere Rating Product Number List Price 150 200 300 400 500 600 800 1000 1200 TSRG201 TSRG202 TSRG203 TSRG204 TSRG205 TSRG206 TSKG408 TSKG410 TSKG412 $532.00 $532.00 $532.00 $532.00 $532.00 $532.00 $532.00 $532.00 $532.00 Fungus and Moisture Proofing GO-135B Poles Q Line E150 F225 J600 K1200 TB-1 TB-4 TB-6, 8 List Price List Price List Price List Price List Price List Price List Price List Price 1, 2 and 3 $8.90 $22.25 $28.50 $62.50 $84.00 Power Distribution Lugs $84.00 $216.00 $62.50 $231.00 $295.00 Neutral Current Sensor GO-245B Description Product Number List Price Portable Test Set TVRMS2 $3000.00 Rating Plug Removal Tool MOLDED CASE CIRCUIT BREAKERS Test Set for MicroVersaTrip Plus, MicroVersaTrip PM and MicroVersaTrip RMS-9 Trip Units GO-135S Product Number List Price TRTOOL $12.00 "Naval Use" Molded Case Circuit Breakers The following molded case circuit breaker types are optionally available as UL listed per Standard 489, Supplement SB for naval use: --THQB --THQC --SE150 --SF250 --SG600 --SK1200 3 Contact GE sales office for price and delivery. Special Calibration Contact GE sales office for availability. May void UL listing status. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-103 Prices and data subject to change without notice Molded Case Circuit Breakers External Accessories Plug-in Hardware Each plug-in mounting base assembly includes all mounting hardware, studs, and male or female connectors for attachment to one end of breaker. Studs are of different length so by using proper combinations of PD1 and PD2 units, adequate electrical spacing will be assured between adjacent breakers, i.e., a short-long-short (SLS) unit must be used adjacent to a long-short-long (LSL) unit. Two-pole breakers of the E150 line require an open-long-short (OLS) unit on one end of the breaker and a short-long-open (SLO) on the other since these breakers are built with the normal left pole missing while the mounting bases are built from standard three-pole molded supports. Plug-in Mounting Base with Hardware Product Number TF23PD2 shown Spectra RMS and all other two-pole breakers are basically three-pole devices with the center pole omitted. When these breakers are to be mounted side by side, a short-open-short (SOS) unit must be used on one end and a long-open-long (LOL) on the other. Horizontal studs are normally supplied with the flat surface of studs at right angles to the long axis of the breaker. If vertical studs are desired, substitute "C" for "D" in the product number, e.g., TE13PC1 (vertical) or TE13PD1 (horizontal). The optional mounting plate (TMP1, etc.) accurately locates and supports the pair of line and load plug-in mounting-base assemblies and provides a convenient means to attach the entire unit to a metal structure, and serves as a dead front barrier. New drawings are available for customers who prefer to fabricate their own mounting plates. Plug-in Mounting Base Product Number TK123PD2A shown MOLDED CASE CIRCUIT BREAKERS Plug-In Mounting Base Assembly Ampere Rating Breaker Type 150 E1501 TB1 SE150 225 F225 250 SF250 J400 400 TB4 SG400 3 J600, TJ4V, TJL 600 K1200, TKL, TK4V TB6 SG600 K1200, TK4V, TKL 800 TB8 SK800 1000 K1200, TK4V, TKL SK1200 1200 K1200, TK4V, TKL SK1200 GO-135B Plug-In Mounting Bases - 2 Required Per Breaker Stud Configuration No. Poles PD1 PD2 2 3 3 2 3 2 3 2 3 2 3 3 2 3 2 3 2 3 3 2 3 2 3 3 2 3 3 2 3 3 OLS SLS SLS SOS SLS SOS SLS SOS SLS SOS SLS SLS2 SOS SLS SOS SLS SOS SLS SLS2 SOS SLS SOS SLS SLS SOS SLS SLS SOS SLS SLS SLO LSL LSL LOL LSL LOL LSL LOL LSL LOL LSL LSL2 LOL LSL LOL LSL LOL LSL LSL2 LOL LSL LOL LSL LSL LOL LSL LSL LOL LSL LSL Product Number TE12PD1,2 TE13PD1,2 TE13PD1,2 TF22PD1,2 TF23PD1,2 TF22PD1,2 TF23PD1,2 TJ42PD1A,2A TJ43PD1A,2A TJ42PD1A,2A TJ43PD1A,2A SGPC1, SGPC2 TJ62PD1A,2A TJ63PD1A,2A TK62PD1A,2A TK63PD1A,2A TK62PD1A,2A TK63PD1A,2A SGPC1, SGPC2 TK82PD1A,2A TK83PD1A,2A TK82PD1A,2A TK83PD1A,2A TK83PD1A,2A TK102PD1A,2A TK103PD1A,2A TK103PD1A,2A TK122PD1A,2A TK123PD1A,2A TK123PD1A,2A List Price Optional Mounting Base Product Number List Price $250.00 $375.00 $375.00 $300.00 $450.00 $300.00 $450.00 $400.00 $600.00 $400.00 $600.00 $600.003 $500.00 $750.00 $500.00 $750.00 $500.00 $750.00 $600.003 $600.00 $900.00 $600.00 $900.00 $900.00 $700.00 $1050.00 $1050.00 $800.00 $1200.00 $1200.00 TMP1 TMP5 TMP1 TMP2 TMP2 TMP2 TMP2 TMP3 TMP3 TMP6 TMP6 SMP3 TMP3 TMP3 TMP4 TMP4 TMP7 TMP7 SMP3 TMP4 TMP4 TMP7 TMP7 TMP4 TMP4 TMP4 TMP4 TMP4 TMP4 TMP4 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $50.00 $50.00 $40.003 $40.00 $40.00 $50.00 $50.00 $50.00 $50.00 $40.003 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 1Order 3-pole base for use with 2-pole Hi Break and 600 Vac breakers. 