R H3CR-F Solid-State Repeat-Cycle Timer 1/16 DIN Solid-State Repeat-Cycle Timer Wide power supply ranges of 100 to 240 VAC 24 VAC/VDC, 12VDC Combinations of independent long or short ON/OFF time settings are possible Fourteen time ranges from 0.05 s to 30 h or 1.2 s to 300 h Repeat cycle models with either ON start or OFF start operating functions Easy sequence checks through instantaneous outputs for a zero set value at any time range 11-pin and 8-pin models are available Ordering Information Part number Repeat cycle OFF start H3CR-F H3CR-F8 H3CR-F-300 Repeat cycle ON start H3CR-FN H3CR-F8N H3CR-FN-300 Timing units 0.05 s to 30 h Terminal form 11-pin models Supply voltages 100 to 240 VAC, 24 VAC/DC, 12 VDC Operating mode Repeat cycle Note: 8-pin models 11-pin models Supply voltage J MODEL NUMBER LEGEND 1 2 3 1. Classification F: Repeat cycle timers 2. Configuration None: 11-pin socket 8: 8-pin socket 4 3. Repeat cycle mode None: OFF start N: ON start 4. Specified Type 300: Long time range (1.2 s to 300 h) type 1 H3CR-F8N-300 1.2 s to 300 h Specify both the model number and supply voltage when ordering. Example: H3CR-F 24 VAC/DC H3CR - H3CR-F8-300 8-pin models H3CR-F H3CR-F J ACCESSORIES Description Sockets Part number 11-pin p Bottom surface or track mounting, top screw terminals P2CF-11 Bottom surface or track mounting, top screw terminals, finger-safe terminal conforms to VDE0106/P100 P2CF-11-E Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals P3GA-11 Bottom surface or track mounting, top screw terminals P2CF-08 Bottom surface or track mounting, top screw terminals, finger-safe terminal conforms to VDE0106/P100 P2CF-08-E Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals P3G-08 Terminal cover for P3G sockets, conforms to VDE0106/P100 Y92A-486 Fits behind panel, ideal for side-by-side installation. Use P3G_-_ sockets Y92F-30 Panel-mounting adapter (88 mm x 58 mm x 66 mm) Y92F-73 Panel-mounting adapter (58 mm x 50 mm x 66 mm) Y92F-74 Protective cover Hard plastic cover protects against dust, dirt and water; not for use with panel covers Y92A-48B NEMA 4 cover Waterproof front cover Y92A-48N Colored panel p covers Light gray (Munsell No. 5Y7/1) to match case Y92P-48GL Medium gray (Munsell No. 5Y5/1) Y92P-48GM Black (Munsell No. N1.5) Y92P-48GB DIN rail, 50 cm (1.64 ft) length; 7.3 mm thick PFP-50N DIN rail, 1 m (3.28 ft) length; 7.3 mm thick PFP-100N DIN rail, 1 m (3.28 ft) length; 16 mm thick PFP-100N2 8-pin p Panel mounting g adapter p Mounting g track End plate PFP-M Spacer PFP-S J RANGE SELECTION OFF indicator (green) Lit when the output is OFF. ON indicator (orange) Lit when the output is ON. OFF-time unit display window Scale range display windows ON-time setting knob (with orange pointer) For ON-time setting OFF-time unit selector (select one from sec. 10 s, min., and hrs, or from 10 s, 10 min, hrs, and 10 h) OFF-time setting knob (with green pointer) For OFF-time setting Time range selector (select one from 1.2, 3, 12, and 30) For both ON-time and OFF-time. ON-time unit display window ON-time unit selector (select one from sec. 10 s, min., and hrs, or from 10 s, 10 min, hrs, and 10 h) 0.05 s to 30 h Models Time range Time units 1.2 0.05 to 1.2 1.2 to 12 3 0.3 to 3 12 1.2 to 12 30 3 to 30 Note: s (sec) 1.2 s to 300 h Models Time range Time units 0.12 to 1.2 1.2 1.2 to 12 1.2 to 12 0.12 to 1.2 1.2 to 12 3 to 30 0.3 to 3 3 3 to 30 3 to 30 0.3 to 3 3 to 30 12 to 120 1.2 to 12 12 12 to 120 12 to 120 1.2 to 12 12 to 120 30 to 300 3 to 30 30 30 to 300 30 to 300 3 to 30 30 to 300 x 10 s (10 s) min h (hrs) Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0. Note: 2 x 10 s (10 s) x 10 min (10 min) h (hrs) x 10 h (10 h) Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0. H3CR-F H3CR-F Specifications Part number H3CR-F/-F-300 Operating mode OFF start H3CR-F8/-F8-300 Supply pp y voltage l (see note) AC 100 to 240 VAC (50/60 Hz) AC/DC 24 VAC/DC (50/60 Hz) DC 12 VDC H3CR-FN/-FN-300 H3CR-F8N/-F8N-300 ON start Operating voltage range 85% to 110% of rated supply voltage, 90% to 110% with 12-VDC models Power consumption i AC 100 