LW Series Low Profile Triple Output Features u u u u u 26mm height Outputs 2 and 3 isolated from output 1 Universal Input (85 - 265VAC) Low Profile Wattbox design on LWT Key Market Segments & Applications Specifications Model Max Output Power (typ) W Efficiency (Typ) % AC Input Voltage range DC Input Voltage range Input Current Typ (100/200VAC) A Inrush Current (110/200VAC) A Output 1 Voltage Adjustment Output Voltage Accuracy Temperature Coefficient Line Regulation Load Regulation Ripple & Noise Overcurrent Protection Overvoltage Protection V Hold Up Time (Typ at 100VAC) ms Series Operation Operating Temperature Storage Temperature C Operating Humidity Storage Humidity Cooling Withstand Voltage Isolation Resistance Vibration (non operating) Shock Safety Agency Approvals Conducted EMI Weight (Typ) g Size (WxHxD) mm Warranty - LWT15H 17 72 LWT30H LWT50H 30 50 73 72 85 - 265VAC (47 - 440Hz) 110 - 350VDC 110 - 330VDC 0.4/0.22 0.7/0.42 1.2/0/7 14/28 16/32 16/32 5V: 5 to 5.25V, 12V: 12 to 12.6V, 15V: 15V to 15.75V Output 2 & 3 5% Output 1 < 1%, Output 2 or 3, <2% at 0 - 60C 1% 2% Output 1: 100mV, Outputs 2 & 3: 150mV >105% Main output only: 5.75 - 6.75V, manual reset 20 Possible LWT: 0C to +60C, derate as follows: 40C: 100%, 50C: 80%, 60C: 60% -30 to +85C 30 - 90% RH (Non condensing) 10 - 95% RH (Non condensing) Convection Input to Gnd 2kVAC Input to Output 3kVAC (20mA) >100M at 25C & 70%RH, Output to Ground 500VDC 10-55Hz(1 min) <19.6m/s2 (1 hr) 196.1m/s2 UL60950-1, CSA60950-1, EN60950-1, CE LVD VDE Class B, FCC Class B 220 300 400 Please refer to outline drawings One Year Note: See Installation Manual for full details, test methods of parameters and application notes 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 92 Disclaimer: us.tdk-lambda.com/lp/legal.htm LW Series Options Model LW Outline Drawing Output Voltage Min Current Max Current V1 V2 V3 V1 V2 V3 V1 V2 V3 V1 V2 V3 V1 V2 V3 V1 V2 V3 V1 V2 V3 V1 V2 V3 V1 V2 V3 5V +12V -12V 5V +15V -15V 5V +12V -5V 5V +12V -12V 5V +15V -15V 5V +12V -5V 5V +12V -12V 5V +15V -15V 5V +12V -5V 0.5 0.0 0.0 0.5 0.0 0.0 0.5 0.0 0.0 0.7 0.0 0.0 0.7 0.0 0.0 0.7 0.0 0.0 1.0 0.0 0.0 1.0 0.0 0.0 1.0 0.0 0.0 3.0 0.6 0.4 3.0 0.6 0.4 3.0 0.6 0.4 5.0 1.2 0.6 5.0 1.2 0.6 5.0 1.2 0.6 8.0 1.5 1.0 8.0 1.5 1.0 8.0 1.5 1.0 A E D LWT15H-522 LWT15H-5FF LWT15H-525 LWT30H-522 LWT30H-5FF LWT30H-525 LWT50H-522 LWT50H-5FF LWT50H-525 G C F COMPONENT SIDE TOP VIEW B CN1 M USE 2x 3M SCREWS 4MM MAX PROTRUSION INTO UNIT CN2 USE 2x 3M SCREWS 4MM MAX PROTRUSION INTO UNIT L BOTTOM VIEW K H J DIMENSIONS: MODEL A WEIGHT: B C D E .15 (3.8) 1.811 (46.0) .433 (11.0) 1.02 (26.0) .47 (12.0) .98 (25.0) .98 (25.0) 1.77 (45.0) 3.937 (99.9) .314 (8.0) 1.02 (26.0) .35 (8.8) 1.02 (26.0) .39 (10.0) 4.625 (117.5) .433 (11.0) - LWT-15 5.03 (128.0) .31 (7.9) LWT-30 6.29 (160.0) LWT-50 6.29 (159.7) F G H K L M .15 (3.8) 1.988 (50.5) .905 (23.0) .21 (5.5) 1.69 (43.0) 2.36 (59.9) 2.75 (70.0) 3.228 (82.0) .31 (7.8) 3.82 (97.0) J 3.897 (99.0) 5.433 .66 (17.0) (138.0) 3.602 1.67 (42.4) (91.5) MODEL LBS LWT-15 .50 LWT-30 .70 LWT-50 1.00 1. DIMENSIONS ARE IN INCHES EXCEPT DIMENSIONS IN ( ) ARE IN MM. 2. 4x M3 TAPPED HOLES FOR CUSTOMER MTG. SCREWS MUST NOT PROTRUDE INTO P.S. BY MORE THAN .15 ( 4 ) MAX. Other Industrial Products HWS ZWQ ZP LS MTW 15W-1500W Single output 80W-170W Quad output 20W-60W Single, dual & triple output 25W-150W Single output, low cost 15W-60W Triple output For Additional Information, please visit us.tdk-lambda.com/lp/products/lw-series.htm 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 93 Revision B2: Oct 2012 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TDK-Lambda: LWT-15H-522 LWT-15H-525 LWT-30H-522 LWT-50H-522 LWT-50H-525 LWT-50H-5FF LWT-30H-525