2Vertical studs only for SG600 frame. 3GO-135S. 3-104 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers External Accessories R-Frame Ground Fault Neutral Sensors GO-245B Current Sensor Rating Neutral Sensor Product Number 1000A 1600A 2000A List Price TSVG810A TSVG816A TSVG820A $266.00 $266.00 $266.00 1600A Power Break with TPLUGA16 Adapter and 6 TPLUG108 Lugs T-Studs GO-145A Studs mount to breaker or adapter kit. Studs may be rotated for either vertical or horizontal bus. Product number includes 1 stud. Maximum Breaker Ampacity Product Number 1600A 2000A List Price TP16FCA TP20FCA $113.00 $113.00 Type TP16FCA T-Stud Lug Kits GO-245B Kits accept Cu/Al wire and are suitable for direct mounting to breaker. Order one kit per line or load pole. TPLUG108 is suitable for use only with the adapter kits described below. Maximum Ampere Rating Product Number Lugs per Kit Maximum Cables per Pole 1000-1600 1600 TPLUG408 TPLUG401 1 1 4 6 Wire Range Cu/Al List Price 500-800 kcmil 250-800 kcmil $39.00 $23.00 Type TPLUG408 Lug Kit Lug Adapter Kits GO-245B Premounts to bus structure allowing cabling or bussing to be completed prior to breaker mounting. Accepts either lugs or crimp type connector terminals. Product number includes adapter and hardware for three-pole line side or three-pole load side connection. Kits include a set of three corresponding T-studs and are suitable for use with from 1 to 6 TPLUG108 lugs per pole or with from 1 to 6 Crimp Lugs (Anderson No. VCEL-075-12H1 or equivalent) per pole. Maximum Breaker Ampacity Product Number List Price 1000/1600 A 2000 A TPLUGA16 TPLUGA20 $389.00 $486.50 Kirk Key Provision (Factory Installation Only) GO-145A Equips the breaker to accept a zero bolt projection Kirk Key device (supplied by customer) to permit sequencing of breaker operations with other key-type devices. The key remains captured in the breaker frame except when the breaker has been locked in the open position. Not compatible with door interlock and padlock device. Number of Locks 1 2 3 4 Product Number TPK01 (Type F) TPK02 (Type M2F) TPK03 (Type M3F) TPK04 (Type M4F) Terminal Block (Factory Installed Only) GO-145A Offers an external means of terminating accessory leads at the breaker. A maximum of 18 terminals can be supplied on each side of the breaker (36 terminals total). For stationary breakers only. Terminal blocks are rated 10 amperes at 600 Vac. Breaker Terminals TRL/TRP R Frame 6 12 18 24 30 36 Factory Installed Product Numbers Breaker Envelope Size (Amps) 1000, 1600 and 20001 TPTB1R,L TPTB2R,L TPTB3R,L TPTB4L TPTB5L TPTB6L List Price $158.00 $221.00 $286.00 $444.00 $508.00 $573.00 1Limited to left side only. Walking Beam Interlock--Not UL listed GO-145A Product Number List Price TPWB $525.00 List Price $817.00 $817.00 $817.00 $817.00 Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-105 Prices and data subject to change without notice MOLDED CASE CIRCUIT BREAKERS Circuit Breaker Frame Size 3 Molded Case Circuit Breakers Power Management System Accessories Spectra RMS Circuit Breakers with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units All Devices UL Listed for Factory or Field Installation (UL File No. E-57253) Required Accessories Type MicroVersaTrip Plus Trip Unit Accessories Standard Ground Fault Option with 3-phase, 4-wire or 1-phase, 3-wire service Control Power Option Standard or with Protective Relaying MicroVersaTrip PM Trip Unit Ground Fault Option with 3-phase, 4-wire or 1-phase, 3-wire service - Neutral Current Sensor and Terminal Block or Neutral Current Sensor and Junction Box Power Supply Plate or Voltage Module1 or Power Supply Assembly2 Power Supply Plate and Voltage Conditioner Plate or Voltage Module1 or Power Supply Assembly2 and Voltage Conditioner Assembly2 Junction Box, Cable Harness and Auxiliary Switch Neutral Current Sensor 1For installation into GE Spectra Series Switchboards