1© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard LF0039_SSHB21HS 3/4/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
One world. One KEMET
Benets
Proprietary 5HT and 10HZ ferrite materials and equivalents
Optimization of magnetic circuit and material
One coil to suppress both common and normal noise
High impedance in wide frequency range due to divided
bobbin
High permeability for R type
• Operatingtemperaturerangefrom−25°Cto+130°Cfor
standard type
• Operatingtemperaturerangefrom−25°Cto+120°Cfor
R type
• Lowleakagemagneticuxtooutside
• UL94V–0ameretardantratedbaseandbobbin
Overview
The KEMET SSHB coils are dual mode chokes with a wide
variety of characteristics. These hybrid coils combine
the two functions of normal mode countermeasure and
common mode noise suppression in just one coil. Reducing
the number of required products ensures cost savings and
spaceeciency.Ourproprietarycorematerialsprovide
optimized solutions for high-temperature requirements
(standard type) or for high permeability needs (R type). In
addition,thespeciallydevelopedshapeisecientwith
normal noise suppression.
Applications
LED lighting
Audio-visual equipment
• Oceautomationequipment
Power supplies
AC Line Filters
Dual Mode SSHB Coils, 21HS Series,
Wide Range Impedance Type
Part Number System
SSHB 21 HS- R03 1580
Series Core Size
(mm)
Core Orientation
and Bobbin Type Core Type Rated Current AC
(A)
Inductance (mH)
Minimum
SSHB 21 = 21.0 mm HS- = Horizontal, bobbin with
sectional winding structure
Blank = Standard
R = High permeability
0x=0.xA
xx=x.xA
Examples:
03 = 0.3 A
13 = 1.3 A
xxxx=xxx.xmH
xxx=xx.x
0xx=x.xmH
Examples:
1157 = 115.7 mH
596 = 59.6 mH
024 = 2.4 mH
2© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard LF0039_SSHB21HS 3/4/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
AC Line Filters – Dual Mode SSHB Coils, 21HS Series, Wide Range Impedance Type
Magnetic Permeability of Ferrite Material
Inordertoachieveecientnoisereduction,itisimportanttoselectthematerialaccordingtothetargetfrequencyband.
Depending on its magnetic permeability, a particular ferrite material will be effective in a certain frequency band.
A schematic representation of the relationship between the magnetic permeability of each material and the corresponding
effective band range is shown in Figure 1.
Materials with higher magnetic permeability are effective in the lower frequency range, while those with lower magnetic
permeability are effective in the higher frequency range. Thus, Mn-Zn products are mainly used for reducing conduction
noise, while Ni-Zn products are commonly used for radiation noise countermeasures.
The effective frequency range varies depending on core shape, size and number of windings. This frequency dependence
ofthemagneticpermeabilityasshowninthegureservesforreferencepurposesonlyanditshouldbetestedontheactual
device to determine its effectiveness.
S18H, S15H, 10H, 7H, 5H, 1400L and 700L are KEMETs proprietary ferrite material names.
Other materials can also be available on request.
Figure 1 - Relationship between the magnetic permeability of each material and its effective frequency range
10 kHz
0
10,000
20,000
100 kHz 1 MHz 10 MHz 100 MHz 1 GHz
Effective Frequency Range
Magnetic Permeability
Ni-Zn Series
1400L
700L
S18H
S15H
10H
7H
5H
Mn-Zn Series
Lower magnetic permeability:
Higher noise suppression effect
in the higher frequency range
Higher magnetic permeability:
Higher noise suppression effect
in the lower frequency range
3© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard LF0039_SSHB21HS 3/4/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
AC Line Filters – Dual Mode SSHB Coils, 21HS Series, Wide Range Impedance Type
Core Structure
Conventional Original New Core Shape
This original shape structure allows for
optimized composite characteristics of
common mode and normal mode
noise countermeasures.
Common Mode Normal Mode
Magnetic Flux Density
Increased efficiency on normal mode inductance
Material solution for specific requirements
Standard type for high temperature needs
R type for high permeability needs
Low leakage magnetic flux to outside
Dimensions – Millimeters
N1 N2
(21.0)
(15.0)
23.0 Maximum
26.0 Maximum
15.0 ±0.521.0 ±0.5
φ0.8
15.5 Maximum
3.5 ±0.5
4© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard LF0039_SSHB21HS 3/4/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
AC Line Filters – Dual Mode SSHB Coils, 21HS Series, Wide Range Impedance Type
Environmental Compliance
All KEMET AC Line Filters are RoHS Compliant.
Table 1 – Ratings & Part Number Reference
Part Number
Rated
Current
AC (A)
Inductance
(Common) (mH)
Minimum
Inductance
(Normal) (μH)
Typical
DC Resistance/
Line (Ω)
Maximum
Temperature
Rise (K)
Maximum
Marking Weight (g)
Approximate
SSHB21HS-03656
0.3
65.6
1,832
2.95
40
03 Lot No.
14
SSHB21HS-04507
0.4
50.7
1,341
2.03
40
04 Lot No.
14
SSHB21HS-05440
0.5
44.0
1,230
1.88
55
05 Lot No.
14
SSHB21HS-06378
0.6
37.8
1,023
1.48
60
06 Lot No.
14
SSHB21HS-07267
0.7
26.7
665
1.03
55
07 Lot No.
14
SSHB21HS-08200
0.8
20.0
515
0.78
55
08 Lot No.
14
SSHB21HS-10145
1.0
14.5
384
0.57
65
10 Lot No.
14
SSHB21HS-12110
1.2
11.0
290
0.43
65
12 Lot No.
14
SSHB21HS-15064
1.5
6.4
180
0.28
65
15 Lot No.
14
SSHB21HS-18046
1.8
4.6
129
0.20
65
18 Lot No.
14
SSHB21HS-20034
2.0
3.4
96
0.14
55
20 Lot No.
14
SSHB21HS-25021
2.5
2.1
60
0.09
50
25 Lot No.
14
SSHB21HS-30013
3.0
1.3
38
0.06
45
30 Lot No.
14
SSHB21HS-R031350
0.3
135.0
1,832
2.95
40
R03 Lot No.