to 240 VAC: 10 VA (100 VAC applied) AC/DC 24 VAC/DC: 2 VA (24 VAC applied)/1 W (24 VDC applied) DC 12 VDC: 1 W Start, Reset, Gate inputs ON-impedance: 1 k max. ON residual voltage: 1 V max OFF impedance: 500 k min. Control outputs Type DPDT relay Max. load 5 A at 250 VAC, p.f. = 1 Min. load 10mA at 5 VDC Repeat accuracy 0.3% full scale max. (0.3% full scale max. 10 ms in ranges of 1.2 and 3 s) Setting error 5% full scale max 0.05 s max. Resetting system Time-limit operation/time-limit reset or self-reset Resetting time Minimum power-opening time: 0.1 sec Indicators Output ON indicator (orange LED), output OFF indicator (green LED) Materials Plastic case (light gray Munsell 5Y7/1) Mounting Panel, DIN track, or surface depending on socket selected Connections 11-pin round socket Weight Approx. 100 g (4.23 oz.) Approvals Ambient temperature Shock 11-pin round socket 8-pin round socket UL, CSA, CE Operating --10 to 55C (14 to 131F) with no icing Storage --25 to 65C (--13 to 149F) with no icing Humidity Vibration 8-pin round socket 35% to 85% Mechanical durability 10 to 55 Hz with 0.75-mm single amplitude each in three directions Malfunction durability 10 to 55 Hz with 0.5-mm single amplitude each in three directions Mechanical durability 980 m/s2 (100G) each in three directions Malfunction durability 98 m/s2 (10G) each in three directions Variation due to voltage change 0.5% full scale max. (0.5% full scale max. 10 ms in ranges of 1.2 and 3 s) Variation due to temperature change 2% full scale max. (2% full scale max. l0 ms in ranges of 1.2 and 3 s) Service life Mechanical 20 million operations min. (under no load at 1,800 operations/h) Electrical 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) Insulation resistance 100 M min. (at 500 VDC) Note: A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC model. 3 H3CR-F H3CR-F Engineering Data Note: A maximum current of 0.15 A can be switched at 125 VDC (cosf = 1) and a maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 10 mA at 5 VDC (failure level: P). Switching operations (x 103 ) 10,000 5,000 1,000 500 30 VDC L/R = 7 ms 250 VAC/30 VDC (cosf = 1) 100 250 VAC (cosf = 0.4) Load current (A) Operation J BLOCK DIAGRAMS ON indicator Zero setting detection circuit OFF indicator Indicator circuit ROM AC (DC) input Power supply circuit RAM Clock One-chip microcomputer 4 Output circuit Time range/unit selectors H3CR-F H3CR-F Timing Charts H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 H3CR-F8 H3CR-F8N H3CR-F8-300 H3CR-F8N-300 (--) (~) (--)(~) (+) (~) (+)(~) Power supply Power supply Note: Leave terminals 5, 6, and 7 open. Do not use them as relay terminals. Note: Part numbers with an "N" included are Repeat cycle ON start timers. All others are Repeat cycle OFF start timers. Operating mode Timing chart Repeat cycle OFF start 0.1 s min. Power ON OFF tOFF tON tOFF tON tOFF tOFF ON Lit indicator Not lit Lit OFF indicator Not lit Output NO ON OFF Output NC ON OFF tON: ON set time tOFF: OFF set time Repeat cycle ON start 0.1 s min. Power ON OFF ON indicator Lit OFF indicator Lit Output NO ON Output NC ON tON tOFF Not lit Not lit OFF OFF tON: ON set time tOFF: OFF set time 5 tON tOFF tON tOFF H3CR-F H3CR-F Dimensions J TIMERS Unit: mm (inch) H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 17.4 48 (1.89) 5.7 66.6 (2.62) 6 52.3 0.7 44.8 x 44.8 (1.76 x 1.76) 37 dia (1.46) 48 (1.89) 14 dia. R1.3 H3CR-F8 H3CR-F8N H3CR-F8-300 H3CR-F8N-300 17.4 48 (1.89) 5.7 66.6 (2.62) 6 52.3 44.8 x 44.8 (1.76 x 1.76) 37 dia (1.46) 48 (1.89) 14 dia. R1.3 J TRACK MOUNTING 11-Pin Models 8-Pin Models P2CF-11/P2CF-11-E P2CF-08/P2CF-08-E 111.7 * H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 109.4 H3CR-F8 H3CR-F8N H3CR-F8-300 H3CR-F8N-300 100.7 * 2.3 * 98.4 2.3 * * These dimensions vary with the kind of DIN track (reference value). J PANEL MOUNTING 11-Pin Models 17 8-Pin Models 17 80 H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 Y92F-30 75 H3CR-F8 H3CR-F8N H3CR-F8-300 H3CR-F8N-300 P3GA-11 0.7 Y92F-30 6 P3G-08 H3CR-F H3CR-F J PANEL-MOUNTING ADAPTERS Unit: mm (inch) Y92F-30 Panel Cutout Panel 