only. 2Requires fuse protection and other components; refer to accessory detail for additional information. Power Supply Plate GO-135PM The Power Supply Plate is used to provide +24 Vdc control power to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip PM or MicroVersaTrip Plus trip systems via the Distribution Cable System. The Power Supply Plate includes the Power Supply Assembly (product number SPSAA) as an integral component and also includes fuse protection for AC source input. Supplemental +24 Vdc input terminals are provided for backup control power applications. Five versions are available. Not suitable for 400 Hz. Description Voltage Rating The Power Supply Plate is rated 24 watts (+24 Vdc at 1.0 amperes) and has the maximum capacity to power a distribution Cable System consisting of 20 breakers and has a maximum system cable length of 40 feet. 120 Vac 208 Vac 240 Vac 480 Vac 600 Vac Product Number List Price SPSA120 SPSA208 SPSA240 SPSA480 SPSA600 $1215.00 $1215.00 $1215.00 $1215.00 $1215.00 Voltage Conditoner Plate Power Supply Plate GO-135PM MOLDED CASE CIRCUIT BREAKERS The Voltage Conditioner Plate is used to provide voltage sensing signals to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip PM Trip Units via the Distribution Cable System. The Voltage Conditioner Plate includes the Voltage Conditioner Assembly (product number SVCAA) as an integral component and also includes fuse protection for the AC source input terminals and three 1-VA high accuracy potential transformers. The Voltage Conditioner Plate requires a control power source of +24 Vdc to operate properly (the Power Supply Assembly or Power Supply Plate can provide this required input). The unit also requires AC direct voltage inputs from the AC source. A GE POWER LEADER network (commnet) connection is provided. Seven versions are available. Not suitable for 400 Hz. 3 Voltage Rating and Service Type Comments Product Number List Price 120 Vac Wye system 208 Vac Wye system 240 Vac Delta system 277 Vac Wye system 480 Vac Wye system 480 Vac Delta system 600 Vac Delta system Phase to Neutral potential Phase to Phase potential Phase to Phase potential Phase to Neutral potential Phase to Phase potential Phase to Phase potential Phase to Phase potential SVCA120Y SVCA208Y SVCA240D SVCA277Y SVCA480Y SVCA480D SVCA600D $1000.00 $1000.00 $1000.00 $1000.00 $1000.00 $1000.00 $1000.00 Voltage Conditioner Plate Note: The Voltage Conditoner Plate has the maximum capacity to power a Distribution Cable System consisting of 20 breakers and has a maximum system cable length of 40 feet. Distribution Cable Junction Box GO-135PM The Distribution Cable Junction Box is a modular connector used to provide quick, easy and reliable attachment of Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip Plus trip systems or MicroVersaTrip PM trip systems to the Distribution Cable System. The Junction Box contains two Distribution Cable Harness plugs, one breaker plug and a terminal block for the connection of a neutral current sensor and an auxiliary switch. Product number SDCJBA is for general purpose OEM applications. Product number SDCJBB is designed for mounting in Spectra Series Panelboards. Description Product Number List Price Distribution Cable Junction Box Distribution Cable Junction Box SDCJBA SDCJBB $155.00 $155.00 Distribution Cable Junction Box Distribution Cable Harness3 GO-135PM The Distribution Cable Harness is a modular connector used to carry electronic signals and/or control power between Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip Plus or MicroVersaTrip PM Trip Units and Distribution Cable accessories. The harnesses come in three lengths. Description Harness Length Product Number List Price Distribution Cable Harness Distribution Cable Harness Distribution Cable Harness 11 inches 30 inches 60 inches SDCHA11 SDCHA30 SDCHA60 $70.00 $80.00 $100.00 3Cannot be connected together. Use 30 inch Distribution Cable Extension (SDCEA30) to extend. 