14
SSHB21HS-R041050
0.4
105.0
1,341
2.03
40
R04 Lot No.
14
SSHB21HS-R05910
0.5
91.0
1,230
1.88
55
R05 Lot No.
14
SSHB21HS-R06780
0.6
78.0
1,023
1.48
60
R06 Lot No.
14
SSHB21HS-R07550
0.7
55.0
665
1.03
55
R07 Lot No.
14
SSHB21HS-R08410
0.8
41.0
515
0.78
55
R08 Lot No.
14
SSHB21HS-R10300
1.0
30.0
384
0.57
65
R10 Lot No.
14
SSHB21HS-R12220
1.2
22.0
290
0.43
65
R12 Lot No.
14
SSHB21HS-R15130
1.5
13.0
180
0.28
65
R15 Lot No.
14
SSHB21HS-R18095
1.8
9.5
129
0.20
65
R18 Lot No.
14
SSHB21HS-R20071
2.0
7.1
96
0.14
55
R20 Lot No.
14
SSHB21HS-R25044
2.5
4.4
60
0.09
50
R25 Lot No.
14
SSHB21HS-R30028
3.0
2.8
38
0.06
45
R30 Lot No.
14
Performance Characteristics
Item Performance Characteristics
Rated Voltage 250 VAC
Withstanding Voltage 2,400 VAC (2 seconds, between lines)
Insulation Resistance >100MΩat500VDC(betweenlines)
Rated Current AC Range 0.3 – 3.0 A
Rated Inductance Range 1.3 – 135.0 mH minimum
Inductance Measurement Condition 10 kHz
Thermal Class E(120°C)(RType)andB(130°C)
Operating Temperature Range −25°Cto+120°C(includeselftemperaturerise)
(RType)and−25°Cto+130°C(includeselftemperaturerise)
5© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard LF0039_SSHB21HS 3/4/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
AC Line Filters – Dual Mode SSHB Coils, 21HS Series, Wide Range Impedance Type
Frequency Characteristics
SSHB21HS
6© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard LF0039_SSHB21HS 3/4/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
AC Line Filters – Dual Mode SSHB Coils, 21HS Series, Wide Range Impedance Type
Frequency Characteristics (cont’d)
SSHB10HS-R
7© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard LF0039_SSHB21HS 3/4/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
AC Line Filters – Dual Mode SSHB Coils, 21HS Series, Wide Range Impedance Type
Packaging
Type Packaging Type Pieces Per Box
SSHB21HS Tray 360
Handling Precautions
Precautions for product storage
AC Line Filters should be stored in normal working environments. While the chokes themselves are quite robust in other
environments,solderabilitywillbedegradedbyexposuretohightemperatures,highhumidity,corrosiveatmospheres,and
long term storage.
KEMETrecommendsthatmaximumstoragetemperaturenotexceed40°Candmaximumstoragehumiditynotexceed70%
relativehumidityandatmospheresshouldbefreeofchlorineandsulfurbearingcompounds.Temperatureuctuations
shouldbeminimizedtoavoidcondensationontheparts.Avoidalsostoragenearstrongmagneticeldsasthismight
magnetize the product.
For optimized solderability, AC Line Filters’ stock should be used promptly, preferably within 6 months of receipt.
Product temperature rise values
The values listed for temperature rise are the result of self-heating in wires when the rated current (commercial frequency)
is applied.
Check and evaluate the value of the core temperature rise under actual operating conditions when using.
Export Control
For customers in Japan
Forproductsthatarecontrolleditemssubjecttothe“ForeignExchangeandForeignTradeLaw”ofJapan,theexportlicense
speciedbythelawisrequiredforexport.
For customers outside Japan
AC Line Filters should not be used or sold for the use in the development, production, stockpiling or utilization of any
conventional weapons, mass-destruction weapons (nuclear, chemical, biological weapons or missiles) or any other
weapons.
8© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard LF0039_SSHB21HS 3/4/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
AC Line Filters – Dual Mode SSHB Coils, 21HS Series, Wide Range Impedance Type
KEMET Electronics Corporation Sales Offi ces
Foracompletelistofourglobalsalesoces,pleasevisitwww.kemet.com/sales.
Disclaimer
Allproductspecications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsiblefor
checkingandverifyingtheextenttowhichtheInformationcontainedinthispublicationisapplicabletoanorderatthetimetheorderisplaced.AllInformationgiven
hereinisbelievedtobeaccurateandreliable,butitispresentedwithoutguarantee,warranty,orresponsibilityofanykind,expressedorimplied.
StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET)knowledgeoftypicaloperatingconditionsforsuch
applications,butarenotintendedtoconstitute–andKEMETspecicallydisclaims–anywarrantyconcerningsuitabilityforaspeciccustomerapplicationoruse.
TheInformationisintendedforuseonlybycustomerswhohavetherequisiteexperienceandcapabilitytodeterminethecorrectproductsfortheirapplication.Any
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes
no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury
or property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other
measures may not be required.
KEMET is a registered trademark of KEMET Electronics Corporation.