R
1
Solid-State Repeat-Cycle Timer H3CR-F
1/16 DIN Solid-State Repeat-Cycle
Timer
Wide power supply ranges of 100 to
240 VAC 24 VAC/VDC, 12VDC
Combinations of independent long or
short ON/OFF time settings are
possible
Fourteen time ranges from 0.05 s to
30hor1.2sto300h
Repeat cycle models with either ON
start or OFF start operating functions
Easy sequence checks through
instantaneous outputs for a zero set
value at any time range
11-pin and 8-pin models are available
Ordering Information
Part number Repeat cycle OFF start H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300
Repeat cycle ON start H3CR-FN H3CR-F8N H3CR-FN-300 H3CR-F8N-300
Timing units 0.05 s to 30 h 1.2 s to 300 h
Terminal form 11-pin models 8-pin models 11-pin models 8-pin models
Supply voltages 100 to 240 VAC, 24 VAC/DC, 12 VDC
Operating mode Repeat cycle
Note: Specify both the model number and supply voltage when ordering.
Example: H3CR-F 24 VAC/DC
Supply voltage
JMODEL NUMBER LEGEND
H3CR - -
123 4
1. Classification
F: Repeat cycle timers
2. Configuration
None: 11-pin socket
8: 8-pin socket
3. Repeat cycle mode
None: OFF start
N: ON start
4. Specified Type
300: Long time range (1.2 s to 300 h) type
H3CR-FH3CR-F
2
JACCESSORIES
Description Part number
Sockets 11-pin Bottom surface or track mounting, top screw terminals P2CF-11
p
Bottom surface or track mounting, top screw terminals, finger-safe terminal conforms to
VDE0106/P100
P2CF-11-E
Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals P3GA-11
8-pin Bottom surface or track mounting, top screw terminals P2CF-08
p
Bottom surface or track mounting, top screw terminals, finger-safe terminal conforms to
VDE0106/P100
P2CF-08-E
Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals P3G-08
Terminal cover for P3G sockets, conforms to VDE0106/P100 Y92A-486
Panel mounting adapter Fits behind panel, ideal for side-by-side installation. Use P3G_-_ sockets Y92F-30
g
p
Panel-mounting adapter (88 mm x 58 mm x 66 mm) Y92F-73
Panel-mounting adapter (58 mm x 50 mm x 66 mm) Y92F-74
Protective cover Hard plastic cover protects against dust, dirt and water; not for use with panel covers Y92A-48B
NEMA 4 cover Waterproof front cover Y92A-48N
Colored panel covers Light gray (Munsell No. 5Y7/1) to match case Y92P-48GL
p
Medium gray (Munsell No. 5Y5/1) Y92P-48GM
Black (Munsell No. N1.5) Y92P-48GB
Mounting track DIN rail, 50 cm (1.64 ft) length; 7.3 mm thick PFP-50N
g
DIN rail, 1 m (3.28 ft) length; 7.3 mm thick PFP-100N
DIN rail, 1 m (3.28 ft) length; 16 mm thick PFP-100N2
End plate PFP-M
Spacer PFP-S
JRANGE SELECTION
ON indicator (orange)
Lit when the output is ON.
OFF indicator (green)
Lit when the output is OFF.
Scale range display
windows
Time range selector (select one
from 1.2, 3, 12, and 30)
For both ON-time and OFF-time.
OFF-time unit display window
OFF-time unit selector (select one from sec.
10 s, min., and hrs, or from 10 s, 10 min, hrs,
and 10 h)
ON-time setting knob (with orange pointer)
For ON-time setting
OFF-time setting knob (with greenpointer)
For OFF-time setting
ON-time unit display window
ON-time unit selector (select one
from sec. 10 s, min., and hrs, or from
10 s, 10 min, hrs, and 10 h)
0.05sto30hModels
Time Time units
range s (sec) x10s
(10 s)
min h(hrs)
1.2 0.05 to 1.2 1.2to12 0.12 to 1.2
30.3to3 3to30 0.3to3
12 1.2to12 12 to 120 1.2to12
30 3to30 30 to 300 3to30
Note: Instantaneous output is available at any time range. To
obtain instantaneous output, set to below 0.