3-106 Prices and data subject to change without notice BuyLog Catalog Distribution Cable Harness www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Power Management System Accessories Spectra RMS Circuit Breakers with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units All Devices UL Listed for Factory or Field Installation (UL File No. E-57253) Required Accessories Type Accessories Standard Ground Fault Option with 3-phase, 4-wire or 1-phase, 3-wire service Control Power Option MicroVersaTrip Plus Trip Unit - Neutral Current Sensor and Terminal Block or Neutral Current Sensor and Junction Box Power Supply Plate or Voltage Module1 or Power Supply Assembly2 Power Supply Plate and Voltage Conditioner Plate or Voltage Module1 or Power Supply Assembly2 and Voltage Conditioner Assembly2 Junction Box, Cable Harness and Auxiliary Switch Neutral Current Sensor Standard or with Protective Relaying MicroVersaTrip PM Trip Unit Ground Fault Option with 3-phase, 4-wire or 1-phase, 3-wire service 1For installation into GE Spectra Series Switchboards only. 2Requires fuse protection and other components; refer to accessory detail for additional information. Distribution Cable Extension GO-135PM The Distribution Cable Extension is used to provide modular expansion of the Distribution Cable System. Description Harness Length Product Number List Price Distribution Cable Extension 30 inches SDCEA30 $80.00 Distribution Cable Terminal Block GO-135PM The Distribution Cable Terminal Block is a modular attachment primarily used to provide an alternate means of input to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip Plus or MicroVersaTrip PM Trip Units. The Terminal Block plugs into the breaker distribution cable receptacle allowing the direct connection of breaker signals via screw terminals. This allows point-to-point wiring of breakers instead of using the Distribution Cable System. Description Product Number List Price Distribution Cable Terminal Block SDCTBA11 $110.00 GO-135PM The Power Supply Assembly is used to provide +24 Vdc Control Power to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip Plus or MicroVersaTrip PM trip systems via the Distribution Cable System. The assembly requires a minimum input voltage of 85 Vac to operate properly (the maximum voltage rating is 240 Vac). Supplemental +24 Vdc input terminals are provided for backup control power applications. The input must be fused with 1/2 ampere class CC fuses (not included). Not suitable for 400 Hz. Description Voltage Rating The Power Supply Assembly is rated 24 watts (+24 Vdc @ 1.0 ampere) and has the maximum capacity to power a Distribution Cable System consisting of 20 breakers and has a maximum system cable length of 40 feet. 85 - 240 Vac Product Number SPSAA Distribution Cable Terminal Block List Price $1000.00 Voltage Conditioner Assembly 3 GO-135PM The Voltage Conditioner Assembly is used to provide voltage sensing signals to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip PM Trip Units via the Distribution Cable System. The Voltage Conditioner Assembly requires a control power source of +24 Vdc to operate properly (the Power Supply Assembly or Power Supply Plate can provide this required input). The unit also requires 120 Vac voltage inputs from the secondary of three 1VA high accuracy potential transformers (not included). The primary side of the potential transformers must be fused with three, 1/2 ampere class CC fuses (not included). A GE POWER LEADER network (commnet) connection is provided. Not suitable for 400 Hz. Description Voltage Rating Requires 120 Vac voltage inputs from the secondary of three 1.0 VA high accuracy potential transformers 120 Vac Product Number SVCAA Power Supply Assembly List Price $680.00 Note: the Voltage Conditioner Assembly has the maximum capacity to power a Distribution Cable System consisting of 20 breakers and has a maximum system cable length of 40 feet. Voltage Conditioner Assembly Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog MOLDED CASE CIRCUIT BREAKERS Power Supply Assembly Distribution Cable Extension 3-107 Prices and data subject to change without notice Molded Case Circuit Breakers Power Management System Accessories Spectra RMS Circuit Breakers with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units All Devices UL Listed for Factory or Field Installation (UL File No. E-57253) Voltage Modules GO-135PM The Voltage Module is used primarily as a Spectra Series Switchboard component to provide +24 Vdc Control Power to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip Plus or MicroVersaTrip