0.5 R max. 58 (2.28) 52 (2.05) 45 +0.6 --0 (N) +0.6 45 --0 42 (1.65) 48 (1.89) Note: Recommended panel thickness is 1 to 3.2 mm. Note: Adapter installs behind the panel. It is ideal for side by side installation. Use P3G-11 or P3G-08 sockets. Y92F-73 Panel Cutout Panel Adapter mounting hole Two, 4.5 dia. R0.5 max. 45+0.15 52 to 53 88 (3.46) 65 to 66 76+0.2 45+0.15 58 (2.28) Note: Y92F-74 Panel 56 (2.2) 58 (2.28) 45+0.2 R0.5 max. 68 (2,68) 43+0.2 45 +0.5 --0 55 +0.5 --0 Note: +0.2 50 --0 (1.97) The mounting panel thickness should be 1 to 3.2 mm. The mounting panel thickness should be 1 to 3.2 mm. J SOCKETS Track-Mounting/Front-Connecting Socket P2CF-08 Eight M3.5 x 7.5 sems 7.8 3 4.5 Terminal Arrangement/ Internal Connections (Top View) Surface Mounting Holes Two, 4.5 dia. or two, M4 70 max. 35.4 (1.39) Two 4.5 dia. holes 4 50 max. 20.3 max. 7 40+0.2 H3CR-F H3CR-F P2CF-08-E (Finger-Safe Terminal Type) Conforming to VDE0106/P100 Eight M3.5 X 7.5 sems 7.8 5 4.5 3 1.3 70 max. 35.4 Two, 4.5 dia. holes 19 40 0.2 20.3 50 max. 21.5 max. P2CF-11 Eleven M3.5 x 7.5 sems 3 7.8 4.5 Two, 4.5 dia. mounting holes 40+0.2 35.4 (1.39) 70 max. Two 4.5 dia. holes 4 50 max. 31.2 max. P2CF-08-E (Finger-Safe Terminal Type) Conforming to VDE0106/P100 Eight M3.5 X 7.5 sems 7.8 5 4.5 3 1.3 70 max. 35.4 Two, 4.5 dia. holes 40 0.2 50 max. 19 20.3 21.5 max. Back-Mounting Socket P3G-08 Terminal Arrangement/ Internal Connections (Bottom View) 27 dia. 45 (1.77) 45 (1.77) P3GA-11 4.9 17 (0.67) 27 dia. 45 (1.77) 25.6 45 (1.77) 4.5 16.3 (0.64) 6.2 8 H3CR-F H3CR-F Finger-Safe Terminal Cover for P3G(A) Conforming to VDE0106/P100 Twelve, 6.4 dia. holes Y92A-48G 47.7 x 4.47 34 48 x 48 16.5 27.6 47.4 J PROTECTIVE COVER Y92A-48B The hard plastic protective cover prevents accidental resetting. It also shields the front panel from dirt and water. The cover is intended for use in areas where unusual service conditions do not exist. The Y92A-48B cover cannot be used with the Y92P Panel Covers below. 50.5 (1.99) 16 (0.63) overall depth 50.5 (1.99) J MOUNTING TRACK AND ACCESSORIES PFP-100N/PFP-50N PFP-100N2 16 7.3+0.15 4.5 4.5 15 Note: 25 10 25 25 1,000 (500) (see note) 10 25 * 35+0.3 27+0.15 35+0.3 15 1 15 (5) (see note) 25 25 10 25 L 27 25 15 10 24 29.2 1 1.5 The values shown in parentheses are for the PFP-50N. PFP-M End Plate PFP-S Spacer 10 6.2 1.8 1 50 1.8 11.5 10 M4 x 8 pan head screw 16 12 5 35.5 35.3 34.8 44.3 1.3 4.8 16.5 9 H3CR-F H3CR-F Connections Part number Input terminal number Power supply terminal numbers Output terminal numbers COM Reset AC (common), DC- AC (hot), DC+ COM NC NO H3CR-F8 H3CR-F8N H3CR-F8-300 H3CR-F8N-300 -- -- 2 7 1 8 4 5 3 6 H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 -- -- 2 10 1 11 4 8 3 9 Installation J INPUT CONNECTIONS J TRACK MOUNTING The neutral or common of the power supply is connected to terminal 2. Terminal 7 of H3CR-F 8-pin terminals and terminal 10 of H3CR-F 11-pin terminals should be connected to the "hot" or positive of the power supply. Using P2CF-j jj Socket Mounting The P2CF-VV socket has two hooks that secure the time to the socket. Be sure to allow at least 20 mm (0.79 in) clearance above and below the socket to gain access to release the hooks for servicing and maintenance. Then clip rear of the socket to the track. Push the bottom onto the track until the latch hooks securely. J OUTPUT CONNECTIONS Design your control circuit using the relay contacts to switch the load. Note: Never switch a load with the contact that is being used as an input signal. The timer's circuitry may be damaged. Hook J SELECTING TIME RANGES A time range (0 to 1.2, 0 to 3, 0 to 12, or 0 to 30) is selected for ON- and OFF-time using the time range selector at the lower left corner of the front panel, and the selected time range appears within the plastic frame of the time setting knob (= scale range display windows). 