1.2 s to 300 h Models
Time Time units
range x10s
(10 s)
x10min
(10 min)
h(hrs) x10h
(10 h)
1.2 1.2to12 1.2to12 0.12 to 1.2 1.2to12
33to30 3to30 0.3to3 3to30
12 12 to 120 12 to 120 1.2to12 12 to 120
30 30 to 300 30 to 300 3to30 30 to 300
Note: Instantaneous output is available at any time range. To
obtain instantaneous output, set to below 0.
H3CR-F H3CR-F
3
Specifications
Part number H3CR-F/-F-300 H3CR-F8/-F8-300 H3CR-FN/-FN-300 H3CR-F8N/-F8N-300
Operating mode OFF start ON start
Supply
l
AC 100 to 240 VAC (50/60 Hz)
p
p
y
voltage
(
s
e
e
n
o
t
e
)
AC/DC 24 VAC/DC (50/60 Hz)
(
see no
t
e
)
DC 12 VDC
Operating voltage range 85% to 110% of rated supply voltage, 90% to 110% with 12-VDC models
Power
i
AC 100 to 240 VAC: 10 VA (100 VAC applied)
consumption AC/DC 24 VAC/DC: 2 VA (24 VAC applied)/1 W (24 VDC applied)
DC 12 VDC: 1 W
Start, Reset, Gate inputs ON-impedance: 1 kmax.
ON residual voltage: 1 V max
OFF impedance: 500 kmin.
Control Type DPDT relay
outputs Max. load 5 A at 250 VAC, p.f. = 1
Min. load 10mA at 5 VDC
Repeat accuracy ±0.3% full scale max. (±0.3% full scale max. ±10 ms in ranges of 1.2 and 3 s)
Setting error ±5% full scale max ±0.05 s max.
Resetting system Time-limit operation/time-limit reset or self-reset
Resetting time Minimum power-opening time: 0.1 sec
Indicators Output ON indicator (orange LED), output OFF indicator (green LED)
Materials Plastic case (light gray Munsell 5Y7/1)
Mounting Panel, DIN track, or surface depending on socket selected
Connections 11-pin round socket 8-pin round socket 11-pin round socket 8-pin round socket
Weight Approx. 100 g (4.23 oz.)
Approvals UL, CSA, CE
Ambient Operating -- 1 0 °to 55°C(14°to 131°F) with no icing
temperature Storage -- 2 5 °to 65°C(--13°to 149°F) with no icing
Humidity 35% to 85%
Vibration Mechanical durability 10 to 55 Hz with 0.75-mm single amplitude each in three directions
Malfunction durability 10 to 55 Hz with 0.5-mm single amplitude each in three directions
Shock Mechanical durability 980 m/s2(100G) each in three directions
Malfunction durability 98 m/s2(10G) each in three directions
Variation due to voltage change ±0.5% full scale max. (±0.5% full scale max. ±10 ms in ranges of 1.2 and 3 s)
Variation due to temperature change ±2% full scale max. (±2% full scale max. ±l0 ms in ranges of 1.2 and 3 s)
Service life Mechanical 20 million operations min. (under no load at 1,800 operations/h)
Electrical 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
Insulation resistance 100 Mmin. (at 500 VDC)
Note: A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each
DC model.
H3CR-FH3CR-F
4
Engineering Data
Note: A maximum current of 0.15 A can be switched at 125 VDC (cosf= 1) and
a maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
Load current (A)
30 VDC L/R = 7 ms
250 VAC/30 VDC
(cosf=1)
250 VAC (cosf=0.4)
10,000
5,000
1,000
500
100
Switching operations (x 10 )
3
Operation
JBLOCK DIAGRAMS
ON indicator OFF indicator
Indicator
circuit
Power supply
circuit One-chip microcomputer
Zero setting
detection
circuit
Time range/unit
selectors
ROM RAM Clock
AC (DC) input
Output
circuit
H3CR-F H3CR-F
5
Timing Charts
Power supply
(+)
(~)
(--)
(~)
Power supply
(--)(~) (+)(~)
H3CR-F
H3CR-FN
H3CR-F-300
H3CR-FN-300
H3CR-F8
H3CR-F8N
H3CR-F8-300
H3CR-F8N-300
Note: Leave terminals 5, 6, and 7 open.
