Series AM1LR-NZ
1 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 051e R12.A 1 of 3 North America only
FEATURES:
Regulated output
Isolation Voltage of 1500 & 3000VDC
Continuous short circuit protection
Small SMD package
Efficiency up to 75%
Universal industry pinout
Operating temperature: -40oC to +85 oC
Models
Single output
Model
Input Voltage
(V)
Output
Voltage
(V)
Output
Current (mA)
Isolation
(VDC)
Max
Capacitive
Load (µF)
Efficiency
(%)
AM1LR-0503S-NZ 4.75-5.25 3.3 243 1500 220 58
AM1LR-0505S-NZ 4.75-5.25 5 200 1500 220 72
AM1LR-0512S-NZ 4.75-5.25 12 84 1500 220 73
AM1LR-0515S-NZ 4.75-5.25 15 67 1500 220 74
AM1LR-1205S-NZ 11.4-12.6 5 200 1500 220 73
AM1LR-1212S-NZ 11.4-12.6 12 84 1500 220 73
AM1LR-1215S-NZ 11.6-12.6 15 67 1500 220 75
AM1LR-2405S-NZ 22.8-25.2 5 200 1500 220 73
AM1LR-2412S-NZ 22.8-25.2 12 84 1500 220 73
AM1LR-2415S-NZ 22.8-25.2 15 67 1500 220 74
AM1LR-0503SH30-NZ 4.75-5.25 3.3 243 3000 220 58
AM1LR-0505SH30-NZ 4.75-5.25 5 200 3000 220 72
AM1LR-0512SH30-NZ 4.75-5.25 12 83 3000 220 73
AM1LR-0515SH30-NZ 4.75-5.25 15 67 3000 220 74
AM1LR-1205SH30-NZ 11.4-12.6 5 200 3000 220 73
AM1LR-1212SH30-NZ 11.4-12.6 12 83 3000 220 73
AM1LR-2405SH30-NZ 22.8-25.2 5 200 3000 220 73
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters Nominal Typical Maximum Units
Voltage Range
5
12
24
4.75-5.25
11.4-12.6
22.8-25.2
VDC
Absolute Max Input Voltage
(1 sec max)
5 Vin
12 Vin
24 Vin
9
18
30
VDC
Filter Capacitor
Quiescent Current
5
12
24
15
10
7
mA
Input Reflected Ripple current 15 mA
Isolation Specifications
Parameters Conditions Typical Rated Units
Tested I/O Voltage 60 sec, <1mA 1500 & 3000 VDC
Resistance 500VDC 1000 MOhm
Capacitance 20 pF
Click on Series name for product info on aimtec.com
Series AM1LR-NZ
1 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 051e R12.A 2 of 3 North America only
Output Specifications
Parameters Conditions Typical Maximum Units
Voltage Accuracy 100% load (see tolerance chart) ±3 %
Short Circuit Protection Continuous
Short Circuit Restart Auto-Recovery
Line Voltage Regulation For ±1% of Vin ±0.25 % of Vin
Load Voltage Regulation (10% - 100% Load) 3.3V
(10% - 100% Load) Other outputs
±3
±2
%
Temperature Coefficient 100% load ±0.03 %/oC
Ripple & Noise 50 mV p-p
General Specifications
Parameters Conditions Typical Maximum Units
Switching frequency 100% load 100 300 KHz
Operating temperature With derating above +71 -40 to +85 oC
Storage temperature -55 to +125 oC
Maximum Case temperature 95 oC
Cooling Free air convection
Storage Humidity Non Condensing 95 % RH
Case material Epoxy resin (UL94-V0)
Weight 2 g
Dimensions (L x W x H) 0.60 x 0.44 x 0.28inches 15.24 x 11.20 x 7.25mm
MTBF >3,500,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)hours
Maximum soldering temperature 1.5mm from case for 10 sec 300 oC
Maximum case temperature 130 oC
Pin Out Specifications Dimensions
All dimensions are in mm (inch)
All Pins are on a 2.54mm (0.10inch) pitch
with tolerance of ±0.25mm (0.01inch)
Pin Single
1 -V Input
2 +V Input
3 No Pin
4 -V Output
5 -V Output
6 No Pin
7 +V Output
8 No Pin
9 No Pin
10 N.C.
8.40
(0.33)
7.62
(0.30)
Top View
Front View
Side View
1.50
(0.06)
15.2
(0.60)
0.50
(0.02)
2.54
(0.10)
1
7.62
(0.30)
11.20
(0.44)
0.25
(0.01) ~5º angle
7.00
(0.28)
Series AM1LR-NZ
1 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 051e R12.A 3 of 3 North America only
Derating
Input Reflected Ripple Current Test Circuit
EMI Recommended Circuit (Class B)
Output Capacitor (C2)
NOTE: 1.Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
Vout
(VDC)
C2
(µF)
3.3 & 5 10
12 2.2
15 1
-40 -20 0204060
80 100
100
80
60
40
20
0
Safe Operating Area
Output Power (%)
85
Ambient Temperature
º C
Free Air Convection
71º
C
LDM
6.8µH
C1
4.7µF/
50V
DC/DC
Converter
+V input
-V input
+V output
Load
-V output
C2