Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, AC, M12, M18, M30 * Thermoplastic polyester housing, cylindrical * Diameter: M12, M18, M30 * Sensing distance: 2 to 15 mm * Power supply: 20 to 250 VAC * Output: SCR, make or break switching * Protection: Overvoltage * LED-indication for output ON * Long or short housing * 2 m cable or M12 plug (double keyed) Product Description Ordering Key AC proximity switches constructed in rugged thermoplastic polyester housings. Sizes available are M12, M18 and M30. Length of housing is selectable with 30 mm Type Housing diameter (mm) Rated operating dist. (mm) Output type Housing material Body style Plug thread or 50 mm thread. Bright LED ring utilizing a yellow LED clearly gives indication of output status. Protection rating IP 67 ensures environmental compatibility. EI 1202 TBOPL-6 Type Selection AC Types, Cable and M12 Plug Housing diameter Body style Connection Rated operating dist. (Sn) Ordering no. SCR Make switching Ordering no. SCR Break switching M12 M12 M12 M12 Long Long Long Long Cable Plug Cable Plug 2 mm 1) 2 mm 1) 4 mm 2) 4 mm 2) EI 1202 TBOPL EI 1202 TBOPL-6 EI 1204 TBOPL EI 1204 TBOPL-6 EI 1202 TBCPL EI 1202 TBCPL-6 EI 1204 TBCPL EI 1204 TBCPL-6 M18 M18 M18 M18 M18 M18 M18 M18 Short Short Long Long Short Short Long Long Cable Plug Cable Plug Cable Plug Cable Plug 5 mm 1) 5 mm 1) 5 mm 1) 5 mm 1) 8 mm 2) 8 mm 2) 8 mm 2) 8 mm 2) EI 1805 TBOPS EI 1805 TBOPS-6 EI 1805 TBOPL EI 1805 TBOPL-6 EI 1808 TBOPS EI 1808 TBOPS-6 EI 1808 TBOPL EI 1808 TBOPL-6 EI 1805 TBCPS EI 1805 TBCPS-6 EI 1805 TBCPL EI 1805 TBCPL-6 EI 1808 TBCPS EI 1808 TBCPS-6 EI 1808 TBCPL EI 1808 TBCPL-6 M30 M30 M30 M30 M30 M30 M30 M30 Short Short Long Long Short Short Long Long Cable Plug Cable Plug Cable Plug Cable Plug 10 mm 1) 10 mm 1) 10 mm 1) 10 mm 1) 15 mm 2) 15 mm 2) 15 mm 2) 15 mm 2) EI 3010 TBOPS EI 3010 TBOPS-6 EI 3010 TBOPL EI 3010 TBOPL-6 EI 3015 TBOPS EI 3015 TBOPS-6 EI 3015 TBOPL EI 3015 TBOPL-6 EI 3010 TBCPS EI 3010 TBCPS-6 EI 3010 TBCPL EI 3010 TBCPL-6 EI 3015 TBCPS EI 3015 TBCPS-6 EI 3015 TBCPL EI 3015 TBCPL-6 Short = 30 mm thread Long = 50 mm thread Make switching = Normally Open (NO) Break switching = Normally Closed (NC) 1) 2) For flush mounting in metal For non-flush mounting in metal Specifications are subject to change without notice (20.08.01) 1 EI, AC, M12, M18, M30 Specifications Rated operational volt. (Ue) (UB) Rated operational current (Ie) Continuous Short-time Minimum load current OFF-state current (Ir) Voltage drop (Ud) Protection Transient voltage Power ON delay Frequency of operating cycles (f) Indication for output ON Assured operating dist. (Sa) Repeat accuracy (R) Hysteresis (H) (Differential travel) Effective operating dist. (Sr) 24 to 240 VAC 20 to 265 VAC, 50 to 60 Hz 10 - 500 mA 2.5 A, max. 20 ms 10 mA 2 mA 8 VAC at max. load Transients Level 3, 2.5 kV, acc. to IEC 60255-5 (500 , 0.5 J) (prepared) 100 ms 25 Hz LED, yellow 0 Sa 0.81 Sn 5% 0.9 x Sr Su 1.1 x Sr Usable operating dist. (S) Ambient temperature Operating Storage Degree of protection -25 to +70C (-13 to +158F) -30 to +80C (-22 to +176F) IP 67 (Nema 1, 3, 4, 6, 13) Housing material Body Back Connection Cable Grey thermoplastic polyester Black thermoplastic polyester 2 m, 2 x 0.50 mm2 grey PVC, oil proof M12 x 1 (double keyed) CONH6A-xx EI 12 60 g EI 18 110 g EI 30 180 g EI 12 1.8 Nm EI 18 2.6 Nm EI 30 7.5 Nm UL, CSA Yes Plug Cables for plug (-6) Weight (cable excluded) Tightening torque 3 to 20% of sensing distance 0.9 x Sn Sr 1.1 x Sn Approvals CE-marking A B mm C mm Type 66 74.5 70 78.5 57 55 77 75 65 63 85 83 0 0 4 4 0 0 0 0 8 8 8 8 M 12 x 1 x 50 M 12 x 1 x 50 M 12 x 1 x 50 M 12 x 1 x 50 M 18 x 1 x 30 M 18 x 1 x 30 M 18 x 1 x 50 M 18 x 1 x 50 M 18 x 1 x 30 M 18 x 1 x 30 M 18 x 1 x 50 M 18 x 1 x 50 Dimensions Type EI 1202 TB..L EI 1202 TB..L-6 EI 1204 TB..L EI 1204 TB..L-6 EI 1805 TB..S EI 1805 TB..S-6 EI 1805 TB..L EI 1805 TB..L-6 EI 1808 TB..S EI 1808 TB..S-6 EI 1808 TB..L EI 1808 TB..L-6 EI 3010 TB..S EI 3010 TB..S-6 EI 3010 TB..L EI 3010 TB..L-6 EI 3015 TB..S EI 3015 TB..S-6 EI 3015 TB..L EI 3015 TB..L-6 A B mm C mm 59 55.5 79 75.5 71 67.5 91 87.5 0 0 0 0 12 12 12 12 M 30 x 1.5 x 30 M 30 x 1.5 x 30 M 30 x 1.5 x 50 M 30 x 1.5 x 50 M 30 x 1.5 x 30 M 30 x 1.5 x 30 M 30 x 1.5 x 50 M 30 x 1.5 x 50 A A 3 1 2 M12x1 B Cable type 2 C LED B C LED Plug type Specifications are subject to change without notice (20.08.01) EI, AC, M12, M18, M30 Wiring Diagrams 2 BN 2 BN 3 BU 3 BU TBOS TBCS Installation Hints To avoid interference from inductive voltage/ current peaks, separate the prox. switch power cables from any other power cables, e.g. motor, contactor or solenoid cables Relief of cable strain Protection of the sensing face Switch mounted on mobile carrier A proximity switch should not serve as mechanical stop Any repetitive flexing of the cable should be avoided Incorrect Correct The cable should not be pulled Power Supplies Power supplies VAC: > SS 110 Specifications are subject to change without notice (20.08.01) 3