Do not use them as relay terminals.
Note: Part numbers with an “N included are Repeat cycle ON start timers. All others are Repeat cycle OFF start timers.
Operating mode Timing chart
Repeat cycle
OFF start
ON
OFF
Power
ON
indicator
Output
NO
OFF
indicator
tON:ONsettime
tOFF:OFFsettime
tOFF tON tOFF tON tOFF tOFF
0.1 s min.
Lit
Not lit
Lit
Not lit
Output
NC
ON
OFF
ON
OFF
Repeat cycle
ON start
tON
tON:ONsettime
tOFF:OFFsettime
Power ON
OFF
ON
indicator
OFF
indicator
tOFF tON tOFF tON tOFF
0.1 s min.
Lit
Not lit
Lit
Not lit
Output
NO
Output
NC
ON
OFF
ON
OFF
H3CR-FH3CR-F
6
Dimensions
JTIMERS
Unit: mm (inch)
H3CR-F
H3CR-FN
H3CR-F-300
H3CR-FN-300
H3CR-F8
H3CR-F8N
H3CR-F8-300
H3CR-F8N-300
0.7
17.4
65.7
R1.3
14 dia.
0.7
17.4
65.7
R1.3
14 dia.
66.6 (2.62)
37 dia
(1.46)
52.3
44.8 x 44.8
(1.76 x 1.76)
48 (1.89)
48
(1.89)
66.6 (2.62)
37 dia
(1.46)
52.3
44.8 x 44.8
(1.76 x 1.76)
48 (1.89)
48
(1.89)
JTRACK MOUNTING
100.7 * 98.4
2.3 *
111.7 * 109.4
2.3 *
11-Pin Models 8-Pin Models
P2CF-11/P2CF-11-E P2CF-08/P2CF-08-E
H3CR-F
H3CR-FN
H3CR-F-300
H3CR-FN-300
H3CR-F8
H3CR-F8N
H3CR-F8-300
H3CR-F8N-300
*These dimensions vary with the kind of DIN track (reference value).
JPANEL MOUNTING
Y92F-30 P3GA-11 Y92F-30 P3G-08
80
17 17
75
H3CR-F
H3CR-FN
H3CR-F-300
H3CR-FN-300
11-Pin Models 8-Pin Models
H3CR-F8
H3CR-F8N
H3CR-F8-300
H3CR-F8N-300
H3CR-F H3CR-F
7
JPANEL-MOUNTING ADAPTERS
Unit: mm (inch)
Y92F-30 Panel Cutout
Note: Adapter installs behind the panel. It is ideal for side by side
installation. Use P3G-11 or P3G-08 sockets.
0.5 R max. 45+0.6
-- 0
45+0.6
-- 0
(N)
Panel
52
(2.05)
58
(2.28)
42 (1.65)
Note: Recommended panel thickness is 1 to 3.2 mm.
48 (1.89)
Y92F-73
Y92F-74
Panel
45+0.15
45+0.15
Panel
43+0.2
45+0.2
50+0.2
-- 0
Panel Cutout
Note: The mounting panel thickness
should be 1 to 3.2 mm.
Adapter mounting hole Two, 4.5 dia.
52 to 53
76+0.265 to 66
R0.5 max.
R0.5 max. 45+0.5
-- 0
55+0.5
-- 0
Note: The mounting panel thickness
should be 1 to 3.2 mm.
88
(3.46)
(1.97)
56 (2.2)
58 (2.28)
68
(2,68)
58
(2.28)
JSOCKETS
Track-Mounting/Front-Connecting Socket
Terminal Arrangement/
Internal Connections
(Top View) Surface Mounting Holes
40+0.2
Two,4.5dia.ortwo,M4
Eight
M3.5 x 7.5 sems
Two 4.5 dia.
holes
70 max.
50 max.
20.3 max.
