Specifications are subject to change without notice (20.08.01) 1
Proximity Sensors Inductive
Thermoplastic Polyester Housing
Types EI, AC, M12, M18, M30
Thermoplastic polyester housing, cylindrical
Diameter: M12, M18, M30
Sensing distance: 2 to 15 mm
Power supply: 20 to 250 VAC
Output: SCR, make or break switching
•Protection: Overvoltage
LED-indication for output ON
Long or short housing
•2 m cable or M12 plug (double keyed)
Product Description
thread or 50 mm thread.
Bright LED ring utilizing a yel-
low LED clearly gives indica-
tion of output status. Protec-
tion rating IP 67 ensures envi-
ronmental compatibility.
AC proximity switches con-
structed in rugged thermo-
plastic polyester housings.
Sizes available are M12, M18
and M30. Length of housing
is selectable with 30 mm
Type
Housing diameter (mm)
Rated operating dist. (mm)
Output type
Housing material
Body style
Plug
Type Selection AC Types, Cable and M12 Plug
Housing Body Connec- Rated Ordering no. Ordering no.
diameter style tion operating SCR SCR
dist. (Sn)Make switching Break switching
M12 Long Cable 2 mm 1) EI 1202 TBOPL EI 1202 TBCPL
M12 Long Plug 2 mm 1) EI 1202 TBOPL-6 EI 1202 TBCPL-6
M12 Long Cable 4 mm 2) EI 1204 TBOPL EI 1204 TBCPL
M12 Long Plug 4 mm 2) EI 1204 TBOPL-6 EI 1204 TBCPL-6
M18 Short Cable 5 mm 1) EI 1805 TBOPS EI 1805 TBCPS
M18 Short Plug 5 mm 1) EI 1805 TBOPS-6 EI 1805 TBCPS-6
M18 Long Cable 5 mm 1) EI 1805 TBOPL EI 1805 TBCPL
M18 Long Plug 5 mm 1) EI 1805 TBOPL-6 EI 1805 TBCPL-6
M18 Short Cable 8 mm 2) EI 1808 TBOPS EI 1808 TBCPS
M18 Short Plug 8 mm 2) EI 1808 TBOPS-6 EI 1808 TBCPS-6
M18 Long Cable 8 mm 2) EI 1808 TBOPL EI 1808 TBCPL
M18 Long Plug 8 mm 2) EI 1808 TBOPL-6 EI 1808 TBCPL-6
M30 Short Cable 10 mm 1) EI 3010 TBOPS EI 3010 TBCPS
M30 Short Plug 10 mm 1) EI 3010 TBOPS-6 EI 3010 TBCPS-6
M30 Long Cable 10 mm 1) EI 3010 TBOPL EI 3010 TBCPL
M30 Long Plug 10 mm 1) EI 3010 TBOPL-6 EI 3010 TBCPL-6
M30 Short Cable 15 mm 2) EI 3015 TBOPS EI 3015 TBCPS
M30 Short Plug 15 mm 2) EI 3015 TBOPS-6 EI 3015 TBCPS-6
M30 Long Cable 15 mm 2) EI 3015 TBOPL EI 3015 TBCPL
M30 Long Plug 15 mm 2) EI 3015 TBOPL-6 EI 3015 TBCPL-6
Short = 30 mm thread
Long = 50 mm thread
Make switching = Normally Open (NO)
Break switching = Normally Closed (NC)
1) For flush mounting in metal
2) For non-flush mounting in metal
Ordering Key
EI 1202 TBOPL-6
2Specifications are subject to change without notice (20.08.01)
EI, AC, M12, M18, M30
Specifications
Rated operational volt. (Ue)24 to 240 VAC
(UB)20 to 265 VAC, 50 to 60 Hz
Rated operational current (Ie)
Continuous 10 - 500 mA
Short-time 2.5 A, max. 20 ms
Minimum load current 10 mA
OFF-state current (Ir)2 mA
Voltage drop (Ud)8 VAC at max. load
Protection Transients
Transient voltage Level 3, 2.5 kV, acc. to
IEC 60255-5 (500 , 0.5 J)
(prepared)
Power ON delay 100 ms
Frequency of operating
cycles (f) 25 Hz
Indication for output ON LED, yellow
Assured operating dist. (Sa)0 Sa0.81 Sn
Repeat accuracy (R) 5%
Hysteresis (H)
(Differential travel)
3 to 20% of sensing distance
Effective operating dist. (Sr)0.9 x SnSr1.1 x Sn
Usable operating dist. (S) 0.9 x SrSu1.1 x Sr
Ambient temperature
Operating
-25° to +70°C (-13° to +158°F)
Storage
-30° to +80°C (-22° to +176°F)
Degree of protection IP 67
(Nema 1, 3, 4, 6, 13)
Housing material
Body Grey thermoplastic polyester
Back Black thermoplastic polyester
Connection
Cable 2 m, 2 x 0.50 mm2
grey PVC, oil proof
Plug M12 x 1 (double keyed)
Cables for plug (-6) CONH6A-xx
Weight (cable excluded) EI 12 60 g
EI 18 110 g
EI 30 180 g
Tightening torque EI 12 1.8 Nm
EI 18 2.6 Nm
EI 30 7.5 Nm
Approvals UL, CSA
CE-marking Yes
Dimensions
Type A B C
mm mm
EI 1202 TB..L 66 0 M 12 x 1 x 50
EI 1202 TB..L-6 74.5 0 M 12 x 1 x 50
EI 1204 TB..L 70 4 M 12 x 1 x 50
EI 1204 TB..L-6 78.5 4 M 12 x 1 x 50
EI 1805 TB..S 57 0 M 18 x 1 x 30
EI 1805 TB..S-6 55 0 M 18 x 1 x 30
EI 1805 TB..L 77 0 M 18 x 1 x 50
EI 1805 TB..L-6 75 0 M 18 x 1 x 50
EI 1808 TB..S 65 8 M 18 x 1 x 30
EI 1808 TB..S-6 63 8 M 18 x 1 x 30
EI 1808 TB..L 85 8 M 18 x 1 x 50
EI 1808 TB..L-6 83 8 M 18 x 1 x 50
Type A B C
mm mm
EI 3010 TB..S 59 0 M 30 x 1.5 x 30
EI 3010 TB..S-6 55.5 0 M 30 x 1.5 x 30
EI 3010 TB..L 79 0 M 30 x 1.5 x 50
EI 3010 TB..L-6 75.5 0 M 30 x 1.5 x 50
EI 3015 TB..S 71 12 M 30 x 1.5 x 30
EI 3015 TB..S-6 67.5 12 M 30 x 1.5 x 30
EI 3015 TB..L 91 12 M 30 x 1.5 x 50
EI 3015 TB..L-6 87.5 12 M 30 x 1.5 x 50
Cable type
LED
A
CB
Plug type
32
1
A
LED
M12x1
CB
Specifications are subject to change without notice (20.08.01) 3
Power Supplies
Power supplies VAC: > SS 110
Wiring Diagrams
TBCS TBOS
2 BN
3 BU 3 BU
2 BN
Installation Hints
Relief of cable strain Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/
current peaks, separate the prox. switch pow-
er cables from any other power cables, e.g.
motor, contactor or solenoid cables Incorrect
Correct
The cable should not be pulled A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided
EI, AC, M12, M18, M30