INPUT CHARACTERISTICS: P1H-6350/6400P VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 HZ INPUT CURRENT: 8.0 A ( RMS ) FOR 115VAC 4.0 / 5.0 A ( RMS ) FOR 230VAC INRUSH CURRENT: 60A MAX. FOR 115 VAC 80 A MAX. FOR 230 VAC OUTPUT CHARACTERISTICS: OUTPUT VOLTAGE OUTPUT CURRENT(A) MIN. MAX. PEAK REGULATION OUTPUT LOAD LINE RIPPLE & NOISE MAX. [P-P] 5V 3.0 25 5% 1% 80mV 12V 2 28 6% 1% 120mV -5V 0 0.5 10% 1% 150mV -12V 0 0.5 10% 1% 150mV 3.3V 1.0 20 5% 1% 80mV +5VSB 0.1 2 5% 1% 80mV REMARKS: THE OUTPUT POWER OF 5V & 3.3V NOT EXCEED 175W SPECIFICATION: TEMPERATURE RANGE: OPERATING 0 --- 50 / 40 HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND EFFICIENCY: 65% TYPICAL POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms OVER LOAD PROTECTION: 110 % ~ 160 % OVER VOLTAGE PROTECTION: +5V 5.7 ~ 6.5 V, 3.3V 3.7 ~ 4.1 V +12V 13.3 ~ 14.3 V SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B SAFETY: UL 1950, CSA 22.2 NO/ 950, TUV IEC 950 REMOTE ON / OFF CONTROL THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE / ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY), AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE. 3.3V / 5V REMOTE SENSING COOLING: TWO 40mm DC FANS DIMENSION: 225 (D) x 100 (W) x 40.5 (H) mm ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D Revision: A01