7.8 34.5
35.4
(1.39)
4
P2CF-08
H3CR-FH3CR-F
8
P2CF-08-E (Finger-Safe Terminal Type)
Conforming to VDE0106/P100
4.5
35.4
21.5 max.
5
7.8
70 max.
50 max.
400.2
Two,
4.5
dia.
holes
3
1.3
20.3
19
Eight
M3.5 X 7.5
sems
P2CF-11 Two, 4.5 dia. mounting holes
40+0.2
Two 4.5 dia.
holes
Eleven
M3.5 x 7.5 sems
70 max.
50 max.
31.2 max.
7.8
34.5
4
35.4
(1.39)
P2CF-08-E (Finger-Safe Terminal Type)
Conforming to VDE0106/P100
4.5
35.4
21.5 max.
5
7.8
70 max.
50 max.
400.2
Two,
4.5
dia.
holes
Eight
M3.5 X 7.5 sems
3
1.3
20.3
19
Back-Mounting Socket
P3GA-11
Terminal Arrangement/
Internal Connections
(Bottom View)
27 dia.
4.9
27 dia.
25.6
4.5
16.3
(0.64)
6.2
17
P3G-08
(0.67)
45
(1.77)
45
(1.77)
45
(1.77)
45
(1.77)
H3CR-F H3CR-F
9
Finger-Safe Terminal Cover for P3G(A)
Y92A-48G
34
27.6
16.5
47.4
48 x 48
47.7
x4.47
Twelve, 6.4 dia. holes
Conforming to VDE0106/P100
JPROTECTIVE COVER
Y92A-48B
50.5
(1.99)
50.5
(1.99)
16 (0.63)
overall depth
The hard plastic protective cover prevents accidental resetting. It also shields the front
panel from dirt and water. The cover is intended for use in areas where unusual service
conditions do not exist. The Y92A-48B cover cannot be used with the Y92P Panel
Covers below.
JMOUNTING TRACK AND ACCESSORIES
PFP-100N/PFP-50N PFP-100N2
4.5
15 25 25 25 25 *
10 10
7.3+0.15
35+0.3 27+0.15
1
4.5
15 25 25 25 25 15
10 10
L
35+0.3 27 24
16
29.2
11.5
1,000 (500)
(see note)
Note: The values shown in parentheses are for the PFP-50N.
15 (5)
(see note)
PFP-M End Plate PFP-S Spacer
50
11.5
M4 x 8
pan head
screw
10
6.2 1.8
135.5 35.3
1.8
1.3
4.8
5
16
12
44.3 34.8
16.5
10
H3CR-FH3CR-F
10
Connections
Part number Input terminal number Power supply terminal numbers Output terminal numbers
COM Reset AC (common), DCAC (hot), DC+ COM NC NO
H3CR-F8
H3CR-F8N
H3CR-F8-300
H3CR-F8N-300
2 7 1
8
4
5
3
6
H3CR-F
H3CR-FN
H3CR-F-300
H3CR-FN-300
——2 10 1
11
4
8
3
9
Installation
JINPUT CONNECTIONS
The neutral or common of the power supply is connected to
terminal 2. Terminal 7 of H3CR-F 8-pin terminals and
terminal 10 of H3CR-F 11-pin terminals should be connected
to the “hot” or positive of the power supply.
JOUTPUT CONNECTIONS
Design your control circuit using the relay contacts to switch
the load.
Note: Never switch a load with the contact that is being
used as an input signal. The timer’s circuitry may be
damaged.
JSELECTING TIME RANGES
A time range (0 to 1.2, 0 to 3, 0 to 12, or 0 to 30) is selected
for ON- and OFF-time using the time range selector at the
lower left corner of the front panel, and the selected time
range appears within the plastic frame of the time setting
knob (= scale range display windows).
For ON-time, the desired time unit (sec, 10 s, min, and hrs,
or 10 s, 10 min, hrs, and 10 h) is indicated in the ON-time
unit display window at the lower right corner of the front
panel and can be changed by turning the ON-time unit
selector located below the ON-time unit display window.