PM Trip Units via the Distribution Cable System. The Module also provides voltage sensing signals to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip PM Trip Units on the same Distribution Cable System. The Module contains both a Power Supply Plate and a Voltage Conditioner as integral components. It also includes fuse protection for the AC source input terminals (the modules pressure connectors which mate with the switchboard interior bus bars). A GE POWER LEADER Network (commnet) connection is provided as well as supplemental 24 Vdc input terminals for backup control power applications. Seven versions are available. Not suitable for 400 Hz. Voltage Rating and Service Type Comments Product Number List Price 120 Vac Wye system 208 Vac Wye system 240 Vac Delta system 277 Vac Wye system 480 Vac Wye system 480 Vac Delta system 600 Vac Delta system Phase to Neutral potential Phase to Phase potential Phase to Phase potential Phase to Neutral potential Phase to Phase potential Phase to Phase potential Phase to Phase potential ADSVMA120Y ADSVMA208Y ADSVMA240D ADSVMA277Y ADSVMA480Y ADSVMA480D ADSVMA600D $2350.00 $2350.00 $2350.00 $2350.00 $2350.00 $2350.00 $2350.00 MOLDED CASE CIRCUIT BREAKERS Note: The Voltage Module has the maximum capacity to power a Distribution Cable System consisting of 20 breakers and has a maximum system cable length of 40 feet. Voltage Module Exterior View Voltage Module Interior View 3 3-108 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04 Molded Case Circuit Breakers Accessories-Other Spectra RMS Circuit Breakers with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units All Devices UL Listed for Factory or Field Installation Except Where Noted Neutral Current Sensor GO-135S The neutral current sensor is used in conjunction with breakers that have a MicroVersaTrip Plus or MicroVersaTrip PM Trip Unit with the optional ground fault function and the breaker is connected to a grounded neutral service (3-phase, 4-wire or 1-phase, 3-wire). The neutral current sensor provides an input signal to the breaker trip unit. Breakers connected to a service without a neutral (3-phase, 3-wire) require no external connection or shorting of the breaker cable connector for ground fault to function properly. Breaker Type Sensor Rating (S) Product Number List Price SG SG SG SK SK 150 400 600 800 1200 TSRG201 TSRG204 TSRG206 TSKG408 TSKG412 $532.00 $532.00 $532.00 $532.00 $532.00 MicroVersaTrip Rating Plug Removal Tool GO-135S Product Number List Price TRTOOL $12.00 MicroVersaTrip Portable Power Pack GO-245A Description Product Number List Price Portable Power Pack TVPBP $75.00 MicroVersaTrip Portable Test Set MOLDED CASE CIRCUIT BREAKERS The hand-held MicroVersaTrip portable battery pack provides an independent power source for MicroVersaTrip Plus and MicroVersaTrip PM trip units as an alternative to the TVRMS test set. The power pack is used to power up the trip unit to set or adjust trip set points when the breaker is on the bench or otherwise not powered up. It connects to the trip unit through the rating plug test jack. It requires three standard 9 Vdc alkaline batteries (not included). GO-245A The portable, battery-powered test kit provides for RMS-9, Plus, or PM trip unit self-tests and functional trip/no trip tests. It also provides defeat of the ground fault function and can be used in conjunction with high current test equipment. Interface is via a plug on the front of the trip unit and tests can be conducted with breaker in service. Kit uses six rechargeable ni-cad or standard alkaline "D" cells supplied by customer. Kit can also be powered by 120 Vac source. Description Product Number List Price Portable Test Set2 TVRMS2 $3000.00 3 2May also be used to temporarily defeat ground fault function when using primary injection (high current test set). Note: This test kit is for use with MicroVersaTrip RMS-9, Plus, or PM Trip Units only. Not for use with MicroVersaTrip 4- or 9-Function Trip Units. Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 www.geindustrial.com BuyLog Catalog 3-109 Prices and data subject to change without notice Molded Case Circuit Breakers MOLDED CASE CIRCUIT BREAKERS NOTES: 3 3-110 Prices and data subject to change without notice BuyLog Catalog www.geindustrial.com Rev. 12/04