20 mm (0.79 in) P2CF-11 or P2CF-08 socket Removal Pull the latch on the socket with a flat-blade screwdriver and remove the timer and socket as one unit. For ON-time, the desired time unit (sec, 10 s, min, and hrs, or 10 s, 10 min, hrs, and 10 h) is indicated in the ON-time unit display window at the lower right corner of the front panel and can be changed by turning the ON-time unit selector located below the ON-time unit display window. Using Y92F-73 and Y92F-74 Adapters Install the H3CR-H timer, face first, into the back side of the Y92F-73 or Y92F-74 adapter so the bezel fits snuggly. Be sure the retaining clips at the back of the adapter fit into the slots on either side of the timer. Compress the top and bottom tabs of the adapter then push the adapter through the front side of the panel cutout. Be sure the tabs extend after the installation for a secure fit. For OFF-time, the desired time unit (sec, 10 s, min, and hrs, or 10 s, 10 min, hrs, and 10 h) is indicated in the OFF-time unit display window at the upper right corner of the front panel and can be changed by turning the OFF-time unit selector located below the OFF-time unit display window. To remove the timer from the adapter, unclip the two retaining clips at the back of the adapter. To remove the adapter and timer from the panel as a unit, compress the tabs behind the panel and push the unit out the front of the panel. OFF time unit selector Time range selector ON time unit selector Installation Mounting tabs Removal Panel Retaining clips for timer Mounting tabs 10 H3CR-F H3CR-F Precautions To avoid malfunction or damage, do not change the time unit or time range while the timer is in operation. Be sure to turn off the power supply to the timer before changing any of the selections. Operating Environment Do not use the Timer in the following locations. * * Locations with radical temperature changes. Locations with high humidity that may result in condensation. * * Locations with excessive vibration or shock. Locations with corrosive gas or dust. * Locations where the Timer is exposed to sprayed water, oil, or chemicals. The H3CR-A Was Designed to Meet the Following Conditions * Overvoltage category III * * Pollution degree 2 Isolation Operation parts: Reinforced isolation -- With clearance of 5.5 mm and creepage distance of 5.5 mm at 230 VAC Output: Basic isolation (See Note.) Organic solvents (such as paint thinner) as well as strong acid or alkali solutions will damage the outer casing of the Timer. If the Timer is used in an area with excessive electrical noise, be sure to separate the Timer, wires, and input device as far as possible from the noise sources. Furthermore, it is recommended that the input signal wiring be shielded to prevent electrical interference. J PRECAUTIONS FOR EN (VDE) CONFORMANCE The H3CR-A Series, installed as a built-in timer, conforms to EN61812-1 (VDE0435/P2021) provided that the following conditions are satisfied. -- With clearance of 3 mm and creepage distance of 3 mm at 230 VAC Note: The 11-pin model ensures basic isolation by itself and also ensures basic isolation with the 11-pin model mounted to the OMRON P2CF-11 or P3GA-11 Socket. Connect the two output contacts different in polarity to the loads, so that they will be the same in potential. J VOLTAGE WITHSTAND TEST If the Timer is mounted to a control board, remove the Timer from the control board or short-circuit the control board circuitry before carrying out a voltage withstand test between the electric circuitry and non-charged metal part of the Timer. This protects the internal circuitry of the Timer from damage. Make sure that no voltage is applied to any terminals before removing the Timer from the Socket. The output section of the H3CR-A is provided only with basic isolation. Provide supplementary basic isolation on the load side connected to the output so that reinforced isolation required by the EN (VDE) standards will be ensured. NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. R OMRON ELECTRONICS LLC OMRON ON--LINE OMRON CANADA, INC. 1-800-55-OMRON Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci 416-286-6465 One East Commerce Drive Schaumburg, IL 60173 Cat. No. GC TMCN1 3/02 Specifications subject to change without notice. 885 Milner Avenue Scarborough, Ontario M1B 5V8 Printed in U.S.A.