For OFF-time, the desired time unit (sec, 10 s, min, and hrs,
or 10 s, 10 min, hrs, and 10 h) is indicated in the OFF-time
unit display window at the upper right corner of the front
panel and can be changed by turning the OFF-time unit
selector located below the OFF-time unit display window.
Time range
selector
ON time unit
selector
OFF time unit
selector
JTRACK MOUNTING
Using P2CF-j
jj
jj
jj
jSocket
Mounting
The P2CF-VV socket has two hooks that secure the
time to the socket. Be sure to allow at least 20 mm (0.79
in) clearance above and below the socket to gain access
to release the hooks for servicing and maintenance. Then
clip rear of the socket to the track. Push the bottom onto
the track until the latch hooks securely.
Removal
Pull the latch on the socket with a flat-blade screwdriver and
remove the timer and socket as one unit.
Hook 20 mm
(0.79 in)
P2CF-11
or P2CF-08
socket
Using Y92F-73 and Y92F-74 Adapters
Install the H3CR-H timer, face first, into the back side of the
Y92F-73 or Y92F-74 adapter so the bezel fits snuggly. Be sure
the retaining clips at the back of the adapter fit into the slots on
either side of the timer. Compress the top and bottom tabs of the
adapter then push the adapter through the front side of the panel
cutout. Be sure the tabs extend after the installation for a
secure fit.
To remove the timer from the adapter, unclip the two retaining
clips at the back of the adapter. To remove the adapter and timer
from the panel as a unit, compress the tabs behind the panel and
push the unit out the front of the panel.
Installation
Panel
Retaining
clips
for timer
Mounting
tabs
Removal
Mounting
tabs
H3CR-F H3CR-F
Precautions
To avoid malfunction or damage, do not change the time unit or
time range while the timer is in operation. Be sure to turn off the
power supply to the timer before changing any of the selections.
Operating Environment
Do not use the Timer in the following locations.
Locations with radical temperature changes.
Locations with high humidity that may result in condensation.
Locations with excessive vibration or shock.
Locations with corrosive gas or dust.
Locations where the Timer is exposed to sprayed water, oil,
or chemicals.
Organic solvents (such as paint thinner) as well as strong acid or
alkali solutions will damage the outer casing of the Timer.
If the Timer is used in an area with excessive electrical noise, be
sure to separate the Timer, wires, and input device as far as
possible from the noise sources. Furthermore, it is recommended
that the input signal wiring be shielded to prevent electrical
interference.
JPRECAUTIONS FOR EN (VDE)
CONFORMANCE
The H3CR-A Series, installed as a built-in timer, conforms to
EN61812-1 (VDE0435/P2021) provided that the following
conditions are satisfied.
Make sure that no voltage is applied to any terminals before
removing the Timer from the Socket.
The output section of the H3CR-A is provided only with basic
isolation. Provide supplementary basic isolation on the load side
connected to the output so that reinforced isolation required by
the EN (VDE) standards will be ensured.
The H3CR-A Was Designed to Meet the
Following Conditions
Overvoltage category III
Pollution degree 2
Isolation
Operation parts: Reinforced isolation
-- With clearance of 5.5 mm and creepage distance of 5.5
mm at 230 VAC
Output: Basic isolation (See Note.)
-- With clearance of 3 mm and creepage distance of 3 mm at
230 VAC
Note: The 11-pin model ensures basic isolation by itself and also
ensures basic isolation with the 11-pin model mounted to
the OMRON P2CF-11 or P3GA-11 Socket.
Connect the two output contacts different in polarity to the loads,
so that they will be the same in potential.
JVOLTAGE WITHSTAND TEST
If the Timer is mounted to a control board, remove the Timer from
the control board or short-circuit the control board circuitry before
carrying out a voltage withstand test between the electric circuitry
and non-charged metal part of the Timer. This protects the
internal circuitry of the Timer from damage.
C at . N o. G C T MC N 1 3/02 S pec if ic at ions s ubjec t t o c hange w it hout not ic e. P r int ed in U . S . A .
OMRON ELECTRONICS LLC
OneEastCommerceDrive
Schaumburg, IL 60173
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
1-800-55-OMRON
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
416-286-6465
R
OMRON ON--LINE
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci