H3CR-FH3CR-F
10
Connections
Part number Input terminal number Power supply terminal numbers Output terminal numbers
COM Reset AC (common), DC−AC (hot), DC+ COM NC NO
H3CR-F8
H3CR-F8N
H3CR-F8-300
H3CR-F8N-300
— — 2 7 1
8
4
5
3
6
H3CR-F
H3CR-FN
H3CR-F-300
H3CR-FN-300
——2 10 1
11
4
8
3
9
Installation
JINPUT CONNECTIONS
The neutral or common of the power supply is connected to
terminal 2. Terminal 7 of H3CR-F 8-pin terminals and
terminal 10 of H3CR-F 11-pin terminals should be connected
to the “hot” or positive of the power supply.
JOUTPUT CONNECTIONS
Design your control circuit using the relay contacts to switch
the load.
Note: Never switch a load with the contact that is being
used as an input signal. The timer’s circuitry may be
damaged.
JSELECTING TIME RANGES
A time range (0 to 1.2, 0 to 3, 0 to 12, or 0 to 30) is selected
for ON- and OFF-time using the time range selector at the
lower left corner of the front panel, and the selected time
range appears within the plastic frame of the time setting
knob (= scale range display windows).
For ON-time, the desired time unit (sec, 10 s, min, and hrs,
or 10 s, 10 min, hrs, and 10 h) is indicated in the ON-time
unit display window at the lower right corner of the front
panel and can be changed by turning the ON-time unit
selector located below the ON-time unit display window.
For OFF-time, the desired time unit (sec, 10 s, min, and hrs,
or 10 s, 10 min, hrs, and 10 h) is indicated in the OFF-time
unit display window at the upper right corner of the front
panel and can be changed by turning the OFF-time unit
selector located below the OFF-time unit display window.
Time range
selector
ON time unit
selector
OFF time unit
selector
JTRACK MOUNTING
Using P2CF-j
jj
jj
jj
jSocket
Mounting
The P2CF-VV socket has two hooks that secure the
time to the socket. Be sure to allow at least 20 mm (0.79
in) clearance above and below the socket to gain access
to release the hooks for servicing and maintenance. Then
clip rear of the socket to the track. Push the bottom onto
the track until the latch hooks securely.
Removal
Pull the latch on the socket with a flat-blade screwdriver and
remove the timer and socket as one unit.
Hook 20 mm
(0.79 in)
P2CF-11
or P2CF-08
socket
Using Y92F-73 and Y92F-74 Adapters
Install the H3CR-H timer, face first, into the back side of the
Y92F-73 or Y92F-74 adapter so the bezel fits snuggly. Be sure
the retaining clips at the back of the adapter fit into the slots on
either side of the timer. Compress the top and bottom tabs of the
adapter then push the adapter through the front side of the panel
cutout. Be sure the tabs extend after the installation for a
secure fit.
To remove the timer from the adapter, unclip the two retaining
clips at the back of the adapter. To remove the adapter and timer
from the panel as a unit, compress the tabs behind the panel and
push the unit out the front of the panel.
Installation
Panel
Retaining
clips
for timer
Mounting
tabs
Removal
Mounting